Sie sind auf Seite 1von 8

Quick Reference Guide

Elix® 40, 80, 120, 150

© 2016 Millipore SAS


FTPF17905 - 1.0, 03/2016
How to navigate around the screens

Overview screen 3 Workspace Application Screens


F0BT283012 - Glance

INFORMATION SERVICE CONSUMABLES

TANK FILLING RECIRCULATION


100% ..
.
. MΩ.cm
0 5 10 15 20 .
. . . . . . . . . . . . . . . . . . . . .
.
75 .
MEASURES FLOW SCHEMATIC COMPONENTS
.
.

MΩ.cm
.

10.3 .
50 .
.
.
.
.
25 .
.
102 L

23.7 °C 0
.
.
.
68 %
. . . . SANITIZATION & CLEANING HISTORY USER MANUAL
. . . . . . . .
40 60 40 60 40 60 40 60
. . . . . . . .
. . . . . . . .
. . . . . . . .
20 80 20 80 20 80 20 80
. . . . . . . .
. . . . . . . .
. . . . . . . .
0 100% 0 100% 0 100% 0 100%

10:37
10:37 09 January 2013
Janurary 09, 2013

Glance -
applications to display system information

Elix 150 - Alarms & Alerts 10:37


09 January 2013
ELIX RESISTIVITY OUT OF 17:01:08 All
RANGE (< MIN) 16 January 2016

TANK RESERVE REACHED 10:51:25


13 January 2016
Makeup process Maintenance -
Distribution process
application wizards for maintenance
System
and cleanings
10:37
09 January 2013

Configuration -
applications to change
Alarms and Alerts system settings
List of all notification messages

2
How to understand the overview screen

Makeup Button Storage Measures Distribution Button


Switches the Makeup process Tank level and Switches the Distribution process
between Standby and Ready. filling trend. between Standby and Ready.

Connection status

TANK FILLING RECIRCULATION


Makeup Status 100% .. Distribution Status
Makeup water resistivity, - Forced mode
.
. MΩ.cm
0 5 10 15 20 .
. . . . . . . . . . . . . . . . . . . . .
.
75 .

temperature and - Scheduled mode


.
.

MΩ.cm
.

alarm setpoint. 10.3 .


50 .
.
.
.
.
25 .
.
102 L
- Auto-recirculation mode.
23.7 °C 0
.
.
.
68 %
. . . . . . . . .
40 60 40 60 40 60 . . .
40 60
. . . . . . . .
. . . . . . . .

Consumable Status
. . . . . . . .
20 80 20 80 20 80 20 80

. . . . . . . .

Progard® .
.
0 100%
.
. .
.
0 100%
.
. .
.
0 100%
.
. .
.
0 100%
.
.

10:37
Janurary 09, 2013

Notification Button Opens Workspace


Opens Alarms and Alerts screen.
Color code used on display
Color changes with status.
(Blue) Process or consumable is active
(Grey) Process or consumable is not active
(Yellow) Process or consumable is in alert mode
(Red) Process or consumable is in alarm mode 3
How to display and acknowledge notification messages
1. Press the blinking notification button... 2. Press the Alarm or Alert you wish to acknowledge to open
a description of the message with information about solving it.
10:37
Janurary 09, 2013

Elix 150 - Alarms & Alerts Alarms information

... or Alarm icon to open the Alarms and Alerts screen. ELIX RESISTIVITY OUT OF
RANGE (< MIN)
17:01:08
16 January 2016
All
ELIX RESISTIVITY OUT OF RANGE (< MIN)
TANK RESERVE REACHED 10:51:25 Makeup process
13 January 2016

Distribution process Please contact your Qualified Service Representative.

ALARM STOP
System

How to launch a consumable maintenance wizard

1. Press the notification button to open the 2. Press the Maintenance Alert to launch the Consumable
Alarms and Alerts screen. replacement wizard.

