Sie sind auf Seite 1von 8

Datos de los componentes

 UJT

𝑈𝑗𝑡 𝑄1 202646 𝑢𝑗𝑡


0.56 ≤ 𝑛 ≤ 0.75
𝑉𝐵𝐵𝑚𝑎𝑥 = 35𝑣
𝐼𝑣 = 4𝑚𝑣
𝐼𝑝 = 5𝑢𝐴
4.7 𝑘Ω ≤ RBB ≤ 9.1 𝑘Ω
𝐼𝐸𝐵1 = 50𝑚𝐴

 Transistor

𝐵𝑗𝑡 𝑄2 203906 𝐵𝐽𝑇


𝐼𝐸𝑚𝑎𝑥 = 200𝑚𝐴
𝑉𝐸𝐶𝑚𝑎𝑥 = 40𝑣

 Tiristor

𝐵𝑇136 𝑇𝑅𝐼𝐴𝐶
𝑉𝐺𝑇 = 1.5 𝑣
𝐼𝐺𝑇 = 30𝑚𝐴

 Transformador

𝑣𝑝 127
𝑁= =
𝑣𝑠 12
𝑓 = 60 𝐻𝑧
Desarrollo:

𝑉𝑣 < 𝑉𝑍1 < 𝑉𝐵𝐵𝑚𝑎𝑥

𝑉𝑍1 = √2𝑉𝑠

𝑉𝑍1 = √2 (12)
𝑉𝑍1 = 16.97 𝑉
𝑉𝑣 ≈ 2𝑣 𝐸𝑥 𝐸𝑚𝑝
2𝑣 < 16,97𝑣 < 35𝑣
𝐴𝑠𝑢𝑚𝑜 𝐸𝑠𝑡𝑎𝑛𝑑𝑎𝑟 𝑉𝑧1 = 12𝑣
𝑉𝑝 = 𝑣𝑥 + 𝑣𝐷
𝑉𝐷 = 0.5 𝑣 𝐸𝑥 𝐸𝑚𝑝
𝑅𝐵1 + 𝑅𝑜
𝑉𝑥 = 𝑉𝑧1
𝑅2 + 𝑅𝐵2 + 𝑅𝐵1 + 𝑅𝑜
𝑅𝐵1 + 𝑅𝑜
= 𝑉𝑧1
𝑅2 + 𝑅𝐵2 + 𝑅𝐵1 + 𝑅𝑜
𝑅𝑂 ≪ 𝑅𝐵𝐵, 𝑅2
𝑅𝐵1
= 𝑉𝑧1
𝑅2 + 𝑅𝐵𝐵
𝑛 𝑅𝐵𝐵
= 𝑉𝑧1
𝑅2 + 𝑅𝐵𝐵
0.75 + 0.56
𝑛= = 0.655
2
9.1𝐾 + 4.77
𝑅𝐵𝐵 = = 6.9𝑘Ω
2
2𝑘Ω < 𝑅2 < 3𝑘Ω
𝑅2 = 2.7𝑘Ω EFECTOS TERMICOS
12𝑉 ∗ 0.655 ∗ 6.9𝑘Ω
=
2.7𝑘Ω + 6.9𝑘Ω
= 5.65𝑉
𝑉𝑝 = 0.5𝑣 + 5.65𝑣
= 6.15𝑣
Para trabajar en zona Activa

𝑉𝐸𝐶 ≥ 3𝑉
𝑉𝐸 = 𝑉𝑃 + 𝑉𝐸𝐶
𝑉𝐸 = 6.15 𝑉 + 3𝑉
𝑉𝐸 = 9.15𝑉
𝑉𝑅𝑇𝐸 = 𝑉𝑍1 − 𝑉𝐸
𝑉𝑅𝑇𝐸 = 12𝑉 − 9.15𝑉
𝑉𝑅𝑇𝐸 = 2.85𝑉
𝑉𝑍2 = 𝑉𝑅𝐸𝑇 + 𝑉𝐸𝐵
𝑉𝑍2 = 2.85𝑉 + 0.7𝑉
𝑉𝑍2 = 3.55𝑉 … . . 𝐷𝐸 3,6 𝑉 𝑂 3.3𝑉
ELEJIMOS VZ2=3.3V

