Service Training

Checklist Air con ( 12 and 24 Volt )


356 , 357 ,358 = 24 Volt
354 = 12 Volt

1) Check if both blower fans are running ( heat exchanger on roof ) .............
if not check the jumper on PCB board
Airflow direction is to the boom ( up wards ) .............
Check the delta temp between inlet and outlet ( Min 8 –10 ° )

2) Is the compressor running ( check indicator lights on PCB board and power to the
compressor ? ..............

3) Is the system properly filled ? ( 800 –900 Gramm ) ..............


Check sight glass

4) Check the four way water valve ( only 2 hoses should be hot ) ..............

5) Check the temperature of the 2 hoses on the compressor


Suction ( big hose) ..............
Pressure ..............

6) Check the temperature of the hoses on the roof heat exchanger small ..............
big ..............
(Delta temp should min 8 – 10 °)

7) Check the blower outlets in the cab ..............

8) Check the air channel underneath the cab ..............

A.P. 8/2003 1
Service Training

Check the connections to the 4 way water valve

View to the connector ( harness )

cable 18 = BW black white Plus ( 5 Volt )


cable 19 = W white Signal
cable 20 = RW red white Minus
cable 16 = YB yellow black + 12Volt to close the valve ,- 12 volt to open
cable 15 = YB yellow black - 12 volt to close the valve , +12 volt to open

18 19 20 16 17
5 1

On the PCB board ( right behind the driver seat 9) we have to connections
Com 1 2 cable ( temperature sensor )
Com 2 5 cable water valve connections , on the board you have the cable colour stamped on

1) Check the cable connection ( remember sometimes the extension cable changes colour
without notice )
2) Check if the temp sensor is connected

A.P. 8/2003 2
Service Training

Part numbers Air con system ( 12 / 24 Volt )

Blower fans ( roof ) 356 586 2302( M10M11) Au

Frost stat ( anti icing ) 404157 ( S1)


( based in the cab heat exchanger

Thermo switch ( Min switch on Temperature ) 0019450101 (S41)


In the heat exchanger box on the roof )

Pressure switch ( low ,medium, high ) 0019734506 (S58)


Behind the left rear cab cover

Dryer cartridge 0019832023


Behind the left rear cab cover

Temperature Sensor 3563608901 (R1)


Behind the driver seat

4 way water valve ( all machines 12 Volt ) 0019444002


below the cab

This is a original Eberspächer part number only if required note this on the parts orderform

A.P. 8/2003 3