Sie sind auf Seite 1von 7

<<Contents>> <<Index>>

General US300FM
Specifications Ultrasonic Flowmeter

GS 01G05B03-01E

■ General
US300FM is a ultrasonic flowmeter that measures the
flow in a pipe fully filled with liquid.
It can be fixed to the wall or to the 2B pipe with optional
pipe mounting fixture. The housing and transducers are
made for rough industrial environment.
The measuring principle is based on the influence of the
flowing fluid to the travelling time of sound. The sound is
transmitted through the pipe and the transit time differ-
ence between the forward and backward beams is used
to determine the flow velocity (transit time method).
The measurement is non-intrusive. No cutting of the pipe
is necessary. The measurement is independent of fluid
pressure or conductivity. Owing to its clamp on transduc-
ers the installation is easy.
For the hygienic measurement, there is no risk of
contamination and suitable for ultra clean liquids as the Pipe size: 25 to 6500 mm
transducers do not touch the liquid. Also, there is no risk Pipe and lining material:
of corrosion when used with aggressive media. Carbon steel, Stainless steel, Grey cast iron,
Ductile iron, Copper, Glass, PVC, etc
The instrument can work with up to two pairs of transduc-
Flow velocity range: 0.01 to 25 m/s
ers (optional). This enables you to measure the average Resolution: 0.025 cm/s
flow for disturbed flow profile (two path measurement), Accuracy:
the differential flow of two independent flows, or simply
1 to 3% of reading depending on application
two different flows independently. Measuring cycle:
100 to 1000 Hz (when only one channel input)
■ Features Straight pipe run in the upstream:
• Maximum two channel inputs (two path measurement) 10 to 50 diameters, depending on the kind of flow
possible disturbance
• Two current outputs maximum (The flow data and the
sound speed in the liquid can be assigned at the same ● Ultrasonic flowmeter (US300FM)
time) Construction:
• Small and light (depth about 7 cm, weight about 2.8 kg Housing material:Aluminium (powder coated)
for the main unit) Water and dust-proof:
• Wall mounting or optional 2B pipe mounting IP65 (EN60529), IPx5 (JIS C 0920)
• Interactive setup menu for easy installation Mounting method:
• Three types of transducers cover the pipe sizes from Wall mounting
25mm to 6500 mm. For the fluid temperature, one for 2B pipe mounting
general temperature (up to 130 deg C) and the other for Input:
high temperature (up to 200 deg C) available. Number of input channels:
• Owing to its unique digital signal processing the anti 1 or 2 (Channel A, Channel B)
airbubble performance is high Output:
Current output:1 to 2 outputs
■ Standard Specifications Range:4 to 20 mA
Flow velocity, volume flow, or sound speed in the
● General liquid can be freely assigned
Fluid: Liquid (Turbidity < 10,000 mg/L, fluid sound speed Frequency output:
800 to 3500 m/s) 0 or 1 output (total output number of current and
Measured quantity: frequency outputs is maximum 2)
Volume flow, mass flow (by setting density), flow Range:0 to 1 kHz
velocity, sound speed in the fluid Contact type: Open-collector, 24 V/4 mA
Measuring principal: The value indicates instantaneous flow rate.
Transit time method using ultrasonic signal

