Sky Air

Product catalogue 2017


for professionals

R-32
IS AN
INDUS
REVOL TRY
UTION
BE PA .
RT OF
IT.

Get ahead of the competition


Advantages
With this interactive PDF we want to ensure you quickly
find back the information you are looking for. Within this
catalogue or via direct links to our business portal.
Focus on your business, we are here to help you.

We need your feedback


Fill out 5 simple questions to help us improve this
catalogue. We ‘ve put these questions on an online
link, so we can easily process all surveys continuously.

TAKE THE ONLINE SURVEY »

i2
SKY AIR INTRO
INDOOR
UNITS
OUTDOOR
UNITS
Navigation

AIR CURTAINS
BIDDLE
Sidebar links
The different chapters in the
catalogue are shown at the
side. You will be taken directly

VENTILATION
to the index page of the with
a single click.

All page numbers clickable


Click any page number you see and you will go
directly to the page.

CONTROL
SYSTEMS
Always in control,
no matter where you are 8

& ACCESSORIES
OPTIONS

Links to technical documentation


On the pages with technical drawings you can
& PLATFORMS

click the button above to get access to all technical


TOOLS

drawings available for the product

VIEW ALL TECHNICAL DRAWINGS


ON MY.DAIKIN.EU
TECHNICAL
DRAWINGS

Click to go back
PREVIOUS

i3
The future is in
your hands
Define the future of A/C

Introducing the new Sky Air A-series with ultra-efficient


Bluevolution R32 technology, available in three
models: the world-class Alpha, Advance and Active.
The new Sky Air A-series delivers future-proofed, best-in-class
climate control for your business and customers.
Design flexibility. More compact. Quieter. With an extended operating range
in all climate conditions.
Help is at hand. Quicker and easier installation and usability, even for replacement
systems.
Daikin at the heart of the system. Reduced running costs and drastically lowered
environmental impact. All thanks to Daikin’s tried, tested and trusted technology.
Geared for comfort. Advanced remote control possibilities, geared to your customers’
individual needs.

Get ahead of the competition. Talk to Daikin about Sky Air today.
www.daikin.eu/skyairbluevolution

2
SKY AIR INTRO
INDOOR
UNITS
Table of contents

OUTDOOR
UNITS
AIR CURTAINS
BIDDLE
Discover the Sky Air A-series 4

7 reasons why Sky Air


is unique in the market 6

VENTILATION
A solution for every application 12

Indoor units 15

CONTROL
SYSTEMS
Outdoor units 89

& ACCESSORIES
OPTIONS
Biddle air curtains 110

Ventilation113
& PLATFORMS

Control Systems 127


TOOLS

Options & accessories 155


TECHNICAL
DRAWINGS

Tools and platforms 163

Technical Drawings 171


PREVIOUS

3
Discover
Sky Air A-series
on page 92

4
SKY AIR INTRO
Get ahead
of the competition

INDOOR
UNITS
Europe’s first light commercial system
using R-32 refrigerant

OUTDOOR
UNITS
›› R-32 Global Warming Potential (GWP) is 68% lower
than the industry standard R-410A
›› Highest efficiency (SEER up to 8.02) in the market
›› Does not require yearly refrigerant containment
checks, which reduces maintenance costs
›› 16% less refrigerant charge

AIR CURTAINS
BIDDLE
App Control
›› Control your device at anytime from anywhere
›› Intuitive

VENTILATION
›› Via smartphone, tablet or cloud

3-row heat exchanger


›› Unique 3-row heat exchanger to
Lighter and more compact units allow compact casing up to 14 kW

for easy installation.

CONTROL
SYSTEMS
Unique single fan range up to 14 kW

& ACCESSORIES
OPTIONS
Redesigned pivoting front plate
for easy access to vital system
components
& PLATFORMS
TOOLS

New 7-segment display


to do outdoor unit settings
TECHNICAL
DRAWINGS

and view operating conditions


PREVIOUS

5
ARGUE CARDS

Sky Air, the solution


for the light
commercial sector.

7 reasons why Sky Air is


unique in the market
1 Full Sky Air R-32 range
NEW delivering future-proofed,
best-in-class climate control
More details
on page 92
System Type Model Product name PG 71 100 125 140
6.8 kW 9.5 kW 12.1 kW 13.4 kW

RZAG-MV1 102

- Industry leading technology for commercial applications


--Dedicated solution for infrastructure cooling
--Variable Refrigerant Temperature
--Maximum piping length up to 85m
--Replacement technology RZAG-MY1 102
--Extended operation range down to -20°C in both heating and cooling
--Pair, twin, triple and double twin application

RZASG-MV1 103
Air Heat
cooled pump --Technology and comfort combined for commercial applications
--Very compact and easy to install outdoor units
--Maximum piping length up to 50m
--Replacement technology RZASG-MY1 103
--Operation range down to -15°C both cooling and in heating
--Pair, twin, triple and double twin application

AZAS-MV1 104

--Ideal solution for busy environments and small shops


--Very compact and easy to install outdoor units
--Maximum piping length up to 30m
--Replacement technology AZAS-MY1 104
--Easy-to-mount outdoor units: roof, terrace or wall
--Exclusively offered for pair applications

Full indoor line up available for R-32 and R-410A


(over 45 different models)

6
SKY AIR INTRO
2 High energy efficiency
›› Top seasonal efficiency
›› SEER up to 8.02 and A++ label in cooling and heating
›› Variable Refrigerant Temperature that automatically

INDOOR
UNITS
adapts the refrigerant temperature to the load
NEW ›› Round flow and concealed ceiling units with auto cleaning filter

3 Best comfort
›› Variable Refrigerant Temperature preventing cold draughts

OUTDOOR
UNITS
›› Low sound indoor and outdoor units
›› Presence and floor sensors direct the air flow away from persons, while
ensuring an even temperature distribution
NEW ›› Operation down to -20°C in heating and cooling operation presence sensor
floor sensor
›› Fresh air intake integrated in indoor unit

4 Top reliability

AIR CURTAINS
BIDDLE
›› For infrastructure cooling
›› unique boosted capacity indoor unit systems
›› duty rotation control
NEW ›› Refrigerant cooled PCB
›› New refrigerant passes keeping heat exchanger and drain holes
completely open at all times

VENTILATION
›› Most extensive testing before new units leave the factory
›› Widest support network and after sales service
›› All spare parts available in Europe bottom plate refrigerant pass

5 Market leading controls


NEW ›› Remote connectivity

CONTROL
SYSTEMS
›› Intuitive app control
›› Daikin Cloud Service offering online control, energy monitoring
and comparison of multiple sites Tabl
et

NEW ›› User-friendly wired remote controller with premium design BRC1H51


›› Intuitive touch button control
›› 3 color versions
›› Advanced settings can be easily done via your smartphone

& ACCESSORIES
›› Dedicated control solutions

OPTIONS
›› for retail applications
›› for infrastructure cooling BRC1H51W

6 Superior aesthetics
›› Fully flat cassette design unit that integrates fully flat into the ceiling
& PLATFORMS

›› Auto cleaning units ensure dirt-free ceilings with high efficiency filters for
TOOLS

regular and dust prone areas

7 Unique installation benefits


›› 4-way blow ceiling suspended cassette (FUA) for rooms without false ceiling.
TECHNICAL
DRAWINGS

›› Plug & play Daikin air handling unit with ERQ condensing units
›› Total solution for cooling, heating, air curtains and ventilation
›› Dedicated assymetric combinations for infrastructure cooling
NEW ›› Reliably replace Daikin and non-Daikin systems without the need for pipe cleaning
thanks to the new hepta filtration
›› Use up to 4 indoor units linked to one outdoor unit for long
or irregularly shaped rooms
PREVIOUS

7
Always in control,
no matter where you are

Online Controller All unified indoor units connectable

›› Simple control from your smartphone Connectable units overview:


›› Control your device at anytime from anywhere
›› For single shop control Ceiling mounted Wall mounted
›› 3rd party products and services integration via ›› FCAHG-G ›› FAA-A
IFTTT ›› FCAG-A
›› FFA-A Ceiling suspended
›› FHA-A
More details
Concealed ceiling ›› FUA-A
on page 130 ›› FDXM-F3
›› FBA-A Floor standing
›› FDA-A ›› FVA-A
›› ADEQ-C ›› FNA-A

If this, then that


›› IFTTT is a solution that connects compatible 3rd
party products and services (smart meters, lights,
thermostats, ...), so they work best for you.

BRP069A81

Intelligent Tablet Controller From one to ∞ sites

Table
t

LOCAL
CONTROL

›› User-friendly touch screen to centrally control your


A/C and alarms
›› Connects to the Daikin Cloud Service DAIKIN CLOUD
›› Built for multi-site control and monitoring SERVICE
›› Installers and technical managers can see alarms so
DCC601A51 they can provide remote assistance

More details
on page 140 Installer/
Customer technical manager

8
SKY AIR INTRO
Unique
auto cleaning technology

INDOOR
UNITS
OUTDOOR
UNITS
Reduce running costs Minimal time required for filter cleaning
›› Automatic filter cleaning ensures high efficiencies and low ›› The dust box can be emptied with a vacuum cleaner for fast
maintenance costs because the filter is always clean and easy cleaning

AIR CURTAINS
›› No more dirty ceilings

BIDDLE
Efficiency profile change for duct indoor unit during operation
100% Up to 20% Unique technology
Energy is saved
Gradual loss of thanks to
›› Unique and innovative filter technology inspired by
efficiency due automatic filter the Daikin auto cleaning cassette
to dirty filter cleaning
Improved indoor air quality
›› Optimum airflow eliminates draft and insulates sound

VENTILATION
0%
start 6 months 12 months

How does it work?


1 Scheduled automatic filter cleaning
2 Dust collects in a dust box that’s integrated into the unit

CONTROL
SYSTEMS
3 The dust can easily be removed with a vacuum cleaner

airflow
direction

UNIQUE
PATENDED

& ACCESSORIES
SOLUTION

OPTIONS

Concealed ceiling units Round flow cassette


& PLATFORMS

›› Ideal for hotels and residential applications ›› Ideal for retail


TOOLS

›› Cleaning team /owner can clean the filter ›› Staff/owner can clean the filter
›› No need to use a ladder to reach the unit
More details
on page 34 More details
on page 22
Combination table
TECHNICAL
DRAWINGS

Split / Sky Air VRV Sky Air VRV


FDXM-F3 FXDQ-A3
FCAG-A FCAHG-G FXFQ-A
25 35 50 60 15 20 25 32 40 50 63
BAE20A62       BYCQ140DG9   
BAE20A82  
BYCQ140DGF9 (fine mesh)   
PREVIOUS

BAE20A102   

9
Multi zoning kit for
concealed ceiling units

The multi-zoning system is a room-by-room controller. It is fitted with motorised dampers, which immediately
adapt using Daikin ducted solutions. This system supports control of up to 8 zones via a centralised thermostat
located in the main room and individual thermostats for each of the zones.

Benefits How does it work?


Increased comfort
20°C
›› Increases comfort levels by allowing more individual
zone control 19°C
-- Up to 8 individual zones can be served thanks to separate
modulating dampers Zoning box:
-- Individual thermostat for room-by-room or zone-by-zone fully pre-assembled
control plenum with
21°C dampers

Easy to install

›› Automatic air flow adjustment according to the demand Individual zone thermostats
›› Easy to install, integrates with the Daikin indoor units and system
controls
›› Time saving as plenum comes fully pre-assembled with dampers,
and control boards Blueface - Airzone Airzone Zone Airzone Zone
Main Thermostat Thermostat Thermostat
›› Reduces the amount of refrigerant required in the installation ›› Color graphic interface ›› Graphic interface with ›› Thermostat with buttons
for controlling zones low-energy e-ink screen for controlling the
›› Wired communication for controlling zones temperature
›› Radio communication ›› Radio communication
Plug and play plenum Concealed ceiling unit

Motorized dampers Electronic control panel


AZCE6BLUEFACECB AZCE6THINKRB AZCE6LITERB

Compatibility
FDXM-F3 FBA-A ADEQ-C FXDQ-A3 FXSQ-A
Number of Dimensions
motorised dampers
Reference H x L x D (mm)
25 35 50 60 35 50 60 71 100 125 140 71 100 125 15 20 25 32 40 50 63 15 20 25 32 40 50 63 71 80 100 125 140

2
AZEZ6DAIST07XS2
930 x 300 x 454
• • • •
AZEZ6DAIST07S2 • • • •
3
AZEZ6DAIST07XS3
930 x 300 x 454
• • • •
AZEZ6DAIST07S3 • • • •
4
AZEZ6DAIST07S4 930 x 300 x 454 • • • •
Standard Ceiling
AZEZ6DAIST07M4 1,140 x 300 x 454 • • • • •
Void 5
AZEZ6DAIST07M5
1,425 x 300 x 454
• • • • •
AZEZ6DAIST07L5 • • • • • • •
6
AZEZ6DAIST07M6
1,638 x 300 x 454
• • • • •
AZEZ6DAIST07L6 • • • • • • •
7
AZEZ6DAIST07L7
1,425 x 515 x 454
• • • • • • •
AZEZ6DAIST07XL7 •
8
AZEZ6DAIST07L8
1,425 x 515 x 454
• • • • • • •
AZEZ6DAIST07XL8 •
Compact Ceiling 2 AZEZ6DAISL01S2 720 x 210 x 444 • • • • • •
Void 3 AZEZ6DAISL01S3 720 x 210 x 444 • • • • • •
4 AZEZ6DAISL01M4 930 x 210 x 444 • •
5 AZEZ6DAISL01L5 1,140 x 210 x 444 • • •
10
SKY AIR INTRO
INDOOR
UNITS
Infrastructure cooling

OUTDOOR
UNITS
Infrastructure cooling

AIR CURTAINS
BIDDLE
›› For rooms and enclosures that require round-the-clock cooling
›› Where continuous uptime is the absolute requirement for server data protection

Between
20-40%
sensible capacity

VENTILATION
increase
Reliable Efficient Flexible

Guaranteed system operation: Optimum return on investment: ›› Scalable in


›› Oversized indoor units boost cooling ›› Lowers running costs by using capacity
capacity and prevent freeze-ups on the highly efficient direct expansion ›› Improved infrastructure control and
indoor side cooling systems management
›› Wide operating range envelope: ›› Lower running costs compared to other ›› Lower physical footprint since no floor

CONTROL
SYSTEMS
operation range in cooling down DX systems and water based chillers. space is occupied
to -20°C and up to +52°C ›› Minimises environmental impact ›› Wide range of indoor units to suit
with A++ energy labels application preferences (ceiling
›› Reduces mechanical cooling and energy suspended cassettes, wall mounted
consumption with the free cooling indoors, concealed ceiling ducted type
option for single phase systems indoors)

& ACCESSORIES
OPTIONS
Duty rotation application example
SYSTEM 1 FBA140 IN OPERATION SYSTEM 1 FBA140 STANDBY
SYSTEM 2 FBA140 STANDBY SYSTEM 2 FBA140 IN OPERATION
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS

BRC1H51 or BRC1E53*
Standard includes duty
rotation functionality

RZAG100
RZAG100
PREVIOUS

BRC1H51W

11
"We were very happy to work with
Daikin in installing one of the latest
fully controllable systems with
operational flexibility, which met all
our requirements."
Retail shop representative

Shops
Reducing retail costs Check on
›› Open door trading thanks to Biddle air curtains are vital to minimise lifetime costs, while ensuring
›› Discreet with limited visual and operating impact compliance with the latest regulations.
›› Reduces energy usage and costs www.youtube.com/
›› Worry-free installation Whatever the site and requirements we can design DaikinEurope
›› User-friendly control a system that is economical, has low environmental
impact and uses the very latest technology. Our heat
Store & shop
In the current commercial environment, retailers are pumps extract heat from the outside air even in cold
under pressure to reduce both store development weather to warm the retail space and can be installed
and running costs. Legislation adds further financial either on roof tops or against walls - the ultimate in
pressure with different energy-efficient schemes. installation flexibility. And our air curtains solve that
Therefore affordable, energy-efficient solutions problem of comfort loss resulting from exterior doors.

"Leading edge design


in harmony with the construction
and interior design.“
Architect

Offices
Efficiency in the workplace

›› Fully flat cassette: Design and genius in one. consumption – creating the ideal working conditions
›› Cutting the cost of hot water. and minimising environmental impact.
›› Fresh air: A healthier office atmosphere.
›› Centralised control: Complete Daikin package for Daikin’s office air conditioning can be
office building management integrated into a whole climate control solution.
Heat recovery between components, free cooling
Efficient building and facilities management is key ventilation and free hot water production all result
to minimising operational costs. Daikin’s customised in lower running costs and minimum carbon
office solutions give you full control over energy emissions.
12
SKY AIR INTRO
“Total renovation and expansion of the
restaurant meant new air conditioning
equipment was required. Daikin was

INDOOR
the first and only supplier to contact as

UNITS
we had already had good experience in
the past!”
Owner of a highly-rated restaurant

OUTDOOR
UNITS
Restaurants
Perfect ambiance for dining

AIR CURTAINS
›› Ensures an even temperature distribution to create ventilation. That is exactly what Daikin’s concealed

BIDDLE
the perfect dining environment. ceiling units deliver through whisper quiet operation
›› Heat recovery ventilation keeps the air clean and improved comfort from the 3-step air flow
›› Highly energy efficient control.
›› Uses intelligent control systems operated from one These turn your customer’s restaurant into a
central location. comfortable, welcoming environment. And with
centralised control and easy scheduling for the
Nothing should distract diners from enjoying entire restaurant system, energy use is minimised

VENTILATION
the perfect ambience, and that ambience to reduce your customer’s running costs.
includes the optimum temperature and

CONTROL
SYSTEMS
“A reliable system
and guaranteed continuous

& ACCESSORIES
OPTIONS
operation are what count for me.”
General office manager
& PLATFORMS
TOOLS

IT rooms, laboratories and telecom shelters


Sky Air for infrastructure cooling

›› Continuous cooling operation. rotation between units after a certain period of use
TECHNICAL
DRAWINGS

›› Dedicated infrastructure cooling settings to ensure that at any time, one unit is working while
›› Unique selection method with capacity tables the other is available for maintenance.
down to -20°C outdoor temperature
›› Enhanced reliability thanks to assymetric combi- Given the critical importance of continuous cooling
nations (e.g. 125 class indoor + 100 class outdoor) for server rooms, the system can be managed via an
RTD-10 controller that can monitor and control up
Servers, especially racks of servers, generate a great to 8 indoor units either directly or via the building
deal of heat and this needs to be removed through management system (RTD-NET).
PREVIOUS

continuous cooling. This is achieved through duty


13
Sky Air, from high
specification, tailored
solutions to primary
cooling and heating

14
SKY AIR INTRO
Indoor
units

INDOOR
UNITS
A wide range of unified indoor units for the use

OUTDOOR
UNITS
with R-32 and R-410A refrigerant.