𝑉𝑅𝑇𝐸 = 𝑉𝑍2 − 𝑉𝐸𝐵


𝑉𝑅𝑇𝐸 = 3.3𝑉 − 0.7𝑉
𝑉𝑅𝑇𝐸 = 2.6𝑉
𝑉𝐸 = 𝑉𝑍1 − 𝑉𝑅𝑇𝐸
𝑉𝐸 = 12𝑉 − 2.6𝑉
𝑉𝐸 = 9.4𝑉

𝑉𝐸𝐶 = 𝑉𝐸 − 𝑉𝑃
𝑉𝐸𝐶 = 9.4𝑉 − 6.15𝑉
𝑉𝐸𝐶 = 3.25𝑉

𝑉𝐸𝐶 = 3.25𝑉
𝑉𝐸𝐶 ≥ 3𝑉
3.25 ≥ 3𝑉
𝑇 180° → 8.33𝑚𝑠
𝑇 10° → 𝑥
𝑥 = 0.4627𝑚𝑠
Asumo c=0,1 uf
6.15𝑉
𝐼10° = 0.1𝑢𝐹
0.4627𝑚𝑠
1.33𝑚𝐴

6.15𝑉
𝐼𝜋 = 0.1𝑢𝐹
8.33𝑚𝑠
𝐼𝜋 = 73.83 𝑢𝐴
𝐼𝑝 < 𝐼10° < 𝐼𝑣
5𝑢𝐴 < 73.83𝑢𝐴 < 4𝑚𝐴
𝑅𝑇10° = 𝑅𝑇𝐸𝑚𝑚
𝑉𝑅𝑇𝐸
𝑅𝑇𝐸𝑚𝑚 =
𝐼10°
2.6𝑣
𝑅𝑇𝐸𝑚𝑚 =
1.33𝑚𝐴
𝑅𝑇𝐸𝑚𝑚 = 1.95𝐾Ω
𝑅𝑇𝐸𝜋 = 𝑅𝑇𝐸𝑚𝑥
𝑉𝑅𝑇𝐸
𝑅𝑇𝐸𝑚𝑥 = 𝐼𝜋
2.6𝑣
𝑅𝑇𝐸𝑚𝑥 =
73.83𝑢𝐴
𝑅𝑇𝐸𝑚𝑥 = 35.22𝐾Ω
𝑅𝑇𝐸 = 𝑃𝐸 + 𝑅𝐸
𝑉𝑍1
𝑅. 𝐸. 𝑚𝑖𝑛 =
𝐼𝐸𝑀𝑋
𝐼𝑍𝑉
=
200 𝑀𝑃
= 60 Ω
𝑅𝐸𝑚𝑖𝑛 < 𝑅𝐸 < 𝑅𝑇𝐸10°
= 60 Ω < 𝑅𝐸 < 1.95𝐾2
Asumo RE = 1KΩ
𝑉𝑍1 12𝑉
𝐼𝐸 = =
𝑅𝐸 1𝐾Ω
= 12𝑚𝐴
𝐼𝐸 < 𝐼𝐸𝑚𝑥
12𝑚𝐴 < 200𝑚𝐴
𝑃𝐸 > 𝑅𝑇𝐸 𝜋
𝑅𝑇𝐸 = 𝑃𝐸 + 𝑅𝐸
𝑃𝐸 = 𝑅𝑇𝐸𝜋 − 𝑅𝐸
= 35.22𝐾Ω − 1KΩ
= 34,22𝐾Ω

 50𝐾Ω
 10KΩ
𝑃𝐸 = 50𝐾Ω ESTANDAR
50𝐾Ω > 35,22KΩ
𝑖𝑅 = 𝑖𝑍2 + 𝑖𝐵
𝑖𝐵𝑙𝑙𝑖𝑅. 𝑖𝑍2
𝑖𝑅 = 𝑖𝑍
𝑃𝑧 = 𝑉𝑍2 𝐼𝑍2𝑚𝑥
𝑃𝑍
𝐼𝑧2𝑚𝑥 =
𝑉𝑍2
1/4𝑤
=
3,3𝑉
= 75,75𝑚𝐴
𝐼𝑍𝑇2´ = (0,6)𝐼𝑍𝑍𝑚𝑥
𝐼𝑍𝑇2´ = (0,6)(75,75)𝑚𝐴
𝐼𝑍𝑇2´ = 45,45 𝑚𝐴
𝐼𝐸 𝐼10°
𝐼𝐵 = =
𝐵 𝐵𝑚𝑛
1,33𝑚𝐴
𝐼𝐵 =
80
𝐼𝐵 = 16,62𝑢𝐴
𝐼𝐵 ≪ 𝐼𝑍𝑇2¨
16,16𝑢𝐴 ≪ 45,45𝑚𝐴
𝑉𝑍1 − 𝑉𝑍2
𝑅=
𝐼𝑍𝑇2¨
12𝑉 − 3,3𝑉
𝑅=
45,45𝑚𝐴
𝑅 = 191,41Ω

