Sie sind auf Seite 1von 76

Precision Machinery Company

Swash-plate Axial Piston Pump

K3VL Series
CONTENTS

Applications / Product Usage 3

Safety Precautions 4

Handling Precautions 5-8

Conversion Factors, Formula and Definition 9

Specifications and Features


1. Ordering Code
1-1. Pump Options 12 - 14

2. Technical Information
2-1. Specifications 15 - 17

2-2. Technical Data 18

2-3. Performance Data 19 - 25

2-4. Radial Loading Capacity 26

2-5. Functional Description of Regulator 27 - 32

2-6. Torque Limiter Settings 33 - 34

2-7. Installation 35 - 38

3. Dimensions
3-1. K3VL28 Installation 39 - 41

3-2. K3VL45/60 Installation 42 - 46

3-3. K3VL80 Installation 47 - 51

3-4. K3VL112/140 Installation 52 - 59

3-5. K3VL200 Installation 60 - 65

3-6. K3VL200H Installation 66 - 69

3-7. Electric Displacement Control 70

3-8. Unloading & Proportional Pressure Control Installation 71

3-9. Power Shift Control Installation 72

3-10. Calibration of Regulators 73

2
Applications/Product Usage

The following must be taken into consideration before use.

1. The operating condition of the products 4. If the intended use of the products is
shown in this catalog varies depending included in the following, please consult
upon each application. Therefore, the with Kawasaki in advance.
product suitability must be judged by the (1) Use the product in the operating
designer of the hydraulic system and/ conditions or environments other
or the person who finalizes the technical than those described in the technical
specifications of the machine after analysis documents.
and testing. The product specification shall (2) Use the product in the nuclear sector,
be determined based on the latest catalog aviation sector, medical sector, and/or
and technical documents. The system food sector.
must be designed taking into account the (3) Use the product in applications which
possibility of machine failure to ensure may cause substantial harm to others
that all safety, warning, and application and their property, and especially in
requirements are met. applications where ensuring safety is a
requirement.
2. For the proper use of the products,
descriptions given in the SAFETY 5. The information described in this catalog
PRECAUTIONS must be observed. is subject to change without notice. For the
latest information, please contact Kawasaki.
3. The technical information in this catalog
represents typical characteristics and
performance of the products as of the
published date.

3
Safety Precautions

Before using the product, you MUST read this catalog and MUST fully understand how
to use the product. To use the product safely, you MUST carefully read all Warnings and
Cautions in this catalog.

1. Cautions related to operation 3. Warnings and cautions for operation


- Use the personal protective equipment to - Always equip the product with explosion or
prevent injury when the product is in operation. ignition protection if it is used in potentially
explosive or combustible atmospheres.
- Some components are heavy. Handle the
product carefully not to hurt your hands and - Shield rotary parts, such as the motor and
lower back. pump shaft, to avoid injury.

- Do not step on, hit or drop , or apply strong - Stop operation immediately, and take proper
force to the product, as these actions may measures when the abnormality such as
cause operation failure, product damage, or oil unusual noise, oil leakage, and smoke is found.
leakage. Continuing operation under such condition may
bring about damage, a fire hazard, or injury.
- Wipe off any oil on the product or the floor
completely, as oil can create slippery conditions - Make sure that all pipes, hoses, and
that may cause drop of the product and connecting points with pipes or hoses, are
personal injury. correctly connected and tightened before
starting operation.

- Use the product under the operating


2. Warnings and cautions related to conditions and limitations described in the
installation and removal of the product catalog, drawings, and specification sheets.

- Installation, removal, piping, and wiring must - Do not touch the product in operation. to
be done by a qualified technician. reduce the risk of skin burn.

- Make sure that the hydraulic power unit - Use the proper hydraulic oil and maintain the
is turned off and that the electric motor or filtration at the recommended level to prevent
engine has completely stopped before starting premature wear and damage.
installation or removal. You must also check
that the system pressure has dropped to zero.
4. Cautions related to maintenance
- Make sure that the power source is turned off
before installing electric components to reduce - Never modify the product without approval
the risk of electric shock. from Kawasaki.

- Clean the threads and the mounting surface - Disassembly of the product may void the
to prevent damage or oil leakage. Inadequate warranty.
cleaning may cause insufficient torque and
broken seals. - Keep the product clean and dry when storing
or transporting.
- Use the designated bolts and fasten them with
prescribed torque when installing the product. - The seals may need to be replaced if the
Use of undesignated bolts, and excessive or product has been stored for an extended period
insufficient tightening torque may induce of time.
operation failure, damage, or oil leakage.
- Making adjustments of this product will result
in the warranty being null and void.

4
Handling Precuations

1. Operating Fluid and 2. Filtration and Contamination


Temperature Range Control

1) Operating Fluid 1) Filtration of working oil


Values shown in this catalog are based upon using The most important means to prevent premature
mineral oil based anti-wear hydraulic fluid. To damage to the pump and associated equipment
ensure optimal performance use of mineral oil and to extend its working life, is to ensure that
based anti-wear hydraulic fluid is recommended. hydraulic fluid contamination control of the system
is working effectively.
2) Viscosity and temperature range This begins by ensuring that at the time of
installation that all piping, tanks etc. are rigorously
To minimize both oil and seal deterioration, a cleaned in a sanitary way. Flushing should be
maximum operating temperature of 60°C should provided using an off line filtration system
be considered. Please note that the regulator and after flushing the filter elements should be
may become slow to respond when operating replaced.
at low temperatures (below 20°C) in extreme
A full flow return line filter of 10 micron nominal
cold environments. At such low temperature it
should be utilised to prevent contaminant ingress
is strongly suggested that a warm up cycle is
from the external environment, a 5 to 10 micron
introduced until an operating temperature of 20°C
filter with the tank’s breather is also recommended.
is achieved.

2) Suggested acceptable contamination


Normal operating
range
Allowable range level

Viscosity [mm2/s(cSt)] 10 to 200 10 to 1,000 The relationship between contamination level and
pump life is very difficult to predict as it depends
Fluid temperature on the type and nature of the contaminant present
-20 to +95 (-4 to +203)
[°C (°F)] in the system. Sand or Silica in particular, due to
its abrasive nature, does significantly reduce the
expected life of a pump. Based on the precondition
allowable temperature range that there is no significant presence of Silica type
substances then a minimum Cleanliness level of
1000
600 -/18/15 ISO 4406 or SAE AS 4059E Table 1 Class 9
400 (NAS 1638 Class 9).
kinematic viscosity (cSt)

200

100
80
60

40

20

10
−20 0 20 40 60 80 95 100
°C )
Normal operating range

5
3. Drive Shaft Coupling
Alignment between the prime mover and the pump shaft should be within 0.05 mm TIR*. In case the pump is
directly coupled to the engine flywheel, use a flexible coupling.

*TIR = Total Indicator Reading

dial gauge (reading a) dial gauge (reading b)


δ =a/2 0.025mm α=SIN-1 (b/D)
0.2° b

D
δ

α
datums
datums

4. Oil Filling and Air Bleeding


1) Pump case filling
Be sure to fill the pump casing with oil through the drain port, filling only the suction line with oil is totally
in-sufficient. The pump contains bearings and high-speed sliding parts including pistons with shoes and a
spherical bush that need to be continuously lubricated. Part seizure or total premature failure will occur
very quickly if this procedure is not rIgidly followed.

2) Air bleeding
Run the pump unloaded for a period to ensure that all residual air within the system is released.

3) Long term out of usage


It is undesirable to leave the pump out of use for a long period e.g. a year or more. In such a situation it is
recommended that the pump is run for a short period on a more frequent basis even if it is just unloaded.
With regard to a pump held in storage then rotating the shaft on a frequent basis is sufficient. If the pump is
left out for more than the suggested time it will require a service inspection.

6
5. Drain Piping
1) Installation of drain line
It is the preferred option to mount the pump with the case drain piping initially rising above the pump
before continuing to the tank. Do not connect the drain line to the inlet line.

Cautions
Must be higher than
top of pump case.

A) Inlet and drain pipes must be immersed by


200 mm minimum from the lowest level under
operating conditions.

B) Height from the oil level to the centre of the


shaft must be within 1 meter maximum.
minimum depth

C) The oil in the pump case must be refilled when


200mm

the pump has not been operated for one month


Fluid level
or longer.

The uppermost drain port should be used and the drain piping must be larger in size than the drain port
to minimise pressure in the pump case. The pump case pressure must not exceed 1 bar as shown in the
illustration below. (Peak pressure must never exceed 4 bar.)

4 bar
(peak)

P
0.1 sec 1 bar
(normal)

2) Size of drain hose or drain pipe


The internal bore size of the drain hose or drain pipe must be larger than that of the drain port. Arrange the
drain line as short as possible.

6. Shaft Loading and Bearing Life


Although K3VL pumps are equipped with bearings that can accept some external thrust and radial forces,
application of such loads will affect bearing life. Depending on the load magnitude , the load position, and
the load orientation, bearing life may be significantly reduced.

7
7. Mounting the Pump Above the Tank
Suction line.
minimum depth

within 1m
within 1m
200mm

Fluid level

minimum depth
200mm

8. Mounting the Pump Vertically (shaft up)

Note: Both the Tair and one case drain port must be used.

For applications requiring vertical installation (shaft up) please remove the Tair bleed plug and connect piping as
shown in the illustration below.

When installing the pump in the tank and submerged in the oil, open the drain port and Tair bleed port to provide
adequate lubrication to the internal components. See illustration [a].

The oil level in the tank should be higher than the pump-mounting flange as shown in illustration [a] below. If the
oil level in the tank is lower than the pump mounting flange then forced lubrication is required through the Tair
bleed port 1 ~ 2 l/min.

When installing the pump outside the tank run piping for the drain and Tair bleed ports to tank (see illustration
[c]). If the drain or Tair bleed piping rise above the level of oil (see illustration [b]) fill the lines with oil before
operation.motor to your national standard is not exceeded.

Pipe for air


bleeding

Min. Oil level


Oil
Tair Oil Tair
Tair bleeder
plug port
Dr Dr
Drain port Dr Dr

Pipe for
draining
[A]

[B] [C]

8
Conversion Factors, Formula and Definition

Conversion Factors
Formula Note
Displacement 1 cm = 0.061 in
3 3

Pressure 1 MPa - 145 psi


Flow 1 L/min = 0.264 gpm US gallon
Torque 1 Nm = 0.74 lb ft
Power 1 kW = 1.341 hp
Weight 1 kg = 2.205 lb

Formula
Metric system Imperial system
Output flow Q = q x N x η v / 1000 L/min Q = q x N x η v / 231 gal/min
Input torque T = q x ∆P / 2∏ / η m Nm T = q x ∆P / 24∏ / η m lbf ft
Input power L = T x N / 9550 = Q x ∆P / 60 / η t kW L = T x N / 5252 = Q x ∆P / 1714 / η t hp

Definition
q = Pump displacement cm3 (in3)

L = Input power kW (hp)

N = Speed min-1 (rpm)

∆P = Pd - Ps MPa (psi)

Pd = Pump delivery pressure MPa (psi)

Ps = Pump suction pressure MPa (psi)

PL = Load sensing pressure MPa (psi)

Pdr = Pump case pressure MPa (psi)

Pf = Power shift pressure MPa (psi)

Psv = Servo pressure MPa (psi)

T = Input torque Nm (lbf-ft)

Tmax = Maximum input torque Nm (lbf-ft)

ηv = Pump volumetric efficiency

ηm = Pump mechanical efficiency


ηt = Pump total efficiency

9
MEMO

10
K3VL Series
Swash-plate Axial Piston Pump

General Descriptions Features

The K3VL series Swash Plate Type Axial Piston Pumps 320 bar continuous pressure rating
are designed to satisfy the marine, mobile and industrial (250 bar for K3VL60)
markets where a medium/high pressure variable 350 bar peak pressure (280 for K3VL60)
displacement pump is required.
High overall effciency (>90% peak)
K3VL pumps are available in nominal displacements
Exceptional self priming capability
ranging from 28 to 200 cm3/rev with various pressure,
torque limiter, and combination of load sensing control SAE and ISO mounting and shaft
options.
Excellent reliability and very long service
Maximum
Capacity
Rated
self-priming life
Pump Type pressure
(cm3/rev) speed
(bar)
(rpm)
High power to weight ratio
K3VL28 28 320 3,000

