Beruflich Dokumente
Kultur Dokumente
en
Sandvik
Stationsplan, SE-233 81 Svedala, Sweden
Tel: +46 (0)40 409000, Fax: +46 (0)40 409260
www.sandvik.com
Appendix A:
Installation drawings
A.1 General
The following drawings show machine dimensions, connection positions and
dimensions, and access dimensions. All dimensions must be respected.
Dimensions are given in millimeters with inch dimension in brackets.
NOTE! The motor can be installed on either side of the crusher.
Crusher
H Over-pressure air Rp ¾" internal thread
I Lubrication oil to tank R 2"
K Lubrication oil from tank G 1½" B
L Hydroset G ¾" B
H G
F E
B
I D
K C
L
M R
N
O P Q
-PI1 Pressure gauge Hydroset pressure 100M20-2 0-6 MPa 923.0379-00 Tempress Hydroset system
-PI2 Pressure gauge Oil pressure (main) 2748 D63 0-1.6 MPa 923.0193-00 Wika Lubr. system
-LI1 Oil level indicator Oil level in tank (main) H00361-010 High/Low 914.0174-00 Parker Hannifin Lubr. system
-LI2 Oil level indicator Oil level in tank (Hydroset) H00361-007 High/Low 914.0170-00 Parker Hannifin Hydroset system
-B1N Position sensor Mainshaft position (HS-2800) EDS 160 0-160mm 984.0390-00 4-20mA Micro Epsilon ASRi
-B1N Position sensor Mainshaft position (HS-3800) EDS 250 0-250mm 984.0391-00 4-20mA Micro Epsilon ASRi
-B2N Press. transmitter Hydroset pressure 3376 0-250bar 923.0507-00 4-20mA Tecsis ASRi
-B3N Temp. transmitter Return oil temperature FLEXTOP PT-100 0-200°C 923.0489-00 4-20mA Bourdone Sed. ASRi
-U1N Power transducer Drive motor power draw P200-054 4-20mA Tillquist ASRi