 220Ω
 180Ω
𝑅 = 220Ω (Estandar)
𝑃𝑎𝑟𝑎 𝑞𝑢𝑒 𝑝𝑎𝑠𝑒 𝑚𝑒𝑛𝑜𝑠 𝐼𝑍𝑇2¨
𝐼𝐸𝐵1 < 50𝑚𝐴
𝐼𝑅𝑜 = 𝐼𝐸𝐵1
𝑉𝑃 − 𝑈𝑉
𝑃𝑜𝑚𝑛 =
𝐼𝑅𝑜
6,15𝑉 − 2𝑉
𝑃𝑜𝑚𝑛 =
50𝑚𝐴
𝑃𝑜𝑚𝑛 = 82 Ω

 120Ω
 75Ω

𝑅𝑜 = 120Ω
𝑉𝑃 − 𝑉𝑣
𝐼𝐸𝐵1 =
𝑅𝑜
6,15𝑉 − 2𝑉
𝐼𝐸𝐵1 =
120Ω
𝐼𝐸𝐵1 = 34,58𝑚𝐴
34,58𝑚𝐴 < 50𝑚𝐴
𝑉𝑅𝑆
𝑅𝑆 =
𝐼𝑅𝑆

𝑅𝑆 = 𝑅𝐷 − 𝑍𝐼
𝛼 𝜋
𝛿= = =1
𝑇 𝜋

𝐷𝐷 = 𝐴𝛿

𝐷𝐷 = 12√2 − 2

𝐷𝐷 = 14,97𝑉 ≈ 15𝑉

𝑍1 = 𝐴𝛿

𝑍1 = 12(1)

𝑍1 = 12

𝑅𝑆 = 15𝑉 − 12𝑉
= 3𝑉
𝐼𝑅𝑆 = 𝑖𝑍1 + 𝑖𝐴𝑢
𝑉𝑍1
𝑖𝐴𝑙𝑙 = 𝐼𝑍𝑇𝑍¨ + 10° +
𝑅2 + 𝑅𝐵𝐵 + 𝑅𝑜
12
= 45,45𝑚𝐴 + 1,33𝑚𝐴 +
2,7𝐾 + 6,9𝐾 + 120
= 45,45𝑚𝐴 + 1,33𝑚𝐴 + 1,23𝑚𝐴
= 48,01𝑚𝐴
𝑃𝑍1 1/2𝑤
 𝑖𝑍1 = 𝑉𝑍1 = 12𝑉
= 41,67𝑚𝐴

𝐼𝑍𝑇1´ = 0.6(41,67𝑚𝐴)
= 25𝑚𝐴
𝑃𝑍1 1𝑤
 𝑖𝑍1 = 𝑉𝑍1 = 12𝑉 = 83,3𝑚𝐴

𝐼𝑍𝑇1´ = 0.6(83,3𝑚𝐴)
= 49,98 𝑚𝐴 ≈ 50𝑚𝐴
𝐶𝑂𝑁 𝑃𝑍1 = 1𝑊 𝐶𝑂𝑀𝐸𝑅𝐶𝐼𝐴𝐿
𝑉𝑅𝑆
𝐼𝑅𝑆 =
𝐼𝑍𝑇𝑖 + 𝐼𝑍𝑇2´
3𝑉
𝐼𝑅𝑆 =
50𝑚𝐴 + 45,45𝑚𝐴
𝐼𝑅𝑆 = 31,43 Ω
 43Ω
 30Ω
𝑅𝑆 = 30Ω PARA QUE EXISTA MIN. CORRIENTE
𝑉𝑃 − 𝑉𝑣 − 𝑉𝐺𝑇
RE =
𝐼𝐺𝑇
6,15𝑉 − 2𝑉 − 1,5𝑉
RE =
30𝑚𝐴
RE = 88,33 Ω

 100Ω
 82Ω
RE = 82Ω ESTANDAR
SIMULACIONES

Ilustración 1 simulacion circuito de relajacion con el Triac en proteus


Ilustración 2 Disparo del tiristor

Ilustración 3 señal en la carga

Recomendaciones
 Para observar bien las oscilaciones es recomendable adquirir un
osciloscopio con alta definición al mismo tiempo en el circuito usar leds
para verificar la variación de la frecuencia.
 Llevar obligatoriamente protección en la carga para evitar los
cortocircuitos.
 Evitar el uso indebido de las herramientas del laboratorio.

Das könnte Ihnen auch gefallen