Sie sind auf Seite 1von 353

ESTABLISHED IN MORE THAN 50 COUNTRIES

MORE THAN 50 YEARS OF EXPERIENCE

INDUSTRIAL and COMMERCIAL HEATING


TECHNICAL MANUAL

This document presents SBM's complete offering of gas ceramic


heating products to be used in manufacturing plants and service
industry premises.

All the functions associated with the installation of our ceramic


heaters are discussed, although the list of articles mentioned is
not exhaustive.

This manual is intended for our partners all over the world.
In it, you will find items that are not related to your specific
applications.
To know which references in the SBM catalogue are available in
your country, please consult your current SBM price list.

Please do not hesitate to contact SBM if you have any question


about our products or about this manual.

SBM - 3 Cottages de la Norge - 21490 CLENAY - FRANCE

FRANCE - Tel : 03 80 76 74 60 Fax : 03 80 76 74 69 E-mail : sbm.france@sbm.fr

INTERNATIONAL - Tel : (33) 3 80 76 74 80 Fax : (33) 3 80 76 74 89 E-mail : sbm.com@sbm.fr

Visit SBM : its technique, products, quality control


www.sbm-international.net
and international organisation.

Industrial and commercial AN_2010


SUMMARY
CERAMIC
HEATING
J

SBM 1
CERAMIC HEATING 2
SBM CATALOGUE 3
INSTALLATION 4
OPERATION 5
MAINTENANCE 6
TROUBLE-SHOOTING 7
SPARE PARTS 8
APPLICATIONS 9
TECHNICAL NOTES 10
CERAMIC
HEATING

SBM 1

1.1- SBM

1.2- SBM ISO 9001 CERTIFICATE OF QUALITY

1.3- COUNTRIES OF DISTRIBUTION

- Return to SUMMARY -
1- SBM
1.1- SBM

INTERNATIONAL CERTIFICATION
Certified ISO 9001-2008, SBM has committed to a rigorous policy of continuous
improvement for its customer satisfaction.
Our policy applies to all products that we manufacture, as well as to all related
services that we propose.
This “system” and “service” vision makes SBM a performing company, on which
its commercial partners can rely in all confidence.
1- SBM
1.2- SBM ISO 9001 CERTIFICATE OF QUALITY
1- SBM
1.3- COUNTRIES OF DISTRIBUTION

SBM radiant heaters are currently marketed in the following countries :

COUNTRIES SX M KOMFORT
(see 3.1.1) (see 3.1.5) (see 3.1.3)
SOUTH AFRICA IE IE -
GERMANY DE CE DE
AUSTRALIA AU AU -
AUSTRIA AT CE -
BELGIUM BE CE -
BULGARIA BG - -
CROATIA HR - -
DENMARK DK CE -
SPAIN ES CE -
ESTONIA EE -
FINLAND FI CE -
FRANCE FR CE -
GREAT BRITAIN GB/IRL CE -
HUNGARY HU - -
IRELAND GB/IRL CE -
ISRAEL IE - -
ITALY IT CE -
JAPAN IE - JA - -
LITHUANIA LT -
NORWAY NO - -
NEW ZEALAND AU AU -
NETHERLANDS NL CE -
POLAND PL - -
PORTUGAL PT CE -
MACEDONIA IE IE -
PEOPLE'S REPUBLIC OF CHINA IE - FR - -
CZECH REPUBLIC CZ - -
ROMANIA RO - -
RUSSIA RU RU -
SLOVAKIA SK - -
SLOVENIA SI - -
SWEDEN SE CE -
SWITZERLAND CH CH -
TURKEY TR - -
UKRAINE UA - -

For more details, please contact your SBM agent or distributor.


1- SBM
1.3.1- CE CERTIFICATES

From 1 January 1996, the CE certification for radiant heaters is mandatory


in all the countries of the European Community.
SBM has fulfilled these requirements and obtained CE marking for its
ceramic radiant heaters.

As a result, the use of SBM ceramic heaters in all buildings conforms to


current safety regulations.

Next pages :

- CE type examination certificates nr 1312AP230, 1312AP231,


1312AP232, 1312AP233 et 1312AP249.

- CE approval of quality system nr A.Q.F. 0027.


1- SBM
1.3.1.1- CE TYPE EXAMINATION CERTIFICATE N° 1312AP230
1- SBM
1.3.1.2- CE TYPE EXAMINATION CERTIFICATE NR 1312AP231
1- SBM
1.3.1.3- CE TYPE EXAMINATION CERTIFICATE NR 1312AP232
1- SBM
1.3.1.4- CE TYPE EXAMINATION CERTIFICATE NR 1312AP233
1- SBM
1.3.1.5- CE TYPE EXAMINATION CERTIFICATE NR 1312AP249
1- SBM
1.3.1.6- CE APPROVAL OF QUALITY SYSTEM NR A.Q.F. 0027
CERAMIC
HEATING

CERAMIC HEATING 2

2.1- INFRA-RED

2.2- CERAMIC HEATING

2.3- CERAMIC HEATERS

- Return to SUMMARY -
2- CERAMIC HEATING
2.1- INFRA-RED

2.1.1- GENERAL

Infra-red uses the same type of electromagnetic rays as light.

It travels in a straight line.

It is not absorbed by air.

It is absorbed by objects in which it is converted into heat.

The rays used to heat buildings falls within a range of wavelengths from
2,5 µ to 6 µ inclusive.

ELECTROMAGNETIC RAYS (wavelengths in µ)


1 µ=10-6 m - 1 cm = 10 000 µ

A
0,0136 0,4 0,76 1 2 2,5 6 10 100 400

Visible ultraviolet Hertzian

Radiant
heating

Infrared

Solar

2.1.2- HEAT RAYS EMITTED BY SBM CERAMIC HEATERS

SBM ceramic heaters have an emitting surface heated to approx. 900°C.

SBM ceramic heaters emit rays with a wavelength of approx. 2.5 µ.

There is no health risk from emission at this temperature


because it does not contain ultraviolet rays.
2- CERAMIC HEATING
2.2- CERAMIC HEATING

Ceramic heaters are "long-range" emitters. The ceramic surface of the heaters is
heated by gas combustion and emits rays in the form of energy converted into heat
by the objects in their path. This type of emission is called "infra-red".
It is invisible and is found just next to visible red in the solar spectrum.

2.2.1- INFRA-RED RAYS

Useful heating :

ƒ Ceramic infra-red rays produce heat within the objects they meet.

ƒ Ceramic infra-red rays concentrate heat where it is needed.

ƒ Ceramic infra-red rays propagate naturally in the chosen direction,


without losing transmission energy.

CERAMIC HEAT CONVENTIONAL HEAT (warm air)


Heat directed where needed Considerable heat loss at ceiling level

ƒ With ceramic infra-red heating, the air temperature is lower than the
comfort level temperature.

ƒ Ceramic infra-red heating is instantaneous, and therefore the comfort


level temperature is reached very rapidly.

ƒ As ceramic infra-red heating uses no moving mechanical part, it is silent,


and does not create draughts or dust movements.

ƒ Ceramic infra-red heating does not overheat the upper parts of the
buiding, and losses due to air renewal are greatly reduced.
2- CERAMIC HEATING
2.2.2- CERAMIC

Resistant and robust :

Ceramic has a high infra-red efficiency.


The characteristic honeycomb pattern and
the seven outlets of each "Turbo-Jet" keep
the combustion inside the ceramic,
increasing the surface temperature as well
as the infra-red heat emission.

2.2.3- INSTANT HEAT

Required
temperature
Quicker heat in the morning :
effective
use of the area
The required temperature is reached
extremely rapidly.
As inertia is low, efficiency is immediate.
energy
saving

Conventional Ceramic Time


heating heating

2.2.4- MULTIPLE SOURCES

Evenly distributed heat :

Compact ceramic heaters have an even


surface temperature. Arrangement in
"cross fields" enables uniform comfort to be
obtained throughout the heated area.

2.2.5- ZONE HEATING

Energy savings : packaging +15°C


Monday-Friday
8/12 am - 2/6 pm storage
The possibility of zone heating, +4°C
manufacturing
selection of temperatures by area, and +17°C
programming of operating times enables Monday-Friday
8/12 am - 2/6 pm dispatch
optimum use of the energy. +17°C
Monday-Friday
offices 8 am – 5 pm
2- CERAMIC HEATING
2.3- CERAMIC HEATERS

2.3.1- OPERATING PRINCIPLE

Air

Mixing
Gas

Air

Combustion surface (900°C)

2.3.2- COMBUSTION AND ENVIRONMENT

- SBM ceramic heaters are admitted to class 4 (the best) of standard EN 419-1
with regard to NOX emissions (100 mg / kWh maximum).

- SBM ceramic heaters are admitted to class 2 (the best) of standard EN 419-2
with regard to radiant efficiency (higher than 50%).

- According to European standard EN 13410, an air renewal of 10 m3/h per kW of


operating heat input is sufficient to ensure optimal hygiene conditions in the
premises.
In most cases, the existing ventilation is perfectly adequate to meet these
requirements. Evacuating the combustion gases through a flue system is
unnecessary, and no additional openings need to be added (no risk of altering
watertightness of the building construction).

- SBM ceramic heaters do not cause any air movement in the premises
(advantage in dusty atmospheres and in the case of work carried out in controlled
atmospheres).

- SBM ceramic heaters are silent (no mechanical moving parts).


2- CERAMIC HEATING
2.3.3- ENERGY SAVINGS

30 to 40 % compared to conventional heating equipment.

Direct heating without heat transfer fluids (air, steam, water or oil) generates significant
energy savings:

- No losses via gases.

- No losses in heat exchangers.

- Infra-red rays are directed downwards.

- Temperature rises quickly (95% of emitted capacity reached within 5 mins), so the
heating can be turned on just before it is needed.

- Temperature reduced during inactive periods.

- Possibility to heat specific areas at different times and temperatures.

- No electricity used by ceramic heaters after the ignition cycle.

2.3.4- LIFE-TIME

- SBM ceramic heaters are made of quality ceramic, stainless steel and brass (no
fragile surface coating).

- There are no mechanical moving part (no wear).

- SBM ceramic heaters use an ignition system that is unaffected by electric


interference. They remain switched on for 45 seconds only during each ignition
cycle.
2- CERAMIC HEATING
2.3.5- SAFETY

GAS

M radiant heater SX or KOMFORT


"single speed" radiant heater

Individual safety shut-off


for each speed

2 SX or 2 KOMFORT
"double speed" radiant heater

ELECTRICITY

Individual fuse for


each speed

2 fuse protected outputs 1 fuse protected output


2- CERAMIC HEATING
2.3.6- EASE OF INSTALLATION

SBM ceramic heaters are light and compact :

- The framework of the building does not need to be reinforced to accomodate them.

- No significant lifting equipment needed for installation.

B20SX B24SX B32SX


Model B6SX B8SX B10SX B12SX B16SX B48-2SX B64-2SX
B20-2SX B24-2SX B32-2SX
Weight (kg) 2.5 2.9 3.1 3.4 4.1 5.0 5.5 6.7 9.4 12.2

SBM ceramic heaters are fitted into the framework of the building or below the
travelling crane rails :

- No space used up on the floor.

- No engine room (boiler) required.

- No risk of damage due to direct mechanical impact.


CERAMIC
HEATING

SBM CATALOGUE 3

3.1- CERAMIC HEATERS

3.2- CONTROL MODULES

3.3- ACCESSORIES

To know which references in the SBM catalogue are available in your country, please
consult your current SBM price list.

- Return to SUMMARY -
3- SBM CATALOGUE
3.1- CERAMIC HEATERS
3.1.1- GENERAL SPECIFICATIONS OF "SX" AUTOMATIC HEATERS

B 6 SX ......................................... 3.1.1.1

B 8 SX ......................................... 3.1.1.2

B 10 SX ....................................... 3.1.1.3

B 12 SX ....................................... 3.1.1.4

B 16 SX ....................................... 3.1.1.5

B 20 SX ....................................... 3.1.1.6

B 20-2 SX .................................... 3.1.1.7


3- SBM CATALOGUE

B 24 SX ....................................... 3.1.1.8

B 24-2 SX .................................... 3.1.1.9

B 32 SX ..................................... 3.1.1.10

B 32-2 SX .................................. 3.1.1.11

B 48-2 SX .................................. 3.1.1.12


3- SBM CATALOGUE

B 64-2 SX .................................. 3.1.1.13

Related sections :

Control modules .........................................................................3.2


Accessories ................................................................................3.3
Installation......................................................................................4
Operation........................................................................................5
Maintenance ...................................................................................6
Trouble-shooting ...........................................................................7
Spare parts.....................................................................................8
Applications ...................................................................................9
3- SBM CATALOGUE
3.1.1.1- B 6 SX

CONTENTS OF INDIVIDUAL BOX

Weight : 2.50 kg 186

147 172

202 222

Dimensions in mm. 318

Other
Power supply
specifications for
Power supply :
230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory different countries
Comsumption :
0.1A (see 3.1.2)
Individual fuse :
1 fuse 0.25A (RP3) not included Australia
Ignition cycle length :
45 seconds Austria
2 Belgium
Connection 1 prewired plug, length 1m - 3 x 0.75mm included
: Bulgaria
Fixing Croatia
Czech Republic
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.
Denmark
26 26 Estonia
Finland
France
G. Britain / Ireland
Germany
Hungary
or International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Gas connection Norway
Poland
Gas inlet connection : G1/2" cylindrical male or R1/2" conical male - see (3.1.2) Portugal
Romania
Russia
ISO 228/1 - G 1/2 ISO 7/1 - R 1/2 Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.1.2- B 8 SX

CONTENTS OF INDIVIDUAL BOX

Weight : 2.90 kg 218

147 172

202 285
382
Dimensions in mm.

Other
Power supply specifications for
Power supply :
230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory different countries
Comsumption :
0.1A (see 3.1.2)
Individual fuse :
1 fuse 0.25A (RP3) not included Australia
Austria
Ignition cycle length :
45 seconds Belgium
2
Connection 1 prewired plug, length 1m - 3 x 0.75mm included
: Bulgaria
Croatia
Fixing Czech Republic
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. Denmark
26 Estonia
26
Finland
France
G. Britain / Ireland
Germany
Hungary
or International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Norway
Gas connection Poland
Gas inlet connection : G1/2" cylindrical male or R1/2" conical male - see (3.1.2) Portugal
Romania
Russia
ISO 228/1 - G 1/2 ISO 7/1 - R 1/2 Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.1.3- B 10 SX

CONTENTS OF INDIVIDUAL BOX

Weight : 3.10 kg 243

147 172

202 334
431
Dimensions in mm.

Power supply Other


Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory specifications for
Comsumption : 0.1A different countries
(see 3.1.2)
Individual fuse : 1 fuse 0.25A (RP3) not included
Australia
Ignition cycle length : 45 seconds Austria
2
Connection : 1 prewired plug, length 1m - 3 x 0.75mm included Belgium
Bulgaria
Fixing Croatia
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. Czech Republic
Denmark
26 26 Estonia
Finland
France
G. Britain / Ireland
Germany
or Hungary
International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Gas connection Norway
Gas inlet connection : G1/2" cylindrical male or R1/2" conical male - see (3.1.2) Poland
Portugal
Romania
ISO 228/1 - G 1/2 ISO 7/1 - R 1/2 Russia
Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.1.4- B 12 SX

CONTENTS OF INDIVIDUAL BOX

Weight : 3.40 kg 281

147 172

202 411
508
Dimensions in mm.

Power supply Other


Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory specifications for
Comsumption : 0.1A different countries
(see 3.1.2)
Individual fuse : 1 fuse 0.25A (RP3) not included
Australia
Ignition cycle length : 45 seconds Austria
2
Connection : 1 prewired plug, length 1m - 3 x 0.75mm included Belgium
Bulgaria
Fixing Croatia
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. Czech Republic
Denmark
26 26 Estonia
Finland
France
G. Britain / Ireland
Germany
or Hungary
International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Gas connection Norway
Gas inlet connection : G1/2" cylindrical male or R1/2" conical male - see (3.1.2) Poland
Portugal
Romania
ISO 228/1 - G 1/2 ISO 7/1 - R 1/2 Russia
Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.1.5- B 16 SX

CONTENTS OF INDIVIDUAL BOX

Weight : 4.10 kg 299

147 172

202 536
632
Dimensions in mm.

Power supply Other


Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory specifications for
Comsumption : 0.1A different countries
(see 3.1.2)
Individual fuse : 1 fuse 0.25A (RP3) not included
Australia
Ignition cycle length : 45 seconds Austria
2
Connection : 1 prewired plug, length 1m - 3 x 0.75mm included Belgium
Bulgaria
Fixing Croatia
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. Czech Republic
Denmark
26 26 Estonia
Finland
France
G. Britain / Ireland
Germany
or Hungary
International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Gas connection Norway
Gas inlet connection : G1/2" cylindrical male - or R1/2" conical male - see (3.1.2) Poland
Portugal
Romania
ISO 228/1 - G 1/2 ISO 7/1 - R 1/2 Russia
Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.1.6- B 20 SX

CONTENTS OF INDIVIDUAL BOX

Weight : 5.00 kg 243

147 172

332 334
431
Dimensions in mm.

Power supply Other


Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory specifications for
Comsumption : 0.1A different countries
(see 3.1.2)
Individual fuse : 1 fuse 0.25A (RP3) not included
Australia
Ignition cycle length : 45 seconds Austria
2
Connection : 1 prewired plug, length 1m - 3 x 0.75mm included Belgium
Bulgaria
Fixing Croatia
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. Czech Republic
26 Estonia
Denmark
Finland
France
26 G. Britain / Ireland
Germany
or Hungary
International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Gas connection Norway
Gas inlet connection : G1/2" cylindrical male or R1/2" conical male - see (3.1.2) Poland
Portugal
Romania
ISO 228/1 - G 1/2
ISO 7/1 - R 1/2 Russia
Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.1.7- B 20-2 SX

CONTENTS OF INDIVIDUAL BOX

2X

Weight : 5.00 kg 243

147 172

332 334
431
Dimensions in mm.

Power supply Other


Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory specifications for
Comsumption : 2 x 0.1A different countries
(see 3.1.2)
Individual fuse : 2 fuses 0.25A (RP32) not included
Australia
Ignition cycle length : 45 seconds Austria
2
Connection : 2 prewired plugs, length 1m - 3 x 0.75mm included Belgium
Bulgaria
Fixing Croatia
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. Czech Republic
26 Denmark
Estonia
Finland
France
26 G. Britain / Ireland
Germany
or Hungary
International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Gas connection Norway
2 gas inlet connections : G1/2" cylindrical male or R1/2" conical male - see (3.1.2) Poland
Portugal
Romania
ISO 228/1 - G 1/2
ISO 7/1 - R 1/2 Russia
Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.1.8- B 24 SX

CONTENTS OF INDIVIDUAL BOX

Weight : 5.50 kg 281

147 172

332 411
508
Dimensions in mm.

Power supply Other


Power supply :
230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory specifications for
different countries
Comsumption :
0.1A (see 3.1.2)
Individual fuse :
1 fuse 0.25A (RP3) not included Australia
Ignition cycle length :
45 seconds Austria
Connection
2
1 prewired plug, length 1m - 3 x 0.75mm included
: Belgium
Bulgaria
Fixing Croatia
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. Czech Republic
Denmark
26 Estonia
Finland
France
26 G. Britain / Ireland
Germany
Hungary
or
International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Gas connection Norway
Poland
Gas inlet connection : G1/2" cylindrical male or R1/2" conical male - see (3.1.2)
Portugal
Romania
ISO 228/1 - G 1/2 Russia
ISO 7/1 - R 1/2 Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.1.9- B 24-2 SX

CONTENTS OF INDIVIDUAL BOX

2X

Weight : 5.50 kg 281

147 172

332 411
508
Dimensions in mm.

Power supply Other


Power supply :
230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory specifications for
different countries
Comsumption :
2 x 0.1A (see 3.1.2)
Individual fuse :
2 fuses 0.25A (RP32) not included Australia
Ignition cycle length :
45 seconds Austria
Connection
2
2 prewired plugs, length 1m - 3 x 0.75mm included
: Belgium
Bulgaria
Fixing Croatia
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. Czech Republic
Denmark
26 Estonia
Finland
France
26 G. Britain / Ireland
Germany
Hungary
or
International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Norway
Gas connection
Poland
2 gas inlet connections : G1/2" cylindrical male or R1/2" conical male - see (3.1.2) Portugal
Romania
ISO 228/1 - G 1/2 Russia
ISO 7/1 - R 1/2 Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.1.10- B 32 SX

CONTENTS OF INDIVIDUAL BOX

Weight : 6.70 kg 299

147 172

332 536
632
Dimensions in mm.

Power supply Other


Power supply :
230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory specifications for
different countries
Comsumption :
0.1A (see 3.1.2)
Individual fuse :
1 fuse 0.25A (RP3) not included Australia
Ignition cycle length :
45 seconds Austria
Connection
2
1 prewired plug, length 1m - 3 x 0.75mm included
: Belgium
Bulgaria
Fixing Croatia
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. Czech Republic
Denmark
26 Estonia
Finland
France
26 G. Britain / Ireland
Germany
Hungary
or
International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Norway
Gas connection
Poland
Gas inlet connection : G1/2" cylindrical male or R1/2" conical male - see (3.1.2) Portugal
Romania
ISO 228/1 - G 1/2 Russia
ISO 7/1 - R 1/2 Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.1.11- B 32-2 SX

CONTENTS OF INDIVIDUAL BOX

2X

Weight : 6.70 kg 299

147 172

332 536
632
Dimensions in mm.

Power supply Other


Power supply :
230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory specifications for
different countries
Comsumption :
2 x 0.1A (see 3.1.2)
Individual fuse :
2 fuses 0.25A (RP32) not included Australia
Ignition cycle length :
45 seconds Austria
Connection
2
2 prewired plugs, length 1m - 3 x 0.75mm included
: Belgium
Bulgaria
Fixing Croatia
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. Czech Republic
Denmark
26 Estonia
Finland
France
26 G. Britain / Ireland
Germany
Hungary
or
International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Gas connection Norway
Poland
2 gas inlet connections : G1/2" cylindrical male or R1/2" conical male - see (3.1.2)
Portugal
Romania
ISO 228/1 - G 1/2 Russia
ISO 7/1 - R 1/2 Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.1.12- B 48-2 SX

CONTENTS OF INDIVIDUAL BOX

2X

Weight : 9.40 kg 299

147 172

463 536
632
Dimensions in mm.

Other
Power supply specifications for
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory different countries
(see 3.1.2)
Comsumption : 2 x 0.1A Australia
Individual fuse : 2 fuses 0.25A (RP32) not included Austria
Ignition cycle length : 45 seconds Belgium
2 Bulgaria
Connection : 2 prewired plugs, length 1m - 3 x 0.75mm included
Croatia
Fixing Czech Republic
26 Denmark
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.
Estonia
Finland
26 France
G. Britain / Ireland
or Germany
Hungary
International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Gas connection Norway
Poland
2 gas inlet connections : G1/2" cylindrical male or R1/2" conical male - see (3.1.2)
Portugal
Romania
ISO 228/1 - G 1/2 Russia
ISO 7/1 - R 1/2 Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.1.13- B 64-2 SX

CONTENTS OF INDIVIDUAL BOX

2X

272 Weight : 12.20 kg 299

147 172

604 536
632
Dimensions in mm.

Power supply Other


Power supply :
230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory specifications for
different countries
Comsumption :
2 x 0.1A (see 3.1.2)
Individual fuse :
2 fuses 0.25A (RP32) not included Australia
Ignition cycle length :
45 seconds Austria
Connection
2
2 prewired plugs, length 1m - 3 x 0.75mm included
: Belgium
Bulgaria
Fixing Croatia
2 directional brackets for fixing on steel tube 3/4" or square profile 25 x 25 mm. Czech Republic
Denmark
26 Estonia
Finland
France
G. Britain / Ireland
Germany
26 Hungary
or
International
Italy
Japan
Fixing : see (4.5) Lithuania
Netherlands
Norway
Gas connection
Poland
2 gas inlet connections : G1/2" cylindrical male or R1/2" conical male - see (3.1.2) Portugal
Romania
ISO 228/1 - G 1/2 Russia
ISO 7/1 - R 1/2 Slovakia
Slovenia
Spain
Sweden
Switzerland
Turkey
Ukraine
3- SBM CATALOGUE
3.1.2- SPECIFICATIONS OF "SX" AUTOMATIC HEATERS

Countries of distribution with CE marking


GERMANY B ... SX DE ................... 3.1.2.1
AUSTRIA B ... SX AT ................... 3.1.2.2
BELGIUM B ... SX BE ................... 3.1.2.3
DENMARK B ... SX DK ................... 3.1.2.4
SPAIN B ... SX ES ................... 3.1.2.5
FINLAND B ... SX FI ..................... 3.1.2.6
FRANCE B ... SX FR ................... 3.1.2.7
G.BRITAIN / IRELAND B ... SX GB/IRL ............ 3.1.2.8
ITALY B ... SX IT ..................... 3.1.2.9
NORWAY B ... SX NO................. 3.1.2.10
NETHERLANDS B ... SX NL ................. 3.1.2.11
PORTUGAL B ... SX PT.................. 3.1.2.12
SWEDEN B ... SX SE ................. 3.1.2.13
BULGARIA B ... SX BG................. 3.1.2.15
HUNGARY B ... SX HU ................. 3.1.2.17
POLAND B ... SX PL.................. 3.1.2.20
CZECH REPUBLIC B ... SX CZ ................. 3.1.2.21
ROMANIA B ... SX RO................. 3.1.2.22
SLOVAKIA B ... SX SK ................. 3.1.2.23
SLOVENIA B ... SX SI................... 3.1.2.24
TURKEY B ... SX TR ................. 3.1.2.26
ESTONIA B ... SX EE ................. 3.1.2.29
LITHUANIA B ... SX LT.................. 3.1.2.30

Other countries of distribution


AUSTRALIA / N. ZEALAND B ... SX AU ................. 3.1.2.14
CROATIA B ... SX HR ................. 3.1.2.16
INTERNATIONAL B ... SX IE................... 3.1.2.18
JAPAN B ... SX JA.................. 3.1.2.19
SWITZERLAND B ... SX CH ................. 3.1.2.25
RUSSIA B ... SX RU ................. 3.1.2.27
UKRAINE B ... SX UA ................. 3.1.2.28
3- SBM CATALOGUE
3.1.2.1- B ... SX DE (GERMANY)
B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas: G20 (natural gas type H) Category : I2ELL DE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
(3) ΣQn (Hs) (kW) 2.80 3.65 4.25 5.65 7.50 8.45 8.45 11.35 11.35 15.00 15.00 22.50 30.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G25 (natural gas type L) Category : I2ELL DE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
(3) ΣQn (Hs) (kW) 2.80 3.65 4.25 5.65 7.50 8.45 8.45 11.35 11.35 15.00 15.00 22.50 30.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 12.0 10.0 10.5 15.5 14.0 10.5 10.5 15.5 15.5 14.5 14.0 (See B) 14.5
(5) Volumetric flow rate
3
V (m /h) 0.310 0.405 0.470 0.630 0.830 0.935 0.935 1.255 1.255 1.660 1.660 2.490 3.325
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 185 195 280 - 280 2 x 195 500 2 x 280 - - (See A) -
Orifice (injector) 150 185 190 200 235 2 x 190 2 x 190 2 x 200 2 x 200 2 x 235 2 x 235 (See A) 4 x 235
3
Combustion air (m /h) 2.60 3.40 3.80 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G30/G31 (propane) Category : I3B/P DE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.80 3.80 4.25 5.80 7.00 8.50 8.50 11.60 11.60 14.00 14.00 21.00 28.00
(3) ΣQn (Hs) (kW) 3.05 4.10 4.60 6.25 7.55 9.20 9.20 12.55 12.55 15.15 15.15 22.70 30.30
Inlet pressure
p (mbar) 50
(4) Injection pressure
(mbar) 37.0 30.0 34.0 36.0 44.0 34.0 34.0 36.0 36.0 44.0 44.0 (See B) 44.0
(6) Mass flow rate
M (kg/h) 0.220 0.300 0.335 0.455 0.550 0.665 0.665 0.910 0.910 1.100 1.100 1.650 2.200
Ø orifices (1/100 mm)
Primary orifice (restrictor) 100 110 130 155 210 180 2 x 130 210 2 x 155 280 2 x 210 (See A) 2 x 280
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.60 3.60 4.00 5.40 6.50 7.90 7.90 10.80 10.80 13.00 13.00 19.50 26.00
Required air renewal
3
(m /h) 28 38 42.5 58 70 85 85 116 116 140 140 210 280

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(3) Hs = Gross calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

... / ...
3- SBM CATALOGUE
... / ...

Prim. orif. : - Prim. orif. : 320


G20
Orif. : 2 x 195 Orif. : 195
Prim. orif. : - Prim. orif. : -
A G25
Orif. : 2 x 235 Orif. : 235
Prim. orif. : 280 Prim. orif. : 210
G30/G31
Orif. : 2 x 130 Orif. : 130

B48-2SX

G20 16.7 mbar 16.7 mbar

B G25 14.5 mbar 14.0 mbar

G30/G31 44.0 mbar 44.0 mbar


3- SBM CATALOGUE
3.1.2.2- B ... SX AT (AUSTRIA)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H AT


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
(3) ΣQn (Hs) (kW) 2.80 3.65 4.25 5.65 7.50 8.45 8.45 11.35 11.35 15.00 15.00 22.50 30.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G30/G31 (propane) Category : I3B/P AT


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.80 3.80 4.25 5.80 7.00 8.50 8.50 11.60 11.60 14.00 14.00 21.00 28.00
(3) ΣQn (Hs) (kW) 3.05 4.10 4.60 6.25 7.55 9.20 9.20 12.55 12.55 15.15 15.15 22.70 30.30
Inlet pressure
p (mbar) 50
(4) Injection pressure
(mbar) 37.0 30.0 34.0 36.0 44.0 34.0 34.0 36.0 36.0 44.0 44.0 (See B) 44.0
(6) Mass flow rate
M (kg/h) 0.220 0.300 0.335 0.455 0.550 0.665 0.665 0.910 0.910 1.100 1.100 1.650 2.200
Ø orifices (1/100 mm)
Primary orifice (restrictor) 100 110 130 155 210 180 2 x 130 210 2 x 155 280 2 x 210 (See A) 2 x 280
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.60 3.60 4.00 5.40 6.50 7.90 7.90 10.80 10.80 13.00 13.00 19.50 26.00
Required air renewal
3
(m /h) 28 38 42.5 58 70 85 85 116 116 140 140 210 280

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(3) Hs = Gross calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

As the heaters are supplied without pre-wired plug, please order


"PREWIRED PLUG 1M/3FT" separately (see 8.1.3)

G30/G31 G20

B48-2SX 44.0 mbar 16.7 mbar

A 44.0 mbar 16.7 mbar

G30/G31 G20 B
Prim. orif. : 280 Prim. orif. : -
Orif. : 2 x 130 Orif. : 2 x 195
Prim. orif. : 210 Prim. orif. : 320
Orif. : 130 Orif. : 195
3- SBM CATALOGUE
3.1.2.3- B ... SX BE (BELGIUM)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20/G25 (natural gas) Category : I2E+ BE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20 (G20) / 25 (G25)
(4) Injection pressure
G20/ (mbar) 13.0/ 11.0/ 12.0/ 15.0/ 16.7/ 12.0/ 12.0/ 15.0/ 15.0/ 16.7/ 16.7/ 16.7/
(See B)
G25 (mbar) 16.0 14.0 16.0 18.0 21.0 16.0 16.0 18.0 18.0 21.0 21.0 21.0
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P BE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure 37
p (mbar)
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28.0 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18..90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G31 G20

B48-2SX 34.0 mbar 16.7 / 21 mbar

A 37.0 mbar 16.7 / 21 mbar

G31 G20 B
Prim. orif. : 370 Prim. orif. : -
Orif. : 2 x 135 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 135 Orif. : 195
3- SBM CATALOGUE
3.1.2.4- B ... SX DK (DENMARK)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H DK


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 27.00 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal see local regulations

Gas : G30/G31 (propane) Category : I3B/P DK


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.40 3.80 4.10 5.10 5.90 8.20 8.20 10.20 10.20 11.80 11.80 17.70 23.60
Inlet pressure
p (mbar) 30
(4) Injection pressure
(mbar) 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 (See B) 30.0
(6) Mass flow rate
M (kg/h) 0.190 0.300 0.320 0.400 0.460 0.640 0.640 0.800 0.800 0.920 0.920 1.380 1.845
Ø orifices (1/100 mm)
Primary orifice (restrictor) - - - - - - - - - - - (See A) -
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.20 3.50 3.80 4.70 5.40 7.60 7.60 9.40 9.40 10.90 10.90 16.30 21.80
Required air renewal see local regulations

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G30/G31 G20

B48-2SX 30.0 mbar 16.7 mbar

A 30.0 mbar 16.7 mbar

G30/G31 G20 B
Prim. orif. : - Prim. orif. : -
Orif. : 2 x 130 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 130 Orif. : 195
3- SBM CATALOGUE
3.1.2.5- B ... SX ES (SPAIN)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H ES


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P ES


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28.0 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G31 G20

B48-2SX 34.0 mbar 16.7 mbar

A 37.0 mbar 16.7 mbar

G31 G20 B
Prim. orif. : 370 Prim. orif. : -
Orif. : 2 x 135 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 135 Orif. : 195
3- SBM CATALOGUE
3.1.2.6- B ... SX FI (FINLAND)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H FI


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P FI


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G31 G20

B48-2SX 34.0 mbar 16.7 mbar

A 37.0 mbar 16.7 mbar

G31 G20 B
Prim. orif. : 370 Prim. orif. : -
Orif. : 2 x 135 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 135 Orif. : 195
3- SBM CATALOGUE
3.1.2.7- B ... SX FR (FRANCE)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
CE certificate number 1312AP 1312AP 1312AP 1312AP 1312AP
1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2Esi FR


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G25 (natural gas type L) Category : I2Esi FR


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 25
(4) Injection pressure
(mbar) 12.0 10.0 10.5 15.5 13.0 10.5 10.5 15.5 15.5 13.0 13.0 (See B) 13.0
(5) Volumetric flow rate
3
V (m /h) 0.310 0.400 0.470 0.630 0.830 0.940 0.940 1.260 1.260 1.660 1.660 2.490 3.320
Ø orifices (1/100 mm)
Primary orifice (restrictor) 160 180 185 220 250 250 2 x 185 340 2 x 220 370 2 x 250 (See A) 2 x 370
Orifice (injector) 150 185 190 200 235 2 x 190 2 x 190 2 x 200 2 x 200 2 x 235 2 x 235 (See A) 4 x 235
3
Combustion air (m /h) 2.60 3.40 4.00 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 27.90
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P FR


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28.0 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

... / ...
3- SBM CATALOGUE
... / ...

