Sie sind auf Seite 1von 16

Flexible and

safe solutions,
for decades.

Cables for alarm-


and safety systems
e o ffe r th e w id est range
W
c a b le s o n th e m arket for
of
k in d o f in s ta ll a tion.
every

2
It´s all about
reliability.
It is always important to choose high quality cables,
especially when it comes to alarms and safety systems.
Even small and seemingly insignificant details can
make a big difference in terms of ease of handling,
functionality and service life.

We have the cables you are looking for

We offer the widest range of cables on the market for


every kind of installation. The cables we supply carry
signals and power supplies. For extra peace of mind
concerning fire protection, our cables are available in
versions meeting specified fire safety requirements in
installations.

Halogen free for greater safety

We have decided only to include halogen free cables


in this brochure. There is a clear trend in that direc-
tion, and there is no longer any reason for not choo-
sing halogen free cables. Halogen free cables offer
many advantages – in particular, they make it easier
to escape the building in the event of fire, generating
substantial savings in the long run.

100 years of experience thrown in

At Nexans we research, develop and manufacture


cables for the whole world. For different environments
and climates. And we’ve been doing it for more than
a hundred years. So when you choose our cables,
they come with a whole lot more – our dedication and
all the experience and expertise we’ve built up over
the decades.

3
Product segments
Video surveillance Fire alarms
(CCTV) Detector networks often occupy

Locally installed CCTV (closed large volumes so cables must be

circuit TV) systems are increasingly easy to install. Nexans cables are

being used as a crime prevention easy to strip and are optimised

tool. to simplify installation in pipes.


Choose from simple, non twisted
In addition to standardized coaxial pair cables for small conventional
cable, Nexans also supplies cables systems and twisted pair cables
with separate power supply and a for larger addressable systems.
data cable for IP based solutions The cables used in fire alarm
outdoor. detector networks should normally
have a red sheath. If the cables
are required to keep working
during a fire, you should use
Nexans Alsecure® (see page 12
”Performance during a fire”).

4
Performance Access protection
during a fire Burglar alarms usually have a sys-
There is a separate fire class tem of control units and sensors.
for cables that are required to Indoor and outdoor entry systems
maintain sircuit integrity during a contain card readers, central units
fire. These cables all have unique and computers. The cables used
insulation material that is not for intruder protection and entry
damaged like normal cables. This control are signal cables with vary-
category can include power supply ing flexibility, shielding and cores.
cables as well as signal cables. Alternatively, combination cables
They should also be flame retar- can be used with separate cores
dant low fire hazard cables – in carrying the power supply.
other words they must not give off Nexans’ wide range makes it easy
any toxic or corrosive gases, and to choose the right cables for the
only small amounts of smoke, if various components.
there is a fire.

The Nexans cables for these appli-


cations are called Alsecure®. The
unique insulation (INFIT™) makes
the cables easy to install while
ensuring they still work during a
fire.

5
Video surveillance (CCTV)
CCTV (Closed Circuit TeleVision) is a locally installed
video surveillance system. A CCTV system consists of
cameras, monitors, transmission elements (cables),
RG 59 LSZH
control systems and storage systems. Our range of
halogen free cables for CCTV includes 75 ohm coaxial Coaxial cable for video surveillance. The impedance of the
cable. We also offer a combined coax and power cable: 75 ohm.

supply cable to optimise functionality as well as cable Cable Nexans no. Outer diam. Length

laying. RG 59 LSZH 19502641 6,1 mm Bobbin/100


RG 59 LSZH 19502671 6,1 mm Bobbin/500

RG 59 LSZH + 2 x 0,75 mm2


Combined coaxial (75 ohm) and power supply cable (max.
100V) for video surveillance.

Cable Nexans no. Outer diam. Length

RG 59 LSZH + 2 x 0,75 mm2 19503098 9,5 mm Drum/500

For added safety, video


sur-
veillance cables are also
flame
retardant and halogen fr
ee.

6
S/FTP Category 6A LSZH + PE
Category 6A, 500 MHz Screened data cable. The 4 pairs are
individually foiled and covered with a common braid. Due
to the outer sheath of PE the cable is appropriate for outdoor
installation as well as in exposed areas. It can be installed
indoors when the PE sheet is removed. The cable fulfills cat

LANmark Industry outlet IP67 6A performance according to EN 50288, IEC 61156 and TIA
568-B
The LANmark Industry outlet enables the installation of data
Cable Nexans no Outer diam. Length
outlets in exposed areas as well as outdoor solutions. The
Category 6A 4x2x0,5 39020771 8,6 B/500
IP67 level of protection is maintained both when the outlet
is nused and when the appropriate IP67 patchcords are
connected. Includes 2 screened category 6 or category 6A
connectors.
Cable Nexans no