K3VL45 45 320 2,700 Numerous control options

K3VL60 60 250 2,400 Highly responsive controls


K3VL80 80 320 2,400
Low pulsation and noise emissions
K3VL112 112 320 2,200

K3VL140 140 320 2,200 Integral unloading or proportional pressure


K3VL200 200 320 1,900 relief valves available
K3VL200H 200 320 2,200
High speed version with integral impeller
(K3VL200H)

11
1 Ordering Code

1-1 Pump Options


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
K3VL 200 / B - 1 N R M M - LN 24D B /1 -H**

1. K3VL Series Pump Preferred product range


AVAILABLE
K3VL Series, Variable Displacement,
Axial Piston, Open Loop Pump NOT AVAILABLE IN
COUNTER CLOCKWISE
PLEASE CONTACT KPM UK
- NOT AVAILABLE

2. Pump Size
Maximum Displacement cm3/rev (H-Impeller) 28 45 60 80 112 140 200 200H

3. Design Series
B Series -
C Series - - - - - - -

4. Hydraulic Fluid Type


- Mineral Oil, Nitrile seal + Viton Shaft Seal
V Viton Seal Throughout
W Water Glycol (Nitrile Seal & Nitrile Shaft Seal) - - -

5. Circuit Type
1 Open Circuit

6. Through Drive & Porting


0 Without Through Drive -
A SAE-A Through Drive, Side Ported
B SAE-B Through Drive, Side Ported
BB SAE-BB Through Drive, Side Ported -
C SAE-C, 2 Bolt, Through Drive, Side Ported - - -
C4 SAE-C, 4 Bolt, Through Drive, Side Ported - - -
CC SAE-CC, 2 Bolt, Through Drive, Side Ported - - - -
D SAE-D Through Drive, Side Ported - - - -
E SAE-E Through Drive, Side Ported - - - - - -
R Single Pump, Rear Ported - - -
N Single Pump with Steel Cover, Side Ported

7. Direction of Rotation
R Clockwise Rotation
L Counter Clockwise Rotation

12
K3VL PUMPS

1-1 Pump Options


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
K3VL 200 / B - 1 N R M M - LN 24D B /1 -H**

8. Mounting Flange & Shaft 28 45 60 80 112 140 200 200H


K SAE Key & Mount -

M ISO Key & Mount - - -

S SAE Spline & Mount


R SAE-C Spline & SAE-D Mount - - - - - -

C SAE-C Spline & SAE-C2 Mount - - - - - -

X SAE-C Key & SAE-C2 Mount - - - - - -

Y SAE-CC Key & SAE-C2 Mount - - - - - -

W SAE-CC Spline & SAE-C2 Mount - - - - - -

F SAE-F Spline & SAE-E Mount - - - - - -

SAE-B Spline & SAE-B, 2 Bolt Mount - - - - - -


T
SAE-CC Spline & SAE-D, 4 Bolt Mount - - - - - -

9. Porting Threads
M Metric Threads
S UNC Thread (Not Available with ‘M’ ISO Key Shaft & Mount)

10. Regulator Type


L0 Load Sense + Pressure Cut-Off (With LS Bleed)
L1 Load Sense + Pressure Cut-Off (With LS Blocked)
LM Load Sense & Intergral Unload (Normally Open) -
LN Load Sense & Intergral Unload (Normally Closed) -
LV Load Sense & Intergral Proportional Relief -
LV2 Load Sense & Intergral Proportional Relief -
P0 Pressure Cut-Off
PM Pressure Cut-Off & Intergral Unload (Normally Open) -
PN Pressure Cut-Off & Intergral Unload (Normally Closed) -
PV Pressure Cut-Off & Intergral Proportional Relief -
PV2 Pressure Cut-Off & Intergral Proportional Relief -
Inverse Proportional Electronic Pressure Control (Only with
PR - - - -
24V DC) (see datasheet P-2002/03.17)

11. Unloader Solenoid


Blank For all other options except PN/PM/LN/LM -
115A 115V AC, 50, 60 Hz - DIN 43550 Plug -
230A 230V AC, 50, 60 Hz - DIN 43550 Plug -
12D 12V DC - DIN 43550 Plug -
24D 24V DC - DIN 43550 Plug (Also for use with PR) -

13
K3VL PUMPS

1-1 Pump Options


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
K3VL 200 / B - 1 N R M M - LN 24D B /1 -H**

12. Additional Control Options 28 45 60 80 112 140 200 200H


Blank -
A With Deutsch Connector (Only for PV2/LV2) -
B With DIN Connector (Only for PV2/LV2) -

13. Additional Control Options


Blank Without Additional Control -
Torque Limiter (with provision for torque limiter or
/1 -
displacement control)
/2 Torque Limiter & Hydraulic Power Shift - - -
/3 Torque Limiter & Power Shift, 24V DC - DIN 43550 Plug - - -

14. Torque Limiting & Displacement Control


Blank Without Additional Control -
-00 Blanking Plate (only for ‘/1’ type) -
-S# Special Low Setting Range (available for ‘/1’ type only) -
-L# Low Setting Range (available for ‘/1’ type only) -
-M# Medium Setting Range (available for ‘/1’ type only) -
-H# High Setting Range (available for all ‘/1’, ‘/2’ & ‘/3’ options) -
Electric Displacement Control (Pilot Pressure Required)
-E0 -
AMP Flying Lead 24V DC
Electric Displacement Control (Pilot Pressure Required)
-E1 -
AMP Moulded 24V DC
Electric Displacement Control (Pilot Pressure Required)
-E2 -
Deutsch Moulded 24V DC
Electric Displacement Control (Pilot Pressure Required)
-E3 -
Deutsch Moulded 12V DC
-Q0 Pilot Operated Displacement Control -

15. Special Suffix


Contact KPM UK

14
K3VL PUMPS

2 Technical Information

2-1 Specifications
Pump Model K3VL28 K3VL45 K3VL60 K3VL80 K3VL112 K3VL140 K3VL200 K3VL200H

Capacity cc/rev 28 45 60 80 112 140 200 200

Rated bar 320 250 320


Pressure
ratings
Peak *1 bar 350 280 350

Self prime *2 rpm 3,000 2,700 2,400 2,400 2,200 2,200 1,900 2,200
Speed
ratings
Max. boosted*3 rpm 3,600 3,250 3,000 3,000 2,700 2,500 2,200 2,200

Minimum operating speed rpm 600


Max.
bar 1
Case drain continuous
pressure
Peak bar 4

Weight kg 20 27 25 35 65 65 95 130

Case fill capacity L 0.6 0.6 0.6 0.8 1.5 1.5 3.0 3.2

Temperature range 0
C -20 to 95

Viscosity range cSt 10 to 1,000 - viscosities greater than 200 will require a no load warm up

Maximum contamination level ISO 4406 18/15


2 - bolt 2 - bolt 4 - bolt 4 - bolt
Mounting
SAE B SAE C SAE D SAE E
Standard SAE mounting
SAE B SAE C SAE D
flange and shaft SAE B-B SAE D
Shaft spline or spline or
spline or key spline or key spline or
key key spline
key
2 - bolt
Mounting - -
Optional SAE mounting SAE C
flange and shaft SAE B SAE B SAE C or C-C SAE F
Shaft - -
spline spline spline or key spline
2 bolt ISO 2 bolt ISO 2 bolt ISO 4 bolt
Mounting - -
Standard ISO mounting 100 100 100 ISO 180
flange and shaft ISO 25mm ISO 25mm ISO 25mm ISO 45mm
Shaft - -
key key key key
Input shaft torque rating refer to table on page 16

SAE A 61 123

SAE B 155 290 340

SAE B-B - 290 550


Through drive torque SAE C - 400 700 990
rating (Nm)
SAE C-C - 700 990

SAE D - 700 990

SAE E *4 - 990

*1 : The instant allowable surge pressure as defined by DIN24312. Life and durability of the pump will be affected.
*2 : Steady state inlet pressure should be greater or equal to 0.9 bar absolute.
*3 : Steady state inlet pressure should be greater or equal to 1.3 bar absolute. The maximum boost pressure should not exceed 10 bar.
*4 : SAE E through drive uses the SAE D shaft.

15
K3VL PUMPS

2-1 Specifications (cont)


Input Shaft Torque Ratings

SAE Splined Shafts

Shaft Designation SAE B SAE B-B SAE C SAE C-C SAE D/E SAE F

Input Torque Rating (Nm) 171 272 552 925 1,470 1,950

SAE Keyed Shafts

Shaft Designation SAE B SAE B-B SAE C SAE C-C SAE D/E

Input Torque Rating (Nm) 145 230 430 700 1,250

ISO Keyed Shafts

Shaft Designation ISO 25mm ISO 32mm ISO 45 mm

Input Torque Rating (Nm) 145 230 430

Note:
The shaft surface will have a finite life due to wear unless adequate lubrication is provided.

#1 Maximum allowable shaft torques are based on achieving an infinite life for a coupling assembly that is
lubricated and completely clamped and utilises the full spline/key length as engagement.

The following points therefore need to be fully considered:-

i) Lubrication of shaft couplings should be in accordance with the coupling manufacturers instructions.

ii) The maximum allowable input shaft torque is based on ensuring an infinite life condition by limiting the
resultant combined shaft bending and torsional stress.

iii) This allowable input shaft torque can be further increased dependant on the resultant surface stress at the
spline interface which is highly dependant on coupling selection and the provision of adequate spline lubrication.

If you have an application that requires higher input torque please consult KPM UK.

#2 Allowable through drive torques are based on the achieving an infinite life for a fully lubricated coupling
and full spline engagement with a mineral oil based anti-wear hydraulic fluid.

16
K3VL PUMPS

2-1 Specifications (cont)


Notes:

Rated Pressure
Pressure at which life and durability will not be affected.

Peak Pressure
The instant allowable surge pressure as defined by BS ISO 2944:2000. Life and durability however will be
shortened.

Maximum Self Priming Speed


Values are valid for an absolute suction pressure of 0.9 bar. If the flow is reduced and the inlet pressure is
increased the speed may also be increased.

Maximum Boosted Speed


Values stated are the absolute maximum permitted speed for which an increased inlet pressure will be required.

Weight
Approximate dry weights, dependant on exact pump type.

Hydraulic Fluid
Mineral anti wear hydraulic fluid - for other fluid types please consult KPM UK.

Viscosity Range
If viscosity is in range 200 to 1,000 cSt, then warming up is necessary before commencing full scale running.

17
K3VL PUMPS

2-2 Technical Data (cont)


Working Fluid Types Pump Start Up Precuations

Anti-Wear Type Hydraulic fluid Piping & Circuit Checking

It is generally recommended to use an anti-wear Check to see that the piping and full hydraulic circuit is
hydraulic fluid like mineral oil when the operating completed and that any gate valves etc. are open.
pressure exceeds 206 bar.
Direction of Rotation
Fire-resistant Fluids Check to ensure that direction of rotation is correct and that

Some kind of fire-resistant fluids require special the inlet and delivery lines are connected correctly.

materials for seals, paint and metal finishing. Please


consult KPM UK and provide details of the particular Start Up
fluid specification and the working conditions so that Jog start the motor and check once more for correct rotation.
any special requirements can be ascertained. Run the pump unloaded for a period to ensure that
all residual air within the system is released. Check for external
In general, fire-resistant fluids have a low viscosity leakage, abnormal noise and vibrations.
index and their viscosity also changes significantly
with operating temperature and service life. For End of Life
this reason, the circuit should be provided with an
adequately sized cooler or forced cooling so that The pump unit, hydraulic fluid and packaging must be disposed

temperatures can be stabilised. Due to the inherent of carefully to avoid pollution to the environment. The pump

water content of some of these fluids the minimum unit must be completely empty upon disposal, it must be

allowable suction pressure will be higher than that disposed of according to national regulations and you must

of an equivalent mineral oil and so needs to be fully also follow safety information for disposal of the hydraulic

evaluated by KPM UK. The following table provides fluid.

an overview of the precautions and characteristics


that can be expected with these types of fluids. All individual parts of the pump unit must be recycled. Separate
the pump unit parts according to: cast parts, steel, aluminium,
non-ferrous metal, electronic waste, plastic, and seals.

