PROJECT: ELECTRICITY IV ALSTOM GRID

REVISION HISTORY

Rev Date Creation / Update


00 11/22/2011 Original Issue

01 09/24/2012 Modified to take into account customer comments dated


July, 7, 2012 reference: 01/PDA/DRT-DST/2012

02 11/12/2012 Modified to take into account mail customer dated


November, 8, 2012

03 11/26/2012 Modified to take into account mail customer dated


November, 24, 2012

04 11/12/2015 Modified according to post disaster replacement

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc Page 2/17


PROJECT: ELECTRICITY IV ALSTOM GRID

Table of Contents

1. INTRODUCTION................................................................................................................. 4
2. REFERENCE DOCUMENTS .............................................................................................. 4
3. CHANGE COMPARED TO PREVIOUS REVISION........................................................... 4
4. TELEPROTECTION NETWORK – ELECTRICITY IV ....................................................... 5
4.1. Overview ..................................................................................................................... 5
4.2. Configuration.............................................................................................................. 8
4.2.1. Digital DIP Configuration ..................................................................................... 8
4.2.2. Analog DIP Configuration .................................................................................... 8
4.2.3. Integrated TPI Configuration................................................................................ 8
4.3. Configuration summary ............................................................................................ 9
4.4. Supervision................................................................................................................. 9
4.5. Bill of Quantity ......................................................................................................... 11
4.6. Spare parts ............................................................................................................... 12
5. ANNEX 1: TECHNICAL SCHEDULE ............................................................................... 13
6. ANNEX 2: E-TERRAGRIDCOM DIP BROCHURE .......................................................... 14
7. ANNEX 3: E-TERRAGRIDCOM TPI MODULE BROCHURE .......................................... 15
8. ANNEX 4: ETERRAGRIDCOM DIP TYPE TEST CERTIFICATE ................................... 16
9. ANNEX 5: ETERRAGRIDCOM TPI TYPE TEST CERTIFICATE .................................... 17

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc Page 3/17


PROJECT: ELECTRICITY IV ALSTOM GRID

1. INTRODUCTION

Two types of teleprotection equipment will be used: the first one is E-terragridcom DIP used in
analog or digital mode. The second one is the E-terragridcom TPI, teleprotection module
integrated in the Power Line Carrier. That second type of teleprotection has been introduced in
order to have 2 teleprotections equipment on the same PLC equipment.

Technical schedule, brochure and type test report are included in appendix.

2. REFERENCE DOCUMENTS

 Contract: :Transmission Package, Lot 1-Substations, section VI, Part TS1-


General technical requirements,
 Contract: :Transmission Package, Lot 1-Substations, section VI, Part TS7-
Telecommunications,
 Contract, Schedule n°1, S7-12-Lot1-Price Schedule V3,
 Lot 1 Clarification to Bidders: clarification requests Lot 1 S/S March 16 th, 2010.
 Appendix 1-EIV- Telecom Scheme Tender doc 28-10-08,
 NCC/EDM/Lot-1 Substations/PO n°004 dated 18 October 2011,
 Alstom technical offer dated 13 July 2011
 Comments from Electricidade de MOCAMBIQUE, dated July, 12, 2012, reference:
01/PDA/DRT-DST/2012.
 Mail from NCC dated August, 3, 2012
 NCC-MOZ-ELE-GEN-DRG-310-Telecom general System Description Rev 6
 NCC-MOZ-ELE-GEN-DRG-311-Telecom Network Rev 3
 PO post disaster replacement July, 2015

3. CHANGE COMPARED TO PREVIOUS REVISION

On the link Chibata – Dondo, we are now proposing 2 PLC each fitted with one TPi. In initial
offer, two PLC and 2 DIP were supplied in Chibata. One PLC (Release 5) and one DIP will be
relocated in Beira. One PLC (Release 5) and one DIP will be relocated in Dondo. The aim is to
have on the single PLC link Dondo – Beira, one DIP and one TPi link.
We provide also Two PLC link between Mavuzi & Lamego in order to maintain same number of
communication channels than originally approved and in particular two teleprotection links and
four tie lines. This is due to the fact than PLC in release 6 cannot accommodate four speech
channels.

Paragraphs 4.1, 4.2, 4.3 and 4.6 have been updated. Changes are highlighted in yellow.
NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc Page 4/17
PROJECT: ELECTRICITY IV ALSTOM GRID

4. TELEPROTECTION NETWORK – ELECTRICITY IV

4.1. Overview

The network of Electricity IV Project will interconnect the following seven substations:

 CHIBATAT 220 / 110kV


 INCHOPE
 DONDO 220 / 110kV
 MAVUZZI 110kV
 LAMEGO 110kV
 MAFAMBISSE 110kV
 BEIRA 110Kv.