Prim. orif. : - Prim. orif. : 320


G20
Orif. : 2 x 195 Orif. : 195
Prim. orif. : 370 Prim. orif. : 250
A G25
Orif. : 2 x 235 Orif. : 235
Prim. orif. : 370 Prim. orif. : -
G31
Orif. : 2 x 135 Orif. : 135

B48-2SX

G20 16.7 mbar 16.7 mbar

B G25 13.0 mbar 13.0 mbar

G31 34.0 mbar 37.0 mbar


3- SBM CATALOGUE
3.1.2.8- B ... SX GB/IRL (GREAT BRITAIN / IRELAND)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H GB/IE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P GB/IE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28.0 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G31 G20

B48-2SX 34.0 mbar 16.7 mbar

A 37.0 mbar 16.7 mbar

G31 G20 B
Prim. orif. : 370 Prim. orif. : -
Orif. : 2 x 135 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 135 Orif. : 195
3- SBM CATALOGUE
3.1.2.9- B ... SX IT (ITALY)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H IT


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P IT


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28.0 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G30/31 (LPG) Category : I3B/P IT


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.40 3.80 4.10 5.10 5.90 8.20 8.20 10.20 10.20 11.80 11.80 17.70 23.60
Inlet pressure
p (mbar) 30
(4) Injection pressure
(mbar) 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 (See B) 30.0
(6) Mass flow rate
M (kg/h) 0.19 0.300 0.320 0.400 0.460 0.640 0.640 0.800 0.800 0.920 0.920 1.380 1.845
Ø orifices (1/100 mm)
Primary orifice (restrictor) - - - - - - - - - - - (See A) -
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.20 3.50 3.80 4.70 5.40 7.60 7.60 9.40 9.40 10.90 10.90 16.30 21.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 177 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

... / ...
3- SBM CATALOGUE
... / ...

Prim. orif. : - Prim. orif. : 320


G20
Orif. : 2 x 195 Orif. : 195
Prim. orif. : 370 Prim. orif. : -
A G31
Orif. : 2 x 135 Orif. : 135
Prim. orif. : - Prim. orif. : -
G30/G31
Orif. : 2 x 130 Orif. : 130

B48-2SX

G20 16.7 mbar 16.7 mbar

B G31 34.0 mbar 37.0 mbar

G30/G31 30.0 mbar 30.0 mbar


3- SBM CATALOGUE
3.1.2.10- B ... SX NO (NORWAY)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 13AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H NO


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Mass flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G30/G31 (propane) Category : I3B/P NO


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.40 3.80 4.10 5.10 5.90 8.20 8.20 10.20 10.20 11.80 11.80 17.70 23.60
Inlet pressure
p (mbar) 30
(4) Injection pressure
(mbar) 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 (See B) 30.0
(6) Mass flow rate
M (kg/h) 0.190 0.300 0.320 0.400 0.460 0.640 0.640 0.800 0.800 0.920 0.920 1.380 1.845
Ø orifices (1/100 mm)
Primary orifice (restrictor) - - - - - - - - - - - (See A) -
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.20 3.50 3.80 4.70 5.40 7.60 7.60 9.40 9.40 10.90 10.90 16.30 21.80
Required air renewal
3
(m /h) 24 38 41 51 59 82 82 102 102 118 118 177 236

Gas : G30/G31 (propane) Category : I3B/P NO


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.80 4.05 4.35 6.00 7.45 8.35 8.35 12.00 12.00 14.50 14.50 21.95 29.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 35.0 25.0 36.0 36.0 25.0 25.0 36.0 36.0 36.0 36.0 (See B) 36.0
(6) Mass flow rate
M (kg/h) 0.230 0.330 0.355 0.490 0.610 0.685 0.685 0.980 0.980 1.200 1.200 1.810 2.400
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 - - 195 2 x 130 - - - - (See A) -
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.70 3.90 4.20 5.80 7.20 8.10 8.10 11.60 11.60 14.20 14.20 21.40 28.40
Required air renewal
3
(m /h) 28 40.5 43.5 60 74.5 83.5 83.5 120 120 145 145 219.5 290

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

... / ...
3- SBM CATALOGUE
... / ...

Prim. orif. : - Prim. orif. : 320


G20
Orif. : 2 x 195 Orif. : 195
Prim. orif. : - Prim. orif. : -
A G30/G31 - 30
Orif. : 2 x 130 Orif. : 130
Prim. orif. : - Prim. orif. : -
G30/G31- 37
Orif. : 2 x 130 Orif. : 130

B48-2SX

G20 16.7 mbar 16.7 mbar

B G30/G31 - 30 30.0 mbar 30.0 mbar

G30/G31 - 37 30.0 mbar 30.0 mbar


3- SBM CATALOGUE
3.1.2.11- B ... SX NL (NETHERLANDS)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G25 (natural gas type L) Category : I2L NL


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 25
(4) Injection pressure
(mbar) 12.0 10.0 10.5 15.5 13.0 10.5 10.5 15.5 15.5 13.0 13.0 (See B) 13.0
(5) Volumetric flow rate
3
V (m /h) 0.310 0.400 0.470 0.630 0.830 0.940 0.940 1.260 1.260 1.660 1.660 2.490 3.320
Ø orifices (1/100 mm)
Primary orifice (restrictor) 160 180 185 220 250 250 2 x 185 340 2 x 220 370 2 x 250 (See A) 2 x 370
Orifice (injector) 150 185 190 200 235 2 x 190 2 x 190 2 x 200 2 x 200 2 x 235 2 x 235 (See A) 4 x 235
3
Combustion air (m /h) 2.60 3.40 4.00 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 27.90
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption

Prim. orif. : 370 Prim. orif. : 250


A G25
Orif. : 2 x 235 Orif. : 235

B48-2SX

B G25 13.0 mbar 13.0 mbar


3- SBM CATALOGUE
3.1.2.12- B ... SX PT (PORTUGAL)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
CE certificate number 1312AP 1312AP 1312AP 1312AP 1312AP
1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H PT


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P PT


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28.0 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G31 G20

B48-2SX 34.0 mbar 16.7 mbar

A 37.0 mbar 16.7 mbar

G31 G20 B
Prim. orif. : 370 Prim. orif. : -
Orif. : 2 x 135 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 135 Orif. : 195
3- SBM CATALOGUE
3.1.2.13- B ... SX SE (SWEDEN)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232
233 232 233 232 233 249
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection R1/2" (ISO 7/1)

Gas : G20 (natural gas type H) Category : I2H SE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal see local regulations

Gas : G30/G31 (propane) Category : I3B/P SE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.80 4.05 4.35 6.00 7.45 8.35 8.35 12.00 12.00 14.50 14.50 21.95 29.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 35.0 25.0 36.0 36.0 25.0 25.0 36.0 36.0 36.0 36.0 (See B) 36.0
(6) Mass flow rate
M (kg/h) 0.230 0.330 0.355 0.490 0.610 0.685 0.685 0.980 0.980 1.200 1.200 1.810 2.400
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 - - 195 2 x 130 - - - - (See A) -
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.70 3.90 4.20 5.80 7.20 8.10 8.10 11.60 11.60 14.20 14.20 21.40 28.40
Required air renewal see local regulations

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G30/G31 G20

B48-2SX 36.0 mbar 16.7 mbar

A 36.0 mbar 16.7 mbar

G30/G31 G20 B
Prim. orif. : - Prim. orif. : -
Orif. : 2 x 130 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 130 Orif. : 195
3- SBM CATALOGUE
3.1.2.14- B ... SX AU (AUSTRALIA / NEW ZEALAND)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
Gas inlet connection R1/2" (ISO 7/1)

Gas : NG (natural gas)

(1) Nominal heat input


ΣQn (MJ/h) 9.00 12.60 14.00 18.90 25.20 28.00 28.00 37.80 37.80 50.40 50.40 75.60 100.80
Inlet pressure
p (kPa) 1.50
(4) Injection pressure
(kPa) 1.50 1.10 1.20 1.50 1.50 1.20 1.20 1.50 1.50 1.50 1.50 (See B) 1.50
Ø orifices (mm)
Primary orifice (restrictor) - 2.10 2.60 - - 3.60 2 x 2.60 - - - - (See A) -
Orifice (injector) 1.35 1.65 1.70 1.80 2.10 2 x 1.70 2 x 1.70 2 x 1.80 2 x 1.80 2 x 2.10 2 x 2.10 (See A) 4 x 2.10

Gas : LPG (propane)


(1) Nominal heat input
ΣQn (MJ/h) 9.00 12.60 14.00 18.90 25.20 28.00 28.00 37.80 37.80 50.40 50.40 75.60 100.80
Inlet pressure
p (kPa) 2.75
(4) Injection pressure
(kPa) 2.75 2.75 2.45 2.75 2.75 2.45 2.45 2.75 2.75 2.75 2.75 (See B) 2.75
Ø orifices (mm)
Primary orifice (restrictor) - - 2.10 - - 2.60 2 x 2.10 - - - - (See A) -
Orifice (injector) 0.82 1.05 1.10 1.25 1.40 2 x 1.10 2 x 1.10 2 x 1.25 2 x 1.25 2 x 1.40 2 x 1.40 (See A) 4 x 1.40

(1) Nominal heat input ΣQn = Nominal capacity


(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)

Prim. orif. : - Prim. orif. : -


NG
Orif. : 2 x 2.10 Orif. : 2.10
A
Prim. orif. : - Prim. orif. : -
LPG
Orif. : 2 x 1.40 Orif. : 1.40

B48-2SX

NG 1.50 kPa 1.50 kPa


B
LPG 2.75 kPa 2.75 kPa
3- SBM CATALOGUE
3.1.2.15- B ... SX BG (BULGARIA)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
CE certificate number 1312AP 1312AP 1312AP 1312AP 1312AP
1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H BG


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P BG


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28.0 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : AIR BUTANE (Hi=10,5kWh/m3)


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 3.80 6.75 7.60 13.50 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 5.0 7.0 5.0 7.0 7.0
(6) Mass flow rate
M (kg/h) 0.645 1.145 1.290 2.290 4.580
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 210 220 320 2 x 320
Orifice (injector) 240 300 2 x 240 2 x 300 4 x 300
3
Combustion air (m /h) 4.83 8.57 9.66 17.15 34.30
Required air renewal
3
(m /h) 38 67.5 76 135 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

... / ...
3- SBM CATALOGUE
... / ...

Prim. orif. : - Prim. orif. : 320


G20
Orif. : 2 x 195 Orif. : 195
A
Prim. orif. : 370 Prim. orif. : -
G31
Orif. : 2 x 135 Orif. : 135

B48-2SX

G20 16.7 mbar 16.7 mbar


B
G31 34.0 mbar 37.0 mbar
3- SBM CATALOGUE
3.1.2.16- B ... SX HR (CROATIA)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G30/G31 (butane) Category : I3B


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.40 3.80 4.10 5.10 5.90 8.20 8.20 10.20 10.20 11.80 11.80 17.70 23.60
Inlet pressure
p (mbar) 30
(4) Injection pressure
(mbar) 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 (See B) 30.0
(6) Mass flow rate
M (kg/h) 0.190 0.300 0.320 0.400 0.460 0.640 0.640 0.800 0.800 0.920 0.920 1.380 1.845
Ø orifices (1/100 mm)
Primary orifice (restrictor) - - - - - - - - - - - (See A) -
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.20 3.50 3.80 4.70 5.40 7.60 7.60 9.40 9.40 10.90 10.90 16.30 21.80
Required air renewal
3
(m /h) 25 38 41 51 67.5 82 82 102 102 135 135 177 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G30/G31 G20

B48-2SX 30.0 mbar 16.7 mbar

A 30.0 mbar 16.7 mbar

G30/G31 G20 B
Prim. orif. : - Prim. orif. : -
Orif. : 2 x 130 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 130 Orif. : 195
3- SBM CATALOGUE
3.1.2.17- B ... SX HU (HUNGARY)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
Nox class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H HU


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 25
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 140 160 180 210 250 240 2 x 180 300 2 x 210 360 2 x 250 (See A) 2 x 360
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 38 41 51 67.5 82 82 102 102 135 135 202.5 270

Gas : G25.1 (natural gas type L) Category : I2S HU


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 25
(4) Injection pressure
(mbar) 12.0 10.0 10.5 15.5 13.0 10.5 10.5 15.5 15.5 13.0 13.0 (See B) 13.0
(5) Volumetric flow rate
3
V (m /h) 0.310 0.400 0.470 0.630 0.830 0.940 0.940 1.260 1.260 1.660 1.660 2.490 3.320
Ø orifices (1/100 mm)
Primary orifice (restrictor) 160 180 185 220 250 250 2 x 185 340 2 x 220 370 2 x 250 (See A) 2 x 370
Orifice (injector) 150 185 190 200 235 2 x 190 2 x 190 2 x 200 2 x 200 2 x 235 2 x 235 (See A) 4 x 235
3
Combustion air (m /h) 2.60 3.40 4.00 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 27.90
Required air renewal
3
(m /h) 25 38 41 51 67.5 82 82 102 102 135 135 202.5 270

Gas : G30/G31 (propane) Category : I3B/P HU


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.40 3.80 4.10 5.10 5.90 8.20 8.20 10.20 10.20 11.80 11.80 17.70 23.60
Inlet pressure
p (mbar) 30
(4) Injection pressure
(mbar) 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 (See B) 30.0
(6) Mass flow rate
M (kg/h) 0.190 0.300 0.320 0.400 0.460 0.640 0.640 0.800 0.800 0.920 0.920 1.380 1.845
Ø orifices (1/100 mm)
Primary orifice (restrictor) - - - - - - - - - - - (See A) -
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.20 3.50 3.80 4.70 5.40 7.60 7.60 9.40 9.40 10.90 10.90 16.30 21.80
Required air renewal
3
(m /h) 25 38 41 51 67.5 82 82 102 102 135 135 177 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

... / ...
3- SBM CATALOGUE
... / ...

Prim. orif. : 360 Prim. orif. : 250


G20
Orif. : 2 x 195 Orif. : 195
Prim. orif. : 370 Prim. orif. : 250
A G25.1
Orif. : 2 x 235 Orif. : 235
Prim. orif. : - Prim. orif. : -
G30/G31
Orif. : 2 x 130 Orif. : 130

B48-2SX

G20 16.7 mbar 16.7 mbar

B G25.1 13.0 mbar 13.0 mbar

G30/G31 30.0 mbar 30.0 mbar


3- SBM CATALOGUE
3.1.2.18- B ... SX IE (INTERNATIONAL)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
Gas inlet connection G1/2" (ISO 228/1) or R1/2" (ISO 7/1)

Gas : G20 (natural gas type H) Category : I2Esi


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure 37
p (mbar)
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28.0 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 30
(4) Injection pressure
(mbar) 30.0 21.0 21.0 28.0 30.0 21.0 21.0 28.0 28.0 28.0 30.0 (See B) 28.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) - 130 145 220 - 210 2 x 145 260 2 x 220 - - (See A) -
Orifice (injector) 82 105 110 125 137 2 x 110 2 x 110 2 x 125 2 x 125 2 x 137 2 x 137 (See A) 4 x 137
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

... / ...
3- SBM CATALOGUE
... / ...

Prim. orif. : - Prim. orif. : 320


G20
Orif. : 2 x 195 Orif. : 195
Prim. orif. : 370 Prim. orif. : -
A G31 - 37
Orif. : 2 x 135 Orif. : 135
Prim. orif. : - Prim. orif. : -
G31 - 30
Orif. : 2 x 137 Orif. : 137

B48-2SX

G20 16.7 mbar 16.7 mbar

B G31 - 37 34.0 mbar 37.0 mbar

G31 - 30 28.0 mbar 30.0 mbar


3- SBM CATALOGUE
3.1.2.19- B ... SX JA (JAPAN)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
Gas inlet connection R1/2" (ISO 7/1)

Gas : 13A (natural gas type H)


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 15
(4) Injection pressure
(mbar) 15.0 11.0 12.0 15.0 15.0 12.0 12.0 15.0 15.0 13.5 15.0 (See B) 13.5
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) - 210 260 - - 360 2 x 260 - - - - (See A) -
Orifice (injector) 135 165 170 180 210 2 x 170 2 x 170 2 x 180 2 x 180 2 x 210 2 x 210 (See A) 4 x 210
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption

Prim. orif. : - Prim. orif. : -


A 13A
Orif. : 2 x 210 Orif. : 210

B48-2SX

B 13A 13.5 mbar 15.0 mbar


3- SBM CATALOGUE
3.1.2.20- B ... SX PL (POLAND)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
Nox class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2E PL


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : GZ350 (natural gas) Category : I2Lw PL


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 12.50 13.50 19.25 25.00
Inlet pressure
p (mbar) 13
(4) Injection pressure
(mbar) 11.0 5.0 4.5 6.5 8.5 4.5 4.5 6.5 6.5 7.5 8.5 (See B) 7.5
(5) Volumetric flow rate
3
V (m /h) 0.380 0.500 0.570 0.770 1.010 1.140 1.140 1.540 1.540 1.870 2.020 2.880 3.740
Ø orifices (1/100 mm)
Primary orifice (restrictor) 250 210 220 290 360 360 2 x 220 450 2 x 290 - 2 x 360 (See A) -
Orifice (injector) 170 240 260 280 300 2 x 260 2 x 260 2 x 280 2 x 280 2 x 300 2 x 300 (See A) 4 x 300
3
Combustion air (m /h) 2.45 3.25 3.70 5.00 6.50 7.40 7.40 10.00 10.00 12.10 13.00 18.60 24.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 192.5 270

Gas : G30/31 (Propane - Butane) Category : I3B/P PL


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 36
(4) Injection pressure
(mbar) 34.0 30.0 25.0 30.0 36.0 25.0 25.0 29.0 30.0 36.0 36.0 (See B) 36.0
(6) Mass flow rate
M (kg/h) 0.204 0.270 0.311 0.417 0.553 0.622 0.622 0.835 0.835 1.105 1.105 1.658 2.210
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 - - (See A) -
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.60 3.60 4.00 5.40 6.50 7.90 7.90 10.80 10.80 13.00 13.00 19.50 26.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

... / ...
3- SBM CATALOGUE
... / ...

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2

Gas : GZ410 Category : I2Lw PL


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 12.0 10.0 10.5 15.5 14.0 10.5 10.5 15.5 15.5 14.5 14.0 (See B) 14.5
(5) Volumetric flow rate
3
V (m /h) 0.345 0.455 0.520 0.700 0.925 1.045 1.045 1.400 1.400 1.850 1.850 2.775 3.710
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 185 195 280 - 280 2 x 195 500 2 x 280 - - (See A) -
Orifice (injector) 150 185 190 200 235 2 x 190 2 x 190 2 x 200 2 x 200 2 x 235 2 x 235 (See A) 4 x 235
3
Combustion air (m /h) 2.45 3.25 3.70 5.00 6.60 7.45 7.45 10.00 10.00 13.20 13.20 19.80 26.45
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption

Prim. orif. : - Prim. orif. : 320


G20
Orif. : 2 x 195 Orif. : 195
Prim. orif. : - Prim. orif. : 360
GZ350
Orif. : 2 x 300 Orif. : 300
A Prim. orif. : - Prim. orif. : -
G30/31
Orif. : 2 x 130 Orif. : 130
Prim. orif. : - Prim. orif. : -
GZ350
Orif. : 2 x 235 Orif. : 235

B48-2SX

G20 16.7 mbar 16.7 mbar

GZ350 7.5 mbar 8.5 mbar


B
G30/31 36.0 mbar 36.0 mbar

GZ350 14.5 mbar 14.0 mbar


3- SBM CATALOGUE
3.1.2.21- B ... SX CZ (CZECH REPUBLIC)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
Nox class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H CZ


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
(3) ΣQn (Hs) (kW) 2.80 3.65 4.25 5.65 7.50 8.45 8.45 11.35 11.35 15.00 15.00 22.50 30.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G30/G31 (propane) Category : I3B/P CZ


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.80 3.80 4.25 5.80 7.00 8.50 8.50 11.60 11.60 14.00 14.00 21.00 28.00
(3) ΣQn (Hs) (kW) 3.05 4.10 4.60 6.25 7.55 9.20 9.20 12.55 12.55 15.15 15.15 22.70 30.30
Inlet pressure
p (mbar) 50
(4) Injection pressure
(mbar) 37.0 30.0 34.0 36.0 44.0 34.0 34.0 36.0 36.0 44.0 44.0 (See B) 44.0
(6) Mass flow rate
M (kg/h) 0.220 0.300 0.335 0.455 0.550 0.665 0.665 0.910 0.910 1.100 1.100 1.650 2.200
Ø orifices (1/100 mm)
Primary orifice (restrictor) 100 110 130 155 210 180 2 x 130 210 2 x 155 280 2 x 210 (See A) 2 x 280
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.60 3.60 4.00 5.40 6.50 7.90 7.90 10.80 10.80 13.00 13.00 19.50 26.00
Required air renewal
3
(m /h) 28 38 42.5 58 70 85 85 116 116 140 140 210 280

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(3) Hs = Gross calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G30/G31 G20

B48-2SX 44.0 mbar 16.7 mbar

A 44.0 mbar 16.7 mbar

G30/G31 G20
B
Prim. orif. : 280 Prim. orif. : -
Orif. : 2 x 130 Orif. : 2 x 195
Prim. orif. : 210 Prim. orif. : 320
Orif. : 130 Orif. : 195
3- SBM CATALOGUE
3.1.2.22- B ... SX RO (ROMANIA)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
Nox class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H RO


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 195 200 210 300 - 300 2 x 210 500 2 x 300 - - (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P RO


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28.0 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G31 G20

B48-2SX 34.0 mbar 16.7 mbar

A 37.0 mbar 16.7 mbar

G31 G20
B
Prim. orif. : 370 Prim. orif. : -
Orif. : 2 x 135 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 135 Orif. : 195
3- SBM CATALOGUE
3.1.2.23- B ... SX SK (SLOVAKIA)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
Nox class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)
Electrical protection IP 43

Gas : G20 (natural gas type H) Category : I2H SK


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
(3) ΣQn (Hs) (kW) 2.80 3.65 4.25 5.65 7.50 8.45 8.45 11.35 11.35 15.00 15.00 22.50 30.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G30/G31 (propane) Category : I3B/P SK


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.80 3.80 4.25 5.80 7.00 8.50 8.50 11.60 11.60 14.00 14.00 21.00 28.00
(3) ΣQn (Hs) (kW) 3.05 4.10 4.60 6.25 7.55 9.20 9.20 12.55 12.55 15.15 15.15 22.70 30.30
Inlet pressure
p (mbar) 50
(4) Injection pressure
(mbar) 37.0 30.0 34.0 36.0 44.0 34.0 34.0 36.0 36.0 44.0 44.0 (See B) 44.0
(6) Mass flow rate
M (kg/h) 0.220 0.300 0.335 0.455 0.550 0.665 0.665 0.910 0.910 1.100 1.100 1.650 2.200
Ø orifices (1/100 mm)
Primary orifice (restrictor) 100 110 130 155 210 180 2 x 130 210 2 x 155 280 2 x 210 (See A) 2 x 280
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.60 3.60 4.00 5.40 6.50 7.90 7.90 10.80 10.80 13.00 13.00 19.50 26.00
Required air renewal
3
(m /h) 28 38 42.5 58 70 85 85 116 116 140 140 210 280

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(3) Hs = Gross calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

Heaters supplied with pre-wired plug(s) 3m/10ft.

G30/G31 G20

B48-2SX 44.0 mbar 16.7 mbar

A 44.0 mbar 16.7 mbar

G30/G31 G20
B
Prim. orif. : 280 Prim. orif. : -
Orif. : 2 x 130 Orif. : 2 x 195
Prim. orif. : 210 Prim. orif. : 320
Orif. : 130 Orif. : 195
3- SBM CATALOGUE
3.1.2.24- B ... SX SI (SLOVENIA)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP 1312AP249
CE certificate number 1312AP230 1312AP231 1312AP232
233 232 233 232 233
Nox class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2Esi SI


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P SI


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28.0 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G31 G20

B48-2SX 34.0 mbar 16.7 mbar

A 37.0 mbar 16.7 mbar

G31 G20
B
Prim. orif. : 370 Prim. orif. : -
Orif. : 2 x 135 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 135 Orif. : 195
3- SBM CATALOGUE
3.1.2.25- B ... SX CH (SWITZERLAND)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : II2H3P


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : II2H3P


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28.0 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G31 G20

B48-2SX 34.0 mbar 16.7 mbar

A 37.0 mbar 16.7 mbar

G31 G20
B
Prim. orif. : 370 Prim. orif. : -
Orif. : 2 x 135 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 135 Orif. : 195
3- SBM CATALOGUE
3.1.2.26- B ... SX TR (TURKEY)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
Nox class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H TR


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G20 (natural gas type H) Category : I2H TR


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 200
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 70 80 85 97 110 120 2 x 85 137 2 x 97 159 2 x 110 (See A) 2 x 159
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P TR


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28.0 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

... / ...
3- SBM CATALOGUE
... / ...

Prim. orif. : - Prim. orif. : 320


G20 - 20
Orif. : 2 x 195 Orif. : 195
Prim. orif. : 159 Prim. orif. : 110
A G20 - 200
Orif. : 2 x 135 Orif. : 195
Prim. orif. : 370 Prim. orif. : -
G31
Orif. : 2 x 135 Orif. : 135

B48-2SX

G20 - 20 16.7 mbar 16.7 mbar

B G20 - 200 16.7 mbar 16.7 mbar

G31 34.0 mbar 37.0 mbar


3- SBM CATALOGUE
3.1.2.27 B ... SX RU (RUSSIA)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B32+ B64-2
B16
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 195 200 210 300 - 300 2 x 210 500 300 - - (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 30
(4) Injection pressure
(mbar) 30.0 21.0 21.0 28.0 30.0 21.0 21.0 28.0 28.0 28.0 30.0 (See B) 28.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) - 130 145 220 - 210 2 x 145 260 2 x 220 - - (See A) -
Orifice (injector) 82 105 110 125 137 2 x 110 2 x 110 2 x 125 2 x 125 2 x 137 2 x 137 (See A) 4 x 137
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G31 G20

B32+B16SX 28.0 mbar 16.7 mbar

A 30.0 mbar 16.7 mbar

G31 G20
B
Prim. orif. : - Prim. orif. : -
Orif. : 2 x 137 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : -
Orif. : 137 Orif. : 195
3- SBM CATALOGUE
3.1.2.28 B ... SX UA (UKRAINE)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B32+ B64-2
B16
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 17
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 195 200 210 300 - 300 2 x 210 500 300 - - (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 30
(4) Injection pressure
(mbar) 30.0 21.0 21.0 28.0 30.0 21.0 21.0 28.0 28.0 28.0 30.0 (See B) 28.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) - 130 145 220 - 210 2 x 145 260 2 x 220 - - (See A) -
Orifice (injector) 82 105 110 125 137 2 x 110 2 x 110 2 x 125 2 x 125 2 x 137 2 x 137 (See A) 4 x 137
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G31 G20

B32+B16SX 28.0 mbar 16.7 mbar

A 30.0 mbar 16.7 mbar

G31 G20
B
Prim. orif. : - Prim. orif. : -
Orif. : 2 x 137 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : -
Orif. : 137 Orif. : 195
3- SBM CATALOGUE
3.1.2.29- B ... SX EE (ESTONIA)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
Nox class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H EE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 21.00 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G30/G31 (propane/butane) Category : I3B/P EE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.40 3.80 4.10 5.10 5.90 8.20 8.20 10.20 10.20 11.80 11.80 17.70 23.60
Inlet pressure
p (mbar) 30
(4) Injection pressure
(mbar) 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 (See B) 30.0
(6) Mass flow rate
M (kg/h) 0.190 0.300 0.320 0.400 0.460 0.640 0.640 0.800 0.800 0.920 0.920 1.380 1.845
Ø orifices (1/100 mm)
Primary orifice (restrictor) - - - - - - - - - - - (See A) -
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 (See A) 4 x 130
3
Combustion air (m /h) 2.20 3.50 3.80 4.70 5.40 7.60 7.60 9.40 9.40 10.90 10.90 16.30 21.80
Required air renewal
3
(m /h) 24 38 41 51 59 82 82 102 102 118 118 177 236

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G30/G31 G20

B48-2SX 30.0 mbar 16.7 mbar

A 30.0 mbar 16.7 mbar

G30/G31 G20
B
Prim. orif. : - Prim. orif. : -
Orif. : 2 x 130 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 130 Orif. : 195
3- SBM CATALOGUE
3.1.2.30- B ... SX LT (LITHUANIA)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B48-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number 1312AP230 1312AP231 1312AP232 1312AP249
233 232 233 232 233
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H LT


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 (See B) 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.145 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 (See A) -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 (See A) 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 21.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

Gas : G31 (propane) Category : I3P LT


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 20.25 27.00
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0 21.0 21.0 27.5 28 34.0 37.0 (See B) 34.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 1.590 2.110
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 - 185 2 x 130 240 2 x 180 370 - (See A) 2 x 370
Orifice (injector) 82 105 110 125 135 2 x 115 2 x 110 2 x 125 2 x 125 2 x 135 2 x 135 (See A) 4 x 135
3
Combustion air (m /h) 2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 18.90 25.20
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 202.5 270

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption

G31 G20

B48-2SX 34.0 mbar 16.7 mbar

A 37.0 mbar 16.7 mbar

G31 G20 B
Prim. orif. : 370 Prim. orif. : -
Orif. : 2 x 135 Orif. : 2 x 195
Prim. orif. : - Prim. orif. : 320
Orif. : 135 Orif. : 195
3- SBM CATALOGUE
3.1.3- GENERAL SPECIFICATIONS OF "KOMFORT" AUTOMATIC HEATERS

B 6 KOMFORT ............................ 3.1.3.1

B 8 KOMFORT ............................ 3.1.3.2

B 10 KOMFORT .......................... 3.1.3.3

B 12 KOMFORT .......................... 3.1.3.4

B 16 KOMFORT .......................... 3.1.3.5

B 20 KOMFORT .......................... 3.1.3.6

B 20-2 KOMFORT ....................... 3.1.3.7


3- SBM CATALOGUE

B 24 KOMFORT .......................... 3.1.3.8

B 24-2 KOMFORT ....................... 3.1.3.9

B 32 KOMFORT ........................ 3.1.3.10

B 32-2 KOMFORT ..................... 3.1.3.11

B 64-2 KOMFORT .....................3.1.3.12


3- SBM CATALOGUE
Related sections :

Control modules .........................................................................3.2


Accessories ................................................................................3.3
Installation......................................................................................4
Operation........................................................................................5
Maintenance ...................................................................................6
Trouble-shooting ...........................................................................7
Spare parts.....................................................................................8
Applications ...................................................................................9
3- SBM CATALOGUE
3.1.3.1- B 6 KOMFORT

CONTENTS OF INDIVIDUAL BOX

Weight : 2.50 kg 186

147 172

202 222
318
Dimensions in mm.

Power supply
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory
Comsumption : 0.1A
Individual fuse : 1 fuse 0.25A (RP32) not included
Ignition cycle length : 45 seconds
2
Connection : 1 prewired plug, length 1m - 3 x 0,75mm included
Fixing
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.
26 26

or

Fixing : see (4.5)

Gas connection
Gas inlet connection : G1/2" cylindrical male
Other
ISO 228/1 - G 1/2 specifications for
different countries
(see 3.1.4)
Germany
3- SBM CATALOGUE
3.1.3.2- B 8 KOMFORT

CONTENTS OF INDIVIDUAL BOX

Weight : 2.90 kg 218

147 172

202 285
382
Dimensions in mm.

Power supply
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory
Comsumption : 0.1A
Individual fuse : 1 fuse 0.25A (RP32) not included
Ignition cycle length : 45 seconds
2
Connection : 1 prewired plug, length 1m - 3 x 0,75mm included
Fixing
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.
26 26

or

Fixing : see (4.5)

Gas connection
Gas inlet connection : G1/2" cylindrical male
Other
ISO 228/1 - G 1/2 specifications for
different countries
(see 3.1.4)
Germany
3- SBM CATALOGUE
3.1.3.3- B 10 KOMFORT

CONTENTS OF INDIVIDUAL BOX

Weight : 3.10 kg 243

147 172

202 334
431
Dimensions in mm.

Power supply
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory
Comsumption : 0.25A
Individual fuse : 1 fuse 0.1A (RP32) not included
Ignition cycle length : 45 seconds
2
Connection : 1 prewired plug, length 1m - 3 x 0,75mm included
Fixing
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.
26 26

or

Fixing : see (4.5)

Gas connection
Gas inlet connection : G1/2" cylindrical male
Other
ISO 228/1 - G 1/2 specifications for
different countries
(see 3.1.4)
Germany
3- SBM CATALOGUE
3.1.3.4- B 12 KOMFORT

CONTENTS OF INDIVIDUAL BOX

Weight : 3.40 kg 281

147 172

202 411
508
Dimensions in mm.

Power supply
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory
Comsumption : 0.1A
Individual fuse : 1 fuse 0.25A (RP32) not included
Ignition cycle length : 45 seconds
2
Connection : 1 prewired plug, length 1m - 3 x 0,75mm included
Fixing
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.
26 26

or

Fixing : see (4.5)

Gas connection
Gas inlet connection : G1/2" cylindrical male
Other
ISO 228/1 - G 1/2 specifications for
different countries
(see 3.1.4)
Germany
3- SBM CATALOGUE
3.1.3.5- B 16 KOMFORT
CONTENTS OF INDIVIDUAL BOX

299
Weight : 5.20 kg

222 247

276 536
620
Dimensions in mm. 674

Power supply
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory
Comsumption : 0.1A
Individual fuse : 1 fuse 0.25A (RP32) not included
Ignition cycle length : 45 seconds
2
Connection : 1 prewired plug, length 1m - 3 x 0,75mm included
Fixing
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.