Fluid Type Fluid Type


Mineral Mineral
Polyol Polyol
Water Water
Parameter Parameter Oil Oil
Ester Ester
Glycol Glycol

Maximum Maximum
320 320 320
210 210
Pressure (bar)
Pressure (bar)

Recommended
Recommended
Temperature
Temperature 20 ~ 60 20~~60
20 60 20
20~~60
60 20 ~ 60
Range (deg Range
C) (deg C)

Cavitation Cavitation
susceptability
susceptability

Expected life
Expected life
expectancyexpectancy
100% 100%
<100% <100%
20% 20%
compared compared
to mineral oil
to mineral oil

recommended
recommended usable
usable
usable (higher (higher
(higherdensity)
density) density)
18
K3VL PUMPS

2-3 Performance Data


K3VL28

Pump Efficiency (%)


Ratio of displacement
1.0 0.75 0.5 0.25
1 100
Displacement ratio (q/qmax)

0.75 75
87

86

0.5 85 50
84
83
82
81
80
0.25 75 25
70

0 0

0 5 10 15 20 25 30 35
Delivery pressure (bar)

Self Priming Capability

3600

3400 0.2
Inlet pressure (bar)

3200 0.1
Speed (rpm)

3000 0

2800 -0.1

2600
-0.2

2400
14 16 18 20 22 24 26 28
Displacement (cm3/rev)

Performance Note:
All performance curves are based on the following conditions:
• 1,500 rpm
• ISO VG46 mineral oil
• 50ºC oil temperature
• Atmospheric inlet condition (0 bar)

19
K3VL PUMPS

2-3 Performance Data (cont)


K3VL45

Pump Efficiency (%)


Ratio of displacement
1.00 0.75 0.50 0.25
1 100
Displacement ratio (q/qmax)

90
0.75 75

89
88

0.5 86 50
83
80
75
0.25 70 25
60

0 0

0 50 100 150 200 250 300 350


Delivery pressure (bar)

Self Priming Capability


0.2
3200

0.1
3000

Inlet pressure (bar)


0
Speed (rpm)

2800

-0.1
2600

-0.2
2400

2200 0

29 31 33 35 37 39 41 43 45
Displacement (cm3/rev)

Noise Levels

85

80

75
Noise level [dB(A)]

70

65 1800 rpm

60
1500 rpm
55
q = 45 cc/rev
50 Performance Note:
0 50 100 150 200 250 300 350
All performance curves are based on the following conditions:
Delivery pressure Pd [bar]
• 1,500 rpm
• ISO VG46 mineral oil
Noise level measured in an anechoic chamber where distance from
microphone to pump is 1 metre. Measurement accuracy +/- 2 dB(A) • 50ºC oil temperature
• Atmospheric inlet condition (0 bar)

20
K3VL PUMPS

2-3 Performance Data (cont)


K3VL60

Pump Efficiency (%)


Ratio of displacement
1.0 0.75 0.5 0.25
1 100
Displacement ratio (q/qmax)

0.75 75

86

85
0.5 50
84
82
80

0.25 75 25
60 65 70

0 0

0 50 100 150 200 250


Delivery pressure (bar)

Self Priming Capability


3000
0.2

2800
0.1

Inlet pressure (bar)


2600
Speed (rpm)

0
2400

2200 -0.1

2000
-0.2
1800
36 39 42 45 48 51 54 57 60
Displacement (cm3/rev)
Noise Levels
90

85

80
1500 rpm
Noise Level [dB(A)]

75

70
1800 rpm
65

60

55
Performance Note:
50
0 50 100 150 200 250 300 All performance curves are based on the following conditions:
Delivery Pressure [bar] • 1,500 rpm
• ISO VG46 mineral oil
• 50ºC oil temperature
• Atmospheric inlet condition (0 bar)

21
K3VL PUMPS

2-3 Performance Data (cont)


K3VL80

Pump Efficiency (%)


Ratio of displacement
1.0 0.75 0.5 0.25
1 100
Displacement ratio (q/qmax)

92
0.75 75
91

89
0.5 50
87

85
83
80
0.25 25
75
70

0 0

0 50 100 150 200 250 300 350


Delivery pressure (bar)

Self Priming Capability


3000

2800 0.2

Inlet pressure (bar)


0.1
Speed (rpm)

2600

0
2400

-0.1
2200

-0.2
2000
50 55 60 70 80 75 80
Displacement (cm3/rev)

Noise Levels
85

80

75
Noise level [dB(A)]

70

65 1800 rpm

60 1500 rpm

q = 80 cc/rev
55

50
0 50 100 150 200 250 300 350
Performance Note:
Delivery pressure Pd [bar]
All performance curves are based on the following conditions:
Noise level measured in an anechoic chamber where distance from • 1,500 rpm
microphone to pump is 1 metre. Measurement accuracy +/- 2 dB(A) • ISO VG46 mineral oil
• 50ºC oil temperature
• Atmospheric inlet condition (0 bar)

22
K3VL PUMPS

2-3 Performance Data (cont)


K3VL112

Pump Efficiency (%)


Ratio of displacement
1.0 0.75 0.5 0.25
1 100
Displacement ratio (q/qmax)

0.75 92 75

91

0.5 89 50
87
85
83
80
0.25 75 25
70

0 0

0 50 100 150 200 250 300 350


Delivery pressure (bar)

Self Priming Capability


2600 0.2

0.1

Inlet pressure (bar)


2400
Speed (rpm)

2200
-0.1

2000
-0.2

1800
76 82 88 94 100 106 112
Displacement (cm3/rev)

Noise Levels
85

80

75
Noise level [dB(A)]

70
1800 rpm
65
1500 rpm
60

55 q = 112 cc/rev

50
0 50 100 150 200 250 300 350 Performance Note:
Delivery pressure Pd [bar] All performance curves are based on the following conditions:
• 1,500 rpm
Noise level measured in an anechoic chamber where distance from
microphone to pump is 1 metre. Measurement accuracy +/- 2 dB(A) • ISO VG46 mineral oil
• 50ºC oil temperature
• Atmospheric inlet condition (0 bar)

23
K3VL PUMPS

2-3 Performance Data (cont)


K3VL140

Pump Efficiency (%)


Ratio of displacement
1.0 0.75 0.5 0.25
1 100
Displacement ratio (q/qmax)

0.75 75
92

91

0.5 89 50
87
85
83
80
0.25 25
75
70

0 0

0 50 100 150 200 250 300 350


Delivery pressure (bar)

Self Priming Capability


0.1
2400

Inlet pressure (bar)


0
Speed (rpm)

2200

-0.1

2000

-0.2

1800
90 100 110 120 130 140
Displacement (cm3/rev)

Noise Levels
85

80

75
Noise level [dB(A)]

70
1800rpm
65
1500rpm
60
q = 140 cc/rev
55

50
0 50 100 150 200 250 300 350 Performance Note:
Delivery pressure Pd [bar]
All performance curves are based on the following conditions:
• 1,500 rpm

Noise level measured in an anechoic chamber where distance from • ISO VG46 mineral oil
microphone to pump is 1 metre. Measurement accuracy +/- 2 dB(A) • 50ºC oil temperature
• Atmospheric inlet condition (0 bar)

24
K3VL PUMPS

2-3 Performance Data (cont)


K3VL200

Pump Efficiency (%)


Ratio of displacement
1.0 0.75 0.5 0.25
1 100
91
Displacement ratio (q/qmax)

0.75 90
75

89

0.5 87 50
85
83
80
0.25 75 25
70

0 0

0 50 100 150 200 250 300 350


Delivery pressure (bar)

Self Priming Capability


2200
0.2

2100

0.1

Inlet pressure (bar)


2000
Speed (rpm)

1900 0

1800
-0.1

1700

1600 -0.2

120 130 140 150 160 170 180 190 200


Displacement (cm3/rev)
Noise Levels
100

95

90

85
Noise Level [dB(A)]

80 1500 rpm

75

70
1800 rpm
65

60

55

50 Performance Note:
0 50 100 150 200 250 300 All performance curves are based on the following conditions:
Delivery Pressure [bar]
• 1,500 rpm
• ISO VG46 mineral oil
Noise level measured in an anechoic chamber where distance from
microphone to pump is 1 metre. Measurement accurancy +/- 2 dB(A) • 50ºC oil temperature
• Atmospheric inlet condition (0 bar)

25
K3VL PUMPS

2-4 Radial Loading Capacity


No axial shaft loading posible, radial loading is achievable but in specific orientation:-
Radial shaft loading can be allowed provided that its orientation is such that the front bearing takes the additional
load (see diagram below).
Note: In this case bearing life will be reduced.

acceptable

not acceptable

26
K3VL PUMPS

2-5 Functional Description of Regulator


Key to Hydraulic Circuit Annotations
Annotations Description
A Main pump delivery

A1 Auxillary pump delivery

B1 Gear pump inlet

B Main pump inlet

Dr Drain

Pc Remote pilot port, Pressure compensator

Pl Pilot port displacement control

PL Load sense port

Tair Air bleed port

Pf Hydraulic power shift

Psv Servo assist

Regulator Code Control Curves Hydraulic Circuit

PL
L0/L1 Load Sense and
Pressure Cut-off

Pump displacement is controlled to Differential


Pressure Spool
match the flow requirement as a R4
function of the system differential Q
pressure (load pressure vs delivery Cut-off
pressure). In addition, there is a R1
Pressure Spool A
pressure cut off function
incorporated into the control with Tair
the L1 option, the bleed-off orifice P
R4 is plugged.
Dr B

PL

R3

LN Load Sense and Pressure


Cut-off with Integrated Differential
Pressure Spool
Unloading Valve
(Normally Closed) Q
Cut-off
R1 Pressure Spool
An integrated unloading valve is Unloading
sandwiched between the Load Sense Solenoid
Valve
regulator and pump to effectively A
de-stroke and swashplate when an P
electric signal is provided. Tair

Dr B

27
K3VL PUMPS

2-5 Functional Description of Regulator (cont)


Regulator Code Control Curves Hydraulic Circuit
PL

R3

LM Load Sense and Pressure


Cut-off with Integrated
Unloading Valve
(Normally Open)
Q R1
An integrated unloading valve is
A
sandwiched between the Load Sense
regulator and the pump. An electrical
signal must be provided to prevent P Tair
the Load Sense line from draining.

Dr B

PL
LV/LV2 Load Sense and
Pressure Cut-off with
R3
Integrated Proportional
Relief Valve
Differential
Pressure Spool
An integrated proportional relief
valve is sandwiched between the Q
Load Sense regulator and pump Cut-off
to control the maximum pressure R1
Pressure Spool
setting by varying an electric Proportional
Relief
signal to the valve. Valve
A
A separate amplifier is required. P
Tair
Note: LV has improved control
characteristic.
Dr B

L0/1 Load Sense and Pressure PL


Cut-off with Torque Limiting

L0/L1 control functions as


previously noted. In response to
a rise in delivery pressure the Differential
Pressure Spool
swashplate angle is decreased,
Q R4
restricting the input torque. This
regulator prevents excessive load
against the prime mover. Cut-off
Pressure Spool A
The torque limit control module R1
is comprised of two springs that P
oppose the spool force generated by Tair
the system pressure. By turning an
outer and inner spring adjustment
screw, the appropriate input torque Dr B
limit can be set.

28
K3VL PUMPS

2-5 Functional Description of Regulator (cont)


(L0/L1)/2 Hydraulic power shift (L0/L1)/3 Electrical powe
LM Normally open
Regulator Code Control Curves Hydraulic Circuit

Pf a
L
/2-** Hydraulic Power Shift PL
with Load Sensing
P sv
R3
This function, as with the /1
PL PL
type can be used with Pressure
compensation, Load sense and
additional control options such as Power shifted
unloader functions. The control value
has the same function as standard
torque limit option. In response
Q R1
to a rise in delivery pressure R4 R4
the swashplate angle is reduced, A
A R1
restricting input torque. R1
However if a pilot pressure is
applied to the Pf port on the P Tair
regulator, the torque setting can Tair
be further reduced proportionally
to the pilot pressure applied. With L1 option the With L1 option the
The input torque can be reduced Dr B bleed orifice R4 is power shift bleed orifice R4 is
(L0/L1)/2 Hydraulic power shift (L0/L1)/3 Electrical Dr B
LM
by Normally open
approximately 40% . Plugged Plugged

Pf a
P0/2 Hydraulic power shift P0/3 Electrical pow
P/3-**
L Electronic Power Shift
L with Load Sensing
P sv
R3 a
Pf
This function, as with the /1 PL PL
type can be used with Pressure
compensation, Load sense and P sv
additional control options such as Power shifted
Pc Pc
unloader functions. The control value R2
R2
has the same function as standard
R1
torque limit. In response to a rise R4
in delivery pressure the swash-
Q R4
A A
plate angle is reduced, restricting A R1
R1
input torque. However a constant
R4
pressure of 40 bar is required, R4
applied to the Psv port of the Tair Tair
Tair R1
R1 A
regulator. The torque setting can P
be further reduced proportion-
With L1 option the With L1 option the
ally to a 24VDC electrical
Dr signal
B bleed orifice R4 is bleed orifice R4 is
applied to the proportional valve Dr B Tair
Plugged Dr B Plugged
on the regulator.