IP67 outer with RJ45 cat.6 shielded Snap-in connector, black. 40060109
IP67 outer with RJ45 cat.6A shielded Snap-in connector, black. 40061009
IP67-IP20 cabling 1,5 m shielded, yellow. Cat.6 RJ45. 40060209
IP67-IP20 cabling 3 m shielded, yellow. Cat.6 RJ45. 40060309
IP67-IP20 cabling 5 m shielded, yellow. Cat.6 RJ45. 40060409

7
Find out more
about fire safety
and fire classes.

8
You often won’t know whether you
chose the right cable until after a fire.
People always talk about fire protection but it is important to know what this actually
means in practical terms, and to be certain which flame spread rating you need to
use. For cables, you also need to distinguish between flame spread, fire hazard pro-
perties and fire resistance.

Cables that prevent flame spread

Cables running through building levels and walls are a great way for fires to spread.
So the most important requirement when establishing fire protection is to use cables
with properties that prevent the spread of fire. This is why there are general flame
spread classes, and these must always be defined. Our cables have clearly marked
flame spread classes that are informative and easy to understand.

Halogen free – saving lives and money

Smoke and gases from burning cables often cause the biggest problems for people
and equipment. These problems can be reduced if halogen free cables are used. The
smoke from halogen free cables during a fire is much thinner and does not corrode
metals. This makes it easier to clear smoke from rooms, potentially saving lives. That
is why our cables for alarms and safety systems are halogen free.

Still working during a fire

The most critical cables must also be fire resistant. This means they must be guaran-
teed to work even during a fire. This is made possible by special insulation material,
which is merely altered rather than destroyed by fire. The cable keeps its shape, the
conductors are kept separate and the cable continues to work. These cables are
needed for the fire alarm system itself, but also for the safety lighting guiding people
out of the building, for the smoke extraction fans and for the lifts. Our range includes
fire resistant cables for power supply and for communication.

9
Fire alarms
Nexans has a full range of cables for fire alarm systems

The right cable for the right use

Cables for fire alarms are available with either red or ELQRB
grey sheaths depending on the regulations, aesthe- Signal cable for fire alarms. ELQRB construction is as speci-
tic requirements, etc. In larger addressable systems, fied in SS 424 16 09.
twisted pair cable should be used, KLM-LSZH 2x1.0 Cable Nexans no. Outer diam. Length
mm. If shielded cable is required, Nexans supplies the ELQRB 2 x 0,6 mm 18641541 2,9 x 4,2 mm Bobbin/100
KLMA LSZH. If the cables are required to keep working ELQRB 2 x 0,6 mm 18641571 2,9 x 4,2 mm Bobbin/500

during a fire, fire resistant Alsecure cables are used. ELQRB 2 x 1,0 mm 18641641 3,3 x 4,9 mm Bobbin/100
ELQRB 2 x 1,0 mm 18641671 3,3 x 4,9 mm Bobbin/500
Installation ELQRB 4 x 1,0 mm 18641971 5,7 mm Bobbin/500

The cables for fire alarms are intended for permanent


indoor installation.

KLM LSZH
Halogen free signal cable. The cable construction is, where
applicable, as specified in SFS 2751.
Cable Nexans no. Outer diam. Length

KLM LSZH 2x0,8 37156243 4,0 mm Coil/150


KLM LSZH 2x0,8 37156258 4,0 mm Bobbin/600
KLM LSZH 4x0,8 37156443 5,0 mm Coil/150
KLM LSZH 4x0,8 37156458 5,0 mm Bobbin/600

KLM LSZH 2x1,0


Halogen free, pair-twisted signal cable. The cable construc-
tion is as specified in SS 424 16 54 (ELQYB).
Cable Nexans no. Outer diam. Length

KLM LSZH 2x1,0 37159271 5,7 mm Bobbin/500

KLMA LSZH
Halogen free, pair-twisted signal cable. The cable construc-
tion is as specified in SS 424 16 54 (ELQYB).
Cable Nexans no. Outer diam. Length

KLMA LSZH 2x0,8 37158243 5,0 mm Coil/150


KLMA LSZH 2x0,8 37158258 5,0 mm Bobbin/600
KLMA LSZH 4x0,8 37158443 5,5 mm Coil/150
KLMA LSZH 4x0,8 37158458 5,5 mm Bobbin/600

10
Fire resistant cables
maintain circuit integrity
even when affected
by heat or flames.

11
Performance during a fire
Fire resistant cables are recommended for use in instal- Installation
lations that must maintain circuit integrity during a fire.
Examples of systems that must maintain circuit integrity
Using these cables in important alarm, control, signal
during a fire include signal and safety systems guiding
and power supply systems means you can guarantee
people out of the building. Other examples are smoke
they will not be taken down, even if the fire reaches the
extraction fans and lifts. Fire alarm cables, too, if they
cables themselves.
pass through areas that are not monitored by detec-
No gases, little smoke tors, are required to maintain circuit integrity during a
fire.
As well as continuing to work during and after a fire,
Nexans fire resistant cables are halogen free so they do
not release any toxic or corrosive gases, and only small
amounts of smoke, if there is a fire. Studies show that
this can save lives and money.