These substations will be linked through an optical telecommunication network (from Chibata to
Dondo) along with Power Line Carrier (PLC) equipments.

The next paragraph describes the teleprotection equipment configuration used in the project.
This selected architecture will allow the equipment to adapt to the various transmission media
used, either through the optical network or the analogue one.

The analog teleprotection network is displayed in figure 1.

The digital teleprotection network is displayed in figure 2.

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc Page 5/17


PROJECT: ELECTRICITY IV ALSTOM GRID

Figure 1: Analog Teleprotection Network Block diagram

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc Page 6/17


PROJECT: ELECTRICITY IV ALSTOM GRID

Figure 2: Digital Teleprotection Network Block diagram

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc Page 7/17


PROJECT: ELECTRICITY IV ALSTOM GRID

4.2. Configuration
4.2.1. Digital DIP Configuration

The DIP equipment, used in digital mode, will have the following configuration:
 Number of command channels (2 contacts per command for input & output): 4
(electrical E1 interface),
 Command inputs: contact up for 24 to 250Vdc acquisition voltage: SR200 board,
 Digital transmission through SDH/PDH equipment using E1 interface (G703.6; 2
Mbps): IR173_120 daughter board of the CPU board.
 Single power supply 48 Vdc nominal input: AL137 board.
 ME50 Ethernet Board daughter board of the CPU board.

The above configuration will be applied for the following links:

 CHIBATA - DONDO (2 DIP links)


 LAMEGO – DONDO (1 DIP link).

4.2.2. Analog DIP Configuration

The DIP equipment, used in analogue mode, will have the following configuration:
 Number of command channels: 4; 2 contacts per command for input and output
 Analogue transmission through PLC using 4Wires :IR183 daughter board in CPU
board (UT148D): 4 Wires analogue interface card,
 Single tone mode,
 Single power supply 48 Vdc nominal input: AL137 board.
 ME50 Ethernet Board daughter board of the CPU board.
The above configuration will be applied for the following links:

 DONDO – BEIRA (1 DIP link).

4.2.3. Integrated TPI Configuration

The Integrated TPI, used in analogue mode, will have the following configuration:
 Number of command channels: 4.
 Analogue transmission through PLC using 4Wires,
 Single communication interface,
 TPI in QAM.
The above configuration will be applied for the following links:

 DONDO – BEIRA (1 TPI link)


 LAMEGO – MAVUZI (2 TPI link)
 CHIBATA - DONDO (2 DIP links),
 LAMEGO – DONDO (1 DIP link),

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc


Page 8/17
PROJECT: ELECTRICITY IV ALSTOM GRID

4.3. Configuration summary

The following table describes for each link the used configuration:

Link Site A Site B Number Number Number Type of


Number of of of TPI link
Analog Digital
DIP DIP
1 CHIBATA DONDO 0 2 2 CPL and
SDH (2
Mbit/s)
2 MAVUZI LAMEGO 0 0 2 CPL
3 LAMEGO DONDO 0 1 1 CPL and
SDH (2
Mbit/s)
4 DONDO BEIRA 1 0 1 CPL

4.4. Supervision

Digital DIP can supervise and control the remote side through the digital connection. The
local digital DIP is directly connected using the ME50 Ethernet board; it is then connected
to the management E-terrasentinel server either directly or through Ethernet cards
supplied in the e-DXC equipment.

The analog teleprotection links have no possibility to supervise remote ends. Therefore, for
analog teleprotection equipment co-located with e-DXC, supervision will be through
Ethernet board of e-DXC. Management information will be sent to E-terrasentinel through
e-DXC network.

For analog teleprotection equipment located in Beira and Mavuzi, ME50 board will be
connected to Lan interface of PRCS of PLC Micom T390. In that way, management
information will be transmitted through PLC LAN to LAN and then transmitted to E-
terrasentinnel server through e-DXC network.

The teleprotection supervision network is presented in the following scheme.

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc


Page 9/17
PROJECT: ELECTRICITY IV ALSTOM GRID

Figure 3: Teleprotection Management Network Block diagram

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc Page 10/17


PROJECT: ELECTRICITY IV ALSTOM GRID

4.5. Bill of Quantity

The following equipment will be provided for the project:

MAFAMBISSE 110 kV

DONDO 220/110 kV
CHIBATA 220 kV

MAVUZZI 110 kV
BEIRA 110 kV
INCHOPE

LAMEGO
Item Description Qty
1 TELEPROTECTION EQUIPMENT
1.1 DIP Analog teleprotection via PLC
-Single 48 Vdc power supply,
- 4 commands,
- 4 wire interface,
- ME50 Ethernet board.
1.2 DIP Digital teleprotection via SDH 4 1 3
-Single 48 Vdc power supply,
- 4 commands,
- 2 Mbit/s interface,
- ME50 Ethernet board.
1.3 Integrated Teleprotection Module TPi 12 2 3 4 1 2
- PLC T390 Plug in Teleprotection module with 4
independent commands

