LINEAR GRILLES & REGISTERS

WE SHAPE

AIR

PRODUCT BULLETIN

PRODUCTS CATALOGUE
Dubai Head Office:

Tel: +971 4 706 97777


Fax: +971 4 706 9787

Abu Dhabi Branch:

Tel: +971 2 645 0107


Fax: +971 2 645 0167

Email: betai@betag.com

P.O. Box 50708, Dubai


United Arab Emirates

www.betag.com
SINGLE DEFLECTION LINEAR GRILLES & REGISTERS 1-2

DOUBLE DEFLECTION LINEAR GRILLES & REGISTERS 3-4

ACCESSORIES 5-6

ALUMINUM FLOOR GRILLES-IMP KLIMA 7-10

PERFORMANCE DATA 11-17


LINEAR GRILLES & REGISTERS
SINGLE DEFLECTION LINEAR GRILLES & REGISTERS

TYPE: RLG
B + 50 mm
5.4 *16 mm
mm 30 mm

27 mm

B - 10 mm

TYPE: RLR
B + 50 mm
5.4 *16 mm 30 mm
mm

27 mm

65 mm

B - 5 mm * 12 MM OPTIONAL

The single deflection linear grille is a wall mounted grille, used as an exhaust or return grille in
cooling, heating or air ventilation application.

The single deflection linear grille is composed of a set of fixed horizontal straight bars attached to a
frame, both are manufactured from extruded aluminium sections.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


LINEAR GRILLES & REGISTERS
SINGLE DEFLECTION LINEAR GRILLES & REGISTERS

OO deflection ( Standard) 15O DEFLECTION, ONE WAY 15O DEFLECTION, 2 WAY

FIXING

>> Front bars have one of the following basic designs:


- OO deflection bars ( Standard)
- 15O deflection, one way
- 15O deflection, two way

>> Front bars are assembled in horizontal straight lines With a center to
center spacing of 16 mm & 12 mm.
>> Available with easily removeable opposed blades damper attached to
the frame by means of (S) clips to ensure tight attachment and maximum
flexibility. The damper Is made of extruded aluminium bars and opening of
the damper is easily adjusted by means of control Iever that is driven by
a screw driver from the front face of the register.

Available type of finishings :


Natural anodized aluminium finish.
powder coated to RAL codes.

TYPES & MODELS


A A

RLG B RLR B

ORDERING SYSTEM
RLR : Single deflection linear grille with damper black/ mill finish
RLG : Single deflection linear grille without damper. TYPE

SIZE : Width x Height SIZE

CURVE : If curved required CURVE

RAL : Powder coated finish as per RAL codes.


Anodized : Anodized aluminium finish. FINISH

Example: RLR 1000x150 Anodized

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


LINEAR GRILLES & REGISTERS
DOUBLE DEFLECTION LINEAR GRILLES & REGISTERS

TYPE: SLG
B + 50 mm
5.4 *16 mm 30 mm
mm

45 mm

B - 10 mm

TYPE: SLR
B + 50 mm
5.4 *16 mm 30 mm
mm

83 mm

B - 5 mm * 12 MM OPTIONAL

The double deflection linear gille is a wall mounted gille, used as an exhaust or retun grille in
cooling, heating or air ventilation application.

The double deflection linear grille is composed of a set of fixed horizontal straight bars in the front
face and individually adjustable vertical deflection on the rear to control air flow pattern, both are
manufatured from extruded aluminum sections.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


LINEAR GRILLES & REGISTERS
DOUBLE DEFLECTION LINEAR GRILLES & REGISTERS

OO deflection ( Standard) 15O DEFLECTION, ONE WAY 15O DEFLECTION, 2 WAY

FIXING

>> Front bars have one of the following basic designs:


- OO deflection bars ( Standard)
- 15O deflection, one way
- 15O deflection, two way

>> Front bars are assembled in horizontal straight lines With a center to
center spacing of 16 mm & 12 mm.
>> Available with easily removeable opposed blades damper attached to
the frame by means of (S) clips to ensure tight attachment and maximum
flexibility. The damper Is made of extruded aluminium bars and opening of
the damper is easily adjusted by means of control Iever that is driven by
a screw driver from the front face of the register.