Products overview  16
Benefits overview 18

Ceiling mounted cassettes 22

AIR CURTAINS
FCAHG-G / 25

BIDDLE
FCAG-A / 26
FFA-A / 33


Concealed ceiling units 34


FDXM-F3 / 36

VENTILATION
FBA-A / 37
FDA-A / 41
FDQ-B 71
ADEQ-C 72
ABQ-C 73

Wall mounted units 42

CONTROL
SYSTEMS
FAA-A / 42

Ceiling suspended units 46


FHA-A / 46

& ACCESSORIES
FUA-A /  50

OPTIONS
AHQ-C 80

Floor standing units 52


FVA-A / 52
& PLATFORMS

Concealed floor standing units 55


TOOLS

FNA-A / 55
TECHNICAL
DRAWINGS
PREVIOUS

15
Indoor units

Product overview

Product
Type Model PG
name

360° air discharge for the highest efficiency and comfort


UNIQUE --High COP cassette ensures top performance for commercial applications
High COP, FCAHG-G 25 --Auto cleaning function ensures high efficiency
Round flow cassette --Intelligent sensors save energy and maximize comfort
--Flexibility to suit every room layout
360° air discharge for the highest efficiency and comfort
--Auto cleaning function ensures high efficiency
Ceiling UNIQUE --Intelligent sensors save energy and maximize comfort
mounted FCAG-A 26-29 --Flexibility to suit every room layout
Round flow cassette
cassette --Lowest installation height in the market
--27~29 dB(A) on low fan speed
Unique design in the market that integrates fully flat into the ceiling
--Perfect integration in standard architectural ceiling tiles
UNIQUE --Blend of iconic design and engineering excellence with a white or silver and white finish
Fully flat cassette FFA-A 33
--Intelligent sensors save energy and maximize comfort
--Flexibility to suit every room layout without changing the location of the unit!
--Quietest 600 x 600 cassette on the market
Slim design for flexible installation
NEW NEW --Compact dimensions enable installation in narrow ceiling voids
Slim concealed Auto Multi
ceiling unit
FDXM-F3 36 - Medium external static pressure up to 40Pa
cleaning zoning --Small capacity unit developed for small of well insulated rooms
option option --Auto cleaning function ensures high efficiency and reliability

Slimmest yet most powerfull medium static pressure unit on the market!
--Slimmest unit in class, only 245mm
Concealed ceiling unit
NEW --Low operating sound level
with medium ESP Multi FBA-A 37-40 --Medium external static pressure up to 150Pa facilitates using flexible ducts of
zoning varying lengths
option --Automatic air flow adjustment function measures the air volume and static pressure
and adjusts it towards the nominal air flow, guaranteeing comfort
ESP up to 200Pa, ideal for large sized buildings
--Discretely concealed in the ceiling: only the grilles are visible
Concealed ceiling unit with high ESP FDA-A 41 --Possibility to change ESP via wired remote control allows optimisation of the supply
Concealed air volume
ceiling --Flexible installation as the air suction direction can be altered from rear to bottom suction

ESP up to 250Pa, Ideal for extra large sized spaces


--Blends unobtrusively with any interior décor: only the suction and discharge grilles
Concealed ceiling unit with high ESP FDQ-B  71 are visible
--Up to 26.4kW in heating mode

Ideal for residential applications with false ceilings


--Energy label up to A
ADEQ-C 72 --Medium external static pressure up to 150Pa facilitates using flexible ducts of
Concealed ceiling unit varying lengths
--Slimmest unit in class, only 245mm
--Exclusively offered for pair applications

Ideal for medium sized shops with false ceilings


Concealed ceiling unit ABQ-C 73 --Discretely concealed in the ceiling: only the grilles are visible
--Best protection against possible water leakage

For rooms with no false ceilings nor free floor space


--The air is comfortably spread up- and downwards thanks to 5 different discharge angles
Wall
Wall mounted unit FAA-A 42-44 --Easy maintenance as this can be done from the front of the unit
mounted --Easy to install: 100 class is 35% lighter than previous model
--Flexible to install: pipe connection can be bottom, left or right

For wide rooms with no false ceilings nor free floor space
--Ideal for comfortable air flow in wide rooms thanks to Coanda effect
Ceiling suspended unit FHA-A 46-48 --Even rooms with ceilings up to 3.8m can be heated up or cooled down very easily!
--Can be mounted in corners or narrow spaces without any problem
Ceiling
suspended Unique Daikin unit for high rooms with no false ceilings nor free floor space
--Even rooms with ceilings up to 3.5m can be heated up or cooled down very easily!
UNIQUE FUA-A 50-51 --Flexibility to suit every room layout without changing the location of the unit!
4-way blow ceiling suspended unit --Optimum comfort guaranteed with automatic air flow adjustment to the required load
--The air is comfortably spread up- and downwards thanks to 5 different discharge angles

For wide rooms with no false ceilings nor free floor space
Ceiling suspended unit AHQ-C 80 --Guarantees a stable temperature

For spaces with high ceilings


--Ideal solution for commercial spaces with no or narrow false ceilings
Floor standing unit FVA-A 52-53 --Even rooms with very high ceilings can be heated up or cooled down very easily!
--Guarantees a stable temperature
Floor --Vertical and horizontal outblow
standing
Designed to be concealed in walls, only grilles remain visible
--Slimmest unit on the market with a depth of only 200mm!
Concealed floor standing unit FNA-A 55 --Both window sill or ducted installation are possible thanks to sufficient ESP
--Whisper quiet operation allows installation in any location

16
SKY AIR INTRO
Full R-32 Indoor units

line up
Outdoor unit combination
Capacity class

INDOOR
UNITS
Seasonal Smart
25 35 50 60 71 100 125 140 200 250
RZAG* RZASG* AZAS* RZQG* RZQSG * AZQS* RZQ*

      

OUTDOOR
UNITS
             

        

AIR CURTAINS
BIDDLE
        

            

VENTILATION
     

  

CONTROL
SYSTEMS
   

   

& ACCESSORIES
OPTIONS
       

           
& PLATFORMS
TOOLS

       

    

        
TECHNICAL
DRAWINGS

        
PREVIOUS

17
Indoor units

Benefits overview

Seasonal efficiency - Seasonal efficiency gives a more realistic indication on how efficient air conditioners operate
Smart use of energy over an entire heating or cooling season.
Inverter technology In combination with inverter controlled outdoor units
Home leave
During absence, the indoor temperature can be maintained at a certain level.
operation
We care

Fan only The air conditioner can be used as fan, blowing air without cooling or heating.
The filter automatically cleans itself. Simplicity of upkeep means optimum energy efficiency and maximum comfort
Auto cleaning filter
without the need for expensive or time-consuming maintenance.
The presence sensor directs the air away from any person detected in the room, when the air flow control is on.
Floor and presence
The floor sensor detects the average floor temperature and ensures an even temperature distribution between ceiling and
sensor
floor.

When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally
Draught prevention
and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired.
Comfort

Daikin indoor units are whisper quiet. Also the outdoor units are guaranteed
Whisper quiet
not to disturb the quiet of the neightbourhood.
Auto cooling-heating
Automatically selects cooling or heating mode to achieve the set temperature.
changeover
Air treatment

Air filter Removes airborne dust particles to ensure a steady supply of clean air.
Humidity
control

Dry programme Allows humidity levels to be reduced without variations in room temperature.

Ceiling soiling
A special function prevents air blowing out too long in horizontal position, to prevent ceiling stains.
prevention
Possibility to select automatic vertical moving of the air discharge louvre, for uniform air flow and temperature
Vertical auto swing
distribution.
Air flow

Fan speed steps Allows to select up to the given number of fan speed.

Individual flap Individual flap control via the wired remote controller makes it simple to fix the position of each flap individually,
control to suit any new room configuration. Optional closure kits are available as well.

Online controller Can control and monitor the status of a heating system or up to 50 split air conditioning units
Remote control & timer

Weekly timer Timer can be set to start operation anytime on a daily or weekly basis

Infrared remote
Infrared remote control with LCD to start, stop and regulate the air conditioner from a distance.
control

Wired remote control Wired remote control to start, stop and regulate the air conditioner from a distance.

Centralised control Centralised control to start, stop and regulate several air conditioners from one central point.

Multi zoning NEW Allows up to 6 individual climate zones with one indoor unit

Infrastructure Remove in a reliable, efficient and flexible way the heat constantly generated by the IT and server equipment
cooling to ensure maximum uptime while offering the best return on investment.
Auto-restart The unit restarts automatically at the original settings after power failure.
Other functions

Self-diagnosis Simplifies maintenance by indicating system faults or operating anomalies.

Drain pump kit Facilitates condensation draining from the indoor unit.
Twin/triple/double 2, 3 or 4 indoor units can be connected to only 1 outdoor unit. All indoor units operate within the same mode (cooling or
twin application heating) from one remote control.
Multi model Up to 5 indoor units (even different capacities) can be connected to a single outdoor unit. All indoor units can individually
application be operated within the same mode.
VRV for residential Up to 9 indoor units (even different capacities and up to 71 class) can be connected to a single outdoor unit.
application All indoor units can individually be operated within the same mode.
18
SKY AIR INTRO
Indoor units
4-Way blow
Ceiling mounted Ceiling Ceiling Wall Floor
Concealed ceiling ceiling
cassette suspended suspended mounted standing
units suspended
units units units unit units
unit

FCA HG -G FC AG - A FFA-A FD X M- F3 FB A- A FDA- A FDQ - B A DE Q - C A BQ - C FHA-A FUA-A AHQ-C FAA-A FVA-A F NA - A

INDOOR
UNITS
• • • • • •  • • • • •
• • • • • • •  • • • • • • •
• • • • • • •  • • • • •
• • • • • • •  • • • • • • •

OUTDOOR
UNITS
• •  NEW

• • •

AIR CURTAINS
• • • •

BIDDLE
• • • • •
• • • • • • • • • • • • • • •

• • • • • • • • • • • • • • •

VENTILATION
• • • • • • • • • • • •

• • •

CONTROL
SYSTEMS
• • • • • • •
5 5 3 3 3 3 2 3 3 3 3 3 3 3 3

• • • •

& ACCESSORIES
OPTIONS
• NEW • NEW • NEW • NEW • NEW • NEW • NEW • NEW • NEW • NEW • NEW • NEW

• • • •
depending on • • • • • • • • • • •
controller

optional optional optional optional optional optional optional optional optional standard optional optional
& PLATFORMS

optional optional optional optional optional optional optional optional standard optional optional optional optional optional optional
TOOLS

optional optional optional optional optional optional optional optional optional optional optional optional optional

 NEW
 NEW

• • • • • • • • • • • • •
• • • • • • • • • • • • • • •
TECHNICAL
DRAWINGS

• • • • • • • • • • • •
standard standard standard standard standard • optional optional standard optional

• • • • • • • • • • •
• • • • • • •
PREVIOUS

• • • • • •
19
Sky Air

FULLY FLAT CASSETTE CONCEALED CEILING UNIT

CONCEALED FLOOR 4-WAY BLOW CEILING


STANDING UNIT SUSPENDED CASSETTE

20
WALL MOUNTED UNIT

FILTER, IDEAL FOR CLOTHING SHOPS


AUTO CLEANING CASSETTE WITH FINE MESH
CEILING SUSPENDED UNIT

21
Sky Air

TECHNICAL TOOLS OPTIONS CONTROL BIDDLE OUTDOOR INDOOR


PREVIOUS VENTILATION SKY AIR INTRO
DRAWINGS & PLATFORMS & ACCESSORIES SYSTEMS AIR CURTAINS UNITS UNITS
ARGUE CARDS

 FCAHG-G/FCAG-A

Auto cleaning cassette

Why choose a round flow cassette?


• 360° air discharge for optimum comfort
• Intelligent sensors for maximum efficiency

More energy efficient and user-friendly


than any other cassette
›› Running costs are reduced
by 50% compared with standard solutions
›› Automatic filter cleaning.
›› Less time is required to maintain the filter:
dust can be removed easily with a vacuum cleaner
without opening the unit.

Finer mesh panel


›› For dust prone areas (i.e. clothing and book shops)
a finer mesh panel (BYCQ140DGF9) ensures
consistent performance and optimum air
distribution
›› Clean ceilings ensured thanks to fine mesh and
clean filter

BYCQ140DG9 BYCQ140DGF9
Auto-cleaning panel
Auto-cleaning panel
with fine mesh filter

White with grey louvers White with grey louvers

Auto-cleaning cassette for maintaining Dust can be removed easily


the optimum store atmosphere with a vacuum cleaner
without opening the unit.

Air distribution with a clean filter Air distribution with a dusty filter

22
SKY AIR INTRO
INDOOR
UNITS
References Energy consumption
(kWh)
9000
Coral shop, UK 8000 Up to 50% savings Standard round
Running costs were reduced flow cassette
7000 thanks to
by up to 50% compared 6000 automated cleaning
with standard solutions

OUTDOOR
5000

UNITS
thanks to clean filter Auto cleaning cassette
4000
3000
2000
1000
0
Cumulative energy comparison over 12 months  July Aug. Sept. Oct. Nov. Dec. Jan. Feb. March April May June July

AIR CURTAINS
BIDDLE
360° air discharge for improved comfort
›› Industry-first and proven design. Benefits for the installer
›› Product with unique functions in this market.
›› Less time needed for onsite maintenance.
Intelligent sensors improve efficiency ›› Use the controller to individually open or close any

VENTILATION
and comfort even more of the four flaps to easily adapt to a changing room layout.
›› The presence sensor ›› Easy set-up of the sensor option to improve comfort and
adjusts the set point if save energy.
no one is detected in
the room leading to up
to 27% savings. It also presence floor sensor
Benefits for the consultant
automatically directs air sensor ›› Product with unique functions in this market.
flow away from any person ›› Designed for use in all types and sizes of commercial offices

CONTROL
SYSTEMS
to avoid draught. and retail environments.
›› The infrared floor sensor detects the average ›› Ideal product for improving BREEAM score/EPBD in
floor temperature and ensures even temperature combination with Sky Air or VRV IV heat pump units.
distribution between ceiling and floor to prevent
cold feet.
Benefits for the end user
›› Designed for use in all types and sizes of commercial offices

& ACCESSORIES
and retail environments.

OPTIONS
Flexible installation ›› Perfect environment conditions:
›› Flaps can be individually controlled or closed no more draughts or cold feet.
using the wired remote control, to suit room ›› Save up to 50% on running costs with the auto-cleaning
configuration. Optional closure kits are panel, which also facilitates maintenance.
also available. ›› Your customers can save up to 27% on their energy bills
thanks to the sensor option.
›› Flexible use of space thanks to individual flap control.
& PLATFORMS
TOOLS

Marketing tools
›› Visit the website:
TECHNICAL
DRAWINGS

https://www.daikin.eu/en_us/product-group/round-flow-cassette.html

www.youtube.com/DaikinEurope
PREVIOUS

23
24
SKY AIR INTRO
FCAHG-G + RZAG-MV1/MY1

High COP, round flow cassette


360° air discharge for optimum efficiency and comfort

INDOOR
ʯʯ High COP cassette ensures top performance, great savings

UNITS
in energy consumption and a comfortable environment for
commercial applications
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Combining with R-32 Bluevolution technology, reduces
environmental impact with 68% compared to R-410A, leads
FCAHG-G
directly to lower energy consumption thanks to its high energy
efficiency and has up to lower 16% refrigerant charge
ʯʯ Automatic filter cleaning results in higher efficiency & comfort

OUTDOOR
UNITS
and lower maintenance costs. 2 filters available: standard filter and
finer mesh filter (for fine dust applications e.g. clothing shops)
ʯʯ Two optional intelligent sensors improve energy efficiency and comfort.
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
ʯʯ Modern style decoration panel is available in 3 different variations: RZAG100-140MV1_MY1 BRC1H51W BRP069A81
white (RAL9010) with grey louvers, full white (RAL9010) or auto
cleaning panel

AIR CURTAINS
ʯʯ 5 different fan speeds available for maximum comfort ʯʯ Standard drain pump with 675mm lift increases flexibility

BIDDLE
ʯʯ Reduced energy consumption thanks to specially developed small and installation speed
tube heat exchanger, DC fan motor and drain pump
ʯʯ Optional fresh air intake
ʯʯ Branch duct discharge allows to optimize air distribution in
irregular shaped rooms or to supply air to small adjacent rooms

VENTILATION
Efficiency data FCAHG + RZAG 71G + 71MV1 100G + 100MV1 125G + 125MV1 140G + 140MV1 71G + 71MY1 100G + 100MY1 125G + 125MY1 140G + 140MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5
Seasonal efficiency Cooling Energy efficiency class A++ - A++ -
(according to Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
EN14825) SEER 7.72 7.35 8.02 7.93 7.72 7.35 8.02 7.93
Annual energy consumption kWh 308 452 905 1,014 308 452 905 1,014
Heating (Average Energy efficiency class A++ - A++ -
climate) Pdesign kW 4.70 9.52 4.70 9.52
SCOP/A 4.61 4.81 4.53 4.44 4.61 4.81 4.53 4.44

CONTROL
Annual energy consumption kWh 1,427 2,771 2,942 3,002 1,427 2,771 2,942 3,002

SYSTEMS
Indoor unit FCAHG 71G 100G 125G 140G 71G 100G 125G 140G
Dimensions Unit HeightxWidthxDepth mm 288x840x840
Weight Unit kg 25
Air filter Type Resin net
Decoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW
- full white / BYCQ140D - white with grey louvers
Colour Pure White (RAL 9010)
Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950

& ACCESSORIES
Weight kg 10.3 / 10.3 / 5.4 / 5.4

OPTIONS
Fan Air flow rate Cooling Low/Medium/High m³/min 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5
Heating Low/Medium/High m³/min 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5
Sound power level Cooling dBA 53 61 53 61
Heating dBA 53 61 53 61
Sound pressure level Cooling Low/High dBA 29/36 33/44 35/45 37/45 29/36 33/44 35/45 37/45
Heating Low/High dBA 29/36 33/44 35/45 37/45 29/36 33/44 35/45 37/45
Control systems Infrared remote control BRC7FA532F
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
& PLATFORMS

Outdoor unit RZAG 71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1
Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
TOOLS

Weight Unit kg 70 92 70 92
Sound power level Cooling dBA 64 66 69 70 65 66 69 70
Sound pressure level Cooling Nom. dBA 46 47 50 51 46 47 50 51
Heating Nom. dBA 49 51 52 49 51 52
Operation range Cooling Ambient Min.~Max. °CDB -20~52
Heating Ambient Min.~Max. °CWB -20~18.0
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.95/1.99 3.75/2.53
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 55 85 55 85
TECHNICAL
DRAWINGS

length System Equivalent m 75 100 75 100


Chargeless m 40
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

(1) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.
(2) EER/COP according to Eurovent 2012, for use outside EU only
(3) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environ-
PREVIOUS

ments exposed to concentrations of dirt.


