Preliminary Design of Beam

1. Effective depth calculation:

Deflection criteria:
For Limit State of Serviceability factors :
Span/Depth =αβγδλ
Where α, β, γ, δ and λ are modification factors
α = 26 (for continuous beam)
β = 1 (for span less than 10m)
γ = 0.8 (Modification Factor assumed)
δ = 1.25 (for pc=0%)
λ = 1 (for rectangular section)
The greatest span of the Main Beam,
L = 6700 mm
Span/Depth =αβγδλ
D = Span/ α β γ δ λ = 6700/26 = 257.69mm.(min)

Adopt overall depth,D=550 mm

Width of beam,B=2/3 *550 =366.67 mm=375 mm

Secondary Beam:

D = Span/ α β γ δ λ = 6700/26 = 257.69mm.


Adopt overall depth,D=275 mm

Width of beam,B=2/3 *275 =183.33 mm=200 mm

Moment criteria
Critical beam
Total Area of Trapezoid = 1/2 (a + b) * h
A1 = 1/2 (a + b) * h = 1/2 (6+2)*2.5 = 10 m2
A2 =1/2 (a + b) * h = 1/2 (6+2)*3.5 = 14 m2
Total Area of Slab = (10+14) = 24 m2
2. Load Calculation:
2.1 Slab Load
Dead Load = γ x A x t = 25x24x.12 = 72 KN
2 2
Intensity of Live Load = 4 KN/ m x 24 m = 96 KN
Total Load = 168 KN
2.2 Floor Finish Load
12.5 mm thick ceiling plaster = 20.4x0.125x24 = 6.12 KN
25 mm thick Marble floor = 26.5x0.025x24 = 15.9 KN
Total load = 22.02 KN
2.3 Wall Load
Wall width = 230 mm
Floor/ Wall Height = 3.30 m
Dead load = 19x0.23x3.30x6.99 =106.15 KN
Deduct 35% opening = 0.35 x 106.15 = 37.15 KN
Total wall load = (106.15 – 37.15) = 69 KN

Total Load = (168+22.02+69) =259.02 KN


Total UDL (Wu) = 259.02/6.99
= 37.06 KN/m
Factored/Ultimate load (Wu) = 1.5 x 37.06
= 55.58 KN/m
3. Check Depth:

Ultimate Moment (Mu) = Wul2 /12


= (55.58x6.992)/12
=226.32 KN.m

Concrete grade =M20


Steel type =Fe 415
2
Mu = 0.138 x fck x b x d
226.32 = 0.138 x 20 x 1000 x d2
d = 522.8079 mm

Adopt d = 600 mm
Width of beam assumed = 400 mm