Sie sind auf Seite 1von 2

SERVICE BULLETIN

Kobelco Construction Machinery Co., Ltd.


Customer Support Department FS Group
Authorized by; Issued by;
CLASSIFICATION :Technical Info
Issue Date : 2005/9/16
Bulletin No. : S030-60-B001
Subject : Arm recirculation timing adjustment (Hidden mode)
Applicable Area : Japan, China, South East Asia, Newzealand
Applicable Model : SK200-6E / SK230-6E

Applicable S/No. : Show below

1. Background of Information
We would like to inform you that the adjusting procedure of the "Arm recirculation timing
adjustment". If customer complains the speed of arm digging, adjust this value as necessary.

2. Information
1. Initial value is set to 00.06 (Indicated ” 6” on display) at the factory before shipment.
2. Adjustable range: 1, 3, 6, 8, 10, 15, 17, 20, 30, 40, 50, 80, 100, 150, 300, 400, 500

Arm digging speed and fuel consumption increase when the value is raised.

3. Applicable serial No. of Manufacturers improvement


MODEL APPLICABLE S/No APPLICABLE Ver.
SK200-6E (6ES) YN09-36768 and up
Ver. 16.00 and up
SK210-6E (6ES) YQ09-05217 and up
SK230-6E (6ES) LQ10-04895 and up
Ver. 05.00 and up
SK250-6E (6ES) LL10-03635 and up
Note: Australia is off the subject. (Software is different)
4. Adjusting procedure
1-1 Turn on key switch while pressing buzzer stop switch.
You will enter "Service Diagnosis" function, which monitor screen show No.1 display.
(Refer to display A)

1-2 Press screen change switch to display the desired screen display No. 20, which shows Prop
Valve for P1 BY-PASS. (Refer to display B)

No.1 NO.20 Cluster gauge Switch location


MAIN CONT. P/N PROPO-VALVE Screen change Buzzer stop Work mode selector

"YN22E0123F4" D-1 P1 BY-PASS


PROGRAM VER COMP.350mA 0.6M
VER 16.00 MEAS. 345mA 0.6M

Display A Display B
This bulletin is issued for information only and is not
an authorization for warranty claim submission. Working light

1
Issue Date : 2005/9/16
Bulletin No. : S030-60-K002
4. Adjusting procedure
1-3 Press "Working light switch" 3 times, keeping "Work mode selector switch" pressed, and the
"adjustment mode" appears. (Refer to Display C)

1-4 Setting procedure:


Initial adjustment mode display: (Refer to display C)
MAIN CONT. P/N
"ARM IN ADJ"
VER"00.06"

Press "Work mode switch"..... The adjusting value rises.


Press "Buzzer stop switch"..... The adjusting value lowers.
MIN "00.01" (Sequence conflux) <= "00.06" (Initial value) => MAX "05.00" (Conflux flow)

1-5 Return the diagnosis screen.


Press "Screen change switch" to confirm and data will be memorized by controller.
Display will return to the No.1 - display A condition.

No.1 NO.20 NO.1


MAIN CONT. P/N PROPO-VALVE MAIN CONT. P/N
"YN22E0123F1" D-1 P1 BY-PASS "ARM IN ADJ"
PROGRAM VER COMP.350mA 0.6M PROGRAM VER
VER 15.00 MEAS. 345mA 0.6M VER 00.06

Display A Display B Display C

Note: Factory Initial setting value is 00.06 during shipment.


1. The value (00.01 to 05.00) changes the speed of the arm-in operation.
2. When the value is increased, the arm-in speed at heavily digging improves.
3. When the value is decreased, it is effective in slope finishing operation.
4. There is a possibility that fuel consumption changes according to the adjustment of the value.

Cluster gauge Switch location


Screen change Buzzer stop Work mode selector

Working light

Das könnte Ihnen auch gefallen