P0/2 Hydraulic power shift P0/3 Electrical power shift Dr B


Pc

R2
P0 Pressure Cut-off Pf a

As system pressure rises to the


P sv
cutoff setting, the swashplate
Differential
de-strokes to prevent the system Pc
pressure from exceeding the
QPc R2
Pressure Spool
R2
compensator setting. It is
imperative that a safety relief
valve be installed in the system. Cut-off
Pressure Spool A
R1
Note: By connecting the Pc port to P R4
a remote pressure control, R4
Tair
variable pump pressure control R1 A
R1 A
can be achieved.
Dr B
Tair
Tair
29

Dr B
D B
K3VL PUMPS

2-5 Functional Description of Regulator (cont)


Regulator Code Control Curves Hydraulic Circuit

Pc

R2

PN Pressure Cut-off with


Integrated Unloading Valve Differential
(Normally Closed) Q Pressure Spool

An integrated unloading valve is Cut-off


sandwiched between the R1 Pressure Spool
Pressure Cut-off regulator and Solenoid
Valve
pump to effectively de-stroke the P
A
swashplate when an electric signal
is provided.
Tair

Dr B

Pc

R2

PM Pressure Cut-off with Differential


Pressure Spool
Integrated Unloading Valve Q
(Normally Open)
Cut-off
An integrated unloading valve is R1 Pressure Spool
Solenoid
sandwiched between the Pressure Valve
Cut-off regulator and the pump. P A
An electrical signal must be provided
to prevent the Pc line from draining.
Tair

Dr B

Pc

R2
PV/PV2 Pressure Cut-off
with Integrated Proportional
Relief Valve Differential
Pressure Spool
An integrated proportional relief Q
valve is sandwiched between the
Pressure Cut-off regulator and Cut-off
R1 Pressure Spool
the pump to control the maximum
pressure setting by varying an Proportional
Relief
electric signal to the valve. Valve
A separate amplifier is required. P A

Note: PV has improved control Tair


characteristic

Dr B

30
K3VL PUMPS

2-5 Functional Description of Regulator (cont)


Regulator Code Control Curves Hydraulic Circuit

Torque Spool
Limiter
P0/1 Pressure Cut-off
with Torque Limiting PC
Outer Spring R2
P0/1 control functions as Adjustment
previously noted. In response Q
to a rise in delivery pressure Outer Plus Inner
Pump Flow

the swashplate angle is reduced, Spring Adjustment Differential


Pressure Spool
restricting the input torque. This
regulator prevents excessive load
against the prime mover. Cut-off
Pressure Spool
R1 A
Note: By connecting the Pc port to
a remote pressure control, variable P Tair
pump pressure control can
be achieved. Delivery Pressure
Dr B

/1-E0 Electrical
Displacement Control Qmax
Pump Flow Rate (Q)

Pi
Varying the input current signal
to the pump controller’s electronic
Pc
proportional pressure reducing valve
(PPRV) allows the user to control the
pump displacement. As the current
signal to the PPRV increases, the
pump displacement increases Qmin A
proportionally. 360 600 Tair A1

Note: An external pressure supply of Input Current (mA) of Proportional


40 bar is required at the Pi Port Pressure Reading Valve B1
Dr B
(50 bar max). Customer
Supplied

/1-Q0 Pilot Operated


Qmax
Displacement Control Pi
Pump Flow Rate (Q)

Varying the input pressure signal to Pc


the Pi port allows the user to control
the pump displacement. As the
pressure signal to the Pi increases,
the pump displacement
increases proportionally. A
Qmin
Note: An external pressure supply of A1
0 9 28 Tair

up to 40 bar is required at the Pi


Port (50 bar max). Pilot Pressure (bar)
B1
Dr B
Customer
Supplied

31
PL PL

K3VL PUMPS
R1
R4 R4
A
A R1
R1

Tair
Tair

With L1 option the With L1 option the


(L0/L1)/2 Hydraulic power shift Dr B (L0/L1)/3 Electrical power shift
2-5 Functional Description of Regulator (cont)
LM Normally open bleed orifice R4 is
Plugged Dr B
bleed orifice R4 is
Plugged

Pf a
PL P0/2 Hydraulic power shift P0/3 Electric
Regulator Code L Control Curves Hydraulic Circuit
P sv
R3
PL Pf a
PL
/2-** Hydraulic Power Shift
with Pressure Compensation P sv

This function, as with the /1 type can Pc Pc


R2
be used withR1 Pressure compensation, R2
Load sense and additional control Power shifted R4
R4
options such as unloader functions.
A value
R1 A
The control has the same function R1 A
as standard torque limit option. In Q
response to a rise in delivery pres- T R4
air R4 Tair
sure the swashplate angle is reduced, Tair
restricting input torque. However if A R1
R1
a pilot pressure is applied to the Pi With L1 option the With L1 option the
port on the regulator, the torque
Dr B set- bleed orifice R4 is bleed orifice R4 is Dr B
ting can be further reduced propor- Plugged P Dr B Plugged Tair
tionally to the pilot pressure applied.
The input torque can be reduced by
approximately 40% . P0/2 Hydraulic power shift P0/3 Electrical power shift
L Dr B

Pf a
/3-** Electronic Power Shift
with Pressure Compensation
P sv
This function, as with the /1 type can Pc Pc
be used with Pressure compensation, R2
R2
Load sense and additional control Power shifted
options such as unloader functions. value
The control has the same function as
standard torque limit. In response to Q
a rise in delivery pressure the swash- R4
plate angle is reduced, restricting R4
input torque. However a pilot pres- R1 A
R1 A
sure of 40 bar is required, applied
to the Pi port of the regulator. The
torque setting can be further reduced P Tair
Tair
proportionally to a 24VDC electrical
signal applied to the proportional
valve on the regulator.
Dr B
Dr B

32
K3VL PUMPS

2-6 Torque Limiter Settings


The following tables show the power limitation at various electric motor speeds for a specific frame size
of pump. When selecting a control setting please ensure that the power limitation of a particularly sized electric
motor to your national standard is not exceeded.

K3VL45 K3VL60 K3VL80


KW 970 1150 1450 1750 KW 970 1150 1450 1750 KW 970 1150 1450 1750
3.7 S3 S4 - - 3.7 - - - - 3.7 - - - -
5.5 L3 S1 S3 S4 5.5 S2 S2 - - 5.5 S2 S4 - -
7.5 L1 L2 L4 S2 7.5 L4 S1 S3 - 7.5 L6 S1 S3 -
11 M1 M3 L1 L2 11 M4 L2 S1 S2 11 L2 L4 L6 S1
15 H3 H4 M2 M4 15 M2 M3 L2 L3 15 M4 L1 L3 L5
18.5 - H2 H4 M2 18.5 H2 M1 M3 L1 18.5 M1 M3 L1 L3
22 - - H3 H4 22 - H2 M2 M3 22 H3 M1 M4 L1
30 - - - H1 30 - - H2 H3 30 H1 H2 H4 M2
37 - - - - 37 - - - H1 37 - - H2 H4
45 - - - - 45 - - - - 45 - - H1 H2
55 - - - - 55 - - - - 55 - - - H1
75 - - - - 75 - - - - 75 - - - -
90 - - - - 90 - - - - 90 - - - -
110 - - - - 110 - - - - 110 - - - -
132 - - - - 132 - - - - 132 - - - -

K3VL112 K3VL140 K3VL200


KW 970 1150 1450 1750 KW 970 1150 1450 1750 KW 970 1150 1450 1750
3.7 - - - - 3.7 - - - - 3.7 - - - -
5.5 - - - - 5.5 - - - - 5.5 - - - -
7.5 S5 S6 - - 7.5 - - - - 7.5 - - - -
11 S1 S3 S5 S6 11 S2 S4 - - 11 - - - -
15 L3 L4 S2 S4 15 L6 S1 S3 - 15 - - - -
18.5 M4 L2 L4 S2 18.5 L3 L5 S1 S3 18.5 S1 - - -
22 M2 M4 L3 L4 22 L1 L3 L6 S1 22 L4 S1 - -
30 H4 M1 M3 L1 30 M2 M3 L2 L4 30 L2 L3 L5 S2
37 H2 H3 M1 M3 37 H4 M1 M3 L2 37 M3 L1 L3 L5
45 - H2 H4 M1 45 H2 H4 M2 M3 45 M1 M3 L2 L3
55 - - H2 H4 55 - H2 H4 M2 55 H5 M1 M3 L2
75 - - - H1 75 - - H1 H3 75 H1 H3 H6 M2
90 - - - - 90 - - - H1 90 - H1 H4 H6
110 - - - - 110 - - - - 110 - - H2 H4
132 - - - - 132 - - - - 132 - - - H2

33
K3VL PUMPS

2-6 Torque Limiter Settings (cont)


Torque Limiter Control - Setting Table
K3VL Prime Mover Input Torque (Nm)
frame
size 30 36 41 46 49 53 61 73 82 91 100 107 121 146 154 163 182 200 216 246 298 307 367 409 450 492 540 610 618 711 752

45 S4 S3 S2 S1 L4 L3 L2 L1 M4 M3 M2 M1 H4 H3 H2 H1 - - - - - - - - - - - - - - -

60 - - - S4 S3 S2 S1 L4 L3 L2 L1 M4 M3 M2 H3 H2 H1 - - - - - - - - - - - - - -

80 - - - S4 S3 S2 S1 L6 L5 L4 L3 L2 L1 M4 M3 M2 M1 H4 H3 H2 H1 - - - - - - - - - -

112 - - - - - - S6 S5 S4 S3 S2 S1 L4 L3 L2 L1 M4 M3 M2 M1 H4 H3 H2 H1 - - - - - - -

140 - - - - - - - - - S4 S3 S2 S1 L6 L5 L4 L3 L2 L1 M3 M2 M1 H4 H3 H2 H1 - - - - -

200
- - - - - - - - - - - - - - - S2 S1 L5 L4 L3 L2 L1 M3 M2 M1 H6 H5 H4 H3 H2 H1
& 200H

Note: Highlighted options show power shift

Power Shift Control - Setting Table

/2 Hydraulic K3VL80 K3VL112 K3VL140 K3VL200(H)


Spring Setting H4 H3 H2 H1 H4 H3 H2 H1 H4 H3 H2 H1 H6 H5 H4 H3 H2 H1

0 200 216 246 298 298 307 367 409 367 409 450 492 492 540 610 618 711 752

Pf 10 167 183 209 252 252 255 309 349 309 349 383 421 421 453 517 524 610 648
Pressure
(bar) 20 138 152 175 210 210 208 256 292 256 292 322 356 356 374 432 439 517 553

30 111 123 145 173 173 167 209 241 209 241 266 298 298 303 355 361 433 465

/3 Electric K3VL80 K3VL112 K3VL140 K3VL200(H)


Spring Setting H4 H3 H2 H1 H4 H3 H2 H1 H4 H3 H2 H1 H6 H5 H4 H3 H2 H1

0 200 216 246 298 298 307 367 409 367 409 450 492 492 540 610 618 711 752

336 167 183 209 252 252 255 309 349 309 349 383 421 421 453 517 524 610 648
Current
(mA)
473 138 152 175 210 210 208 256 292 256 292 322 356 356 374 432 439 517 553

595 111 123 145 173 173 167 209 241 209 241 266 298 298 303 355 361 433 465

34
K3VL PUMPS

2-7 Installation
Moment of Inertia and Torsional Stiffness
Moment of Inertia Torsional Stiffness
Frame Size
I (kg.m2) GD (kgf.m )
2 2 (N m/rad)

