Beruflich Dokumente
Kultur Dokumente
03
Date:2015.9
No.:
Attention:
As the upgrade of the product version or other reasons, the content of this document will
not be updated regularly. Unless otherwise agreed, the document is only used as a guide,
and all statements, information and recommendations made in this document do not
constitute any express or implied warranties.
1. Technical characteristic
Function introduction
(1) This product is a solar photo-voltaic inverter power,using CPU intelligent control,
making solar controller and inverter in one. With pure sine wave output, low loss, high
conversion efficiency and reliability.
(2) Automatic identification and selection of solar, mains and battery reverse mode.
◆ W hen solar and battery voltage is high, the inverter mode will be selected
intelligently, using solar energy supply power to the load directly and charging
the battery at the same time.
◆ When the solar energy is not enough, the machine automatically switch to
solar common with battery to supply power to load;
◆ W hen solar existing and battery voltage down to low voltage protection value,
mains supply power to load (but mains don’t charge the battery), solar on the
battery charging.
◆ W hen the battery voltage is lower than the low voltage protection value, the
machine switch to mains supply power to load intelligently and charging the
battery at the same time to ensure the service life of the battery;
◆ Auto protection function. The battery pack has the perfect and reliable
protection function: the battery pack over voltage, under voltage protection, the
battery single cell over voltage, under voltage protection, charge and discharge
over current protection, charge and discharge temperature protection(high
temperature, low temperature), short circuit protection,
Index
NO. item Remark
Min. Rated value Max.
Index
NO. item Remark
Min. Rated value Max.
1 Rated power 15000W 16500W
2 Rated output current 68A
3 198Vac 220Vac 242Vac In AC mode
Output Voltage
4 205Vac 220Vac 235Vac In inverting mode
Automatically tracking and
5 55HZ 60HZ 65HZ
Output Frequency adaptive in AC mode
6 59HZ 60HZ 61HZ In inverting mode
7 Output Waveform Pure sine wave
9 Waveform Distortion 5% linear load
10 Phase Deviation 2°
11 Switching Time 4ms
12 Efficiency 90
Dynamic Response 25%~50%~25% or 50%~
13 60ms
Recovery Time 75%~50% of load。
Index
NO. Item Note
Min. Rate Value Max.
Index Remark
NO Item Min. Rate Value Max.
Operating Ambient:
Safety Requirement:
Other Requirement:
1 Placement
horizontal
Making the shell, the front panel, the fastening screw and
Grounding
2 the cabinet in good conductive contact.
Connection
Process Requirements:
4. Product size(mm):
Product Size: 640mm×570mm×1200mm
Max. Product size: 640mm×570mm×1275mm (including wheels)
Shell Material: Iron
Shell Color: Cream-Coloured
5. Product components:
1. LCD Display 2. Air Vents
3. Control switch of Solar input 1 4.Control switch of Solar input 2
5. Control switch of battery input 6. Control switch of AC input
7. Control switch of AC output 8. Ground Wires
9. Solar Input 1 10. Solar input 2
11. Battery Input 12. AC Input
13. AC Output 14. RS485 Port
15. Cooling fan
:
6. Packing(720*645*1435mm)
Accessories:User’s Manual 1 set, Warranty Card 1pc, Quality Certificate 1pc
Packing material:Wooden case
Packing quantity:1pcs
Product N.W.:180Kg
Product G.W.:210Kg
1. Touch Icon “SOLAR” as show below, it shows solar input voltage, solar input current,
solar output current and solar output power.
2. Touch Icon “BATTERY” as show below, it shows battery voltage, battery capacity and
discharge current.
3. Touch Icon “INPUT” as show below, it shows AC grid input voltage, AC gird input
current, and AC input frequency.
4. Touch Icon “OUTPUT” as show below, it shows inverter output voltage, output
frequency, output current, and loads’ power.
5. touch picture icon “inverter” as show bellow, it shows the inverter output voltage,
6. Touch picture icon “horn” on the right bottom to set the alarm or no-alarm.
7. Touch picture icon “house” on the left bottom as show bellow, there will be setting
menu.
a. Touch “AC priority Bypass”, in this mode, the inverter will have AC grid output, use AC
bypass function, not charge the battery. The inverter goes to the standby status; its
output follows with the AC grid. In this mode, if the AC grid cut off or the voltage is
beyond AC grid normal voltage, the inverter will be change to the battery inverting
mode automatically.
b. Touch “AC priority AVR”, in this mode, the inverter will automatic stabilize the AC grid
output voltage, send the power to the load and charge the battery. In this mode, if the
AC grid cut off or the voltage is beyond AC grid normal voltage, the inverter will be
c. Touch ”AC priority ECO”, in this mode, the inverter will have AC grid output, use AC
bypass function to charge the battery. The inverter not working. its output follows with
the AC grid. In this mode, if the AC grid cut off or the voltage is beyond AC grid normal
voltage, the inverter will be change to the battery inverting mode automatically in 12
seconds.
d. Touch ”Solar priority ”, in this mode, the inverter will be working like this:
① when there is sufficient solar energy, and the battery voltage is relatively high. The
solar will provide power to the load directly and charge to the battery meantime.
② If the solar energy is insufficient, both the solar energy and battery will supply power
to the loads automatically.
③ When the solar energy is insufficient, the battery voltage drops to the protection
voltage, the AC grid power will automatically supply power to the load directly but not
charge for the battery, while the solar energy will charge the battery instead.
④ when the battery voltage is lower than the protection voltage, this product will switch
to AC mode intelligently: AC will supply power to loads and charge for the battery at
the same time, to ensure the service life of the battery
⑤ When there is no solar energy, the product will use AC grid supply power to the
load or battery supply power to the load automatically.
⑥ When there is no solar energy or AC grid, the product will use battery supply power to
the load automatically.
e. Touch ”On/Off Inverter”, in this mode, will be block other modes, the inverter will be
machine will be use AC pass function to charge the battery. The inverter not working.
its output follows with the oil machine. In this mode, if the oil machine cut off or the
voltage is beyond oil machine normal voltage, the inverter will be change to the battery
(3). “Communication” is to set the address code to communicate with the inverter
(5). “Setting” is to set the display parameters and output parameters; the password is
“654321”
b. Touch “Module 1” or “Module 2”, user can check the parameters of each module.