26 26

or

Fixing : see (4.5)

Gas connection
Gas inlet connection : G1/2" cylindrical male
Other
ISO 228/1 - G 1/2 specifications for
different countries
(see 3.1.4)
Germany
3- SBM CATALOGUE
3.1.3.6- B 20 KOMFORT
CONTENTS OF INDIVIDUAL BOX

243
Weight : 6.20 kg

222 247

406 334
419
Dimensions in mm.
473
Power supply
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory
Comsumption : 0.1A
Individual fuse : 1 fuse 0.25A (RP32) not included
Ignition cycle length : 45 seconds
2
Connection : 1 prewired plug, length 1m - 3 x 0,75mm included
Fixing
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.
26

26

or

Fixing : see (4.5)

Gas connection
Gas inlet connection : G1/2" cylindrical male
Other
ISO 228/1 - G 1/2 specifications for
different countries
(see 3.1.4)
Germany
3- SBM CATALOGUE
3.1.3.7- B 20-2 KOMFORT
CONTENTS OF INDIVIDUAL BOX

2X

243
Weight : 6.20 kg

222 247

406 334
419
Dimensions in mm.
473
Power supply
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory
Comsumption : 0.1A
Individual fuse : 2 fuses 0.25A (RP32) not included
Ignition cycle length : 45 seconds
2
Connection : 2 prewired plugs, length 1m - 3 x 0,75mm included
Fixing
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.
26

26

or

Fixing : see (4.5)

Gas connection
2 gas inlet connections : G1/2" cylindrical male
Other
ISO 228/1 - G 1/2 specifications for
different countries
(see 3.1.4)
Germany
3- SBM CATALOGUE
3.1.3.8- B 24 KOMFORT
CONTENTS OF INDIVIDUAL BOX

281
Weight : 6.80 kg

222 247

406 411
496
Dimensions in mm. 550
Power supply
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory
Comsumption : 0.1A
Individual fuse : 1 fuse 0.25A (RP32) not included
Ignition cycle length : 45 seconds
2
Connection : 1 prewired plug, length 1m - 3 x 0,75mm included
Fixing
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.
26

26

or

Fixing : see (4.5)

Gas connection
Gas inlet connection : G1/2" cylindrical male

Other
ISO 228/1 - G 1/2
specifications for
different countries
(see 3.1.4)
Germany
3- SBM CATALOGUE
3.1.3.9- B 24-2 KOMFORT
CONTENTS OF INDIVIDUAL BOX

2X

281
Weight : 6.80 kg

222 247

406 411
496
Dimensions in mm. 550
Power supply
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory
Comsumption : 2 x 0.1A
Individual fuse : 2 fuses 0.25A (RP32) not included
Ignition cycle length : 45 seconds
2
Connection : 2 prewired plugs, length 1m - 3 x 0,75mm included
Fixing
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.
26

26

or

Fixing : see (4.5)

Gas connection
2 gas inlet connections : G1/2" cylindrical male

Other
ISO 228/1 - G 1/2
specifications for
different countries
(see 3.1.4)
Germany
3- SBM CATALOGUE
3.1.3.10- B 32 KOMFORT
CONTENTS OF INDIVIDUAL BOX

Weight : 8.00 kg 299

222 247

406 536
620
Dimensions in mm. 674
Power supply
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory
Comsumption : 0.1A
Individual fuse : 1 fuse 0.25A (RP32) not included
Ignition cycle length : 45 seconds
2
Connection : 1 prewired plug, length 1m - 3 x 0,75mm included
Fixing
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.
26

26

or

Fixing : see (4.5)

Gas connection
Gas inlet connection : G1/2" cylindrical male

Autres
Other
ISO 228/1 - G 1/2 specifications
caractéristiques
for
different
seloncountries
pays
(see 3.1.4)
Germany
3- SBM CATALOGUE
3.1.3.11- B 32-2 KOMFORT
CONTENTS OF INDIVIDUAL BOX

2X

299
Weight : 8.00 kg

222 247

406 536
620
Dimensions in mm. 674
Power supply
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory
Comsumption : 2 x 0.1A
Individual fuse : 2 fuses 0.25A (RP32) not included
Ignition cycle length : 45 seconds
2
Connection : 2 prewired plugs, length 1m - 3 x 0,75mm included
Fixing
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm.
26

26

or

Fixing : see (4.5)

Gas connection
2 gas inlet connections : G1/2" cylindrical male

Other
ISO 228/1 - G 1/2
specifications for
different countries
(see 3.1.4)
Germany
3- SBM CATALOGUE
3.1.3.12- B 64-2 KOMFORT

CONTENTS OF INDIVIDUAL BOX

1m 3m

299 633 299


Weight : 14.00 kg

247
222

406 1065
1166
Dimensions in mm. 1269

Power supply
Power supply : 230V (+10% , -15%) / 50Hz - 60Hz . Neutral mandatory
Comsumption : 2 x 0.1A
Individual fuse : 2 fuses 0.25A (RP32) not included
Ignition cycle length : 45 seconds
2
Connection : 2 prewired plugs 1m and 3m - 3 x 0,75mm included
Fixing
2 directional brackets for fixing on steel tube 3/4" or square profile 25 x 25 mm.

Fixing : see (4.5) 26 26

or

Gas connection
2 gas inlet connections : G1/2" cylindrical male
Other
ISO 228/1 - G 1/2 specifications for
different countries
(see 3.1.4)
Germany
3- SBM CATALOGUE
3.1.4- SPECIFICATIONS OF "KOMFORT" AUTOMATIC HEATERS

Countries of distribution with CE marking


GERMANY B ... KOMFORT............. 3.1.4.1
3- SBM CATALOGUE
3.1.4.1- B ... KOMFORT (GERMANY)

B6 B8 B10 B12 B16 B20 B20-2 B24 B24-2 B32 B32-2 B64-2
1312AP 1312AP 1312AP 1312AP 1312AP 1312AP 1312AP 1312AP 1312AP
CE certificate number
230 231 232 233 232 233 232 233 249
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)

Gas : G20 (natural gas type H) Catégorie : I2ELL DE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 27.00
(3) ΣQn (Hs) (kW) 2.80 3.65 4.25 5.65 7.50 8.45 8.45 11.35 11.35 15.00 15.00 30.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7 12.0 12.0 15.0 15.0 16.7 16.7 16.7
(5) Volumetric flow rate
3
V (m /h) 0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.860
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320 260 2 x 195 380 2 x 240 - 2 x 320 -
Orifice (injector) 135 165 170 180 195 2 x 170 2 x 170 2 x 180 2 x 180 2 x 195 2 x 195 4 x 195
3
Combustion air (m /h) 2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 27.80
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 270

Gas : G25 (natural gas type L) Category : I2ELL DE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75 7.60 7.60 10.20 10.20 13.50 13.50 27.00
(3) ΣQn (Hs) (kW) 2.80 3.65 4.25 5.65 7.50 8.45 8.45 11.35 11.35 15.00 15.00 30.00
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 12.0 10.0 10.5 15.5 14.0 10.5 10.5 15.5 15.5 14.5 14.0 14.5
(5) Volumetric flow rate
3
V (m /h) 0.310 0.405 0.470 0.630 0.830 0.935 0.935 1.255 1.255 1.660 1.660 3.325
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 185 195 280 - 280 2 x 195 500 2 x 280 - - -
Orifice (injector) 150 185 190 200 235 2 x 190 2 x 190 2 x 200 2 x 200 2 x 235 2 x 235 4 x 235
3
Combustion air (m /h) 2.60 3.40 3.80 5.30 7.00 7.90 7.90 10.60 10.60 14.00 14.00 28.00
Required air renewal
3
(m /h) 25 33 38 51 67.5 76 76 102 102 135 135 270

Gas : G30/G31 (propane) Category : I3B/P DE


(1) Nominal heat input
(2) ΣQn (Hi) (kW) 2.80 3.80 4.25 5.80 7.00 8.50 8.50 11.60 11.60 14.00 14.00 28.00
(3) ΣQn (Hs) (kW) 3.05 4.10 4.60 6.25 7.55 9.20 9.20 12.55 12.55 15.15 15.15 30.30
Inlet pressure
p (mbar) 50
(4) Injection pressure
(mbar) 37.0 30.0 34.0 36.0 44.0 34.0 34.0 36.0 36.0 44.0 44.0 44.0
(6) Mass flow rate
M (kg/h) 0.220 0.300 0.335 0.455 0.550 0.665 0.665 0.910 0.910 1.100 1.100 2.200
Ø orifices (1/100 mm)
Primary orifice (restrictor) 100 110 130 155 210 180 2 x 130 210 2 x 155 280 2 x 210 2 x 280
Orifice (injector) 78 100 105 120 130 2 x 105 2 x 105 2 x 120 2 x 120 2 x 130 2 x 130 4 x 130
3
Combustion air (m /h) 2.60 3.60 4.00 5.40 6.50 7.90 7.90 10.80 10.80 13.00 13.00 26.00
Required air renewal
3
(m /h) 28 38 42.5 58 70 85 85 116 116 140 140 280

(1) Nominal heat input ΣQn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(3) Hs = Gross calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.1.4)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.5- GENERAL SPECIFICATIONS OF "M" MANUAL HEATERS

B 6 M ........................................... 3.1.5.1

B 8 M ........................................... 3.1.5.2

B 10 M ......................................... 3.1.5.3

B 12 M ......................................... 3.1.5.4

B 16 M ......................................... 3.1.5.5

Related sections :

Control modules .........................................................................3.2


Accessories ................................................................................3.3
Installation......................................................................................4
Operation........................................................................................5
Maintenance ...................................................................................6
Trouble-shooting ...........................................................................7
Spare parts.....................................................................................8
Applications ...................................................................................9
3- SBM CATALOGUE
3.1.5.1- B 6 M

CONTENTS OF INDIVIDUAL BOX

Weight : 2.50 kg 186

147 172

202 222
318
Dimensions in mm.

Fixing Other
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. specifications for
different countries
(see 3.1.6)
26 26 Australia
Austria
Belgium
Denmark
Finland
or France
G. Britain / Ireland
Germany
International
Fixing : see (4.5)
Italy
Netherlands
Gas connection Portugal
Gas inlet connection : G1/2" cylindrical male or R1/2" conical male - voir (3.1.6) Russia
Spain
Sweden
ISO 228/1 - G 1/2 Switzerland
ISO 7/1 - R 1/2
3- SBM CATALOGUE
3.1.5.2- B 8 M

CONTENTS OF INDIVIDUAL BOX

Weight : 2.90 kg 218

147 172

202 285
382
Dimensions in mm.

Fixing Other
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. specifications for
different countries
(see 3.1.6)
26 26 Australia
Austria
Belgium
Denmark
Finland
or France
G. Britain / Ireland
Germany
International
Fixing : see (4.5) Italy
Netherlands
Gas connection Portugal
Russia
Gas inlet connection : G1/2" cylindrical male or R1/2" conical male - see (3.1.6)
Spain
Sweden
ISO 228/1 - G 1/2 Switzerland
ISO 7/1 - R 1/2
3- SBM CATALOGUE
3.1.5.3- B 10 M

CONTENTS OF INDIVIDUAL BOX

Weight : 3.10 kg 243

147 172

202 334
431
Dimensions in mm.

Fixing Other
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. specifications for
different countries
26 26 (see 3.1.6)
Australia
Austria
Belgium
Denmark
or Finland
France
G. Britain / Ireland
Germany
Fixing : see (4.5) International
Italy
Gas connection Netherlands
Portugal
Gas inlet connection : G1/2" cylindrical male or R1/2" conical male - see (3.1.6)
Russia
Spain
ISO 228/1 - G 1/2 Sweden
ISO 7/1 - R 1/2 Switzerland
3- SBM CATALOGUE
3.1.5.4- B 12 M

CONTENTS OF INDIVIDUAL BOX

Weight : 3.40 kg 281

147 172

202 411
508
Dimensions in mm.

Fixing Other
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. specifications for
different countries
26 26 (see 3.1.6)
Australia
Austria
Belgium
Denmark
Finland
or France
G. Britain / Ireland
Germany
Fixing : see (4.5) International
Italy
Netherlands
Gas connection Portugal
Gas inlet connection : G1/2" cylindrical male or R1/2" conical male - see (3.1.6) Russia
Spain
Sweden
ISO 228/1 - G 1/2 ISO 7/1 - R 1/2 Switzerland
3- SBM CATALOGUE
3.1.5.5- B 16 M

CONTENTS OF INDIVIDUAL BOX

Weight : 4.10 kg 299

147 172

202 536
632
Dimensions in mm.

Fixing Other
1 directional bracket for fixing on steel tube 3/4" or square profile 25 x 25 mm. specifications for
different countries
26 26 (see 3.1.6)
Australia
Austria
Belgium
Denmark
Finland
or France
G. Britain / Ireland
Germany
International
Fixing : see (4.5) Italy
Netherlands
Gas connection Portugal
Gas inlet connection : G1/2" cylindrical male or R1/2" conical male - see (3.1.6) Russia
Spain
Sweden
ISO 228/1 - G 1/2 ISO 7/1 - R 1/2 Switzerland
3- SBM CATALOGUE
3.1.6- SPECIFICATIONS OF "M" MANUAL HEATERS

Countries of distribution with CE marking


GERMANY B ... M CE ..................... 3.1.6.1
AUSTRIA B ... M CE ..................... 3.1.6.2
BELGIUM B ... M CE ..................... 3.1.6.3
DENMARK B ... M CE ..................... 3.1.6.4
SPAIN B ... M CE ..................... 3.1.6.5
FINLAND B ... M CE ..................... 3.1.6.6
FRANCE B ... M CE ..................... 3.1.6.7
G.BRITAIN / IRELAND B ... M CE ..................... 3.1.6.8
ITALY B ... M CE ..................... 3.1.6.9
NETHERLANDS B ... M CE ................... 3.1.6.10
PORTUGAL B ... M CE ................... 3.1.6.11
SWEDEN B ... M CE ................... 3.1.6.12

Other countries of distribution


AUSTRALIA / N. ZEALAND B ... M AU................... 3.1.6.13
INTERNATIONAL B ... M IE..................... 3.1.6.14
SWITZERLAND B ... M CH................... 3.1.6.15
RUSSIA B ... M RU................... 3.1.6.16
3- SBM CATALOGUE
3.1.6.1- B ... M CE (GERMANY)

B6 B8 B10 B12 B16


CE certificate number 1312AP230 1312AP231 1312AP232
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2ELL DE


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
(3) Qn (Hs) (kW) 2.80 3.65 4.25 5.65 7.50
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal
3
(m /h) 25 33 38 51 67.5

Gas : G25 (natural gas type L) Category : I2ELL DE


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
(3) Qn (Hs) (kW) 2.80 3.65 4.25 5.65 7.50
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 12.0 10.0 10.5 15.5 14.0
(5) Volumetric flow rate
V (m3/h) 0.310 0.405 0.470 0.630 0.830
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 185 195 280 -
Orifice (injector) 150 185 190 200 235
Combustion air (m3/h) 2.60 3.40 3.80 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

Gas : G30/G31 (propane) Category : I3B/P DE


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.80 3.80 4.25 5.80 7.00
(3) Qn (Hs) (kW) 3.05 4.10 4.60 6.25 7.55
Inlet pressure
p (mbar) 50
(4) Injection pressure
(mbar) 37.0 30.0 34.0 36.0 44.0
(6) Mass flow rate
M (kg/h) 0.220 0.300 0.335 0.455 0.550
Ø orifices (1/100 mm)
Primary orifice (restrictor) 100 110 130 155 210
Orifice (injector) 78 100 105 120 130
Combustion air (m3/h) 2.60 3.60 4.00 5.40 6.50
Required air renewal
(m3/h) 28 38 42.5 58 70

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(3) Hs = Gross calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.2- B ... M CE (AUSTRIA)

B6 B8 B10 B12 B16


CE certificate number 1312AP230 1312AP231 1312AP232
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H AT


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
(3) Qn (Hs) (kW) 2.80 3.65 4.25 5.65 7.50
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal
3
(m /h) 25 33 38 51 67.5

Gas : G30/G31 (propane) Category : I3B/P AT


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.80 3.80 4.25 5.80 7.00
(3) Qn (Hs) (kW) 3.05 4.10 4.60 6.25 7.55
Inlet pressure
p (mbar) 50
(4) Injection pressure
(mbar) 37.0 30.0 34.0 36.0 44.0
(6) Mass flow rate
M (kg/h) 0.220 0.300 0.335 0.455 0.550
Ø orifices (1/100 mm)
Primary orifice (restrictor) 100 110 130 155 210
Orifice (injector) 78 100 105 120 130
Combustion air (m3/h) 2.60 3.60 4.00 5.40 6.50
Required air renewal
(m3/h) 28 38 42.5 58 70

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(3) Hs = Gross calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.3- B ... M CE (BELGIUM)

B6 B8 B10 B12 B16


CE certificate number 1312AP230 1312AP231 1312AP232
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20/G25 (natural gas) Category : I2E+ BE


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 20 (G20) / 25 (G25)
(4) Injection pressure
(mbar) 13.0/16.0 11.0/14.0 12.0/16.0 15.0/18.0 16.7/21.0
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

Gas : G31 (propane) Category : I3P BE


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 -
Orifice (injector) 82 105 110 125 135
Combustion air (m3/h) 2.30 3.10 3.60 4.80 6.30
Required air renewal
(m3/h) 25 33 38 51 67.5

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.4- B ... M CE (DENMARK)

B6 B8 B10 B12 B16


CE certificate number 1312AP230 1312AP231 1312AP232
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H DK


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal see local regulations

Gas : G30/G31 (propane) Category : I3B/P DK


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.40 3.80 4.10 5.10 5.90
Inlet pressure
p (mbar) 30
(4) Injection pressure
(mbar) 30.0 30.0 30.0 30.0 30.0
(6) Mass flow rate
M (kg/h) 0.190 0.300 0.320 0.400 0.460
Ø orifices (1/100 mm)
Primary orifice (restrictor) - - - - -
Orifice (injector) 78 100 105 120 130
Combustion air (m3/h) 2.20 3.50 3.80 4.70 5.40
Required air renewal see local regulations

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.5- B ... M CE (SPAIN)

B6 B8 B10 B12 B16


CE certificate number 1312AP230 1312AP231 1312AP232
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H ES


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

Gas : G31 (propane) Category : I3P ES


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 -
Orifice (injector) 82 105 110 125 135
Combustion air (m3/h) 2.30 3.10 3.60 4.80 6.30
Required air renewal
(m3/h) 25 33 38 51 67.5

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.6- B ... M CE (FINLAND)

B6 B8 B10 B12 B16


CE certificate number 1312AP230 1312AP231 1312AP232
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H FI


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

Gas : G31 (propane) Category : I3P FI


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 -
Orifice (injector) 82 105 110 125 135
Combustion air (m3/h) 2.30 3.10 3.60 4.80 6.30
Required air renewal
(m3/h) 25 33 38 51 67.5

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.7- B ... M CE (FRANCE)

B6 B8 B10 B12 B16


CE certificate number 1312AP230 1312AP231 1312AP232
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2Esi FR


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

Gas : G25 (natural gas type L) Category : I2Esi FR


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 25
(4) Injection pressure
(mbar) 12.0 10.0 10.5 15.5 13.0
(5) Volumetric flow rate
V (m3/h) 0.310 0.400 0.470 0.630 0.830
Ø orifices (1/100 mm)
Primary orifice (restrictor) 160 180 185 220 250
Orifice (injector) 150 185 190 200 235
Combustion air (m3/h) 2.60 3.40 4.00 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

Gas : G31 (propane) Category : I3P FR


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 -
Orifice (injector) 82 105 110 125 135
Combustion air (m3/h) 2.30 3.10 3.60 4.80 6.30
Required air renewal
(m3/h) 25 33 38 51 67.5

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.8- B ... M CE (GREAT BRITAIN / IRELAND)

B6 B8 B10 B12 B16


CE certificate number 1312AP230 1312AP231 1312AP232
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H GB/IE


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

Gas : G31 (propane) Category : I3P GB/IE


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 -
Orifice (injector) 82 105 110 125 135
Combustion air (m3/h) 2.30 3.10 3.60 4.80 6.30
Required air renewal
(m3/h) 25 33 38 51 67.5

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.9- B ... M CE (ITALY)

B6 B8 B10 B12 B16


CE certificate number 1312AP230 1312AP231 1312AP232
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H IT


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

Gas : G31 (propane) Category : I3P IT


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 -
Orifice (injector) 82 105 110 125 135
Combustion air (m3/h) 2.30 3.10 3.60 4.80 6.30
Required air renewal
(m3/h) 25 33 38 51 67.5

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.10- B ... M CE (NETHERLANDS)

B6 B8 B10 B12 B16


CE certificate number 1312AP230 1312AP231 1312AP232
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G25 (natural gas type L) Category : I2L NL


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 25
(4) Injection pressure
(mbar) 12.0 10.0 10.5 15.5 13.0
(5) Volumetric flow rate
V (m3/h) 0.310 0.400 0.470 0.630 0.830
Ø orifices (1/100 mm)
Primary orifice (restrictor) 160 180 185 220 250
Orifice (injector) 150 185 190 200 235
Combustion air (m3/h) 2.60 3.40 4.00 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
3- SBM CATALOGUE
3.1.6.11- B ... M CE (PORTUGAL)

B6 B8 B10 B12 B16


CE certificate number 1312AP230 1312AP231 1312AP232
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H PT


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

Gas : G31 (propane) Category : I3P PT


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 -
Orifice (injector) 82 105 110 125 135
Combustion air (m3/h) 2.30 3.10 3.60 4.80 6.30
Required air renewal
(m3/h) 25 33 38 51 67.5

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.12- B ... M CE (SWEDEN)

B6 B8 B10 B12 B16


CE certificate number 1312AP230 1312AP231 1312AP232
NOx class 4 (≤ 100 mg/kWh)
Radiant efficiency class 2 (>50%)
Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H SE


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal see local regulations

Gas : G30/G31 (propane) Category : I3B/P SE


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.40 3.80 4.10 5.10 5.90
Inlet pressure
p (mbar) 30
(4) Injection pressure
(mbar) 30.0 30.0 30.0 30.0 30.0
(6) Mass flow rate
M (kg/h) 0.190 0.300 0.320 0.400 0.460
Ø orifices (1/100 mm)
Primary orifice (restrictor) - - - - -
Orifice (injector) 78 100 105 120 130
Combustion air (m3/h) 2.20 3.50 3.80 4.70 5.40
Required air renewal see local regulations

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.13- B ... M AU (AUSTRALIA / NEW ZEALAND)

B6 B8 B10 B12 B16


Gas inlet connection R1/2" (ISO 7/1)

Gas : NG (natural gas)


(1) Nominal heat input
Qn (MJ/h) 9.00 12.60 14.00 18.90 25.20
Inlet pressure
p (kPa) 1.50
(4) Injection pressure
(kPa) 1.50 1.10 1.20 1.50 1.50
Ø orifices (mm)
Primary orifice (restrictor) - 2.10 2.60 - -
Orifice (injector) 1.35 1.65 1.70 1.80 2.10

Gas : G31 (propane)


(1) Nominal heat input
Qn (MJ/h) 9.00 12.60 14.00 18.90 25.20
Inlet pressure
p (kPa) 2.75
(4) Injection pressure
(kPa) 2.75 2.75 2.45 2.75 2.75
Ø orifices (mm)
Primary orifice (restrictor) - - 2.10 - -
Orifice (injector) 0.82 1.05 1.10 1.25 1.40

(1) Nominal heat input Qn = Nominal capacity


(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
3- SBM CATALOGUE
3.1.6.14- B ... M IE (INTERNATIONAL)

B6 B8 B10 B12 B16


Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2Esi


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

Gas : G31 (propane) Category : I3P


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 -
Orifice (injector) 82 105 110 125 135
Combustion air (m3/h) 2.30 3.10 3.60 4.80 6.30
Required air renewal
(m3/h) 25 33 38 51 67.5

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.15- B ... M CH (SWITZERLAND)

B6 B8 B10 B12 B16


Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : II2H3P


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 170 180 195 240 320
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

Gas : G31 (propane) Category : II2H3P


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 37
(4) Injection pressure
(mbar) 34.0 21.0 21.0 28.0 37.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530
Ø orifices (1/100 mm)
Primary orifice (restrictor) 155 140 130 180 -
Orifice (injector) 82 105 110 125 135
Combustion air (m3/h) 2.30 3.10 3.60 4.80 6.30
Required air renewal
(m3/h) 25 33 38 51 67.5

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.1.6.16- B ... M RU (RUSSIA)

B6 B8 B10 B12 B16


Gas inlet connection G1/2" (ISO 228/1)

Gas : G20 (natural gas type H) Category : I2H


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 20
(4) Injection pressure
(mbar) 13.0 11.0 12.0 15.0 16.7
(5) Volumetric flow rate
V (m3/h) 0.265 0.350 0.400 0.540 0.715
Ø orifices (1/100 mm)
Primary orifice (restrictor) 195 200 210 300 -
Orifice (injector) 135 165 170 180 195
Combustion air (m3/h) 2.60 3.40 3.90 5.30 7.00
Required air renewal
(m3/h) 25 33 38 51 67.5

Gas : G31 (propane) Category : I3P


(1) Nominal heat input
(2) Qn (Hi) (kW) 2.50 3.30 3.80 5.10 6.75
Inlet pressure
p (mbar) 30
(4) Injection pressure
(mbar) 30.0 21.0 21.0 28.0 30.0
(6) Mass flow rate
M (kg/h) 0.195 0.260 0.300 0.400 0.530
Ø orifices (1/100 mm)
Primary orifice (restrictor) - 130 145 220 -
Orifice (injector) 82 105 110 125 137
Combustion air (m3/h) 2.30 3.10 3.60 4.80 6.30
Required air renewal
(m3/h) 25 33 38 51 67.5

(1) Nominal heat input Qn = Nominal capacity


(2) Hi = Net calorific value (see 10.3.1)
(4) Injection pressure : all SBM heaters are equipped with a pressure test point to control the injection pressure
(see 4.8.2.3)
(5) Volumetric flow rate V = Natural gas consumption
(6) Mass flow rate M = Propane gas consumption
3- SBM CATALOGUE
3.2- CONTROL MODULES
3.2.1- TEMPERATURE CONTROLS

MT 100 ........................ 3.2.1.1

MT 100 DE .................. 3.2.1.2

MT 150 ........................ 3.2.1.3

MT 150 DE .................. 3.2.1.4

Related sections :

Ceramic heaters..........................................................................3.1
Accessories ................................................................................3.3
Installation......................................................................................4
Operation........................................................................................5
Maintenance ...................................................................................6
Trouble-shooting ...........................................................................7
Spare parts.....................................................................................8
Applications ...................................................................................9
3- SBM CATALOGUE
3.2.1.1- MT 100
Single speed control module for SBM automatic heaters.

CONTENTS OF BOX

75 mm
DIN rail 35 mm
(not supplied)

Other units : see (10.1)


84 mm

143 mm

Power supply 230V (+10% , -15%) / 50Hz - 60Hz


Temperature display range -5°C to 52°C
Setpoint range 0°C to 47°C by step of 1°C
Output 1 solenoid valve output : 1A maxi, 0.01A mini
1 heater output : 4A maxi (40 BA blocks), 0.1A mini (1 BA block)
(heater output with 45 second timer)
Ventilation safety 1 output for connection of a heating cut-off safety switch (Normally Closed)
(see 5.3)
Operating temperature ranges Control box : 0°C to 40°C - Sensor : -10°C to 60°C
Assembly On 35mm DIN symmetrical rail, in IP555 casing (not supplied)
To be protected in compliance with local electrical standards.
Module - sensor connection Use the SBM cable : ROLL SENSOR CABLE (see 3.3.2.4)
3- SBM CATALOGUE
3.2.1.2- MT 100 DE
Single speed control module for SBM automatic heaters.

CONTENTS OF BOX

75 mm
DIN rail 35 mm
(not supplied)

Other units : see (10.1)


84 mm

143 mm

Power supply 230V (+10% , -15%) / 50Hz - 60Hz


Temperature display range -5°C to 52°C
Setpoint range 0°C to 47°C by step of 1°C
Output 1 solenoid valve output : 4A maxi, 0.1A mini
1 heater output : 4A maxi (40 BA blocks), 0.1A mini (1 BA block)
(heater output with 45 second timer)
Ventilation safety 1 output for connection of a heating cut-off safety switch (Normally Closed)
(see 5.3)
Operating temperature ranges Control box : 0°C to 40°C - Sensor : -10°C to 60°C
Assembly On 35mm DIN symmetrical rail, in IP555 casing (not supplied)
To be protected in compliance with local electrical standards.
Module - sensor connection Use the SBM cable : ROLL SENSOR CABLE (see 3.3.2.4)
3- SBM CATALOGUE
3.2.1.3- MT 150
Double speed control module for SBM automatic heaters.

CONTENTS OF BOX

75 mm
DIN rail 35 mm
(not supplied)

Other units : see (10.1)


84 mm

143 mm

Power supply 230V (+10% , -15%) / 50Hz - 60Hz


Temperature display range -5°C to 52°C
Setpoint range 0°C to 47°C by step of 1°C
Delta 50% - 100% 1°C to 3°C by step of 0.5°C. Preset to 1°C.
Output 1 solenoid valve output : 1A maxi, 0.01A mini
1 heater output 50% : 4A maxi (40 BA blocks), 0.1A mini (1 BA block)
1 heater output 100% : 4A maxi (40 BA blocks), 0.1A mini (1 BA block)
(heater outputs with 45 second timer)
Ventilation safety 1 output for connection of a heating cut-off safety switch (Normally Closed)
(see 5.3)
Operating temperature ranges Control box : 0°C to 40°C - Sensor : -10°C to 60°C
Assembly On 35mm DIN symmetrical rail, in IP555 casing (not supplied)
To be protected in compliance with local electrical standards.
Module - sensor connection Use the SBM cable : ROLL SENSOR CABLE (see 3.3.2.4)
3- SBM CATALOGUE
3.2.1.4- MT 150 DE
Double speed control module for SBM automatic heaters.

CONTENTS OF BOX

75 mm
DIN rail 35 mm
(not supplied)

Other units : see (10.1)


84 mm

143 mm

Power supply 230V (+10% , -15%) / 50Hz - 60Hz


Temperature display range -5°C to 52°C
Setpoint range 0°C to 47°C by step of 1°C
Delta 50% - 100% 1°C to 3°C by step of 0.5°C. Preset to 1°C.
Output 1 solenoid valve output 50% : 4A maxi, 0.1A mini
1 solenoid valve output 100%: 4A maxi, 0.1A mini
1 heater output : 4A maxi (40 BA blocks), 0.1A mini (1 BA block)
(heater output with 45 second timer)
Ventilation safety 1 output for connection of a heating cut-off safety switch (Normally Closed)
(see 5.3)
Operating temperature ranges Control box : 0°C to 40°C - Sensor : -10°C to 60°C
Assembly On 35mm DIN symmetrical rail, in IP555 casing (not supplied)
To be protected in compliance with local electrical standards.
Module - sensor connection Use the SBM cable : ROLL SENSOR CABLE (see 3.3.2.4)
3- SBM CATALOGUE
3.2.2- TEMPERATURE CONTROLS WITH PROGRAMMING

MTH 100...................... 3.2.2.1

MTH 100 DE................ 3.2.2.2

MTH 150...................... 3.2.2.3

MTH 150 DE................ 3.2.2.4

Related sections :

Ceramic heaters..........................................................................3.1
Accessories ................................................................................3.3
Installation......................................................................................4
Operation........................................................................................5
Maintenance ...................................................................................6
Trouble-shooting ...........................................................................7
Spare parts.....................................................................................8
Applications ...................................................................................9
3- SBM CATALOGUE
3.2.2.1- MTH 100
Single speed control module for SBM automatic heaters with clock and yearly programming.

CONTENTS OF BOX

75 mm
DIN rail 35 mm
(not supplied)

Other units : see (10.1)


84 mm

143 mm

Power supply 230V (+10% , -15%) / 50Hz - 60Hz


Temperature display range -5°C to 52°C in 0.1°C steps
Setpoints Tc : Confort temperature Tr : Reduced temperature Tn : Night temperature
Setpoint range 0°C to 47°C by step of 1°C
Programming Weekly : 7 steps (numbered 1 to 7) per day
Yearly : 10 exceptional dates (numbered 1 to 10)
1 exceptional period and 2 exceptional programmes
Output 1 solenoid valve output : 1A maxi, 0.01A mini
1 heater output : 4A maxi (40 BA blocks), 0.1A mini (1 BA block)
(heater output with 45 second timer)
Decentralised override on switch 1 output for connection of an external push-button (Normally Open)
enabling the regulation mode to be changed (to go into override On)
Ventilation safety 1 output for connection of a heating cut-off safety switch (Normally Closed)
(see 5.3)
Back-up battery Clock and programmes : 6 months minimum
Heating period counter Max. 9999 hours and 59 minutes with automatic reset
Operating temperature ranges Control box : 0°C to 40°C - Sensor : -10°C to 60°C
Assembly On 35mm DIN symmetrical rail, in IP555 casing (not supplied)
To be protected in compliance with local electrical standards.
Module - sensor connection Use the SBM cable : ROLL SENSOR CABLE (see 3.3.2.4)
3- SBM CATALOGUE
3.2.2.2- MTH 100 DE
Single speed control module for SBM automatic heaters with clock and yearly programming.

CONTENTS OF BOX

75 mm
DIN rail 35 mm
(not supplied)

Other units : see (10.1)


84 mm

143 mm

Power supply 230V (+10% , -15%) / 50Hz - 60Hz


Temperature display range -5°C to 52°C in 0.1°C steps
Setpoints Tc : Confort temperature Tr : Reduced temperature Tn : Night temperature
Setpoint range 0°C to 47°C by step of 1°C
Programming Weekly : 7 steps (numbered 1 to 7) per day
Yearly : 10 exceptional dates (numbered 1 to 10)
1 exceptional period and 2 exceptional programmes
Output 1 solenoid valve output : 4A maxi, 0.1A mini
1 heater output : 4A maxi (40 BA blocks), 0.1A mini (1 BA block)
(heater output with 45 second timer)
Decentralised override on switch 1 output for connection of an external push-button (Normally Open)
enabling the regulation mode to be changed (to go into override On)
Ventilation safety 1 output for connection of a heating cut-off safety switch (Normally Closed)
(see 5.3)
Back-up battery Clock and programmes : 6 months minimum
Heating period counter Max. 9999 hours and 59 minutes with automatic reset
Operating temperature ranges Control box : 0°C to 40°C - Sensor : -10°C to 60°C
Assembly On 35mm DIN symmetrical rail, in IP555 casing (not supplied)
To be protected in compliance with local electrical standards.
Module - sensor connection Use the SBM cable : ROLL SENSOR CABLE (see 3.3.2.4)
3- SBM CATALOGUE
3.2.2.3- MTH 150
Double speed control module for SBM automatic heaters with clock and yearly programming.

CONTENTS OF BOX

75 mm
DIN rail 35 mm
(not supplied)

Other units : see (10.1)


84 mm

143 mm

Power supply 230V (+10% , -15%) / 50Hz - 60Hz


Temperature display range -5°C to 52°C in 0.1°C steps
Setpoints Tc : Confort temperature Tr : Reduced temperature Tn : Night temperature
Setpoint range 0°C to 47°C by step of 1°C
Delta 50% - 100% 1°C to 3°C by step of 0.5°C. Preset to 1°C.
Programming Weekly : 7 steps (numbered 1 to 7) per day
Yearly : 10 exceptional dates (numbered 1 to 10)
1 exceptional period and 2 exceptional programmes
Output 1 solenoid valve output : 1A maxi, 0.01A mini
1 heater output 50% : 4A maxi (40 BA blocks), 0.1A mini (1 BA block)
1 heater output 100% : 4A maxi (40 BA blocks), 0.1A mini (1 BA block)
(heater outputs with 45 second timer)
Decentralised override on switch 1 output for connection of an external push-button (Normally Open)
enabling the regulation mode to be changed (to go into override On)
Ventilation safety 1 output for connection of a heating cut-off safety switch (Normally Closed)
(see 5.3)
Back-up battery Clock and programmes : 6 months minimum
Heating period counter Max. 9999 hours and 59 minutes with automatic reset
Operating temperature ranges Control box : 0°C to 40°C - Sensor : -10°C to 60°C
Assembly On 35mm DIN symmetrical rail, in IP555 casing (not supplied)
To be protected in compliance with local electrical standards.
Module - sensor connection Use the SBM cable : ROLL SENSOR CABLE (see 3.3.2.4)
3- SBM CATALOGUE
3.2.2.4- MTH 150 DE
Double speed control module for SBM automatic heaters with clock and yearly programming.