K3VL28 2.09x10-3 8.36-10-3 2.20 x 104

K3VL45 3.85x10-3 1.54-10-2 3.59 x 104

K3VL60 3.83x10-3 1.53-10-2 3.59 x 104

K3VL80 7.30x10-3 2.92-10-2 4.83 x 104

K3VL112 2.02x10-2 8.06-10-2 9.33 x 104

K3VL140 2.02x10-2 8.06-10-2 9.33 x 104

K3VL200 4.58x10-2 1.83-10-1 1.54 x 105

K3VL200H 4.58x10-2 1.83-10-1 1.54 x 105

Through Drive Limitations


Pump over all length (LPX) (mm) Maximum Permisable
Frame size
Frame size Single pump type N Bending Moment

K3VL28 219 K3VL28 137

K3VL45 244 K3VL45 137

K3VL60 244 K3VL60 137

K3VL80 272 K3VL80 244

K3VL112 307 K3VL112 462

K3VL140 307 K3VL140 462

K3VL200 359 K3VL200 930

K3VL200H 424 K3VL200H 930

35
K3VL PUMPS

2-7 Installation (cont)


Through Drive Limitations (cont)
Pump approx weight (MPX)(Kg) Adaptor Kits Weights (MAX) & Width (LAX)
Single pump type N Frame Weight Width
Frame size Adaptor Kit
Size (MAX) Kg (LAX) mm
Without With
Torque Limitor Torque Limitor SAE ‘A’ 0 0
K3VL28
K3VL28 22 na SAE ‘B’ 2 20
K3VL45 28 30
SAE ‘A’ 0 0
K3VL45
K3VL60 28 30
& 60
SAE ‘B’ & ‘BB’ 2 20
K3VL80 38 40
SAE ‘A’ 0 0
K3VL112 69 71

K3VL140 69 71 K3VL80 SAE ‘B’ & ‘BB’ 3 20

K3VL200 103 105


SAE ‘C’, ‘CC’ & ‘C4’ 4 24.5
K3VL200H 142 140
SAE ‘A’ 0 0
Pump CofG from mount (Lx) (mm)
Frame size SAE ‘B’ & ‘BB’ 3 25
K3VL112
Single pump type N & 140
SAE ‘C’, ‘CC’ & ‘C4’ 5 30
K3VL28 115

K3VL45 120 SAE ‘D’ 10 43

K3VL60 120 SAE ‘A’ 1 6

K3VL80 130 SAE ‘B’ & ‘BB’ 8 25


K3VL112 150 SAE ‘C’, ‘CC’ & ‘C4’ 8 30
K3VL200
K3VL140 150
SAE ‘D’ 10 38
K3VL200 190
SAE ‘E’ 15 38
K3VL200H 223

Apart from predefined maximum throughput limitations, one must also ensure that to prevent a possible excessive
bending moment occurring that the maximum combined bending moment of the combination is not exceeded as
determined in the following expression.

LP2
LP1 LA1 LA2
L2
MPX = mass of pump [kg]
LPX = length of pump [mm]
MP1 MP2 MP3
Lx = distance of CofG from pump mounting face [mm]
MA1 MA2
MAX = mass of adaptor kit [kg]
L1 L2 L3
LA1’ LAX = width of adaptor kit [mm]
LP2’
LA2’
LP3’

Bending Moment = ((L1.mP1) + (LA1’.mA1) + (LP2’.mP2) +(LA2’.mA2) +LP3’.mP3) +…)/102[Nm]


((L1.mP1)
+ (LP1+(LA1/2)).mA1
+ (LP1+LA1+L2).mP2
+ (LP1+LA1+LP2(LA2/2)).mA2)
+ (LP1+LA1+LP2+LA2).mP3) 36
+……)/102
K3VL PUMPS

2-7 Installation (cont)


Response times
Pressure Cut-off Dynamic Response
toff-stroke ton-stroke
50 to 280 bar

t t

Tilting Angle (%)


off-stroke on-stroke 100%
Unit mS 50%
K3VL28 20 40 350 (5075) 0%

ssure - bar (psi)


300 (4350)
K3VL45/60 60 100
250 3
( 625)
K3VL80 95 170
200 (2900)
K3VL112/140 90 140
Delivery Pre

150 (2175)
K3VL200/H 110 210 100 (1450)
Test conditions: 50 (725)
Pump speed = 1800 rpm 0
Inlet Condition = 0 bar Time (mS)
Oil Type = ISO VG46
Oil Temperature = 50°C
Compressed oil volume = 5 litres

220 to 280 bar toff-stroke ton-stroke

t off-stroke t on-stroke

Tilting Angle (%)


100%
Unit mS
50%
K3VL28 20 40 350 (5075) 0%
K3VL45/60 60 70
ssure - bar (psi)

300 (4350)
250 3
( 625)
K3VL80 100 110
200 (2900)
K3VL112/140 100 120
Delivery Pre

150 (2175)
K3VL200/H 110 220 100 (1450)
Test conditions: 50 (725)
Pump speed = 1800 rpm
0
Inlet Condition = 0 bar
Time (mS)
Oil Type = ISO VG46
Oil Temperature = 50°C
Compressed oil volume = 5 litres

Load Sensing Dynamic Response


20 to 280 bar ton-stroke toff-stroke
t off-stroke t on-stroke
Tilting Angle (%)

100%
Unit mS
50%
K3VL28 20 70 0%
350 (5075)
K3VL45/60 20 115
ssure - bar (psi)

300 (4350)

K3VL80 55 155 250 3


( 625)
200 (2900)
K3VL112/140 55 195
Delivery Pre

150 (2175)
K3VL200/H 65 190 100 (1450)
Test conditions:
50 (725)
Pump speed = 1800 rpm
Inlet Condition = 0 bar 0
Time (mS)
Oil Type = ISO VG46
Oil Temperature = 50°C
Compressed oil volume = 5 litres

Note:
The response values shown in the table above are typical of those experienced in the laboratory.
Actual reposnse time will vary with different hydraulic circuits.
37
K3VL PUMPS

2-7 Installation (cont)


Electrical and Pilot Operated Displacement Control (Type E0, E1, E2, E3 & Q0)

Type E0 - In order for the electronic displacement control to function, a pilot pressure of 40 bar must be
supplied to the Pi port on the regulator. A gear pump attached to the rear of the K3VL pump or an external
pressure source can be used to provide the required pilot pressure.

Type Q0 - In order for the Q0 displacement control to function, a variable pilot pressure between 0 and 40 bar
is requiredto be supplied to the Pi port on the regulator.

Proportional Pressure Reducing Valve Specification

Maximum Pilot Pressure : 50 bar (if higher pressure


required contact KPM UK)
Max Flow: : 10 l/min
Hydraulic oil : Mineral oil
Oil temp range : -20~+900C
Viscosity range : 5~500 cSt

Electrical Specifications
E0, E1, E2 E3
24V DC 12V DC

Rated Current 700 mA 1,400 mA

Recommended
80 Hz/200 mAp-p 80 Hz/200 mAp-p
Dither

Coil
17.5 Ω 3.2 Ω
Resistance

Ambient
Temperature -30 ~+95ºC -30 ~+95ºC
Range

Water According to JIS D 0203 S2 According to JIS D 0203 S2


Resistance SAE J575 SAE J575

IP Rating IPX6 IPX6

38
K3VL PUMPS

3 Dimensions

3-1 K3VL28 Installation


K3VL28 with Cut-Off / Load Sense Control (Clockwise Rotation)

Inlet and outlet ports reversed for counter clockwise roation.


PL PL

SAE B 2 hole
SAE J744-101-2
Dr PL
A

9
Dr
PL

-0.0
B
K3VL28

0
A

Ø
Dr

9
a1
0
Dr
9 7 -0.
B

PL PL
PL PL

2-Ø
7

Dr
Dr

7
7

B
A C1
0.98

Dr
Ø 9 Dr
9
9

See Port Details


See Port Details
a1 Tair Tair

77
77

97

Port Details

Tightening
Des. Port Name Port Size and Description
Torque (Nm)

¾ SAE J518C Code 61 (5,000 psi)


A Delivery Port 57
Unified Thread Type ‘S’ ⅜-16-2B(0.66”)
1¼ SAE J518 Code 61 (3,000 psi)
B Inlet Port 57
Unified Thread Type ‘S’ 7⁄16 -16-2B(0.66”)

Dr Drain Port ½ O-Ring Boss -8 SAE J1926/1 (¾”-16 UNF-2B) 98

P P0/L0 Control Port ¼ O-Ring Boss -4 SAE J1926/1 (7⁄16”-20 UNF-2B) 12

T Air Bleed Port ¼ O-Ring Boss -4 SAE J1926/1 (7⁄16”-20 UNF-2B) 12

a Gauge Port ¼ O-Ring Boss -4 SAE J1926/1 (7⁄16”-20 UNF-2B) 12

39
K3VL PUMPS

3-1 K3VL28 Installation (cont)


K3VL28 Shaft & Through Drive Options

Model Code Option ‘K’ Shaft Model Code Option ‘S’ Shaft

41
41
6.35

33 33
28
22.22

21.8
24.

28

M8-1.5 SAE B 30° Involute Spline Shaft


SAE B Straight Key
SAE J744-22-1
1
25

Through Drive SAE ‘A’

SAE A 2 hole
SAE J744-82-2

SAE A 30° Involute Spline


45°
+0.035
Ø82.55

4 - M10
Depth 1

8 106
2
204

Through Drive SAE ‘B’

SAE B 2 hole
SAE J744-101-2

SAE B 30° Involute Spline


45°
+0.035
Ø101.6

4 - M12
Depth 20

8
138

48
224

40
K3VL PUMPS

3-1 K3VL28 Installation (cont)


K3VL28 Adaptor Kits

402 317

742
263 116
116

743

743 743
415

Cover Kit SAE ‘A’ T/D Kit SAE “B” T/D KIT

SAE ‘A’ SAE ‘B’


Part Name Qty Cover Kit
T/D Kit T/D Kit

T/D - 29L8TN 29L3TA 29L3TB

O-Ring 1 Item 743 Item 743 Item 743

O-Ring 1 - - Item 742

Screw Hex SHC 4 - - Item 415

Screw Hex SHC 2 Item 402 - -

Subplate 1 - - Item 317

Cover 1 Item 263 - -

Coupling 1 - Item 116 Item 116

41
K3VL PUMPS

3-2 K3VL45/60 Installation


K3VL45/60 with Cut-Off / Load Sense Control & Torque Limit Module
(Clockwise Rotation)

119
See Torque Limit Detail 6.5
and Adjustment
Pl/Pc 154
A
55

Pl/Pc

70
Dr
166
89

80
99
B
A
73

80
Dr
160 B

70
See Max. Flow Adjustment Detail
Adjustment screw Adjustment screw for
for cut-off pressure Adjustment screw for
differential pressure
horsepower setting
Pl/Pc PL/Pc
Pl/Pc
14
.3
40

ø38
144

ø25 Dr
45
°
52.4 ±0.2

Tair 69.8 ±0.2


40

Dr
A Tair B
ø90

See Port Dr
45

Details Dr
See Port
°

Details
26.2 ±0.2 91 13
14
.3

184 91 35.7 ±0.2


184
218

Note: for counter clockwise rotation, the inlet port ‘B’ and the delivery port ‘A’ are reversed.

