Rotameter ®
Specifications
The flow is indicated by the top of the float and can be read from
the standard scale on the metering tube or a from connected
scale.
FEATURES
● Large selection of measuring ranges
● Anti-static metering tubes for measurement of lower gas flow
● High accuracy by free rotating float even at low flow rates
● Low pressure loss
● Visual check of the medium
● Non-powered local indication
● Large selection of scales
● High corrosion resistance
● Exact scale calculation at changed process medium
according to VDE/VDI guidelines 3513 with the use of the
flow table (option /PT)
STANDARD SPECIFICATIONS
Measurable flow rates Max. Temperature
- Water (20 °C) : 0,002 l/h to 16 m3/h - Standard : 100 °C
- Air (20 °C ; 1 bar abs.) : 0,1 l/h to 60 m3/h - with option /MV : 130 °C
Measuring range : metering tube G 10:1 Material process connection
metering tube L 20:1 - DIN loose flange : steel
Metering tubes : L6; L7; G0 to G5 - Gasket : 1.471: steel; PTFE; ceramic
Accuracy : according to VDI 3513 Housing material: : steel; plastic;
class 1,6 (gasket PTFE)
Max. pressure Length : approx. 500 mm
Weight : 6 to 15 kg
Metering tube L6; L7 G0;G1 G2 G4 G5
(depending on design)
Pmax (bar) 16 10 8 6 5
YOKOGAWA GS 1R1B6-E-H
3rd. edition
ROTA YOKOGAWA
2
OPTIONS
LIMIT SWITCH (OPTION CODE: /GI1 TO /GI4) LIMIT SWITCH (OPTION CODE: /GM1 AND /GM2)
(for floats of Mumetal or PVDF with a Fe-core only from (for float with magnet only and flow Qmin > 2.5 l/h water or
Qmin = 0.004 l/h water or 0.3 l/h air) 100 l/h air)
Type : bistable inductive ring initiator Type : reed contact with bistable switching
according to DIN 19 234 (NAMUR) Max. switching voltage : 230 V
Supply voltage range : 4.5 V to 13 V DC Max. switching current : 0.6 A
Consumption : for floats Max. switching capacity : 12 VA or 12 W
below ring initiator: < 1mA Temperature range : -10 °C to +70 °C
over ring initiator: > 2.2 mA Protection : IP 65
Temperature range : -25 °C to +70 °C Internal capacity : 0 nF
Protection : IP 67 according to DIN 40 050 Internal inductivity : 0 mH
Cable connection : 1 x 0.14 mm2 with screen 0,4 mm2; Electrical connection : LIYY 2 x 0.34; 1 m long
2 m long Weight : 35 g
max. capacitance cable connection < 200 µF
GS 1R1B6-E-H
3
MODEL SPECIFICATIONS
GS 1R1B6-E-H
4
Description
Length metering tube 300 mm ................... L
(type) 300 mm .................... G
Diam. metering tube 10 mm to 95 mm ................... k
Metering tube cone see flow table .............................................. kk
Metering tube- Medium- scale on metering tube (mm division3) .................... G
scale connection scale with mm division (recommended) ........ A
metering tube with mm division only ............................... N
Float 1.4571 ........................................................................................... SS
material Titanium ......................................................................................... TT
Mumetal (for limit switches /Gl1; /Gl2 and /Gl4) ............................. MU
Polypropylene ................................................................................ PP
PVDF (Dyflor) (for limit switches /Gl2 to /Gl4) .................................... PD
PTFE ............................................................................................. PF
PVC ............................................................................................... PC
Corundum ..................................................................................... KR
Float diameter 1,6 mm to 94 mm .............................................................................................. k
Flow liquid ................................................................................................................................... L
mark factor 1 (water) .................................................................................................................... 3
factor 0,63 (water) ............................................................................................................... 2
Float insertion without magnet.......................................................................................................................................... N
with magnet (for limit switches /GM 1 and /GM 2) .................................................................................... M2)
2)
For optional limit switch /GM1 to /GM2 3)
Option /MM is indicated in case no mm division is desired.
4)
For optional limit switch /GI1 to /GI4 *) The indicated pressure drop may deviate depending on the flowmeter used.
Other metering tube - float combinations with other float materials and a variety of measuring ranges are available on request.
GS 1R1B6-E-H
5
Description
Meterering tube length 300 mm ................... L
(type) 300 mm .................... G
Metering tube diameter 10 mm to 95 mm ................... k
Metering tube cone see flow table ............................................. kk
Metering tube Medium- scale on metering tube with mm division2 ........................ G
scale connection scale with mm division (recommended) ......... A
metering tube with mm division only ................................ N
Float 1.4571 ........................................................................................... SS
material Titanium ......................................................................................... TT
Mumetal (for limit switches /Gl1; /Gl2 and /Gl4) ............................. MU
Polypropylene ................................................................................ PP
PVDF (Dyflor) (for limit switches /Gl2 to /Gl4) ................................. PD
Aluminium ...................................................................................... AL
PVC ............................................................................................... PC
Corundum....................................................................................... KR
Float diameter 1,6 mm to 94 mm ................................................................................................... k
Flow air (gas) ................................................................................................................................. G
mark factor 10 (air) ........................................................................................................................ 5
factor 25 (air) ........................................................................................................................ 7
Float insertion without magnet ......................................................................................................................................... N
with magnet (for limit switches /GM 1 and /GM 2) .................................................................................... M1)
1)
For optional limit switches /GM1 to /GM2 3)
For optional limit switch /GI1 to /GI4
2)
Option /MM is indicated in case no mm division is desired. *) The indicated pressure drop may deviate depending on the flowmeter
used.