CONTENTS OF BOX

75 mm
DIN rail 35 mm
(not supplied)

Other units : see (10.1)

84 mm

143 mm

Power supply 230V (+10% , -15%) / 50Hz - 60Hz


Temperature display range -5°C to 52°C in 0.1°C steps
Setpoints Tc : Confort temperature Tr : Reduced temperature Tn : Night temperature
Setpoint range 0°C to 47°C by step of 1°C
Delta 50% - 100% 1°C to 3°C by step of 0.5°C. Preset to 1°C.
Programming Weekly : 7 steps (numbered 1 to 7) per day
Yearly : 10 exceptional dates (numbered 1 to 10)
1 exceptional period and 2 exceptional programmes
Output 1 solenoid valve output 50% : 4A maxi, 0.1A mini
1 solenoid valve output 100%: 4A maxi, 0.1A mini
1 heater output : 4A maxi (40 BA blocks), 0.1A mini (1 BA block)
(heater output with 45 second timer)
Decentralised override on switch 1 output for connection of an external push-button (Normally Open)
enabling the regulation mode to be changed (to go into override On)
Ventilation safety 1 output for connection of a heating cut-off safety switch (Normally Closed)
(see 5.3)
Back-up battery Clock and programmes : 6 months minimum
Heating period counter Max. 9999 hours and 59 minutes with automatic reset
Operating temperature ranges Control box : 0°C to 40°C - Sensor : -10°C to 60°C
Assembly On 35mm DIN symmetrical rail, in IP555 casing (not supplied)
To be protected in compliance with local electrical standards.
Module - sensor connection Use the SBM cable : ROLL SENSOR CABLE (see 3.3.2.4)
3- SBM CATALOGUE
3.3- ACCESSORIES
3.3.1- GAS ACCESSORIES

VDF G31-37 Rp1/2-G1/2m ................ 3.3.1.1


VDF G20-20 Rp1/2-G1/2m ................ 3.3.1.2

VDF G25-25 Rp1/2-G1/2m ................ 3.3.1.3

VDF G30/31-30 Rp1/2-G1/2m ........... 3.3.1.4

DF64 G1/2 G31-37 4KG/H ................. 3.3.1.5


DF64 G1/2 G20-20 3M3/H ................. 3.3.1.6

DF64 G1/2 G25-25 3M3/H ................. 3.3.1.7

DF64 G1/2 G30/31-30 5KG/H ............ 3.3.1.8

Rp1/2 DN15 VALVE .......................... 3.3.1.9

LOW PRESSURE VALVE ............... 3.3.1.10

GAS FILTER DN20 Rp 3/4" ............. 3.3.1.11


GAS FILTER DN25 Rp 1" ................ 3.3.1.12

GAS FILTER DN32 Rp 1" 1/4 .......... 3.3.1.13

GAS FILTER DN40 Rp 1" 1/2 .......... 3.3.1.14


3- SBM CATALOGUE

GAS FILTER F40 G1/2m ................. 3.3.1.15

SOL.VALVE 8X13 - Rp 1/4" ............. 3.3.1.16


SOL.VALVE 15X21 - Rp 1/2" ........... 3.3.1.17

SOL.VALVE 20X27 - Rp 3/4" ........... 3.3.1.18

SOL.VALVE 26X34 - Rp 1" .............. 3.3.1.19

SOL.VALVE 33X42 - Rp 1 1/4" ........ 3.3.1.20

SOL.VALVE 40X49 - Rp 1 1/2" ........ 3.3.1.21

SOL.VALVE 50X60 - Rp 2" .............. 3.3.1.22

FITTING FOR SOLDERING 12 G1/2 3.3.1.23

FITTING FOR SOLDERING 14 G1/2 3.3.1.24

UNION FITTING R1/2m-G1/2m ........ 3.3.1.25

UNION FITTING 12GM/M20F .......... 3.3.1.26


3- SBM CATALOGUE

UNION FITTING 12GF/M20M .......... 3.3.1.27

T FITTING MALE G1/2 .................... 3.3.1.28

SLEEVE F/F G1/2 ............................ 3.3.1.29

VITON WASHER G1/2 ..................... 3.3.1.30

METALLIC HOSE G1/2F 700mm..... 3.3.1.31

FLEXIBLE HOSE G1/2F ERP 750mm

.......................................................... 3.3.1.32
3- SBM CATALOGUE

FLEXIBLE HOSE 500MM 1/2M 1/2F 3.3.1.33

THERMAL FUSE ............................. 3.3.1.34

GAS SUPPLY KIT G20/25 1 SPEED 3.3.1.35

GAS SUPPLY KIT G20/25 2 SPEED 3.3.1.36

REG 1/2F I20-100 O12-30MBAR

.......................................................... 3.3.1.37

KOMBI KIT G20/G25 2 SPEED ....... 3.3.1.38

GAS SUPPLY KIT PROPANE

1 SPEED ........................................... 3.3.1.39


3- SBM CATALOGUE

GAS SUPPLY KIT PROPANE

2 SPEED ........................................... 3.3.1.40

FITTING FOR SOLDERING 12 G1/2

.......................................................... 3.3.1.41

FITTING G1/2F - FERRULE 12MM . 3.3.1.42

90° ELBOW G1/2F - FERRULE 12MM

.......................................................... 3.3.1.43

Related sections :

Ceramic heaters..........................................................................3.1
Control modules .........................................................................3.2
Installation......................................................................................4
Operation........................................................................................5
Maintenance ...................................................................................6
Trouble-shooting ...........................................................................7
Spare parts.....................................................................................8
Applications ...................................................................................9
3- SBM CATALOGUE
3.3.1.1- VDF G31-37 Rp1/2-G1/2m

Assembly valve + fixed regulator.

CONTENTS OF KIT

A B C

Gas G31 (Propane)


Pressures : inlet 0.2 bar min, 2.1 bar max
outlet 37 mbar
Maximum capacity 4 kg/h
Fittings : inlet Rp1/2" female (ISO 7/1)
outlet G1/2" male (ISO 228/1)
Total length Approx. 195 mm
Composition (A) : Rp1/2 DN15 VALVE
I/O : Rp1/2" female (ISO 7/1)
(B) : union fitting R1/2m-G1/2m
I : R1/2" male (ISO 7/1)
O : G1/2" male (ISO 228/1)
(C) : DF64 G1/2 G31-37 4KG/H
I : coupling nut G1/2’’ (ISO 228/1) with washer and filter
O : G1/2" male (ISO 228/1)
Application Individual gas supply for all SX and M heaters operating
with G31-37.

Installation : see (4.6.2.1) (4.6.2.2)

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.2- VDF G20-20 Rp1/2-G1/2m

Assembly valve + fixed regulator.

CONTENTS OF KIT

A B C

Gas G20 (Natural gas type H)


Pressures : inlet 0.2 bar min, 1.5 bar max
outlet 20 mbar
Maximum capacity 3 m3/h
Fittings : inlet Rp1/2" female (ISO 7/1)
outlet G1/2" male (ISO 228/1)
Total length Approx. 195 mm
Composition (A) : Rp1/2 DN15 VALVE
I/O : Rp1/2" female (ISO 7/1)
(B) : union fitting R1/2m-G1/2m
I : R1/2" male (ISO 7/1)
O : G1/2" male (ISO 228/1)
(C) : DF64 G1/2 G20-20 3M3/H
I : coupling nut G1/2’’ (ISO 228/1) with washer and filter
O : G1/2" male (ISO 228/1)
Application Individual gas supply for all SX and M heaters operating
with G20-20.

Installation : see (4.6.2.1) (4.6.2.2)

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.3- VDF G25-25 Rp1/2-G1/2m

Assembly valve + fixed regulator.

CONTENTS OF KIT

A B C

Gas G25 (Natural gas type L)


Pressures : inlet 0.2 bar min, 1.5 bar max
outlet 25 mbar
Maximum capacity 3 m3/h
Fittings : inlet Rp1/2" female (ISO 7/1)
outlet G1/2" male (ISO 228/1)
Total length Approx. 195 mm
Composition (A) : Rp1/2 DN15 VALVE
I/O : Rp1/2" female (ISO 7/1)
(B) : union fitting R1/2m-G1/2m
I : R1/2" male (ISO 7/1)
O : G1/2" male (ISO 228/1)
(C) : DF64 G1/2 G25-25 3M3/H
I : coupling nut G1/2’’ (ISO 228/1) with washer and filter
O : G1/2" male (ISO 228/1)
Application Individual gas supply for all SX (except B64) and M heaters
operating with G25-25.
Each B64 heater requires 2 fixed regulators when operating with G25 gas.
Therefore do not use this assembly, but the following accessories :
- 1 x Rp1/2 DN15 VALVE (3.3.1.9)
- 2 x DF64 G1/2 G25-25 3M3/H (3.3.1.7)
- 1 x T FITTING MALE G1/2 (3.3.1.28)
- 1 x UNION FITTING R1/2m-G1/2m (3.3.1.25)
- 1 x SLEEVE F/F G1/2 (3.3.1.29)
- 2 x VITON WASHER G1/2 (3.3.1.30)

Installation : see (4.6.2.1) (4.6.2.2)

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.4- VDF G30/31-30 Rp1/2-G1/2m

Assembly valve + fixed regulator.

CONTENTS OF KIT

A B C

Gas G30/31 (Propane/Butane)


Pressures : inlet 0.2 bar min, 2.1 bar max
outlet 30 mbar
Maximum capacity 5 kg/h
Fittings : inlet Rp1/2" female (ISO 7/1)
outlet G1/2" male (ISO 228/1)
Total length Approx. 195 mm
Composition (A) : Rp1/2 DN15 VALVE
I/O : Rp1/2" female (ISO 7/1)
(B) : union fitting R1/2m-G1/2m
I : R1/2" male (ISO 7/1)
O : G1/2" male (ISO 228/1)
(C) : DF64 G1/2 G31-37 5KG/H
I : coupling nut G1/2’’ (ISO 228/1) with washer and filter
O : G1/2" male (ISO 228/1)
Application Individual gas supply for all SX and M heaters operating
with G30/31-30.

Installation : see (4.6.2.1) (4.6.2.2)

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.5- DF64 G1/2 G31-37 4KG/H

Fixed regulator.

Gas G31 (Propane)


Pressures : inlet 0.2 bar min, 2.1 bar max
outlet 37 mbar
Maximum capacity 4kg/h
Fittings : inlet Coupling nut G1/2’’ (ISO 228/1) with washer and filter
outlet G1/2" male (ISO 228/1)
Application Individual gas supply for all SX and M heaters operating
with G31-37.

3.3.1.6- DF64 G1/2 G20-20 3M3/H

Fixed regulator.

CONTENTS OF BAG

Gas G20 (Natural gas type H)


Pressures : inlet 0.2 bar min, 1.5 bar max
outlet 20 mbar
Maximum capacity 3 m3/h
Fittings : inlet Coupling nut G1/2’’ (ISO 228/1) with washer and filter
outlet G1/2" male (ISO 228/1)
Application Individual gas supply for all SX and M heaters operating
with G20-20.

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.7- DF64 G1/2 G25-25 3M3/H
Fixed regulator.

CONTENTS OF BAG

Gas G25 (Natural gas type L)


Pressures: inlet 0.2 bar min, 1.5 bar max
outlet 25 mbar
Maximum capacity 3 m3/h
Fittings : inlet coupling nut G1/2’’ (ISO 228/1) with washer and filter
outlet G1/2" male (ISO 228/1)
Application Individual gas supply for all SX and M heaters operating
with G25-25.
2 fixed regulators are required for supplying each B64 heater
(see 4.6.2.2)

3.3.1.8- DF64 G1/2 G30/31-30 5KG/H


Fixed regulator.

CONTENTS OF BAG

Gas G30/31 (Propane/Butane)


Pressures: inlet 0.2 bar min, 2.1 bar max
outlet 30 mbar
Maximum capacity 5 kg/h
Fittings : inlet coupling nut G1/2’’ (ISO 228/1) with washer and filter
outlet G1/2" male (ISO 228/1)
Application Individual gas supply for all SX and M heaters operating
with G30/31-30

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.9- Rp1/2 DN15 VALVE

1/4 turn gas ball-valve

Operating pressure 0 to 4 bar


Fittings : inlet / outlet Rp1/2" female (ISO 7/1)
Application Individual valve for all SX and M heaters.

3.3.1.10- LOW PRESSURE VALVE

1/4 turn gas valve (low pressure) for 12 x 14 copper piping.

CONTENTS OF BAG

2X

Gas / pressure G20 (Natural gas type H) / 20 mbar


G25 (Natural gas type L) / 25 mbar
G31 (Propane gas) / 37 mbar
Fittings : inlet / outlet 12x14 fittings for soldering + G1/2" (ISO228/1) washer + 12x14
G1/2" nut (ISO228/1)
Application Individual gas supply in low pressure installations for all SX
and M heaters

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.11- GAS FILTER DN20 Rp 3/4"

Gas filter

CONTENTS OF BOX

Gas All types


Operating pressure 4 bar max.
Fittings : inlet / outlet Rp 3/4" female (ISO7/1)
Filtration media Washable in water (max. temperature : 40°C)
Filtration limit : 50 µm
Application Filter for installation of all SX and M heaters

3.3.1.12- GAS FILTER DN25 Rp 1"

Gas filter

CONTENTS OF BOX

Gas All types


Operating pressure 4 bar max.
Fittings : inlet / outlet Rp 1" female (ISO7/1)
Filtration media Washable in water (max. temperature : 40°C)
Filtration limit : 50 µm
Application Filter for installation of all SX and M heaters

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.13- GAS FILTER DN32 Rp 1" 1/4

Gas filter

CONTENTS OF BOX

Gas All types


Operating pressure 4 bar max.
Fittings : inlet / outlet Rp 1 1/4" female (ISO7/1)
Filtration media Washable in water (max. temperature : 40°C)
Filtration limit : 50 µm
Application Filter for installation of all SX and M heaters

3.3.1.14- GAS FILTER DN40 Rp 1" 1/2

Gas filter

CONTENTS OF BOX

Gas All types


Operating pressure 4 bar max.
Fittings : inlet / outlet Rp 1 1/2" female (ISO7/1)
Filtration media Washable in water (max. temperature : 40°C)
Filtration limit : 50 µm
Application Filter for installation of all SX and M heaters

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.15- GAS FILTER F40 G1/2m

Gas filter

Gas G31 (Propane)


Operating pressure 20 bar max.
Fittings : inlet / outlet G1/2" male (ISO228/1)
Filtration media Nylon cartridge
Filtration limit : 80 µm
Application Filter for installation of all SX and M heaters

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.16- SOL.VALVE 8X13 - Rp 1/4"

Solenoid valve

CONTENTS OF BOX

CONTENTS OF
CONNECTOR BAG

Operation Normally closed (NC)


Gas All types
Maximum operating pressure 40 bar
Minimum differential pressure 0 bar
Kv flow coefficient 10.5 l/mn
Fittings : - inlet Rp 1/4" female (ISO7/1) marked 1
- outlet Rp 1/4" female (ISO7/1) marked 2
Width 40 mm
Power supply 230V / 50Hz
Capacity : - maximum 23 VA
- stable 14 VA (8W)
Coil : - watertightness IP65
- insulation Class F
Recommended mounting Horizontal flow, coil on top of the valve
Application Solenoid valve for installation of all SX heaters

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.17- SOL.VALVE 15X21 - Rp 1/2"

Solenoid valve

CONTENTS OF BOX

CONTENTS OF
CONNECTOR BAG

Operation Normally closed (NC)


Gas All types
Maximum operation pressure 16 bar
Minimum differential pressure 0 bar
Kv flow coefficient 47 l/mn
Fittings : - inlet Rp 1/2" female (ISO7/1)
- outlet Rp 1/2" female (ISO7/1)
Flow direction marked by an arrow
Width 74.5 mm
Power supply 230V / 50Hz
Capacity : - maximum 100 VA
- stable 25 VA (10 W)
Coil : - watertightness IP65
- insulation Class H
Recommended mounting Horizontal flow, coil on top of the valve
Application Solenoid valve for installation of all SX heaters

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.18- SOL.VALVE 20X27 - Rp 3/4"

Solenoid valve

CONTENTS OF BOX

CONTENTS OF
CONNECTOR BAG

Operation Normally closed (NC)


Gas All types
Maximum operation pressure 16 bar
Minimum differential pressure 0 bar
Kv flow coefficient 83 l/mn
Fittings : - inlet Rp 3/4" female (ISO7/1)
- outlet Rp 3/4" female (ISO7/1)
Flow direction marked by an arrow
Width 100 mm
Power supply 230V / 50Hz
Capacity : - maximum 120 VA
- stable 32 VA (16 W)
Coil : - watertightness IP65
- insulation Class H
Recommended mounting Horizontal flow, coil on top of the valve
Application Solenoid valve for installation of all SX heaters

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.19- SOL.VALVE 26X34 - Rp 1"

Solenoid valve

CONTENTS OF BOX

CONTENTS OF
CONNECTOR BAG

Operation Normally closed (NC)


Gas All types
Maximum operating pressure 16 bar
Minimum differential pressure 0 bar
Kv flow coefficient 167 l/mn
Fittings : - inlet Rp 1" female (ISO7/1)
- outlet Rp 1" female (ISO7/1)
Flow direction marked by an arrow
Width 115 mm
Power supply 230V / 50Hz
Capacity : - maximum 120 VA
- stable 32 VA (16 W)
Coil : - watertightness IP65
- insulation Class H
Recommended mounting Horizontal flow, coil on top of the valve
Application Solenoid valve for installation of all SX radiants

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.20- SOL.VALVE 33X42 - Rp 1 1/4"

Solenoid valve

CONTENTS OF BOX

CONTENTS OF
CONNECTOR BAG

Operation Normally closed (NC)


Gas All types
Maximum operating pressure 9 bar
Minimum differential pressure 0 bar
Kv flow coefficient 213 l/mn
Fittings : - inlet Rp 1 1/4" female (ISO7/1) marked IN
- outlet Rp 1 1/4" female (ISO7/1) unmarked
Width 95 mm
Power supply 230V / 50Hz
Capacity : - maximum 110 VA
- stable 33.6 VA (15.4W)
Coil : - watertightness IP65
- insulation Class F
Recommended mounting Horizontal flow, coil on top of the valve
Application Solenoid valve for installation of all SX radiants

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.21- SOL.VALVE 40X49 - Rp 1 1/2"

Solenoid valve

CONTENTS OF BOX

CONTENTS OF
CONNECTOR BAG

Operation Normally closed (NC)


Gas All types
Maximum operating pressure 9 bar
Minimum differential pressure 0 bar
Kv flow coefficient 322 l/mn
Fittings : - inlet Rp 1 1/2" female (ISO7/1) marked IN
- outlet Rp 1 1/2" female (ISO7/1) marked OUT
Width 111 mm
Power supply 230V / 50Hz
Capacity : - maximum 110 VA
- stable 33.6 VA (15.4W)
Coil : - watertightness IP65
- insulation Class F
Recommended mounting Horizontal flow, coil on top of the valve
Application Solenoid valve for installation of all SX radiants

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.22- SOL.VALVE 50X60 - Rp 2"

Solenoid valve

CONTENTS OF BOX

CONTENTS OF
CONNECTOR BAG

Operation Normally closed (NC)


Gas All types
Maximum operating pressure 1 bar
Minimum differential pressure 0 bar
Kv flow coefficient 833 l/mn
Fittings : - inlet Rp 2" female (ISO7/1) marked IN
- outlet Rp 2" female (ISO7/1) marked
Width 155 mm
Power supply 230V / 50Hz
Capacity : - maximum 110 VA
- stable 33.6 VA (15.4W)
Coil : - watertightness IP65
- insulation Class F
Recommended mounting Horizontal flow, coil on top of the valve
Application Solenoid valve for installation of all SX radiants

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.23- FITTING FOR SOLDERING 12 G1/2

Fitting for soldering 2 parts + washer

Composition
C A B 1 fitting for soldering for copper
tube 10x12 mm (A)
1 G1/2" nut (ISO228/1) (B)
1 viton washer (C)

Application Connecting SX and M heaters to 12 mm OD


copper piping.

3.3.1.24- FITTING FOR SOLDERING 14 G1/2

Fitting for soldering 2 parts + washer

Composition
C A B 1 fitting for soldering for copper
tube 12x14 mm (A)
1 G1/2" nut (ISO228/1) (B)
1 viton washer (C)

Application Connecting SX and M heaters to 14 mm OD


copper piping.

3.3.1.25- UNION FITTING R1/2m-G1/2m

Union fitting R1/2’’ male (ISO7/1) - G1/2" male (ISO228/1)

Application Connecting Rp1/2 DN15 valve to fixed regulator


(medium pressure) or to metallic hose
(low pressure)

Installation : see (4.6.2.1) (4.6.2.2)

3.3.1.26- UNION FITTING 12GM/M20F

Union fitting G1/2’’ male (ISO228/1) – M20x1.5 female (ISO68-1) with built-in washer

Application Fitting M20x1.5 male


to G1/2" cylindrical male

Autres unités: see


Other units : voir(10.1)
(10.1)
3- SBM CATALOGUE
3.3.1.27- UNION FITTING 12GF/M20M

Union fitting G1/2" female (ISO228/1) - M20x1.5 (ISO68-1) male with built-in washer

Application Fitting G1/2" cylindrical


male to M20x1.5 male

3.3.1.28- T FITTING MALE G1/2

Triple T G1/2" male (ISO228/1)

Application Connecting double speed SX heaters

3.3.1.29- SLEEVE F/F G1/2

Sleeve G1/2" female (ISO228/1) with seats for washers (not included)

Application Connecting double speed SX heaters

3.3.1.30- VITON WASHER G1/2

G1/2" viton washer for sleeve f/f 12G

Application Connecting double speed SX heaters

Installation : see (4.6.2.2)

Autres unités: see


Other units : voir(10.1)
(10.1)
3- SBM CATALOGUE
3.3.1.31- METALLIC HOSE G1/2F 700mm

Flexible hose DN12 – 700 mm

Gas All types


Operating pressure 2.5 bar max.
Fittings : inlet / outlet G1/2" female (ISO228/1) coupling nut with viton washer
Length 700 mm
Application Gas connection of all SX and M heaters installed in
industrial and commercial buildings

3.3.1.32- METALLIC HOSE G1/2F ERP 750mm

Flexible hose DN12 - 750 mm

In FRANCE, only type of flexible hose


allowed in public buildings.

Gas All types


Operating pressure 2 bar max.
Fittings : inlet / outlet G1/2" female (ISO228/1) coupling nut with viton washer
Length 750 mm
Application Gas connection of all SX and M heaters installed in
public buildings (France only)

Installation : see (4.6.2.1) (4.6.2.2)

Autres unités: see


Other units : voir(10.1)
(10.1)
3- SBM CATALOGUE
3.3.1.33- FLEXIBLE HOSE 500 1/2M 1/2F

Flexible hose DN12 - 500 mm

Gas All types


Operating pressure 4 bar max.
Fittings : - inlet R1/2" male (ISO7/1)
- outlet Rp1/2" female (ISO7/1)
Length 500 mm
Application Gas connection for all SX, KOMFORT and M heaters.
(Not authorized in public buildings in France)

3.3.1.34- THERMAL FUSE

Thermal safety valve DN15

Gas All types


Temperatures :
- operation 80°C max.
- melting 100°C
Fittings : - inlet Rp1/2" female (ISO7/1)
- outlet R1/2" male (ISO7/1)
Total length 58 mm
Application Gas connection for all SX, KOMFORT and M heaters

Installation : see (4.6.2)

Autres
Other units
unités: see
: voir(10.1)
(10.1)
3- SBM CATALOGUE
3.3.1.35- GAS SUPPLY KIT G20/25 1 SPEED (RS AME EG)

Natural gas supply kit

COMPOSITION OF KIT

B
A

C
CONTENTS OF
CONNECTOR BAG

Gas Natural gas G20 and G25


Pressures : - inlet 20 mbar mini, 100 mbar maxi
- outlet Ajustable from 12.5 to 30 mbar
Fittings : - inlet Rp 1/2" female (ISO 7/1) (valve inlet)
- outlet Rp 1/2" female (ISO 7/1) (solenoid valve outlet)
Power supply 230V / 50Hz
Capacity 10 W
Composition (A) : Rp1/2 DN15 VALVE 1/4 turn gas ball-valve
I/O : Rp1/2" female (ISO 7/1)
(B) : REG 1/2F I 20-100 O 12.5-30 MBAR
I/O : Rp1/2" female (ISO 7/1)
Recommended position : horizontal flow
(C) : SOL. VALVE NC 2WAY 1/2 - 1/2
I/O : Rp1/2" female (ISO 7/1)
Recommended position : horizontal flow, coil on top
of the valve
Application Natural gas supply for one speed SX or KOMFORT heaters.

Installation : see (4.6.2.3)

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.36- GAS SUPPLY KIT G20/25 2 SPEED (RS AME 2 EG)

Natural gas supply kit

COMPOSITION OF KIT

B
A

C
CONTENTS OF
CONNECTOR BAG

2X

Gas Natural gas G20 and G25


Pressures : - inlet 20 mbar mini, 100 mbar maxi
- outlet Ajustable from 12.5 to 30 mbar
Fittings : - inlet Rp 1/2" female (ISO 7/1) (valve inlet)
- outlet Rp 1/2" female (ISO 7/1) (solenoid valve outlets)
Power supply 230V / 50Hz
Capacity 2 x 10 W
Composition (A) : Rp1/2 DN15 VALVE 1/4 turn gas ball-valve
I/O : Rp1/2" female (ISO 7/1)
(B) : REG 1/2F I 20-100 O 12.5-30 MBAR
I/O : Rp1/2" female (ISO 7/1)
Recommended position : horizontal flow
(C) : 2 SOL. VALVE NC 2WAY 1/2 - 1/2
I/O : Rp1/2" female (ISO 7/1)
Recommended position : horizontal flow, coil on top
of the valve
Application Natural gas supply for two speed SX or KOMFORT heaters.

Installation : see (4.6.2.4) (4.6.2.5) (4.6.2.6) (4.6.2.7)

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.37- REG 1/2F I20-100 O12-30 MBAR

Governor for natural gas and propane.

Gas G20 (Natural gas type H) - G25 (Natural gas type L) - G31 (Propane)
Pressures : - inlet 20 mbar min, 100 mbar max
- outlet Adjustable from 12.5 to 30 mbar
Fittings : - inlet Rp 1/2" female (ISO 7/1)
- outlet Rp 1/2" female (ISO 7/1)
Recommended position Horizontal flow
Application Natural gas supply for SX or KOMFORT heaters.

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.38- KOMBI KIT G20/G25 2 SPEED (RS AME 2/B EG)

Natural gas supply kit


This kit is an alternative to the RS AME 2 EG (see 3.3.1.36)

COMPOSITION OF KIT

Gas Natural gas G20 and G25


Pressures : - inlet 20 mbar mini, 100 mbar maxi
- outlet Adjustable from 10 to 30 mbar
Fittings : - inlet Rp 1/2" female (ISO 7/1) (valve inlet)
- outlet Rp 1/2" female (ISO 7/1) (block outlets)
Power supply 230V / 50Hz
Composition (A) : Rp1/2 DN15 VALVE 1/4 turn gas ball-valve
I/O : Rp1/2" female (ISO 7/1)
(B) : block composed of a pressure regulator 10 to 30 mbar
outlet and 2 normally closed (NC) solenoid valves
with built-in inlet filter.
Each of the 2 coils is fitted with a moulded cable
3 x 0.75mm2, length 1 m.
I/O : Rp1/2" female (ISO 7/1)
Recommended position : horizontal flow, coils on top
of the valves
Application Natural gas supply for two speed SX or KOMFORT heaters.

Installation : see (4.6.2.4) (4.6.2.6)

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.39- GAS SUPPLY KIT PROPANE 1 SPEED (RS PR Rp1/2)

Propane supply kit

COMPOSITION OF KIT

B
CONTENTS OF
CONNECTOR BAG

Gas Propane G31


Pressure 50 mbar
Fittings : - inlet Rp 1/2" female (ISO 7/1) (valve inlet)
- outlet Rp 1/2" female (ISO 7/1) (solenoid valve outlet)
Power supply 230V / 50Hz
Capacity 10 W
Composition (A) : Rp1/2 DN15 VALVE 1/4 turn gas ball-valve
I/O : Rp1/2" female (ISO 7/1)
(C) : SOL. VALVE NC 2WAY 1/2 - 1/2
I/O : Rp1/2" female (ISO 7/1)
Recommended position : horizontal flow, coil on top
of the valve
Application Propane supply for one speed SX or KOMFORT heaters

Installation : see (4.6.2.3)

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.40- GAS SUPPLY KIT PROPANE 2 SPEED (RS 2 PR Rp1/2)

Propane supply kit

COMPOSITION OF KIT

B
CONTENTS OF
CONNECTOR BAG

2X

Gas Propane G31


Pressure 50 mbar
Fittings : - inlet Rp1/2" female (ISO 7/1) (valve inlet)
- outlet Rp1/2" female (ISO 7/1) (solenoid valve oulets)
Power supply 230V / 50Hz
Capacity 2 x 10 W
Composition (A) : BALL-VALVE 1/2F- 1/2F 1/4 turn
I/O : Rp1/2" female (ISO 7/1)
(B) : 2 SOL. VALVE NC 2WAY 1/2 - 1/2
I/O : Rp1/2" female (ISO 7/1)
Recommended position : horizontal flow, coils on top
of the valves
Application Propane supply for two speed SX or KOMFORT heaters

Installation : see (4.6.2.4) (4.6.2.5) (4.6.2.6) (4.6.2.7)

Other units : see (10.1)


3- SBM CATALOGUE
3.3.1.41- FITTING FOR SOLDERING 12 G1/2

Fitting 2 parts + washer

Composition
B A C 1 fitting for ferrule 12 mm (A)
1 G1/2"nut (ISO 228/1) (B)
1 viton washer (C)

Application Connection of SX, KOMFORT and M heaters

3.3.1.42- FITTING G1/2F - FERRULE 12MM

Fitting G1/2" (ISO 228/1) female - bicone for Ø12 mm tube

A B C
Gas All types
Fittings : - inlet G1/2" female (ISO 228/1)
- outlet Bicone for Ø12 mm tube
Composition (A) : fitting G1/2" female (ISO 228/1)
(B) : ferrule 12 mm
(C) : nut
Application Gas supply for SX, KOMFORT and M heaters

3.3.1.43- 90° ELBOW G1/2F - FERRULE 12MM

Elbow fitting G1/2" female (ISO 228/1) - bicone for Ø12 mm tube

A B C

Gas All types


Fittings : - inlet G1/2" female (ISO 228/1)
- outlet Bicone for Ø12 mm tube
Composition (A) : 90° fitting G1/2" female (ISO 228/1)
(B) : ferrule 12 mm
(C) : nut
Application Gas supply for B 64-2 KOMFORT heater

Autres unités: see


Other units : voir(10.1)
(10.1) Installation : see (4.6.2)
3- SBM CATALOGUE
3.3.2- ELECTRICAL ACCESSORIES

RP3 .................................................... 3.3.2.1

RP32 .................................................. 3.3.2.2

10 FUS. 5x20 0.25A FAST ACTING .. 3.3.2.3

ROLL SENSOR CABLE 20M ............ 3.3.2.4

ROLL SENSOR CABLE 60M ............ 3.3.2.4

ROLL SENSOR CABLE 300M .......... 3.3.2.4

SWITCH B132 .................................... 3.3.2.5


3- SBM CATALOGUE

PUSH-BUTTON B101 ........................ 3.3.2.6

MANUAL STARTING K2 ................... 3.3.2.7

(Single speed)

MANUAL CONTROL - 1 ZONE ........3.3.2.8


MANUAL CONTROL - 2 ZONES ......3.3.2.8

MANUAL CONTROL - 3 ZONES ......3.3.2.8

MANUAL CONTROL - 4 ZONES ......3.3.2.8

MANUAL CONTROL - 5 ZONES ......3.3.2.8

MANUAL CONTROL - 6 ZONES ......3.3.2.8

ST1 ..................................................... 3.3.2.9

ST1 FIXED SETTING ....................... 3.3.2.10


3- SBM CATALOGUE
Related sections :

Ceramic heaters..........................................................................3.1
Control module ...........................................................................3.2
Installation......................................................................................4
Operation........................................................................................5
Maintenance ...................................................................................6
Trouble-shooting ...........................................................................7
Spare parts.....................................................................................8
Applications ...................................................................................9
3- SBM CATALOGUE
3.3.2.1- RP3

Electrical junction box with individual fuse protection for automatic single speed heaters.

CONTENTS

Power 230V (+10%, -15%) - 50/60Hz


1 individual fuse Size : Ø5 x 20mm
(not included) Capacity : 0.25A
Watertightness IP55
Application Electrical connection of SX heaters.
see (4.7.6.1)

3.3.2.2- RP32

Electrical junction box with individual fuse protection for automatic double speed heaters.

CONTENTS

Power 230V (+10%, -15%) - 50/60Hz


2 individual fuses Size : Ø5 x 20mm
(not included) Capacity : 0.25A
Watertightness IP55
Application Electrical connection of SX and KOMFORT heaters.
see (4.7.6.1)

Other units : see (10.1)


3- SBM CATALOGUE
3.3.2.3- 10 FUS. 5x20 0.25A FAST ACTING

Box of 10 fuses for RP3 and RP32.

Size Ø5 x 20mm
Capacity 0.25A
Application Electrical protection of SX and KOMFORT heaters.
see (4.7.6.1)

3.3.2.4- ROLL SENSOR CABLE xxxM

Electrical shielded cable. (specific quality control by SBM)

CONTENTS

Outside diameter 3.8 mm


Outside casing Blue PVC
Packaging Supplied in roll of 20m, 60m or 300m
Application Connection controle module - sensor
Connection controle module - push-button OVERRIDE
Connection controle module - safety switch

Other units : see (10.1)


3- SBM CATALOGUE
3.3.2.5- SWITCH B132

On / Off switch.

CONTENTS

Function Single-pole switch


Power 230V (+10%, -15%) - 50/60Hz
Maximum capacity 10 A
Watertightness IP65
Application Manual opening / closing of solenoid valves

3.3.2.6- PUSH-BUTTON B101

Push button ‘’On’’ switch.

CONTENT

Function Single-pole push-button


Power 230V (+10%, -15%) - 50/60Hz
Maximum capacity 10 A
Watertightness IP65
Application Manual ignition of SX heaters (maximum 100 BA blocks)

Other units : see (10.1)


3- SBM CATALOGUE
3.3.2.7- MANUAL STARTING K2 (Single speed)

Unit combining On / Off switch and push-button On switch.