10:37
Janurary 09, 2013

3 1. Pack location
Alternatively, press the Consumable icon to launch 2. Rinse duration
2
the Consumable replacement wizard directly. 3. Pack identification
. . . . . . . . .
4. Cancel or confirm
40 60 40 60 40 60
. . . . . .

1
. . . . . .
.
20 80
. .
20
15 80
. .
20
0 80
.

. . .
days . .
days .
. . . . . .
. . . . . .
0 100% 0 100% 0 100%

4
4
Workspace application list
: display detailed information in Glance : start wizard in Maintenance : change settings in Configuration

INFORMATION SERVICE CONSUMABLES

View software & product information View Service visit contract and contact View detailed information
Modify customer details information Start replacement wizard
MEASURES FLOW SCHEMATIC COMPONENTS

View water quality, hydraulic and View water quality, flow dynamics and View pump and UV lamp information
electrical measurements electrical real-time values
SANITIZATION & CLEANING HISTORY USER MANUAL

View sanitization and cleaning dates View and export daily measurements, Download User Manual in PDF format
Start cleaning wizard operations and event records

EXPORT / IMPORT SERVICE SYSTEM SETTINGS

Download or upload configuration file Restricted access service menu Change language, display brightness,
in XML format sound or date
PROCESSES ALARMS & ALERTS DISTRIBUTION SCHEDULE

View/Change the Distribution schedule (if


Adjust Makeup and Distribution process, Adjust Alarm thresholds and external applicable): Auto-recirculation, Recirculation
Options, Measure and Units signal outputs (forced) or Tank Flush
5
User interface control How to export the History/Audit Trail

Information Go to next 1. Press the History/Audit trail application in Glance Workspace.


applications screen

Confirm an 2. Select the type of data you want to export:


Maintenance
action - Daily Measurements
applications
- Daily Operations
Cancel an - Event Records
Configuration
applications action

Display water 3. Press to open the Export measurements screen.


Quit application
or wizard quality
4. Enter the Start and End date, a filename, and a save location.
Add a new item Display hydraulic
to a list settings
5. Start the export by confirming .
Remove an item Display electrical
from a list settings
How to download the user manual
Modify an item Filter data
of a list
USER MANUAL
Click on the application wizard to download
Start a wizard Export data the electronic version of the user manual.

Go to previous Copy schedule Plug in a USB flash drive to download the


screen user manual.

6
Emergency procedure in Multi-system configuration

When your Master system is not operational, the first slave


system can be converted to a Master to continue production of
purified water.

Procedure

Important: This emergency procedure is a temporary


way to ensure continuity of production. During the
3. Connect the external connectors to the backpanel of
emergency procedure, the consumable and actuator
the first slave system. The first slave will become the
lifetimes on the Distribution are not managed by a
temporary Master system.
system. Contact your Service representative to return
your Master system to operation.
4. On the first slave system, from the Overview screen
on the MMI, press the three horizontal bars on the
1. Power off the Master system using the main switch on
Distribution top right panel to activate the Distribution.
the system backpanel.
Before After
2. From the Master system backpanel, disconnect the
external connectors (C1, C2 Out and CH In). The cable MULTI-SYSTEM SLAVE RECIRCULATION
CH Out can be left in place.

Note: If the Master system is not managing duplex


Distribution pumps, connector C2 will not be installed.
DISTRIBUTION MANAGED 40
. . .
60

BY MASTER .
. .
.
. .
20 80
. .
. .
. .
0 100%

7
How to understand screen saver information

STANDBY BLINKING
Makeup and/or Distribution processes
are in STANDBY.

MΩ.cm
10.3
READY Makeup and Distribution processes
120 L are in READY.

10.3 MΩ.cm

READY + ALERT Makeup and Distribution processes


120 L REPLACE RO PUMP IN 48 HOURS are in READY with one or more alert(s).
Maintenance required.

ALERT One or more Alert(s) are active.


Maintenance required NOW.

ALARM + ALARM STOP One or more Alarm(s) are active.

Das könnte Ihnen auch gefallen