(4) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

25
FCAG-A + RZAG-MV1/MY1

Round flow cassette


360° air discharge for optimum efficiency and comfort
ʯʯ Combination with Sky Air Alpha-series ensures best in class
quality, highest efficiency and performance
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Combining with R-32 Bluevolution technology, reduces
environmental impact with 68% compared to R-410A, leads
directly to lower energy consumption thanks to its high energy
efficiency and has up to lower 16% refrigerant charge FCAG-A
ʯʯ Automatic filter cleaning results in higher efficiency & comfort
and lower maintenance costs. 2 filters available: standard filter and
finer mesh filter (for fine dust applications e.g. clothing shops)
ʯʯ Two optional intelligent sensors improve energy efficiency and comfort.
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
ʯʯ Modern style decoration panel is available in 3 different variations:
white (RAL9010) with grey louvers, full white (RAL9010) or auto
cleaning panel
ʯʯ 5 different fan speeds available for maximum comfort RZAG100-140MV1_MY1 BRC1H51W BRP069A81
ʯʯ Reduced energy consumption thanks to specially developed small
tube heat exchanger, DC fan motor and drain pump
ʯʯ Optional fresh air intake
ʯʯ Branch duct discharge allows to optimize air distribution in
irregular shaped rooms or to supply air to small adjacent rooms
ʯʯ Standard drain pump with 675mm lift increases flexibility and
installation speed

Efficiency data FCAG + RZAG 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 71A + 71MY1 100A + 100MY1 125A + 125MY1 140A + 140MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5
Seasonal efficiency Cooling Energy efficiency class A++ - A++ -
(according to Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
EN14825) SEER 6.86 7.14 7.80 7.17 6.86 7.14 7.80 7.17
Annual energy consumption kWh 347 466 931 1,121 347 466 931 1,121
Heating (Average Energy efficiency class A+ A++ - A+ A++ -
climate) Pdesign kW 4.70 7.80 9.52 4.70 7.80 9.52
SCOP/A 4.41 4.61 4.34 4.41 4.61 4.34
Annual energy consumption kWh 1,492 2,369 3,071 1,492 2,369 3,071

Indoor unit FCAG 71A 100A 125A 140A


71A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840 204x840x840 246x840x840
Weight Unit kg 21 24 21 24
Air filter Type Resin net
Decoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW
- full white / BYCQ140D - white with grey louvers
Colour Pure White (RAL 9010)
Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950
Weight kg 10.3 / 10.3 / 5.4 / 5.4
Fan Air flow rate Cooling Low/Medium/High m³/min 9.3/12.5/15.3 12.4/17.6/22.8 12.4/19.2/26.0 9.3/12.5/15.3 12.4/17.6/22.8 12.4/19.2/26.0
Heating Low/Medium/High m³/min 9.1/12.1/15.0 12.4/17.6/22.8 12.4/19.2/26.0 9.1/12.1/15.0 12.4/17.6)/22.8 12.4/19.2/26.0
Sound power level Cooling dBA 51 54 58 51 54 58
Heating dBA 51 54 58 51 54 58
Sound pressure level Cooling Low/High dBA 28/35 29/37 29/41 28/35 29/37 29/41
Heating Low/High dBA 28/33 29/37 29/41 28/33 29/37 29/41
Control systems Infrared remote control BRC7FA532F
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RZAG 71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1
Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 70 92 78 70 92
Sound power level Cooling dBA 64 66 69 73 65 66 69 70
Sound pressure level Cooling Nom. dBA 46 47 50 54 46 47 50 51
Heating Nom. dBA 49 51 52 57 49 51 52
Operation range Cooling Ambient Min.~Max. °CDB -20~52 -15~46 -20~52
Heating Ambient Min.~Max. °CWB -20~18.0 -15~15.5 -20~18.0
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.90/1.96 2.95/1.99 3.75/2.53
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 55 85 50 55 85
length System Equivalent m 75 100 70 75 100
Chargeless m 40 30 40
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

(1) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.
(2) EER/COP according to Eurovent 2012, for use outside EU only
(3) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environ-
ments exposed to concentrations of dirt.
(4) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

26
SKY AIR INTRO
FCAG-A + RZASG-MV1/MY1

Round flow cassette


360° air discharge for optimum efficiency and comfort

INDOOR
UNITS
ʯʯ Combination with Sky Air Advance-series ensures good value for
money for all types of commercial applications
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Combining with R-32 Bluevolution technology, reduces
environmental impact with 68% compared to R-410A, leads
directly to lower energy consumption thanks to its high energy FCAG-A
efficiency and has up to lower 16% refrigerant charge
ʯʯ Automatic filter cleaning results in higher efficiency & comfort

OUTDOOR
UNITS
and lower maintenance costs. 2 filters available: standard filter and
finer mesh filter (for fine dust applications e.g. clothing shops)
ʯʯ Two optional intelligent sensors improve energy efficiency and
comfort
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit! RZASG100-140MV1_MY1 BRC1H51W BRP069A81
ʯʯ Modern style decoration panel is available in 3 different variations:

AIR CURTAINS
white (RAL9010) with grey louvers, full white (RAL9010) or auto

BIDDLE
cleaning panel

Efficiency data FCAG + RZASG 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 100A + 100MY1 125A + 125MY1 140A + 140MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4

VENTILATION
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Seasonal efficiency Cooling Energy efficiency class A++ - A++ -
(according to Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
EN14825) SEER 6.47 6.55 5.76 6.53 6.55 5.76 6.53
Annual energy consumption kWh 368 507 1,261 1,231 507 1,261 1,231
Heating (Average Energy efficiency class A A+ - A+ -
climate) Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 4.00 4.17 4.05 4.31 4.17 4.05 4.31
Annual energy consumption kWh 1,575 2,016 2,074 2,534 2,016 2,074 2,534

CONTROL
SYSTEMS
Indoor unit FCAG 71A 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840
Weight Unit kg 21 24
Air filter Type Resin net
Decoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW - full
white / BYCQ140D - white with grey louvers
Colour Pure White (RAL 9010)
Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950
Weight kg 10.3 / 10.3 / 5.4 / 5.4

& ACCESSORIES
Fan Air flow rate Cooling Low/Medium/High m³/min 9.3/12.5/15.3 12.4/17.6/22.8 12.4/19.2/26.0 12.4/17.6/22.8 12.4/19.2/26.0

OPTIONS
Heating Low/Medium/High m³/min 9.1/12.1/15.0 12.4/17.6/22.8 12.4/19.2/26.0 12.4/17.6/22.8 12.4/19.2/26.0
Sound power level Cooling dBA 51 54 58 54 58
Heating dBA 51 54 58 54 58
Sound pressure level Cooling Low/High dBA 28/35 29/37 29/41 29/37 29/41
Heating Low/High dBA 28/33 29/37 29/41 29/37 29/41
Control systems Infrared remote control BRC7FA532F
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RZASG 71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1
& PLATFORMS

Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320


TOOLS

Weight Unit kg 60 70 78 70 77
Sound power level Cooling dBA 65 70 71 73 70 71 73
Sound pressure level Cooling Nom. dBA 46 53 54 53 54
Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/Gas mm 9.52/15.9
TECHNICAL
DRAWINGS

Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16

(1) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.
(2) EER/COP according to Eurovent 2012, for use outside EU only
PREVIOUS

(3) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environ-
ments exposed to concentrations of dirt.
(4) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

27
FCAG-A + AZAS-MV1/MY1

Round flow cassette


360° air discharge for optimum efficiency and comfort

ʯʯ Ideal solution for small businesses and shops


ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Combining with R-32 Bluevolution technology, reduces
environmental impact with 68% compared to R-410A, leads
directly to lower energy consumption thanks to its high energy
efficiency and has up to lower 16% refrigerant charge FCAG-A
ʯʯ Automatic filter cleaning results in higher efficiency & comfort
and lower maintenance costs. 2 filters available: standard filter and
finer mesh filter (for fine dust applications e.g. clothing shops)
ʯʯ Two optional intelligent sensors improve energy efficiency and
comfort
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
ʯʯ Modern style decoration panel is available in 3 different variations: AZAS71MV1 BRC1H51W BRP069A81
white (RAL9010) with grey louvers, full white (RAL9010) or auto
cleaning panel

Efficiency data FCAG + AZAS 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 100A + 100MY1 125A + 125MY1 140A + 140MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Seasonal efficiency Cooling Energy efficiency class A+ - A+ -
(according to Pdesign kW 6.80 9.50 12.1 13.0 9.50 12.1 13.0
EN14825) SEER 5.87 5.67 5.40 6.00 5.67 5.40 6.00
Annual energy consumption kWh 405 586 1,345 1,300 586 1,345 1,300
Heating (Average Energy efficiency class A - A -
climate) Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 4.00 3.85 3.80 4.31 3.85 3.80 4.31
Annual energy consumption kWh 1,575 2,182 2,211 2,534 2,182 2,211 2,534

Indoor unit FCAG 71A 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840
Weight Unit kg 21 24
Air filter Type Resin net
Decoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW - full
white / BYCQ140D - white with grey louvers
Colour Pure White (RAL 9010)
Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950
Weight kg 10.3/5.4/10.3/5.4
Fan Air flow rate Cooling Low/Medium/High m³/min 9.3/12.5/15.3 12.4/17.6/22.8 12.4/19.2/26.0 12.4/17.6/22.8 12.4/19.2 (0.000)/26.0
Heating Low/Medium/High m³/min 9.1/12.1/15.0 12.4/17.6/22.8 12.4/19.2/26.0 12.4/17.6/22.8 12.4/19.2 (0.000)/26.0
Sound power level Cooling dBA 51 54 58 54 58
Heating dBA 51 54 58 54 58
Sound pressure level Cooling Low/High dBA 28/35 29/37 29/41 29/37 29/41
Heating Low/High dBA 28/33 29/37 29/41 29/37 29/41
Control systems Infrared remote control BRC7FA532F
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit AZAS 71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 78 70 77
Sound power level Cooling dBA 65 70 71 73 70 71 73
Sound pressure level Cooling Nom. dBA 46 53 54 53 54
Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -5~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 30
length System Equivalent m 50
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16
(1) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.
(2) EER/COP according to Eurovent 2012, for use outside EU only
(3) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environ-
ments exposed to concentrations of dirt.
(4) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

28
SKY AIR INTRO
FCAG-A + RXM-M9 Split

Round flow cassette


360° air discharge for optimum efficiency and comfort

INDOOR
UNITS
ʯʯ Combination with split outdoor units is ideal for small retail,
offices or residential applications
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Combining with R-32 Bluevolution technology, reduces
environmental impact with 68% compared to R-410A, leads
directly to lower energy consumption thanks to its high energy FCAG-A
efficiency and has up to lower 16% refrigerant charge
ʯʯ Automatic filter cleaning results in higher efficiency & comfort

OUTDOOR
UNITS
and lower maintenance costs. 2 filters available: standard filter and
finer mesh filter (for fine dust applications e.g. clothing shops)
ʯʯ Two optional intelligent sensors improve energy efficiency and
comfort
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit! RXM20-35M9 BRC1H51W BRP069A81
ʯʯ Lowest installation height in the market: 214mm

AIR CURTAINS
ʯʯ Modern style decoration panel is available in 3 different variations:

BIDDLE
white (RAL9010) with grey louvers, full white (RAL9010) or auto
cleaning panel

Efficiency data FCAG + RXM 35A + 35M9 50A + 50M9 60A + 60M9
Cooling capacity Nom. kW 3.50 5.00 5.70

VENTILATION
Heating capacity Nom. kW 4.20 6.00 7.00
Power input Cooling Nom. kW 0.94 1.39 1.72
Heating Nom. kW 1.11 1.62 2.07
Seasonal efficiency Cooling Energy efficiency class A++
(according to Pdesign kW 3.50 5.00 5.70
EN14825) SEER 6.35 6.54 6.40
Annual energy consumption kWh 193 266 312
Heating (Average Energy efficiency class A++ A+
climate) Pdesign kW 3.32 4.36 4.71
SCOP/A 4.90 4.30 4.20

CONTROL
SYSTEMS
Annual energy consumption kWh 948 1,419 1,569

Indoor unit FCAG 35A 50A 60A


Dimensions Unit HeightxWidthxDepth mm 204x840x840
Weight Unit kg 18 19
Air filter Type Resin net
Decoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW
- full white / BYCQ140D - white with grey louvers
Colour Pure White (RAL 9010)
Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950

& ACCESSORIES
Weight kg 10.3 / 10.3 / 5.4 / 5.4

OPTIONS
Fan Air flow rate Cooling Low/Medium/High m³/min 8.7/10.6/12.5 8.7/10.7/12.6 8.7/11.2/13.6
Heating Low/Medium/High m³/min 9.3/11.6/13.9 8.7/10.7/12.6 8.7/11.2/13.6
Sound power level Cooling dBA 49 51
Heating dBA 49 51
Sound pressure level Cooling Low/High dBA 27/31 28/33
Heating Low/High dBA 27/31 28/33
Control systems Infrared remote control BRC7FA532F
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
& PLATFORMS

Outdoor unit RXM 35M9 50M9 60M9


TOOLS

Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300


Weight Unit kg 32 47
Sound power level Cooling dBA 61 62 63
Heating dBA 61 62 63
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-32
GWP 675.0
Charge kg/TCO2Eq 0.76/0.52 1.40/0.95 1.45/0.98
TECHNICAL
DRAWINGS

Piping connections Liquid OD mm 6,35 6,4


Gas OD mm 9.50 12.7
Piping length OU - IU Max. m 20.0 30
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Current - 50Hz Maximum fuse amps (MFA) A 10 15
(1) EER/COP according to Eurovent 2012, for use outside EU only
(2) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.
(3) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environ-
PREVIOUS

ments exposed to concentrations of dirt.


(4) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

29
ARGUE CARDS

Fully Flat Cassette


 Design & Genius in one

Why choose fully flat cassette


• Unique design in the market that integrates Benefits for the installer
››Unique product in the market!
fully flat into the ceiling ››Most quiet unit (25dBA)
››The user-friendly remote control, available in several
• Advanced technology and top efficiency combined languages, enables the easy set-up of sensor option
and control of the individual flap position
• Most quiet cassette available on the market ››Meeting European design taste.

Benefits for the consultant


››Unique product in the market!
FFA-A ››Blends seamlessly in any modern office
interior design
››Ideal product to improve BREEAM score/EPBD
in combination with Sky Air (FFA-A) or VRV IV heat
pump units (FXZQ-A).

Benefits for the end user


››Engineering excellence and unique design in one
››Most quiet unit (25dBA)
››Perfect working conditions: no more cold draughts
››Save up to 27% on your energy bill thanks
to the optional sensors
››Flexible usage of space and suits any room
configuration thanks to individual flap control
››User-friendly remote control, available
in several languages.

Choice between grey or white panel

30
SKY AIR INTRO
INDOOR
UNITS
Unique design

OUTDOOR
›› Fully integrated in the one ceiling tile, enabling

UNITS
›› Designed by a European design office to fully
meet the European taste. lights, speakers and sprinklers to be installed in
›› Fully flat into the ceiling, leaving only 8mm. adjoining ceiling tiles.
›› Decoration panel available in 2 colours
(white and white-silver).

AIR CURTAINS
BIDDLE
VENTILATION
Differentiating in technology being directed towards occupants.
Optional presence sensor
Optional floor sensor
›› When the room is empty, it can adjust the set
›› Detects the temperature difference and
temperature or switch off the unit – saving
re-directs the airflow to ensure even

CONTROL
SYSTEMS
energy.
temperature distribution.
›› When people are detected, the direction of
the airflow is adapted to avoid cold draughts

& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS

Other benefits
Top efficiency
* ›› Individual flap control: easily control one or more
›› Seasonal efficiency labels up to A
++
flaps via the wired remote controller (BRC1E*)
›› When the room is empty, the sensor option can when rearranging the room. When fully closing
adjust the set temperature or switch off the unit – or blocking the flaps, the option “Sealing member
saving up to 27% energy. of air discharge outlet” is needed.
TECHNICAL
DRAWINGS

›› Most silent cassette in the market (25dBA),


* for FFA25,35A in combination with RXM25,35M9 important for office applications.

Marketing tools
›› https://www.daikin.eu/en_us/product-group/fully-flat-cassette.html
PREVIOUS

›› www.youtube.com/DaikinEurope

31
32
SKY AIR INTRO
FFA-A + RXM-M9 Split

Fully flat cassette


Unique design in the market that integrates fully flat into
the ceiling

INDOOR
UNITS
ʯʯ Fully flat integration in standard architectural ceiling tiles, leaving
only 8mm
ʯʯ Remarkable blend of iconic design and engineering excellence
with an elegant finish in white or a combination of silver and
white
ʯʯ Unified indoor unit range for R-32 and R-410A FFA-A
ʯʯ Combining with R-32 Bluevolution technology, reduces
environmental impact with 68% compared to R-410A, leads

OUTDOOR
directly to lower energy consumption thanks to its high energy

UNITS
efficiency and has up to lower 16% refrigerant charge
ʯʯ Two optional intelligent sensors improve energy efficiency and comfort

RXM20-35M9 BRC1H51W BRP069A81


ʯʯ Individual flap control: flexibility to suit every room layout without

AIR CURTAINS
changing the location of the unit!
ʯʯ Reduced energy consumption thanks to specially developed small

BIDDLE
tube heat exchanger, DC fan motor and drain pump
ʯʯ Optional fresh air intake
ʯʯ Branch duct discharge allows to optimize air distribution in
irregular shaped rooms or to supply air to small adjacent rooms
ʯʯ Standard drain pump with 630mm lift increases flexibility and
installation speed

VENTILATION
Efficiency data FFA + RXM 25A + 25M9 35A + 35M9 50A + 50M9 60A + 60M9
Cooling capacity Nom. kW 2.50 3.40 5.00 5.70
Heating capacity Nom. kW 3.20 4.20 5.80 7.00
Power input Cooling Nom. kW 0.55 0.89 1.54 1.87
Heating Nom. kW 0.82 1.20 1.66 2.05
Seasonal efficiency Cooling Energy efficiency class A++ A+
(according to Pdesign kW 2.50 3.40 5.00 5.70
EN14825) SEER 6.17 6.38 5.98 5.76
Annual energy consumption kWh 142 186 292 347
Heating (Average Energy efficiency class A+ A A+

CONTROL
SYSTEMS
climate) Pdesign kW 2.31 3.10 3.84 3.96
SCOP/A 4.24 4.10 3.90 4.04
Annual energy consumption kWh 762 1,058 1,377 1,372

Indoor unit FFA 25A 35A 50A 60A


Dimensions Unit HeightxWidthxDepth mm 260x575x575
Weight Unit kg 16.0 17.5
Air filter Type Resin net
Decoration panel Model BYFQ60C2W1W/BYFQ60C2W1S/BYFQ60B2W1/BYFQ60B3W1

& ACCESSORIES
Colour White (N9.5)/SILVER/White (RAL9010)/WHITE (RAL9010)

OPTIONS
Dimensions HeightxWidthxDepth mm 46x620x620 / 46x620x620 / 55x700x700 / 55x700x700
Weight kg 2.8/2.8/2.7/2.7
Fan Air flow rate Cooling Low/Medium/High m³/min 6.5/8.0/9.0 6.5/8.5/10.0 7.5/10.0/12.0 9.5/12.5/14.5
Heating Low/Medium/High m³/min 6.5/8.0/9.0 6.5/8.5/10.0 7.5/10.0/12.0 9.5/12.5/14.5
Sound power level Cooling dBA 48 51 56 60
Sound pressure level Cooling Low/High dBA 25.0/31.0 25.0/34.0 27.0/39.0 32.0/43.0
Heating Low/High dBA 25.0/31.0 25.0/34.0 27.0/39.0 32.0/43.0
Control systems Infrared remote control BRC7EB530W (standard panel) / BRC7F530W (white panel) / BRC7F530S (grey panel)
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
& PLATFORMS

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240


TOOLS

Outdoor unit RXM 25M9 35M9 50M9 60M9


Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300
Weight Unit kg 32 47
Sound power level Cooling dBA 59 61 62 63
Heating dBA 59 61 62 63
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-32
GWP 675.0
TECHNICAL
DRAWINGS

Charge kg/TCO2Eq 0.76/0.52 1.40/0.95 1.45/0.98


Piping connections Liquid OD mm 6,35 6,4
Gas OD mm 9.50 12.7
Piping OU - IU Max. m 20.0 30
length System Chargeless m 10.0 -
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Current - 50Hz Maximum fuse amps (MFA) A 10 15
PREVIOUS

(1) EER/COP according to Eurovent 2012, for use outside EU only.