ALSECURE® PLUS 0,6/1kV, FRHF ALSECURE® PLUS TEL, skärmad


Fire resistant power cable with round or sector shaped, stran- Fire resistant, twisted pair, shielded telecom and signal cables
ded, soldered copper conductor and concentric shielding. for permanent installation indoors or in pipes. Fire perfor-
For permanent installation in all areas. Fire performance mance according to IEC60331, IEC 60332-3.
according to IEC 60331, IEC 60332-3. Cable Nexans Outer Length
no. diam.
Cable Nexans no. Outer diam. Length
Alsecure Plus Tel 1 x 2 x 0,9 mm 17541198 6,7 mm Drum/500
Alsecure Plus 1kV 2 x 1,5/1,5 27005698 11,9 mm Drum/500
Alsecure Plus Tel 2 x 2 x 0,9 mm 17541298 7,4 mm Drum/500
Alsecure Plus 1kV 3 x 1,5/1,5 27004498 12,5 mm Drum/500
Alsecure Plus Tel 10 x 2 x 0,9 mm 17541698 16 mm Drum/500
Alsecure Plus 1kV 4 x 1,5/1,5 27005798 15,2 mm Drum/500
Alsecure Plus Tel 2 x 1,5 mm +1,5 mm 17544141
2 2
8,0 mm Bobbin/100
Alsecure Plus 1kV 2 x 2,5/2,5 27005898 14,7 mm Drum/500
Alsecure Plus 1kV 3 x 2,5/2,5 27005998 15,2 mm Drum/500
Alsecure Plus 1kV 4 x 2,5/2,5 27030198 16,4 mm Drum/500
Alsecure Plus 1kV 4 x 6/6 35123998 18,1 mm Drum/500
Alsecure Plus 1kV 4 x 10/10 35124198 22,0 mm Drum/500
Alsecure Plus 1kV 4 x 16/16 35124398 24,2 mm Drum/500 ALSECURE® PREMIUM
Alsecure Plus 1kV 4 x 25/16 35124598 26,0 mm Drum/500
Fire resistant, twisted pair, fire alarm cables for permanent
Alsecure Plus 1kV 4 x 35/16 35124798 30,0 mm Drum/500
installation indoors or in pipes. Fire performance according
Alsecure Plus 1kV 4 x 50/25 35126598 35,0 mm Drum/500
to IEC60331, IEC 60332-3.
Alsecure Plus 1kV 4 x 70/35 35125198 36,0 mm Drum/500
Cable Nexans Outer Length
Alsecure Plus 1kV 4 x 95/50 35125398 41,0 mm Drum/500 no. diam.

Alsecure Plus 1kV 4 x 120/70 35125598 42,2 mm Drum/500 Alsecure Premium 2 x 1,0 mm 17542171 6,2 mm Bobbin/500

Alsecure Plus 1kV 4 x 150/70 35125798 49,0 mm Drum/500 Alsecure Premium 10 x 2 x 1,0 mm 17542698 17,0 mm Drum/500

Alsecure Plus 1kV 4 x 185/95 35125898 52,0 mm Drum/500


Alsecure Plus 1kV 4 x 240/120 35126198 60,0 mm Drum/500

12
ALSECURE® PLUS STYR 300/500V ALSECURE® PREMIUM 300/500V
Fire resistant, halogen free, unshielded installation cables Fire resistant, halogen free control cables with round, solid
with round, solid copper conductors. For permanent installa- copper conductors. This cable is designed for permanent
tion on cable ladders, directly on walls or in pipes or ducting. installation on cable ladders, directly on walls or in pipes or
Fire performance according to IEC60331, IEC 60332-3. ducting. Applications include emergency lighting, fire alarm
systems and control systems. Fire performance according to
Cable Nesans no. Outer diam. Length

Alsecure Plus Styr 7G1,5 27001498 14 mm Drum/500


IEC60331, IEC 60332-3.
Cable Nexans no. Outer diam. Length
Alsecure Plus Styr 12G1,5 27001198 19,5 mm Drum/500
Alsecure Premium 3G1,5 27010098 8,0 mm Drum/500
Alsecure Plus Styr 19G1,5 27004198 22,5 mm Drum/500
Alsecure Premium 3G2,5 27010198 10,0 mm Drum/500
Alsecure Plus Styr 7G2,5 27008298 16 mm Drum/500
Alsecure Premium 4G1,5 27010298 9,5 mm Drum/500
Alsecure Premium 5G1,5 27010398 10,0 mm Drum/500
Alsecure Premium 5G2,5 27010598 12,0 mm Drum/500

Another importan
t fire
safety property is
low
smoke developme
nt.

