Sie sind auf Seite 1von 8

ID Counter NodeB/RNC Description

50332683 VS.IPDlMaxUsed.1 NodeB

50332684 VS.IPDlAvgUsed.1 NodeB

67194639 VS.IPPATH.PING.MaxJITTER NodeB T6555:Maximum IP Path Ping Delay


variation

50332741 VS.IUB.FlowCtrol.DL.DelayVara.LgcPort1.Max NodeB When the DYNAMIC_BW_SHAPING


algorithm is enabled, the NodeB
calculates the DL jitter per five
seconds. When other algorithms are
used, the NodeB reports 0 as the
statistics value.
VS.IUB.FlowCtrol.DL.DelayVara.LgcPo
rt.Max is the collected maximum value
of DL jitter.

50332743 VS.IUB.FlowCtrol.DL.DelayVara.LgcPort1.Avg NodeB When the DYNAMIC_BW_SHAPING


algorithm is enabled, the NodeB
calculates the DL jitter per five
seconds. When other algorithms are
used, the NodeB reports 0 as the
statistics value. All collected values of
DL jitter in a statistics are accumulated
and recorded as A, and the number of
calculation times is recorded as B.
Then,
VS.IUB.FlowCtrol.DL.DelayVara.LgcPo
rt.Avg = A/B.

50332738 VS.IUB.FlowCtrol.UL.DelayVara.LgcPort1.Max NodeB The NodeB calculates the UL jitter per


five seconds.
VS.IUB.FlowCtrol.UL.DelayVara.LgcPo
rt.Max is the collected maximum value
of UL jitter.

50332740 VS.IUB.FlowCtrol.UL.DelayVara.LgcPort1.Avg NodeB The NodeB calculates the UL jitter per


five seconds. All collected values of UL
jitter in a statistics period are
accumulated and recorded as A, and
the number of calculation times is
recorded as B. Then,
VS.IUB.FlowCtrol.UL.DelayVara.LgcPo
rt.Avg = A/B.

50332736 VS.IUB.FlowCtrol.UL.DropNum.LgcPort1 NodeB HSUPA Iub Flow Control in Case of Iub


Congestion

50332737 VS.IUB.FlowCtrol.DL.DropNum.LgcPort1 NodeB HSDPA Flow Control


50332744 VS.IUB.FlowCtrol.UL.CongTime.LgcPort1 NodeB HSUPA Iub Flow Control in Case of Iub
Congestion

50332745 VS.IUB.FlowCtrol.DL.CongTime.LgcPort1 NodeB

67203853 VS.NodeB.UnavailTime NodeB Duration of NodeB Unavailability

67192144 VS.SCTP.RETX.PKGNUM RNC T6007:Number of Packets Resent on


the SCTP Link

67191616 VS.SCTP.RX.MAXPKGNUM RNC T6008:Maximum Number of IP Packets


Received on the SCTP Link

67191617 VS.SCTP.TX.MAXPKGNUM RNC T6009:Maximum Number of IP Packets


Transmitted on the SCTP Link

67184352 VS.SCTP.RX.ERRPKGNUM RNC T6010:Number of Error Packets


Received on SCTP Link
67191618 VS.SCTP.SERVICE.INTERVAL RNC Service Duration of the SCTP Link

67191619 VS.SCTP.CONGESTION.INTERVAL RNC Congestion Duration of the SCTP Link

67194653 OS.M3UA.Lnk.Cong.Dur RNC T6163:Duration of M3UA Link


Congestion

73394059 VS.PSLoad.MaxThruput.RNC RNC Maximum Total Throughout of UL and


DL PS Services for RNC

67192086 VS.CSLoad.MaxErlang.Equiv.RNC RNC Maximum equivalent CS


Conversational Erlang for RNC
67194743 VS.DPU.CPULOAD.MAX RNC HR9760:Maximum CPU Usage of the
DPU

67194447 VS.GCU.CPULOAD.MAX RNC HR9750:Maximum CPU Usage of the


GCU

67194751 VS.SCU.CPULOAD.MAX RNC HR9730:Maximum CPU Usage of the


SCU

73390062 VS.XPU.CPULOAD.MAX RNC HR9780:Maximum CPU Usage of the


XPU
Detailed Description Measurement point
The NodeB takes statistics about the maximum used DL bandwidth
on an IP physical port during a measurement period. The NodeB
measures the used DL bandwidth on the physical port every five
seconds over 15 minutes and then obtains the maximum value. The
NodeB can take statistics on this counters for a maximum of IP
physical ports.

The NodeB takes statistics about the maximum used DL bandwidth


on an IP physical port during a measurement period. The NodeB
measures the used DL bandwidth on the physical port every five
seconds over 15 minutes and then obtains the maximum value. The
NodeB can take statistics on this counters for a maximum of IP
physical ports.

This counter provides the maximum ping delay variation of an IP The system automatically samples the
path in the specified measurement period. It takes effect only when IP path ping delay every 5 minutes. In
the IPPATH PING function is enabled the specified measurement period, the
max ping delay is set to be this
counter

For the preceding counters, the


NodeB takes statistics in each
scheduling period.

For the preceding counters, the


NodeB takes statistics in each
scheduling period.

For the preceding counters, the


NodeB takes statistics in each
scheduling period.

