Beruflich Dokumente
Kultur Dokumente
V100R010
IDU Quick Installation Guide for Outdoor
Cabinets
(OMB Cabinets)
Issue: 01
Date: 2017-05-30
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Personnel Safety
The high-voltage power supply provides power for running the system. Avoid direct contact with the high-voltage
power supply or contact through damp objects. Failure to do so causes serious injury or death.
Non-standard and incorrect operations on the high-voltage power supply may result in fire and electric shock.
Do not perform operations on high-voltage and AC power supply facilities or on a tower or mast in the case of
thunderstorm. Failure to do so causes serious injury or death.
Ground the device before powering it on. Failure to do so causes damage to the device or personal injury.
Power off the device before performing operations on the power supply facilities.
Personnel Safety
High power radio-frequency signals are harmful to the human body. Ensure that the transmitter antennas are
muted before installing or maintaining an antenna on a tower or mast that holds a large number of transmitter
antennas.
Do not stand close to, or look into the optical fiber outlet without eye protection when handling optical fibers.
Take preventive measures when drilling holes. Otherwise, dust may hurt your eyes or you may inhale the dust.
Power off the batteries before connecting the cables to the batteries. Failure to do so causes personal injury.
When working at heights, be cautious about falling objects.
Device Safety
Check the electrical connection of the device before operation and ensure that the device is securely grounded.
The static electricity discharged from the human body may damage the electrostatic sensitive components, such
as large-scale integrated circuits (LSIs), on the circuit board. Wear an ESD wrist strap or ESD gloves when
handling a circuit board.
1
Instructions and Precautions for Handling Boards
CAUTION
Do not hold a board without hand protection. Wear an ESD wrist strip or ESD gloves before handling a board.
Wearing ESD gloves Wearing an ESD strip Holding a board without hand protection
CAUTION
Hold the front panel of a board with hands.
CAUTION
Insert filler panels into vacant slots on an NE to prevent foreign matters from getting into the NE, which
may result in faults on the NE.
Boards are fragile and valuable. When handling or placing a board, exercise caution and put it into a
dedicated packing box.
2
Instructions and Precautions for Handling Power Cable
Terminals
1
2
1
2
1 2
1 Press the front of the red latch. 2 Properly move the red latch outwards.
CAUTION
Do not pick up the tail end of the red latch by using a finger or a screwdriver to avoid damage.
3
Tools for Installation
Long measuring tape Level Phillips screwdriver Flat-head screwdriver Adjustable Wrench
Socket wrench Torque wrench Hex key COAX crimping tool Wire clippers
Wire stripper RJ45 crimping tool Diagonal pliers Cold press pliers Needle-nose pliers
ESD gloves ESD wrist strap Ladder Electric iron Impact tool
Vacuum cleaner Binding strap Insulation tape Coax stripper Network cable tester
4
Introduction to the Equipment
10 11 12
NM/COM port Ethernet service port ESD port 12 ODU power switch
NOTE
Based on different board configurations, the positions of the actual IDU ports may be different from the
positions shown in the figure.
5
2 Introduction to the OMB Cabinet
a Front View of the OMB Cabinet
Technical Specifications
Dimensions (mm): 600 (H) x 240 (W) x 430 (D)
Ambient temperature (no sunshine radiation): -20°C to
+50°C
b Left View of the OMB Cabinet c Right View of the OMB Cabinet
6
d About the Internal Structure of the OMB Cabinet
HEUA
PMU module
HEUA
DCDU-03B
Cable trough
7
Installation Scenarios of the Cabinets
m
0m 390 m
24 m
600 mm
b c
Recommended Requirements Minimum Requirements of the
of the OMB Cabinet OMB Cabinet
≥200 mm ≥200 mm
m m
0m 0
m
30 15
≥ ≥
≥80 ≥6
0 mm 00 m
m
≥600 mm ≥500 mm
8
d Installation Modes
Installing the OMB cabinet on a pole Installing the OMB cabinet on a wall
NOTE
The OMB cabinet provides a small space. Therefore, it is not recommended that you use the OMB cabinet in
an area where the ambient temperature is lower than –20°C in winter. It is recommended that you use the
APM30H or TMC11H cabinet that is configured with a heater.
Determine the position of the backplane on the wall, and Drill the holes and install the expansion bolt assembly.
mark the four anchor points by using a marker.
Bolt M10x75
Spring washer 10
Plastic tube
φ14 Flat washer 10
210mm 。 Expansion bolt
90
55~60mm
378mm
378mm
3
5 6
4 20~30mm
m
210m
9
Install the backplane of the OMB frame on the wall.
M6 screw
Install the first upper fastener assembly on the pole. Install the lower fastener assembly on the backplane.
Flat washer
Spring washer
M10x180 bolt
M10x40 bolt
10
Install the backplane on the pole.
11
Outdoor Pole-Mounting Scenario
b Installing the RTN 950A in the OMB Cabinet (DC Power Supply)
12
Installing the Assemblies
Fan assembly
CAUTION
When installing the RTN 950A, ensure that the fan assembly is installed in the lower part of the cabinet.