13
Access protection
Our cables for intruder alarms and entry systems
come in a range of types. We have shielded as well as
unshielded twisted pair cables – up to ten pairs. We
ELQXB (halogen free EKKX)
also offer flexible single wire cables with four to 12
cores. Combination cables are also available for entry Twisted pair cable for intruder alarms and entry systems.
systems – cables with twisted pair signal elements and Cable Nexans no. Outer diam. Length

power supply elements (max 100 V). ELQXB 1 x 4 x 0,5 mm 17501041 3,4 mm Bobbin/100
ELQXB 1 x 4 x 0,5 mm 17501071 3,4 mm Bobbin/500
ELQXB 2 x 2 x 0,5 mm 17500241 4,5 mm Bobbin/100
ELQXB 2 x 2 x 0,5 mm 17500271 4,5 mm Bobbin/500
ELQXB 4 x 2 x 0,5 mm 17501141 5,3 mm Bobbin/100
ELQXB 4 x 2 x 0,5 mm 17501171 5,3 mm Bobbin/500
ELQXB 6 x 2 x 0,5 mm 17501241 6,0 mm Bobbin/100
ELQXB 6 x 2 x 0,5 mm 17501271 6,0 mm Bobbin/500
ELQXB 10 x 2 x 0,5 mm 17501341 7,5 mm Bobbin/100
ELQXB 10 x 2 x 0,5 mm 17501371 7,5 mm Bobbin/500

FQQXB
Flexible signal and alarm cables for intruder alarms and
access control systems.
Cable Nexans no. Outer diam. Length

FQQXB 4 x 0,22 mm2 17523141 3,7 mm Bobbin/100


FQQXB 4 x 0,22 mm2 17523171 3,7 mm Bobbin/500
FQQXB 6 x 0,22 mm2 17523241 4,2 mm Bobbin/100 MHS LSZH
FQQXB 6 x 0,22 mm2 17523271 4,2 mm Bobbin/500
Pair-twisted, shielded communication cable with halogen
FQQXB 8 x 0,22 mm2 17523341 4,7 mm Bobbin/100
free, flame retardant sheath. The cable construction is, where
FQQXB 8 x 0,22 mm2 17523371 4,7 mm Bobbin/500
applicable, as specified in SFS 5739.
FQQXB 12 x 0,22 mm2 17523441 5,4 mm Bobbin/100
FQQXB 12 x 0,22 mm2 17523471 5,4 mm Bobbin/500 Cable Nexans no. Outer diam. Length

FQQXB 4 x 2 x 0,22 mm 2
17524271 5,3 mm Bobbin/500 MHS LSZH 1x4x0,5 38565040 5,0 Coil/100

FQQXB 10 x 2 x 0,22 mm2 17524898 8,0 mm Drum/500 MHS LSZH 1x4x0,5 38565098 5,0 Drum/1000
MHS LSZH 3x2x0,5 38565145 6,0 Coil/200
MHS LSZH 3x2x0,5 38565198 6,0 Drum/1000
MHS LSZH 5x2x0,5 38565243 6,5 Coil/150
MHS LSZH 5x2x0,5 38565298 6,5 Drum/1000
MHS LSZH 10x2x0,5 38565340 8,5 Coil/100
MHS LSZH 10x2x0,5 38565398 8,5 Drum/1000

14
FLQQBR FLAQQBR
Combined power supply and signal cables for intruder Combined power supply and signal cables for intruder
alarms and entry systems. The twisted pair signal element is alarms and entry systems. The twisted pair signal element is
unshielded. unshielded.
Cable Nexans Outer Length Cable Nexans Outer Length
no. diam. no. diam.

FLQQBR 2 x 1,5 + 2 x 2 x 0,5 mm2 17513198 8,5 mm Drum/500 FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17033341 6,5 mm Bobbin/100
FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm 2
17513041 6,5 mm Bobbin/100 FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm 17033371
2
6,5 mm Bobbin/500
FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17513071 6,5 mm Bobbin/500 FLAQQBR 2 x 1,0 + 2 x 2 x 0,22 mm2 17515198 8,0 mm Drum/500
FLQQBR 2 x 1,0 + 2 x 2 x 0,22 mm2 17513271 7,5 mm Bobbin/500 FLAQQBR 3 x 1,0 + 2 x 2 x 0,6 mm 17034298 8,5 mm Drum/500

th e e x act
We have complies
at
cable th needs.
ur
to all yo

15
Our cables for alarm- and
safety
systems compared with othe
rs.

Learn more about what significates our cables


for alarm- and safety systems at www.nexans.se

Nexans Sweden AB, 514 81 Grimsås, www.nexans.se

Das könnte Ihnen auch gefallen