Available type of finishings :


Natural anodized aluminium finish.
powder coated to RAL codes.

TYPES & MODELS


A A

SLG B SLR B

ORDERING SYSTEM

SLR : Double deflection linear grille with damper black/ mill finish
TYPE
SLG : Double deflection linear grille without damper.

SIZE : Width x Height SIZE

CURVE : If curved required CURVE

RAL : Powder coated finish as per RAL codes.


FINISH
Anodized : Anodized aluminium finish.
Example: SLR 2000x250 RAL 9016

ALLDETAILS
ALL DETAILSSUBJECT
SUBJECTTO
TOCHANGE
CHANGEWITHOUT
WITHOUTPRIOR
PRIORNOTICE
NOTICE
LINEAR GRILLES & REGISTERS
ACCESSORIES

1- ONE END LINEAR GRILLE/REGISTER (D 1)


AVAILABLE IN ANY STANDARD SIZE.

2- INTERMEDIATE LINEAR GRILLE/REGISTER (D2)


AVAILABLE IN ANY STANDARD SIZE. D1

3- CORNER PIECES (D3,D4,DS)


AVAILABLE IN ANY COMBINATION OF B, X. Y &

D2
B (mm) x (mm) Y (mm) (degree)
X
100 300 300 45O
150 600 600 90O
200 800 800 135O
250 1000 1000
300 1200 1200

D3
B
B
X Y

X Y
D4 B

D5

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


LINEAR GRILLES & REGISTERS
ACCESSORIES

4- CURVED SHAPE LINEAR GRILLES (D6)

D6

Minimum radius = 1000 mm


Used as Supply/Return linear grille
m
:1
ius
ra d
um
nim
Mi

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


ALUMINUM FLOOR GRILLES

12,5

H/B
AR-8

12,5

H/B
AR-9

Application
Floor fixed bar aluminum grilles AR-8, AR-9 are used for air supply and exhaust in all kinds of low pressure air
handling.

Description
Floor fixed bar aluminum grilles AR-8, AR-9 are made of cold-worked sectional aluminum, galvanized in natural
aluminum colour, fixed vertical vanes are designed so as to achieve the horizontal air injection at AR-8 and in the
15O angle air injection at AR-9. Both are intended for floor installation. The attached accessory devices for air flow
rate and direction control are made of black varnished pickled sheet.

AR-8, AR-9
The supply and exhaust air grilles AR-8, AR-9 consist of supporting frames and vertical fixed bars.

54

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


ALUMINUM FLOOR GRILLES

1. Chart of air pressure drop and sound level-straight adjusted vanes


Symbols:
Pcel (Pa) total air pressure drop
LN estimated sound power level according to NR- curves
NR estimated sound power level according to dB (A)
LN
A
open
25%
10
50%

Vef

45
50
40

40
100%
30

50
35
pcef
20

45
30

40
25 NAARR

Damping adjustment
L
Table for sound data correction factor 10

35
2
Fef (m ) 0.005 0.01 0.02 0.05 0.1 0.2 0.4

Correction -13 -10 -7 -3 0 +3 +6

)]
[dB 0
(A
3
L NA LNNR 5

NA
4

25

L
The chart is valid for the exhaust air grilles AR-8 and AR-9 with 3
1 2 3 4 5 6 10
accessory device.
Effective intake air velocity vef [m/s]
2. Chart for detemination of effective intake velocity.

Effective discharge area Fef [m]


05

4
5
1

0,0

0,0

0,0
0,0

0,1

0,2

0,3

0,4
0,5
0,0

0,0

10

8
7

5
Effective intake velocity Vef [m/s]

1,5
30 50 100 200 500 1000 2000 5000 10000 20000
3
Intake air flow Q [m /h]

Example : Result:
Q = 1000 m3/h Vef = 5.3 m/s
2
Fef = 0.05 m (from table 4)

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


ALUMINUM FLOOR GRILLES

3. Room sound attenuation chart


3
V’ (m ) calculate volume depending on room reverberation
3
V (m ) real volume of the room

For the grilles the following values are required:


1. Normal rooms V’ = V
2. Rooms with explicitly reverberating walls V’ = 0.5V
3. Rooms with absorption walls V’ = 2V

14
00
13 20

12
00
10
11
3 ]
10 [m
V’ 5 00
9 e
m
lu
Vo 2 00
Room attenuation [dB(A)]

8
7
100
6
4 Table for effective intake areas
5 50

4
3
2 20
Effective intake 1
BxH Area Fef (m2)
mm AR-8, AR-9
0,7 1,0 2,0 3,0 4,0 5,0
225 x 75 0.004
325 0.006 Distance from sound source [m]
425 0.009
525 0.011
625 0.013
825 0.017
1025 0.021
1225 0.026
The intake air flow is determined by measuring the intake air velocity
225x 125 0.009 at parallel set-up bars. The intake air flow can be calculated as
325 0.013
425 0.017 follows:
525 0.021
625 0.026
825 0.033 Q = Vef x Fef x 3600
1025 0.041
1225 0.049 3
Q = (m /h)
325 x 225 0.026
425 0.033 Vef (m/s)
525 0.041 2
625 0.049 Fef (m )
825 0.066
1025 0.082
1225 0.090
The right for technical alterations reserved!
425 x 325 0.049
525 0.060
625 0.072
825 0.095
1025 0.120
1225 0.140
625 x 425 0.095
825 0.122
1025 0.155
1225 0.185
1025 x 525
1225

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


ALUMINUM FLOOR GRILLES

Induction i
Chart for determination of nominal sizes, induction and air
Effective discharge velocity vef[m/s]
stream tempreture for aluminium grilles AR-8, AR-9
4 5
4 3 2 1,5 1 Valid for: B/H 12
1225 10
5
1025
6

0,8 m
1225
7 15
825 1025 VL[m/s]
8
O 3
9
tL [ C] Q[m /h]
625 825 1225 VL = 0,2 m/s

b02
O
10 20 t2 [ C]
4000
625

Occupied zone
825 30
525
3000

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


40
425 625 1225
525 1025
2000
425 825
1500
325 625 1225
525 1025
Width B [mm]

1000
425 825
800
325 625
600
525
500
225 425
400

A 0,2L
325
300
225
200 150 0,05 0,04 0,03
425 325 225 125 75 Discharge air flow Q [m3/h] tt
Temperature quotient
Height H [mm] tz
Terminal velocity VL [m/s]
4 5 6 7 8 9 10 15 20
0,75 0,5 0,4 0,3 0,2
20
1,0
The application of heavy Throw L [m]
printed dimensions 19
recomended.
10
1,5

Throw L [m]
9
Sp 8
re 7
ad
of 1,0 6
a ir 0,9
s tr e 5
am 0,8
b0 0,7
.2[
m] 0,6 4 The right for technical changes reserved.
3
LINEAR GRILLES & REGISTERS
PERFORMANCE DATA

Products Testing
The following tables include the results of tests conducted on three single deflection linear grilles. The
test results include Noise Criteria (NC). Static pressure versus air flow, throw and Ak. The grilles were
selected and supplied by Beta In August 1994. The Extrapolations and interpolations were made to Cover
a range of sizes and parameters according to the ETL testing laboratories Inc. who conducted the tests.

Test Method
The linear grilles Were tested in accordance with the Air Diffusion Council test code for
grilles registers and diffusers No. ADC 1062: GRD-84. The grilles were tested in the ETL
testing laboratories.
The 470m2 reverberation room was used to conduct the tests. Quiet test air was provided' by a variable
volume air supply. Air volume was measured by the use of calibrated Orifice metering station while the
static pressure was measured employing a Dwyer Model 166-12,1/8’ diameter standard pitot tube and
read on a dwyer manometer Model 424-5.

Acoustical data was obtained Employing a Bruel and Kjaer digital frequency analyzer type 2131 and
analyzed on a computer. The reference sound source for this test was a calibrate ILG Fan Serial No. 17-
05-066A. The Octave band sound power levels were plotted on a graph of noise criteria curves which
is in the ADC test! codes.