When being installed in the AC or DC powered OMB cabinet, the RTN 950A can work as only a
repeater. When using service cables such as E1 cables and Ethernet cables, install the RTN 950A in
the APM30H or TMC11H cabinet.
13
Installing and Routing the Cables
NOTE
When installing the PGND cables in the DC powered
OMB cabinet, use the same method as that in the AC
powered OMB cabinet.
Ground bar
14
2 Installing and Routing the Power Cables – AC Power Supply
a Installing the Input Power Cable for the OMB Cabinet (AC Power Supply)
a N
L PE
For AC OMB cabinets of Ver. C, connect the two power cables from
RTN 950A to any two power output terminals (such as terminals
LOAD6 and LOAD7) with the maximum output current of 30 A. For
information about assembling the easy power receptacle (pressfit type)
connector, see "Appendixes."
15
3 Installing and Routing the Power Cables – DC Power Supply
a Installing the Input Power Cable for the OMB Cabinet
RTN
(+)
NEG
(-)
For AC OMB cabinets of Ver. C, connect the two power cables from
RTN 950A to any two power output terminals (such as terminals
LOAD6 and LOAD7) with the maximum output current of 30 A. For
information about assembling the easy power receptacle (pressfit type)
connector, see "Appendixes ".
16
4
Installing the Service Cables for the Equipment – AC Power
Supply
a Installing IF Cables
Rubber block
b Installing Fibers
Binding strap
Insulation tube
17
c Installing Signal Monitoring Cables
CSH
PROG
SYNC
SRV
ACT
STAT CF RCV RST NMS/COM EXT CLK/TOD1 TOD2
TOD2 port
NOTE
When using the CSHO board, connect the signal monitoring cable to the MON/TOD2 port.
RJ-45 Connector of the Network Port to the RJ-45 Connector (TOD2) of the Network Port to
Cable on the CMUA (COMIN) Board the Cable on the CSH/CST Board
87654321
Pin 1 TX+ White/Orange Pin 6 RX+ White/Orange
No No
Pin 3/6/7 - Pin 1/2/4 -
connected connected
18
5
Installing the Service Cables for the Equipment – DC Power
Supply
a Installation Effectiveness of the Service Cables
19
Checking the Installation
2 In pole-mounting mode, the mounting brackets are fixed securely, and the frame is fixed properly
and is not distorted.
3 In wall-mounting mode, the holes for the frame are in proper contact with the holes for the
expansion bolt, and the frame and the wall surface are in proper horizontal contact.
4 In wall-mounting mode, the cabinet is installed securely and does not swing when you shake it.
5 The waterproof cover of the bottom port and the hang chains are bound with the surrounding
cables.
6 The surface of the overall equipment is clean and tidy. The exterior paint is intact.
8 All labels, tags, and nameplates are correct, legible, and complete.
3 No tapes, cable ties, wastepaper, or packing bags are left around the equipment cabinet.
4 All the items around the equipment are neat, clean, and intact.
20
3 Checking Electrical Connections of the Cabinet
No. What to Check For
1 All the self-made PGND cables are copper-based with proper wire diameters. There is no
switch, fuse, or short circuit on the cable.
2 According to the wiring diagram of the power system, the PGND cables are connected securely,
the AC lead-in cables and cables inside the cabinet are connected properly, and the screws are
tightened. Ensure that the output and input cables are not short-circuited.
3 The redundant part of the power cable or PGND cable is stripped off rather than being coiled.
4 The lugs at both ends of the power cable or PGND cable are soldered or crimped securely.
5 Bare wires and lug handles at the wiring terminals are wrapped tightly by using insulation tapes
or heat shrink tubes.
6 The flat washers and spring washers are mounted securely to all the wiring terminals.
7 The connectors of all cables are securely linked, especially those at the bottom of the cabinet.
8 The cables are properly bound. Cable ties are installed at equal spacing and in the same
direction.
9 The power cable and PGND cable are routed separately from other cables.
12 The excess of cable ties is trimmed off without remaining rough edges.
21
Appendixes
Power input cable of an AC/DC Right cable hole Select any one.
cabinet
For cabinets of Ver. C, the number
of cable holes is increased from 4
to 6. Select cable outlets based on
requirements.
General ground cable of an AC/DC Right cable hole
cabinet
22
2 Installing the Cables on the Cable Module
Remove the screws from the cable Route the cable from the bottom of the cable trough
upwards through the corresponding cable hole on the cable
module.
module, and ensure that the cable connector is idle.
After routing all the cables through the cable hole on the
waterproof cable module, connect the cable connector to
the corresponding port on the equipment.
NOTE
For information about the position of the cable holes,
cable routes, and installation methods, see the
description of the installation procedure.
23
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Industrial Base Bantian Longgang
Shenzhen 518129
People’s Republic of China
www.huawei.com