Technical Data Sheet for Surge Arrestors

330 KV SURGE ARRESTOR (SHERWOOD)


Item Particulars Unit Minimum Guaranteed
Requirements Particulars
8.1 GENERAL
8.1.1 Make Bidder to Supply
CG power and industrial
solutions limited
(Formerly Crompton
Greaves Limited)
8.1.2 Type Gapless Metal Station Class , GAPLESS ,
Oxide Metal Oxide
8.1.3 Service Outdoor Outdoor
8.1.4 System Earthing Effectively earthed Effectively earthed
8.1.5 Rated Voltage (Un) kV 330 330
8.1.6 Maximum System Voltage (Um) kV 362 362
8.1.7 Rated Frequency Hz 50 50
8.1.8 Prospective fault current kA 31.5 40kArms at 0.2 sec
8.1.9 INSULATION LEVEL
8.1.9.1 a) Power frequency withstand voltage - one kV rms Refer to Chpt 2, Sect 1 630
min
8.1.9.2 b) Lightning impulse withstand voltage kV peak Refer to Chpt 2, Sect 1 1425
8.1.9.3 c) Switching impulse withstand voltage kV peak Refer to Chpt 2, Sect 1 1050
8.1.10 Surge Arrestor Characteristics
8.1.10.1 Rated Voltage kV 264 264
8.1.10.2 Nominal Lightning Discharge Current kAp 20 20
(8/20µs)
8.1.10.3 Maximum residual voltage (Ures) at kV peak <700 700
20kA (8/20µs)
8.1.10.4 Maximum continuous operating Voltage kV ≥211 246
- MCOV (Uc)
8.1.10.5 Line discharge class Class 4 Class 4
8.1.10.6 Insulator material of arrester housing Composite Composite
8.1.10.7 Minimum Creepage Distance mm/kV 31 31
8.1.11 Accessories Required
8.1.11.1 a) Discharge Counter Yes Yes
8.1.11.2 b) Grading Rings Yes Yes
8.1.11.3 c) Insulating Base Yes Yes
8.1.12 Maximum steep fronted discharge voltage at kV peak Bidder to Supply 830
20kA
8.1.13 Cantilever strength of complete arrester Bidder to Supply 150
8.1.14 Leakage current at rated Voltage Bidder to Supply Less than 3mAp
8.1.15 Maximum radio interference voltage Bidder to Supply Less than 2500µV
8.1.16 Total mass of assembled unit kg Bidder to Supply 220kG (Approx)
8.1.17 Minimum expected life of arrester at yrs 25 As per IEC 60099-4
40°C and MCOV
Technical Data Sheet for Surge Arrestors
88 KV SURGE ARRESTOR (SHERWOOD)
Item Particulars Unit Minimum Guaranteed
Requirements Particulars
8.2 GENERAL
8.2.1 Make Bidder to Supply CG power and industrial solutions
limited (Formerly Crompton
Greaves Limited)
8.2.2 Type Gapless Metal Oxide Station Class , GAPLESS , Metal
Oxide
8.2.3 Service Outdoor Outdoor
8.2.4 System Earthing Effectively earthed Effectively earthed
8.2.5 Rated Voltage (Un) kV 88 88
8.2.6 Maximum System Voltage kV 100 100
(Um)
8.2.7 Rated Frequency Hz 50 50
8.2.8 Prospective fault current kA 25 40kArms at 0.2 sec
8.2.9 INSULATION LEVEL
8.2.9.1 a) Power frequency withstand kV rms 185 275
voltage - one min
8.2.9.2 b) Lightning impulse kV peak 450 650
withstand voltage
8.2.9.3 c) Switching impulse kV peak n/a na
withstand voltage
8.2.10 Nominal Lightning Discharge kAp 10 10
Current
(8/20µs)
8.2.11 Maximum residual voltage kV peak < 180 210
(Ures) at 10kA (8/20µs)
8.2.12 Maximum continuous kV >100 Ur - 84kV ; Uc - 72
operating Voltage - MCOV
(Uc)
8.2.13 Line discharge class Class 2 Class 3
8.2.14 Insulator material of arrester Composite Composite
housing
8.2.15 Minimum Creepage Distance mm/kV 31 31

8.2.16 Accessories Required


8.2.16.1 a) Discharge Counter Yes Yes
8.2.16.2 b) Grading Rings Yes NA
8.2.16.3 c) Insulating Base Yes Yes
8.2.17 Maximum steep fronted kV peak Bidder to Supply 235
discharge voltage at 20kA
8.2.18 Cantilever strength of Bidder to Supply 150
complete arrester
8.2.19 Leakage current at rated Bidder to Supply Less than 3mAp
Voltage
8.2.20 Maximum radio interference Bidder to Supply Less than 2500µV
voltage
8.2.21 Total mass of assembled unit kg Bidder to Supply 60kG (Approx)