GS 01G05B03-01E
©Copyright Sep. 2001(YG)
1st Edition Sep. 17 2001(YG)
<<Contents>> <<Index>> 2
Binary output (pulse or alarm): Power supply:
0 to 2 outputs Power supply voltage:
Contact type: Open-collector, 24 V/4 mA 100 to 240 V AC, or 24 V DC
The output values are selectable for each output. Power consumption: less than 15W
The pulse outputs indicate the total volume flow Safety and EMC standard:
(0.01 to 1000/unit) with pulse width 80 to 1000 ms. General safety: EN61010 (CE marking)
Terminal type: EMC regulation: EN50081 (CE marking)
Screw-type pillar terminals AS/NZS 2064 (C-Tick mark)
Display and Setting: Operating conditions:
LCD display: Ambient temperature: –10 to +60 deg C
2⫻16 characters LCD with back light
● Transducers (US300FT)
Two values can be displayed at the same time.
Keyboard: Type of usage:
15 keys (numeric and function keys) Dust and water-proof:
Easy operation by the interactive menu display General purpose:
Parameter setting storage function: IP65 (EN60529), IPx5 (JIS C 0920)
Storage of pipe and fluid parameters (Maximum 80 Immersible:
different settings) IP67 (EN60529), IPx7 (JIS C 0920)
Calculation function: Pipe size type:
Flow value: Medium size: 25 to 400 mm
Flow velocity Large size: 100 to 2500 mm
Volume flow or mass flow rate and totalization Very large size: 2000 to 6500 mm
(both positive and negative flow totalization) Fluid temperature:
Sound velocity: General temp. type: –30 to +130 deg C
Sound velocity in the fluid High temp. type: –30 to +200 deg C
Calculation for the two flow inputs: Construction:
Two values from average, sum, or difference of the Case material: Stainless steel
channel A and channel B inputs are available freely Contact surface material:
Output assignment: General temp. type: PEEK (Poly Ether Ether Keton)
Calculated values above except for the wall thickness High temp. type: Polyimid
can be freely assigned to the actual outputs Cable protection material:
(two channel-independent outputs available) Stainless flexible tube(from sensor blocks to junction
Output damping: 0 to 100 seconds box)
Alarm: Junction box:
Alarm items: A junction box is equipped at the cable end
High limit, low-limit, flow direction change,
quantity limit (for batch operation), error ● Connection cable (US300FC)
(measurement impossible) Connection cable is used from the junction box to
Output hold type: Non-hold or Hold the main unit. The length is from 1 to 300 m.
Output contact direction:
Normal Open or Normal Close ● Accessories
Data logging function (for maintenance purpose only): Standard accessories for US300FM:User’s manual
Function: Others (fixing hardware, couplant, etc):
Store measured values in the internal memory Some are selectable in the model and suffix code
(used with communication function below) (see next page) of the main unit or transducers, or
Memory size: 27,000 values separate orders are also possible
Communication function (for maintenance purpose only):
䊉 Data transfer software (Will be available soon)
On-line/Off-line output of the measured values to
personal computers or serial printers Download and upload of the parameters or
Type: RS232 download of logging data via RS232 communica-
Connector: D-sub 9-pin connector, male tion port (for maintenance purpose only)

Time-programmable measurement function: Standard accessories:


Automatic start and stop of the measurement using RS232 cable and RS232 adapter 9/25
internal clock. Operating system:
Can be used with data logging function or Windows 95, 98, ME, NT, 2000
communication Language:
English / German version

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 01G05B03-01E 1st Edition Sep.17,2001-00
<<Contents>> <<Index>> 3
■ Model and Suffix Code
Ultrasonic flowmeter Transducers
Model Suffix code Specification Model Suffix code Specification

US300FM · · · · · · · · · · · · · · · Ultrasonic flowmeter US300FT · · · · · · · · · · · · · · · · Transducers

Output -A1 · · · · · · · · · · · · One current output Usage -G · · · · · · · · · · · · · General purpose (IP65)

-A2 · · · · · · · · · · · · Two current outputs -W · · · · · · · · · · · · · Immersible (IP67)

Power Supply 1·········· 100 to 240 V AC Pipe Size / BG · · · · · · · · · · · Medium & General (with 3 m
Fluid cable) (Note)
4·········· 24 V DC Temperature
BH · · · · · · · · · · · Medium & High (with 3 m cable)
Input Channel -1 · · · · · · · · One input channel (one-path) (Note)
-2 · · · · · · · · Two input channels (two-path) CG · · · · · · · · · · · Large & General (with 4.4 m
cable) (Note)
Electrical connection -4 · · · · · · ISO M20 x 1.5 female
CH · · · · · · · · · · · Large & High (with 4.4 m cable)
Option /PU1 · · One binary (pulse or alarm) (Note)
output (open-collector) (Note)
DG· · · · · · · · · · · Very large & General (with 12 m
/PU2 · · Two binary (pulse or alarm) cable) (Note)
outputs (open-collector) (Note)
(Note)
/FQ1 · · Frequency output (open- B: Medium size (25 to 400 mm)
collector, 0 to 1 kHz) (Note) C: Large size (100 to 2500 mm)
/BGT · · Tag number on nameplate (in D: Very Large (2000 to 6500 mm)
the nameplate label, maximum
G: General temp. (–30 to +130
16 characters)
deg C)
/SCT · · Tag number on stainless steel H: High temp. (–30 to +200 deg C)
tag plate (maximum 16
-N· · · · · · · · · · Always N
characters)
Fixing band, strap B · · · · · · · · For 25 to 400 mm
/PMT · · Pipe mounting fixture
and clips Two fixing bands
T01.EPS
One strap of 10 m length
(Note) Option /PU1 and /PU2 are exclusive. Two clips of medium type
Option /FQ1 is not selectable for two current output Two clips of large type
(-A2) models
C · · · · · · · · For 1400 to 2800 mm
One strap of 20 m length
Connection cable Two clips of large type
D · · · · · · · · For 2800 to 6500 mm
Model Suffix code Specification Two straps of 20 m length
Two clips of large type
US300FC · · · · · · · · · · · · · · · Connection cable
N· · · · · · · · None
Length -Gxxx · · · · · · · · · xxx: Cable length 001 to 300[m]
T02.EPS Acoustic couplant G · · · · · · General temperature type (–30
to +130 deg C)
Data transfer software (Will be available soon) H · · · · · · High temperature type
(–30 to +200 deg C)
Model Suffix code Specification N · · · · · · None
US300SA · · · · · · · · · · · · · · · Data transfer software Option /TTP · · Transducer tag plate
(Windows version) Including (maximum 16 characters)
connecting kit (RS232 cable for T04-1.EPS
connection with IBM-PC, RS
232 adapter 9/25)
Language -1 · · · · · · · · · · · · · · English / German version
00 · · · · · · · Always 00
T03.EPS