NOTES:

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


LINEAR GRILLES & REGISTERS
PERFORMANCE DATA

PERFORMANCE DATA - SUPPLY SLR, SLG, RLR, RLG

12mm Spacing - 0O DEFLECTION - VERTICAL BLADES AT 0O


THROW
*IMPERIAL UNITS
Air Terminal Velocity (FPM) vs. Throw (Ft)
WIDTH CFM per foot Vn Pt NC 4” Height - 12mm Spacing - 0O
350

90 270 0.024 16
300
700 CFM
120 360 0.032 19

Air Terminal Velocity, FPM


4 Inch (12mm 250 500 CFM
150 450 0.040 20 300 CFM
space) An=0.333 200
180 540 0.050 23
sq.ft. Ak=0.243 150
210 630 0.065 26
sq.ft. 100
240 720 0.085 30
50
270 810 0.107 35
210 420 0.041 18 0
6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”
Throw, Ft
240 480 0.054 23
6 Inch (12mm
270 540 0.067 28 Air Terminal Velocity (FPM) vs. Throw (Ft)
space) An=0.500 6” Height - 12mm Spacing - 0O
300 600 0.082 32 300
sq.ft. Ak=0.342
330 660 0.096 34 250
sq.ft. 700 CFM
360 720 0.121 37 Air Terminal Velocity, FPM
200
405 810 0.146 40 500 CFM

150
240 360 0.023 19
300 CFM
270 405 0.027 23 100
8 Inch (12mm
300 450 0.032 27 50
space) An=0.667
360 540 0.047 33
sq.ft. Ak=0.478 0
6”

2’6”

4’6”

6’6”

8’6”

10’6”

12’6”

14’6”

16’6”

18’6”

20’6”

22’6”

24’6”
405 608 0.057 37
sq.ft.
420 630 0.067 41 Throw, Ft

Air Terminal Velocity (FPM) vs. Throw (Ft)


450 675 0.077 45 O
8” Height - 12mm Spacing - 0
210 252 0.006 15 300

240 288 0.008 18 250


10 Inch (12mm
Air Terminal Velocity, FPM

850 CFM
270 324 0.010 22
space) An=0.834 200
700 CFM
300 360 0.012 25
sq.ft. Ak=0.657 150
330 396 0.014 29 500 CFM
sq.ft.
405 486 0.022 36 100

450 540 0.027 39 50

SYMBOLS
0
CFM : Air volume in cubic feet per minute.
6”

2’6”

4’6”

6’6”

8’6”

10’6”

12’6”

14’6”

16’6”

18’6”

20’6”

22’6”

24’6”

Ak : Effective Face Area in feet square per feet length


An : Neck Area in feet square per feet length Throw, Ft

Vn : Neck Velocity in feet per minute


Pt : Total Preasure in inches water gauge Air Terminal Velocity (FPM) vs. Throw (Ft)
Th : Throw in feet 10” Height - 12mm Spacing - 0O
300
N.C. : Noise criteria

250
CONDITIONS
Air Terminal Velocity, FPM

1100 CFM
* Supply 200
0
* Vertical blades deflection: 0 deflection 900 CFM

* Noise Criteria values are based on (10 dB) room attenuation 150
700 CFM
* Throw figures are measured for Linear Grilles fixed at 6” from the ceiling
100
* Damper is fully open
* Data is based on 1ft length
50
CORRECTIONS ON NOISE CRITERIA FOR OTHER LENGTHS
Length 3ft 6ft 10ft 0
6”

2’6”

4’6”

6’6”

8’6”

10’6”

12’6”

14’6”

16’6”

18’6”

20’6”

22’6”

24’6”

N.C. (+4) (+7) (+9) Throw, Ft

12 ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


LINEAR GRILLES & REGISTERS
PERFORMANCE DATA

PERFORMANCE DATA - SUPPLY SLR, SLG, RLR, RLG

12mm Spacing - 0O DEFLECTION - VERTICAL BLADES AT 45O


THROW
*IMPERIAL UNITS
WIDTH CFM per foot Vn Pt NC Air Terminal Velocity (FPM) vs. Throw (Ft)
4” Height - 12mm Spacing - 45O
90 270 0.001 15 350