CONTENTS

Functions Single-pole switch


(1 NC opening contact + 1 NO closing contact)
Single-pole push button
(1 NC opening contact + 1 NO closing contact)
Power 230V (+10%, -15%) - 50/60Hz
Maximum capacity 3A
Watertightness IP66
Dimensions (W x d x h) 124 mm x 79 mm x 58 mm
Application Manual command for SX or KOMFORT heaters.
On/off switch : control of solenoid valves
Push button : heaters ignition

N L

OFF ON

NO NC NO NC

Solenoid valves RP3

Other units : see (10.1)


3- SBM CATALOGUE
3.3.2.8- MANUAL CONTROL - X ZONE(s)

A B C D
A
Product Box - 4 modules
Watertightness IP 55
Mechanical impacts IK 08
Protection Class II
Accessories 1 terminal for ground wire
(2x16 mm² + 4x10 mm²)
1 terminal for neutral wire
(2x16 mm² + 4x10 mm²)
Dimensions Width : 138 mm x Height : 205 mm x Depth : 109 mm

B
Product Box - 8 modules
Watertightness IP 55
Mechanical impacts IK 08
Protection Class II
Accessories 1 terminal for ground wire
(2x16 mm² + 8x10 mm²)
1 terminal for neutral wire
(2x16 mm² + 8x10 mm²)
Dimensions Width : 225 mm x Height : 205 mm x Depth : 110 mm

C
Product Push-button
Capacity 16 A / 240 VAC

D
Product Circuit breaker
Capacity L1/N 10 A

Product Composed of
MANUAL CONTROL - 1 ZONE A+C+D
MANUAL CONTROL - 2 ZONES A+C+2xD
MANUAL CONTROL - 3 ZONES A+C+3xD
MANUAL CONTROL - 4 ZONES B+C+4xD
MANUAL CONTROL - 5 ZONES B+C+5xD
MANUAL CONTROL - 6 ZONES B+C+6xD
Application Manual control for SX or KOMFORT heaters
Circuit breaker(s) : control of solenoid valves
Push-button : heaters ignition
3- SBM CATALOGUE
3.3.2.9- ST1
Thermostat.

CONTENTS

Function Temperature controle with change-over contact


Temperature can be set from the outside
Cut-off power 230V (+10%, -15%) - 50/60Hz, 16A (cosφ = 1), 3A (cosφ = 0,6)
Setting range 0°C to 50°C
Watertightness IP54
Dimensions (w x d x h) 105 mm x 94 mm x 84 mm
Application Temperature control of SX or KOMFORT heaters
without control module

N L

θ>

2 3

- Solenoid valves
- RP3 via 45" timer

This thermostat must imperatively be combined with a 45 second


timer for ignition of heaters

Other units : see (10.1)


3- SBM CATALOGUE
3.3.2.10- ST1 FIXED SETTING

Thermostat.

CONTENTS

Function Temperature controle with change-over contac


Temperature can be set after removing the closing screw.
Cut-off power 230V (+10%, -15%) - 50/60Hz, 16A (cosφ = 1), 3A (cosφ = 0,6)
Setting range 0°C to 50°C
Watertightness IP54
Dimensions (W x d x h) 105 mm x 94 mm x 84 mm
Application Temperature control of SX or KOMFORT heaters
without control module

N L

θ>

2 3

- Solenoid valves
- RP3 via 45" timer

This thermostat must imperatively be combined with a 45 second


timer for ignition of heaters

Other units : see (10.1)


3- SBM CATALOGUE
3.3.3- PROTECTION AND FIXTURE ACCESSORIES

PROTECTIVE GRILLE B16SX .........3.3.3.1


PROTECTIVE GRILLE B20SX .........3.3.3.2
PROTECTIVE GRILLE B24SX .........3.3.3.3
PROTECTIVE GRILLE B32SX .........3.3.3.4
PROTECTIVE GRILLE B48SX .........3.3.3.5
PROTECTIVE GRILLE B64SX .........3.3.3.6

PROTECTIVE GRILLE B16K ...........3.3.3.7


PROTECTIVE GRILLE B20K ...........3.3.3.8
PROTECTIVE GRILLE B32K ...........3.3.3.9

(For KOMFORT heaters)

BRACKET B6-B8-B10 ....................3.3.3.10


BRACKET B12-B16 .......................3.3.3.11
BRACKET B20-B24-B32-B48 .........3.3.3.12

EXTENSION 60CM .........................3.3.3.13

Related sections :

Ceramic heaters..........................................................................3.1
Control modules .........................................................................3.2
Installation......................................................................................4
Operation........................................................................................5
Maintenance ...................................................................................6
Trouble-shooting ...........................................................................7
Spare parts.....................................................................................8
Applications ...................................................................................9
3- SBM CATALOGUE
3.3.3.1- PROTECTIVE GRILLE B16SX

Heater protection grille

CONTENTS

Material Grille made of Ø4 mm steel wire with 50 mm mesh


Application Protection of B16 SX heater against balls and other flying
objects, for use in gyms and sports halls

3.3.3.2- PROTECTIVE GRILLE B20SX

Heater protection grille

CONTENTS

Material Grille made of Ø4 mm steel wire with 50 mm mesh


Application Protection of B20 SX heater against balls and other flying
objects, for use in gyms and sports halls

3.3.3.3- PROTECTIVE GRILLE B24SX

Heater protection grille

CONTENTS

Material Grille made of Ø4 mm steel wire with 50 mm mesh


Application Protection of B24 SX heater against balls and other flying
objects, for use in gyms and sports halls

Installation : see (4.5.2.7)


3- SBM CATALOGUE
3.3.3.4- PROTECTIVE GRILLE B32SX

Heater protection grille

CONTENTS

Material Grille made of Ø4 mm steel wire with 50 mm mesh


Application Protection of B32 SX and B32-2 SX heaters against balls and
other flying objects, for use in gyms and sports halls

3.3.3.5- PROTECTIVE GRILLE B48SX

Heater protection grille

CONTENTS

Material Grille made of Ø4 mm steel wire with 50 mm mesh


Application Protection of B48-2 SX heater against balls and other flying
objects, for use in gyms and sports halls

3.3.3.6- PROTECTIVE GRILLE B64SX

Heater protection grille

CONTENTS

Material Grille made of Ø4 mm steel wire with 50 mm mesh


Application Protection of B64-2 SX heater against balls and other flying
objects, for use in gyms and sports halls

Installation : see (4.5.2.7)


3- SBM CATALOGUE
3.3.3.7- PROTECTIVE GRILLE B16K

Heater protection grille

Material Grille made of Ø3.5 mm steel wire with 45 mm mesh


Application Protection of B16 KOMFORT heater against balls and other
flying objects, for use in gyms and sports halls

3.3.3.8- PROTECTIVE GRILLE B20K

Heater protection grille

Material Grille made of Ø3.5 mm steel wire with 45 mm mesh


Application Protection of B20 KOMFORT heater against balls and other
flying objects, for use in gyms and sports halls

3.3.3.9- PROTECTIVE GRILLE B32K

Heater protection grille

Material Grille made of Ø3.5 mm steel wire with 45 mm mesh


Application Protection of B32 KOMFORT, B32-2 KOMFORT and B64-2
KOMFORT heaters against balls and other flying objects,
for use in gyms and sports halls.
Use 2 grilles for the B64-2 KOMFORT.
3- SBM CATALOGUE
3.3.3.10- BRACKET B6-B8-B10

Heater multi-directional bracket

COMPOSITION

Material Stainless steel 2 mm


Application Fixing and adjusting the inclination of B6, B8 and B10 SX or
KOMFORT heaters

3.3.3.11- BRACKET B12-B16

Heater multi-directional bracket

COMPOSITION

Material Stainless steel 2 mm


Application Fixing and adjusting the inclination of B12 and B16 SX or
KOMFORT heaters

Installation : see (4.5.2.4)


3- SBM CATALOGUE
3.3.3.12- BRACKET B20-B24-B32-B48
Heater multi-directional bracket

COMPOSITION

Material Stainless steel 2 mm


Application Fixing and adjusting the inclination of B20, B24, B24-2, B32,
B32-2, B48-2 SX or KOMFORT heaters.

3.3.3.13- EXTENSION 60CM


Extension for heater brackets

COMPOSITION

Material Stainless steel 2 mm or aluminium 3 mm


Function Enables the distance between the wall and the heater to be
increased by 0.6 m.
Application Can be used with all multi-directional brackets for SX or
KOMFORT heaters

Wall mounting

0.6 m

Fixing and adjusting


the heater inclination

Installation : see (4.5.2.4)


CERAMIC
HEATING

INSTALLATION 4

4.1- RULES AND REGULATIONS

4.2- TYPES OF INSTALLATION WITH SX OR KOMFORT HEATERS

4.3- TYPES OF INSTALLATION WITH M HEATERS

4.4- SELECTION OF CONTROL MODULE

4.5- INSTALLATION OF HEATERS

4.6- GAS PIPING

4.7- ELECTRICAL WIRING

4.8- FIRST START UP (BY THE INSTALLER)

4.9- RECEIPT OF INSTALLATION

- Return to SUMMARY -
4- INSTALLATION
4.1- RULES AND REGULATIONS

4.1.1- HEATERS

ª SX and M heaters are marked


They are also distributed outside the European Union (see 1.3)

ª KOMFORT heaters are marked for Germany.

ª These heaters must be installed in accordance with applicable regulations, by a


qualified installer.

ª Not intended for domestic application.

4.1.2- GAS PIPING

ª The installation must be carried out by a certified professional.

ª Piping must be installed in accordance with applicable regulations.

4.1.3- ELECTRICAL WIRING

ª The installation must be carried out by a certified professional.

ª The installation must include all necessary protective and safety measures.

ª The installation must be properly grounded.

ª The MT and MTH control modules must be installed in protective casing.

ª The installation must be carried out in accordance with applicable regulations.

4.1.4- VENTILATION

ª The building ventilation must be in accordance with the


European Standard EN 13410.

ª In countries where this standard does not apply, premises need ventilation
of 10m3/h per kW of operating heat input.

4.1.5- APPLICABLE RULES AND REGULATIONS

ª For all information concerning the rules and regulations applicable in your country,
please contact your local SBM agent.
4- INSTALLATION
4.2- TYPES OF INSTALLATION WITH SX OR KOMFORT HEATERS

Diagram Type of installation See

1
- Single speed control with single speed heaters.
- Distribution pressure (PG) > inlet pressure to heaters (p). 4.2.1
- One main solenoid valve.

2
- Single speed control with single speed heaters.
- Distribution pressure (PG) = inlet pressure to heaters (p). 4.2.2
- One main solenoid valve.

3
- Double speed control with double speed heaters.
- Distribution pressure (PG) > inlet pressure to heaters (p). 4.2.3
- One main solenoid valve.

4
- Double speed control with double speed heaters.
- Distribution pressure (PG) = inlet pressure to heaters (p). 4.2.4
- One main solenoid valve.

5
- Double speed control with single speed heaters.
- Distribution pressure (PG) > inlet pressure to heaters (p). 4.2.5
- One main solenoid valve.

6
- Double speed control with single speed heaters.
- Distribution pressure (PG) = inlet pressure to heaters (p). 4.2.6
- One main solenoid valve.

7
- Control of two zones with one single module.
- Distribution pressure (PG) > inlet pressure to heaters (p). 4.2.7
- One main solenoid valve and one solenoid valve for zone 2.

8
- Control of two zones with one single module.
- Distribution pressure (PG) = inlet pressure to heaters (p). 4.2.8
- One main solenoid valve and one solenoid valve for zone 2.

9
- Control of several zones with one single module.
- Distribution pressure (PG) > inlet pressure to heaters (p). 4.2.9
- One solenoid valve per zone.

10
- Control of several zones with one single module.
- Distribution pressure (PG) = inlet pressure to heaters (p). 4.2.10
- One solenoid valve per zone.

NOTE :

Distribution pressure (PG) : available pressure to the main valve (G point).

Inlet pressure (p) : available pressure to the gas inlet connection of heater (see 4.8.1.4).

Injection pressure : pressure measured at the test point of heater (see 4.8.1.4).
4- INSTALLATION

Diagram Type of installation See

11
- One heater without control module.
- Distribution pressure (PG) > inlet pressure to heaters (p). 4.2.11
- No solenoid valve.

12
- One heater without control module.
- Distribution pressure (PG) = inlet pressure to heaters (p). 4.2.12
- No solenoid valve.

13
- No control module.
- Distribution pressure (PG) > inlet pressure to heaters (p). 4.2.13
- One main solenoid valve.

14
- No control module.
- Distribution pressure (PG) = inlet pressure to heaters (p). 4.2.14
- One main solenoid valve.

15
- Control of several zones with one single module.
- Distribution pressure (PG) > inlet pressure to heaters (p). 4.2.15
- One main solenoid valve.

16
- Control of several zones with one single module.
- Distribution pressure (PG) = inlet pressure to heaters (p). 4.2.16
- One main solenoid valve.

17
- Single speed control with single speed heaters.
- Distribution pressure (PG) > inlet pressure to heaters (p). 4.2.17
- One solenoid valve per heater.

18
- Single speed control with single speed heaters.
- Distribution pressure (PG) = inlet pressure to heaters (p). 4.2.18
- One solenoid valve per heater.

19
- Double speed control with double speed heaters.
- Distribution pressure (PG) > inlet pressure to heaters (p). 4.2.19
- Two solenoid valves per heater.

20
- Double speed control with double speed heaters.
- Distribution pressure (PG) = inlet pressure to heaters (p). 4.2.20
- Two solenoid valves per heater.

NOTE :

Distribution pressure (PG) : available pressure to the main valve (G point).

Inlet pressure (p) : available pressure to the gas inlet connection of heater (see 4.8.1.4).

Injection pressure : pressure measured at the test point of heater (see 4.8.1.4).
4- INSTALLATION
4.2.1- DIAGRAM 1
4.2.1.1- TYPE OF INSTALLATION

- Single speed control with single speed heaters


- Distribution pressure (PG) > inlet pressure to heaters (p)
(Individual gas connection assembly must include a fixed regulator or governor)
- One main solenoid valve

RP3

Ceramic heater
Gas connection
assembly

Valve

Filter
Sensor cable
(to be ordered separately)
Solenoid valve

Main valve Sensor


(not supplied (supplied with control module) Fixed regulator/governor
by SBM)
Control unit
Flexible hose
PG

Thermal fuse
230V ~ Gas piping
(L + N + E)
Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP3 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.1.2- OPERATION

Single speed heaters operating at 0% (off) or 100% (heating) are controlled


automatically by the MT100 or MTH100 control modules.
Note : B48-2 and B64-2 heaters can operate on single speed by connecting
both ignitions blocks to one RP32 box.
(see 4.7.6.4)
4- INSTALLATION
4.2.2- DIAGRAM 2
4.2.2.1- TYPE OF INSTALLATION

- Single speed control with single speed heaters


- Distribution pressure (PG) = inlet pressure to heaters (p)
- One main solenoid valve

RP3

Ceramic heater
Gas connection
assembly

Valve

Filter
Sensor cable
(to be ordered separately)
Solenoid valve

Main valve Sensor


(not supplied (supplied with control module) Fixed regulator/governor
by SBM)
Control unit
Flexible hose
PG

Thermal fuse
230V ~ Gas piping
(L + N + E)
Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP3 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.2.2- OPERATION

Single speed heaters operating at 0% (off) or 100% (heating) are controlled


automatically by the MT100 or MTH100 control modules.
Note : B48-2 and B64-2 heaters can operate on single speed by connecting
both ignitions blocks to one RP32 box.
(see 4.7.6.4)
4- INSTALLATION
4.2.3- DIAGRAM 3
4.2.3.1- TYPE OF INSTALLATION

- Double speed control with double speed heaters


- Distribution pressure (PG) > inlet pressure to heaters (p)
(Individual gas connection assembly must include a fixed regulator or governor)
- One main solenoid valve

RP32

2 speed
Gas connection ceramic heater
assembly

Valve

Filter
Sensor cable
(to be ordered separately)
Solenoid valve

Sensor
Main valve (supplied with control module)
(not supplied Fixed regulator/governor
by SBM) Control unit
PG Flexible hose

Thermal fuse
230V ~
(L + N + E) Gas piping
Electric wiring
Sensor cable
- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP32 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.3.2- OPERATION

Double speed heaters operating at 0% (off), 50% (half the burners) or 100%
(all burners) are controlled automatically by the MT150 or MTH150 control
modules.
4- INSTALLATION
4.2.4- DIAGRAM 4
4.2.4.1- TYPE OF INSTALLATION

- Double speed control with double speed heaters


- Distribution pressure (PG) = inlet pressure to heaters (p)
- One main solenoid valve

RP32

2 speed
Gas connection ceramic heater
assembly

Valve

Filter
Sensor cable
(to be ordered separately)
Solenoid valve

Sensor
Main valve
(supplied with control module)
(not supplied Fixed regulator/governor
by SBM) Control unit
PG Flexible hose

Thermal fuse
230V ~
(L + N + E)
Gas piping
Electric wiring
Sensor cable
- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP32 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.4.2- OPERATION

Double speed heaters operating at 0% (off), 50% (half the burners) or 100%
(all burners) are controlled automatically by the MT150 or MTH150 control
modules.
4- INSTALLATION
4.2.5- DIAGRAM 5
4.2.5.1- TYPE OF INSTALLATION

- Double speed control with single speed heaters


- Distribution pressure (PG) > inlet pressure to heaters (p)
(Individual gas connection assembly must include a fixed regulator or governor)
- One main solenoid valve

RP3 50% Line


100% Line

Ceramic heater
Gas connection
assembly

Valve

Filter
Sensor cable
(to be ordered separately)
Solenoid valve

Sensor
Main valve (supplied with control module)
Fixed regulator/governor
(not supplied
by SBM) Control unit
Flexible hose
PG
Thermal fuse
230V ~ Gas piping
(L + N + E) Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP3 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.5.2- OPERATION

Instead of using double speed heaters, single speed heaters operating at 0%


(off) or 100% (heating) are used, divided in two lines (50%, 100%), and
controlled automatically by the MT150 or MTH150 control module.
Operation at 50% is then achieved by lighting 1 every 2 heaters instead of 1
every 2 burners. (see 4.2.3)
4- INSTALLATION
4.2.6- DIAGRAM 6
4.2.6.1- TYPE OF INSTALLATION

- Double speed control with single speed heaters


- Distribution pressure (PG) = inlet pressure to heaters (p)
- One main solenoid valve

RP3 50% line


100% line

Ceramic heater
Gas connection
assembly

Valve

Filter
Sensor cable
(to be ordered separately)
Solenoid valve

Sensor
Main valve (supplied with control module) Fixed regulator/governor
(not supplied
by SBM)
Control unit
Flexible hose
PG
Thermal fuse
230V ~ Gas piping
(L + N + E) Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP3 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.6.2- OPERATION

Instead of using double speed heaters, single speed heaters operating at 0%


(off) or 100% (heating) are used, divided in two lines (50%, 100%), and
controlled automatically by the MT150 or MTH150 control module.
Operation at 50% is then achieved by lighting 1 every 2 heaters instead of 1
every 2 burners. (see 4.2.4)
4- INSTALLATION
4.2.7- DIAGRAM 7
4.2.7.1- TYPE OF INSTALLATION

- Control of two zones with one single control module


- Distribution pressure (PG) > inlet pressure to heaters (p)
(Individual gas connection assembly must include a fixed regulator or governor)
- One main solenoid valve and one solenoid valve for zone 2

Main solenoid valve Solenoid valve zone 2

RP3

Ceramic heater
Gas connection
assembly

Valve

Filter
Sensor cable
(to be ordered separately)
Solenoid valve
Zone 2 switch

Main valve Sensor Fixed regulator/governor


(not supplied (supplied with control module)
by SBM) Control unit
Flexible hose
PG
230V ~ Thermal fuse
(L + N + E) Gas piping
Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP3 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.7.2- OPERATION

This type of installation allows for the control of two independent zones using
only one module. When lighting the heaters, one can choose whether or not to
heat zone 2 by turning on or off the zone 2 switch (zone 1 is always heated).
The sensor must be placed in zone 1.
This arrangement is recommended for small installations.
4- INSTALLATION
4.2.8- DIAGRAM 8
4.2.8.1- TYPE OF INSTALLATION

- Control of two zones with one single control module


- Distribution pressure (PG) = inlet pressure to heaters (p)
- One main solenoid valve and one solenoid valve for zone 2

Main solenoid valve Solenoid valve zone 2

RP3

Ceramic heater
Gas connection
assembly

Valve

Filter
Sensor cable
(to be ordered separately)

Zone 2 switch Solenoid valve

Sensor
Main valve
(not supplied
(supplied with control module) Fixed regulator/governor
by SBM)
Control unit
Flexible hose
PG

Thermal fuse
230V ~ Gas piping
(L + N + E) Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP3 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.8.2- OPERATION

This type of installation allows for the control of two independent zones using
only one module. When lighting the heaters, one can choose whether or not
to heat zone 2 by turning on or off the zone 2 switch (zone 1 is always heated).
The sensor must be placed in zone 1.
This arrangement is recommended for small installations.
4- INSTALLATION
4.2.9- DIAGRAM 9
4.2.9.1- TYPE OF INSTALLATION

- Control of several zones with one single control module


- Distribution pressure (PG) > inlet pressure to heaters (p)
(Individual gas connection assembly must include a fixed regulator or governor)
- One solenoid valve per zone

Solenoid valve zone 1

RP3

Ceramic heater
Gas connection
assembly
Valve

Filter
Zone switches
Sensor cable
(to be ordered separately) Solenoid valve

Main valve Sensor


Fixed regulator/governor
(not supplied (supplied with control module)
by SBM)
Control unit Flexible hose
PG
Thermal fuse

230V ~ Gas piping


(L + N + E) Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP3 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.9.2- OPERATION

This type of installation allows for the control of several zones using only one
module. When lighting the heaters, one can choose the zones to be heated,
by turning on the appropriate zone switches. If zone 1 is not chosen, there will
be no control of the heating (sensor placed in zone 1).
This arrangement is recommended for small installations.
4- INSTALLATION
4.2.10- DIAGRAM 10
4.2.10.1- TYPE OF INSTALLATION

- Control of several zones with one single control module


- Distribution pressure (PG) = inlet pressure to heaters (p)
- One solenoid valve per zone

Solenoid valve zone 1

RP3

Ceramic heater
Gas connection
assembly
Valve
Zone switches Filter
Sensor cable
(to be ordered separately)
Solenoid valve

Sensor
Main valve
(supplied with control module) Fixed regulator/governor
(not supplied
by SBM)
Control unit
Flexible hose
PG

Thermal fuse
230V ~ Gas piping
(L + N + E)
Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP3 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.10.2- OPERATION

This type of installation allows for the control of several zones using only one
module. When lighting the heaters, one can choose the zones to be heated,
by turning on the appropriate zone switches. If zone 1 is not chosen, there will
be no control of the heating (sensor placed in zone 1).
This arrangement is recommended for small installations.
4- INSTALLATION
4.2.11- DIAGRAM 11
4.2.11.1- TYPE OF INSTALLATION

- One heater without control module


- Distribution pressure (PG) > inlet pressure to heaters (p)
(Individual gas connection assembly must include a fixed regulator or governor)
- No solenoid valve

RP3

Ceramic heater

Gas connection
assembly
Valve

Filter

Solenoid valve

Fixed regulator/governor

Push button ignition


Valve
Flexible hose

PG
230V ~ Thermal fuse
(L + N + E) Gas piping
Electric wiring
Sensor cable

- The valve must be selected in relation to the gas pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of fuse capacity to be installed in the RP3 box : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.11.2- OPERATION

This type of installation enables a heater to be operated manually without


control module.
Ignition is carried out by opening the valve then pressing on the push button
during 45 seconds. The heater is turned off by closing the valve.
There is no temperature control.
4- INSTALLATION
4.2.12- DIAGRAM 12
4.2.12.1- TYPE OF INSTALLATION

- One heater without control module


- Distribution pressure (PG) = inlet pressure to heaters (p)
- No solenoid valve

RP3

Ceramic heater

Gas connection
assembly
Valve

Filter

Solenoid valve

Fixed regulator/governor

Push button ignition


Flexible hose
Valve
PG
230V ~ Thermal fuse
(L + N + E) Gas piping
Electric wiring
Sensor cable

- The valve must be selected in relation to the gas pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of fuse capacity to be installed in the RP3 box : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.12.2- OPERATION

This type of installation enables a heater to be operated manually without


control module.
Ignition is carried out by opening the valve then pressing on the push button
during 45 seconds. The heater is turned off by closing the valve.
There is no temperature control.
4- INSTALLATION
4.2.13- DIAGRAM 13
4.2.13.1- TYPE OF INSTALLATION

- No control module
- Distribution pressure (PG) > inlet pressure to heaters (p)
(Individual gas connection assembly must include a fixed regulator or governor)
- One main solenoid valve

RP3

Ceramic heater
Gas connection
assembly

Valve

Filter

Solenoid valve

Solenoid valve switch


Main valve
(not supplied
Fixed regulator/governor
Push button ignition
by SBM)
Flexible hose
PG

Thermal fuse
230V ~ Gas piping
(L + N + E) Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP3 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.13.2- OPERATION

This type of installation enables several heaters to be operated without control


module. Ignition is carried out by turning on the solenoid valve switch, then
pressing on the push button ignition during 45 seconds.
The heaters are turned off by turning the solenoid valve switch to ‘’Off’’.
There is no temperature control.
4- INSTALLATION
4.2.14- DIAGRAM 14
4.2.14.1- TYPE OF INSTALLATION

- No control module
- Distribution pressure (PG) = inlet pressure to heaters (p)
- One main solenoid valve

RP3

Ceramic heater
Gas connection
assembly

Valve

Filter

Solenoid valve

Solenoid valve switch


Main valve
Fixed regulator/governor
(not supplied Push button ignition
by SBM)
Flexible hose
PG
Thermal fuse
230V ~ Gas piping
(L + N + E) Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP3 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.14.2- OPERATION

This type of installation enables several heaters to be operated without control


module. Ignition is carried out by turning on the solenoid valve switch, then
pressing on the push button ignition during 45 seconds.
The heaters are turned off by turning the solenoid valve switch to ‘’Off’’.
There is no temperature control.
4- INSTALLATION
4.2.15- DIAGRAM 15
4.2.15.1- TYPE OF INSTALLATION

- Control of several zones with one single control module


- Distribution pressure (PG) > inlet pressure to heaters (p)
(Individual gas connection assembly must include a fixed regulator or governor)
- One main solenoid valve

RP3

Ceramic heater
Gas connection
assembly

Valve
Zone switches Filter
Sensor cable
(to be ordered separately)
Solenoid valve

Main valve Sensor


(not supplied (supplied with control module) Fixed regulator/governor
by SBM)
Control unit
Flexible hose
PG

Thermal fuse
230V ~ Gas piping
(L + N + E)
Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP3 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.15.2- OPERATION

This type of installation (alternative to 4.2.9) allows for the control of several
zones using only one module. When lighting the heaters, one can choose the
zones to be heated, by turning on the appropriate zone switches.
If zone 1 is not chosen, there will be no control of the temperature
(sensor placed in zone 1).
This arrangement is recommended for small installations.
4- INSTALLATION
4.2.16- DIAGRAM 16
4.2.16.1- TYPE OF INSTALLATION

- Control of several zones with one single control module


- Distribution pressure (PG) = inlet pressure to heaters (p)
- One main solenoid valve

RP3

Ceramic heater
Gas connection
assembly

Valve
Zone switches
Filter
Sensor cable
(to be ordered separately)
Solenoid valve

Sensor
Main valve
(supplied with control module) Fixed regulator/governor
(not supplied
by SBM)
Control unit
Flexible hose
PG

Thermal fuse
230V ~ Gas piping
(Ph + N + T)
Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP3 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.16.2- OPERATION

This type of installation (alternative to 4.2.10) allows for the control of several
zones using only one module. When lighting the heaters, one can choose the
zones to be heated, by turning on the appropriate zone switches.
If zone 1 is not chosen, there will be no control of the temperature
(sensor placed in zone 1).
This arrangement is recommended for small installations.
4- INSTALLATION
4.2.17- DIAGRAM 17
4.2.17.1- TYPE OF INSTALLATION

- Single speed control with single speed heaters


- Distribution pressure (PG) > inlet pressure to heaters (p)
(Individual gas connection assembly must include a fixed regulator or governor)
- One solenoid valve per heater

RP32

Ceramic heater
Gas connection
assembly

Valve

Sensor cable Filter


(to be ordered separately)

Solenoid valve
Sensor
Main valve (supplied with control module)
(not supplied
by SBM) Control unit Fixed regulator/governor

PG Flexible hose

230V ~ Thermal fuse


(L + N + E) Gas piping
Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP32 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.17.2- OPERATION

Single speed heaters operating at 0% (off) or 100% (heating) are controlled


automatically by the MT100 DE or MTH100 DE control modules.
NOTE : B48-2 and B64-2 heaters can operate on single speed (see 4.7.6.4).
4- INSTALLATION
4.2.18- DIAGRAM 18
4.2.18.1- TYPE OF INSTALLATION

- Single speed control with single speed heaters


- Distribution pressure (PG) = inlet pressure to heaters (p)
- One solenoid valve per heater

RP32

Ceramic heater
Gas connection
assembly
Valve

Filter
Sensor cable
(to be ordered separately)
Solenoid valve
Sensor
Main valve (supplied with control module)
(not supplied Fixed regulator/governor
by SBM) Control unit
PG Flexible hose

Thermal fuse
230V ~
(L + N + E) Gas piping
Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP32 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

All gas accessories must comply with the distribution pressure (PG)

4.2.18.2- OPERATION

Single speed heaters operating at 0% (off) or 100% (heating) are controlled


automatically by the MT100 DE or MTH100 DE control modules.
NOTE : B48-2 and B64-2 heaters can operate on single speed (see 4.7.6.4).
4- INSTALLATION
4.2.19- DIAGRAM 19
4.2.19.1- TYPE OF INSTALLATION

- Double speed control with double speed heaters


- Distribution pressure (PG) > inlet pressure to heaters (p)
(Individual gas connection assembly must include a fixed regulator or governor)
- Two solenoid valves per heater

RP32

2 speed ceramic heater


Gas connection
assembly Sensor cable
(to be ordered separately)

Valve
Main valve
(not supplied Filter
by SBM) Control unit Sensor
(supplied with control
PG module)
Solenoid valve

230V ~
(L + N + E) Fixed regulator/governor

Flexible hose

All gas accessories must Thermal fuse


comply with the distribution Gas piping
pressure (PG) Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP32 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

4.2.19.2- OPERATION

Double speed heaters operating at 0% (off), 50% (half the burners) or 100%
(all burners) are controlled automatically by the MT150 DE or MTH150 DE
control modules.
4- INSTALLATION
4.2.20- DIAGRAM 20
4.2.20.1- TYPE OF INSTALLATION

- Double speed control with double speed heaters


- Distribution pressure (PG) = inlet pressure to heaters (p)
- Two solenoid valves per heater

RP32

2 speed ceramic heater


Gas connection
assembly
Sensor cable
(to be ordered separately)

Main valve Valve


(not supplied
by SBM) Control unit Filter
Sensor
PG (supplied with
control module)
Solenoid valve

230V ~
(L + N + E) Fixed regulator/governor

Flexible hose

All gas accessories must Thermal fuse


comply with the distribution Gas piping
pressure (PG) Electric wiring
Sensor cable

- The main valve, filter and solenoid valve must be selected in relation to the gas
pressure, flow rate and piping diameter.
- Selection of gas connection assembly : see 4.6.2.
- Selection of control module : see 4.4.
- Selection of fuse capacity to be installed in the RP32 boxes : see 4.7.6.
- Selection of electric cables : see 4.7.3.

4.2.20.2- OPERATION

Double speed heaters operating at 0% (off), 50% (half the burners) or 100%
(all burners) are controlled automatically by the MT150 DE or MTH150 DE
control modules.
4- INSTALLATION
4.3- TYPES OF INSTALLATION WITH M HEATERS

4.3.1- DIAGRAM 1
4.3.1.1- TYPE OF INSTALLATION

- Distribution pressure (PG) > inlet pressure to heaters (p)


(Individual gas connection assembly must include a fixed regulator or governor)

M ceramic heater
Gas connection
assembly

Valve

Filter

Fixed regulator/governor

Flexible hose
Valve
PG Gas piping

- The main valve and filter must be selected in relation to the gas pressure, flow rate
and piping diameter.
- Selection of gas connection assembly : see 4.6.2.

All gas accessories must comply with the distribution pressure (PG)

4.3.1.2- OPERATION

M radiant heaters are lit manually, one by one.


They are all turned off at the same time by closing the valve.

To facilitate their ignition, M heaters must be easily accessible.


4- INSTALLATION
4.3.2- DIAGRAM 2
4.3.2.1- TYPE OF INSTALLATION

- Distribution pressure (PG) = inlet pressure to heaters (p)

M ceramic heater
Gas connection
assembly

Valve

Filter

Fixed regulator/governor

Flexible hose
Valve
PG Gas piping

- The main valve and filter must be selected in relation to the gas pressure, flow rate
and piping diameter.
- Selection of gas connection assembly : see 4.6.2.

All gas accessories must comply with the distribution pressure (PG)

4.3.1.2- OPERATION

M radiant heaters are lit manually, one by one.


They are all turned off at the same time by closing the valve.

To facilitate their ignition, M heaters must be easily accessible.


4- INSTALLATION
4.4- SELECTION OF CONTROL MODULE

Select the type of module in relation to the functions needed.

MODULES

FUNCTIONS MT 100 MT 150 MTH 100 MTH 150

Single speed 9 9
Double speed 9 9
Clock /
Programming 9 9

Installations carried out following the diagrams 17 to 20 (4.2.17 to 4.2.20),


require the use of modules MT or MTH type DE.
4- INSTALLATION
4.5- INSTALLATION OF HEATERS

4.5.1- UNPACKING AND CHECKING THE EQUIPMENT

ª Check the type and quantities of equipment against your order.

ª Check that packing and equipment is intact.


In the event of damage, register a complaint to this effect with the carrier.

ª Check gas type and pressure to be used (see heater rating plate).

4.5.2- FIXING OF HEATERS

4.5.2.1- MINIMUM SAFETY HEIGHTS

Type of heater Min. height (m)


B6 3.00
B8 3.10
B10 3.20
B12 3.40
B16 3.60
B20 / B20-2 3.80
B24 / B24-2 4.10
B32 / B32-2 4.50
B48-2 5.00
B64-2 5.50

For comfort heights, see 9.3

4.5.2.2- MINIMUM SAFETY CLEARANCES

This refers to the minimum distances to be respected between a heater


and inflammable materials (Max. temperature: 70°C)

HEATED AREA
1m
0,2m
min.

A
min. (*) 2m
min. 1m min.

HEATED AREA

(*) for a 10° to 20° inclination "I" or slope "S", A=1m.


(*) for a 20° to 35° inclination "I" or slope "S", A=0.6m.

Where safety clearances cannot be respected, heat protection must be provided


(see 4.5.2.6)
4- INSTALLATION
4.5.2.3- EXAMPLES OF MOUNTING BRACKETS TO BE SUPPLIED
BY THE INSTALLER

B6, B8, B10, B12 and B16 type heaters

3/4" steel tube or


25 x 25 square profile

SBM ceramic heater


(3.1)

Valve (3.3.1)

Anchoring plate

Fixed regulator or
governor (3.3.1)

RP3 (except M heaters)


(3.3.2.1) 300

100 Dimensions in mm

B20, B20-2, B24, B24-2, B32 and B32-2 type heaters

3/4" steel tube or


25 x 25 square profile

SBM ceramic heater


(3.1)

Valve (3.3.1)

Anchoring plate

Fixed regulator or
governor (3.3.1)
RP3 (3.3.2.1) (B20, B24 and B32)
RP32 (3.3.2.2) (B20-2, B24-2, 400
B32-2 and B64-2)

Dimensions in mm.
100

To know which references in the SBM catalogue are available in your country, please
consult your current SBM price list.
4- INSTALLATION
B48-2 type heaters

SBM ceramic heater


(3.1)

900

100 min.

