Beruflich Dokumente
Kultur Dokumente
MMCT 5113
“ASSIGNMENT 1”
PREPARED FOR:
With the consideration of the variation of the temperature with time constraints as well
as position in one and multidimensional systems, transient heat transfer can be describe as the
lumped body in which the temperature of the body varies with time but remains uniform
throughout at any time.
Interior temperatures of some bodies remain essentially uniform at all times during a
heat transfer process. The temperature of such bodies are only a function of time, T = T(t).
The heat transfer analysis based on this idealization is called lumped system analysis.
Consider a body of arbitrary shape of mass m, volume V, surface area A, density ρ and
specific heat Cp initially at a uniform temperature Ti. The lumped system analysis can be
simplified as figure below.
At time t = 0, the body is placed into a medium at temperature T∞ (T∞ >Ti) with a heat
transfer coefficient h. An energy balance of the solid for a time interval dt can be expressed
as:
heat transfer into the body during dt = the increase in the energy of the body during dt
h A (T∞ ‐ T) dt = m Cp dT
Using above equation, we can determine the temperature T(t) of a body at time t, or
alternatively, the time t required for the temperature to reach a specified value T(t). Note that
the temperature of a body approaches the ambient temperature T∞ exponentially. A large
value of b indicates that the body will approach the environment temperature in a short time.
b is proportional to the surface area, but inversely proportional to the mass and the specific
heat of the body. The total amount of heat transfer between a body and its surroundings over a
time interval is:
Q = m Cp [T(t) – Ti]
From my identification, one of the devices that involve heat transfer system is the heat
pipe inside the laptop. Basically, heat pipe is the device which looks like a copper pipe that
connected between the Central Processing Unit (CPU) and Graphic Processing Unit (GPU) to
the internal flow rate fans inside your laptop as shown in figure 1. The CPU and GPU is
known as the laptop brain which used to process all data input from the user. CPU and GPU
also is the main source of heat in the system that makes the user feel the heat from the
outsides which have to be cooling down in order to avoid the system from overheating.
Overheating laptop can gives many negative impacts in term of slowing down the
performance of the laptop (lagging and hang), loss of data and even burn out the other
component inside including the motherboard. That is why cooling systems are very important
in other to provide the better performance for the user. Heat pipe is one of the commonly use
cooling system in the laptop. Heat pipe is basically is the heat transfer device that combines
the principles of both thermal conductivity and phase transition to efficiently manage the
transfer of heat between two solid interfaces. [13]
Heat Pipe and the Heat Transfer Phenomena.
Not only limited to the Laptop cooling system, heat pipe is widely used as the cooling
system in many areas which includes solar energy systems, heat recovery systems, air
conditioning systems, cooling of energy storage and electronic equipment, industrial
applications and space apparatus. Heat pipes can be designed and constructed with various
cross-sectional areas and geometries ranging from the small design for electronic device to the
large design for industrial application.
In the laptop application, the heat pipe working principle can be describes base on
figure 2 below. The heat pipe is basically connected from the CPU as shown in condition 1 to
internal fan in condition 6. In 1, as the CPU produce heat, the heat is being absorb by the
working fluid and cause them to evaporate to vapour, the vapour then migrates along the
cavity (2), to the lower temperature end which toward the internal fan.
Figure 2: the heat pipe thermal cycle
In 3, as the fan blow the air through the end of the heat pipe, it causes the heat to be
removes from the vapour and make it condense back to became fluid. The fluid is then
absorbed by the wick at the wick area as shown in figure 3. The fluid is the flow back to the
high temperature area due to the capillary pressure.
From the basic concept of the heat pipe which transport liquid through the capillary
wick and vaporized the fluid in vapour area. However, if the pipe are too long, the capillary
wick incur a large flow pressure drop. Furthermore, because liquid and vapour flow in
opposite directions, vapour can entrain liquid at high power rates and limit the operation of
the device. Therefore, there are many developments which involve in the design of the heat
pipe in order to overcome those problems. However, each of the development was tied to the
field of the application itself. Loop heat pipe (LHP) and Capillary pumped loop (CPL) as
example, were developed for large application which is for spacecraft where the design have
the capability to overcome the problem of unreliable application of long distance application
and have the ability to operate against gravity.