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

33
ARGUE CARDS

Auto cleaning filter for


concealed ceiling units

The unique automatic cleaning filter achieves higher efficiency


and comfort with lower maintenance costs

Reduce running costs


airflow
›› Automatic filter cleaning ensures low maintenance costs direction
because the filter is always clean

Efficiency profile change for duct indoor unit during operation


100% Up to 20%
Energy saved UNIQUE
Gradual loss of thanks to Patents
efficiency due automatic filter pending
to dirty filter cleaning

0%
start 6 months 12 months

Minimal time required for filter cleaning


›› The dust box can be emptied with a vacuum cleaner for fast
and easy cleaning
›› No more dirty ceilings

Improved indoor air quality


›› Optimum airflow eliminates draft and insulates sound How does it work?
Superb reliability 1 Scheduled automatic filter
›› Prevents clogged filters for seamless operation cleaning
2 Dust collects in a dust box that’s
Unique technology integrated into the unit
›› Unique and innovative filter technology inspired 3 The dust can easily be removed
by the Daikin auto cleaning cassette with a vacuum cleaner

Combination table Specifications

Split / Sky Air VRV BAE20A62 BAE20A82 BAE20A102


FDXM-F3 FXDQ-A3
Heigth (mm) 212
25 35 50 60 15 20 25 32 40 50 63 Width (mm) 764 964 1164
BAE20A62      
Width (mm) 984 1094 1294
BAE20A82   (incl. hanger bracket)

BAE20A102    Depth (mm) 201

34
SKY AIR INTRO
ARGUE CARDS

Multi zoning kit for


concealed ceiling units

INDOOR
UNITS
OUTDOOR
UNITS
The multi-zoning system is a room-by-room controller. It is fitted with motorised dampers, which immediately
adapt using Daikin ducted solutions. This system supports control of up to 8 zones via a centralised thermostat
located in the main room and individual thermostats for each of the zones.

Benefits How does it work?

AIR CURTAINS
BIDDLE
Increased comfort
20°C
›› Increases comfort levels by allowing more individual
zone control 19°C
-- Up to 8 individual zones can be served thanks to separate
modulating dampers Zoning box:
-- Individual thermostat for room-by-room or zone-by-zone fully pre-assembled

VENTILATION
control plenum with
21°C dampers

Easy to install

›› Automatic air flow adjustment according to the demand Individual zone thermostats
›› Easy to install, integrates with the Daikin indoor units and system
controls
›› Time saving as plenum comes fully pre-assembled with dampers,

CONTROL
SYSTEMS
and control boards Blueface - Airzone Airzone Zone Airzone Zone
Main Thermostat Thermostat Thermostat
›› Reduces the amount of refrigerant required in the installation ›› Color graphic interface ›› Graphic interface with ›› Thermostat with buttons
for controlling zones low-energy e-ink screen for controlling the
›› Wired communication for controlling zones temperature
›› Radio communication ›› Radio communication
Plug and play plenum Concealed ceiling unit

& ACCESSORIES
OPTIONS
Motorized dampers Electronic control panel
AZCE6BLUEFACECB AZCE6THINKRB AZCE6LITERB

Compatibility
FDXM-F3 FBA-A ADEQ-C FXDQ-A3 FXSQ-A
& PLATFORMS

Number of Dimensions
motorised dampers
Reference H x L x D (mm)
25 35 50 60 35 50 60 71 100 125 140 71 100 125 15 20 25 32 40 50 63 15 20 25 32 40 50 63 71 80 100 125 140
TOOLS

2
AZEZ6DAIST07XS2
930 x 300 x 454
• • • •
AZEZ6DAIST07S2 • • • •
3
AZEZ6DAIST07XS3
930 x 300 x 454
• • • •
AZEZ6DAIST07S3 • • • •
4
AZEZ6DAIST07S4 930 x 300 x 454 • • • •
Standard Ceiling
AZEZ6DAIST07M4 1,140 x 300 x 454 • • • • •
Void 5
AZEZ6DAIST07M5
1,425 x 300 x 454
• • • • •
AZEZ6DAIST07L5 • • • • • • •
• • • • •
TECHNICAL
DRAWINGS

AZEZ6DAIST07M6
6 1,638 x 300 x 454
AZEZ6DAIST07L6 • • • • • • •
7
AZEZ6DAIST07L7
1,425 x 515 x 454
• • • • • • •
AZEZ6DAIST07XL7 •
8
AZEZ6DAIST07L8
1,425 x 515 x 454
• • • • • • •
AZEZ6DAIST07XL8 •
Compact Ceiling 2 AZEZ6DAISL01S2 720 x 210 x 444 • • • • • •
Void 3 AZEZ6DAISL01S3 720 x 210 x 444 • • • • • •
4 AZEZ6DAISL01M4 930 x 210 x 444 • •
PREVIOUS

5 AZEZ6DAISL01L5 1,140 x 210 x 444 • • •


35
FDXM-F3 + RXM-M9 Split

Concealed ceiling unit rear


suction

Compact concealed ceiling unit, with a height of only


200mm

ʯʯ Invisible unit as the unit is concealed in the ceiling: only the


outblow
suction and discharge grilles are visible
ʯʯ Compact dimensions, can easily be mounted in a ceiling void of
only 240mm
FDXM-F3 bottom
suction

NEW
with auto
cleaning and
ʯʯ Medium external static pressure up to 40Pa facilitates unit use multi zoning
with flexible ducts of varying lengths option
ʯʯ Unified indoor unit range for R-32 and R-410A RXM20-35M9 BRC1H51W BRP069A81
NEW ʯʯ Auto cleaning filter option ensures maximum efficiency, comfort
and reliability by regular filter cleaning
NEW ʯʯ Multi zoning kit allows multiple individually-controlled climate
zones to be served by one indoor unit
ʯʯ Online controller (optional): control your indoor from any location
with an app, via your local network or internet and keep an
overview on your energy consumption
ʯʯ Low energy consumption thanks to DC fan motor

Efficiency data FDXM + RXM 25F3 + 25M9 35F3 + 35M9 50F3 + 50M9 60F3 + 60M9
Cooling capacity Nom. kW 2.40 3.40 5.00 6.00
Heating capacity Nom. kW 3.20 4.00 5.80 7.00
Power input Cooling Nom. kW 0.64 1.14 1.63 2.05
Heating Nom. kW 0.80 1.15 1.87 2.18
Seasonal efficiency Cooling Energy efficiency class A+ A A+ A
(according to Pdesign kW 2.40 3.40 5.00 6.00
EN14825) SEER 5.68 5.26 5.77 5.56
Annual energy consumption kWh 148 226 303 315
Heating (Average Energy efficiency class A+ A
climate) Pdesign kW 2.60 2.90 4.00 4.60
SCOP/A 4.24 3.88 3.93 3.80
Annual energy consumption kWh 858 1,046 1,424 1,693

Indoor unit FDXM 25F3 35F3 50F3 60F3


Dimensions Unit HeightxWidthxDepth mm 200x750x620 200x1,150x620
Weight Unit kg 21 28
Air filter Type Removable / washable
Fan Air flow rate Cooling Low/Medium/High m³/min 7.3/8.0/8.7 13.3/14.6/15.8 13.5/14.8/16.0
Heating Low/Medium/High m³/min 7.3/8.0/8.7 13.3/14.6/15.8 13.5/14.8/16.0
External static pressure Nom. Pa 30 40
Sound power level Cooling dBA 53 55 56
Heating dBA 53 55 56
Sound pressure level Cooling Low/High dBA 27/35 30/38
Heating Low/High dBA 27/35 30/38
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RXM 25M9 35M9 50M9 60M9


Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300
Weight Unit kg 32 47
Sound power level Cooling dBA 59 61 62 63
Heating dBA 59 61 62 63
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-32
GWP 675.0
Charge kg/TCO2Eq 0.76/0.52 1.40/0.95 1.45/0.98
Piping connections Liquid OD mm 6,35 6,4
Gas OD mm 9.50 12.7
Piping length OU - IU Max. m 20.0 30
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Current - 50Hz Maximum fuse amps (MFA) A 10 15

(1) EER/COP according to Eurovent 2012, for use outside EU only,


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter(earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

36
SKY AIR INTRO
FBA-A + RZAG-MV1/MY1

Concealed ceiling unit


with medium ESP

INDOOR
Slimmest yet most powerful medium static pressure unit

UNITS
outblow
on the market

ʯʯ Combination with Sky Air Alpha-series ensures best in class rear


suction
quality, highest efficiency and performace bottom
suction
ʯʯ Slimmest unit in class, only 245mm (300mm built-in height) and FBA-A
therefore narrow ceiling voids are no longer a challenge

OUTDOOR
UNITS
NEW
with
ʯʯ Low operation sound level down to 25dBA multi zoning
ʯʯ Medium external static pressure up to 150Pa facilitates using option
flexible ducts of varying lengths RZAG100-140MV1_MY1 BRC1H51W BRP069A81
ʯʯ Unified indoor unit can be combined with R-32 and R-410A

AIR CURTAINS
outdoor units, symplifying stock

BIDDLE
ʯʯ Combining with R-32 Bluevolution technology, reduces zones to be served by one indoor unit
environmental impact with 68% compared to R-410A, leads ʯʯ Reduced energy consumption thanks to specially developed DC
directly to lower energy consumption thanks to its high energy fan motor
efficiency and has up to lower 16% refrigerant charge ʯʯ Optional fresh air intake
NEW ʯʯ Possibility to change ESP via wired remote control allows ʯʯ Flexible installation: air suction direction can be altered from rear
optimisation of the supply air volume to bottom suction and choice between free use or connection to
ʯʯ Discretely concealed in the ceiling: only the suction and discharge optional suction grilles

VENTILATION
grilles are visible ʯʯ Standard built-in drain pump with 625mm lift increases flexibility
ʯʯ Multi zoning kit allows multiple individually-controlled climate and installation speed

Efficiency data FBA + RZAG 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 71A + 71MY1 100A + 100MY1 125A + 125MY1 140A + 140MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5
Seasonal efficiency Cooling Energy efficiency class A++ - A++ -
(according to Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4

CONTROL
SYSTEMS
EN14825) SEER 6.22 6.47 6.19 6.42 6.22 6.47 6.19 6.42
Annual energy consumption kWh 382 514 1,173 1,252 382 514 1,173 1,252
Heating (Average Energy efficiency class A+ - A+ -
climate) Pdesign kW 4.70 7.80 9.52 4.70 7.80 9.52
SCOP/A 4.20 4.36 4.12 4.11 4.20 4.36 4.12 4.11
Annual energy consumption kWh 1,566 2,505 3,235 3,243 1,566 2,505 3,235 3,243

Indoor unit FBA 71A 100A 125A 71A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800 245x1,000x800 245x1,400x800

& ACCESSORIES
Weight Unit kg 35.0 46.0 35.0 46.0

OPTIONS
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0
Heating Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0
External static pressure Nom./High Pa 30/150 40/150 50/150 30/150 40/150 50/150
Sound power level Cooling dBA 56 58 62 56 58 62
Sound pressure level Cooling Low/High dBA 25.0/30.0 30.0/34.0 32.0/37.0 25.0/30.0 30.0/34.0 32.0/37.0
Heating Low/High dBA 25.0/31.0 30.0/36.0 32.0/38.0 25.0/31.0 30.0/36.0 32.0/38.0
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
& PLATFORMS

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220


TOOLS

Outdoor unit RZAG 71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1
Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 70 92 70 92
Sound power level Cooling dBA 64 66 69 70 65 66 69 70
Sound pressure level Cooling Nom. dBA 46 47 50 51 46 47 50 51
Heating Nom. dBA 49 51 52 49 51 52
Operation range Cooling Ambient Min.~Max. °CDB -20~52
Heating Ambient Min.~Max. °CWB -20~18.0
Refrigerant Type/GWP R-32/675
TECHNICAL
DRAWINGS

Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.95/1.99 3.75/2.53


Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 55 85 55 85
length System Equivalent m 75 100 75 100
Chargeless m 40
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16
PREVIOUS

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

37
FBA-A + RZASG-MV1/MY1

Concealed ceiling unit


with medium ESP
Slimmest yet most powerful medium static pressure unit
on the market outblow

ʯʯ Combination with Sky Air Advance-series ensures good value for


money for all types of commercial applications rear
suction
ʯʯ Slimmest unit in class, only 245mm (300mm built-in height) bottom
ʯʯ Low operation sound level down to 25dBA FBA-A
suction
ʯʯ Medium external static pressure up to 150Pa facilitates using
flexible ducts of varying lengths
ʯʯ Unified indoor unit can be combined with R-32 and R-410A
outdoor units, symplifying stock
ʯʯ Combining with R-32 Bluevolution technology, reduces NEW
environmental impact with 68% compared to R-410A with
ʯʯ Possibility to change ESP via wired remote control allows multi zoning
optimisation of the supply air volume
ʯʯ Discretely concealed in the ceiling: only the suction and discharge option
grilles are visible RZASG100-140MV1_MY1 BRC1H51W BRP069A81
NEW ʯʯ Multi zoning kit allows multiple individually-controlled climate
zones to be served by one indoor unit
External static pressure (Pa)

Optimised supply air volume Air flow (rated)


Fan characteristic
Automatically selects the most appropriate fan curve to achieve the units’ nominal air flow within ±10% curves

Why? Air flow (actual)

After installation the real ducting will frequently differ from the initially calculated air flow resistance
 the real air flow may be much lower or higher than nominal, leading to a lack of capacity or
uncomfortable air temperature
Air flow (with
Duct resistance
automatic adjustment)
Automatic Airflow Adjustment function will adapt the unit’s fan speed to any ducting automatically curves
(10 or more fan curves are ­available on every model), making installation much faster

±10% Air flow (m3/min)

Efficiency data FBA + RZASG 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 100A + 100MY1 125A + 125MY1 140A + 140MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Seasonal efficiency Cooling Energy efficiency class A++ A+ - A+ -
(according to Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
EN14825) SEER 6.19 5.83 5.47 5.81 5.83 5.47 5.81
Annual energy consumption kWh 385 570 1,378 1,384 570 1,378 1,384
Heating (Average Energy efficiency class A+ A - A -
climate) Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 4.01 3.85 3.63 3.85 3.63 3.85
Annual energy consumption kWh 1,571 2,182 2,314 2,836 2,182 2,314 2,836

Indoor unit FBA 71A 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800
Weight Unit kg 35.0 46.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 23.0/26.0/29.0 23.5/29.0/34.0
Heating Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 23.0/26.0/29.0 23.5/29.0/34.0
External static pressure Nom./High Pa 30/150 40/150 50/150 40/150 50/150
Sound power level Cooling dBA 56 58 62 58 62
Sound pressure level Cooling Low/High dBA 25.0/30.0 30.0/34.0 32.0/37.0 30.0/34.0 32.0/37.0
Heating Low/High dBA 25.0/31.0 30.0/36.0 32.0/38.0 30.0/36.0 32.0/38.0
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RZASG 71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 78 70 77
Sound power level Cooling dBA 65 70 71 73 70 71 73
Sound pressure level Cooling Nom. dBA 46 53 54 53 54
Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16 20 16

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

38
SKY AIR INTRO
FBA-A + AZAS-MV1/MY1

Concealed ceiling unit


with medium ESP

INDOOR
Slimmest yet most powerful medium static pressure unit

UNITS
outblow
on the market

ʯʯ Ideal solution for small businesses and shops rear


suction
ʯʯ Slimmest unit in class, only 245mm (300mm built-in height) bottom
suction
ʯʯ Low operation sound level down to 25dBA FBA-A
ʯʯ Medium external static pressure up to 150Pa facilitates using
flexible ducts of varying lengths

OUTDOOR
UNITS
ʯʯ Unified indoor unit can be combined with R-32 and R-410A
outdoor units, symplifying stock
NEW
ʯʯ Combining with R-32 Bluevolution technology, reduces
with
environmental impact with 68% compared to R-410A multi zoning
ʯʯ Possibility to change ESP via wired remote control allows option
optimisation of the supply air volume AZAS71MV1 BRC1H51W BRP069A81
ʯʯ Discretely concealed in the ceiling: only the suction and discharge

AIR CURTAINS
grilles are visible

BIDDLE
NEW ʯʯ Multi zoning kit allows multiple individually-controlled climate
zones to be served by one indoor unit

VENTILATION
Efficiency data FBA + AZAS 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 100A + 100MY1 125A + 125MY1 140A + 140MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Seasonal efficiency Cooling Energy efficiency class A - A -
(according to Pdesign kW 6.80 9.50 12.1 13.0 9.50 12.1 13.0

CONTROL
SYSTEMS
EN14825) SEER 5.57 5.25 4.85 5.50 5.25 4.85 5.50
Annual energy consumption kWh 427 633 1,497 1,418 633 1,497 1,418
Heating (Average Energy efficiency class A - A -
climate) Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 3.81 3.55 3.85 3.81 3.55 3.85
Annual energy consumption kWh 1,654 2,205 2,366 2,836 2,205 2,366 2,836