3/4" steel tube or Dimensions in mm.


25x25 square profile

Fixed regulator or
governor (3.3.1)

Anchoring plate

RP32 (3.3.2.2)

Valve (3.3.1)

To know which references in the SBM catalogue are available in your country, please
consult your current SBM price list.
4- INSTALLATION
B64-2 type heaters

SBM ceramic heater


(3.1)

900
100 min.

3/4" steel tube or


25x25 square profile
Dimensions in mm.

Fixed regulator or
governor (3.3.1)

Anchoring plate

RP32 (3.3.2.2)

Valve (3.3.1)

To know which references in the SBM catalogue are available in your country, please
consult your current SBM price list.
4- INSTALLATION
4.5.2.4- MULTI-DIRECTIONAL BRACKETS

All types of heater except the B64-2

Bracket
B6, B8 and B10 (3.3.3.11)
B12 and B16 (3.3.3.12)
B20, B20-2, B24, B24-2, B32, B32-2 and
B48-2 (3.3.3.13)

SBM ceramic heater


(3.1)

Extension for multi-directional bracket

Bracket
B6, B8 and B10 (3.3.3.11)
B12 and B16 (3.3.3.12)
B20, B20-2, B24, B24-2, B32, B32-2 and
B48-2 (3.3.3.13)

Extension 60cm
(3.3.3.14)

SBM ceramic heater


(3.1)
4- INSTALLATION
4.5.2.5- INCLINATION OF HEATERS

ª Inclination "I"
S = 0°

I = 10 → 35°
BA block in low position

ª Slope "S"

I = 0°

S = 10 → 35°
BA block in low position

ª The values of "I" and "S" recommended for each installation are indicated
on the SBM survey drawing (if one has been carried out).

In all cases, either the inclination "I" or the slope "S" must be at least 10°.

Always install the automatic ignition block (BA block) in low position.

ª For the B24-2 and B32-2 with inclination


(I = 10 → 35° and S = 0°)

100% 50%
operation operation

Always light the top burner first.


4- INSTALLATION
ª For the B48-2

No Yes

100% 66%
operation operation

ª For the B64-2SX

No Yes
ª For the B64-2 KOMFORT

No Yes
4- INSTALLATION
4.5.2.6- HEAT PROTECTION

ª Protection of materials situated above a radiant heater


(e.g.: wiring, piping, tubing, etc. ...)

Sheet metal deflector held in place


by the heater mounting bracket.

30*

Dimensions in mm.
50 100

100

30*

The sheet metal deflector must not continue above the air inlet (30 mm far).
*
4- INSTALLATION
Sheet metal deflector held in place
by the heater mounting brackets.

30*

Dimensions in mm.

100
30*

100

100

The sheet metal deflector must not continue above the air inlet (30 mm far).
*
4- INSTALLATION
ª Ceiling protection (heater - ceiling distance < 1 m)

Thermal insulation
(example : 10 mm ceramic fibers)

approx. 100

Metal plate

Dimensions in mm.

300 300

300

300
4- INSTALLATION
ª Crane protection (heater - crane distance < 2 m)

Heat protection.

2m
d approx.100 Dimensions in mm.

Protect every heat-sensitive part of the


crane which may be exposed to excessive
heat (less than 2 m from the heater).

If d < 500 mm, contact your SBM agent or


distributor.
4- INSTALLATION
4.5.2.7- MECHANICAL PROTECTION

ª Grilles for protecting SX heaters from balls and other flying objects.

Mounting lugs

Position the grille facing the Clip the grille onto the ridges on
1 frame of the heater.
2 the sides of the frame.

Use a pair of pliers to fold the mounting lugs of the grille towards the inside of the
3
heater and flatten them against the sides of the frame.
4- INSTALLATION
4.6- GAS PIPING
Before installation, check that the local conditions of supply, gas type / pressure
and equipment settings are compatible.

4.6.1- GAS PIPING

ª Gas piping must not produce any stress on the injector block of the
heater : use preferably a flexible metallic hose
(3.3.1.31), (3.3.1.32) and (3.3.1.33)

ª Gas piping must not be installed in the heated area around the heater.
(see diagram below)

HEATED
AREA
1m 0.2m

2m

HEATED AREA
4- INSTALLATION
4.6.2- GAS CONNECTION ASSEMBLIES

4.6.2.1- SINGLE SPEED HEATERS

[Distribution pressure (PG) > inlet pressure to heaters (p)]

D C B A

A Rp1/2 DN15 VALVE 3.3.1.9


B UNION FITTING R1/2m-G1/2m 3.3.1.25
DF64 G1/2 G31-37 4KG/H 3.3.1.5
DF64 G1/2 G20-20 3M3/H 3.3.1.6
C
DF64 G1/2 G25-25 3M3/H 3.3.1.7
DF64 G1/2 G30/31-30 5KG/H 3.3.1.8
METALLIC HOSE G1/2F 700mm 3.3.1.31
D
METALLIC HOSE G1/2F ERP 750mm 3.3.1.32

A + B + C compose the kit : VDF G31-37 Rp1/2-G1/2m (3.3.1.1) or


VDF G20-20 Rp1/2-G1/2m (3.3.1.2) or
VDF G25-25 Rp1/2-G1/2m (3.3.1.3) or
VDF G30/31-30 Rp1/2-G1/2m (3.3.1.4).

[Distribution pressure (PG) = inlet pressure to heaters (p)]

D B A

A Rp1/2 DN15 VALVE 3.3.1.9


B UNION FITTING R1/2m-G1/2m 3.3.1.25
METALLIC HOSE G1/2F 700mm 3.3.1.31
D
METALLIC HOSE G1/2F ERP 750mm 3.3.1.32

Use of the UNION FITTING R1/2m-G1/2m see (10.4).


4- INSTALLATION
4.6.2.2- DOUBLE SPEED HEATERS
[Distribution pressure (PG) > inlet pressure to heaters (p)]

This diagram is not valid for B64-2SX heaters


operating with G25-25 mbar : see following page.

D F F

D E C B A

A Rp1/2 DN15 VALVE 3.3.1.9


B UNION FITTING R1/2m-G1/2m 3.3.1.25
DF64 G1/2 G31-37 4KG/H 3.3.1.5
DF64 G1/2 G20-20 3M3/H 3.3.1.6
C
DF64 G1/2 G25-25 3M3/H 3.3.1.7
DF64 G1/2 G30/31-30 5KG/H 3.3.1.8
METALLIC HOSE G1/2F 700mm 3.3.1.31
D
METALLIC HOSE G1/2F ERP 750mm 3.3.1.32
E SLEEVE F/F G1/2 3.3.1.29
F VITON WASHER G1/2 3.3.1.30
G T FITTING MALE G1/2 3.3.1.28

A + B + C compose the kit : VDF G31-37 Rp1/2-G1/2m (3.3.1.1) or


VDF G20-20 Rp1/2-G1/2m (3.3.1.2) or
VDF G25-25 Rp1/2-G1/2m (3.3.1.3) or
VDF G30/31-30 Rp1/2-G1/2m (3.3.1.4).

Use of the UNION FITTING R1/2m-G1/2m see (10.4).


4- INSTALLATION
ª B64-2SX operating with G25-25.
D F F

Use of the UNION FITTING


R1/2m-G1/2m see (10.4).

E B A

D
A Rp1/2 DN15 VALVE 3.3.1.9
B UNION FITTING R1/2m-G1/2m 3.3.1.25
C DF64 G1/2 G25-25 3M3/H 3.3.1.7
METALLIC HOSE G1/2F 700mm 3.3.1.31
D
METALLIC HOSE G1/2F ERP 750mm 3.3.1.32
E SLEEVE F/F G1/2 3.3.1.29
F VITON WASHER G1/2 3.3.1.30
G T FITTING MALE G1/2 3.3.1.28
[Distribution pressure (PG) = inlet pressure to heaters (p)]

D F F Use of the UNION FITTING


R1/2m-G1/2m see (10.4).

D E B A
A Rp1/2 DN15 VALVE 3.3.1.9
B UNION FITTING R1/2m-G1/2m 3.3.1.25
METALLIC HOSE G1/2F 700mm 3.3.1.31
D
METALLIC HOSE G1/2F ERP 750mm 3.3.1.32
E SLEEVE F/F G1/2 3.3.1.29
F VITON WASHER G1/2 3.3.1.30
G T FITTING MALE G1/2 3.3.1.28
4- INSTALLATION
4.6.2.3- SINGLE SPEED HEATERS WITH INDIVIDUAL SOLENOID VALVE

[Distribution pressure (PG) > inlet pressure to heaters (p)] : NATURAL GAS

I H G F D E D C B A

A THERMAL FUSE 3.3.1.34


B Valve 1/2f - 1/2f
C FLEXIBLE HOSE 500 1/2M 1/2F 3.3.1.33
D Union fitting 1/2" Nr 280 not supplied
E Reg 1/2f i: 20-100, o: 12.5-30 mbar
F Sol. valve NC 2way 1/2 -1/2
G Steel tube 1/2", length 100 mm not supplied
H FITTING G1/2F - FERRULE 12MM 3.3.1.42
I FITTING FOR SOLDERING 12 G1/2 3.3.1.41

B + E + F compose the GAS SUPPLY KIT G20/25 1 SPEED (RS AME EG) (3.3.1.35)

ALTERNATIVE : Possibility of removing C and replacing G, H and I by


Q " METALLIC HOSE G1/2F 700mm " (3.3.1.31)
+ R " UNION FITTING R1/2m-G1/2m " (3.3.1.25)
(see 4.6.2.8 – Example 1)
4- INSTALLATION
[Distribution pressure (PG) = inlet pressure to heaters (p)] : PROPANE

I H G F D C B A

A THERMAL FUSE 3.3.1.34


B Valve 1/2f - 1/2f
C FLEXIBLE HOSE 500 1/2M 1/2F 3.3.1.33
D Union fitting 1/2" Nr 280 not supplied
F Sol. valve NC 2way 1/2 -1/2
G Steel tube 1/2", length 100 mm not supplied
H FITTING G1/2F - FERRULE 12MM 3.3.1.42
I FITTING FOR SOLDERING 12 G1/2 3.3.1.41

B + F compose the GAS SUPPLY KIT PROPANE 1 SPEED (RS PR Rp1/2) (3.3.1.39)

ALTERNATIVE : Possibility of removing C and replacing G, H and I by


Q " METALLIC HOSE G1/2F 700mm " (3.3.1.31)
+ R " UNION FITTING R1/2m-G1/2m " (3.3.1.25)
(see 4.6.2.8 – Example 1)
4- INSTALLATION
4.6.2.4- DOUBLE SPEED HEATERS B20-2, B24-2 AND B32-2, WITH INDIVIDUAL
SOLENOID VALVES
[Distribution pressure (PG) > inlet pressure to heaters (p)] : NATURAL GAS

I H G F D K G

I H G F D J D E D C B A
A THERMAL FUSE 3.3.1.34
B Valve 1/2f - 1/2f
C FLEXIBLE HOSE 500 1/2M 1/2F 3.3.1.33
D Union fitting 1/2" Nr 280 not supplied
E Reg 1/2f i: 20-100, o: 12.5-30 mbar
F Sol. valve NC 2way 1/2 -1/2
G Steel tube 1/2", length 100 mm not supplied
H FITTING G1/2F - FERRULE 12MM 3.3.1.42
I FITTING FOR SOLDERING 12 G1/2 3.3.1.41
J Steel T 1/2" Nr 130 not supplied
K Steel elbow 90° 1/2" Nr 90 not supplied

B + E + F compose the GAS SUPPLY KIT G20/25 2 SPEED (RS AME 2 EG) (3.3.1.36)

ALTERNATIVE : Possibility of removing C and replacing G, H and I by


Q " METALLIC HOSE G1/2F 700mm " (3.3.1.31)
+ R " UNION FITTING R1/2m-G1/2m " (3.3.1.25)
(see 4.6.2.8 – Example 2)
4- INSTALLATION
ª Alternative with KOMBI KIT
I H G

I H G L D C B A
A THERMAL FUSE 3.3.1.34
B Valve 1/2f - 1/2f
C FLEXIBLE HOSE 500 1/2M 1/2F 3.3.1.33
D Union fitting 1/2" Nr 280 not supplied
G Steel tube 1/2", length 100 mm not supplied
H FITTING G1/2F - FERRULE 12MM 3.3.1.42
I FITTING FOR SOLDERING 12 G1/2 3.3.1.41
L Kombiblock 1/2f 2 speed

B + L compose the KOMBI KIT G20/G25 2 SPEED (RS AME 2/B EG) (3.3.1.38)

ALTERNATIVE : Possibility of removing C and replacing G, H and I by


Q " METALLIC HOSE G1/2F 700mm " (3.3.1.31)
+ R " UNION FITTING R1/2m-G1/2m " (3.3.1.25)
(see 4.6.2.8 – Example 2)
4- INSTALLATION
[Distribution pressure (PG) = inlet pressure to heaters (p)] : PROPANE

I H G F D K G

I H G F D J D C B A

A THERMAL FUSE 3.3.1.34


B Valve 1/2f - 1/2f
C FLEXIBLE HOSE 500 1/2M 1/2F 3.3.1.33
D Union fitting 1/2" Nr 280 not supplied
F Sol. valve NC 2way 1/2 -1/2
G Steel tube 1/2", length 100 mm not supplied
H FITTING G1/2F - FERRULE 12MM 3.3.1.42
I FITTING FOR SOLDERING 12 G1/2 3.3.1.41
J Steel T 1/2" Nr 130 not supplied
K Steel elbow 90° 1/2" Nr 90 not supplied

B + F compose the GAS SUPPLY KIT PROPANE 2 SPEED (RS 2 PR Rp1/2) (3.3.1.40)

ALTERNATIVE : Possibility of removing C and replacing G, H and I by


Q " METALLIC HOSE G1/2F 700mm " (3.3.1.31)
+ R " UNION FITTING R1/2m-G1/2m " (3.3.1.25)
(see 4.6.2.8 – Example 2)
4- INSTALLATION
4.6.2.5-DOUBLE SPEED B48-2 KOMFORT HEATERS, WITH INDIVIDUAL
SOLENOID VALVES

[Distribution pressure (PG) > inlet pressure to heaters (p)] : NATURAL GAS

I H G F D K P

I H G F D E D C B

J A

A THERMAL FUSE 3.3.1.34


B Valve 1/2f - 1/2f
C FLEXIBLE HOSE 500 1/2M 1/2F 3.3.1.33
D Union fitting 1/2" Nr 280 not supplied
E Reg 1/2f i: 20-100, o: 10-300 mbar
F Sol. valve NC 2way 1/2 -1/2
G Steel tube 1/2", length 100 mm not supplied
H FITTING G1/2F - FERRULE 12MM 3.3.1.42
I FITTING FOR SOLDERING 12 G1/2 3.3.1.41
J Steel T 1/2" Nr 130 not supplied
K Steel elbow 90° 1/2" Nr 90 not supplied
P Steel tube 1/2", length 230 mm not supplied

B + E + F compose the GAS SUPPLY KIT G20/25 2 SPEED (RS AME 2 EG) (3.3.1.36)

ALTERNATIVE : Possibility of removing C and replacing G, H and I by


Q " METALLIC HOSE G1/2F 700mm " (3.3.1.31)
+ R " UNION FITTING R1/2m-G1/2m " (3.3.1.25)
(see 4.6.2.8 – Example 2)
4- INSTALLATION
[Distribution pressure (PG) = inlet pressure to heaters (p)] : PROPANE

I H G F D K P

I H G F D D C B

J A

A THERMAL FUSE 3.3.1.34


B Valve 1/2f - 1/2f
C FLEXIBLE HOSE 500 1/2M 1/2F 3.3.1.33
D Union fitting 1/2" Nr 280 not supplied
F Sol. valve NC 2way 1/2 -1/2
G Steel tube 1/2", length 100 mm not supplied
H FITTING G1/2F - FERRULE 12MM 3.3.1.42
I FITTING FOR SOLDERING 12 G1/2 3.3.1.41
J Steel T 1/2" Nr 130 not supplied
K Steel elbow 90° 1/2" Nr 90 not supplied
P Steel tube 1/2", length 230 mm not supplied

B + F compose the GAS SUPPLY KIT PROPANE 2 SPEED (RS 2 PR Rp1/2) (3.3.1.40)

ALTERNATIVE : Possibility of removing C and replacing G, H and I by


Q " METALLIC HOSE G1/2F 700mm " (3.3.1.31)
+ R " UNION FITTING R1/2m-G1/2m " (3.3.1.25)
(see 4.6.2.8 – Example 2)
4- INSTALLATION
4.6.2.6-DOUBLE SPEED B64-2 KOMFORT HEATERS, WITH INDIVIDUAL
SOLENOID VALVES

[Distribution pressure (PG) > inlet pressure to heaters (p)] : NATURAL GAS

O I

I H G F D K G

N E D C B
K D
M F D

J A

A THERMAL FUSE 3.3.1.34


B Valve 1/2f - 1/2f
C FLEXIBLE HOSE 500 1/2M 1/2F 3.3.1.33
D Union fitting 1/2" Nr 280 not supplied
E Reg 1/2f i: 20-100, o: 10-300 mbar
F Sol. valve NC 2way 1/2 -1/2
G Steel tube 1/2", length 100 mm not supplied
H FITTING G1/2F - FERRULE 12MM 3.3.1.42
I FITTING FOR SOLDERING 12 G1/2 3.3.1.41
J Steel T 1/2" Nr 130 not supplied
K Steel elbow 90° 1/2" Nr 90 not supplied
M Steel tube 1/2" not supplied
N Steel tube 1/2", length 220 mm not supplied
O 90° ELBOW G1/2F - FERRULE 12MM 3.3.1.43

B + E + F compose the GAS SUPPLY KIT G20/25 2 SPEED (RS AME 2 EG) (3.3.1.36)
4- INSTALLATION
ª Alternative with KOMBI KIT

O I

I H G L
D C B

N
K M
A

A THERMAL FUSE 3.3.1.34


B Valve 1/2f - 1/2f
C FLEXIBLE HOSE 500 1/2M 1/2F 3.3.1.33
D Union fitting 1/2" Nr 280 not supplied
G Steel tube 1/2", length 100 mm not supplied
H FITTING G1/2F - FERRULE 12MM 3.3.1.42
I FITTING FOR SOLDERING 12 G1/2 3.3.1.41
K Steel elbow 90° 1/2" Nr 90 not supplied
L Kombiblock 1/2f 2 speed
M Steel tube 1/2" not supplied
N Steel tube 1/2", length 220 mm not supplied
O 90° ELBOW G1/2F - FERRULE 12MM 3.3.1.43

B + L compose the KOMBI KIT G20/G25 2 SPEED (RS AME 2/B EG) (3.3.1.38)
4- INSTALLATION
[Distribution pressure (PG) = inlet pressure to heaters (p)] : PROPANE

O I

I H G F D K G

C B
N
K M F D D

J A

A THERMAL FUSE 3.3.1.34


B Valve 1/2f - 1/2f
C FLEXIBLE HOSE 500 1/2M 1/2F 3.3.1.33
D Union fitting 1/2" Nr 280 not supplied
F Sol. valve NC 2way 1/2 -1/2
G Steel tube 1/2", length 100 mm not supplied
H FITTING G1/2F - FERRULE 12MM 3.3.1.42
I FITTING FOR SOLDERING 12 G1/2 3.3.1.41
J Steel T 1/2" Nr 130 not supplied
K Steel elbow 90° 1/2" Nr 90 not supplied
M Steel tube 1/2" not supplied
N Steel tube 1/2", length 220 mm not supplied
O 90° ELBOW G1/2F - FERRULE 12MM 3.3.1.43

B + F compose the GAS SUPPLY KIT PROPANE 2 SPEED (RS 2 PR Rp1/2) (3.3.1.40)
4- INSTALLATION
4.6.2.7- DOUBLE SPEED B64-2 SX HEATERS, WITH INDIVIDUAL SOLENOID
VALVES

[Distribution pressure (PG) > inlet pressure to heaters (p)] : NATURAL GAS

I H G F D K P

I H G F D E D C B

J A

A THERMAL FUSE 3.3.1.34


B Valve 1/2f - 1/2f
C FLEXIBLE HOSE 500 1/2M 1/2F 3.3.1.33
D Union fitting 1/2" Nr 280 not supplied
E Reg 1/2f i: 20-100, o: 10-300 mbar
F Sol. valve NC 2way 1/2 -1/2
G Steel tube 1/2", length 100 mm not supplied
H FITTING G1/2F - FERRULE 12MM 3.3.1.42
I FITTING FOR SOLDERING 12 G1/2 3.3.1.41
J Steel T 1/2" Nr 130 not supplied
K Steel elbow 90° 1/2" Nr 90 not supplied
P Steel tube 1/2", length 242 mm not supplied

B + E + F compose the GAS SUPPLY KIT G20/25 2 SPEED (RS AME 2 EG) (3.3.1.36)

ALTERNATIVE : Possibility of removing C and replacing G, H and I by


Q " METALLIC HOSE G1/2F 700mm " (3.3.1.31)
+ R " UNION FITTING R1/2m-G1/2m " (3.3.1.25)
(see 4.6.2.8 – Example 2)
4- INSTALLATION
[Distribution pressure (PG) = inlet pressure to heaters (p)] : PROPANE

I H G F D K P

I H G F D D C B

J A

A THERMAL FUSE 3.3.1.34


B Valve 1/2f - 1/2f
C FLEXIBLE HOSE 500 1/2M 1/2F 3.3.1.33
D Union fitting 1/2" Nr 280 not supplied
F Sol. valve NC 2way 1/2 -1/2
G Steel tube 1/2", length 100 mm not supplied
H FITTING G1/2F - FERRULE 12MM 3.3.1.42
I FITTING 12 12G DE 3.3.1.41
J Steel T 1/2" Nr 130 not supplied
K Steel elbow 90° 1/2" Nr 90 not supplied
P Steel tube 1/2", length 242 mm not supplied

B + F compose the GAS SUPPLY KIT PROPANE 2 SPEED (RS 2 PR Rp1/2) (3.3.1.40)

ALTERNATIVE : Possibility of removing C and replacing G, H and I by


Q " METALLIC HOSE G1/2F 700mm " (3.3.1.31)
+ R " UNION FITTING R1/2m-G1/2m " (3.3.1.25)
(see 4.6.2.8 – Example 2)
4- INSTALLATION
4.6.2.8- ALTERNATIVES WITH FLEXIBLE ON THE HEATER

Example 1

Q R

Q METALLIC HOSE G1/2F 700mm 3.3.1.31


R UNION FITTING R1/2m-G1/2m 3.3.1.25

Example 2

Q R

Q METALLIC HOSE G1/2F 700mm 3.3.1.31


R UNION FITTING R1/2m-G1/2m 3.3.1.25

Use of the UNION FITTING R1/2m-G1/2m see (10.4).


4- INSTALLATION
4.6.3- CONNECTION OF ACCESSORIES

4.6.3.1- GAS FILTERS

For fitting and connecting gas filters, please refer to the instructions supplied
with them.
4.6.3.2- SOLENOID VALVES

When connecting them to the piping, make sure that the gas flow direction
is in accordance with the following illustrations.
ª SOL.VALVE 8X13 - Rp 1/4" (3.3.1.16)

Direction of gas
flow

ª SOL.VALVE 15X21 - Rp 1/2" (3.3.1.17)

Direction of gas
flow

ª SOL.VALVE 20X27 - Rp 3/4" (3.3.1.18)

Direction of gas
flow
4- INSTALLATION
ª SOL.VALVE 26X34 - Rp 1" (3.3.1.19)

Direction of gas
flow

ª SOL.VALVE 33X42 - Rp 1 1/4" (3.3.1.20)

Direction of gas
flow
4- INSTALLATION
ª SOL.VALVE 40X49 - Rp 1 1/2" (3.3.1.21)

Direction of gas
flow

ª SOL.VALVE 50X60 - Rp 2" (3.3.1.22)

Direction of gas
IN

flow
4- INSTALLATION
4.6.4- CLEAN OUT

4.6.4.1- OBJECTIVE

Flush out impurities in gas piping.

4.6.4.2- PRINCIPLE

Clean out gas piping with dry air, or better, with nitrogen, after disconnecting
all accessories.

1 Pressure on

1 2 3 4
2 Flush out outlet n°1

1
3 Flush out outlet n°2

2
= OPEN VALVE

= CLOSED VALVE
4- INSTALLATION
4.6.5- GAS TIGHTNESS TEST

4.6.5.1- OBJECTIVE

Test the installation when pressurised and detect any possible leak.

4.6.5.2- PRINCIPLE

Solenoid valve open

1 The installation is
pressurised after the
heater individual valves
have been closed.

Pressure gauge

Dry air or nitrogen


1,5 x PG

Solenoid valve open

2 Close the main


gas valve.
Wait 15 minutes for the
pressure to stabilise.
Check the pressure on
the pressure gauge
Pressure gauge

Solenoid valve open

3 Keep pressurised for 2


hours.
If the pressure drops,
detect leaks using soap
water (or equivalent
fluid), fix them and
repeat the test. Pressure gauge

OPEN This principle is only a guideline.


Local regulations may apply.
CLOSED
4- INSTALLATION
4.7- ELECTRICAL WIRING

4.7.1- ELECTRICAL EQUIPMENT

ª Electrical equipment and cables must not be located within the heated area
around the heater (see diagram below).

HEATED
AREA
1m 0.2m

2m

HEATED AREA

ª Use a NEUTRAL conductor, or install an ISOLATION TRANSFORMER.


4- INSTALLATION
4.7.2- WIRING DIAGRAM
4.7.2.1- MT100

DIN rail 35 mm Ground terminal


Ground-fault breaker

MT100

Watertight
enclosure Fuse 4A gl max.

Connect all ground wires


to the ground terminal.

230V ~ (L+N+G)
Ground-fault
Ground terminal breaker
Sensor cable

MT100

External safety Fuse 4A gl max.


or
switch (NC)

RP3 + fuse 0.25A Bridge (included in the sensor plastic bag) Solenoid valve

RP3 + fuse 0.25A

SX heater B48-2SX, B64-2SX heaters


"single speed" used as "single speed"

Sensor
(supplied with module)
4- INSTALLATION
4.7.2.2- MT100 DE

DIN rail 35 mm Ground terminal


Ground-fault breaker

MT100 DE

Watertight
enclosure 2 fuses 4A gl max.

Connect all ground wires


to the ground terminal.

230V ~ (L+N+E)
Ground-fault
Ground terminal breaker
Sensor cable

MT100 DE

External safety 2 fuses 4A gl max.


or
switch (NC)

RP32 + 2 fuses 0.25A Bridge (included in the sensor plastic bag)

Solenoid valve

SX or KOMFORT heater
"single speed"

Sensor
(supplied with module)
4- INSTALLATION
4.7.2.3- MTH100

DIN rail 35 mm Ground terminal Pull the protective strip off the battery.
Ground-fault breaker

MTH100

Watertight
enclosure Fuse 4A gl max.

Connect all ground wires


to the ground terminal. Ground terminal

230V ~ (L+N+E)
External push-button (NO) Ground-fault
as optional extra (not supplied by SBM) breaker
Sensor cable

MTH100

External safety Fuse 4A gl max.


or
switch (NC)

Bridge (included in the sensor plastic bag)


RP3 + fuse 0.25A Solenoid valve

RP3 + fuse 0.25A

SX heater B48-2SX, B64-2SX heaters


"single speed" used as "single speed"

Sensor
(supplied with module)
4- INSTALLATION
4.7.2.4- MTH100 DE

DIN rail 35 mm Ground terminal Pull the protective strip off the battery.
Ground-fault breaker

MTH100 DE

Watertight
enclosure 2 fuses 4A gl max.

Connect all ground wires Ground terminal


to the ground terminal.

230V ~ (L+N+E)
External push-button (NO) Ground-fault
as optional extra (not supplied by SBM) breaker

Sensor cable

MTH100 DE

2 fuses 4A gl max.
External safety
or
switch (NC)

RP32 + 2 fuses 0.25A Bridge (included in the sensor plastic bag)

Solenoid valve

SX or KOMFORT heater
"single speed"

Sensor
(supplied with module)
4- INSTALLATION
4.7.2.5- MT150

DIN rail 35 mm Ground terminal


Ground-fault breaker

MT150

Watertight
enclosure Fuse 4A gl max.

Connect all ground wires


to the ground terminal.

230V ~ (L+N+E)
Ground-fault
Ground terminal breaker
Sensor cable

MT150

External safety Fuse 4A gl max.


RP3 + fuse 0.25A or
switch (NC)
Bridge (included in the sensor plastic bag)
50% line Solenoid valve

100% line
RP32 + 2 fuses 0.25A

Sensor SX heater 2SX heater


(supplied with module) "single speed" "double speed"
4- INSTALLATION
4.7.2.6- MT150 DE

DIN rail 35 mm Ground terminal


Ground-fault breaker

MT150 DE

Watertight
enclosure 3 fuses 4A gl max.

Connect all ground wires


to the ground terminal.

230V ~ (L+N+E)
Ground-fault
Ground terminal breaker
Sensor cable

MT150 DE

External safety 3 fuses 4A gl max.


RP32 + 2 fuses 0.25A switch (NC) or

Bridge (included in the sensor plastic bag)


50% line

100% line

Solenoid valve

SX heater 2SX or 2KOMFORT heater


"single speed" "double speed"

Sensor
(supplied with module)
4- INSTALLATION
4.7.2.7- MTH150

DIN rail 35 mm Ground terminal Pull the protective strip off the battery.
Ground-fault breaker

MTH150

Watertight
enclosure Fuse 4A gl max.

Connect all ground wires


to the ground terminal. Ground terminal

230V ~ (L+N+E)
External push-button (NO) Ground-fault
as optional extra (not supplied by SBM) breaker
Sensor cable

MTH150

RP3 + fuse 0.25A External safety Fuse 4A gl max.


or
switch (NC)
Bridge (included in the sensor plastic bag)
50% line
Solenoid valve

100% line
RP32 + 2 fuses 0.25A

Sensor SX heater 2SX heater


(supplied with module) "single speed" "double speed"
4- INSTALLATION
4.7.2.8- MTH150 DE

DIN rail 35 mm Ground terminal Pull the protective strip off the battery.
Ground-fault breaker

MTH150 DE

Watertight
enclosure 3 fuses 4A gl max.

Connect all ground wires


to the ground terminal. Ground terminal

230V ~ (L+N+E)
External push-button (NO) Ground-fault
as optional extra (not supplied by SBM) breaker
Sensor cable

MTH150 DE

External safety 3 fuses 4A gl max.


RP32 + 2 fuses 0.25A switch (NC) or

Bridge (included in the sensor plastic bag)


50% line

100% line

Solenoid valve

SX heater 2SX or 2KOMFORT heater


"single speed" "double speed"

Sensor
(supplied with module)
4- INSTALLATION
4.7.3- TYPES OF CABLES

CONNECTION CABLE
Main breaker to control module
3 conductor (or 5) insulated with ground.
(MT - MTH)
Section of each wire : 1.5 mm2
Control module to RP3 or RP32 U1000 RO2V or SJ-16 or equivalent.
(refer to standards applicable in your country)
Control module to solenoid valves
Use the prewired plug(s), 1m or 3m long,
HO5 - RNF 3x0.75 mm2 supplied with the
heater.
RP3 and RP32 to heater
Green / yellow wire : EARTH / GROUND
Blue wire : NEUTRAL
Brown wire : LIVE
Control module to sensor
Control module to Use ROLL SENSOR CABLE (3.3.2.4)
external push-button (supplied by SBM)

Control module to Maximum length = 300 m


external safety switch

Always use 3 conductor cables with insulated ground.


(no bare ground)

For countries where the prewired plug is not supplied with the heater, please
order separately : PREWIRED PLUG 1M/3FT (see 8.1).

230 VAC between LIVE and NEUTRAL :

All the SBM automatic heaters are protected by a fuse


on the LIVE only.

Therefore, it is essential to be consistent with the color codes such that


there is a continuity in all LIVE and NEUTRAL wires.

Inverting LIVE and NEUTRAL wires would eliminate all fuse protection.
4- INSTALLATION
4.7.4- WIRING OF CONTROL MODULES
4.7.4.1- MT100

Ground-fault
breaker
To temperature
sensor P/L1 N/L2

Cable shield
STRIPPING OF SENSOR CABLE
25 mm

7 mm

1 2 3 4 5
Cable shield
or

To safety P/L1 N/L2 P/L1 N/L2


switch
To heaters To solenoid valve(s)
Connect a safety switch to terminals 1 and 3
(via RP3)
of control module MT100 or insert the bridge
supplied with the module.

4.7.4.2- MT100 DE

Ground-fault
breaker
To temperature
sensor
P/L1 N/L2

Cable shield
STRIPPING OF SENSOR CABLE
25 mm

7 mm

1 2 3 4 5
Cable shield
or

To safety P/L1 N/L2 P/L1 N/L2


switch

To solenoid valves To heaters


(via RP32) (via RP32)
Connect a safety switch to terminals 1 and 3
of control module MT100 DE or insert the bridge
supplied with the module.
4- INSTALLATION
4.7.4.3- MTH100

Ground-fault
To external breaker
To temperature push-button
sensor (optional) P/L1 N/L2

Cable shield
STRIPPING OF SENSOR CABLE
25 mm

7 mm

1 2 3 4 5
Cable shield
or

P/L1 N/L2 P/L1 N/L2


To safety
switch
To heaters To solenoid valve(s)
(via RP3)
Connect a safety switch to terminals 1 and 3
of control module MTH100 or insert the bridge
supplied with the module.

4.7.4.4- MTH100 DE

To external Ground-fault
push-button breaker
To temperature (optional)
sensor P/L1 N/L2

Cable shield
STRIPPING OF SENSOR CABLE
25 mm

7 mm

1 2 3 4 5
Cable shield
or

To safety P/L1 N/L2 P/L1 N/L2


switch

To solenoid valves To heaters


(via RP32) (via RP32)
Connect a safety switch to terminals 1 and 3
of control module MTH100 DE or insert the bridge
supplied with the module.
4- INSTALLATION
4.7.4.5- MT150

Ground-fault
breaker
To temperature
sensor P/L1 N/L2

Cable shield
STRIPPING OF SENSOR CABLE
25 mm

7 mm

1 2 3 4 5
Cable shield
or

To safety P/L1 N/L2 P/L1 N/L2 P/L1 N/L2


switch
To heaters To heaters To solenoid
(via RP3 or RP32) (via RP3 or RP32) valve(s)
50% line 100% line

Connect a safety switch to terminals 1 and 3


of control module MT150 or insert the bridge
supplied with the module.

4.7.4.6- MT150 DE

Ground-fault
breaker
To temperature
sensor P/L1 N/L2

Cable shield
STRIPPING OF SENSOR CABLE
25 mm

7 mm

1 2 3 4 5
Cable shield
or
P/L1 N/L2 P/L1 N/L2 P/L1 N/L2
To safety
switch
To solenoid To solenoid To heaters
valves valves (via RP32)
(via RP32) (via RP32)
Connect a safety switch to terminals 1 and 3 50% line 100% line
of control module MT150 DE or insert the bridge
supplied with the module.
4- INSTALLATION
4.7.4.7- MTH150

Ground-fault
To external breaker
To temperature push-button
sensor (optional) P/L1 N/L2

Cable shield
STRIPPING OF SENSOR CABLE
25 mm

7 mm

1 2 3 4 5
Cable shield
or

To safety P/L1 N/L2 P/L1 N/L2 P/L1 N/L2


switch
To heaters To heaters To solenoid
(via RP3 or RP32) (via RP3 or RP32) valve(s)
50% line 100% line

Connect a safety switch to terminals 1 and 3


of control module MTH150 or insert the bridge
supplied with the module.