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 01G05B03-01E 1st Edition Sep.17,2001-00
<<Contents>> <<Index>> 4
Accessories (for ultrasonic flowmeter US300FM) Accessories (for transducers US300FT)

Model Description Model Description

USPA201 Pipe mounting fixture(to add the option /PMT) USPA001 Fixing strap (10 m length)
T05.EPS USPA002 Fixing strap (20 m length)
USPA011 Fixing clips
Accessories (others) (medium type, for pipe size 40 to 100 mm, set of two
clips)
Model Description
USPA012 Fixing clips
USPA401 RS232 cable (large type, for pipe size 100 to 6500 mm, set of two
USPA402 RS232 adapter 9/25 clips)

USPA411 Measuring tape USPA021 Fixing band


T06.EPS
(only for pipe size 25 to 50 mm)
USPA031 Fixing chain
(for pipe size 25 to 600 mm)
USPA032 Extensional fixing chain
(2 m length, equal to +600 mm diameter)
USPA033 Repair set for fixing chain
USPA054 Mounting fixture standard type
(for transducers medium pipes size type, temperature
range –30 to +200 deg C, set of two blocks)
USPA055 Mounting fixture magnetic general temperature type
(for transducers medium pipe size type, temperature
range –30 to +100 deg C, set of two blocks)
USPA057 Mounting fixture standard type
(for transducers large or very large pipe size type,
temperature range –30 to +200 deg C, set of two blocks)
USPA058 Mounting fixture magnetic general temperature type (for
transducers large or very large pipe size type,
temperature range –30 to +100 deg C, set of two blocks)
USPA073 Additional magnets for mounting fixture magnetic
general temperature type
(for transducers medium pipe size type, temperature
range –30 to +100 deg C, set of two magnets)
USPA075 Additional magnets for mounting fixture magnetic
general temperature type
(for transducers large or very large pipe size type,
temperature range –30 to +100 deg C, set of two
magnets)
USPA081 Ruler for the mounting fixture
(marked length 120 mm)
USPA082 Ruler for the mounting fixture
(marked length 330 mm)
USPA091 Acoustic couplant for general temperature
(100 g, –30 to +130 deg C)
USPA092 Acoustic couplant for high temperature
(100 g, –30 to +200 deg C)
F07.EPS

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 01G05B03-01E 1st Edition Sep.17,2001-00
<<Contents>> <<Index>> 5
■ Installation Condition
Notice for Installation
(1) The pipe must be always fully filled with liquid.
(2) It is recommended to take some straight pipe run in the upstream and downstream direction of the transducers as shown
below.