120 360 0.004 16 700 CFM


4 Inch (12mm 300
150 450 0.043 20

Air Terminal Velocity, FPM


space) An=0.333 180 540 0.082 24 250
500 CFM

sq.ft. Ak=0.202 210 630 0.121 30 200

sq.ft. 240 720 0.160 36 300 CFM


150
270 810 0.194 39
135 270 0.029 15 100

180 360 0.058 20


6 Inch (12mm 50
210 420 0.071 24
space) An=0.500 240 480 0.094 29 0
6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”
sq.ft. Ak=0.283 270 540 0.117 33 Throw, Ft

sq.ft. 300 600 0.142 36 Air Terminal Velocity (FPM) vs. Throw (Ft)
6” Height - 12mm Spacing - 45O
330 660 0.167 39 400

210 315 0.021 18


350
8 Inch (12mm 240 360 0.028 22
700 CFM
300
270 405 0.040 27

Air Terminal Velocity, FPM


space) An=0.667
300 450 0.047 31 250
sq.ft. Ak=0.396
330 495 0.060 33
200 500 CFM
sq.ft. 360 540 0.072 36
150
405 608 0.092 40
210 252 0.009 15 100
300 CFM

10 Inch (12mm 240 288 0.015 20


50
270 324 0.016 23
space) An=0.834
300 360 0.023 27 0
6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”
sq.ft. Ak=0.548 Throw, Ft
330 396 0.024 31
sq.ft. 360 432 0.031 34 Air Terminal Velocity (FPM) vs. Throw (Ft)
O
8” Height - 12mm Spacing - 45
405 486 0.039 37 300

250
850 CFM
SYMBOLS
Air Terminal Velocity, FPM

700 CFM
200
CFM : Air volume in cubic feet per minute.
Ak : Effective Face Area in feet square per feet length
150
AN : Neck Area in feet square per feet length
Vn : Neck Velocity in feet per minute 500 CFM

Pt : Total Preasure in inches water gauge 100

Th : Throw in feet
N.C. : Noise criteria 50

0
6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”
CONDITIONS Throw, Ft
* Supply
O Air Terminal Velocity (FPM) vs. Throw (Ft)
* Vertical blades deflection: 45 deflection 10” Height - 12mm Spacing - 45
O

* Noise Criteria values are based on (10 dB) room attenuation 250

* Throw Figures are measured for Linear Grilles fixed at 6” from the Ceiling
1100 CFM
* Damper is fully open
200
Air Terminal Velocity, FPM

* Data is based on 1ft length 900 CFM

CORRECTIONS ON NOISE CRITERIA FOR OTHER LENGTHS


150
Length 3ft 6ft 10ft 700 CFM

N.C. (+4) (+7) (+9)


100

50

0
6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”
Throw, Ft

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


LINEAR GRILLES & REGISTERS
PERFORMANCE DATA

PERFORMANCE DATA - RETURN SLR,SLG,RLR,RLG

12mm Spacing - 0O DEFLECTION

*IMPERIAL UNITS

WIDTH CFM per foot Ps NC SYMBOLS


CFM : Air volume in cubic feet per minute.
90 0.001 15
PS : Negative static pressure in inches water gauge.
120 0.027 20 N.C. : Noise Criteria

150 0.053 24 CONDITIONS


4 inch 180 0.079 29 * Return
* Noise Criteria is based on (10 dB) room attenuation.
210 0.105 33 * Damper is fully open.
* Data is based on 1ft length.
240 0.150 33
270 0.180 33
135 0.030 19
180 0.050 20
210 0.065 24
6 inch 240 0.090 29
270 0.110 33
300 0.135 37
330 0.160 41
210 0.025 15
240 0.030 25
270 0.040 33
8 inch 300 0.050 35
330 0.060 35
360 0.070 44
405 0.090 42
240 0.025 15
250 0.025 22
270 0.030 28
10 inch 330 0.035 29
390 0.055 35
450 0.075 42
480 0.085 46

