Sie sind auf Seite 1von 1

ADAM-4060 4-ch Relay Output Module

ADAM-4068 8-ch Relay Output Module with Modbus

ADAM-4069 8-ch Power Relay Output Module with Modbus

ADAM-4060 RoHS
COMPLIANT
2002/95/EC
ADAM-4068 RoHS
COMPLIANT
2002/95/EC
ADAM-4069 RoHS
COMPLIANT
2002/95/EC

Specifications Specifications Specifications


General General General
ƒƒ Connectors 2 x plug-in terminal blocks ƒƒ Connectors 2 x plug-in terminal blocks ƒƒ Connectors 2 x plug-in terminal blocks
(#14 ~ 22 AWG) (#14 ~ 28 AWG) (#14 ~ 28 AWG)
ƒƒ Power Consumption 0.8 W @ 24 VDC ƒƒ Power Consumption 0.6 W @ 24 VDC ƒƒ Power Consumption 2.2 W @ 24 VDC
ƒƒ Watchdog Timer System (1.6 second) ƒƒ Watchdog Timer System (1.6 second) & ƒƒ Watchdog Timer System (1.6 second) &
ƒƒ Supported Protocols ASCII command Communication Communication
ƒƒ Supported Protocols ASCII command and ƒƒ Supported Protocols ASCII command and
Relay Output Modbus/RTU Modbus/RTU
ƒƒ Breakdown Voltage 500 VAC (50/60 Hz) Relay Output
ƒƒ Channels 2 x Form A Relay Output
ƒƒ Breakdown Voltage 500 VAC (50/60 Hz)
2 x Form C ƒƒ Breakdown Voltage 1,000 VAC (50/60 Hz)
ƒƒ Channels 4 x Form A
ƒƒ Contact Rating 0.6 A @ 125 VAC ƒƒ Channels 4 x Form A
4 x Form C
(Resistive) 0.3 A @ 250 VAC 4 x Form C
ƒƒ Contact Rating 0.5 A @ 120 VAC
2 A @ 30 VDC (Resistive) 0.25 A @ 240 VAC ƒƒ Contact Rating 5 A @ 250 VAC
0.6 A @ 110 VDC 1 A @ 30 VDC (Resistive) 5 A @ 30 VDC
ƒƒ Initial Insulation 1 G Ω min. at 500 VDC 0.3 A @ 110 VDC ƒƒ Initial Insulation 1 GΩ min. at 500 VDC
Resistance ƒƒ Initial Insulation 1 GΩ min. at 500 VDC Resistance
ƒƒ Relay off Time 2 ms Resistance ƒƒ Relay off Time 5.6 ms
(Typical) ƒƒ Relay off Time 4 ms (Typical)
ƒƒ Relay on Time 3 ms (Typical) ƒƒ Relay on Time 5 ms
(Typical) ƒƒ Relay on Time 3 ms (Typical)
ƒƒ Maximum Operating Speed (Typical) ƒƒ Maximum Operating Speed
20 operations/min (at related load) ƒƒ Maximum Operating Speed 6 operations/min (at related load)
50 operations/min (at related load)

Common Specifications Environment Ordering Information


ƒƒ Operating Humidity 5 ~ 95% RH
ƒƒ ADAM-4060-DE 4-ch Relay Output Module
General ƒƒ Operating -10 ~ 70°C (14 ~ 158°F) ƒƒ ADAM-4068-BE 8-ch Relay Output
Temperature Module with Modbus
ƒƒ Power Input Unregulated 10 ~ 30 VDC
ƒƒ Storage Temperature -25 ~ 85°C (-13 ~ 185°F) ƒƒ ADAM-4069-AE 8-ch Power Relay Output
Module with Modbus

Dimensions Unit: mm
60.00 28
25.00
6.5

70.00
56.00
56.00
120
122
142
112.00

46.00
25.00

2-SCREW
44.00

M3
56.00
Rear View M3
7.50

.50

Top View Din-Rail Mounting View


R2

R35.00
14.00
10.00

.0
Ø8
30.00 28
Front View Side View Panel Mounting View

Online Download www.advantech.com/products


All product specifications are subject to change without notice Last updated : 27-Jul-2016