AlarmCode 1/8

External extended device fault

AlarmAttribute

Alarm Code:198098468 External extended device fault

Alarm Severity:Minor

Alarm Reason

1. The external extended device is faulty.

2. The external extended device is configured with incorrect parameters.

3. The external extended device has a faulty connection.

System Influence

I. Impact on the equipment:

None.

II. Impact on the services:

Some of the services on this board may be interrupted or the service


quality may be affected.

Handling Suggestions

Perform the following operations according to the additional alarm


information in the alarm details:

Other hardware errors, other software errors, RAM error, UART error,
TMA critical alarm level, TMA minor alarm level, hardware fault, software
fault, EEPROM error, FLASH erase error, FLASH error, or external LNA fault:

1. Select Dynamic Management -> Dynamic Command -> SDR -> AISG
Device, and reset the AISG device according to the antenna number/rack
number/device type in the additional alarm information in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.


AlarmCode 2/8

Yes -> End.

No -> Step 2.

2. Replace the device according to the antenna number/rack


number/device type in the additional alarm information in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Contact the customer service center.

Communication link disconnected, or the link between the RRU and


the external LNA disconnected:

1. Verify that the cable of the equipment is connected properly.

a. Check whether the communication cable between the external


extended device and the base station system is connected properly.

Yes -> Step 2.

No -> Substep b.

b. Re-connect the cable.

c. Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Step 2.

2. Reset the board according to the rack number/shelf number/slot


number in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Step 3.

3. Replace the device according to the antenna number/rack


number/device type in the additional alarm information in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.


AlarmCode 3/8

Yes -> End.

No -> Contact the customer service center.

Device address conflict:

1. Scan and add a new device in the AISG device management.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Contact the customer service center.

Failure in gain configuration:

1. Re-configure the uplink gain of the device.

a. Select Configuration Management -> Managed Element -> Device ->


BTS Auxiliary Peripheral Device -> Antenna Service -> TMS Device, and
configure the uplink gain to the value within the scope of gains supported by
the device.

b. Synchronize the configurations to the corresponding NE.

c. Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Step 2.

2. Select Dynamic Management -> Dynamic Command -> SDR -> AISG
Device, and reset the AISG device according to the antenna number/rack
number/device type in the additional alarm information in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Contact the customer service center.

Electrical machine faults, or the electrical machine unable to be


adjusted:
AlarmCode 4/8

Electrical machine faults, or the electrical machine unable to be


adjusted:

1. Select Dynamic Management -> Dynamic Command -> SDR -> AISG
Device, and perform RET calibration according to the antenna number/rack
number/device type in the additional alarm information in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Step 2.

2. Re-install the electrical machine, and re-perform RET calibration.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Step 3.

3. Replace the device according to the antenna number/rack


number/device type in the additional alarm information in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Contact the customer service center.

Failure in data storage, no configuration data, no response from the


electrical machine to the adjustment command, unable to perform
calibration, or incorrect location value responded by the electrical machine:

1. Select Dynamic Management -> Dynamic Command -> SDR -> AISG
Device, and perform configuration data transmission and then RET
calibration according to the antenna number/rack number/device type in the
additional alarm information in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Step 2.

2. Re-install the electrical machine, and re-perform RET calibration.

Wait for 15 minutes, and check whether the alarm is cleared.


AlarmCode 5/8

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Step 3.

3. Replace the device according to the antenna number/rack


number/device type in the additional alarm information in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Contact the customer service center.

Working in bypass mode:

1. Select Dynamic Management -> Dynamic Command -> SDR -> AISG
Device, and configure the tower mounted amplifier to the normal mode
according to the antenna number/rack number/device type in the additional
alarm information in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Step 2.

2. Reset the device according to the antenna number/rack


number/device type in the additional alarm information in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Contact the customer service center.

Abnormal current on the NSBT port, or the overcurrent switch of the


AISG interface/NSBT port disconnected:

1. Verify the alarm threshold of the current is properly configured:

a. Select Configuration Management -> Managed Element -> Device ->


RRU -> PowerOutlet Set-> PowerOutlet, and check whether the
undercurrent/overcurrent alarm threshold percentages are configured as
AlarmCode 6/8

RRU -> PowerOutlet Set-> PowerOutlet, and check whether the


undercurrent/overcurrent alarm threshold percentages are configured as
planned.

Yes -> Step 2.

No -> Substep b.

b. Modify the alarm threshold percentages as planned.

c. Synchronize the configurations to the corresponding NE.

d. Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Step 2.

2. Verify that the cables of the antenna and feeder system are properly
connected.

a. Check whether the cables of the antenna and feeder system are
properly connected (For example, the connectors are not secured, or there
are short circuits).

Yes -> Step 3.

No -> Substep b.

b. Re-connect the cables.

c. Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Step 3.

3. Replace the device according to the antenna number/rack


number/device type in the additional alarm information in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Contact the customer service center.

The inconsistency of the RET antenna type, or the inconsistency of the


external LNA type:
AlarmCode 7/8

The inconsistency of the RET antenna type, or the inconsistency of the


external LNA type:

1. Verify that the type of the external extended device is set to be the
same as that of the actual device.

a. Select Configuration Management -> Managed Element -> Device ->


RRU -> AISG Device, and check whether the type of the device is set to be
the same as that of the actual device according to the antenna number/rack
number/device type in the additional alarm information in the alarm details.

Yes -> Step 2.

No -> Substep b.

b. Modify the device type to be the same as that of the actual device.

c. Synchronize the configurations to the corresponding NE.

d. Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Step 2.

2. Replace the device according to the antenna number/rack


number/device type in the additional alarm information in the alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Contact the customer service center.

Tilt of RET is faulty:

1. Select Dynamic Management -> Dynamic Command -> SDR -> AISG
Device, and perform RET calibration according to the antenna number/rack
number/device type/right tilt value in the additional alarm information in the
alarm details.

Wait for 15 minutes, and check whether the alarm is cleared.

Yes -> End.

No -> Contact the customer service center.


Revision Date:June 2008 .
AlarmCode 8/8

Revision Date:June 2008 .