4.7.4.8- MTH150 DE

Ground-fault
To external breaker
To temperature push-button
sensor (optional) P/L1 N/L2

Cable shield
STRIPPING OF SENSOR CABLE
25 mm

7 mm

1 2 3 4 5
Cable shield
or
P/L1 N/L2 P/L1 N/L2 P/L1 N/L2
To safety
switch
To solenoid To solenoid To heaters
valves valves (via RP32)
(via RP32) (via RP32)
Connect a safety switch to terminals 1 and 3 50% line 100% line
of control module MTH150 DE or insert the bridge
supplied with the module.
4- INSTALLATION
4.7.5- SENSOR
4.7.5.1- LOCATION

To avoid any electrical


disturbance, the sensor must
be connected to the control
module using the SBM cable : Sensor
ROLL SENSOR CABLE (3.3.2.4)
h = 1.5 m

Heater
Provide protection (shield) for the
sensor if it is exposed to sun rays
or air draughts.

Wall or
pillar

Sensor cable

Ideal location

Minimum
distance : 2 cm
4- INSTALLATION
4.7.5.2- WIRING

9
D 22mm 4
13
9

- Slide A, B and C around the cable.


- Strip cable.
- Connect the cable to printed circuit D.
- Slide D into the sensor body E.
- Screw C into E tightly.
- Place B into C.
- Screw A into C.

4.7.5.3- EXTENSION OF SENSOR CABLE

From CONTROL MODULE

Shield Junction box


STRIPPING OF SENSOR CABLE
25 mm

7 mm

1 2 3 4 5
Shield Connector

To SENSOR
4- INSTALLATION
4.7.6- RP3 / RP32
4.7.6.1- NUMBER AND TYPE OF BOXES - NUMBER AND TYPE OF FUSES
HEATER SPEED(S) BOX(ES) FUSE(S)
B6 1 1 x RP3 1 x 0.25A
B8 1 1 x RP3 1 x 0.25A
B10 1 1 x RP3 1 x 0.25A
DIAGRAMS 1 to 16 B12 1 1 x RP3 1 x 0.25A
B16 1 1 x RP3 1 x 0.25A
B20 1 1 x RP3 1 x 0.25A
B24 1 1 x RP3 1 x 0.25A
B32 1 1 x RP3 1 x 0.25A
B48-2 1 1 x RP32 2 x 0.25A
B64-2 1 1 x RP32 2 x 0.25A
B24-2 2 1 x RP32 2 x 0.25A
B32-2 2 1 x RP32 2 x 0.25A
B48-2 2 1 x RP32 2 x 0.25A
B64-2 2 1 x RP32 2 x 0.25A
B6 1 1 x RP32 2 x 0.25A
B8 1 1 x RP32 2 x 0.25A
B10 1 1 x RP32 2 x 0.25A
DIAGRAMS 17 to 20

B12 1 1 x RP32 2 x 0.25A


B16 1 1 x RP32 2 x 0.25A
B20 1 1 x RP32 2 x 0.25A
B24 1 1 x RP32 2 x 0.25A
B32 1 1 x RP32 2 x 0.25A
B24-2 2 2 x RP32 4 x 0.25A
B32-2 2 2 x RP32 4 x 0.25A
B48-2 2 2 x RP32 4 x 0.25A
B64-2 2 2 x RP32 4 x 0.25A

4.7.6.2- MOUNTING OF RP3 AND RP32

60 mm

60 mm

Always place the plastic cover


back on top of the screw head

The RP3 or RP32 box must be located no more than one metre away from the
ignition block (BA block) of the heater, as the prewired plug is 1 m long.
It must not be located in the heated area around the heater (see 4.7.1).
4- INSTALLATION
4.7.6.3- ELECTRICAL WIRING OF RP3

N / L1
N / L1

PREVIOUS RP3 NEXT RP3


2 2
3x1.5 mm 3x1.5 mm

Ph / L2
Ph / L2

Fuse N / L1
see (4.7.6.1)

Ph / L2
Prewired plug

HEATER

4.7.6.4- ELECTRICAL WIRING OF RP32

ª Diagrams 1 to 16 ("double speed" heaters)


50% and 100%
Ph / L2 N / L1 connections : use
2 cables 3x1.5 or
Ph / L2 N / L1 1 cable 5x1.5

PREVIOUS RP32 100% NEXT RP32


2 2
5x1.5 mm 5x1.5 mm
Fus100

N / L1
N / L1
Ph / L2 50%
Fus50
Ph / L2
Fuses
see (4.7.6.1) 50% 100%
Ph / L2
Ph / L2 N / L1
N / L1

Prewired plugs

50% 100%

HEATER
4- INSTALLATION
ª Diagrams 1 to 16 (B48, B64 heaters used as "single speed")

Ph / L2 N / L1
Ph / L2 N / L1

PREVIOUS RP32 NEXT RP32


2 2
3x1.5 mm 3x1.5 mm

N / L1
Ph / L2

Fuses
see (4.7.6.1)
Ph / L2
Ph / L2 N / L1
N / L1

Prewired plugs

HEATER

ª Diagrams 17 and 18

Heaters and solenoid


Ph / L2 N / L1 valves connections : use
Ph / L2 N / L1
2 cables 3x1.5 or
1 cable 5x1.5.

PREVIOUS RP32 EV NEXT RP32

2 2
5x1.5 mm 5x1.5 mm
Fus EV

N / L1
N / L1
Ph / L2 Rad.
FusRad.
Ph / L2
Fuses
see (4.7.6.1) Rad. EV
Ph / L2
Ph / L2 N / L1
N / L1

Prewired plug

HEATER SOLENOID VALVE


4- INSTALLATION
ª Diagrams 19 and 20

RP32 FOR CONNECTION OF SOLENOID VALVES


50% and 100%
Ph / L2 N / L1 connections : use
2 cables 3x1.5 or
Ph / L2 N / L1
1 cable 5x1.5

PREVIOUS RP32 100% NEXT RP32


2 2
5x1.5 mm 5x1.5 mm

Fus100
N / L1
N / L1
Ph / L2 50%
Fus50
Ph / L2
Fuses
see (4.7.6.1) 50% 100%
Ph / L2
Ph / L2 N / L1
N / L1

50% 100%

SOLENOID VALVES

RP32 FOR CONNECTION OF HEATER

Ph / L2 N / L1
Ph / L2 N / L1

PREVIOUS RP32 NEXT RP32


2 2
3x1.5 mm 3x1.5 mm

N / L1
Ph / L2

Fuses
see (4.7.6.1)
Ph / L2
Ph / L2 N / L1
N / L1
Prewired plugs

HEATER
4- INSTALLATION
4.7.7- SOLENOID VALVES

4.7.7.1- WIRING

For the electrical wiring of the solenoid valves, please refer to the instructions
supplied with them.

4.7.7.2- POSITION OF THE CONNECTOR

The cable should preferably come out of the bottom of the connector. If this is
not possible, due to the shape of the solenoid valve, it should come out of the
side.

Yes Yes

RIsk of moisture penetration.

No
4- INSTALLATION
4.7.8- WIRING OF HEATERS
4.7.8.1- DIAGRAM

RP3 (3.3.2.1)
RP32 (3.3.2.2)
Fuse(s) (3.3.2.3)
The prewired plug must not be located
in the heated area around the heater
(see 4.7.1).

Prewired plug 1 m
(supplied with the heater)

4.7.8.2- WIRING

Loosen the nut(s) which fix the cover.


1 (3 turns)

2 Remove the cover.


4- INSTALLATION

3 Fit the plug onto the BA block.

4 Tighten the plug screw.

5 Put the cover back into position.

6 Tighten the nut(s) fixing the cover.


4- INSTALLATION
4.8- FIRST START UP (BY THE INSTALLER)

4.8.1- AUTOMATIC SX OR KOMFORT HEATERS

4.8.1.1- PRELIMINARY CHECKS

ª Size of control unit fuses.

ª Ground-fault breaker operation (‘’TEST’’ button).

4.8.1.2- INITIAL SETTINGS

ª Main gas valve closed.

ª Individual valves open.

ª Ground-fault breaker set to "ON".

ª Control module set correctly (see 5.1)

4.8.1.3- IGNITION

* Manual operation

ª Open the main gas valve

ª Start the heater ignition cycle :

- Open the solenoid valve (if available)

- Press on the ignition push button for 45 seconds.

- If the heater is not lit after 45 seconds, start a second


ignition cycle.

- If the heater is still not lit or goes out, refer to section


"7- TROUBLE-SHOOTING".

* Automatic control

ª Open the main gas valve.

ª Check the settings (temperature, time)


and, if necessary, change the module programming (see 5.1).

ª Run a full heating cycle and check :

- ignition cycle length (45 seconds max.)

- ignition and shut-off of heaters according to temperature settings.


4- INSTALLATION
4.8.1.4- SETTING THE INJECTION PRESSURE

If adjustable regulator/governors are used, the injection pressure of


each heater must be set to the value indicated in the corresponding tables :
see sections 3.1.2 and 3.1.4.

Adjustable regulator/governor Pressure test point

Inlet pressure p

Injection pressure
(pressure test point)

Procedure :

ª Unscrew the pressure test point screw (2 or 3 turns)

ª Connect a pressure gauge (adapted to the value to be measured)


to the pressure test point.

ª Adjust the value of the injection pressure read off the gauge by turning the
regulator/governor adjustment screw (see regulator/governor instructions).

ª Remove the pressure gauge.

ª Re-tighten the pressure test point screw.

ª For double speed heaters, repeat the same operation with the second
pressure test point.

Do not forget to re-tighten the pressure test point screw.

Injection pressures must be set while all the heaters are running.
4- INSTALLATION
4.8.2- M MANUAL HEATERS

4.8.2.1- INITIAL SETTINGS

ª Main gas valve closed.

ª Individual valves closed.

4.8.2.2- IGNITION

ª Open the main gas valve.

ª Open the individual valve of the heater to be lit.

ª Press the push-button while holding a flame against the ceramic surface
of the heater.

Do not hold your face close to the


ceramic surface during ignition.

Keep pressing the push-button during 20 seconds.

4.8.2.3- SETTING THE INJECTION PRESSURE

If adjustable regulators/governors are used, the injection pressure of


each heater must be set to the value indicated in the corresponding tables :
see section 3.1.6.

The procedure for adjusting the pressure is the same as that for the automatic
heaters : see 4.8.1.4.
4- INSTALLATION
4.9- RECEIPT OF INSTALLATION

RECEIPT OF THE INSTALLATION MUST BE PERFORMED BY


THE INSTALLER, IN PRESENCE OF THE CUSTOMER.

4.9.1- AUTOMATIC SX OR KOMFORT HEATERS

ª Check that the gas type and pressure comply with the type of heater installed
(refer to rating plate on heater).

ª Check that an individual valve is installed prior to each heater.

ª Check that the " SX (or KOMFORT) USER GUIDE "


(Manual operation or Automatic control)
is displayed next to the control unit, after being stamped by the installer.

ª Provide the customer with a copy of the


"SX (or KOMFORT) USER INSTRUCTIONS" supplied in each heater box.

ª Indicate to the customer the location of :

- valves
- electric switches
- control units.

ª Explain to the customer how all control units operate.

ª Plan the initial maintenance visit (1 year after start-up).

4.9.2- MANUAL M HEATERS

ª Check that the gas type and pressure comply with the type of heater installed
(refer to rating plate on heater).

ª Check that an individual valve is installed prior to each heater.

ª Check that the " M USER GUIDE " is displayed at a convenient location,
after being stamped by the installer.

ª Provide the customer with a copy of the "M USER INSTRUCTIONS ", supplied
in each heater box.

ª Indicate to the customer the location of the valves.

ª Explain to the customer how the heaters operate.

ª Plan the initial maintenance visit (1 year after start-up).


CERAMIC
HEATING

OPERATION 5

5.1- PROGRAMMING THE CONTROL MODULE

5.2- OPERATING DIAGRAMS

5.3- SAFETY SWITCH

- Return to SUMMARY -
5- OPERATION
5.1- PROGRAMMING THE CONTROL MODULE

5.1.1- MT100 MODULE

5.1.1.1- FUNCTIONS

Digital display Push-buttons for programming

Display indicators

The digital display shows alternately :

INFORMATION INDICATOR DISPLAY

Temperature T
Set temperature C

0%
Heating level P or
100%

5.1.1.2- TEMPERATURE SETTING

Use push-buttons as follows :

Go to temperature setting mode

and Increase or decrease the set


temperature. ( C blinking )

Go back to normal operation


5- OPERATION
5.1.2- MT150 MODULE

5.1.2.1- FUNCTIONS

Digital display Push-buttons for programming

Display indicators

Displayed for 3.5 seconds when the module is switched on :

Then, the digital display shows alternately :

INFORMATION INDICATOR DISPLAY

Temperature T
Set temperature C

0%
or
Heating level P 50%
or
100%

5.1.2.2- TEMPERATURE SETTING

Use push-buttons as follows :

Go to temperature setting mode


5- OPERATION
and Increase or decrease the set
temperature. ( C blinking )

Go back to normal operation

5.1.2.3- HOW TO MODIFY DELTA 50% - 100%

Delta is preset to 1°C.


It can be modified to a value from 1°C to 3°C, in 0.5°C steps.

In such case, follow the procedure below :

Before switching the module on, press simultaneously :

and

Hold down and switch the module on.

Display : .

Hold down until the display shows :

Push simultaneously : and

Push :

Push simultaneously : and

Display : with d blinking

Push :

Display : (preset value of Delta)

Push : to increase Delta.

Push : to go back to normal operation.


5- OPERATION
5.1.3- MTH100 / MTH150 MODULES

5.1.3.1- FRONT OF MODULES MTH 4 control buttons


Display

5.1.3.2- DISPLAYS OF MODULES MTH

Displayed for 3.5 seconds when the module is switched on :

FIRST SETTING ? (see 5.1.3.8- Customisation)


yes (M)

Then display 1 alternates with display 2.

BATTERY (see 5.1.3.9)


If display is :

Day and date Month Time Temperature

DISPLAY 1
Alternates with Sa 01 Jan 00:00 15.6°C
display 2 for menu (M)

Menu access

Setpoint Regulation Heating


temperature : mode : indicator :
Tc = Comfort Auto 100%
or Tr = Reduced or Maxi or 50% (MTH150 only)
or Tn = Night or Mini or 0%

DISPLAY 2
Alternates with
Tc=17° * REG:auto – 100%
display 1 modify REG (+ -)
Preset mode (see
5.1.3.7)
Alternating display of current setpoint and Ex
Tc/Ex = 17° indicates that today's date has been programmed as
(see 5.1.3.9) an exceptional date or period.
XX = 00° Indicates that MENU B is not programmed

to access the various MENUS


5- OPERATION
5.1.3.3- MENUS

Nr MENU FUNCTION
A ADJUST SETPOINTS ? Setting the 3 temperature setpoints Tc, Tr and Tn.
Programming the 7days of the week
B WEEKDAY PROGRAMMING ? 7 programming steps per day.
C COPY WEEKDAY PROG. ? Copying one day's programme to another.
D EXCEPTIONAL DATE ? Assigning an exceptional programme to a specific date.
E EXCEPTIONAL PERIODE ? Assigning an exceptional programme to a specific period.
Entering 2 daily programmes E1 and E2 which can be used
F EXCEPT. PROGRAMME ? for exceptional dates or periods.
G CLOCK SETTING ? Setting year, month, date, hour and minute.
Heating time counter
H HEATING TIME ? (100% and 50% for the module MTH150).

5.1.3.4- PROGRAMMING PROCEDURE

Before programming your control module, consult the following example


and fill in the programming grid (see 5.1.3.5).

This example is not programmed in the module.


By default, the 3 setpoints Tc, Tr and Tn are set at "00°C", the 7 steps of the
7 days of the week are set at "00:00=Clr" and all the dates are set at "00 jan 01"
(1st January 2000).

ª ADJUST SETPOINTS (MENU A)

To make optimum use of your heating, there are 3 available temperature


setpoints :

Tc : Comfort temperature (ex : working day in the factory).


Tr : Reduced temperature (ex : preheating half an hour before
worker's arrival).
Tn : Night temperature (ex : to prevent freezing outside factory
working hours).

See programming grid (5.1.3.5)

ª WEEKDAY PROGRAMMING (MENUS B and C)

Specify a typical timetable for each day of the week (Monday to Sunday)

Example of programming for Monday :

- Before 07:00 : factory closed (Tn setpoint maintained since the day before).
- 07:00 - 07:30 : preheating half an hour before workers ' arrival (setpoint Tr).
- 07:30 - 12:00 and 13:00 - 17:15 : working day (setpoint Tc).
- 12:00 - 13:00 : lunch break (setpoint Tr).
- After 17:15 : factory closed (setpoint Tn until new programming step)
5- OPERATION
Setpoint Tr Tc Tr Tc Tn
Step 1 2 3 4 5
Time 07:00 07:30 12:00 13:00 17:15

Tn Tr Tc Tr Tc Tn

Step programming is only required with a setpoint change.

Example : programming is not required on Monday at 00:00 since the heating


is already set to Tn (as from Friday 11:30).

See programming grid (5.1.3.5)

ª EXCEPTIONAL DATES (MENU D)

10 exceptional dates are available to pre-programme your heating on dates


where timetable differs from the one set for the corresponding day :
public holidays, inventory days, make-up days, etc...

Assign one of the following programmes to each of these dates : Sunday


(normal non-working day), Monday (normal working day), E1 or E2
(see exceptional programmes)

Example : Christmas day (Tuesday 25 december)


Although Christmas Day is on a Tuesday, it is a public holiday
and therefore heating is programmed as for Sundays
(Tn temperature).

Adjust your exceptional dates as and when required.


Fixed-date holidays (e.g. Christmas) are programmed once and for always.
Variable-date holidays (e.g. Easter Monday) must be re-programmed every year.

See programming grid (5.1.3.5)

ª EXCEPTIONAL PERIODE (MENU E)

The same principle applies as with exceptional dates : one exceptional period
is available for special programming over a several day period.

Example : Holidays (from 04 to 10 February)


To programme as a Sunday (Tn temperature).

Adjust your exceptional period as and when required.


The programming of an exceptional period overrides the programming of
an exceptional date or normal days when these are included in the exceptional period.

See programming grid (5.1.3.5)


5- OPERATION
ª EXCEPTIONAL PROGRAMMES (MENU F)

There are two exceptional programmes E1 and E2 available


(in addition to normal Sundays and Mondays).
Each of these two programmes has 7 steps.
These two programmes are for attributing to an exceptional date or period.

Example : Friday 4 january


Make-up day for 24 december. Clock out at 16:00 instead of 11:30.

See programming grid (5.1.3.5) programme E1


5- OPERATION
5.1.3.5- PROGRAMMING GRID

Example :
A ADJUST SETPOINTS Tc = 17ºC Tr = 10ºC Tn = 05ºC
WEEKDAY PROGRAMMING
Step Nr 01 Nr 02 Nr 03 Nr 04 Nr 05 Nr 06 Nr 07

Setpoint

Setpoint

Setpoint

Setpoint

Setpoint

Setpoint

Setpoint
B Time Time Time Time Time Time Time
DAYS
hh:mm hh:mm hh:mm hh:mm hh:mm hh:mm hh:mm

Monday 07:00 Tr 07:30 Tc 12:00 Tr 13:00 Tc 17:15 Tn 00:00 Clr 00:00 Clr
Tuesday 07:00 Tr 07:30 Tc 12:00 Tr 13:00 Tc 17:15 Tn 00:00 Clr 00:00 Clr
Wednesday 07:00 Tr 07:30 Tc 12:00 Tr 13:00 Tc 17:15 Tn 00:00 Clr 00:00 Clr
Thursday 07:00 Tr 07:30 Tc 12:00 Tr 13:00 Tc 17:15 Tn 00:00 Clr 00:00 Clr
C
Friday 07:00 Tr 07:30 Tc 11:30 Tn 00:00 Clr 00:00 Clr 00:00 Clr 00:00 Clr
Saturday 00:00 Clr 00:00 Clr 00:00 Clr 00:00 Clr 00:00 Clr 00:00 Clr 00:00 Clr
Sunday 00:00 Clr 00:00 Clr 00:00 Clr 00:00 Clr 00:00 Clr 00:00 Clr 00:00 Clr
EXCEPTIONAL DATES
Nr Date Prog. Observations Nº Date Prog. Observations
01 06 Aug Su August Bank Holiday 06 04 Jan E1 Make-up for 24 Dec
D 02 24 Dec E2 afternoon 24 Dec to make up 07 11 Jan E1 Make-up for 31 Dec
03 25 Dec Su Christmas (Tuesday) 08 25 Jan Mo Inventory (Friday)
04 31 Dec E2 afternoon 31 Dec to make up 09 26 Jan Mo Inventory (Saturday)
05 01 Jan Su New Year's Day (Tuesday) 10
E EXCEPTIONAL PERIOD from : 04 February to : 10 February Prog = Su (holidays)
EXCEPTIONAL PROGRAMMES
F E1 07:00 Tr 07:30 Tc 12:00 Tr 13:00 Tc 16:00 Tn 00:00 Clr 00:00 Clr
E2 07:00 Tr 07:30 Tc 12:00 Tn 00:00 Clr 00:00 Clr 00:00 Clr 00:00 Clr

"Clr" (Clear) : is displayed as setpoint when there is no programmed value.

Empty grid to prepare your programme :


A ADJUST SETPOINTS Tc = ºC Tr = ºC Tn = ºC
WEEKDAY PROGRAMMING
Step Nr 01 Nr 02 Nr 03 Nr 04 Nr 05 Nr 06 Nr 07
Setpoint

Setpoint

Setpoint

Setpoint

Setpoint

Setpoint

Setpoint
B Time Time Time Time Time Time Time
DAYS
hh:mm hh:mm hh:mm hh:mm hh:mm hh:mm hh:mm

Monday
Tuesday
Wednesday
Thursday
C
Friday
Saturday
Sunday
EXCEPTIONAL DATES
Nr Date Prog. Observations Nº Date Prog. Observations
01 06
D 02 07
03 08
04 09
05 10
E EXCEPTIONAL PERIOD from : to : Prog =
EXCEPTIONAL PROGRAMMES
F E1
E2
5- OPERATION
5.1.3.6- PROGRAMMING INPUT

Programming instructions are based on the example grid (see 5.1.3.5)

ª MENU A (ADJUST SETPOINTS)

DISPLAY QUESTIONS YOUR REPLY

NOTE : setpoints settings range from


ADJUST SETPOINTS ? 0º to 47 ºC in 1º C steps.
yes (M) / no (Î) The 3 setpoints are linked :
Tn cannot be greater than Tr
Tr cannot be greater than Tc

Tc = 00 * Tr = 00 * Tn = 00 °C
modify (+/-) / yes (Î) or To modify the flashing Tc value

To validate and move on to next value

Tc = 17 * Tr = 00 * Tn = 00 °C
modify (+/-) / yes (Î) or To modify the flashing Tr value

To validate and move on to next value

Tc = 17 * Tr = 10 * Tn = 00 °C
modify (+/-) / yes (Î) or To modify the flashing Tn value

On validation of Tn you go back to the


first MENU A display

ADJUST SETPOINTS ?
yes (M) / no (Î) To confirm programming and move on to
next menu
5- OPERATION
ª MENU B (WEEKDAY PROGRAMMING)

WEEKDAY PROGRAMMING ? Example of programming for Monday


yes (M) / no (Î) Setpoint
Step

Time

DAY :

Su * n° 01 Î 00 : 00 = Clr
next (+/-) / yes (Î) or To select the day of the week

To validate and move on to step no.

STEP No :

Mo * n° 01 Î 00 : 00 = Clr
To select the step no. of the day of the
next (+/-) / yes (Î) or
week

To validate

Mo * n° 01 Î 00 : 00 = Clr
modify (M) / exit (Î)

HOUR :
Mo * n° 01 Î 07 : 00 = Clr
modify (+/-) / yes (Î) or To select the hour

To validate and move on to minutes setting

MINUTES :
Mo * n° 01 Î 07 : 00 = Clr
modify (+/-) / yes (Î) or To select the minutes

To validate and move on to selection


of corresponding setpoint
5- OPERATION
SETPOINT :
Mo * n° 01 Î 07 : 00 = Tr For each possible step, select :
Tc : comfort Temperature
modify (+/-) / yes (Î)
Tr : reduced Temperature
Tn : night Temperature
Clr : Clear the programme step
(time + setpoint)

or To select the temperature setpoint

To validate and move on to next step

NEW STEP :
Mo * n° 01 Î 07 : 00 = Tr After each setpoint validation, the module
next (+/-) / yes (Î) automatically goes back to step no. 01.

or To select the next step

You will then move on to the


2nd programming step for Monday

Mo * n° 02 Î 00 : 00 = Clr
modify (M) / exit (Î) Validate and repeat as many times as
required to finish Monday's programming...

Mo * n° 05 Î 17 : 15 = Tn
modify (+/-) / yes (Î) To validate the final step for Monday (no. 05)

NEXT DAY :
Mo * n° 01 Î 07 : 00 = Tr After validating the 5th step, step no.01
next (+/-) / yes (Î) will flash again

.................. To move on to the next day (Tuesday)


Move down the steps no.01 to 07

Tu * n° 01 Î 07 : 00 = Tr Tu (Tuesday) flashes
next (+/-) / yes (Î)
NOTE : as Tuesday to Thursday will be the
same as Monday, use MENU C
(COPY WEEKDAY PROG.) : see MENU C

.................. To move on to Friday


5- OPERATION

Fr * n° 01 Î 07 : 00 = Tr Proceed as for Monday


next (+/-) / yes (Î)

Fr * n° 03 Î 11 : 30 = Tn
modify (M) / exit (Î) Press this button when weekday programming
is finished

WEEKDAY PROGRAMMING ?
yes (M) / no (Î)
To confirm programming and move on to
next menu
5- OPERATION
ª MENU C (COPY WEEKDAY PROGRAMMING)

COPY WEEKDAY PROG. ? Example : programme Tuesday as a


yes (M) / no (Î) Monday

Validate

Day to be copied Day to be programmed


(already programmed)

COPY : Su Î Su
next (+/-) / yes (Î) or Select the day to be copied

Validate

COPY : Mo Î Su
next (+/-) / yes (Î) or Select the day to be programmed

Validate

COPY : Mo Î Tu
copy (M) / no (Î) Validate the copy

NOTE : repeat this sequence to copy


COPY : Mo Î Tu
Monday onto Wednesday and Thursday.
next (+/-) / yes (Î)

To exit MENU C

COPY : Mo Î Tu
next (+/-) / yes (Î)

COPY : Mo Î Tu
copy (M) / no (Î)

COPY WEEKDAY PROG. ?


yes (M) / no (Î)
To confirm programming and move on to
next menu

In our example, the programming of Saturday and Sunday is unnecessary.


(all the steps are by default set at 00:00=Clr).
The setpoint applied is then the most recent one in operation: "Friday - 11h30 - Tn".
5- OPERATION
ª MENU D (EXCEPTIONAL DATE)

EXCEPTIONAL DATE ? NOTE : on exceptional date days, setpoint


yes (M) / no (Î) temperature / Ex alternate on display 2.
(see 5.1.3.2)

Validate

date : 01 Î 01 Jan = Clr The figure after "date" indicates the sequence
next (+/-) / yes (Î) or number of each exceptional date

Validate the sequence number

date : 01 Î 01 Jan = Clr


modify (M) / exit (Î) Validate to move on to the exceptional date.

date : 01 Î 01 Jan = Clr


modify (+/-) / yes (Î) or Select the date

Validate

date : 01 Î 01 Jan = Clr


modify (+/-) / yes (Î) or Select the month

Validate

date : 01 Î 01 Nov = Clr 4 daily programmes are available :


or Su : programming as for Sunday
modify (+/-) / yes (Î)
(normal non-working day)
Mo : programming as for Monday
(normal working day).
E1 & E2 : exceptional programmes
(see MENU F).
Clr : no programmed value, this date is
not taken into account

Validate

date : 01 Î 01 Nov = Su
next (+/-) / yes (Î) or Select exceptional date no. 02
5- OPERATION

date : 02 Î 01 Jan = Clr


next (+/-) / yes (Î)
Validate no. 02

date : 02 Î 01 Jan = Clr Proceed as for date no. 01 above


modify (M) / exit (Î)

EXCEPTIONAL DATE ?
yes (M) / no (Î)
To confirm programming and move on to
next menu
5- OPERATION
ª MENU E (EXCEPTIONAL PERIOD)

EXCEPTIONAL PERIOD ? Example : programme the period from


yes (M) / no (Î) the 4 to 10 February as a Sunday
(normal non-working day)

Validate

< 01 Jan - 01 Jan > = Clr


modify (M) / exit (Î) Validate

< 01 Jan - 01 Jan > = Clr Select the start date for the
modify (+/-) / yes (Î) or exceptional period

Validate

< 04 Jan - 01 Jan > = Clr


or Select the start month for the
modify (+/-) / yes (Î) exceptional period

Validate

< 04 Feb - 01 Jan > = Clr


Select the end date for the
modify (+/-) / yes (Î) or
exceptional period

Validate

< 04 Feb - 10 Jan > = Clr Select the end month for the
modify (+/-) / yes (Î) or exceptional period

Validate

4 daily programmes are available :


< 04 Feb - 10 Feb > = Clr Su : programming as for Sunday
modify (+/-) / yes (Î) or (normal non-working day)
Mo : programming as for Monday
(normal working day).
E1 & E2 : exceptional programmes
(see MENU F).
Clr : no programmed value, this period is
not taken into account
Validate
5- OPERATION

< 04 Feb - 10 Feb > = Su


modify (M) / exit (Î)
Validate the exceptional period

EXCEPTIONAL PERIOD ?
yes (M) / no (Î)
To confirm programming and move on to
next menu

NOTE : on exceptional period days, setpoint temperature / Ex alternate on display 2.


(see 5.1.3.2)

NOTE : where dates overlap, the exceptional period overrides exceptional dates.

ª MENU F (EXCEPTIONAL PROGRAMMES)

EXCEPT. PROGRAMME ?
yes (M) / no (Î) Validate

E1 and E2 programming is implemented


E1 ∗ n° 01 Î 00 : 00 = Clr exactly as for weekday programming.
next (+/-) / yes (Î) (see MENU B)

Validate and procced as with menu B

EXCEPT. PROGRAMME ?
yes (M) / no (Î) To confirm programming and move on to
next menu
5- OPERATION
ª MENU G (CLOCK SETTING)

CLOCK SETTING ?
yes (M) / no (Î)
Validate

Month Day
Year Date Time

00 Jan 01 Sa - 09 : 06
modify (+/-) / yes (Î) or Select the year

Validate

02 Jan 01 Tu - 09 : 06
modify (+/-) / yes (Î) or Select the month

Validate

02 Feb 01 Fr - 09 : 06
modify (+/-) / yes (Î) or Select the date

Validate

NOTE : the day is regulated automatically


as a function of the date
NOTE : procedure to follow for the summer
time to winter time change-over
02 Feb 09 Sa - 09 : 06
modify (+/-) / yes (Î) or Select the hour

Validate

02 Feb 09 Sa - 10 : 06
modify (+/-) / yes (Î) or Select the minutes

Validate
5- OPERATION

02 Feb 09 Sa - 10 : 30
save (M) / no (Î)
Save the clock setting

CLOCK SETTING ?
yes (M) / no (Î)
To confirm programming and move on to
next menu
5- OPERATION
ª MENU H (HEATING TIME)

MODULE MTH100

HEATING TIME ?
yes (M) / no (Î)
Validate

100 % = 03 h 12min 3h 12min operating time


clear (M) / exit (Î) (heaters on)

ESTIMATE OF GAS USED

Gas used =
3h12 x number of heaters
x hourly consumption of heater

Validate clear to reset the heating time


counter

CLEAR ALL ?
yes (M) / no (Î) Confirm clear

100 % = 00 h 00min
clear (M) / exit (Î) Heating time counter reset.

Exit menu H

HEATING TIME ?
yes (M) / no (Î) To confirm programming and move on to
displays
5- OPERATION
ª MENU H (HEATING TIME)

MODULE MTH150

HEATING TIME ?
yes (M) / no (Î)
Validate

100 % = 03 h 12min 3h12 of operating time on Heaters


clear (M) / exit (Î) 100% line.
alternating
50 % = 14 h 15min 14h15 of operating time on Heaters
clear (M) / exit (Î) 50% line.

ESTIMATE OF GAS USED

Total consumption =
Heaters 100% line consumption +
Heaters 50% line consumption

Heaters 100% line consumption =


3h12 x number of heaters on Heaters 100% line
x hourly consumption of one heater

Heaters 50% line consumption =


14h15 x number of heaters on Heaters 50% line
x hourly consumption of one heater

Validate clear to reset the 2 heating time


counters

CLEAR ALL ?
yes (M) / no (Î) Confirm clear

100 % = 00 h 00min
clear (M) / exit (Î)
Heating time counters reset.

50 % = 00 h 00min
clear (M) / exit (Î)

Exit menu H

HEATING TIME ?
yes (M) / no (Î) To confirm programming and move on to
displays
5- OPERATION
5.1.3.7- PRESET MODE

The module MTH controls heating according one of the three following
preset modes :

auto : follows set programming

maxi : operates in Tc mode (comfort temperature)


irrespective of day and time.

mini : operates in Tn mode (night temperature)


irrespective of day and time.

Current preset mode (REG) is indicated on display 2 :

DISPLAY 1
Th 17 Mar - 15 : 57 17.5 °C
for menu (M)

Preset mode
DISPLAY 2
Tc : 17 °C ∗ REG : auto - 100 %
modify REG ( +/- )

"Forced to on" consists in switching from "auto" mode to either the "maxi"
or "mini" mode.

This possibility can be used to change the heating control mode without
changing the programming (e.g. : heating exceptionally required on a day off)

Changing from one control mode to another


(auto Î maxi Î mini Î auto ...) can be done by :

- either pressing simultaneously on and

- or by pressing the external push-button


(if there is one)

Every day at midnight, the module MTH reset to "auto"


5- OPERATION
5.1.3.8- CUSTOMISATION

The MTH modules can display several different languages: FRENCH,


ENGLISH, GERMAN, POLISH, SPANISH and RUSSIAN.

In the same way, on the MTH150 module, the value of Delta 50% - 100%
(factory preset to 1°C) can be changed to between 1°C and 3°C inclusive,
in steps of 0.5°C.