Indoor unit FBA 71A 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800

& ACCESSORIES
Weight Unit kg 35.0 46.0

OPTIONS
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 23.0/26.0/29.0 23.5/29.0/34.0
Heating Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 23.0/26.0/29.0 23.5/29.0/34.0
External static pressure Nom./High Pa 30/150 40/150 50/150 40/150 50/150
Sound power level Cooling dBA 56 58 62 58 62
Sound pressure level Cooling Low/High dBA 25.0/30.0 30.0/34.0 32.0/37.0 30.0/34.0 32.0/37.0
Heating Low/High dBA 25.0/31.0 30.0/36.0 32.0/38.0 30.0/36.0 32.0/38.0
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
& PLATFORMS

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220


TOOLS

Outdoor unit AZAS 71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 78 70 77
Sound power level Cooling dBA 65 70 71 73 70 71 73
Sound pressure level Cooling Nom. dBA 46 53 54 53 54
Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -5~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
TECHNICAL
DRAWINGS

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96


Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 30
length System Equivalent m 50
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16 20
PREVIOUS

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

39
FBA-A + RXM-M9 Split

Concealed ceiling unit


with medium ESP
Slimmest yet most powerful medium static pressure unit
on the market
outblow

ʯʯ Combination with split outdoor units is ideal for small retail,


offices or residential applications
rear
ʯʯ Slimmest unit in class, only 245mm (300mm built-in height) suction
ʯʯ Low operation sound level down to 25dBA bottom
suction
ʯʯ Medium external static pressure up to 150Pa facilitates using FBA-A
flexible ducts of varying lengths
ʯʯ Unified indoor unit can be combined with R-32 and R-410A
outdoor units, symplifying stock
ʯʯ Combining with R-32 Bluevolution technology, reduces NEW
environmental impact with 68% compared to R-410A with
ʯʯ Possibility to change ESP via wired remote control allows
optimisation of the supply air volume multi zoning
ʯʯ Discretely concealed in the ceiling: only the suction and discharge option
grilles are visible
RXM20-35M9 BRC1H51W BRP069A81
NEW ʯʯ Multi zoning kit allows multiple individually-controlled climate
zones to be served by one indoor unit
External static pressure (Pa)

Optimised supply air volume Air flow (rated)


Fan characteristic
Automatically selects the most appropriate fan curve to achieve the units’ nominal air flow within ±10% curves

Why? Air flow (actual)

After installation the real ducting will frequently differ from the initially calculated air flow resistance
 the real air flow may be much lower or higher than nominal, leading to a lack of capacity or
uncomfortable air temperature
Air flow (with
Duct resistance
automatic adjustment)
Automatic Airflow Adjustment function will adapt the unit’s fan speed to any ducting automatically curves
(10 or more fan curves are ­available on every model), making installation much faster

±10% Air flow (m3/min)

Efficiency data FBA + RXM 35A + 35M9 50A + 50M9 60A + 60M9
Cooling capacity Nom. kW 3.40 5.00 5.70
Heating capacity Nom. kW 4.00 5.50 7.00
Power input Cooling Nom. kW 0.85 1.41 1.64
Heating Nom. kW 1.00 1.44 1.89
Seasonal efficiency Cooling Energy efficiency class A++ A+
(according to Pdesign kW 3.40 5.00 5.70
EN14825) SEER 6.23 6.27 5.91
Annual energy consumption kWh 191 279 337
Heating (Average Energy efficiency class A+
climate) Pdesign kW 2.90 4.40 4.60
SCOP/A 4.07 4.06 4.01
Annual energy consumption kWh 996 1,517 1,607

Indoor unit FBA 35A 50A 60A


Dimensions Unit HeightxWidthxDepth mm 245x700x800 245x1,000x800
Weight Unit kg 28.0 35.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 10.5/12.5/15.0 12.5/15.0/18.0
Heating Low/Medium/High m³/min 10.5/12.5/15.0 12.5/15.0/18.0
External static pressure Nom./High Pa 30/150
Sound power level Cooling dBA 60 56
Sound pressure level Cooling Low/High dBA 29.0/35.0 25.0/30.0
Heating Low/High dBA 29.0/37.0 25.0/31.0
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RXM 35M9 50M9 60M9


Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300
Weight Unit kg 32 47
Sound power level Cooling dBA 61 62 63
Heating dBA 61 62 63
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-32
GWP 675.0
Charge kg/TCO2Eq 0.76/0.52 1.40/0.95 1.45/0.98
Piping connections Liquid OD mm 6,35 6,4
Gas OD mm 9.50 12.7
Piping length OU - IU Max. m 20.0 30
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Current - 50Hz Maximum fuse amps (MFA) A 10 15

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

40
SKY AIR INTRO
FDA-A + RZAG-MV1/MY1, RZASG-MV1/MY1

Concealed ceiling unit


with high ESP

INDOOR
ESP up to 200, ideal for large sized spaces

UNITS
outblow

ʯʯ Unified range for R-32 and R-410A simplifying stock


ʯʯ High external static pressure up to 200Pa facilitates extensive duct rear
suction
and grille network bottom
suction
ʯʯ Possibility to change ESP via wired remote control allows FDA-A
optimisation of the supply air volume
ʯʯ Discretely concealed in the ceiling: only the suction and discharge

OUTDOOR
UNITS
grilles are visible
ʯʯ Reduced energy consumption thanks to specially developed DC
fan motor
ʯʯ No optional adapter needed for DIII-connection, link your unit into
the wider building management system.
ʯʯ Flexible installation, as the air suction direction can be altered RZAG100-140MV1/MY1 BRC1H51W BRP069A81
from rear to bottom suction

AIR CURTAINS
ʯʯ Standard built-in drain pump with 625mm lift increases flexibility

BIDDLE
and installation speed

VENTILATION
Sky Air Alpha-series Sky Air Advance-series
Efficiency data FDA + RZAG/RZASG 125A + 125MV1 125A + 125MY1 125A + 125MV1 125A + 125MY1
Cooling capacity Nom. kW 12.1
Heating capacity Nom. kW 13.5
Seasonal efficiency Cooling Energy efficiency class - - - -
(according to Pdesign kW 12.1

CONTROL
SYSTEMS
EN14825) SEER 6.59 5.03
Annual energy consumption kWh 1,102 1,444
Heating (Average Energy efficiency class - - - -
climate) Pdesign kW 9.52 6.00
SCOP/A 4.08 3.58
Annual energy consumption kWh 3,267 2,346

Indoor unit FDA 125A


Dimensions Unit HeightxWidthxDepth mm 300x1,400x700

& ACCESSORIES
Required ceiling void > mm 350
Weight Unit kg 45

OPTIONS
Decoration panel Model BYBS125DJW1
Colour White (10Y9/0.5)
Dimensions HeightxWidthxDepth mm 55x1,500x500
Weight kg 6.5
Air filter Type Resin net with mold resistance
Fan - Air flow rate Cooling High/Low m³/min 39/28
Heating High/Low m³/min 39/28
Fan - External static pressure High/Nom./Maximum available/High Pa 200/50/-
Sound power level Cooling dBA 66
Sound pressure level Cooling High/Low dBA 40/33
& PLATFORMS

Heating High/Low dBA 40/33


TOOLS

Refrigerant Type R-32 / R-410A


Control systems Infrared remote control BRC4C65
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

Outdoor unit RZAG/RZASG 125MV1 125MY1 125MV1 125MY1


Dimensions Unit HeightxWidthxDepth mm 1,430x940x320 1,430x940x320 990x940x320 990x940x320
Weight Unit kg 92 92 70 70
Sound power level Cooling dBA 69 69 71 71
Sound pressure level Cooling Nom. dBA 50 50 53 53
TECHNICAL
DRAWINGS

Heating Nom. dBA 52 52 57 57


Operation range Cooling Ambient Min.~Max. °CDB -20~52 -15~46
Heating Ambient Min.~Max. °CWB -20~18 -15~15,5
Refrigerant Type R-32
Charge kg 3,75 2,6
TCO₂eq 2,53 1,76
GWP 675
Piping connections Piping length OU - IU Max. m 85 50
System Chargeless m 40 30
Power supply Phase / Frequency / Voltage Hz / V 1~/50/220-240 3N~/50 / 380-415 1~/50/220-240 3N~/50 / 380-415
PREVIOUS

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.
41
FAA-A + RZAG-MV1/MY1

Wall mounted unit


For rooms with no false ceilings nor free floor space

ʯʯ Combination with Sky Air Alpha-series ensures best in class


quality, highest efficiency and performance
ʯʯ Flat, stylish front panel blends easily within any interior décor and
is easier to clean
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified indoor unit range for R-32 and R-410A FAA-A
ʯʯ Combining with R-32 Bluevolution technology, reduces
environmental impact with 68% compared to R-410A, leads
directly to lower energy consumption thanks to its high energy
efficiency and has up to lower 16% refrigerant charge
ʯʯ Reduced energy consumption thanks to specially developed DC
fan motor
ʯʯ The air is comfortably spread up- and downwards thanks to
5 different discharge angles that can be programmed via the RZAG100-140MV1_MY1 BRC1H51W BRP069A81
remote control
ʯʯ Maintenance operations can be performed easily from the front of
the unit
ʯʯ Flexible to install as the largest casing only weighs 17kg and piping
connection can be done at the bottom, left or right of the unit

Efficiency data FAA + RZAG 71A + 71MV1 100A + 100MV1 71A + 71MY1 100A + 100MY1
Cooling capacity Nom. kW 6.80 9.50 6.80 9.50
Heating capacity Nom. kW 7.50 10.8 7.50 10.8
Seasonal efficiency Cooling Energy efficiency class A++
(according to Pdesign kW 6.80 9.50 6.80 9.50
EN14825) SEER 6.58 6.42 6.58 6.42
Annual energy consumption kWh 362 518 362 518
Heating (Average Energy efficiency class A+
climate) Pdesign kW 4.70 7.80 4.70 7.80
SCOP/A 4.02 4.01 4.02 4.01
Annual energy consumption kWh 1,637 2,723 1,637 2,723

Indoor unit FAA 71A 100A 71A 100A


Dimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240 290x1,050x238 340x1,200x240
Weight Unit kg 13.0 17.0 13.0 17.0
Air filter Type -
Fan Air flow rate Cooling Low/Medium/High m³/min 14.0/16/18.0 19.0/23/26.0 14.0/16/18.0 19.0/23/26.0
Heating Low/Medium/High m³/min 14.0/16.0/18.0 19.0/23.0/26.0 14.0/16.0/18.0 19.0/23.0/26.0
Sound power level Cooling dBA 61 65 61 65
Heating dBA 61 65 61 65
Sound pressure level Cooling Low/High dBA 40/45 41/49 40/45 41/49
Heating Low/High dBA 40/45 41/49 40/45 41/49
Control systems Infrared remote control BRC7EB518
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RZAG 71MV1 100MV1 71MY1 100MY1


Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 70 92 70 92
Sound power level Cooling dBA 64 66 65 66
Sound pressure level Cooling Nom. dBA 46 47 46 47
Heating Nom. dBA 49 51 49 51
Operation range Cooling Ambient Min.~Max. °CDB -20~52
Heating Ambient Min.~Max. °CWB -20~18
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.95/1.99 3.75/2.53
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 55 85 55 85
length System Equivalent m 75 100 75 100
Chargeless m 40
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

42
SKY AIR INTRO
FAA-A + RZASG-MV1/MY1

Wall mounted unit


For rooms with no false ceilings nor free floor space

INDOOR
UNITS
ʯʯ Combination with Sky Air Advance-series ensures good value for
money for all types of commercial applications
ʯʯ Flat, stylish front panel blends easily within any interior décor and
is easier to clean
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified indoor unit range for R-32 and R-410A FAA-A
ʯʯ Combining with R-32 Bluevolution technology, reduces
environmental impact with 68% compared to R-410A, leads

OUTDOOR
UNITS
directly to lower energy consumption thanks to its high energy
efficiency and has up to lower 16% refrigerant charge

RZASG100-140MV1_MY1 BRC1H51W BRP069A81

AIR CURTAINS
BIDDLE
VENTILATION
Efficiency data FAA + RZASG 71A + 71MV1 100A + 100MV1 100A + 100MY1
Cooling capacity Nom. kW 6.80 9.50
Heating capacity Nom. kW 7.50 10.8
Seasonal efficiency Cooling Energy efficiency class A++ A+
(according to Pdesign kW 6.80 9.50

CONTROL
SYSTEMS
EN14825) SEER 6.41 5.83
Annual energy consumption kWh 371 570
Heating (Average Energy efficiency class A
climate) Pdesign kW 4.50 6.00
SCOP/A 3.90 3.85
Annual energy consumption kWh 1,615 2,182

Indoor unit FAA 71A 100A 100A


Dimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240

& ACCESSORIES
Weight Unit kg 13.0 17.0

OPTIONS
Air filter Type -
Fan Air flow rate Cooling Low/Medium/High m³/min 14.0/16/18.0 19.0/23/26.0
Heating Low/Medium/High m³/min 14.0/16.0/18.0 19.0/23.0/26.0
Sound power level Cooling dBA 61 65
Heating dBA 61 65
Sound pressure level Cooling Low/High dBA 40/45 41/49
Heating Low/High dBA 40/45 41/49
Control systems Infrared remote control BRC7EB518
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
& PLATFORMS

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240


TOOLS

Outdoor unit RZASG 71MV1 100MV1 100MY1


Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70
Sound power level Cooling dBA 65 70
Sound pressure level Cooling Nom. dBA 46 53
Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -15~46
Heating Ambient Min.~Max. °CWB -15~15,5
Refrigerant Type/GWP R-32/675
TECHNICAL
DRAWINGS

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76


Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 16
PREVIOUS

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

43
FAA-A + AZAS-MV1/MY1

Wall mounted unit


For rooms with no false ceilings nor free floor space

ʯʯ Ideal solution for small businesses and shops


ʯʯ Flat, stylish front panel blends easily within any interior décor and
is easier to clean
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Combining with R-32 Bluevolution technology, reduces FAA-A
environmental impact with 68% compared to R-410A, leads
directly to lower energy consumption thanks to its high energy
efficiency and has up to lower 16% refrigerant charge

AZAS71MV1 BRC1H51W BRP069A81

Efficiency data FAA + AZAS 71A + 71MV1 100A + 100MV1 100A + 100MY1
Cooling capacity Nom. kW 6.80 9.50
Heating capacity Nom. kW 7.50 10.8
Seasonal efficiency Cooling Energy efficiency class A+ A
(according to Pdesign kW 6.80 9.50
EN14825) SEER 5.77 5.25
Annual energy consumption kWh 412 633
Heating (Average Energy efficiency class A
climate) Pdesign kW 4.50 6.00
SCOP/A 3.81
Annual energy consumption kWh 1,654 2,205

Indoor unit FAA 71A 100A 100A


Dimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240
Weight Unit kg 13.0 17.0
Air filter Type -
Fan Air flow rate Cooling Low/Medium/High m³/min 14.0/16/18.0 19.0/23/26.0
Heating Low/Medium/High m³/min 14.0/16.0/18.0 19.0/23.0/26.0
Sound power level Cooling dBA 61 65
Heating dBA 61 65
Sound pressure level Cooling Low/High dBA 40/45 41/49
Heating Low/High dBA 40/45 41/49
Control systems Infrared remote control BRC7EB518
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit AZAS 71MV1 100MV1 100MY1


Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70
Sound power level Cooling dBA 65 70
Sound pressure level Cooling Nom. dBA 46 53
Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -5~46
Heating Ambient Min.~Max. °CWB -15~15,5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 30
length System Equivalent m 50
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 16

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

44
45
TECHNICAL TOOLS OPTIONS CONTROL BIDDLE OUTDOOR INDOOR
PREVIOUS VENTILATION SKY AIR INTRO
DRAWINGS & PLATFORMS & ACCESSORIES SYSTEMS AIR CURTAINS UNITS UNITS
FHA-A + RZAG-MV1/MY1

Ceiling suspended unit


For wide rooms with no false ceilings nor free floor space

ʯʯ Combination with Sky Air Alpha-series ensures best in class


quality, highest efficiency and performance
ʯʯ Ideal for comfortable air flow in wide rooms thanks to Coanda
effect: up to 100° discharge angle

FHA-A

ʯʯ Even rooms with ceilings up to 3.8m can be heated up or cooled


down very easily without capacity loss
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Combining with R-32 Bluevolution technology, reduces RZAG100-140MV1_MY1 BRC1H51W BRP069A81
environmental impact with 68% compared to R-410A, leads
directly to lower energy consumption thanks to its high energy
efficiency and has up to lower 16% refrigerant charge
ʯʯ Can easily be mounted in corners and narrow spaces, as it only ʯʯ Reduced energy consumption thanks to specially developed small
needs 30mm lateral service space tube heat exchanger, DC fan motor and drain pump
ʯʯ 5 different fan speeds available for maximum comfort
Air outlet
ʯʯ Stylish unit blends easily with any interior. The flaps close entirely
Air inlet when the unit is not operating and there are no air intake grilles
30 or more 30 or more
(Service space) (Service space) Obstruction visible

Efficiency data FHA + RZAG 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 71A + 71MY1 100A + 100MY1 125A + 125MY1 140A + 140MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5
Seasonal efficiency Cooling Energy efficiency class A++ - A++ -
(according to Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
EN14825) SEER 7.11 6.42 8.22 6.42 7.11 6.42 8.22 6.42
Annual energy consumption kWh 335 518 883 1,252 335 518 883 1,252
Heating (Average Energy efficiency class A+ A++ - A+ A++ -
climate) Pdesign kW 4.70 7.80 9.52 4.70 7.80 9.52
SCOP/A 4.32 4.61 4.09 4.30 4.32 4.61 4.09 4.30
Annual energy consumption kWh 1,523 2,369 3,259 3,100 1,523 2,369 3,259 3,100

Indoor unit FHA 71A 100A 125A 71A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690 235x1,270x690 235x1,590x690
Weight Unit kg 32.0 38.0 32.0 38.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
Heating Low/Medium/High m³/min 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
Sound power level Cooling dBA 55 60 62 64 55 60 62 64
Sound pressure level Cooling Low/High dBA 34/38 34/42 37/44 38/46 34/38 34/42 37/44 38/46
Heating Nom./High dBA 36/38 38/42 41/44 42/46 36/38 38/42 41/44 42/46
Control systems Infrared remote control BRC7GA53 / BRC7GA56
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RZAG 71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1
Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 70 92 70 92
Sound power level Cooling dBA 64 66 69 70 65 66 69 70
Sound pressure level Cooling Nom. dBA 46 47 50 51 46 47 50 51
Heating Nom. dBA 49 51 52 49 51 52
Operation range Cooling Ambient Min.~Max. °CDB -20~52
Heating Ambient Min.~Max. °CWB -20~18
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.95/1.99 3.75/2.53
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 55 85 55 85
length System Equivalent m 75 100 75 100
Chargeless m 40
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

