Multifunction Relay Platform - AEGIS

Transformer Protection Relay

Feeder Protection Relay Transformer Protection Relay

Product Overview
The Aegis range of multifunction relay platform provides cost
effective, integrated Numerical Protection, Control, Monitoring IEC 61850
&Measuring functions with Communication functionality. The platform Communication
has state of-the-art technology which ensures superior performance. Protocol
It can be used for the protection of High and Medium voltage Compliant
networks.

Salient Features :
4
For easy adoption to varying system operating conditions four Applications :
independent setting groups are provided.
Feeder Protection Relay
4
Suitable for both 1A & 5A CT configuration on same terminals.
4
Main or backup protection on MV&HV systems.
4
Graphical LCD with 160*160 dots display to view the Relay
features, System Voltages, Currents phase angles. 4
Comprehensive protection for distribution feeders.
4
Self monitoring & PSL Logic.
4
Capacitor banks, reactors protection based on the neutral current
4
After a network fault the relays support a subsequent fault analysis and Residual voltage detection principle.
by providing event sequence recordings, fault value registration Motor Protection Relay
and disturbance recorder capability.

4
Exclusive storage of 500 sequences of events. 4
Wide range of protection for a synchronous motor.

4
Storage of latest 10 fault records. 4
Medium size and large size rotating machines.
4
Storage of latest 15 disturbance records. Transformer Protection Relay

4
Closing & Tripping command to breaker from the relay. 4
Differential protection with dual slope characteristics used for the
4
Configurable & Programmable digital outputs and digital inputs. protection of two winding distribution power transformer.

4
Front USB port for local communication and for Relay configuration 4
Other than differential remaining protections can be used as
software interaction with PC. backup protection.
Multifunction Relay Platform AEGIS Series

PROTECTION FUNCTIONS
ANSI No. Function Name Feeder Motor Transformer
50/51 Instantaneous and Inverse time phase over current protection ? ? ?
51,51N Instantaneous and Inverse time Earth fault protection ? ? ?
67 Directional Instantaneous and Inverse time phase over current protection ?
67N Directional Instantaneous and Inverse time Earth fault protection ?
27 Instantaneous and Inverse time phase under voltage protection ? ? ?
59 Instantaneous and Inverse time phase over voltage protection ? ? ?
59N Neutral Displacement Protection ? ? ?
46 Phase unbalance Protection ? ? ?
50BF Circuit Breaker failure Protection ? ? ?
46BC Broken conductor detection Protection ?
68 Cold load Pickup & Inrush ?
51V Voltage Controlled Over Current ? ?
32 Reverse Power Protection ? ?
40 Loss of Excitation ? ?
79 Auto Reclose ?
49 Thermal Overload Protection ?
51LR Stall Protection ?
46R Phase Reverse Protection ?
37 Under Current Protection ? ?
87T Biased Differential – Two Winding ?
87T HS High Set Differential ?
87NH High Impedance REF ?
49T Three Phase Thermal Overload ?
81HBL2/4/5 Inrush Detector (2 ,4 & 5 Harmonic Blocking)
nd th th
?
24 Over Fluxing ?
81 Under/Over Frequency ?
MEASUREMENTS & MONITORING FUNCTIONS
60CTS CT Supervision ? ? ?
PTFF Supervision ? ?
74TCS Trip Circuit Supervision ? ? ?
Three Phase Current ? ? ?
Neutral current ? ? ?
Sequence Components of Currents ? ? ?
Sequence Components of voltages ? ?
Phase to earth, Phase to Phase Voltage ? ?
Phase Angle ? ?
55 Power factor ? ?
Active Power ? ?
Reactive Power ? ?
Apparent Power ? ?
Energy Measurement ? ?
2nd to 15th harmonic and THD of Currents ? ?
2nd to 15th harmonic and THD of Voltages ? ?
Phasor diagram of Voltages ? ?
Phasor diagram of Currents ? ?
Frequency ? ?
Actual RMS value of Currents ? ?
Actual RMS value of Voltages ? ?
Motor Start up Protection ?
COMMUNICATION
IEC 60870-5-103 ? ? ?
Modbus ? ? ?
IEC61850 ? ? ?
DNP3.0 ? ? ?
Function Overview Diagram:
Multifunction Relay Platform
AEGIS Series

TRANSFORMER PROTECTION RELAY MOTOR PROTECTION RELAY FFEDER PROTECTION RELAY


Multifunction Relay Platform AEGIS Series

Ordering Information for AEGIS Series Protection Relays


AEGIS
FEEDER PROTECTION RELAY
Three Phase O/C & E/F (50/51/50N/51N) F
Three Phase Directional O/C & E/F (67/67N)
Three Phase O/V, U/V & NDR (27,59,59N)
Negative Phase Sequence (46)
Cold load Pick up & Inrush
CBFP (50BF) , Broken Conductor (46BC)
VTFF (97) & CT Supervision (60CTS)
MOTOR PROTECTION RELAY
Three Phase O/C & E/F (50/51/50N/51N) M
Thermal overload protection (49M)
Three Phase O/V, U/V & NDR (27,59,59N)
Negative Phase Sequence (46)Phase Reversal(46R)
Stall Protection (51LR)
CBFP (50BF), Under Current Protection(37)
VTFF (97) & CT Supervision (60CTS)
TRANSFORMER PROTECTION RELAY T
Three Phase O/C & E/F (50/51/50N/51N)
Biased Differential (87T)
O/V, U/V & NDR (27,59 ,59N)
Negative Phase Sequence (46)
Inrush Detector (2nd , 4th & 5th -Harmonic Blocking ) (81HBL2/4/5)
CBFP (50BF)
CT Supervision (60CTS)
Thermal protection(49)
Over fluxing(24)
Under Current (37)
REF (87NH)
Under & Over frequency (81)
COMMUNICATION
IEC 60870-5-103 on RS-485 1
MODBUS RTU on RS-485 2
IEC 60870-5-103 on Fiber Optic 3
DNP3 on RS485 4
Modbus TCP/IP on Ethernet RJ45 5
IEC61850 on Ethernet RJ45 6
IEC61850 on Fiber optic 7
IEC61850 ON RJ45 + IEC103 on RS485 8
IEC61850 ON Fiber Optic + IEC103 on Fiber Optic 9
DIGITAL INPUTS & DIGITAL OUTPUTS
4DI + 8DO 1
8DI + 12DO 2
10DI + 10DO 3
12DI + 8DO 4
4DI + 16DO 5
AUXILIARY POWER SUPPLY
18-52VDC 1
75-250VDC 2
Crompton Greaves Ltd.,
Power Systems : M. V. Switchgear Division (S2)
A-3, MIDC, Ambad, Nasik - 422 010. India.