TRFC-E

Description
The Electric Tubing Retrievable FloController (TRFC-E) device is the primary active downhole component in the intelligent completion. This is
a downhole infinitely variable controlled choke activated from surface. Each TRFC-E integrates an electro-mechanical adjustable choke,
multiple pressure/temperature sensors, and a mass-flow computation, all powered from the surface through a single Permanent Downhole
Cable (PDC). The TRFC-E enables adjustment of the inflow/outflow characteristics without the use of conventional intervention methods.
Multiple TRFC-E's may be run providing zonal control and monitoring. Each TRFC-E is independently addressable, giving the operator the
ability to adjust any of the zones in the well on command. Power required to drive the TRFC-E actuator and the sensors is transmitted down
the single PDC line. Data from the on-board sensors and diagnostic systems is sent back to the Surface Unit over the same PDC line utilizing
the proprietary telemetry system. As many TRFC-E as necessary can be placed on the same electric cable.

Valve:
On command from the Surface Unit, the TRFC-E will adjust the choke with the resultant position confirmed back to the Surface Unit. The
infinitely adjustable choke enables precise regulation of the volume of produced or injected fluid flow through the valve, with simultaneous
full sensory monitoring of the downhole conditions.

Tubing Pressure, Temperature & Flow:


The TRFC-E is designed with integral Schlumberger Permanent Quartz Gauges (PQG), pressure and temperature measurement gauges. These
high accuracy, high resolution sensors are state-of-the-art. They have demonstrated reliable field service worldwide as stand-alone
permanent downhole gauges. The integral FloWatcher uses a Venturi flowmeter with two PQGs to measure the pressure drop across the
Venturi. The Venturi is retrievable by conventional coiled tubing or slickline operations. This offers flexibility to suit well performance over
time.

Annulus (Sandface) Pressure & Temperature:


The TRFC-E has a 'PQG' sensor ported to gather external (annulus) pressure data. The annulus pressure gauge can supply packer test
pressure during completion, sandface pressure during production, and pressure build-up data during shut-in.

Valve Section
Maximum operating temperature 150 ˚C
Maximum working pressure 6300 psi differential. 10 lb. psi absolute
Tensile rating (no differential pressure) 350,000 lbs
Tool dimensions Min ID – 4.31”, Max OD – 8.3”
System reliability 90% after 5 yrs, 4 zones
Flow wetted material NACE MR 01-75
Power required at wellhead -250 400 VDC, 1 amp max
Communication and Power Direct link or POD Interface

FloWatcher Section
Measurement Maximum Resolution Full scale accuracy Drift/yr @150˚
Pressure 15,000 psi 0.01 psi < +/- 3 psi +/- 5 psi/yr
Temperature 150˚C +/-0.001˚C +/- 1.0 ˚C +/- 0.05 C/yr
Flow 50,000 barrels/day 5% achievable
"All data herein is estimated and subject to change without notice pending final design"
Venturi landing profile
Venturi throat pressure port
Tubing pressure port
Annulus pressure port

(Venturi Not Shown)