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


LINEAR GRILLES & REGISTERS
PERFORMANCE DATA

PERFORMANCE DATA - SUPPLY SLR, SLG, RLR, RLG

16mm Spacing - 0O DEFLECTION - VERTICAL BLADES AT 0O


THROW
*IMPERIAL UNITS
Air Terminal Velocity (FPM) vs. Throw (Ft)
WIDTH CFM per foot Vn Pt NC 4” Height - 16mm Spacing - 0
O

350

90 270 0.001 15
300
700 CFM
120 360 0.014 17

Air Terminal Velocity, FPM


4 Inch (16mm 250 500 CFM
150 450 0.026 19 300 CFM
space) An=0.333 200
180 540 0.039 21
sq.ft. Ak=0.248 150
210 630 0.051 23
sq.ft. 100
240 720 0.078 30
270 810 0.105 37 50

210 420 0.031 19 0


6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”
240 480 0.049 23 Throw, Ft
6 Inch (16mm
270 540 0.062 29 Air Terminal Velocity (FPM) vs. Throw (Ft)
O
space) An=0.500 6” Height - 16mm Spacing - 0
300 600 0.077 32 300
sq.ft. Ak=0.347
330 660 0.096 35 250
sq.ft. 700 CFM
360 720 0.111 38

Air Terminal Velocity, FPM


200
405 810 0.139 41 500 CFM

150
210 315 0.011 15
300 CFM
270 405 0.019 21 100

8 Inch (16mm 300 450 0.023 28 50


space) An=0.667 330 495 0.028 30
0
sq.ft. Ak=0.495
6”

2’6”

4’6”

6’6”

8’6”

10’6”

12’6”

14’6”

16’6”

18’6”

20’6”

22’6”

24’6”
360 540 0.032 32
sq.ft. 405 608 0.042 36 Throw, Ft

450 675 0.052 39 Air Terminal Velocity (FPM) vs. Throw (Ft)
O
8” Height - 16mm Spacing - 0
240 288 0.005 15 300

270 324 0.006 21 250


10 Inch (16mm
300 360 0.008 24 850 CFM
Air Terminal Velocity, FPM

space) An=0.834 200


700 CFM
330 396 0.009 28
sq.ft. Ak=0.665 150
360 432 0.011 31 500 CFM
sq.ft.
405 486 0.014 35 100

450 540 0.017 38 50

SYMBOLS 0
6”

2’6”

4’6”

6’6”

8’6”

10’6”

12’6”

14’6”

16’6”

18’6”

20’6”

22’6”

24’6”

CFM : Air volume in cubic feet per minute.


Ak : Effective Face Area in feet square per feet length Throw, Ft

An : Neck Area in feet square per feet length


Vn : Neck Velocity in feet per minute Air Terminal Velocity (FPM) vs. Throw (Ft)
O
Pt : Total Preasure in inches water gauge 10” Height - 16mm Spacing - 0
300
Th : Throw in feet
N.C. : Noise criteria 250

CONDITIONS 1100 CFM


Air Terminal Velocity, FPM

200
* Supply
900 CFM
* Vertical blades deflection: 0 0deflection
150
* Noise Criteria values are based on (10 dB) room attenuation 700 CFM
* Throw Figures are measured for Linear Grilles fixed at 6” from the Ceiling
100
* Damper is fully open
* Data is based on 1ft length
50
CORRECTIONS ON NOISE CRITERIA FOR OTHER LENGTHS
Length 3ft 6ft 10ft 0
6”

2’6”

4’6”

6’6”

8’6”

10’6”

12’6”

14’6”

16’6”

18’6”

20’6”

22’6”

24’6”

N.C. (+4) (+7) (+9) Throw, Ft

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


LINEAR GRILLES & REGISTERS
PERFORMANCE DATA

PERFORMANCE DATA - SUPPLY SLR, SLG, RLR, RLG

16mm Spacing - 0O DEFLECTION - VERTICAL BLADES AT 45O


THROW
*IMPERIAL UNITS
WIDTH CFM per foot Vn Pt NC Air Terminal Velocity (FPM) vs. Throw (Ft)