For the preceding counters, the


NodeB takes statistics in each
scheduling period.
The NodeB determines whether the following requirement is met:
VS.IUB.FlowCtrol.UL.AdjBW.LgcPort.Avg*0.8 < Actual physical layer
flow of the UL logic port. If the preceding requirement is met, the UL
congestion duration is increased by one second. If the preceding
requirement is not met, the UL congestion duration does not change.
The NodeB collects the UL congestion duration per five seconds. All
collected values in a statistics period are accumulated. The NodeB
reports the traffic statistics of logic ports that are configured with
PATH. The NodeB can take the traffic statistics on these counters for
a maximum of two logic ports and it preferentially reports the
statistics for IP transmission. If only one logic port is configured, the
traffic statistics of only one logic port is reported.

When the DYNAMIC_BW_SHAPING algorithm is enabled in


complete sharing mode of configured bandwidth, the NodeB
determines whether the following requirement is met:
VS.IUB.FlowCtrol.DL.AdjBW.LgcPort.Avg*0.8 < HSDPA flow of the
DL logic port. If the preceding requirement is met, the DL congestion
duration is increased by one second. If the preceding requirement is
not met, the DL congestion duration does not change. The NodeB
calculates the DL congestion duration per five seconds. When other
algorithms are used, the NodeB reports 0 as the calculation value. All
collected values in a statistics period are accumulated. The NodeB
reports the traffic statistics of logic ports that are configured with
PATH. The NodeB can take the traffic statistics on these counters for
a maximum of two logic ports and it preferentially reports the
statistics for IP transmission. If only one logic port is configured, the
traffic statistics of only one logic port is reported.

This measurement item provides the unavailability time of a NodeB, The RNC measures this item based
that is, the out-of-service time of a NodeB. The NodeB is unavailable on the accumulated unavailability time
in the following conditions: (1) The NodeB fails; (2) All the cells are of the NodeB in a measurement
deactivated; (3) The RNC fails. Note: In the measurement period, the period.
RNC does not add the duration of carrier shutdown to the cell
unavailability time.

This counter provides the number of packets resent on the SCTP link In the measurement period, the
in the specified measurement period. counter is incremented by one when
the packet is resent on the SCTP link.

These counters provide the number of IP data packets received or


sent on the SCTP link in the specific measurement period.

These counters provide the number of IP data packets received or


sent on the SCTP link in the specific measurement period.

All the packets transferred on the SCTP links are assembled from In the measurement period, the
data blocks. Error packets may occur with respect to network counter is incremented by one when
performance or upper-layer application. This counter provides the the error packets are received on the
number of error packets received over SCTP links. SCTP link.
This counter provides the in-service duration of an SCTP link. This measurement is triggered when
the SCTP link changes from the
unavailable state to the available
state. The measurement is stopped
and the service duration is calculated
when the SCTP link returns to the
unavailable state. At the end of the
measurement period, the system
calculates all the service durations of
the SCTP link and restarts the
measurement.

This counter provides the congestion duration of the SCTP link. This measurement is triggered when
congestion occurs on the SCTP link.
The measurement is stopped and the
congestion duration is calculated when
the SCTP link changes from the
congestion state to non-congestion
state. At the end of the measurement
period, the system calculates all the
congestion durations of the SCTP link
and restarts the measurement.

In the measurement period, the


This counter provides the duration of M3UA link congestion. system takes samples from the status
of an M3UA link every five seconds. If
the MTP3 link is congested, this
counter is incremented by five.

This counter provides the maximum total throughput of uplink and The total throughput of uplink and
downlink PS services in the RNC. downlink PS services in the RNC is
sampled periodically. At the end of the
measurement period, the maximum
throughput is obtained. The RLC
header is not included and the
retransmission data is included in the
counter.

This measurement item provides the maximum equivalent Erlang The RNC periodically takes a sample
values of all the services in the CS domain within the RNC. from the equivalent Erlang values of
all the services in the CS domain. At
the end of the period, the RNC
calculates the maximum equivalent
Erlang of all the services in the CS
domain within the RNC, include the
equivalent Erlang of all radio links of
Soft Handover.Each time a CS domain
service is established, the RNC
converts its rate to the equivalent
Erlang, and then increases the
equivalent Erlang of the CS domain in
the current RNC. Each time a CS
domain service is released, the RNC
decreases the equivalent Erlang of the
CS domain in the current RNC.
This counter provides the maximum CPU usage of the DPU in a The CPU usage of the DPU is
measurement period. It indicates the load and operating sampled every second in the
performance of the CPU on the DPU in the measurement period. measurement period. Then, the
maximum usage is taken as the value
of this counter.

This counter provides the maximum CPU usage of the GCU in a The CPU usage of the GCU is
measurement period. It indicates the load and operating sampled every second in the
performance of the CPU on the GCU in the measurement period. measurement period. Then, the
maximum usage is taken as the value
of this counter.

This counter provides the maximum CPU usage of the SCU in a The CPU usage of the SCU is
measurement period. It indicates the load and operating sampled every second in the
performance of the CPU on the SCU in the measurement period. measurement period. Then, the
maximum usage is taken as the value
of this counter.

This counter provides the maximum CPU usage of the XPU in a The CPU usage of the XPU is
measurement period. It indicates the operating load and sampled every second in the
performance of the CPU on the XPU in the measurement period. measurement period. Then, the
maximum usage is taken as the value
of this counter.

Das könnte Ihnen auch gefallen