8.2.22 Minimum expected life of yrs 25 As per IEC 60099-4


arrester at
40°C and MCOV
Technical Data Sheet for Surge Arrestors
132 KV SURGE ARRESTOR (ORANGE GROVE)
Item Particulars Unit Minimum Guaranteed
Requirements Particulars
8.3 GENERAL
8.3.1 Make Bidder to Supply CG power and industrial
solutions limited (Formerly
Crompton Greaves Limited)
8.3.2 Type Gapless Metal Station Class , GAPLESS , Metal
Oxide Oxide
8.3.3 Service Outdoor Outdoor
8.3.4 System Earthing Effectively earthed Effectively earthed
8.3.5 Rated Voltage (Un) kV 132 132
8.3.6 Maximum System Voltage (Um) kV 145 145
8.3.7 Rated Frequency Hz 50 50
8.3.8 Prospective fault current kA 25 40kArms at 0.2 sec
8.3.9 INSULATION LEVEL
8.3.9.1 a) Power frequency withstand kV rms 275 725
voltage - one min
8.3.9.2 b) Lightning impulse withstand kV peak 650 325
voltage
8.3.9.3 c) Switching impulse withstand kV peak n/a na
voltage
8.3.10 Nominal Lightning Discharge Current kAp 10 10
(8/20µs)

8.3.11 Maximum residual voltage (Ures) at kV peak < 350 340


10kA (8/20µs)

8.3.12 Maximum continuous operating kV >104 Ur - 120kV ; Uc - 102


Voltage
- MCOV (Uc)
8.3.13 Line discharge class Class 3 Class 3
8.3.14 Insulator material of arrester Composite Composite
housing
8.3.15 Minimum Creepage Distance mm/kV 31 31
8.3.16 Accessories Required
8.3.16.1 a) Discharge Counter Yes Yes
8.3.16.2 b) Grading Rings Yes Yes
8.3.16.3 c) Insulating Base Yes Yes
8.3.17 Maximum steep fronted discharge kV peak Bidder to Supply 380
voltage at 20kA
8.3.18 Cantilever strength of complete Bidder to Supply 150
arrester
8.3.19 Leakage current at rated Voltage Bidder to Supply Less than 3mAp
8.3.20 Maximum radio interference voltage Bidder to Supply Less than 2500µV

8.3.21 Total mass of assembled unit kg Bidder to Supply 120kG (Approx)


8.3.22 Minimum expected life of arrester yrs 25 As per IEC 60099-4
at
40°C and MCOV
Technical Data Sheet for Surge Arrestors
SURGE ARRESTORS – 33 KV (ORANGE GROVE – TO BE MOUNTED ON TRANSFORMER)
Item Particulars Unit Minimum Guaranteed
Requirements Particulars
8.4 General
8.4.1 Make Bidder to Supply CG power and industrial solutions limited
(Formerly Crompton Greaves Limited)
8.4.2 Type Gapless Metal Station Class , GAPLESS , Metal Oxide
Oxide
8.4.3 Service Outdoor Outdoor
8.4.4 System Earthing Effectively earthed Effectively earthed
8.4.5 Rated Voltage (Un) kV 33 33
8.4.6 Maximum System Voltage (Um) kV 36 36
8.4.7 Rated Frequency Hz 50 50
8.4.8 Prospective fault current kA 25 40kArms at 0.2 sec
8.4.9 INSULATION LEVEL
8.4.9.1 a) Power frequency withstand kV rms Refer to Chpt 2, Sect 1 70
voltage - one min
8. 4.9.2 b) Lightning impulse withstand kV peak Refer to Chpt 2, Sect 1 170
voltage
8. 4.9.3 c) Switching impulse withstand kV peak Refer to Chpt 2, Sect 1 na
voltage
8.4.10 Nominal Lightning Discharge Current kAp 10 10
(8/20µs)

8.4.11 Maximum residual voltage (Ures) at kV peak < 100 90


10kA (8/20µs)

8.4.12 Maximum continuous operating kV > 24 Ur - 30kV ; Uc -30


Voltage
- MCOV (Uc)
8.4.13 Line discharge class Class 2 Class 2
8.4.14 Insulator material of arrester housing Composite Composite

8.4.15 Minimum Creepage Distance mm/kV 31 31


8.5.16 Accessories Required
8.4.16.1 a) Discharge Counter Yes Yes
8.4.16.2 b) Grading Rings Yes NA
8.4.16.3 c) Insulating Base Yes Yes
8.4.17 Maximum steep fronted discharge kV peak Bidder to Supply 100
voltage at 10kA
8.4.18 Cantilever strength of complete Bidder to Supply 150
arrester
8.4.19 Leakage current at rated Voltage Bidder to Supply Less than 3mAp
8.4.20 Maximum radio interference voltage Bidder to Supply Less than 2500µV

8.4.21 Total mass of assembled unit kg Bidder to Supply 7kG (Approx)


8.4.22 Minimum expected life of arrester yrs 25 As per IEC 60099-4
at
40°C and MCOV