MODULE MTH100

Displayed for 3.5 seconds when switched on :

FIRST SETTING ?
yes (M)

Before the 3.5 seconds are up To access the program

DELTA : 0,0 °C english


modify (+/-) / yes (Î) or To modify the selected language

To validate and end customisation

MODULE MTH150

Displayed for 3.5 seconds when switched on :

FIRST SETTING ?
yes (M)

Before the 3.5 seconds are up To access the program

DELTA : 1,0 °C english To modify DELTA


modify (+/-) / yes (Î) or (from 1 °C to 3 °C in 0,5 °C steps)

To validate and move on to the next value

DELTA : 1,5 °C english


modify (+/-) / yes (Î) or To modify the selected language

To validate and end customisation


5- OPERATION
5.1.3.9- SPECIAL DISPLAY FEATURES

As stated in 5.1.3.2, display can be :

BATTERY

After a few secondes, if screen is still indicating :

BATTERY The safeguard battery is empty. Contact


your SBM distributor.

If screen goes back to normal displays (1 and 2), the safeguard battery is safe.

As stated in 5.1.3.2, display 2 can be :

DISPLAY 2 MEANING

Tc = 17 ° ∗ REG : auto = 100 %


modify REG (+/-) Alternating display of current setpoint Tc
(or Tr or Tn) and Ex indicates that today's
alternating date has been programmed as an exceptional
date or period.
Ex = 17 ° ∗ REG : auto = 100 %
modify REG (+/-)

XX = 00 ° ∗ REG : auto = 100 % MENU B is not programmed


modify REG (+/-) (see MENU B)

In this configuration only "PRESET MODE"


can be accessed.

Other displays that correspond to different operating errors are possible,


see 7.1.3 or 7.2.3.

5.1.3.10- OUT-VOLTAGE SAFEGUARD OF MTH MODULES

A safeguard battery keeps date and hour in case of voltage interruption.


For keeping lifetime of battery, let the module under voltage during non-heating
season.
5- OPERATION
5.2- OPERATING DIAGRAMS

These diagrams represent the operating cycles of the modules.


They show the heating status depending on the temperature measured by the
sensor.

5.2.1- MODULES MT100 - MT100 DE - MTH100 - MTH100 DE

Heating

Ignition Re ignition
(45s) (45s)
Temperature

T° T° + 0.7°C
Setpoint
MT MTH

5.2.2- MODULES MT150 - MTH150

Heating

Re ignition
100 (45s)

Ignition Re ignition
50 + 100 50 (45s)
(45s) Temperature

T° - delta T° T° + 0.7°C
Setpoint
MT MTH
5- OPERATION
5.2.3- MODULES MT150 DE - MTH150 DE

Heating

Re ignition
100 (45s)

Ignition Re ignition
50 + 100 50 (45s)
(45s) Temperature

T° T° + T° + T° + delta
Setpoint 0.7°C delta + 0.7°C
MT MTH
5- OPERATION
5.3- SAFETY SWITCH

ª The MT and MTH modules are equipped with an output (terminals 1 and 3) for
connecting a Normally Closed dry contact.

ª This contact switches the heating off if the setting being checked develops
a defect. In this event, a flashing message is displayed on the module:

- on MT modules :

VENTILATION DEFECT
- on MTH modules : HEATING STOPPED

ª The setting being checked may be, for example :


- depression (pressure switch)
MT / MTH
- outside temperature (thermostat)
- emergency stop (switch)
- ...

Setting being checked Dry contact

ª As far as connecting to the module is concerned, see 4.7.3 and 4.7.4.

If this function is not being used, terminals 1 and 3 on the


module must be connected.

A bridge is supplied with the module for this


purpose (in the sensor plastic bag).
CERAMIC
HEATING

MAINTENANCE 6

6.1- HEATERS

6.2- ACCESSORIES

- Return to SUMMARY -
6- MAINTENANCE
6.1- HEATERS

LIST OF OPERATIONS TO BE PERFORMED DURING THE ANNUAL


MAINTENANCE VISIT :

ª Removal of dust from heaters

On site, without disassembly, heaters off and cold.

JOINTS

COMPRESSED AIR
3 to 5 bar MAX.
DO NOT AIM AT THE JOINTS
BETWEEN THE CERAMIC PLATES

ª Check condition of ceramic plates (visual inspection).

ª Check heater fixture.

ª Check heater operation.

Switch on all heaters, check ignition and combustion.


A combustion temperature of approximately 900°C (uniform orange colour)
ensures that the heater is clean and supplied with the right gas pressure.
6- MAINTENANCE
6.2- ACCESSORIES

LIST OF OPERATIONS TO BE PERFORMED DURING THE ANNUAL


MAINTENANCE VISIT :

ª Check tightness of accessories.

ª Check operation of solenoid valves.

Check that all solenoid valves properly close (heaters switched off).

ª Check controls.

ª Check all settings (do not forget anti-freeze setting) and programming
of the modules MTH100 and MTH150.
CERAMIC
HEATING

TROUBLE-SHOOTING 7

7.1- AUTOMATIC INSTALLATIONS

7.2- AUTOMATIC INSTALLATIONS (ONE SOLENOID VALVE PER HEATER)

7.3- MANUAL INSTALLATIONS

- Return to SUMMARY -
7- TROUBLE-SHOOTING
7.1- AUTOMATIC INSTALLATIONS
7.1.1- MALFUNCTIONING OF A SINGLE HEATER

First, check compatibility of heaters with the gas type and pressure.

ONE HEATER
DOES NOT LIGHT

No spark Spark

Check RP3 or RP32 Check individual valve


fuse(s) (open?)

Check gas flow throught


Check screw tightness
the injector block
of prewired plug
(«click» ?)

Check igniter :
- wire «click» No «click»
- ceramic
- distance between
earth-pin and igniter
( 5 mm )
- connection to Check cleanness of : Replace BA block and
BA block - regulator/governor (or) injector block
gas inlet filter
- heater gas inlet filter
- injector(s)

Replace BA block

ONE HEATER LIGHTS


AND GOES OUT AFTER
45 seconds

Check that
thermocouple is
properly tightened

Replace thermocouple

Replace injector block


7- TROUBLE-SHOOTING

ONE HEATER IS NOT


HOT ENOUGHT (<850°C)
(OR STUTTERING FLAME)

Check cleanness of :
- regulator/governor
inlet gas filter
- heater inlet gas filter
- injector(s)
- heater

Heater operating with Heater operating with


a fixed an adjustable
regulator/governor regulator/governor

Check injection
Replace the
pressure
regulator/governor
(see 4.8.1.4)

If adjusting i s
impossible, check
regulator/governor
inlet pressure

If regulator/governor
inlet pressure is
correct, replace
regulator/governor

ONE HEATER IS
TOO HOT (>950°C)

Heater operating with Heater operating with


a fixed an adjustable
regulator/governor regulator/governor

Check injection
Replace the
pressure
regulator/governor
(see 4.8.1.4)

If adjusting i s
impossible, replace
the regulator/governor
7- TROUBLE-SHOOTING
7.1.2- MALFUNCTIONING OF A GROUP OF HEATERS

First, check compatibility of heaters with the gas type and pressure.

A GROUP OF HEATERS
DO NOT LIGHT

No spark Spark

Control module Control module Check m ain gas


ON OFF valve (open?)

Module displays : Correct display on Check power supply Solenoid valve


VENTILATION the module Solenoid valve open
DEFECT (MTH) (m ain breaker) closed
or OFF (MT)

Check setpoint and Check gas tank or Check module


Check the electrical If m odule is
programming of the gas supply solenoid valves
continuity between supplied, replace
module pressure output voltage
terminals 1 and 2 on module
the module (230V)

Check gas flow


Check module throught the
heaters output injector blocks If no voltage,
voltage (230V) («click» ?) replace m odule
during ignition
(45 seconds)

«click» No «click»
Check fuse on
If no voltage, module solenoid
replace m odule valves output
Check cleanness of :
Replace BA blocks
- m ain gas filter
- solenoid valves
- regulators/
Check voltage at
governors gas inlet
first RP3 or RP32 Check voltage at
input filters
solenoid valve

If no voltage,
check : If solenoid valve is
- electrical cable supplied,
- connections replace it

Check RP3 and


RP32 fuse(s)

Replace BA blocks
7- TROUBLE-SHOOTING

A GROUP OF HEATERS
DO NOT STOP

Check setpoint and


programming of the
module

Check module set to


OFF :

MT = - MTH = 0%

Check zero voltage at


solenoid valve module
output

Check solenoid valve :


- orientation
- cleanness
- operation

7.1.3- MALFUNCTIONING OF CONTROL MODULE


7.1.3.1- MODULE MT

DISPLAY SHOWS
or

Reconnect sensor
and check continuity
of sensor cable

7.1.3.2- MODULE MTH

DISPLAY SHOWS
or

Reconnect sensor
and check continuity
of sensor cable
7- TROUBLE-SHOOTING
7.2- AUTOMATIC INSTALLATIONS (ONE SOLENOID VALVE PER HEATER)
7.2.1- MALFUNCTIONING OF A SINGLE HEATER

First, check compatibility of heaters with the gas type and pressure.

ONE HEATER
DOES NOT LIGHT

No spark Spark

Check thermal fuse


Check RP32 fuse s
(if there is one)

Check screw tightness Check individual valve


of prewired plug (open?)

Check igniter :
- wire Solenoid valve ON Sonenoid valve OFF
- ceramic
- distance between
earth-pin and igniter
( 5 mm )
Check solenoid valve :
- connection to - orientation Check RP32 fuse
BA block - cleanness
- operation

Replace BA block Check gas flow throught


the injector block
(«click» ?)

«click» No «click»

Check cleanness of : Replace BA block and


- regulator/governor (or) injector block
gas inlet filter
- heater gas inlet filter
- injector(s)
7- TROUBLE-SHOOTING

ONE HEATER LIGHTS ONE HEATER IS NOT


AND GOES OUT AFTER HOT ENOUGHT (<850°C)
45 seconds (OR STUTTERING FLAME)

Check that Check cleanness of :


thermocouple is - regulator/governor
properly tightened inlet gas filter
- heater inlet gas filter
- injector(s)
- heater

Replace thermocouple
Heater operating with Heater operating with
a fixed an adjustable
regulator/governor regulator/governor

Replace injector block


Check injection
Replace the
pressure
regulator/governor
(see 4.8.1.4)

If adjusting i s
impossible, check
regulator/governor
inlet pressure

If regulator/governor
inlet pressure is
correct, replace
regulator/governor

ONE HEATER IS
TOO HOT (>950°C)

Heater operating with Heater operating with


a fixed an adjustable
regulator/governor regulator/governor

Check injection
Replace the
pressure
regulator/governor
(see 4.8.1.4)

If adjusting i s
impossible, replace
the regulator/governor
7- TROUBLE-SHOOTING
7.2.2- MALFUNCTIONING OF A GROUP OF HEATERS

First, check compatibility of heaters with the gas type and pressure.

A GROUP OF HEATERS
DO NOT LIGHT

No spark Spark

Control module Control module Solenoid valves Solenoid valves


ON OFF open closed

Module displays : Correct di splay on Check module


VENTILATION Check power supply Check main gas
the module (main breaker) valve (open?) solenoid valves
DEFECT (MTH) output voltage
or OFF (MT) (230V)

Check setpoint and Check gas tank or


Check the electrical If module is
programming of the gas supply
continuity between supplied, replace
module pressure If no voltage,
terminals 1 and 2 on module
the module replace module

Check gas flow


Check module throught the
heaters output injector blocks Check voltage at
voltage (230V) («click» ?) first RP 32 input
during ignition
(45 seconds)
If no voltage,
«click» No «click» check :
- electrical cable
If no voltage, - connections
replace module
Check cleanness of :
Replace BA blocks
- main gas filter
- solenoid valves
- regulators/ Check RP32 fuse s
Check voltage at governors ga s inlet
first RP 32 input filters

If no voltage,
check :
- electrical cable
- connections

Check RP32 fuse s

Replace BA blocks
7- TROUBLE-SHOOTING

A GROUP OF HEATERS
DO NOT STOP

Check setpoint and


programming of the
module

Check module set to


OFF :

MT = - MTH = 0%

Check zero voltage at


solenoid valve module
output

Check solenoid valve :


- orientation
- cleanness
- operation

7.2.3- MALFUNCTIONING OF CONTROL MODULE


7.2.3.1- MODULE MT DE

DISPLAY SHOWS
or

Reconnect sensor
and check continuity
of sensor cable

7.2.3.2- MODULE MTH DE

DISPLAY SHOWS
or

Reconnect sensor
and check continuity
of sensor cable
7- TROUBLE-SHOOTING
7.3- MANUAL INSTALLATIONS
7.3.1- MALFUNCTIONING OF A SINGLE HEATER

First, check compatibility of heaters with the gas type and pressure.

ONE HEATER
DOES NOT LIGHT

Push-button of Push-button of
injector block injector block does
operates not operate

Check individual valve


Replace injector block
(open?)

Check cleanness of :
- regulator/governor
gas inlet filter
- heater gas inlet filter
- injector(s)

ONE HEATER IS NOT ONE HEATER LIGHTS


HOT ENOUGHT (<850°C) AND GOES OUT AFTER
(OR STUTTERING FLAME) 45 seconds

Check cleanness of : Check that


- regulator/governor thermocouple is
inlet gas filter properly tightened
- heater inlet gas filter
- injector(s)
- heater

Replace thermocouple
Heater operating with Heater operating with
a fixed an adjustable
regulator/governor regulator/governor

Replace injector block


Check injection
Replace the
pressure
regulator/governor
(see 4.8.1.4)

If adjusting i s
impossible, check
regulator/governor
inlet pressure

If regulator/governor
inlet pressure is
correct, replace
regulator/governor
7- TROUBLE-SHOOTING

ONE HEATER IS
TOO HOT (>950°C)

Heater operating with Heater operating with


a fixed an adjustable
regulator/governor regulator/governor

Check injection
Replace the
pressure
regulator/governor
(see 4.8.1.4)

If adjusting i s
impossible, replace
regulator/governor

7.3.2- MALFUNCTIONING OF A GROUP OF HEATERS

First, check compatibility of heaters with the gas type and pressure.

A GROUP OF HEATERS
DO NOT LIGHT

Check gas tank or


gas supply pre ssure

Check main gas valve


(open?)

Check cleanness of :
- main filter
- regulators/governors
gas inlet filters
CERAMIC
HEATING

SPARE PARTS 8

8.1- HEATERS

8.2- CONTROL MODULES AND ACCESSORIES

8.3- ACCESSORIES

- Return to SUMMARY -
8- SPARE PARTS
8.1- HEATERS
8.1.1- AUTOMATIC HEATERS SX AND KOMFORT
8.1.1.1- B6, B8, B10, B12, B16, B20-2, B24-2, B32-2 and B48-2

C A

H
J F

I G

For any spare part order, please specify :


- heater type and serial number
- type of gas
- operating pressure
These informations are displayed on the rating plate, attached to each heater.
8- SPARE PARTS
8.1.1.2- B20, B24, B32, B48-2 and B64-2

C A

H
E
J F

I G

For any spare part order, please specify :


- heater type and serial number
- type of gas
- operating pressure
These informations are displayed on the rating plate, attached to each heater.
8- SPARE PARTS
8.1.2- MANUAL HEATERS M
8.1.2.1- B6, B8, B10, B12 and B16

C A

For any spare part order, please specify :


- heater type and serial number
- type of gas
- operating pressure
These informations are displayed on the rating plate, attached to each heater.
8- SPARE PARTS
8.1.3- LIST OF SPARE PARTS FOR HEATERS

A BURNERS

BR 6 SX 96 For heaters B6 SX, KOMFORT and M

BR 8 SX 96 For heaters B8 SX, KOMFORT and M

For heaters B10, B20, B20-2 SX,


BR 10 SX 96 KOMFORT and B10 M
For heaters B12, B24, B24-2 SX,
BR 12 SX 96 KOMFORT and B12 M
For heaters B16, B32, B32-2, B48-2,
BR 16 SX 96 B64-2 SX, KOMFORT and B16 M

B THERMOCOUPLES

THERMOCOUPLE FA

C LOCKING SCREWS

10 LOCKING SCREW 6X100/16


(supplied by packs of 10)

D INJECTOR BLOCKS

For heaters B6, B8, B10, B12, B16, B20-2, B24-2, B32-2, B48-2
SX and KOMFORT

BLOC U-E-XXX-XXX-PP-A-12G
8- SPARE PARTS
For heaters B20, B24, B32, B48-2, B64-2 SX and KOMFORT

BLOC D-E-XXX-XXX-PP-A-12G

For heaters B6, B8, B10, B12 and B16 M

BLOC U-M-XXX-XXX-PP-A-12G

E IGNITERS

IGNITER WITH WIRE

F EARTH PINS

EARTH PIN L3-NUT


8- SPARE PARTS
G BRACKETS

BA BRACKETS (2)

H IGNITION BLOCKS

BA BLOCK

I NUTS

BA NUT

J GASKETS

10 GASKET-SCREW BA
(supplied by packs of 10)

Gasket not needed with current type of prewired plug (built-in gasket)
8- SPARE PARTS
K PREWIRED PLUGS

PREWIRED PLUG 1M/3FT

PREWIRED PLUG 3M/10FT


8- SPARE PARTS
8.2- CONTROL MODULES AND ACCESSORIES
8.2.1- LIST OF SPARE PARTS FOR CONTROL MODULES

SENSOR S4

8.2.2- LIST OF SPARE PARTS FOR RP3 AND RP32

PC BOARD RP3

PC BOARD RP32
8- SPARE PARTS
8.3- ACCESSORIES
8.3.1- LIST OF SPARE PARTS FOR ACCESSORIES

REG 1/2F I20-100 O12.5-30MBAR


For GAS SUPPLY KIT 3.3.1.35 and 3.3.1.36

Rp1/2 DN15 VALVE


For GAS SUPPLY KIT and KOMBI KIT

3.3.1.35 to 3.3.1.36

and GAS SUPPLY 3.3.1.38 to 3.3.1.40

SOL. VALVE NC 2WAY 1/2 - 1/2


For GAS SUPPLY KIT 3.3.1.35 and 3.3.1.36

and GAS SUPPLY KIT 3.3.1.39 and 3.3.1.40

COIL FOR STAIGER SOL. VALVE


For KOMBI KIT 3.3.1.38

KOMBIBLOCK 1/2F 2 SPEED


For KOMBI KIT 3.3.1.38
CERAMIC
HEATING

APPLICATIONS 9

9.1- SURVEY REQUEST

9.2- HEATING OF INDUSTRIAL AND COMMERCIAL BUILDINGS

9.3- FIXING HEIGHTS OF SBM HEATERS

9.4- SPECIFIC APPLICATIONS

9.5- ESTIMATED INSTALLATION TIME

- Return to SUMMARY -
9- APPLICATIONS
9.1- SURVEY REQUEST
9- APPLICATIONS
9- APPLICATIONS
9.2- HEATING OF INDUSTRIAL AND COMMERCIAL BUILDINGS

Typical installation

See 4.5.2.3 and 4.5.2.4

Electrical junction box with


fuse (RP3)

SBM ceramic heater

Gas connection
assembly

Solenoid valve

Sensor cable

Sensor (h=1,5 m)

Electrical cable (see 4.7.3)

Gas filter Control unit

230V - 50Hz

Main valve

To consult the various types of installation, refer to the following sections :

4.2 for SX and KOMFORT heaters


4.3 for M heaters
9- APPLICATIONS
9.3- FIXING HEIGHTS OF SBM HEATERS

For heating of industrial and commercial buildings.

9.3.1- TABLE OF COMFORT HEIGHTS

Comfort heights hi (in meters) according to heater type and inclination (I) or slope (S).
Table for SX, KOMFORT and M heaters.

Inclination I (or slope S) of heater from horizontal


Heater type
10° 15° 20° 25° 30° 35°
B6 3.6 3.5 3.5 3.5 3.4 3.3
B8 3.9 3.9 3.8 3.8 3.7 3.6
B10 4.1 4.1 4.0 3.9 3.9 3.8
B12 4.5 4.5 4.4 4.3 4.2 4.1
B16 4.9 4.9 4.8 4.7 4.6 4.4
B20 5.2 5.1 5.0 4.9 4.8 4.6
B20-2 5.2 5.1 5.0 4.9 4.8 4.6
B24 5.7 5.7 5.6 5.4 5.3 5.1
B24-2 5.7 5.7 5.6 5.4 5.3 5.1
B32 6.4 6.3 6.2 6.0 5.9 5.6
B32-2 6.4 6.3 6.2 6.0 5.9 5.6
B48-2 7.5 7.4 7.3 7.1 6.9 6.6
B64-2 8.5 8.3 8.2 7.9 7.7 7.4

I (inclination) S (slope)

hi (fixing height) hi (fixing height)


9- APPLICATIONS
9.3.2- FIXING HEIGHT FOR GROUPS OF HEATERS

In very high buildings, the heaters can be grouped together.


The fixing height of groups of heaters is given by the following formula :

 P    P  
hi =  − 0.5  × cos I + 2 or hi =  − 0.5  × cos S + 2
 540    540  

hi : fixing height in m for an inclined group of heaters


P : nominal heat input of the group of heaters in W (Hi)
cos I : cosine of the angle of inclination in degrees (35° max.)
cos S : cosine of the angle of slope in degrees (35° max.)

I (inclination) S (slope)

hi (fixing height) hi (fixing height)

Example :

For a group of 3 B64-2SX with a slope of 10°, their fixing height is :

 P  
hi =  − 0.5  × cos S + 2
 540  

The nominal heat input of a B64-2SX heater is 27 kW


⇒ P = 3 x 27000 = 81000 W

 81000  
⇒ hi =  − 0.5  × cos 10° + 2
 540  

⇒ hi = 13.60 m
9- APPLICATIONS
9.4- SPECIFIC APPLICATIONS

9.4.1- HEATING OF WORK STATIONS (Permanent equipment)

Each work station must be heated by means of two ceramic heaters, one on each side
and placed at an angle of 30°.

e e

hi
30°

The selection of the heater type and horizontal distance (distance heater - work station) e
dependends on the fixing height hi :

B6 B8 B10 B12 B16 B20 B24 B32 B48 B64


hi (m) 2.70 3.00 3.15 3.50 4.00 4.10 4.60 5.20 6.20 7.00
e (m) 1.60 1.70 1.80 2.00 2.30 2.40 2.70 3.00 3.60 4.00

hi (fixing height in m) is calculated as follows :

 P  
hi =  − 0.5  × cos 30° + 1.3
 540  

P : nominal heat input of the heater or group of heaters in W (Hi)


cos 30° = 0.866.

e (horizontal distance heater - work station in m) is calculated as follows :

e = hi tan 30°

tan 30° = 0.577

THIS DOCUMENT IS ONLY APPLICABLE IN THE CASE OF A PROTECTED


ENVIRONMENT.
9- APPLICATIONS
9.4.2- TERRACE HEATING (Permanent equipment)

Gas infrared heaters for terrace heating :


ª Application :
- open terraces.
- or with permanent openings : minimum area 25% of area of the largest
outside surface (natural ventilation)
- or with mechanical ventilation (fans) : at least 10 m3/h per kW operating.
Note : Infrared heating operates on the same principle as the sun (without the
risk of sun-burn), a person receiving sun rays remains sensitive to the wind.

ª Heating computation (in the lack of information, select 800 W/m²) :

For terrace heating, no temperature guarantee is provided.

Capacity : 0,5 to 1 kW/m2 (Net Calorific Value)


- Base capacity :
500 W/m2 of floor area for a terrace in optimal conditions (closed with
minimum required ventilation + winter >0°C + insulated floor (for example
wooden deck) + wind protection + altitude < 600m above sea level).
- Additional capacity (in addition to the 500 W/m2) :
Add the following capacity if the corresponding condition is fulfilled :
a) Floor not insulated +100 W/m2
b) Strong wind +100 W/m2
c) Winter outside temperature <0°C +100 W/m2
d) Open terrace +100 W/m2
e) Altitude > 600m above sea level +100 W/m2
9- APPLICATIONS
Installation type

Gas inlet assembly


(Valve, regulator…)
Solenoïd valve

0,50 m

RP3

Sensor
Sensor cable
2,2 minimun

Control unit Depth: P

Gas filter

Main gas valve

ª Installation height :

Heathers SX - CE Capacity (kW)* H mini (m) H recommended (m)


B8 SX 3.30 2.20 2.20
B10 SX 3.80 2.20 2.40
B12 SX 5.10 2.50 2.80
B16 SX 6.75 2.50 3.20
B20 SX 7.60 2.50 3.50
B24 SX 10.20 3.00 4.00
B32 SX 13.50 3.50 4.60
* Based on net calorific value of gas.

Minimum distance between the heaters and roof or awning = 0.50 m.


9- APPLICATIONS
ª Depth of terrace P heated :

P (refer to the drawing previous page) : depth at the floor level.

The depth P is function of the heaters fixing height H and angle of inclination i
(between 20 and 40°).

• If i between 20 and 25°: P = 0.7 x H


• If i between 25 and 30°: P = 0.8 x H H i
• If i between 30 and 35°: P = 0.9 x H
• If i between 35 and 40°: P=H

P
- Heaters hanged with a small inclination (10 to 15°):

Always install the heaters with 10° minimum inclination. In such case the floor
area heated is a square area 2H x 2H.

2H
The heater is in the centre of the heated area :

2H
ª Minimum safety requirement :

- Minimum safety distances from non protected inflammable materials :


• 0.50 m upwards, (0.30 m with heat protection)
Example of heat protection: metal deflector made of 1 mm aluminium
plate.
• 0.60 m laterally
• 1.00 m downwards.

- The heaters and gas lines must not be used as fixing points.

- Every heater must be equipped with an individual gas valve (manual).

- Each terrace installation must include a main gas valve (manual), easily
accessible for shutting off all heaters.

- Installation must be carried out by a PROFESSIONAL INSTALLER.

- All local regulations must be strictly followed.


9- APPLICATIONS
ª Example of sizing :
Use the SBM terrace check-list (see next page).
A Length in m 12 Terrace Type 1
P1 Depth in m 3
P2 Width in m -
C Maximum height in m 3.7
D Minimum height in m 2.5
H Heaters Fixing height in m
3
(if H wished / always >2.2 m) C D
H
Insulated floor (wooden deck or equivalent) YES / NO No
Wind protection: YES / NO Yes A
Minimum outside T°C for use of terrace: >0°C or <0°C >0°C P1
Terrace (Open / Closed), (if closed, size of pemament
O
exhaust openings for ventilation in m²)
Altitude above sea level: <600 m or >600 m <600m

1) Base capacity : 500 W/m2 minimum

2) Additional capacity (in addition to the 500 W/m2 above) :

• Floor not insulated yes +100 W/m2


• Strong wind yes +100 W/m2
• Winter outside temperature <0°C no NA
• Open terrace yes +100 W/m2
• Altitude > 600m above sea level no NA

C/m2 = 500+100+100+0+100+0 = 800 W/m2 = 0.8 kW/m2


S = 12 x 3 = 36 m2
C totale = 36 x 0.8 = 28.8 KW/h
H=3m B12SX (Hi = 5.10 KW/h)
P / 5.10 = 5.6 rounded 6 B12 SX

Spacing from last heater to end of terrace = 1.5 m


Spacing between other heaters = 1.8 m

1.5m 1.8m 1.8m 1.8m 1.8m 1.8m 1.5m

Inclination = 35°, therefore P = H = 3 m

Heaters SX - CE Capacity (kW)* H mini (m) H recommanded (m)


B8 SX 3.30 2.20 2.20
B10 SX 3.80 2.20 2.40
B12 SX 5.10 2.50 2.80
B16 SX 6.75 2.50 3.20
B20 SX 7.60 2,50 3.50
B24 SX 10.20 3.00 4.00
B32 SX 13.50 3.50 4.60
*Based on net calorific value of gas.
9- APPLICATIONS
ª Check-list terrace :
9- APPLICATIONS
9.5- ESTIMATED INSTALLATION TIME

The installation times listed below are for guidelines only. SBM shall not be liable
in case the following figures are exceeded for a specific job.

Installation Installation
Equipment Equipment
time (h) time (h)
Heaters Electrical wiring *
B6 to B16 1.50 Electrical cable 3x1.5 mm2
0.25 / m
B20 to B32 1.80 (for MT100 and MTH100)
B20-2, B24-2, B32-2 2.00 Electrical cable 5x1.5 mm2
B48-2 2.40 0.25 / m
(for MT150 and MTH150)
B64-2 2.80 Sensor cable 0.25 / m
Group of 2 B64-2 4.50
Group of 3 B64-2 6.10
Electrical accessories
Group of 4 B64-2 8.20 Control panel 4.00
Gas accessories Heater bracket
Gas valve 1.00 B6 to B32-2 0.30
Gas filter 1.00 B48-2 and B64-2 0.50
Solenoid valve 1.00 Group of 2 B64-2 0.80
Group of 3 B64-2 1.20
Copper gas piping Group of 4 B64-2 1.60
Copper 10x12 0.46 / m
Copper 12x14 0.48 / m
Copper 14x16 0.50 / m
Copper 16x18 0.50 / m
Copper 20x22 0.60 / m
Steel gas piping
Steel nominal bore 15 0.50 / m
Steel nominal bore 20 0.85 / m
Steel nominal bore 25 0.90 / m
Steel nominal bore 32 0.95 / m
Steel nominal bore 40 1.05 / m
Steel nominal bore 50 1.10 / m
Steel nominal bore 65 1.30 / m
Steel nominal bore 80 1.40 / m
Steel nominal bore 100 1.50 / m

* MT100 or MTH100 :
Length of electrical cable 3x1.5 mm2 = length of gas piping
+ length of cable necessary to connect the solenoid valves.

MT150 or MTH150 :
Length of electrical cable 5x1.5 mm2 = length of gas piping
Length of electrical cable 3x1.5 mm2 = length of cable necessary to connect
the solenoid valves.
CERAMIC
HEATING

TECHNICAL NOTES 10

10.1- UNITS CONVERSION TABLE

10.2- WITHDRAWAL RATES FOR VARIOUS GAS CONTAINERS

10.3- DEFINITIONS

10.4- USE OF THE UNION FITTING R1/2m-G1/2m

- Return to SUMMARY -
10- TECHNICAL NOTES
10.1- UNITS CONVERSION TABLE

LENGTH

m in ft yd
1m 1 39.37 3.2808 1.0936
1 in 0.0254 1 0.0833 0.0278
1 ft 0.3048 12 1 0.3333
1 yd 0.9144 36 3 1

AREA

m2 sq in sq ft sq yd
1 m2 1 1550 10.764 1.1960
1 sq in 0.64516x10-3 1 0.00694 0.772 x10-3
1 sq ft 0.0929 144 1 0.1111
1 sq yd 0.8360 1296 9 1

VENTILATION

m3/h m3/s CFM


1 m3/h 1 2.777 x10-4 0.625
1 m3/s 3600 1 2250
1 CFM 1.6 4.444 x10-4 1

TEMPERATURE

°F °C °K
(1.8 x t°C) + 32 (t°F -32) / 1.8 t°C + 273

HEAT LOSS

K (W x m2 x °C) (metric) R (°F / Btu x ft2 x h) (USA)


1 1
0.1761 x R (USA) 0.1761 x K (metric)
10- TECHNICAL NOTES

ENERGY

joule kWh th Kcal B.t.u.


-7 -7 -4
joule 1 2.78 x 10 2.39 x 10 2.39 x 10 9.48 x 10-4
kWh 3.60 x 106 1 0.86 860 3.414 x 103
th 4.18 x 106 1.163 1 1000 3.97 x 103
Kcal 4.18 x 103 1.163 x 10 -3
1 x10-3 1 3.968
B.t.u. 1.05 x 103 2.93 x 10-4 2.52 x 10-4 0.252 1

PRESSURE

Pa bar mbar atm. mmH2O mmHg P.S.I.


-5 -2 -5 -2
Pa 1 10 10 0.99 x 10 0.10 0.75 x 10 1.45 x 10-4
5
bar 10 1 103 0.987 1.02 x 10 4
750 14.50
2 -3 -3
mbar 10 1 x 10 1 0.98 x 10 10.2 0.75 1.45 x 10-2
atm. 1.01 x 105 1.013 1.013 x 103 1 1.03 x 104 760 14.70
mm H2O 9.81 0.98 x 10-4 9.81 0.97 x 10 -4
1 0.073 1.42 x 10-3
-3 -3
mm Hg 133.3 1.33 x 10 1.333 1.32 x 10 13.59 1 1.9 x 10-2
3 -2 -2
P.S.I. 6.89 x 10 6.89 x 10 68.9 6.8 x 10 703 51.71 1

MULTIPLES

Factor Designation Symbol Multiply by


12
10 tera T 1 000 000 000 000
109 giga G 1 000 000 000
106 mega M 1 000 000
103 kilo k 1 000
102 hecto h 100
101 deca da 10
10-1 deci d 0.1
10-2 centi c 0.01
10-3 milli m 0.001
10-6 micro µ 0.000 001
10-9 nano n 0.000 000 001
10-12 pico p 0.000 000 000 001
10- TECHNICAL NOTES
10.2- WITHDRAWAL RATES FOR VARIOUS GAS CONTAINERS

10.2.1- WITHDRAWAL RATES FOR ONE 35 kg PROPANE GAS BOTTLE (in g/h)

Loading time
Outside
temperature Permanent
1/2 hour 1 hour 2 hours
loading
- 15°C 1200 950 750 450
- 5°C 1800 1500 1200 550
+ 5°C 2500 1900 1600 700
+ 15°C 3200 2400 1900 900

10.2.2- WITHDRAWAL RATES FOR ONE PROPANE GAS TANK (in kg/h)

Tank capacity Outside temperature


(in ton) - 5°C - 10°C - 15°C - 20°C - 25°C
0.5 3.5 2.5 1.6 0.5 -
1 6.5 5 2.9 0.9 -
1.75 12 8 5 1.6 -
3.5 18 13 8 2.2 -
7 23 17 10 3 -
10 30 22 13 4 -

Basis for the calculation :

ƒ Minimum pressure at tank outlet : 1.5 bar


ƒ Tank filled at 25 %
ƒ Wind speed : 2.5 m/s

Values are given for information only, with no SBM liability involved
(confirmation to be given by the propane supplier).
10- TECHNICAL NOTES
10.3- DEFINITIONS

10.3.1- CALORIFIC VALUE

10.3.1.1- NET CALORIFIC VALUE

The quantity of heat produced by the combustion of unit volume or mass


of dry gas at constant pressure, the combustion products being brought
to 15°C but supposed to contain the combustion water in the vapour
state, and the air required for combustion being considered as previously
dry at 15°C, and the gas being dry at a temperature of 15°C and a
pressure of 1013.25 mbar.

It is expressed in megajoules either per m3 of dry gas measured at 15°C


and a pressure of 1013.25 mbar, or per kg of dry gas.

Symbol : Hi

10.3.1.2- GROSS CALORIFIC VALUE

The quantity of heat produced by the combustion at constant pressure of


unit volume or mass of gas considered, the combustion water being
condensed and the reference conditions being the same as for the net
calorific value.

It is expressed in megajoules either per m3 of dry gas measured at 15°C


and a pressure of 1013.25 mbar, or per kg of dry gas.

Symbol : Hs
10- TECHNICAL NOTES
10.4- USE OF THE UNION FITTING R1/2m-G1/2m

!
Rp1/2" R1/2" G1/2"
(ISO 7/1) (ISO 7/1) (ISO 228/1)

G1/2"
(ISO 228/1)

Gas tightness by supplied washer.

Ensure gas tightness between


component using a certified product !