Features
Ideal for use with 0-10V energy management systems, daylight
harvesting and local controls
Helps meet energy codes, including ASHRAE 90.1 and California
Title 24, when applied properly
Compatible with Energy-Saving and Low-Mercury Lamps
120-277V input for easy ordering and universal application
Dimming Range: 3% for T5/T5HO and T8
Programmed Rapid Start maximizes lamp life
End-of-lamp-life Shutdown circuit with Auto-reset for safe, long-
term operation
Active Power-factor Correction for maximum energy savings
Built-in line voltage protection
Starts at any dimmed level without flashing
Technical Data 0-10V Dimming 2-Lamp Specification-Grade Ballast
August 2014
Specifications Dimensions
(Inches/mm)
Starting Starting Method: Programmed Rapid-Start Case Type a
Start Time: Less than 700ms
Light Output Minimum: 0V
1.71 8.58
Maximum: 10 VDC
Lamp Crest 1.18
<1.7
Factor
THD <10% 9.50
8.90
Power Factor >0.98
Ballast Factor 1.0
Temperature Minimum Dimming Temperature: 50° F (10° C)
Energy Saving Lamps: 60° F (16° C)
Minimum Lamp Starting Temperature: 0° F (-18° C)
Maximum Ambient Temperature: 104° F (40° C)
Maximum Case Temperature: 167° F (75° C) Case Type D
Sounding Rating Class A
16.88
Dimensions Case A: 1.18"H x 1.71"W x 8.58"L 16.28
(30mm x43.5mm x 218mm)
Case D: 1.18"H x 1.25"W x 16.88"L 1.18
(30mm x 31.75mm x 428.75mm)
Wiring & Wiring: Control can be wired with Class I or Class II .26
Mounting Grounding: Ballast must be grounded in accordance
with national and local electrical codes 1.25 14.58
NNote:
• Use Purple (+) and Gray (-) for connection to 0-10 VDC.
• Wiring Purple and Gray together provides 3% light output.
• Capping Purple and Gray separately provides 100% light output.
2 www.coopercontrol.com
Technical Data 0-10V Dimming 2-Lamp Specification-Grade Ballast
August 2014
Dimming Curves
0% 0% 0%
0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10
Control Voltage (VDC) Control Voltage (VDC) Control Voltage (VDC)
Ordering
Catalog # Case Lamp Type Lamp Watt Lamp Lamp Voltage Input Input Input Ballast Dimming
Type Length Operation Watt Amps - Amps - Efficacy Performance
(FT) 120V 277V Factor -
120-277V
FLT-232PSUNVS010-R1-C-PK T8 40 4 71 0.59 0.25 1.24
T8 32 4 57 0.47 0.20 1.53
t8 28 4 49 0.40 0.17 1.81
T8 25 3 45 0.36 0.15 2.02
A Parallel 120-277 3%
T8 17 2 32 0.25 0.11 2.81
T8U 32 U 59 0.49 0.21 1.50
T8ES 32 (30) 4 55 0.44 0.19 1.61
T8ES 32 (25) 4 45 0.37 0.16 1.98
FLT-228PSUNVS010-R1-C-PK T5 28 4 64 0.55 0.23 1.59
T5 21 3 48 0.42 0.17 2.13
A T5 14 2 Parallel 120-277 34 0.29 0.12 3.03 3%
T5ES 28 (26) 4 59 0.52 0.22 1.75
T5ES 28 (25) 4 59 0.51 0.21 1.75
FLT-254PSUNVS010-R1-C-PK T5H0 54 4 116 0.94 0.41 0.89
D FT55W 55 4 109 0.88 0.38 0.86
Parallel 120-277 3%
FC55T5H0 55 4 105 0.83 0.38 0.87
T5H0ES 54 (49) 4 102 0.89 0.37 0.99
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
© 2014 Eaton
All Rights Reserved Eaton is a registered trademark.
Printed in USA
Publication No. ACC140050 All other trademarks are property
August 21, 2014 of their respective owners.