46
SKY AIR INTRO
FHA-A + RZASG-MV1/MY1

Ceiling suspended unit


For wide rooms with no false ceilings nor free floor space

INDOOR
UNITS
ʯʯ Combination with Sky Air Advance-series ensures good value for
money for all types of commercial applications
ʯʯ Ideal for comfortable air flow in wide rooms thanks to Coanda
effect: up to 100° discharge angle
ʯʯ Even rooms with ceilings up to 3.8m can be heated up or cooled
down very easily without capacity loss FHA-A
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified indoor unit range for R-32 and R-410A

OUTDOOR
UNITS
ʯʯ Combining with R-32 Bluevolution technology, reduces
environmental impact with 68% compared to R-410A, leads
directly to lower energy consumption thanks to its high energy
efficiency and has up to lower 16% refrigerant charge

RZASG100-140MV1_MY1 BRC1H51W BRP069A81

AIR CURTAINS
BIDDLE
VENTILATION
Efficiency data FHA + RZASG 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 100A + 100MY1 125A + 125MY1 140A + 140MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Seasonal efficiency Cooling Energy efficiency class A+ - A+ -

CONTROL
(according to

SYSTEMS
Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
EN14825) SEER 5.95 5.83 5.83 5.88 5.83 5.83 5.88
Annual energy consumption kWh 400 570 1,297 1,368 570 1,297 1,368
Heating (Average Energy efficiency class A - A -
climate) Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 3.90 3.91 3.83 3.81 3.91 3.83 3.81
Annual energy consumption kWh 1,616 2,148 2,193 2,866 2,148 2,193 2,866

Indoor unit FHA 71A 100A 125A 140A 100A 125A 140A

& ACCESSORIES
Dimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690

OPTIONS
Weight Unit kg 32.0 38.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
Heating Low/Medium/High m³/min 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
Sound power level Cooling dBA 55 60 62 64 60 62 64
Sound pressure level Cooling Low/High dBA 34/38 34/42 37/44 38/46 34/42 37/44 38/46
Heating Nom./High dBA 36/38 38/42 41/44 42/46 38/42 41/44 42/46
Control systems Infrared remote control BRC7GA53 / BRC7GA56
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
& PLATFORMS
TOOLS

Outdoor unit RZASG 71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 78 70 77
Sound power level Cooling dBA 65 70 71 73 70 71 73
Sound pressure level Cooling Nom. dBA 46 53 54 53 54
Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
TECHNICAL
DRAWINGS

Piping connections Liquid/Gas mm 9.52/15.9


Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16
PREVIOUS

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

47
FHA-A + RXM-M9 Split

Ceiling suspended unit


For wide rooms with no false ceilings nor free floor space

ʯʯ Combination with split outdoor units is ideal for small retail,


offices or residential applications
ʯʯ Ideal for comfortable air flow in wide rooms thanks to Coanda
effect: up to 100° discharge angle
ʯʯ Even rooms with ceilings up to 3.8m can be heated up or cooled
down very easily without capacity loss FHA-A
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Combining with R-32 Bluevolution technology, reduces
environmental impact with 68% compared to R-410A, leads
directly to lower energy consumption thanks to its high energy
efficiency and has up to lower 16% refrigerant charge

RXM20-35M9 BRC1H51W BRP069A81

Efficiency data FHA + RXM 35A + 35M9 50A + 50M9 60A + 60M9
Cooling capacity Nom. kW 3.40 5.00 5.70
Heating capacity Nom. kW 4.00 6.00 7.20
Power input Cooling Nom. kW 0.91 1.56 1.73
Heating Nom. kW 0.98 1.79 2.17
Seasonal efficiency Cooling Energy efficiency class A++ A+
(according to Pdesign kW 3.40 5.00 5.70
EN14825) SEER 6.24 5.92 6.08
Annual energy consumption kWh 191 295 328
Heating (Average Energy efficiency class A+ A
climate) Pdesign kW 3.10 4.35 4.71
SCOP/A 4.43 3.86 3.87
Annual energy consumption kWh 979 1,578 1,704

Indoor unit FHA 35A 50A 60A


Dimensions Unit HeightxWidthxDepth mm 235x960x690 235x1,270x690
Weight Unit kg 24.0 25.0 31.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 10.0/11.5/14.0 10.0/12.0/15.0 11.5/15.0/19.5
Heating Low/Medium/High m³/min 10.0/11.5/14.0 10.0/12.0/15.0 11.5/15.0/19.5
Sound power level Cooling dBA 53 54
Sound pressure level Cooling Low/High dBA 31/36 32/37 33/37
Heating Nom./High dBA 34/36 35/37
Control systems Infrared remote control BRC7GA53 / BRC7GA56
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RXM 35M9 50M9 60M9


Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300
Weight Unit kg 32 47
Sound power level Cooling dBA 61 62 63
Heating dBA 61 62 63
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-32
GWP 675.0
Charge kg/TCO2Eq 0.76/0.52 1.40/0.95 1.45/0.98
Piping connections Liquid OD mm 6,35 6,4
Gas OD mm 9.50 12.7
Piping length OU - IU Max. m 20.0 30
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Current - 50Hz Maximum fuse amps (MFA) A 10 15

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

48
49
TECHNICAL TOOLS OPTIONS CONTROL BIDDLE OUTDOOR INDOOR
PREVIOUS VENTILATION SKY AIR INTRO
DRAWINGS & PLATFORMS & ACCESSORIES SYSTEMS AIR CURTAINS UNITS UNITS
FUA-A + RZAG-MV1/MY1
UNIQUE

4-way blow
ceiling suspended unit
Unique Daikin unit for high rooms with no false ceilings
nor free floor space

ʯʯ Combination with Sky Air Alpha-series ensures best in class


quality, highest efficiency and performance
ʯʯ Even rooms with ceilings up to 3.5m can be heated up or cooled FUA-A
down very easily without capacity loss
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Combining with R-32 Bluevolution technology, reduces
environmental impact with 68% compared to R-410A, leads
directly to lower energy consumption thanks to its high energy
efficiency and has up to lower 16% refrigerant charge
ʯʯ Individual flap control: flexibility to suit every room layout without RZAG100-140MV1_MY1 BRC1H51W BRP069A81
changing the location of the unit!
ʯʯ Stylish modern casing finished in pure white (RAL9010) and iron
grey (RAL7011) blends easily with any interior
ʯʯ Optimum comfort guaranteed with automatic air flow adjustment ʯʯ Standard drain pump with 500mm lift increases flexibility
to the required load and installation speed
ʯʯ 5 different discharge angles between 0 and 60°can be
programmed via the remote control

0° to 60°

Efficiency data FUA + RZAG 71A + 71MV1 100A + 100MV1 125A + 125MV1 71A + 71MY1 100A + 100MY1 125A + 125MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 6.80 9.50 12.1
Heating capacity Nom. kW 7.50 10.8 13.5 7.50 10.8 13.5
Seasonal efficiency Cooling Energy efficiency class A++ - A++ -
(according to Pdesign kW 6.80 9.50 12.1 6.80 9.50 12.1
EN14825) SEER 7.02 6.42 6.39 7.02 6.42 6.39
Annual energy consumption kWh 339 518 1,136 339 518 1,136
Heating (Average Energy efficiency class A+ - A+ -
climate) Pdesign kW 4.70 7.80 9.52 4.70 7.80 9.52
SCOP/A 4.20 4.50 4.26 4.20 4.50 4.26
Annual energy consumption kWh 1,567 2,427 3,129 1,567 2,427 3,129

Indoor unit FUA 71A 100A 125A 71A 100A 125A


Dimensions Unit HeightxWidthxDepth mm 198x950x950
Weight Unit kg 25.0 26.0 25.0 26.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5
Heating Low/Medium/High m³/min 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5
Sound power level Cooling dBA 59 64 65 59 64 65
Heating dBA 59 64 65 59 64 65
Sound pressure level Cooling Low/High dBA 35/41 39/46 40/47 35/41 39/46 40/47
Heating Low/High dBA 35/41 39/46 40/47 35/41 39/46 40/47
Control systems Infrared remote control BRC7EB518
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V -/-/-

Outdoor unit RZAG 71MV1 100MV1 125MV1 71MY1 100MY1 125MY1


Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 70 92 70 92
Sound power level Cooling dBA 64 66 69 65 66 69
Sound pressure level Cooling Nom. dBA 46 47 50 46 47 50
Heating Nom. dBA 49 51 52 49 51 52
Operation range Cooling Ambient Min.~Max. °CDB -20~52
Heating Ambient Min.~Max. °CWB -20~18.0
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.95/1.99 3.75/2.53
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 55 85 55 85
length System Equivalent m 75 100 75 100
Chargeless m 40
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

50
SKY AIR INTRO
FUA-A + RZASG-MV1/MY1
UNIQUE

4-way blow
ceiling suspended unit

INDOOR
Unique Daikin unit for high rooms with no false ceilings

UNITS
nor free floor space

ʯʯ Combination with Sky Air Advance-series ensures good value for


money for all types of commercial applications
ʯʯ Even rooms with ceilings up to 3.5m can be heated up or cooled FUA-A
down very easily without capacity loss
ʯʯ Can easily be installed in both new and refurbishment projects

OUTDOOR
UNITS
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Combining with R-32 Bluevolution technology, reduces
environmental impact with 68% compared to R-410A, leads
directly to lower energy consumption thanks to its high energy
efficiency and has up to lower 16% refrigerant charge
ʯʯ Individual flap control: flexibility to suit every room layout without RZASG100-140MV1_MY1 BRC1H51W BRP069A81
changing the location of the unit!

AIR CURTAINS
ʯʯ Stylish modern casing finished in pure white (RAL9010) and iron

BIDDLE
grey (RAL7011) blends easily with any interior

VENTILATION
Efficiency data FUA + RZASG 71A + 71MV1 100A + 100MV1 125A + 125MV1 100A + 100MY1 125A + 125MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 9.50 12.1
Heating capacity Nom. kW 7.50 10.8 13.5 10.8 13.5
Seasonal efficiency Cooling Energy efficiency class A++ A+ - A+ -
(according to Pdesign kW 6.80 9.50 12.1 9.50 12.1

CONTROL
SYSTEMS
EN14825) SEER 6.16 5.83 5.49 5.83 5.49
Annual energy consumption kWh 386 570 1,378 570 1,378
Heating (Average Energy efficiency class A A+ - A+ -
climate) Pdesign kW 4.50 6.00
SCOP/A 3.90 4.01 3.84 4.01 3.84
Annual energy consumption kWh 1,615 2,095 2,188 2,095 2,188

Indoor unit FUA 71A 100A 125A 100A 125A


Dimensions Unit HeightxWidthxDepth mm 198x950x950

& ACCESSORIES
Weight Unit kg 25.0 26.0

OPTIONS
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 20.0/25.5/31.0 20.5/26.5/32.5
Heating Low/Medium/High m³/min 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 20.0/25.5/31.0 20.5/26.5/32.5
Sound power level Cooling dBA 59 64 65 64 65
Heating dBA 59 64 65 64 65
Sound pressure level Cooling Low/High dBA 35/41 39/46 40/47 39/46 40/47
Heating Low/High dBA 35/41 39/46 40/47 39/46 40/47
Control systems Infrared remote control BRC7EB518
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
& PLATFORMS

Power supply Phase/Frequency/Voltage Hz/V -/-/-


TOOLS

Outdoor unit RZASG 71MV1 100MV1 125MV1 100MY1 125MY1


Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70
Sound power level Cooling dBA 65 70 71 70 71
Sound pressure level Cooling Nom. dBA 46 53
Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
TECHNICAL
DRAWINGS

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76


Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16
PREVIOUS

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

51
FVA-A + RZAG-MV1/MY1

Floor standing unit


For commercial spaces with high ceilings

Combination with Sky Air Alpha-series ensures best in class quality,


highest efficiency and performance

ʯʯ Unified indoor unit range for R-32 and R-410A


ʯʯ Ideal solution for commercial and busy environments
ʯʯ Decrease of temperature variation by automatic fan speed FVA71A
selection or freely selectable 3-step fan speed.
ʯʯ Improved comfort as a result of better airflow distribution from
the vertical out blow which allows manual adjustment of air outlet
blades at the top of the unit.
ʯʯ Selectable horizontal out blow to better suit the layout of the
room (via wired remote controller BRC1E*)
ʯʯ No optional adapter needed for DIII-connection, link your unit into
the wider building management system. RZAG100-140MV1_MY1 BRC1H51W BRP069A81

Side view blades air outlet

All up Up

All down Down

71A + 100A + 125A + 140A + 71A + 100A + 125A + 140A +


Efficiency data FVA + RZAG
71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5
Seasonal efficiency Cooling Energy efficiency class A++ A+ - A++ A+ -
(according to Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
EN14825) SEER 6.37 6.00 6.41 6.12 6.37 6.00 6.41 6,12
Annual energy consumption kWh 374 554 1133 1314 374 554 1133 1314
Heating (Average Energy efficiency class A+ - A+ -
climate) Pdesign kW 4.70 7.80 9.52 9.52 4.70 7.80 9.52 9.52
SCOP/A 4.05 4.20 4.15 3.94 4.05 4.20 4.15 3.94
Annual energy consumption kWh 1625 2600 3209 3383 1625 2600 3209 3383

Indoor unit FVA 71A 100A 125A 140A 71A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350 1,850x600x270 1,850x600x350
Weight Unit kg 39 47 39 47
Air filter Type Resin net with mold resistance
Fan - Air flow rate Cooling High/Low m³/min 18/14 28/22 28/24 30/26 18/14 28/22 28/24 30/26
Heating High/Low m³/min 18/14 28/22 28/24 30/26 18/14 28/22 28/24 30/26
Sound power level Cooling dBA 55 62 63 65 55 62 63 65
Heating dBA 55 62 63 65 55 62 63 65
Sound pressure level Cooling High/Low dBA 43/38 50/44 51/46 53/48 43/38 50/44 51/46 53/48
Heating High/Low dBA 43/38 50/44 51/46 53/48 43/38 50/44 51/46 53/48
Refrigerant Type R-32 / R-410A
Control systems Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

Outdoor unit RZAG 71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1
Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 70 92 78 70 92
Sound power level Cooling dBA 64 66 69 73 65 66 69 70
Sound pressure level Cooling Nom. dBA 46 47 50 54 46 47 50 51
Heating Nom. dBA 49 51 52 57 49 51 52
Operation range Cooling Ambient Min.~Max. °CDB -20~52 -15~46 -20~52
Heating Ambient Min.~Max. °CWB -20~18.0 -15~15.5 -20~18.0
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.90/1.96 2.95/1.99 3.75/2.53
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU
Max. m 55 85 50 55 85
length SystemEquivalent m 75 100 70 75 100
Chargeless m 40 30 40
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

52
SKY AIR INTRO
FVA-A + RZASG-MV1/MY1

Floor standing unit


For commercial spaces with high ceilings

INDOOR
UNITS
Combination with Sky Air Alpha-series ensures best in class quality,
highest efficiency and performance

ʯʯ Unified range for R-32 and R-410A simplifying stock


ʯʯ Ideal solution for commercial and busy environments
ʯʯ Decrease of temperature variation by automatic fan speed FVA71A
selection or freely selectable 3-step fan speed.
ʯʯ Improved comfort as a result of better airflow distribution from

OUTDOOR
UNITS
the vertical out blow which allows manual adjustment of air outlet
blades at the top of the unit.
ʯʯ Selectable horizontal out blow to better suit the layout of the
room (via wired remote controller BRC1E*)
ʯʯ No optional adapter needed for DIII-connection, link your unit into
the wider building management system. RZASG100-140MV1_MY1 BRC1H51W BRP069A81

AIR CURTAINS
BIDDLE
Side view blades air outlet

All up Up

All down Down

71A + 100A + 125A + 140A + 100A + 125A + 140A +


Efficiency data FVA + RZASG

VENTILATION
71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Power input Cooling Nom. kW - - - - - - -
Heating Nom. kW - - - - - - -
Seasonal efficiency Cooling Energy efficiency class A+ - A+ -
(according to Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
EN14825) SEER 5.83 5.72 5.52 5.63 5.72 5.52 5.63
Annual energy consumption kWh 408 581 1,370 1,428 581 1,370 1,428
Heating (Average Energy efficiency class A+ A - A -
climate) Pdesign kW 4.50 6.00 6.00 7.80 6.00 6.00 7.80

CONTROL
SYSTEMS
SCOP/A 4.04 3.83 3.64 3.81 3.83 3.64 3.81
Annual energy consumption kWh 2,297 2,654 2,764 - 2,654 2,764 -
Nominal efficiency EER 3.21 3.37 2.81 3.16 3.37 2.81 3.16
COP 3.69 3.65 3.47 3.41 3.65 3.47 3.41
Annual energy consumption kWh 1,559 2,193 2,308 2,866 2,193 2,308 2,866
Energy labeling Directive Cooling/Heating - - - - - - -

Indoor unit FVA 71A 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350

& ACCESSORIES
Weight Unit kg 39 47

OPTIONS
Air filter Type Resin net with mold resistance
Fan - Air flow rate Cooling High/Low m³/min 18/14 28/22 28/24 30/26 28/22 28/24 30/26
Heating High/Low m³/min 18/14 28/22 28/24 30/26 28/22 28/24 30/26
Sound power level Cooling dBA 55 62 63 65 62 63 65
Heating dBA 55 62 63 65 62 63 65
Sound pressure level Cooling High/Low dBA 43/38 50/44 51/46 53/48 50/44 51/46 53/48
Heating High/Low dBA 43/38 50/44 51/46 53/48 50/44 51/46 53/48
Refrigerant Type R-32 / R-410A
Control systems Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220
& PLATFORMS

Outdoor unit RZASG 71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1
TOOLS

Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320


Weight Unit kg 60 70 78 70 77
Sound power level Cooling dBA 65 70 71 73 70 71 73
Sound pressure level Cooling Nom. dBA 46 53 54 53 54
Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
TECHNICAL
DRAWINGS

Piping connections Liquid/Gas mm 9.52/15.9


Piping OU - IU
Max. m 50
length SystemEquivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16 20 16
PREVIOUS

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

53
54
SKY AIR INTRO
FNA-A + RXM-M9 Split

Concealed floor standing unit


Designed to be concealed in walls

INDOOR
UNITS
Combination with split outdoor units is ideal for small retail, offices
or ­residential applications

ʯʯ Unified range for R-32 and R-410A simplifying stock


ʯʯ Ideal for installation in offices, hotels
and residential applications FNQ-A
ʯʯ Blends unobtrusively with any
interior design: only the suction and

OUTDOOR
UNITS
discharge grills are visible
ʯʯ Its low height (620 mm) enables
the unit to fit perfectly beneath a
window
ʯʯ Requires very little installation space
as the depth is only 200mm RXM35M9 BRC1H51W BRP069A81
ʯʯ High ESP allows flexible installation

AIR CURTAINS
BIDDLE
Efficiency data FNA + RXM 25A + 25M9 35A + 35M9 50A + 50M9 60A + 60M9
Cooling capacity Nom. kW 2,60 3,40 5,00 6,00
Heating capacity Nom. kW 3,20 4,00 5,80 7,00
Power input Cooling Nom. kW 0,68 1,10 1,48 2,22
Heating Nom. kW 0,80 1,15 1,74 2,25
Seasonal efficiency Cooling Energy efficiency class A+ A

VENTILATION
(according to Pdesign kW 2,60 3,40 5,00 6,00
EN14825) SEER 5,68 5,70 5,77 5,56
Annual energy consumption kWh 160 209 303 378
Heating (Average Energy efficiency class A+
climate) Pdesign kW 2,80 2,90 4,00 4,60
SCOP/A 4,24 4,05 4,09 4,16
Annual energy consumption kWh 924 1002 1369 1547
Nominal efficiency EER 3.80 3.09 3.38 2.70
COP 4.00 3.48 3.34 3.11
Annual energy consumption kWh - - - -

CONTROL
SYSTEMS
Energy labeling Directive Cooling/Heating - - - -

Indoor unit FNA 25A 35A 50A 60A


Dimensions Unit HeightxWidthxDepth mm 620 / 720(2)x750x200 620 / 720(2)x1,150x200
Weight Unit kg 23 30
Air filter Type Resin net with mold resistance
Fan - Air flow rate Cooling High/Low m³/min 8.7/7.3 16.0/13.5
Heating High/Low m³/min 8.7/7.3 16.0/13.5

& ACCESSORIES
Fan - External static pressure High/Nom./Maximum available/High Pa 48/30/- 49/40/-
Sound power level Cooling dBA 53 56

OPTIONS
Sound pressure level Cooling High/Low dBA 33/28 36/30
Heating High/Low dBA 33/28 36/30
Refrigerant Type R-32 / R-410A
Control systems Infrared remote control BRC4C65
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

Outdoor unit RXM 25M9 35M9 50M9 60M9


Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300
& PLATFORMS

Weight Unit kg 32 47
Sound power level Cooling dBA 59 61 62 63
TOOLS

Heating dBA 59 61 62 63
Sound pressure level Cooling Low/High dBA 46/- 49/- 48/44
Heating Low/High dBA 47/- 49/- 49/45
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-32
GWP 675.0
Charge kg/TCO2Eq 0.76/0.52 1.40/0.95 1.45/0.98
Piping connections Liquid OD mm 6,35 6,4
TECHNICAL
DRAWINGS

Gas OD mm 9.50 12.7


Piping OU - IU Max. m 20.0 30
length System Chargeless m 10.0 -
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Current - 50Hz Maximum fuse amps (MFA) A 10 15

(1) EER/COP according to Eurovent 2012, for use outside EU only


PREVIOUS

(2) Including installation legs (3) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer
to the electrical data drawing.