42
K3VL PUMPS

3-2 K3VL45/60 Installation (cont)


K3VL45/60 Mounting Flange and Shaft Options

SAE Type ISO Type


Flange
SAE "B" 2 hole ISO 3019/2-100A2HW
SAE J744-101-2
ø101.6h7 -0.035

-0.054
0

0
ø100h8
9.7 9.7 +0.5
0
40
46

46 52
ø1
ø1

SAE ‘BB’ Spline Shaft - Option 'S' SAE ‘BB’ Straight Shaft - Option 'K'
38
+0.03

38
ø25.4 -0.05

6.3 0

33 32
28.1 ±0.13
0
ø24.981

M8

SAE "BB" 30° Involute Spline Shaft SAE "BB" Straight Shaft
SAE J744-25-4 15T 16/32 DP SAE J744-25-1
19
25

SAE ‘B’ Spline Shaft - Option 'T' ISO Straight Shaft - Option 'M'
ø8 -0.036

42
0
ø28 -0.3

+0.009
-0.004

36
0

ø25j6
Ø21.806

M8

28 Shaft end
SAE “B” 30o Involute Spline Shaft
33 ISO 3019/2-G25N
SAE J744-22-4 13T 16/32 DP 19
25

43
K3VL PUMPS

3-2 K3VL45/60 Installation (cont)


K3VL45/60 Rear Port
119

PL/PC 24
pump rotating direction 8 PL/PC

(UNC screw)
In case of

9.2
S

144
K3VL45/B-1RR S
K

26.2±0.3
ø38
89

Tair
B ø25
Dr

69.8±0.3
4-⅜ -16UNC-2B
73

depth 18
73 In case of
S
K3VL45/B-1RR S
K
226 depth 22
4-M10
In case of
S
depth 17
K3VL45/B-1RR S
K 35.7±0.3 52.4±0.3 In case of
S
58 44 K3VL45/B-1RR M
4-M12 K
depth 20 90 80
In case of
S
K3VL45/B-1RR M
K

K3VL45/60 Porting Details


Main SAE Flanged Ports
Tightening Flange
Des. Port Name Port Size
Torque (Nm) Threads

UNF Threaded Version (‘S’ in position 9 of model code)


A Delivery Port SAE J518C Std pressure (code 61) 1” 57 ⅜-16UNC-2B x 18 mm

B Suction Port SAE J518C Std pressure (code 61) 1.5” 98 ½-13UNC-2B x 22 mm

Metric Version (‘M’ in position 9 of model code)


A Delivery Port SAE J518C Std pressure (code 61) 1” 57 M10 x 17

B Suction Port SAE J518C Std pressure (code 61) 1.5” 98 M12 x 20

Auxillary Ports
Tightening
Des. Port Name Port Size
Torque (Nm)

SAE Version (‘S’, ‘K’, or ‘T’ in position 8 of model)


SAE J1926/1 Straight thread O ring boss
Dr Drain Port (x2) 98
½” OD Tube ¾-16UNF-2B
Load Sensing Port SAE J1926/1 Straight thread O ring boss
PL /PC 12
Pressure Control Port ¼” OD Tube 7⁄16 -20UNF-2B
SAE J1926/1 Straight thread O ring boss
Tair Air Bleeder Port 12
¼” OD Tube 7⁄16 -20UNF-2B
ISO Version (‘M’ in position 8 of model code)
Dr Drain Port (x2) M22 x 1.5 DIN 3852 98

Load Sensing Port


PL /PC M14 x 1.5 DIN 3852 25
Pressure Control Port

Tair Air Bleeder Port M14 x 1.5 DIN 3852 25


44
K3VL PUMPS

3-2 K3VL45/60 Installation (cont)


K3VL45/60 Through Drive Options

Through Drive ‘A’


SAE "A" 2 hole

+0.050
+0.020
SAE J744-82-2

°
45
Tair

ø82.55
B

ø1
06
Dr

8 6 - M10
30 Depth 17
244
SAE "A" 30° Involute Spline
SAE J744-16-4 9T 16/32 DP

Through Drive ‘B’ Pl/Pc


SAE "B" 2 hole
SAE J744-101-2
+0.035
0

°
45
ø101.6

Tair
B

Dr ø1
46

11 4 - M12
47 Depth 20
264
SAE "B" 30° Involute Spline
SAE J744-22-2 13T 16/32 DP

Through Drive ‘BB’ Pl/Pc


SAE "BB" 2 hole
SAE J744-101-2
+0.035
0

°
45
ø101.6

Tair
B

Dr ø1
46

11 4 - M12
47 Depth 20
264
SAE "BB" 30°Involute Spline
SAE J744-25-2 15T 16/32 DP

45
K3VL PUMPS

3-2 K3VL45/60 Installation (cont)


K3VL45/60 Adaptor Kits
402
317

116 116
314

743 743 743

742
415

COVER KIT SAE ‘A’ T/D KIT SAE ‘B’ & ‘BB’ T/D KIT

SAE ‘A’ SAE ‘B’ SAE ‘BB’


Part Name Qty Cover Kit
T/D Kit T/D Kit T/D Kit

T/D - 29L8TN 29L4TA 29L4TB 29L4T2

O-Ring 1 Item 743 Item 743 Item 743 Item 743

O-Ring 1 - - Item 742 Item 742

Screw Hex SHC 4 - - Item 415 Item 415

Screw Hex SHC 2 Item 402 - - -

Subplate 1 - - Item 317 Item 317

Cover 1 Item 314 - -

Coupling 1 - Item 116 Item 116 Item 116

46
K3VL PUMPS

3-3 K3VL80 Installation


K3VL80 with Cut-Off / Load Sense Control & Torque Limit Module
(Clockwise Rotation)

See Torque Limit Detail 119


and Adjustment 14

PL/PC 164
62

79
A
182

Dr
PLPC
98

85
99
B
A

85
91

Dr B

79
181

See Max. Flow Adjustment Detail

Adjustment screw for


Adjustment screw Adjustment screw for
horsepower setting
for cut-off pressure differential pressure

PL/PC
PL/PC PL/PC
17
.5

L
155

ø50
ø25
45

Dr
°

35

Tair
77.8 ±0.3
52.4 ±0.2

A Dr Tair B
ø114
35

Dr
45

Dr
°

See Port
See Port
Details 26.2 ±0.2 95 18
17

Details
.5

217 95 42.9 ±0.3


217
260

Note: for counter clockwise rotation, the suction port ‘B’ and the delivery port ‘A’ are reversed.

47
K3VL PUMPS

3-3 K3VL80 Installation (cont)


K3VL80 Mounting Flange and Shaft Options

SAE Type ISO Type


SAE "C" 2 hole Flange
SAE J744-127-2 ISO 3019/2-125A2HW

-0.063
ø127 -0.05

0
0

ø125h8
0
12.7 -0.5 9 +0.5
0
81

80
ø1

ø1

56 68

SAE ‘C’ Spline Shaft - Option 'S' SAE ‘C’ Straight Shaft - Option 'K'
48
-0.025

48
+0.002

+0.002

44
0

43
ø31.75h7
0

0
ø35.2

7.94
ø31.224

M8

SAE "C" Straight Shaft


SAE "C" 30° Involute Spline Shaft SAE J744-32-1
19
SAE J744-32-4 14T 12/24 DP
25

ISO Straight Shaft - Option 'M'


58
10h9 -0.036
+0.018
-0.002
0

4 50
ø35 -0.3
0

ø32k6

M12

Shaft end – ISO 3019/2-G32N

28
38

48
K3VL PUMPS

3-3 K3VL80 Installation (cont)


K3VL80 Rear Port Adapter tightening torque: 12Nm
(Not attached but supply with pump)
119
24
8
PL/P C PL/PC

for pump rotating


direction

(UNC screw)

182

178
155
ø50
ø25
98

77.8 ±0.3
26.2 ±0.3 A B

Tair
Dr
79

91

Dr

Depth 22
239
52.4 ±0.3 42.9 ±0.3

Depth 18 54 56.5
90 95

K3VL80 Porting Details


Main SAE Flanged Ports
Tightening Flange
Des. Port Name Port Size
Torque (Nm) Threads

UNF Threaded Version (‘S’ in position 9 of model code)


A Delivery Port SAE J518C Std pressure (code 61) 1” 57 ⅜-16UNC-2B x 18 mm

B Suction Port SAE J518C Std pressure (code 61) 2” 98 ½-13UNC-2B x 22 mm

Metric Version (‘M’ in position 9 of model code)


A Delivery Port SAE J518C Std pressure (code 61) 1” 57 M10 x 17

B Suction Port SAE J518C Std pressure (code 61) 2” 98 M12 x 20

Auxillary Ports
Tightening
Des. Port Name Port Size
Torque (Nm)

SAE Version (‘S’, ‘K’, or ‘T’ in position 8 of model)


SAE J1926/1 Straight thread O ring boss
Dr Drain Port (x2) 98
½” OD Tube ¾-16UNF-2B
Load Sensing Port SAE J1926/1 Straight thread O ring boss
PL /PC 12
Pressure Control Port ¼” OD Tube 7⁄16 -20UNF-2B
SAE J1926/1 Straight thread O ring boss
Tair Air Bleeder Port 12
¼” OD Tube 7⁄16 -20UNF-2B
ISO Version (‘M’ in position 8 of model code)
Dr Drain Port (x2) M22 x 1.5 DIN 3852 98

Load Sensing Port


PL /PC M14 x 1.5 DIN 3852 25
Pressure Control Port

Tair Air Bleeder Port M14 x 1.5 DIN 3852 25


49
K3VL PUMPS

3-3 K3VL80 Installation (cont)


K3VL80 Through Drive Options
Through Drive ‘A’
SAE "A" 2 hole
SAE J744-82-2

+0.035
0
°
45
Tair
ø82.55
B

ø1
06
Dr

8 6 - M10
Through Drive ‘B’
Depth 17
272 33

SAE "A" 30° Involute Spline SAE "B" 2 hole


SAE J744-101-2
SAE J744-16-4 9T 16/32 DP

+0.035
0
°
45
Tair

ø101.6
ø1
46
Dr

Through Drive ‘BB’ 11 4 - M12


Depth 20
47
292
SAE "BB" 2 hole
SAE J744-101-2 SAE "B" 30° Involute Spline
+0.035

SAE J744-22-2 13T 16/32 DP


0
°
45

Tair
ø101.6

ø1
Dr 46
Through Drive ‘C’
11 4 - M12
47 Depth 20
292 SAE "C" 2 hole
SAE J744-127-2
+0.035

SAE "BB" 30°Involute Spline


SAE J744-25-2 15T 16/32 DP
0

°
45

Tair
ø127

ø1
Dr 81

Through Drive ‘C4’ 14


53
4 - M16
Depth 24.5
296.5
PLPC SAE "C" 2 hole
SAE J744-127-2
SAE "C" 30°Involute Spline
+0.035

25° 25° SAE J744-33-4 14T 12/24 DP


0

Tair
ø127

Dr

14 4 - M12
4 - M12 Through
53
301.5

SAE "C" 30°Involute Spline


SAE J744-33-4 14T 12/24 DP

50
K3VL PUMPS

3-3 K3VL80 Installation (cont)


K3VL80 Adaptor Kits
402
317

116 116
314

743 743 743

742
415

Cover Kit SAE ‘A’ T/D Kit SAE ‘B’, ‘BB’, ‘C’ & ‘C4’ T/D Kit

SAE ‘A’ SAE ‘B’


Part Name Qty Cover Kit
T/D Kit T/D Kit

T/D - 29L8TN 29L8TA 29L8TB

O-Ring 1 Item 743 Item 743 Item 743

O-Ring 1 - - Item 742

Screw Hex SHC 4 - - Item 415

Screw Hex SHC 2 Item 402 - -

Subplate 1 - - Item 317

Cover 1 Item 314 - -

Coupling 1 - Item 116 Item 116

SAE ‘BB’ SAE ‘CC’ SAE ‘C4’


Part Name Qty
T/D Kit T/D Kit T/D Kit

T/D - 29L8T2 29L8TC 29L8TC4

O-Ring 1 Item 743 Item 743 Item 743

O-Ring 1 Item 742 Item 742 Item 742

Screw Hex SHC 4 Item 415 Item 415 Item 415

Screw Hex SHC 2 - - -

Subplate 1 Item 317 Item 317 Item 317

Cover 1 - - -

Coupling 1 Item 116 Item 116 Item 116

51
K3VL PUMPS

3-4 K3VL112/140 Installation


K3VL112/140 with Cut-Off / Load Sense Control & Torque Limit
Module (Clockwise Rotation)

152
19

PL/PC
188
77

Dr A
224

PL/PC
125

124
100
100
Tair Dr B

Adjustment screw Max Flow Adjustment


for cut-off pressure Adjustment screw for
Adjustment screw for
differential pressure horsepower setting

PL/PC PL/PC

L
ø32 ø64
88.9 ±0.3

Dr
66.7 ±0.3

Tair
Dr Tair
ø140
200

A
30
30

Dr
Dr

See Port See Port


Details 23 50.8 ±0.3 Details
31.8 ±0.3 106.5 98.5
106.5
250 103 103
250
113.3 113.3 296

Note: for counter clockwise rotation, the suction port ‘B’ and the delivery port ‘A’ are reversed.