Other metering tube - float combinations with other float materials with a variety of measuring ranges are available on request.
GS 1R1B6-E-H
6
OPTIONS
Options Suffix code Description
Mark /B1 Stainless steel tag plate
/BK Customer-specified notes (please specify)
Flanges /F2 Loose flange DN 25 for nominal size 15 only
/F4 loose flange DN 40 for nominal size 25 only
/F5 Loose flange DN 50 for nominal size 40 only
/F6 Loose flange DN 65 for nominal size 50 only
Limit Contact Function Application for floats
switch /GI11) bistable inductive ring initiator -MU A _ N
/GI21) bistable inductive ring initiator -PD B _ N and -MU B _ N
/GI31) bistable inductive ring initiator -PD C _ N
/GI41) bistable inductive ring initiator -MU C _ N; -MU D _ N and -PD D _ N
/GM1 MlN contact mag. switch contact for floats with magnet only
/GM2 MAX contact mag. switch contact
In case of two limit switches the option for each switch can be indicated.
Metering tube /MM No mm scale (without calculation table)
suffix code /MV Viton gasket (for temperatures > 100 °C < 130 °C)
1)
No connection scale is available for options /Gl1 to /Gl4 (Code A).
Select the desired measuring range from the appropriate flow table. Note the required float material for limit switches resp. the insertion
(last column) and determine the suffix code for the metering tube - float combination.
After the code for metering tube - length - diameter, to be found in the model code, is determined, and the selection “with valve” or “without
valve” is made, the model code can be completed.
GS 1R1B6-E-H
7
DIMENSIONS
g DN K D
500 360
WEIGHT
DN D K g l Ind. m i Weight
15 95 65 45 14 4 100 88 6 kg
25 115 85 68 14 4 125 102 9,5 kg
40 150 110 88 18 4 175 145 14,5 kg
50 165 125 102 18 4 175 145 15 kg
GS 1R1B6-E-H
GERMANY AUSTRALIA UNITED STATES OF AMERICA
YOKOGAWA Yokogawa Deutschland GmbH
Berliner Strasse 101-103
D-40880 RATINGEN
Yokogawa Australia Pty Ltd.
Private mail bag 24
Centre Court D3
Yokogawa Industrial Automation
4 Dart Road
NEWNAN, GA 30265-1040
Tel. +49-2102-4983 0 25-27 Paul Street North Tel. +1-770-254 0400
AUSTRIA Fax +49-2102-4983 22 NORTH RYDE, N.S.W. 2113 Fax +1-770-251 6427
EUROPEAN HEADQUARTERS Tel. +61-2-805 0699
Yokogawa Europe B.V. Yokogawa Austria Ges.m.b.H. ISO 9001
Franzensbrückenstrasse 26 ITALY Fax +61-2-888 1844
Vanadiumweg 11, Yokogawa Italia S.r.l.
3812 PX AMERSFOORT A-1021 WIEN
Tel. +43-1-216 50 43 Vicolo D. Pantaleoni, 4 SINGAPORE
The Netherlands 20161 MILANO Yokogawa Engineering Asia Pte. Ltd.
Tel. +31-33-4641 611 Fax +43-1-216 50 43 33
Tel. +39-2-66 24 11 11, Tampines Street 92
Fax +31-33-4641 610 Fax +39-2-645 57 02 SINGAPORE, 528872
BELGIUM CERTIFICATED
E-mail: info@yokogawa.nl Tel. +65-783 9537 FIRM
Yokogawa Belgium N.V./S.A.
Minervastraat 16 SPAIN Fax +65-786 2606
THE NETHERLANDS Yokogawa España S.A.
Yokogawa Nederland B.V. 1930 ZAVENTEM
Tel. +32-2-719 55 11 C/Francisco Remiro, N°2, Edif. H Manufactured by:
Computerweg 1, 28028 MADRID GERMANY
3606 AV MAARSSEN Fax +32-2-725 34 99 CENTRAL/EAST REGION
Tel. +34-1-724 20 80 Rota Yokogawa GmbH & Co. KG
Tel. +31-346-59 12 11 Fax +34-1-355 31 40 Rheinstrasse 8 Via Yokogawa Austria: Czechia,
Fax +31-346-56 61 96 FRANCE Slovakia, Hungary, Poland,
Yokogawa Contrôle Bailey S.A. D-79664 WEHR
UNITED KINGDOM Tel. +49-7761-567 0 Croatia, Slovenia, Jugoslavia,
Vélizy Valley Bulgaria, Romania, Macedonia,
18-20 Rue Grange Dame Rose Yokogawa United Kingdom Ltd. Fax +49-7761-567 126
Stuart Road, Manor Park, Bosnia & Herzegovina
78140 VELIZY VILLACOUBLAY
Tel. +33-1-39 26 10 00 RUNCORN SOUTH AFRICA
Cheshire WA7 1TR Yokogawa South Africa (Pty) ltd. Distributors in:
Fax +33-1-39 26 10 30 Denmark, Finland, Greece,
Tel. +44-1-928 597100 67 Port Road, Robertsham
Fax +44-1-928 597101 Southdale 2135, JOHANNESBURG Norway, Portugal, Russian
Tel. +27-11-680-5420 Federation, Sweden,
Fax +27-11-680-2922 Switzerland and Turkey.
Block 03,01-98