Piping layout and straight pipe run (D: Pipe diameter)

Type Upstream Direction Downstream Direction


90°-elbow L>10D L>5D
L>5D

L > 10 D

T-section L>50D L>10D


L > 50 D L > 10 D

Diffuser L>30D L>5D


L > 30 D L>5D

Reducer L>10D L>5D


L > 10 D L>5D

Valve L>40D L>10D


L > 40 D L > 10 D

Pump L>50D

L > 50 D

F01.EPS

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 01G05B03-01E 1st Edition Sep.17,2001-00
<<Contents>> <<Index>> 6
■ Dimensional Drawings
Ultrasonic flowmeter US300FM Unit: mm (inch)

280 (11.0)
265 (10.4)
4-M4
200 (7.9)

163 (6.4)
4-M20x1.5 female
2B Pipe mounting fixture
(Option)
71 (2.8)

F01-E.eps

Weight: 2.8 kg (6.17 lb)

Transducers US300FT-ⵧBⵧ
59 (2.3) 80 (3.2)
X Y
(0.9)
22

;;
; V
VS
75 (3.0)

3
4
GN
5 43 (1.7)
;;
6
RS

;;
; R
(0.7)
18

F02-01E.eps

Transducers US300FT-ⵧCⵧ, US300FT-ⵧDⵧ


59 (2.3) 80 (3.2)
X Y
34 (1.3)

;;;
;;V
;;;VS
75 (3.0)

3
4
GN
5
60 (2.4)
;;; 6

;;;
;;
RS
30(1.2)

F02-02E.eps

Transducers X m (inch) Y m (inch) X+Y m (inch) Weight kg (lb)


US300FT- 䊐B䊐 2.0 ( 78.7) 1.0 ( 39.4) 3.0 (118.1) 0.9 (1.98)
US300FT- 䊐C䊐 2.0 ( 78.7) 2.4 ( 94.5) 4.4 (173.2) 1.5 (3.31)
US300FT- 䊐D䊐 5.0 (196.9) 7.0 (275.6) 12.0 (472.4) 2.5 (5.51)
T01-01E.eps

Connection Cable US300FC

Junction box side Main unit side


;;; ;;; ;;; ;;;
;;; ;;; ;;; ;;;
;; ;; 55
(2.2)
60
(2.4)
;; ;;

US300FC-G䊐䊐䊐
(The length is from 1 to 300m.)

ø12
(0.5) F05-E.eps

Weight: approx. 167 g/m (0.37 lb/m)

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 01G05B03-01E 1st Edition Sep.17,2001-00
<<Contents>> <<Index>> 7
■ Wirings
Terminal Layout
For AC power supply For DC power supply

AGN

BGN
ARS

BRS
AVS

BVS

P4+
P1+
P2+

P5a
P3+

P6a
P7a
AR

BR
AV

BV

A+
; ;

B-
SB4
SB1
SB2
SB3
SA4
SA3
SA1
SA2

P5b
P6b
P7b
101
103

P4-
P1-

P3-
P2-

PE

L+
PE

L-
L1
N
F04-E.eps e

Terminal Designations

Terminal Terminal
Description Name Description
Name
AV P1+
Upstream transducer signal for channel A Current output (+,–)
AVS P1–
AR P2+ Current output (+,–) or Frequency output(+,–)
Downstream transducer signal for channel A depending on the specification (optional)
ARS P2–
BV P5a Binary (pulse or alarm) output depending
Upstream transducer signal for channel B
BVS P5b on the specification (optional)
BR P6a
Downstream transducer signal for channel B Same as above
BRS P6b
SA1 PE Earth
SA2 Sensor ROM for channel A N Neutral
SA3 (connected when shipped) L1 AC power supply (100 to 240 V AC)
SA4 (Earth)
PE
SB1 L– DC–
SB2 Sensor ROM for channel B L+ DC+ (24 V DC)
SB3 (connected when shipped) T02-E.eps

SB4

Ordering Information
Specify the following when ordering.
2. Tag number (when necessary)
Maximum sixteen (16) characters for the cases below.
1. Model, suffix and option code
(1) In the nameplate label of the main unit US300FM
(1) First, specify the main unit US300FM, the transduc-
(necessary to specify the option /BGT at the same
ers US300FT (one pair of transducers when using
time)
only one channel, or two pairs when using two
(2) In the stainless steel tag plate hanged onto the main
channels), and the connection cable US300FC (one
unit US300FM (necessary to specify the option /SCT
cable when using only one channel, or two cables
at the same time)
when using two channels) . The transducers and
(3) In the tag plate for the transducers US300FT
cables can be added later but the number of
(necessary to specify the option /TTP at the same
channels for the main unit can not be added later.
time)
(2) Specify the accessories when necessary or suitable.
For example we may use “fixing chain” instead of
“fixing strap” to fix the transducers to the pipe. Please
consult us for the details.

All Rights Reserved. Copyright © 2001, Yokogawa Electric Corporation GS 01G05B03-01E 1st Edition Sep.17,2001-00