52
K3VL PUMPS

3-4 K3VL112/140 Installation (cont)


K3VL112/140 (SAE D 4 BOLT) Mounting Flange & Shaft Options
SAE ‘D’ Type ISO Type
SAE "D" 4 hole Flange
4-ø20 through
SAE J744-152-4 ISO 3019/2
ø152.4h7 -0.063

ø180h8 -0.063
0
161.6

0
45°

ø2
24

0
161.6 ø12.7 -0.5 4-ø18 through 9
92

75

SAE ‘D’ Spline Shaft - Option 'S' SAE ‘D’ Straight Shaft - Option 'K'
ø44.45h7 -0.025

67 67
+0.030
11.11h8 +0.015
0

60
49.3 ±0.13

63
ø44.447

7/16-14UNC-2B
SAE "D" 30° Involute Spline Shaft
SAE "D" Straight Shaft
SAE J744-44-4 13T 8/16 DP
SAE J744-44-1 28
38

ISO Straight Shaft


3 75
+0.018
ø45k6 +0.002

+0.043
0
14h9
ø48.5

M16

Shaft end – ISO 3019/2 G45

36
45

53
K3VL PUMPS

3-4 K3VL112/140 Installation (cont)


Adapter tightening torque:12N.m

K3VL112/140 Rear Port (Not attached but supply with pump)

152
124
30
10 PL/PC

pump rotating direction

220
197.5
125

ø64

31.8±0.3
Dr

88.9±0.3

Tair
95

Dr 4-M14
depth 19
4-M12
depth 22 ø32

280
50.8±0.3 66.7±0.3

62 55

K3VL112/140 Porting Details 106.5 103.5

Main SAE Flanged Ports


Tightening Flange
Des. Port Name Port Size
Torque (Nm) Threads

UNF Threaded Version (‘S’ in position 9 of model code)


A Delivery Port SAE J518C high pressure (code 21) 1¼” 157 ½-13UNC-2B x 22 mm

B Suction Port SAE J518C Std pressure (code 61) 2½” 98 ½-13UNC-2B x 22 mm

Metric Version (‘M’ in position 9 of model code)


A Delivery Port SAE J518C high pressure (code 62) 1¼” 157 M14 x 19 *

B Suction Port SAE J518C Std pressure (code 61) 2½” 98 M12 x 17

* Note: ISO 6162 quotes M12

Auxillary Ports
Tightening
Des. Port Name Port Size
Torque (Nm)

SAE Version (‘S’, ‘K’, ‘C’, ‘R’, ‘U’, ‘X’ or ‘T’ in position 8 of model)
SAE J1926/1 Straight thread O ring boss
Dr Drain Port (x2) 167
¾” OD Tube 11/16-12UN-2B
Load Sensing Port SAE J1926/1 Straight thread O ring boss
PL /PC 12
Pressure Control Port ¼” OD Tube 7/16 -20UNF-2B
SAE J1926/1 Straight thread O ring boss
Tair* Air Bleeder Port 12
¼” OD Tube 7/16 -20UNF-2B
ISO Version (‘M’ in position 8 of model code)
Dr Drain Port (x2) M27 x 2 DIN 3852 167

Load Sensing Port


PL /PC M14 x 1.5 DIN 3852 25
Pressure Control Port

Tair Air Bleeder Port M14 x 1.5 DIN 3852 25


54
K3VL PUMPS

3-4 K3VL112/140 Installation (cont)


K3VL112/140 (2 Bolt) Installation
152
124
for pump rotating 30
direction 10

PL/P C PL/P C

224

197.5
208

204
K3VL140

125
4
ø6
Dr
30

88.9±0.3
B A
B
Dr
Dr
See Port Details
50.8±0.3
20 Tair
48 100 100
136.5
280
326

124
91
PL/P C PL/P C

(UNC screw)
157.5
134.5
30

17.5

Dr
66.7±0.3

A Dr
17.5

Dr
81
2
ø3

31.8±0.3
Tair
136.5 Tair
280 181
103 103
See Port Details 113.3 113.3

218

Dr
PL(PC) A

B
Dr

55
K3VL PUMPS

3-4 K3VL112/140 Installation (cont)


K3VL112/140 Mounting Flange (2 Bolt) and Shaft Options

SAE ‘C’ Type


SAE "C" 2 hole
SAE J744-127-2

ø12 7 -0.5
0
1
ø18

0
12.7 -0.5

56

SAE ‘C’ Spline Shaft - Option 'C' SAE ‘C’ Straight Shaft - Option 'X'
48 48
ø31.75h7 -0.025

43 44
+0.022
0
ø35.2 -0.3
0

7.94 0
ø31.224

M8

SAE "C" 30° Involute Spline Shaft SAE "C" Straight Shaft
SAE J744-32-4 14T 12/24 DP SAE J744-32-1
19
25

SAE ‘CC’ Spline Shaft - Option 'W' SAE ‘CC’ Straight Shaft - Option 'Y'
54 54

48 50
9.53
ø38.1

42.92

ø38.1

SAE "CC" 30°


Involute Spline Shaft 7/16-14UNC-2B
28
SAE J744-38-4 SAE "CC" Straight Shaft
SAE J744-38-1 38
17T 12/24 DP 62

56
K3VL PUMPS

3-4 K3VL112/140 Installation (cont)


K3VL112/140 Through Drive Options

Through Drive ‘A’

Through Drive "A" SAE "A" 2 hole


SAE J744-82-2
+0.035
0

45
°
ø82.55

Tair ø1
Dr 06

Through Drive ‘B’


8 6 - M10 Through Drive "B"
Depth 17
31
307.5

SAE "B" 2 hole


SAE "A" 30° Involute Spline
SAE J744-101-2

+0.035
0

45
°
B ø101.6
ø1
46
Tair Dr

Through Drive ‘BB’ 11 6 - M12


Through Drive "BB"
Depth 17
53
332.5

SAE "B" 30° Involute Spline


SAE "BB" 2 hole SAE J744-22-4 13T DP
SAE J744-101-2
+0.035
0

45
°
ø101.6

ø14
Tair Dr 6

Through Drive ‘C’


Through Drive "C"
11
6 - M12
Depth 25
53
332.5
SAE "C" 2 hole
SAE "BB" 30° Involute Spline SAE J744-127-2
SAE J744-25-4 15T DP
+0.035
0

45
°

B
ø127

Tair Dr ø1
81

14 6 - M16
Depth 30
58
337.5

SAE "C" 30° Involute Spline


SAE J744-33-4 14T 12/24 DP

57
K3VL PUMPS

3-4 K3VL112/140 Installation (cont)


K3VL112/140 Through Drive Options

Through Drive ‘C4’

SAE "C4" 2 hole


SAE J744-127-2
+0.035
0

B
ø127

Tair Dr ø1
62

14 4 - M12
Depth 30
59
337.5

SAE "C4" 30° Involute Spline Through Drive ‘CC’


Through Drive "CC"

SAE "CC" 2 hole


SAE J744-127-2
+0.035
0

45
°
B
ø127

Tair Dr ø1
46
Through Drive "D"

14 6 - M16

Through Drive ‘D’ 337.5


59
Depth 30

SAE "CC" 30° Involute Spline


SA
SAE "D" 4 hole
SAE J744-152-2
+0.035
0

161.6±0.2
ø152.4

Tair Dr

15 4 - M16 Depth 43
161.6 ±0.2
71
350.5

SAE "D" 30° Involute Spline

58
K3VL PUMPS

3-4 K3VL112/140 Installation (cont)


K3VL112/140 Adaptor Kits
402 317
116
116

314
743 743
743
742

415

COVER
Cov KIT SAE"A
SAE ‘A’ T/D KIT SAE ‘B’ T/D Ki
SAE "B" KIT

317 317 317 317

116 116 116


116

743 743 743 743

742 742 742


742

415 415 415 415

S AE ‘BB’ T/D KIT SAE


SAE"C"
‘C’&&“ ‘C4’ T/D KIT SAE
SAE"C
‘CC’ T/D KIT SAE ‘D’
SAE "D T/D KIT

SAE ‘A’ SAE ‘B’ SAE ‘BB’


Part Name Qty Cover Kit
T/D Kit T/D Kit T/D Kit
T/D - 29L8TN 29LHTA 29LHTB 29LHT2

O-Ring 1 Item 743 Item 743 Item 743 Item 743

O-Ring 1 - - Item 742 Item 742

Screw Hex SHC 4 - - Item 415 Item 415

Screw Hex SHC 2 Item 402 - - -

Subplate 1 - - Item 317 Item 317

Cover 1 Item 314 - - -

Coupling 1 - Item 116 Item 116 Item 116

SAE ‘C’ SAE ‘C4’ SAE ‘CC’ SAE ‘D’


Part Name Qty
T/D Kit T/D Kit T/D Kit T/D Kit
T/D - 29LHTC 29LHTC4 29LHT3 29LHTD

O-Ring 1 Item 743 Item 743 Item 743 Item 743

O-Ring 1 Item 742 Item 742 Item 742 Item 742

Screw Hex SHC 4 Item 415 Item 415 Item 415 Item 415

Screw Hex SHC 2 - - - -

Subplate 1 Item 317 Item 317 Item 317 Item 317

Cover 1 - - - -

Coupling 1 Item 116 Item 116 Item 116 Item 116

59
K3VL PUMPS

3-5 K3VL200 Installation


K3VL200 with Cut-Off / Load Sense Control & Torque Limit Module
(Clockwise Rotation)
134
101

PL/PC PL/P C

172.5
149.5
Dr
Dr
53
79.4 ±0.3

ø32

224.5
264.5
Tair
A

Dr

36.5 ±0.3

Depth 24
122
292 224.5
123.3 123.3
264.5

162
30
106.4 ±0.3

10

PL/PC PL/P C
pump rotating direction
K3VL200

K3VL200
239

212.5
219
140

ø76 B A
Tair B

Dr
61.9 ±0.3
Depth 24

17.5
26
122
292
345

221

A
Dr 1.6
PL/P C
134
115
115

1.6
Dr
B

60
K3VL PUMPS

3-5 K3VL200 Installation (cont)


K3VL200 Mounting Flange and Shaft Options

SAE Type

4-ø22 through

224.5
224.5

SAE Spline ‘D’ Shaft SAE ‘D’ Straight Shaft

Ø44.45

11.11
67
75
67
Ø44.447

63
Ø44.45

60
Ø49.3

SAE "D" 30° Involute Spline Shaft


SAE J744-44-4 13T 8/16 DP SAE D Straight Shaft

75 7/16-14UNC-2B
SAE J744-44-1 28

38

SAE Spline ‘F’ Shaft

80
Ø50.1

SAE "F" 30° Involute Spline Shaft 68


SAE J744-50-4 15T 8/16 DP

88

61
K3VL PUMPS

3-5 K3VL200 Installation (cont)


K3VL200 Through Drive Options

Through Drive ‘A’

SAE “A” 2 hole


K3VL200 SAE J744-82-2

+0.035
2-M10
B
x 20 deep

82.55 0
Tair

Dr
106
8
Through Drive ‘B’ 365 37 SAE “A” 30 deg Involute Spline

SAE “B” 2 hole


K3VL200
SAE J744-101-2
8-M12 Through
45

ø146
+0.035

B
101.6 0

Tair
45

Dr

59 8 SAE “B” 30 deg Involute Spline


384
Through Drive ‘BB’

SAE “B” 2 hole


K3VL200
SAE J744-101-2
8-M12 Through
45

ø146
+0.035

B
101.6 0

Tair
45

Dr

58.5 10.5
Through Drive ‘C’ 384
SAE “BB” 30 deg Involute Spline

SAE “C” 2 hole


SAE J744-127-2
K3VL200
45
+0.035

B
127 0

ø181
Tair

Dr
6-M16 Through
8
384 58 SAE “C” 30 deg Involute Spline

62
K3VL PUMPS

3-5 K3VL200 Installation (cont)


K3VL200 Through DriveOptions

Through Drive ‘C4’

SAE “C” 4 hole


SAE J744-127-4
K3VL200

+0.035

114.5
B

127 0
Tair

Dr
4-M12 Through
14 114.5
Through Drive ‘CC’ 384 58
SAE “C” 30 deg Involute Spline

SAE “C” 2 hole


SAE J744-127-2
K3VL200
45
+0.035

B
127 0

Tair ø181

Dr 6-M16 Through
14
58 SAE “CC” 30 deg Involute Spline
384
Through Drive ‘D’

SAE “C” 4 hole


SAE J744-152-2
K3VL200
+0.040

161.6
152.4 H7 0

Tair

Dr

4-M16 through 161.6


8
Through Drive ‘E’ 397 75
SAE “D” 30 deg Involute Spline
SAE “E” 4 hole
SAE J744-165-4

K3VL200
+0.040

224.5 ±0.2
165.1 H7 0

B
Tair

Dr

8 224.5 ±0.2
397 75 4-M20 depth 38
SAE “D” 30 deg Involute Spline

63
K3VL PUMPS

3-5 K3VL200 Installation (cont)


