Single GPO

Double GPO @
300mm unless
Powerpoint location specified
PL1
FL2 FL2 FL2 FL2 FL2 FL2 FL2 FL2 to be coordinated
Weather Proof GPO

11
27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

10

1
UP
UP with location of TV
PL1 PL1 PL1

6
5
4
3
2
1
PL1 @ 300mm C Wall Light
PL1 PL1 @ 300mm D WL8
PL1
Pendant Light
FL2 FL2 FL2 FL2 FL2 DL3 PEN1 PEN1 PEN1 DL3 DL3 DL3 DL5
LIVING
BALCONY Under Cupboard LED DL
PL1 DINING
PL1 LED Down Light
Timber @700mm in @700mm D/W 600mm minimum distance
decking black finish with between the tip of the Strip LED lighting
USB ports blade and the dowlights
DL3 DL3 DL3 DL3 DL5
PL1 @ 300mm Plant Lighting
PL1
UP 5
NEW POOL @1600mm SA WL8
DL10 DL10 DL10FRIDGE
DL10 LED strip to LED strip to Ceiling line Infloor Lights
top of truss top of truss SUN ROOM/STUDY
@1400mm
base base Exhaust Fan
DL3 DL3 DL3 DL2
M/W
PL1 KITCHEN @1000mm DL9 DL9 DL9 DL9 4 DL9
PL1 @ 300mm 15
LED strip to AC AC Control Panel
Power to F 14
top of truss
LED strip to LED strip to LED strip to
LED1 FL2 FL2 FL2 FL2 FL2 LED1 13
top of truss top of truss top of truss C
pool to be base Cable TV Access

6
5
4
3
2
1
12
base base base
confirmed GAS OUTLET FOR BBQ 11 DL9 DL9 DL9 DL9 DL9
DL2
DL3 Telephone Outlet
Timber with HEIGHT TBC
PANTRY UP UP
PL1 4
decking contractor PL1 PL1 PL1 PL1 WL10 WC Gas Outlet

10

17
16
15
14
13
12

10
11
9

8
7
6
5
4
3
2
1

9
8
7
6
5
4
3
2
1
@ 1000mm
D Data
@1600mm @ 300mm LED2 continue down to
Electrical - First Floor Plan FRIDGE LED2
30 Smoke Alarm
01 POWER TO OVEN @ 700mm +
1:100 POWER TO RANGE
HOOD @2000mm Handrail

LIST OF AMENDMENTS
1 DL1 to continue upstairs 22/06/18
LED strip
2 DL1 conected to WIR light switch 22/06/18
light 3 Switch to be relocated 22/06/18
4 LED strip lights to be connected to study's switch 22/06/18
HANDRAIL - LED DETAIL 5 DL3 to be connected to switch 22/06/18
04
1:2

FL2 FL2
UP
WL9 WL9 WL9 WL8 WL8 WL8 WL8
6
5
4
3
2
1

@ 300mm @ 300mm @ 300mm @ 300mm @ 300mm CD WL6


FL1 @ 300mm @ 300mm C @ 300mm PL1 @ 300mm
600mm 600mm 600mm 600mm minimum distance
DL3 minimum DL3 DL3 minimum DL3 DL3 minimum DL3 between the tip of the blade
DL3 and the dowlight DL3
DL4
BED 4 BED 3 BED 2
600mm minimum distance 600mm
between the tip of the blade minimum
FL1 and the dowlight PL1 GARAGE
DL3 DL3 DL3 DL3 DL3 DL3 BED 1
600mm minimum
distance between the tip DL3 DL3
of the blade and the
dowlight @ 300mm @ 300mm
Linen
3 DL4 DL4
DL1 DL1 PL1
FL1 DL1 DL1
W/R DL6
2 E/S
SA (Tiles) WL7
UP @ 300mm
@300mm 1 WL6
BATH W/C L'DRY 2

(Tiles) (Tiles) (Tiles)


3 DL1 and LED2
continue up 1 ENTRY
WL9 UP UP PL1 UP
FL1 LED2 continue up to DL2 LED2 DL1 SA DL5
LED2 WL5 WL5 WL5
17
16
15
14
13
12

10

17
16
15
14
13
12

10
11

11
9
8
7
6
5
4
3
2
1

9
8
7
6
5
4
3
2
1
continue down to continue down to
DL1 LED2
Electrical - Ground Floor Plan Electrical - Basement Plan
02 03
1:100 1:100
Legend: TC - Timber cladding Project Drawing content Drawing No.
SC - Stone cladding Level 1, 722 Bourke St, Redfern NSW 2016
Demolition line DP - Down pipe as per s/w details - Basement Plan,
Electrical Layout
www.archebiosis.com
P 02 8399 2334
Design mendments
Electrical - Ground Floor SK 700
Boundary line MR - Metal roof E archebiosis@archebiosis.com
14 Close Street, Plan, Electrical - First Floor
No. 16 Proposed AW - Awnings Archebiosis Architects is the owner of the copyright of these
South Coogee Plan
building line GD - Glazing door drawings. No reproduction or use of them must be done Project Status Scale Date Issue No.
without prior permission and written consent. Copyright 2018 CD 1:100 @ A3 6
GSPublisherVersion 0.19.100.90
W - Window 22/06/2018

Das könnte Ihnen auch gefallen