Beruflich Dokumente
Kultur Dokumente
System Overview
?
C C C
B B B B
A A A A A
Local control room Central control room Engineering Local control room
SIMATIC PCS 7
PROFIBUS DP SIPART DR
SIMATIC
S7/M7-300
SIWAREX M
P R O C E S S F IE L D B U S
PROFIBUS PA SIMOVERT
MASTERDRIVES
MICROMASTER
E /R
M o du l
SITRANS P
SIMODRIVE
POSMO 1FT6/1FK6
SIMATIC
Database Communicatio
n
Data Management
Software
Communication
HMI SCADA
SPS Controller
Field
TIC
TIC
TIC
TI
C
TI
C
TIC
SF
C
?
COROS OP45
WinCC
C C C
B B B B
A A A A A
PC
?
C C C
PLC PCS B B
PLC
B B
A A A A A
?
PC
PLC PLC
B B B B
PCS A A A A A
Automation
technology
AS
• Measurement
• Closed-Loop Con.
• Open-Loop Con.
etc.
HMI
•Displaying
•Operating
•Logging
OS
+ etc.
Communication
technology Bus
SIMATIC PCS
SIMATIC S5/COROS
SIMATIC Controllers
S7 200 S7 300
+
S7 400 SIMATIC M7
SIMATIC C7
S
0
1
2
•
3
0
1
2
3
4
5
• Ex(i) modules
0
1
2
3
4
5
6
7
0
1
•
2
Ind. Ethernet
SIMATIC Distributed I/O - ET 200M
Standard I/O modules
Intrinsically safe modules [EEx ib] AS 414, AS 416, AS 417
Function modules
ET 200 M
Properties ET 200M
Up to 8 modules per station
PROFIBUS DP
Up to 61 analog values per station
High channel density and functionality ET 200 M
[EEx ib]
Removing and connecting modules
possible during operation
Degree of protection IP 20 Field
devices
Ind. Ethernet
AS 414 H
AS 417 H
PROFIBUS-DP
I/O module
sensor
redundant
I/O module
DI 14 x DC24 V (6ES7326-1BK00-0AB0)
DI 8 x NAMUR [EEx ib] (6ES7 326-1RF00-0AB0)
F-DO F-DO
DI DI
standard ET200M line:
DI 16 x DC24V, Diagnosis (6ES7 321-7BH00-0AB0)
DO DO
AI-U AI-U
Rail
ET 200 M
Power supply:
DC 24 V single / redundant
230 VAC
SIMATIC HMI
WinCC
Windows
Control Center
WinCC
Open for
PC other
n
base PLC systems Ope itecture
arch
Scalable Standard
Easy interface Price
to Operator
use with System
options
SIMATIC NET
ES
OS OS
P R O C E S S F IE L D B U S
AS-Interface
Master Master
(Class 1) (Class 2)
PROFIBUS DP
PROFIBUS PA
Slaves
(Field devices, distributed I/Os, lower-level PLCs,
network transition to PROFIBUS PA)
Operator Interface
X Engineering Station
W
CC
IN
OS ES
CC
Communication
Et
h er
n et
S7
IC
M AT
Controller
SI
High availability
High quality
Standard SIMATIC components
Short MTTR
Diagnostics functions
Removing/inserting under power
Process control message concept
Redundancy
CPU
Module
Communication
Grundzustand P-AUSGL. AB FR
V2
F1
V5 P5 0000.0 MBAR
R1 ABLUFT2
0000.0
PC V3
0000.0 MBAR
V6 P6 0000.0 MBAR
ABLUFT3
A1 0000.0 %
Reaktor 01
M1
produkt
M
ES
HT FO AU AS HD FR FW VORBEREITEN/STARTEN
Engineering
System
OLE
ODBC / DDE
File transfer
Cornerstone OS HC ES
C C C
B B B B
A A A A A
WIN CC
Ind. Ethernet
Engineering
SIMATIC S7
PROFIBUS
Instrum. Drives
M
‘System-wide IT
IT
‘Intranet / Internet’
engineering’ ES
ES OS
OS
OS client , OPC, at@Glance,
SPC, MES, ERP etc.
• OS
•Batch
•AS and SPSen
‘System bus’
•industrial Ethernet and
•Remote I/O ‘ET200…’
100 Mbit/s high-speed Fast Ethernet ring
•Networks
•fully redundant
•FB library incl.
•field-proven (since 1996)
- PROFIBUS devices
- SIMOVERT
- SIMOCODE
- MicroMaster
10/100 Mbit/s
PLC
PLC
Ident. components
& software tools!
- ...
- SIPART
AS
AS
- SIPOS HART
- SITRANS Remote
Remote
‘H2’ fieldbus I/O
- SIWAREX I/O M
‘PROFIBUS DP‘ 12 Mbit/s
- S5-95F ‘failsafe’
•high-speed ...
...
- AS-interface & link DP/PA
DP/PA
31,25 kbit/s ‘H1’ fieldbus
•fully redundant
-…
bus and ring PA
PA PA
PA PA
PA
‘PROFIBUS PA‘
• • intrins. safe/ Exi
For more information about
field-proven 12 Mbit/s
• bus-supplied devices
drivers, go to e.g.: (since 1992) M PID
PID • field-proven (since 1997)
http://intra1.khe.siemens.de/~infopage/ •IEC 61158
DP
• IEC 61158
95F
95F AS
...
A
A S
S ...
PROFIBUS-
PROFIBUS-
HART P
PROFIBUS-
ET 200M DP/PA-Link
PROFIBUS-
PROFIBUS-PA
DP/EI PA
B DP/PA-Link Y-Link
DP
DP
DP/PA-Link
DP
PROFIBUS- PROFIBUS-PA
ET ET DP ET
200 200 200iS COx,
Zone 1
X S NOx, ..
Zone 2
.