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc


Page 11/17
PROJECT: ELECTRICITY IV ALSTOM GRID

4.6. Spare parts

Two boards of each type of DIP equipment plus two integrated teleprotection modules will
be provided as spare parts for the project. They are consisting of:

Cards Quantity
Teleprotection DIP
Power supply board 1
CPU Board 1
4 command interface board I/O 1
2 Mbps G703 interface 1
4 wire interface board 1
Integrated Teleprotection Module TPi 1
- Plug in Teleprotection module with 4 independent commands

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc


Page 12/17
PROJECT: ELECTRICITY IV ALSTOM GRID

5. ANNEX 1: TECHNICAL SCHEDULE


Teleprotection :
Description Required Provided
*General
Manufacturer ALSTOM
Type reference DIP 5000 or TPI
Place of manufacture France
*Technical characteristics
Number of command channels 4 commands
Channel bandwidth Hz 4 kHz in Analogue band (DIP5000) or
integrated in QAM (TPI) in separated mode
Maximum actual transmission time
- for blocking systems ms 1ms@2048kps (digital mode), 8ms with
command channel 300-3400Hz (analogue
mode -single tone)
- for permissive tripping systems ms 1ms @2048kps,10 ms with command channel
300-3400Hz
- for direct tripping systems ms 1,5ms @2048kps, 15ms with command
channel 300-3400Hz
Dependability (i.e. probability that command is correctly
received)
- for blocking systems 10E-30 for BER 10E-3 and <6.10-4 for SNR
of 6dB (analogue)
- for permissive tripping systems 10E-35 for BER 10E-3 and <6.10-4 for SNR of
6dB (analogue)
- for direct tripping systems 10E-19 for BER 10E-3 and <6.10-4 for SNR of
6dB (analogue)
Security (i.e. probability that unwanted commends occurring)

- for blocking systems <2E-7 for BER=0,5 for digital mode (64 kps
speed) and <6.10-4 for analogue mode
- for permissive tripping systems 6E-14 for BER=0,5 for digital mode (64kbps)
and <6.10-4 for analogue mode
*for direct tripping systems
Tripping signal duration ms input filter programmable from 1 to 5ms
Transmit signal level adjustable range dB -30 + 6 dBm
Receive signal dynamic range dB -10 0 dBm
Alarm level
Transmission interface 4W 600 Ohm
Details of alarm output NO/NC contact
*Physical characteristics
Dimensions (HxWxD) mm 132mm(3U) x 483mm (19") x 307 mm
Mass kg 7,6 kg
*Environmental conditions
Standard IEC 60834-1,
IEC61000-4-2,4-3,4-4,4-5,4-6,4-8,4-12,
EN60950,
EN61010-1/60204-1/61131-2/60335-1,
EN55011/EN55022,
EN 50204/EN50082-2
Supply voltage V 24 to 250 VDC
48 VDC (36 to 60 VDC)
Operating temperature range °C -10°C/+55°C as per IEC 60068-2-1 and 60068-
2-2
Operating relative humidity range % 90% at 23°C
MTBF h 24,6 years @ 30°C
MTTR h 30 min
Programmable transmission time yes
Operation with:
- analog PLC Yes Yes
- digital multiplexed Yes Yes
Facilities of intertrip speech cut-off and command boost Yes
*Alarm
Alarm indication through LEDS and via voltage free contacts Yes
Yes
Error rate of guard or tripping signal codes too high Yes Yes
Loss of synchronization Yes Yes
Receive signal low level Yes Yes
Loss of guard signal Yes Yes
*Maintenance
Permanent self checking of link Yes Yes
Details of maintenance and configuration facilities

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc


Page 13/17
PROJECT: ELECTRICITY IV ALSTOM GRID

6. ANNEX 2: E-TERRAGRIDCOM DIP BROCHURE

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc


Page 14/17
PROJECT: ELECTRICITY IV ALSTOM GRID

7. ANNEX 3: E-TERRAGRIDCOM TPI MODULE BROCHURE

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc


Page 15/17
PROJECT: ELECTRICITY IV ALSTOM GRID

8. ANNEX 4: ETERRAGRIDCOM DIP TYPE TEST CERTIFICATE

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc


Page 16/17
PROJECT: ELECTRICITY IV ALSTOM GRID

9. ANNEX 5: ETERRAGRIDCOM TPI TYPE TEST CERTIFICATE

NCC-MOZ-ELE-GEN-DRG-304-Teleprotection System Description Rev 4.doc


Page 17/17

Das könnte Ihnen auch gefallen