The flexible office system 1 TOP RETURN SYSTEM shown in a typical operating scenario FULL COOLING MODE
return air sensor
independent
controller
raised
modular
floor
Drawing on over 40 years
market leading industry
experience and with a
of the future
Uplighter Zone Unit
pedigree in manufacturing
If the room is too warm, the LECU senses that
and engineering, Denco
the return air is warmer than the chosen set
Air Conditioning is ready
temperature. The damper is modulated open heater
(opt) to face the challenges of
to allow sufficient conditioned air from the floor
WHY USE THE DENCO FLEXIBLE OFFICE SYSTEM? void to meet the requirements of the heat load.
fan fully modulating
damper
floor void
sensor
the new Millennium.
The inflexibility of ceiling mounted air The Denco Flexible Office System can cost With an open, flexible
conditioning and lighting, together with wall effectively alleviate these problems and, approach and a strong
mounted telephone, power and data sockets furthermore, when applied to new builds, can focus on customer
severely increase the cost and disruption when offer major reductions in both construction - hot zone - - ambient zone - - cool zone - RE-CIRCULATION MODE return air sensor raised
modular satisfaction, you can rely
requires cooling ventilation only requires heating floor
independent
reconfiguring the traditional office space. times and building costs. controller on Denco to offer a
LECU fan tile
When a LECU senses that local air matches solution no matter how
the chosen set temperature, the damper is big the problem.
THE FLEXIBLE OFFICE CONCEPT closed, re-circulating the local air. The LECU
allows a portion of the underfloor conditioned
2
heater
In its ultimate form, quick and easy relocation Denco Flexible Office Air Conditioning System,
CEILING RETURN SYSTEM shown in a typical operating scenario (opt)
air to be circulated to the room at all times,
of all electrical items is achieved with the use obviates the need for a suspended ceiling. All ensuring a sufficient supply of fresh air.
fan fully modulating
damper
floor void
sensor
of a dedicated system of power and data services are now conveniently accessible in
tracks run in a raised modular floor void. the floor void allowing easy reconfiguration
Combining the use of uplighters with the and maintenance.
LOCAL HEATING MODE return air sensor raised
modular
independent floor
controller
THE DENCO FLEXIBLE OFFICE AIR CONDITIONING SYSTEM
When a LECU senses that the local area is
The Denco Flexible Office Air Conditioning intelligent fan tiles, replacing 600 x 600 mm
too cold; the damper modulates closed and
System is available in 3 basic configurations floor panels, and requiring only 240V supply to
if necessary the optional electric heater is heater
(shown opposite), but each utilises the raised operate, provide truly personal environmental (opt)
activated until the zone unit provides general
modular floor to distribute conditioned and control for the occupants. Fan tiles can be - hot zone -
requires cooling
- ambient zone -
ventilation only
- cool zone -
requires heating
heating to the floor void. fan fully modulating
damper
floor void
sensor
filtered air throughout the space. A series of simply unplugged and relocated as required.
In addition to the raised floor, the Denco flexible office air conditioning system comprises two
main components:
ZONE UNIT
The Zone Unit provides conditioned air to the the amount of air discharged to the floor void to ZONE UNIT LECU fan tile
floor void. It can cool, heat, humidify, dehumidify exactly match the room requirements. The zone unit automatically varies the air volume to provide
sufficient cooled or heated air to the floor void.
and filter the return air according to its inbuilt Standard noise levels can be as low as NR35.
The zone unit can be positioned inside or outside
fully programmable controls. The zone units are available in three sizes; 1, 2 of the space to be conditioned, and requires
The state of the art ‘electronically commutated’ or 3 fan modules and with the option of chilled only front access for maintenance.
fans (40% more efficient than a conventional water & split heat pump form, Denco zone units
direct driven fan) enable the zone unit to vary can be adapted for most situations.
The Denco LECU gives the Flexible Office Air- as low as NR17. The Denco LECU maintains
Conditioning System an exceptional ability to the local desired set temperature by re-circulating
cope with changing office layout requirements. a varying mixture of air from the room and UNDER-FLOOR BARRIER
The LECU is an intelligent fan tile, easily conditioned underfloor air.
A flexible silicone impregnated material air
positioned anywhere in the floor of a ‘flexible An optional electric reheater will warm the air if barrier laid beneath the raised floor creates a return
office’ and capable of operating at noise levels the local area is too cool. air path to the zone unit.
The barrier is easily and quickly relocated to suit any modifications to office area.
The Designing the flexible
THE DENCO
FLEXIBLE OFFICE AIR
CONDITIONING
SYSTEM ENABLES...
• Economical operation
• Easy maintenance with all services at for more details please visit our website at
low level in the raised floor
www.flexibleoffice.co.uk
or contact us direct on tel +44 (0)1432 277277 Denco Limited, PO Box 11, Holmer Road, Hereford HR4 9SJ UK
Tel: +44 (0)1432 277277. Fax: +44 (0)1432 268005. Web: www.denco.co.uk
© 2002 Denco Limited All Information, including illustrations, contained in this brochure is believed to be accurate and reliable. Users, however, should independently evaluate the suitability
of each product for their own application. Denco makes no warranties to the accuracy or completeness of the information and disclaims any liability regarding its use.