Sie sind auf Seite 1von 2

Rain Load

Reference
Design for Rain Loads
References are
to ASCE 7-10

Ref. Arch sheet


Data : 100 year, 1 hour rainfall : 4.7 inches

dh is calculated by interpolation from table C8-1,ASCE 7-10. The scupper width measured fromarchitectural
drawings 16".

2
Roof area serviced by a single drainage system,in sq.ft Ar  2045ft Ref. Arch sheet

Design rainfall intensity as specified by the code,in/h i  4.7in ASCE7-10,C8-1,


Arch sheet

3
flow rate out of a single drainage system,in gal/min Q  0.0104 ˜ Ar ˜ i 8.33 ft
i.e.=99.95 gal/min

By interpolation between 6 in and 24 in,for 16 in wide scupper flowrates are as follows,


for 1 in head 48 gal/min and for 2 in head it is 133.33 gal/min

Interpolation between a hydraulic head of 1 and 2 in. as follows,


dh=1+[(99.95-48)/(133.33-48)]=1+0.60 = 1.60 in
The roof and its drainage has been designed so that no more than 4.7" of water is allowed to pond on
any portion of roof. Hence ds+dh =4.7 in

ds = Depth of Water on the un deflected roof up to the d s  3.1in


inlet of secondary drainage system

dh = Depth of Water on the un deflected roof up to the d h  1.6in By interpolation


inlet of secondary drainage system

R. = Rain load on the un deflected roof in lb/ft 2

R  5.2 d s  d h R = 24.44 psf <26 psf


Eqn 8.3-1
ASCE 7-10

Note: 26 psf Rain load was calculated considering the ds+dh=5 in refer to previous pagecalculations.