90 270 0.001 15 4” Height - 16mm Spacing -45O


350
4 Inch (16mm 120 360 0.026 19
700 CFM
space) An=0.333 150 450 0.051 23 300

Air Terminal Velocity, FPM


180 540 0.076 27 250
sq.ft. Ak=0.184
210 630 0.101 31 500 CFM

sq.ft. 240 720 0.130 36 200

270 810 0.159 41 150 300 CFM

180 360 0.048 19


100
6 Inch (16mm 210 420 0.061 24
space) An=0.500 240 480 0.079 29 50

300 540 0.102 33


sq.ft. Ak=0.271 0
360 600 0.132 36 6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”
Throw, Ft
sq.ft. 420 660 0.161 39
450 900 0.176 41 Air Terminal Velocity (FPM) vs. Throw (Ft)
210 315 0.021 17 6” Height - 16mm Spacing -45O
350

8 Inch (16mm 240 360 0.028 22


270 405 0.035 25 300
700 CFM
space) An=0.667
300 450 0.047 30 Air Terminal Velocity, FPM
250
sq.ft. Ak=0.384 330 495 0.055 33 500 CFM
200
sq.ft. 360 540 0.067 36
405 585 0.080 39 150
300 CFM
210 252 0.010 15
100
240 288 0.013 19
10 Inch (16mm
300 360 0.021 25 50
space) An=0.834 330 396 0.024 29
0
sq.ft. Ak=0.532 405 486 0.039 36 6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”
Throw, Ft
450 540 0.047 39
sq.ft.
480 576 0.052 41 Air Terminal Velocity (FPM) vs. Throw (Ft)
O
8” Height - 16mm Spacing - 45
350

300
Air Terminal Velocity, FPM

850 CFM
250
700 CFM

200

150
500 CFM

SYMBOLS 100

CFM : Air volume in cubic feet per minute.


50
Ak : Effective Face Area in feet square per feet length
An : Neck Area in feet square per feet length 0
Vn : Neck Velocity in feet per minute 6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”
Throw, Ft
Pt : Total Preasure in inches water gauge
Th : Throw in feet Air Terminal Velocity (FPM) vs. Throw (Ft)
O
N.C. : Noise criteria 10” Height - 16mm Spacing - 45
350

CONDITIONS 300
1100 CFM
Air Terminal Velocity, FPM

* Supply 250
* Vertical blades deflection: 45 0 deflection 900 CFM

* Noise Criteria values are based on (10 dB) room attenuation 200

* Throw Figures are measured for Linear Grilles fixed at 6” from the Ceiling 700 CFM
150
* Damper is fully open
* Data is based on 1ft length 100

CORRECTIONS ON NOISE CRITERIA FOR OTHER LENGTHS


50

Length 3ft 6ft 10ft


0
6” 2’6” 4’6” 6’6” 8’6” 10’6” 12’6” 14’6” 16’6” 18’6” 20’6” 22’6” 24’6”
N.C. (+4) (+7) (+9) Throw, Ft

16 ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE


LINEAR GRILLES & REGISTERS
PERFORMANCE DATA

PERFORMANCE DATA - RETURN SLR,SLG,RLR,RLG

O
16mm Spacing - 0 DEFLECTION

*IMPERIAL UNITS

WIDTH CFM per foot Ps NC SYMBOLS


CFM : Air volume in cubic feet per minute.
90 0.001 15
PS : Negative static pressure in inches water gauge.
120 0.013 21 N.C. : Noise Criteria

150 0.025 26 CONDITIONS


4 inch 180 0.036 32 * Return
* Noise Criteria is based on (10 dB) room attenuation.
210 0.048 37 * Damper is fully open.

240 0.060 43 * Data is based on 1ft length.

270 0.080 44
210 0.030 17
240 0.040 29
270 0.055 30
6 inch 300 0.070 34
330 0.085 33
360 0.105 37
405 0.140 40
240 0.020 15
270 0.030 16
300 0.040 34
8 inch 330 0.050 42
360 0.060 43
405 0.070 45
450 0.080 47
300 0.025 15
330 0.030 17
360 0.035 21
10 inch 390 0.040 37
405 0.045 43
450 0.055 40
480 0.065 56

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE