MF Series

MF-1220 Multichannel Vector Filter


The MF-1220 Vector Filter supplies the optimum data for vibration vector analysis of
large turbines and other rotating machinery. The MF-1220 accepts the overall
vibration output from vibration transducers (on up to 12 channels) and the phase
reference signal (1 pulse per revolution) from a phase marker transducer, and outputs
the vibration vector X-Y components and overall amplitude in real time on separate
channels. It also provides the flexibility to cope with both single and dual rotor
turbines. (the maximum number of channels for dual shaft monitoring is 6 channels/5
channels.)

Shaft A Shaft B
Vibration input Vibration input
1P/R CH-1 CH-6 1P/R CH-1 CH-5
88888

COUNTER REF. FILTER FILTER REF. FILTER FILTER


CARD CARD CARD CARD GATE CARD CARD CARD
SW

RPM O/A X Y O/A X Y RRM O/A X Y O/A X Y


DC DC DC DC DC DC

■ Main Functions 6. Accepts both displacement and velocity signals


1. High measuring accuracy The Vector Filter is designed to accept and process vibration
High accuracy and sophisticated analytical functions are realized by inputs both in the form of displacement signals from non-contacting
adoption of a high performance tracking filter using a high efficiency eddy-current transducers and in the form of velocity signals from
multiply type D/A converter. Filter bandwidth is selectable between velocity transducers.
0.2Hz /2Hz / AUTO. Velocity vibration signals are processed after conversion to a
proportional displacement amount in the built-in integrated circuit.
2. Capable of analyzing vibrations in the micro range Because the channels can be operated independently, both
The high dynamic range of the tracking filter (more than 60dB) and displacement and velocity signals can be processed at the same
3 selectable scale factors permit analysis of vibrations in the micro time.
range based on the X (real) and Y (imaginary) information.
7. Selectable input sensitivity
3. Order ratio (1N, 2N) vibration analysis Each channel is provided with a switch for changing the input
A function for analyzing the vibration frequency components, shaft sensitivity of the signal input from an eddy-current transducer. The
rotating speed frequency (1N) and twice the shaft rotating speed fre sensitivity of the signal input from a velocity transducer can be
quency (2N), necessary for dynamic diagnosis of rotating machinery adjusted with the built-in potentiometer.
is provided as standard. Change-over between the two functions by This affords higher flexibility in conjunction with transducers having
built-in switch or external TTL signal. a different input sensitivity.

4. Coordinate polarity for nyquist plots is selectable 8. Easy change-over between single and dual shaft
The coordinate polarity (rotating direction) can be toggled between arrangements
clockwise and counterclockwise by means of a built-in switch. Change-over between single and dual shaft monitoring is made
easy by simply exchanging a card.
5. Choice between auto trigger and manual trigger No hardware changes are necessary.
Auto trigger with excellent followup response adopted as trigger for
the phase reference signal. Manual adjustment of the trigger 9. 5-digits digital display indicator of machine speed
threshold is also possible. Equipped with a digital display to provides a 5-digit readout of the
machine speed.
■ Signal Conditioning

Vibration sensor
Vibration sensor
Phase ref. sensor Band-pass filter
Gain

Rotor

RPM
Tracking
Phase ref. signal

Vibration signal Ao
(overall)
90

Band-pass output A
(filtered)

180 0
A

270

■ Specifications
Input channels
RPM range ■ Dual arrangement Shaft A/1 : Up to 6ch
Shaft B/1 : Up to 5ch
Single arrangement 1 to 12ch
■ 50 to 100,000rpm
Display
RPM ■ Readout 5 digits LED (red) 50 to 99,999rpm
Accuracy ±(0.003% of rdg.+1 digit) at 25°C (77°F)
Resolution 1 rpm
Trigger ■ LED (yellow)

Tracking filter
Operating range ■ 50 to 100,000rpm (0.83 to 1,666Hz)
Band width (BW) ■ 0.2Hz or 2Hz, selectable
BW select mode ■ Auto or Manual
Auto mode <1,000rpm=0.2Hz BW
>1,000rpm=2Hz BW
Filter response ■ 0.2Hz BW=0.6rpm/sec.
2Hz BW=60rpm/sec.
Dynamic range ■ 60dB or more
Analysis ratio ■ 1× (1N) or 2× (2N), selectable
Select analysis ratio ■ Manual select or TTL level select
TTL select signal L=1× (1N) (or OPEN)
H=2× (2N)
MF Series
MF-1220 Multichannel Vector Filter
Input signal
Vibration signal ■ Displacement or velocity, selectable
Input impedance 10kΩ
Input sensitivity Displacement transducer
4V/mm pk-pk, 5V/mm pk-pk, 8V/mm pk-pk
Velocity transducer
2.5 to 40mV/mm/sec. pk
Full scale range 100/200/500µm pk-pk F.S., selectable
Input channel Max. 12ch (rear panel screw terminal and BNC)
Phase reference signal input
■ Input impedance 10kΩ
Signal level 0.4 to 100V pk
Pulse width >10µs
Trigeer mode Auto or manual, selectable
Manual trigger level −20 to +20V
Trigger slope Positive or negative edge, selectable
Signal input Rear panel screw terminal and BNC
Output
RPM ■ 0.05 to 10VDC/50 to 10,000rpm or
0.005 to 10VDC/50 to 100,000rpm
Resolution 12 bit/F.S.
Overall amplitude ■ 0 to 10VDC/0 to full scale
Accuracy ±3% of F.S. at 25°C (77°F)
X,Y ■ X (real) : 0 to ±10VDC
Accuracy ±3% of F.S. at 25°C (77°F)
Y (imaginary) : 0 to ±10VDC
Accuracy ±3% of F.S. at 25°C (77°F)
Output impedance ■ 100Ω
X, Y coordinate polarity ■ CW (clockwise) or CCW (counter clockwise), selectable
Each signal output ■ Rear panel terminal and D-Sub (25p) connector
Trigger pulse ■ −0.5 to +0.5V(PL), 4 to 5V(PH)
(Front panel BNC)

Phase reference signal Revolution


Phase CW CCW
Vibration signal angle Y
X Y X Y
0 CCW
0 +A 0 +A 0
180 A 0
X
90 90 0 -A 0 +A
CW

180 180 -A 0 -A 0

270 270 0 +A 0 -A

A : 10V/F.S.
Others
Power supply ■ 100VAC±10%, 47 to 440Hz Max. 90VA
Insulation resitance ■ 100MΩ or more at 500VDC (power-ground)
Dielectric strength ■ 1,500VAC, 1 min. (power-ground)
Temperature range ■ Operating : 0 to 40°C (32 to 104°F)
Storage : 20 to 60°C (4 to 140°F)
Relative humidity : Up to 95% RH (noncondensing)
Front panel finish ■ Anodized aluminum, hair-line finish
Mass ■ Approx. 12kg
Accessory ■ Spare fuse (3A. 1pc.)
Power supply cable (2.5m. 1pc)

■ Outline Drawing

(Front view)

101.5
177

465 17
483 314.5

(Rear view)

446

Dimensions : mm