Both the CPL and LHP consist of an evaporator capillary pump for heat acquisition, a
reservoir for storing the working fluid, a condenser for condensation of vapour from the
reservoir, and vapour and liquid transport lines. Basic operational principles of a CPL and
LHP are very similar. CPLs are limited by their inability to tolerate vapour in the pump core
and have tedious and time-consuming start-up procedures. LHPs are capable of limited
system temperature regulation, but this feature is usually difficult to achieve [4]. Therefore,
the Innovation in terms of the loop heat pipe evaporator has been the major focus to improve
system efficiency and reduce the diameter of the evaporation section. Figure 4 show the
schematic diagram of the CLP system.
Another recent technology which involve in the development of the heat pipe are the
Hybrid heat pipe. The hybrid heat pipe is used for advanced nuclear power plant as the
passive heat transfer device. As shown in figure 5, the hybrid heat pipe combines the
functions of a heat pipe and a control rod to simultaneously remove the decay heat generated
from the core and shutdown the reactor under accident conditions. Thus, the hybrid heat pipe
contains a neutron absorber in the evaporator section, which corresponds to the core of the
reactor pressure vessel. The presence of the neutron absorber material leads to differences in
the heated diameter and hydraulic diameter of the heat pipe. The cross-sectional areas of the
vapour paths through the evaporator, adiabatic, and condenser sections are also different. The
hybrid heat pipe must operate in a high-temperature, high-pressure environment to remove the
decay heat. In other words, the operating pressure must be higher than those of the
commercially available thermosyphons. [8]
[1] Trijo Tharayil, Lazarus Godson Asirvatham , Michel Jerome Dau, Somchai
Wongwises (2016) Entropy generation analysis of a miniature loop heat pipe with graphene–
water nanofluid: Thermodynamics model and experimental study. International Journal of
Heat and Mass Transfer 106 (2017) 407–421.
[2] W. Wu, ‘Micro-loop heat pipe’, United States Patent Application No. 20030192669,
October 16, 2003.
[3] Jiang Cheng, Gang Wang, Yong Zhang, Pihui Pi, Shouping Xu (2016) Enhancement of
capillary and thermal performance of grooved copper heat pipe by gradient wettability
surface. International Journal of Heat and Mass Transfer 104 (2017) 586–591
[4] T. T. Hoang, ‘Loop heat pipe method and apparatus’, United States Patent No
6810946, November 2, 2004.
[5] Niro Nagaia, Akikazu Iwamotoa, Toyoji Onishib, Hideo Shingub (2011) Advances
And Opportunities In Bubble-Actuated Circulating Heat Pipe (BACH). Global Digital Central
ISSN: 2155-658X.
[6] Masataka Mochizuki, Thang Nguyen, Koichi Mashiko, Yuji Saito, Tien Nguyen and
Vijit Wuttijumnong (2011) A Review Of Heat Pipe Application Including New Opportunities.
Global Digital Central ISSN: 2155-658X.
[7] Amir Faghri (2014) Heat Pipes: Review, Opportunities And Challenges. Global Digital
Central ISSN: 2155-658X.
[8] Kyung Mo Kim, In Cheol Bang (2014) Heat transfer characteristics and operation
limit of pressurized hybrid heat pipe for small modular reactors. Applied Thermal Engineering
112 (2017) 560–571
[9] Vipul M. Patel, Gaurav, Hemantkumar B. Mehta (2016) Influence of working fluids on
startup mechanism and thermal performance of a closed loop pulsating heat pipe. Applied
Thermal Engineering 110 (2017) 1568–1577
[10] M. Nishikawara , H. Nagano (2016) Optimization of wick shape in a loop heat pipe for
high heat transfer. International Journal of Heat and Mass Transfer 104 (2017) 1083–1089
[11] Jiang Cheng, Gang Wang, Yong Zhang, Pihui Pi, Shouping Xu (2016) Enhancement of
capillary and thermal performance of grooved copper heat pipe by gradient wettability
surface. International Journal of Heat and Mass Transfer 107 (2017) 586–591
[12] Yaxuan Xiong, Li Bo, Meng Qiang, Yuting Wub, Xingxing Zhang, Peng Xu,
Chongfang Mab (2016) A characteristic study on the start-up performance of molten-salt heat
pipes: Experimental investigation. Experimental Thermal and Fluid Science 82 (2017) 433–
438