55
FNA-A + RXM-M9 Split

Concealed floor standing unit


Designed to be concealed in walls

Combination with split outdoor units is ideal for small retail, offices
or ­residential applications

ʯʯ Unified range for R-32 and R-410A simplifying stock


ʯʯ Ideal for installation in offices, hotels
and residential applications FNQ-A
ʯʯ Blends unobtrusively with any
interior design: only the suction and
discharge grills are visible
ʯʯ Its low height (620 mm) enables
the unit to fit perfectly beneath a
window
ʯʯ Requires very little installation space
as the depth is only 200mm RXM35M9 BRC1E53A-B-C BRC4C65
ʯʯ High ESP allows flexible installation

NEW
Online controller connection
Efficiency data FNA + RXM 25A + 25M9 35A + 35M9 50A + 50M9 60A + 60M9
Cooling capacity Nom. kW 2,60 3,40 5,00 6,00
Heating capacity Nom. kW 3,20 4,00 5,80 7,00
Power input Cooling Nom. kW 0,68 1,10 1,48 2,22
Heating Nom. kW 0,80 1,15 1,74 2,25
Seasonal efficiency Cooling Energy efficiency class A+ A
(according to Pdesign kW 2,60 3,40 5,00 6,00
EN14825) SEER 5,68 5,70 5,77 5,56
Annual energy consumption kWh 160 209 303 378
Heating (Average Energy efficiency class A+
climate) Pdesign kW 2,80 2,90 4,00 4,60
SCOP/A 4,24 4,05 4,09 4,16
Annual energy consumption kWh 924 1002 1369 1547
Nominal efficiency EER 3.80 3.09 3.38 2.70
COP 4.00 3.48 3.34 3.11
Annual energy consumption kWh - - - -
Energy labeling Directive Cooling/Heating - - - -

Indoor unit FNA 25A 35A 50A 60A


Dimensions Unit HeightxWidthxDepth mm 620 / 720(2)x750x200 620 / 720(2)x1,150x200
Weight Unit kg 23 30
Air filter Type Resin net with mold resistance
Fan - Air flow rate Cooling High/Low m³/min 8.7/7.3 16.0/13.5
Heating High/Low m³/min 8.7/7.3 16.0/13.5
Fan - External static pressure High/Nom./Maximum available/High Pa 48/30/- 49/40/-
Sound power level Cooling dBA 53 56
Sound pressure level Cooling High/Low dBA 33/28 36/30
Heating High/Low dBA 33/28 36/30
Refrigerant Type R-32 / R-410A
Control systems Infrared remote control BRC4C65

Sky Air, from high


Power supply

Outdoor unit
Wired remote control
Phase / Frequency / Voltage Hz / V

RXM 25M9
BRC1D52 / BRC1E53A / BRC1E53B / BRC1E53C
1~ / 50/60 / 220-240/220

35M9 50M9 60M9

specification, tailored
Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300
Weight Unit kg 32 47
Sound power level Cooling dBA 59 61 62 63
Heating dBA 59 61 62 63

solutions to primary
Sound pressure level Cooling

Operation range
Heating
Cooling
Heating
Low/High
Low/High
Ambient
Ambient
Min.~Max.
Min.~Max.
dBA
dBA
°CDB
°CWB
46/-
47/-
49/-
49/-
-10~46
-15~18
48/44
49/45

cooling and heating


Refrigerant Type
GWP
Charge kg/TCO2Eq 0.76/0.52
R-32
675.0
1.40/0.95 1.45/0.98
Piping connections Liquid OD mm 6,35 6,4
Gas OD mm 9.50 12.7
Piping OU - IU Max. m 20.0 30
length System Chargeless m 10.0 -
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Current - 50Hz Maximum fuse amps (MFA) A 10 15

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) Including installation legs (3) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer
to the electrical data drawing.

56
SKY AIR INTRO
Combinations
with R-410A

INDOOR
UNITS
outdoor units

OUTDOOR
UNITS
AIR CURTAINS
Ceiling mounted cassettes 58

BIDDLE
FCAHG-G 58
FCAG-A 60
FFA-A 64


Concealed ceiling units 65

VENTILATION
FDXM-F3 66
FBA-A 67
FDA-A 70
FDQ-B 71
ADEQ-C 72
ABQ-C 73

CONTROL
SYSTEMS
Wall mounted units 75
FAA-A 75

Ceiling suspended units 77

& ACCESSORIES
OPTIONS
FHA-A 77
FUA-A  82

Floor standing units 84


& PLATFORMS

FVA-A 84
TOOLS

Concealed floor standing units 87


FNA-A 87
TECHNICAL
DRAWINGS
PREVIOUS

57
FCAHG-G + RZQG-L9V1/L(8)Y1

High COP, round flow cassette


360° air discharge for optimum efficiency and comfort

ʯʯ Combination with Seasonal Smart ensures best in class quality,


highest efficiency and performance
ʯʯ High COP cassette ensures top performance, great savings
in energy consumption and a comfortable environment for
commercial applications
ʯʯ Unified indoor unit range for R-32 and R-410A FCAHG-G
ʯʯ Automatic filter cleaning results in higher efficiency & comfort
and lower maintenance costs. 2 filters available: standard filter and
finer mesh filter (for fine dust applications e.g. clothing shops)
ʯʯ Two optional intelligent sensors improve energy efficiency and
comfort.
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
ʯʯ Modern style decoration panel is available in 3 different variations: RZQG125-140L9V1_L(8)Y1 BRC1H51W BRP069A81
white (RAL9010) with grey louvers, full white (RAL9010) or auto
cleaning panel
ʯʯ 5 different fan speeds available for maximum comfort ʯʯ Branch duct discharge allows to optimize air distribution in
ʯʯ Reduced energy consumption thanks to specially developed small irregular shaped rooms or to supply air to small adjacent rooms
tube heat exchanger, DC fan motor and drain pump ʯʯ Standard drain pump with 675mm lift increases flexibility and
ʯʯ Optional fresh air intake installation speed

71G + 100G + 125G + 140G + 71G + 100G + 125G + 140G +


Efficiency data FCAHG + RZQG
71L9V1 100L9V1 125L9V1 140L9V1 71L8Y1 100L8Y1 125L8Y1 140LY1
Cooling capacity Nom. kW 6.80 9.50 12.0 13.4 6.80 9.50 12.0 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5
Power input Cooling Nom. kW 1.66 2.15 3.00 4.00 1.66 2.15 3.00 4.00
Heating Nom. kW 1.56 2.16 3.07 3.77 1.56 2.16 3.07 3.77
Seasonal efficiency Cooling Energy efficiency class A++ - A++ -
(according to Pdesign kW 6.80 9.50 12.0 - 6.80 9.50 12.0 -
EN14825) SEER 6.91 7.00 6.61 - 6.91 7.00 6.61 -
Annual energy consumption kWh 345 475 636 - 345 475 636 -
Heating (Average Energy efficiency class A+ A++ - A+ A++ -
climate) Pdesign kW 7.60 11.30 12.66 - 7.60 11.30 12.66 -
SCOP/A 4.54 4.80 4.63 - 4.54 4.80 4.63 -
Annual energy consumption kWh 2,344 3,296 3,829 - 2,344 3,296 3,829 -
Nominal efficiency EER 4.09 4.42 4.00 3.35 4.09 4.42 4.00 3.35
COP 4.80 4.99 4.40 4.12 4.80 4.99 4.40 4.12
Annual energy consumption kWh 830 1,075 1,500 - 830 1,075 1,500 -
Energy labeling Directive Cooling/Heating A/A -/- A/A -/-

Indoor unit FCAHG 71G 100G 125G 140G 71G 100G 125G 140G
Dimensions Unit HeightxWidthxDepth mm 288x840x840
Weight Unit kg 25
Air filter Type Resin net
Decoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW
- full white / BYCQ140D - white with grey louvers
Colour Pure White (RAL 9010)
Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950
Weight kg 10.3 / 10.3 / 5.4 / 5.4
Fan Air flow rate Cooling Low/Medium/High m³/min 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5
Heating Low/Medium/High m³/min 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5
Sound power level Cooling dBA 53 61 53 61
Heating dBA 53 61 53 61
Sound pressure level Cooling Low/High dBA 29/36 33/44 35/45 37/45 29/36 33/44 35/45 37/45
Heating Low/High dBA 29/36 33/44 35/45 37/45 29/36 33/44 35/45 37/45
Control systems Infrared remote control BRC7FA532F
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RZQG 71L9V1 100L9V1 125L9V1 140L9V1 71L8Y1 100L8Y1 125L8Y1 140LY1
Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 69 95 80 101
Sound power level Cooling dBA 64 66 67 69 64 66 67 69
Sound pressure level Cooling Nom. dBA 48 50 51 52 48 50 51 52
Heating Nom. dBA 50 52 53 50 52 53
Operation range Cooling Ambient Min.~Max. °CDB -15~50
Heating Ambient Min.~Max. °CWB -20~15.5
Refrigerant Type/GWP R-410A/2,087.5
Charge kg/TCO2Eq 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50 75 50 75
length System Equivalent m 70 90 70 90
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 25 40 16 25
The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in
environments exposed to concentrations of dirt. | BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto
cleaning panel. | MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical
data drawing.

58
SKY AIR INTRO
FCAHG-G + RZQSG-L3/9V1/L(8)Y1

High COP, round flow cassette


360° air discharge for optimum efficiency and comfort

INDOOR
UNITS
ʯʯ Combination with Seasonal Classic ensures good value for money
for all types of commercial applications
ʯʯ High COP cassette ensures top performance, great savings
in energy consumption and a comfortable environment for
commercial applications
ʯʯ Unified indoor unit range for R-32 and R-410A FCAHG-G
ʯʯ Automatic filter cleaning results in higher efficiency & comfort
and lower maintenance costs. 2 filters available: standard filter and

OUTDOOR
UNITS
finer mesh filter (for fine dust applications e.g. clothing shops)
ʯʯ Two optional intelligent sensors improve energy efficiency and
comfort.
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
ʯʯ Modern style decoration panel is available in 3 different variations: RZQSG71-100-125L9V1/L(8)Y1 BRC1H51W BRP069A81
white (RAL9010) with grey louvers, full white (RAL9010) or auto

AIR CURTAINS
cleaning panel

BIDDLE
100G + 125G + 140G + 100G + 125G +
Efficiency data FCAHG + RZQSG 71G + 71L3V1 140G + 140LY1
100L9V1 125L9V1 140L9V1 100L8Y1 125L8Y1
Cooling capacity Nom. kW 6.80 9.50 12.0 13.4 9.50 12.0 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5

VENTILATION
Power input Cooling Nom. kW 1.94 2.57 3.71 4.17 2.57 3.71 4.17
Heating Nom. kW 1.83 2.51 3.60 4.29 2.51 3.60 4.29
Seasonal efficiency Cooling Energy efficiency class A++ A - A++ A -
(according to Pdesign kW 6.80 9.50 12.0 - 9.50 12.0 -
EN14825) SEER 6.50 6.70 5.40 - 6.70 5.40 -
Annual energy consumption kWh 367 497 778 - 497 778 -
Heating (Average Energy efficiency class A+ - A+ -
climate) Pdesign kW 7.60 8.03 - 8.03 -
SCOP/A 4.15 4.30 4.10 - 4.30 4.10 -
Annual energy consumption kWh 2,563 2,615 2,742 - 2,615 2,742 -
Nominal efficiency EER 3.50 3.70 3.23 3.21 3.70 3.23 3.21

CONTROL
SYSTEMS
COP 4.10 4.30 3.75 3.61 4.30 3.75 3.61
Annual energy consumption kWh 970 1,285 1,855 - 1,285 1,855 -
Energy labeling Directive Cooling/Heating A/A -/- A/A -/-

Indoor unit FCAHG 71G 100G 125G 140G 100G 125G 140G
Dimensions Unit HeightxWidthxDepth mm 288x840x840
Weight Unit kg 25
Air filter Type Resin net
Decoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW
- full white / BYCQ140D - white with grey louvers

& ACCESSORIES
Colour Pure White (RAL 9010)

OPTIONS
Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950
Weight kg 10.3 / 10.3 / 5.4 / 5.4
Fan Air flow rate Cooling Low/Medium/High m³/min 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5
Heating Low/Medium/High m³/min 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5
Sound power level Cooling dBA 53 61
Heating dBA 53 61
Sound pressure level Cooling Low/High dBA 29/36 33/44 35/45 37/45 33/44 35/45 37/45
Heating Low/High dBA 29/36 33/44 35/45 37/45 33/44 35/45 37/45
Control systems Infrared remote control BRC7FA532F
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
& PLATFORMS

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220


TOOLS

Outdoor unit RZQSG 71L3V1 100L9V1 125L9V1 140L9V1 100L8Y1 125L8Y1 140LY1
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 67 72 74 95 82 101
Sound power level Cooling dBA 65 70 69 70 69
Sound pressure level Cooling Nom./Silent operation dBA 49/47 53/- 54/- 53/- 54/- 53/-
Heating Nom. dBA 51 57 58 54 57 58 54
Operation range Cooling Ambient Min.~Max. °CDB -15.0~46 -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-410A/2,087.5
Charge kg/TCO2Eq 2.75/5.7 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4
TECHNICAL
DRAWINGS

Piping connections Liquid/Gas mm 9.52/15.9


Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 15 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 - 16 20
The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in
environments exposed to concentrations of dirt. | BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto
PREVIOUS

cleaning panel. | MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical
data drawing.

59
FCAG-A + RZQG-L9V1/L(8)Y1

Round flow cassette


360° air discharge for optimum efficiency and comfort

ʯʯ Combination with Seasonal Smart ensures best in class quality,


highest efficiency and performance
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Automatic filter cleaning results in higher efficiency & comfort
and lower maintenance costs. 2 filters available: standard filter and
finer mesh filter (for fine dust applications e.g. clothing shops) FCAG-A
ʯʯ Two optional intelligent sensors improve energy efficiency and
comfort.
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
ʯʯ Lowest installation height in the market: 214mm for class 20-63
ʯʯ Modern style decoration panel is available in 3 different variations:
white (RAL9010) with grey louvers, full white (RAL9010) or auto
cleaning panel RZQG100-125-140L9V1/L(8)Y1 BRC1H51W BRP069A81
ʯʯ 5 different fan speeds available for maximum comfort
ʯʯ Reduced energy consumption thanks to specially developed small
tube heat exchanger, DC fan motor and drain pump ʯʯ Standard drain pump with 675mm lift increases flexibility and
ʯʯ Optional fresh air intake installation speed
ʯʯ Branch duct discharge allows to optimize air distribution in
irregular shaped rooms or to supply air to small adjacent rooms

71A + 100A + 125A + 140A + 71A + 100A + 125A + 140A +


Efficiency data FCAG + RZQG
71L9V1 100L9V1 125L9V1 140L9V1 71L8Y1 100L8Y1 125L8Y1 140LY1
Cooling capacity Nom. kW 6.80 9.50 12.0 13.4 6.80 9.50 12.0 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5
Power input Cooling Nom. kW 2.01 2.45 3.22 - 2.01 2.45 3.22 4.17
Heating Nom. kW 1.89 2.60 3.72 - 1.89 2.60 3.72 4.30
Seasonal efficiency Cooling Energy efficiency class A++ A+ - A++ A+ -
(according to Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -
EN14825) SEER 6.72 6.80 6.00 - 6.72 6.80 6.00 -
Annual energy consumption kWh 355 489 700 - 355 489 700 -
Heating (Average Energy efficiency class A+ A++ A+ - A+ A++ A+ -
climate) Pdesign kW 6.33 11.30 12.66 - 6.33 11.30 12.66 -
SCOP/A 4.20 4.61 4.10 - 4.20 4.61 4.10 -
Annual energy consumption kWh 2,110 3,432 4,323 - 2,110 3,432 4,323 -
Nominal efficiency EER 3.39 3.87 3.73 3.21 3.39 3.87 3.73 3.21
COP 3.97 4.15 3.63 3.61 3.97 4.15 3.63 3.61
Annual energy consumption kWh 1,005 1,225 1,610 - 1,005 1,225 1,610 -
Energy labeling Directive Cooling/Heating A/A -/- A/A -/-

Indoor unit FCAG 71A 100A 125A 140A 71A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840 204x840x840 246x840x840
Weight Unit kg 21 24 21 24
Air filter Type Resin net
Decoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW
- full white / BYCQ140D - white with grey louvers
Colour Pure White (RAL 9010)
Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950
Weight kg 10.3 / 10.3 / 5.4 / 5.4
Fan Air flow rate Cooling Low/Medium/High m³/min 9.3/12.5/15.3 12.4/17.6/22.8 12.4/19.2/26.0 9.3/12.5/15.3 12.4/17.6/22.8 12.4/19.2/26.0
Heating Low/Medium/High m³/min 9.1/12.1/15.0 12.4/17.6/22.8 12.4/19.2/26.0 9.1/12.1/15.0 12.4/17.6)/22.8 12.4/19.2/26.0
Sound power level Cooling dBA 51 54 58 51 54 58
Heating dBA 51 54 58 51 54 58
Sound pressure level Cooling Low/High dBA 28/35 29/37 29/41 28/35 29/37 29/41
Heating Low/High dBA 28/33 29/37 29/41 28/33 29/37 29/41
Control systems Infrared remote control BRC7FA532F
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RZQG 71L9V1 100L9V1 125L9V1 140L9V1 71L8Y1 100L8Y1 125L8Y1 140LY1
Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 69 95 80 101
Sound power level Cooling dBA 64 66 67 69 64 66 67 69
Sound pressure level Cooling Nom. dBA 48 50 51 52 48 50 51 52
Heating Nom. dBA 50 52 53 50 52 53
Operation range Cooling Ambient Min.~Max. °CDB -15~50
Heating Ambient Min.~Max. °CWB -20~15.5
Refrigerant Type/GWP R-410A/2,087.5
Charge kg/TCO2Eq 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50 75 50 75
length System Equivalent m 70 90 70 90
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 25 40 16 25
The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in
environments exposed to concentrations of dirt. | BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto
cleaning panel. | MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical
data drawing.