Main SAE Flanged Ports
Tightening Flange
Des. Port Name Port Size
Torque (Nm) Threads

UNC Threaded Version (‘S’, ‘K’ in position 9 of model code)


5/ -11UNC
A Delivery Port SAE J518C high pressure (code 62) 1½” 235 8 -2B
5/ -11UNC
B Suction Port SAE J518C Std pressure (code 61) 3” 235 8 -2B

Metric Version (‘M’ in position 9 of model code)


A Delivery Port SAE J518C high pressure (code 62) 1½” 235 M16

B Suction Port SAE J518C Std pressure (code 61) 3” 235 M16

Auxillary Ports
Tightening
Des. Port Name Port Size
Torque (Nm)
SAE Version (‘S’, ‘K’ in position 8 of model)
SAE J1926/1 Straight thread O ring boss
Dr Drain Port (x2) 167
¾” OD Tube 11/16-12UNF-2B
Load Sensing Port SAE J1926/1 Straight thread O ring boss
PL /PC 12
Pressure Control Port ¼” OD Tube 7/16 -20UNF-2B
SAE J1926/1 Straight thread O ring boss
Tair Air Bleeder Port 12
¼” OD Tube 7/16 -20UNF-2B

64
K3VL PUMPS

3-5 K3VL200 Installation (cont)


K3VL200 Through Drive Kits

402

314

743

COVER Kit SAE “A” T/D Kit SAE “B” T/D Kit SAE “BB” T/D Kit

SAE “C” & “C4” T/D Kit SAE “CC” T/D Kit SAE “D” T/D Kit SAE “E” T/D Kit

Part Name Qty SAE ‘A’ SAE ‘B’ SAE ‘BB’ SAE ‘C’

T/D Kit - - - - -

Coupling K3VL200 1 Item 116 Item 116 Item 116 Item 116

Sub Plate K3VL200 1 Item 317 Item 317 Item 317 Item 317

SHCS 8 Item 402 Item 415 Item 415 Item 415

O-Ring 1 Item 743 Item 743 Item 743 Item 743

O-Ring 1 Item 742 Item 742 Item 742 Item 742

Part Name Qty SAE ‘C4’ SAE ‘CC’ SAE ‘D’ SAE ‘E’

T/D Kit - - - - -

Coupling K3VL200 1 Item 116 Item 116 Item 116 Item 116

Sub Plate K3VL200 1 Item 317 Item 317 Item 317 Item 317

SHCS 8 Item 415 Item 415 Item 415 Item 415

O-Ring 1 Item 743 Item 743 Item 743 Item 743

O-Ring 1 Item 742 Item 742 Item 742 Item 742

65
K3VL PUMPS

3-6 K3VL200H Installation


N Type Through Drive
Approx. displacement change per
revolution of screw : 15.3cm3

Lock-nut tightening torque=235N.m

140
ø165.1 -0.05
0

PB
53

Dr

119
SAE ‘E’ : 4 hole
SAE J744-164-4 26

122
0
16 -0.05 301

424

294 4-M16 Depth 26


120.7 ±0.2
Dr

ø9
0
69.9 ±0.2

B
6.5

A
Dr

2-M8 the thread to remove seal cover.


(The position of thread might be different.)

Adjustment screw for cut-off pressure Adjustment screw for differential pressure
Approx. pressure change per revolution Approx. pressure change per revolution 134
of screw : 10MPa of screw : 1.4MPa
101

PL PC
187.5

172.5

148.5

Dr

Dr
53

8
ø3
79.4 ±0.2

Tair
264.5
224.5

Dr

B
36.5 ±0.2 122
4-M16 Depth 26 224.5
276
123.3 123.3

264.5

4-ø22 Through
Recommend
Tightening torque : 435.m
for M20 of strength class 10.9 of JIS
Recommend to use washers

66
K3VL PUMPS

3-6 K3VL200H Installation (cont)

SAE 'A' Throughdrive


Please contact KPM UK for dimensions. l

SAE 'B' Throughdrive

09
±1
+0.04

45 0
ø101.6 h7 0
Tair PB

45 ±
ø14

0.2

0 10
9
Dr SAE ‘B’ : 2 hole
SAE J744-101-2
8-M12 Depth 25
11.7

60
SAE ‘B’ 30deg INVOLUTE SPINE
476 SAE J744-22-4 13T 16/32 DP

SAE 'B-B' Throughdrive


09
±1
+0.04

45 0
ø101.6 h7 0

Tair PB
45 ±

ø14

0.2
0 10
9

Dr SAE ‘B’ : 2 hole


SAE J744-101-2
8-M12 Depth 25
11.7

60
SAE ‘BB’ 30deg INVOLUTE SPINE
476 SAE J744-25-4 15T 16/32 DP

67
K3VL PUMPS

3-6 K3VL200H Installation (cont)


SAE 'C' Throughdrive

+0.04
ø181 ±0
.2

114.5 ±0.2
ø127 h7 0
Tair PB

2-M16 Depth 25
Dr SAE ‘C’ : 2 hole/4 hole
SAE J744-127-2/J744-127-4
4-M12 Depth 25
11.7
114.5 ±0.2
63
SAE ‘C’ 30deg INVOLUTE SPINE
476 SAE J744-32-4 14T 12/24 DP

SAE 'C4' Throughdrive


Please contact KPM UK for dimensions. l

SAE 'C-C' Throughdrive


+0.04

ø181 ±0
.2
114.5 ±0.2
ø127 h7 0

Tair PB

2-M16 Depth 25
Dr SAE ‘C’ : 2 hole/4 hole
SAE J744-127-2/J744-127-4
4-M12 Depth 25
11.7
114.5 ±0.2
63
SAE ‘CC’ 30deg INVOLUTE SPINE
476 SAE J744-32-4 14T 12/24 DP

68
K3VL PUMPS

3-6 K3VL200H Installation (cont)


SAE ‘D’ Throughdrive

+0.04

161.6 ±0.2
ø152.4h7 0
Tair PB

Dr

SAE ‘D’ : 4 hole


SAE J744-152-4
11.7
4-M16 Depth 38 161.6 ±0.2
79
SAE ‘D’ 30deg INVOLUTE SPINE
489 SAE J744-47-4 13T 8/16 DP

SAE 'E' Throughdrive


+0.04

224.5 ±0.2
ø165.1h7 0

Tair PB

Dr

SAE ‘E’ : 4 hole


SAE J744-165-4
11.7 224.5 ±0.2
4-M20 Depth 40
79
SAE ‘E’ 30deg INVOLUTE SPINE
489 SAE J744-47-4 13T 8/16 DP

Part Name Qty SAE ‘A’ SAE ‘B’ SAE ‘BB’ SAE ‘C’

Coupling K3VL200 1 Item 116 Item 116 Item 116 Item 116

Sub Plate K3VL200 1 Item 317 Item 317 Item 317 Item 317

SHCS 8 Item 407 Item 407 Item 407 Item 407

O-Ring 1 Item 743 Item 743 Item 743 Item 743

O-Ring 1 Item 742 Item 742 Item 742 Item 742

Part Name Qty SAE ‘C4’ SAE ‘CC’ SAE ‘D’ SAE ‘E’

Coupling K3VL200 1 Item 116 Item 116 Item 116 Item 116

Sub Plate K3VL200 1 Item 317 Item 317 Item 317 Item 317

SHCS 8 Item 407 Item 407 Item 407 Item 407

O-Ring 1 Item 743 Item 743 Item 743 Item 743

O-Ring 1 Item 742 Item 742 Item 742 Item 742

69
K3VL PUMPS

3-7 Electrical & Hydraulic Displacement Control


Installation (Type Q0, E*)

Pi

B C F

A
Pi

Pc

D
E

Installation Dimensions (mm)

Pump Size A B C D E F G

K3VL45/60 21 52 90 187 157 226 210

K3VL80 25 59 83 202 172 233 217

K3VL112/140 38 64 78 244 214 247 231

K3VL200(H) 57 61 80 258 229 257 249

70
K3VL PUMPS

3-8 Unloading & Proportional Pressure Control


Installation
Unloading valve module (Type N, M) Proportional pressure module (*V)

Pump Size A B Pump Size A B

K3VL45/60 169 155 K3VL45/60 179 233

K3VL80 169 166 K3VL80 179 244

K3VL112/140 202 190 K3VL112/140 212 280

K3VL200(H) 212 205 K3VL200(H) 222 295

A : Distance between the centre line of the pump and the top of the bolt head for the cut off regulator.
B : Distance between the centre line of the pump and top of the solenoid valve.

Unloading valve module (Type N, M)

B
A

Proportional pressure module (*V)

B
A

71
K3VL PUMPS

3-9 Power Shift Control Installation

/2-** Hydraulic Power Shift /3-** Electronic Power Shift

Pump Size A B C Pump Size A B C

K3VL80 182 59 5 K3VL80 193 80 3.5

4B 33.7 4B 18.5
K3VL112/140 224 59 K3VL112/140 235 80
2B 63.7 2B 48.5

K3VL200(H) 239 59 51.5 K3VL200(H) 249.5 80 36

B (/2-**) B (/3-** )

C
A

72
K3VL PUMPS

3-10 Calibration of Regulators


Lock nut
Max displacement
Pump K3VL45 K3VL60 K3VL80 K3VL112 K3VL140 K3VL200(H)
adjustment
Q max
Adj. screw Allen key size mm 8 8 8 10 10 10 adjuster

Displacement change
cm3 4.9 6.1 6.0 11.5 12.0 15.3
per turn
Adjustable range of
cm3 16-45 24-60 35-80 56-112 70-140 100-200
displacement
Length of adjustment
mm 0.5-12.1 0.5-12.1 0.5-15.0 3.8-16 1.0-16 8.9-25.3
range (L)

Lock nut size mm 24 24 24 30 30 30

Lock nut tightening


Nm 128 128 128 235 235 235
torque

K3VL28/45 K3VL112
Regulator Adjustment Pump Pressure cut off
/60/80 /140/200
adjuster screw
Adjustment screw Allen key size mm 4 4

Pressure cut off change per turn bar 80 100

Differential pressure change per


bar 13 14
turn

Lock nut size (across flats) mm 8 8

Lock nut tightening


Nm 16 16
torque
*1 Clockwise rotation of a screw produces an increase of the adjustment
Lock nut
Differential pressure
Torque limiter adjustments
adjuster screw

Outer spring adjuster screw: external hex mm 27

Outer spring lock nut size mm 41

Outer spring lock nut tightening torque Nm 102

Inner spring adjuster screw: internal hex mm 4

Inner spring lock nut size mm 13

Inner spring lock nut tightening torque Nm 16

Torque limiter module Torque limiter curve

uter spring
lo nut
adjustement of
uter spring external spring
adjuster s rew
adjustement of
Flow

external spring +
inner spring
nner spring
adjuster s rew
nner spring
lo nut
Pressure

73
K3VL PUMPS

NOTES

74
K3VL PUMPS

NOTES

75
HMF MOTORS

KAWASAKI PRECISION
MACHINERY (UK) LTD
Ernesettle, Plymouth
Devon, PL5 2SA, England

Tel: +44 1752 364394


Fax: +44 1752 364816
Mail: info@kpm-uk.co.uk
Website: www.kpm-eu.com

OTHER GLOBAL SALES OFFICES

JAPAN
Kawasaki Heavy Industry Ltd, Precision Machinery Ltd. Tokyo Office World
Trade Center Bidg.
4-1 Hamamatsu-cho
2-chome, Minato-ku
Tokyo 105-6116
Japan
Tel: +81-3-3435-6862
Website: www.khi.co.jp/kpm

U.S.A
Kawasaki Precision Machinery (U.S.A.), Inc.
3838 Broadmoor Avenue S.E.
Grand Rapids
Michigan 49512
U.S.A.
Tel: +1-616-975-3101
Website: www.kpm-usa.com

CHINA
Kawasaki Precision Machinery Trading (Shanghai) Co., Ltd. 17th Floor (Room
1701), The Headquarters Building No168 XiZang Road (M)
Huangpu District
Shanghai 200001
China
Tel: +86-021-3366-3800

KOREA
Flutek, Ltd.
192-11, Shinchon-dong
Changwon
Kyungnam 641-370
Korea
Tel: +82-55-286-5551
Website: www.flutek.co.kr

The specified data is for product description purposes only


and may not be deemed to be guaranteed unless expressly
confirmed in the contract.

Data sheet: P-2001/04.18