60
SKY AIR INTRO
FCAG-A + RZQSG-L3/9V1/L(8)Y1

Round flow cassette


360° air discharge for optimum efficiency and comfort

INDOOR
UNITS
ʯʯ Combination with Seasonal Classic ensures good value for money
for all types of commercial applications
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Automatic filter cleaning results in higher efficiency & comfort
and lower maintenance costs. 2 filters available: standard filter and
finer mesh filter (for fine dust applications e.g. clothing shops) FCAG-A
ʯʯ Two optional intelligent sensors improve energy efficiency and
comfort.

OUTDOOR
UNITS
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
ʯʯ Lowest installation height in the market: 214mm for class 20-63
ʯʯ Modern style decoration panel is available in 3 different variations:
white (RAL9010) with grey louvers, full white (RAL9010) or auto
cleaning panel RZQSG71-100-125l9V1/L(8)Y1 BRC1H51W BRP069A81

AIR CURTAINS
BIDDLE
100A + 125A + 140A + 100A + 125A +
Efficiency data FCAG + RZQSG 71A + 71L3V1 140A + 140LY1
100L9V1 125L9V1 140L9V1 100L8Y1 125L8Y1
Cooling capacity Nom. kW 6.80 9.50 12.0 13.4 9.50 12.0 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Power input Cooling Nom. kW 2.12 2.88 3.74 4.45 2.88 3.74 4.45
Heating Nom. kW 2.08 3.05 3.96 4.54 3.05 3.96 4.54
Seasonal efficiency Cooling Energy efficiency class A++ A - A++ A -

VENTILATION
(according to Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -
EN14825) SEER 6.10 6.50 5.30 - 6.50 5.30 -
Annual energy consumption kWh 391 512 793 - 512 793 -
Heating (Average Energy efficiency class A+ - A+ -
climate) Pdesign kW 6.33 7.60 8.03 - 7.60 8.03 -
SCOP/A 4.10 4.01 - 4.10 4.01 -
Annual energy consumption kWh 2,162 2,596 2,804 - 2,596 2,804 -
Nominal efficiency EER 3.21 3.30 3.21 3.01 3.30 3.21 3.01
COP 3.61 3.54 3.41 3.54 3.41
Annual energy consumption kWh 1,060 1,440 1,870 - 1,440 1,870 2,225
Energy labeling Directive Cooling/Heating A/A A/B -/- A/A A/B -/-

CONTROL
SYSTEMS
Indoor unit FCAG 71A 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840 246x840x840
Weight Unit kg 21 24 24
Air filter Type Resin net
Decoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW
- full white / BYCQ140D - white with grey louvers
Colour Pure White (RAL 9010)
Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950

& ACCESSORIES
Weight kg 10.3 / 10.3 / 5.4 / 5.4

OPTIONS
Fan Air flow rate Cooling Low/Medium/High m³/min 9.3/12.5/15.3 12.4/17.6/22.8 12.4/19.2/26.0 12.4/17.6/22.8 12.4/19.2/26.0
Heating Low/Medium/High m³/min 9.1/12.1/15.0 12.4/17.6/22.8 12.4/19.2/26.0 12.4/17.6)/22.8 12.4/19.2/26.0
Sound power level Cooling dBA 51 54 58 54 58
Heating dBA 51 54 58 54 58
Sound pressure level Cooling Low/High dBA 28/35 29/37 29/41 29/37 29/41
Heating Low/High dBA 28/33 29/37 29/41 29/37 29/41
Control systems Infrared remote control BRC7FA532F
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
& PLATFORMS

Outdoor unit RZQSG 71L3V1 100L9V1 125L9V1 140L9V1 100L8Y1 125L8Y1 140LY1
TOOLS

Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 990x940x320 1,430x940x320


Weight Unit kg 67 72 74 95 82 101
Sound power level Cooling dBA 65 70 69 70 69
Sound pressure level Cooling Nom./Silent operation dBA 49/47 53/- 54/- 53/- 54/- 53/-
Heating Nom. dBA 51 57 58 54 57 58 54
Operation range Cooling Ambient Min.~Max. °CDB -15.0~46 -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-410A/2,087.5
Charge kg/TCO2Eq 2.75/5.7 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4
TECHNICAL
DRAWINGS

Piping connections Liquid/Gas mm 9.52/15.9


Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 15 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 - 16 20
The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in
environments exposed to concentrations of dirt. | BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto
PREVIOUS

cleaning panel. | MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical
data drawing.

61
FCAG-A + AZQS-B(8)V1/BY1

Round flow cassette


360° air discharge for optimum efficiency and comfort

ʯʯ Unified indoor unit range for R-32 and R-410A


ʯʯ Automatic filter cleaning results in higher efficiency & comfort
and lower maintenance costs. 2 filters available: standard filter and
finer mesh filter (for fine dust applications e.g. clothing shops)
ʯʯ Two optional intelligent sensors improve energy efficiency and
comfort. FCAG-A
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
ʯʯ Lowest installation height in the market: 214mm for class 20-63
ʯʯ Modern style decoration panel is available in 3 different variations:
white (RAL9010) with grey louvers, full white (RAL9010) or auto
cleaning panel

AZQS140B8V1/BY1 BRC1H51W BRP069A81

71A + 100A + 125A + 140A +


Efficiency data FCAG + AZQS 100A + 100BY1 125A + 125BY1 140A + 140BY1
71BV1 100B8V1 125B8V1 140B8V1
Cooling capacity Nom. kW 6.80 9.5 12.1 13.0 9.5 12.1 13.0
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Power input Cooling Nom. kW 2.19 2.96 3.90 4.63 2.96 3.90 4.63
Heating Nom. kW 2.08 3.09 3.96 4.70 3.09 3.96 4.70
Seasonal efficiency Cooling Energy efficiency class A+ A - A -
(according to Pdesign kW 6.80 9.50 - 9.50 -
EN14825) SEER 5.70 5.50 - 5.50 -
Annual energy consumption kWh 418 605 - 605 -
Heating (Average Energy efficiency class A+ A - A -
climate) Pdesign kW 6.33 7.60 - 7.60 -
SCOP/A 4.00 3.85 - 3.85 -
Annual energy consumption kWh 2,216 2,762 - 2,764 -
Nominal efficiency EER 3.11 3.21 3.10 2.81 3.21 3.10 2.81
COP 3.61 3.50 3.41 3.30 3.50 3.41 3.30
Annual energy consumption kWh 1,093 1,480 1,952 2,313 1,480 1,952 2,313
Energy labeling Directive Cooling/Heating B/A A/B B/B C/C A/B B/B -/-

Indoor unit FCAG 71A 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840
Weight Unit kg 21 24
Air filter Type Resin net
Decoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW - full
white / BYCQ140D - white with grey louvers
Colour Pure White (RAL 9010)
Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950
Weight kg 10.3 / 10.3 / 5.4 / 5.4
Fan Air flow rate Cooling Low/Medium/High m³/min 9.3/12.5/15.3 12.4/17.6/22.8 12.4/19.2/26.0 12.4/17.6/22.8 12.4/19.2/26.0
Heating Low/Medium/High m³/min 9.1/12.1/15.0 12.4/17.6/22.8 12.4/19.2/26.0 12.4/17.6/22.8 12.4/19.2/26.0
Sound power level Cooling dBA 51 54 58 54 58
Heating dBA 51 54 58 54 58
Sound pressure level Cooling Low/High dBA 28/35 29/37 29/41 29/37 29/41
Heating Low/High dBA 28/33 29/37 29/41 29/37 29/41
Control systems Infrared remote control BRC7FA532F
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit AZQS/AZQS 71BV1 100B8V1 125B8V1 140B8V1 100BY1 125BY1 140BY1
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 67 72.8 74.3 94.9 82 101
Sound power level Cooling dBA 64 70 71 70 71 70
Sound pressure level Cooling Nom. dBA 48 53 54 53 54 53
Heating Nom. dBA 50 57 58 54 57 58 54
Night quiet mode Level 1 dBA 43 49
Operation range Cooling Ambient Min.~Max. °CDB -5~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-410A/2,087.5
Charge kg/TCO2Eq 2.75/5.7 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16 20
EER/COP according to Eurovent 2012, for use outside EU only | The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not
advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. | BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard
panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.

62
SKY AIR INTRO
FCAG-A + RXS-L(3) Split

Round flow cassette


360° air discharge for optimum efficiency and comfort

INDOOR
UNITS
ʯʯ Combination with split outdoor units is ideal for small retail,
offices or residential applications
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Automatic filter cleaning results in higher efficiency & comfort
and lower maintenance costs. 2 filters available: standard filter and
finer mesh filter (for fine dust applications e.g. clothing shops) FCAG-A
ʯʯ Two optional intelligent sensors improve energy efficiency and
comfort.

OUTDOOR
UNITS
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
ʯʯ Lowest installation height in the market: 214mm for class 20-63
ʯʯ Modern style decoration panel is available in 3 different variations:
white (RAL9010) with grey louvers, full white (RAL9010) or auto
cleaning panel RXS35L3 BRC1H51W BRP069A81

AIR CURTAINS
BIDDLE
Efficiency data FCAG + RXS 35A + 35L3 50A + 50L 60A + 60L
Cooling capacity Nom. kW 3.40 5.00 5.70
Heating capacity Nom. kW 4.20 6.00 7.00
Power input Cooling Nom. kW 0.91 1.41 1.64
Heating Nom. kW 1.20 1.62 1.99

VENTILATION
Seasonal efficiency Cooling Energy efficiency class A++
(according to Pdesign kW 3.50 5.00 5.70
EN14825) SEER 6.35 6.48 6.22
Annual energy consumption kWh 193 270 321
Heating (Average Energy efficiency class A++ A+
climate) Pdesign kW 3.32 4.36 4.71
SCOP/A 4.90 4.29 4.00
Annual energy consumption kWh 949 1,426 1,646
Nominal efficiency EER 3.74 3.55 3.48
COP 3.50 3.70 3.52
Annual energy consumption kWh 455 705 820

CONTROL
SYSTEMS
Energy labeling Directive Cooling/Heating A/B A/A A/B

Indoor unit FCAG 35A 50A 60A


Dimensions Unit HeightxWidthxDepth mm 204x840x840
Weight Unit kg 18 19
Air filter Type Resin net
Decoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW
- full white / BYCQ140D - white with grey louvers
Colour Pure White (RAL 9010)
Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950

& ACCESSORIES
Weight kg 10.3 / 10.3 / 5.4 / 5.4

OPTIONS
Fan Air flow rate Cooling Low/Medium/High m³/min 8.7/10.6/12.5 8.7/10.7/12.6 8.7/11.2/13.6
Heating Low/Medium/High m³/min 9.3/11.6/13.9 8.7/10.7/12.6 8.7/11.2/13.6
Sound power level Cooling dBA 49 51
Heating dBA 49 51
Sound pressure level Cooling Low/High dBA 27/31 28/33
Heating Low/High dBA 27/31 28/33
Control systems Infrared remote control BRC7FA532F
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
& PLATFORMS

Outdoor unit RXS 35L3 50L 60L


TOOLS

Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300


Weight Unit kg 34 47 48
Sound power level Cooling dBA 61 62
Heating dBA 61 62
Sound pressure level Cooling Low/High dBA -/48 44/48 46/49
Heating Low/High dBA -/48 45/48 46/49
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-410A
GWP 2,087.5
TECHNICAL
DRAWINGS

Charge kg/TCO2Eq 1.2/2.5 1.7/3.5 1.5/3.1


Piping connections Liquid OD mm 6.35
Gas OD mm 9.5 12.7
Piping OU - IU Max. m 20 30
length System Chargeless m 10 -
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.020 (for piping length exceeding 10m)
Level difference IU - OU Max. m 15 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 1~/50/220-230-240
Current - 50Hz Maximum fuse amps (MFA) A -
EER/COP according to Eurovent 2012, for use outside EU only | The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not
PREVIOUS

advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt. | BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard
panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.

63
FFA-A + RXS-L(3) Split

Fully flat cassette


Unique design in the market that integrates fully flat into
the ceiling

ʯʯ Combination with split outdoor units is ideal for small retail,


offices or residential applications
ʯʯ Fully flat integration in standard architectural ceiling tiles, leaving
only 8mm
ʯʯ Remarkable blend of iconic design and engineering excellence FFA-A
with an elegant finish in white or a combination of silver and
white
ʯʯ Unified indoor unit range for R-32 and R-410A
ʯʯ Two optional intelligent sensors improve energy efficiency and
comfort.
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
ʯʯ Reduced energy consumption thanks to specially developed small RX35L3 BRC1H51W BRP069A81
tube heat exchanger, DC fan motor and drain pump
ʯʯ Optional fresh air intake
ʯʯ Branch duct discharge allows to optimize air distribution in
irregular shaped rooms or to supply air to small adjacent rooms
ʯʯ Standard drain pump with 630mm lift increases flexibility and
installation speed
Efficiency data FFA + RXS 25A + 25L3 35A + 35L3 50A + 50L 60A + 60L
Cooling capacity Nom. kW 2.50 3.40 5.00 5.70
Heating capacity Nom. kW 3.20 4.20 5.80 7.00
Power input Cooling Nom. kW 0.55 0.90 1.56 1.89
Heating Nom. kW 0.82 1.20 1.66 2.05
Seasonal efficiency Cooling Energy efficiency class A++ A+
(according to Pdesign kW 2.50 3.40 5.00 5.70
EN14825) SEER 6.11 6.32 5.93 5.71
Annual energy consumption kWh 143 188 295 349
Heating (Average Energy efficiency class A+ A A+
climate) Pdesign kW 2.31 3.10 3.84 3.96
SCOP/A 4.24 4.10 3.90 4.04
Annual energy consumption kWh 763 1,059 1,378 1,373
Nominal efficiency EER 4.53 3.78 3.21 3.02
COP 3.90 3.50 3.49 3.41
Annual energy consumption kWh 276 450 780 945
Energy labeling Directive Cooling/Heating A/A A/B B/B

Indoor unit FFA 25A 35A 50A 60A


Dimensions Unit HeightxWidthxDepth mm 260x575x575
Weight Unit kg 16.0 17.5
Air filter Type Resin net
Decoration panel Model BYFQ60C2W1W/BYFQ60C2W1S/BYFQ60B2W1/BYFQ60B3W1
Colour White (N9.5)/SILVER/White (RAL9010)/WHITE (RAL9010)
Dimensions HeightxWidthxDepth mm 46x620x620 / 46x620x620 / 55x700x700 / 55x700x700
Weight kg 2.8/2.8/2.7/2.7
Fan Air flow rate Cooling Low/Medium/High m³/min 6.5/8.0 /9.0 6.5/8.5 /10.0 7.5/10.0 /12.0 9.5/12.5 /14.5
Heating Low/Medium/High m³/min 6.5/8.0 /9.0 6.5/8.5 /10.0 7.5/10.0 /12.0 9.5/12.5 /14.5
Sound power level Cooling dBA 48 51 56 60
Sound pressure level Cooling Low/High dBA 25.0/31.0 25.0/34.0 27.0/39.0 32.0/43.0
Heating Low/High dBA 25.0/31.0 25.0/34.0 27.0/39.0 32.0/43.0
Control systems Infrared remote control BRC7EB530W (standard panel) / BRC7F530W (white panel) / BRC7F530S (grey panel)
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RXS 25L3 35L3 50L 60L


Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300
Weight Unit kg 34 47 48
Sound power level Cooling dBA 59 61 62
Heating dBA 59 61 62
Sound pressure level Cooling Low/High dBA -/46 -/48 44/48 46/49
Heating Low/High dBA -/47 -/48 45/48 46/49
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-410A
GWP 2,087.5
Charge kg/TCO2Eq 1.0/2.1 1.2/2.5 1.7/3.5 1.5/3.1
Piping connections Liquid OD mm 6.35
Gas OD mm 9.5 12.7
Piping OU - IU Max. m 20 30
length System Chargeless m 10 -
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.020 (for piping length exceeding 10m)
Level difference IU - OU Max. m 15 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 1~/50/220-230-240
Current - 50Hz Maximum fuse amps (MFA) A -

64
65
TECHNICAL TOOLS OPTIONS CONTROL BIDDLE OUTDOOR INDOOR
PREVIOUS VENTILATION SKY AIR INTRO
DRAWINGS & PLATFORMS & ACCESSORIES SYSTEMS AIR CURTAINS UNITS UNITS
FDXM-F3 + RXS-L(3) Split

Concealed ceiling unit rear


suction

Compact concealed ceiling unit, with a height of only


200mm

ʯʯ Invisible unit as the unit is concealed in the ceiling: only the outblow
suction and discharge grilles are visible
ʯʯ Compact dimensions, can easily be mounted in a ceiling void of
only 240mm
ʯʯ Medium external static pressure up to 40Pa facilitates unit use FDXM-F3 bottom
suction
with flexible ducts of varying lengths
ʯʯ Unified indoor unit range for R-32 and R-410A
NEW ʯʯ Auto cleaning filter option ensures maximum efficiency, comfort
and reliability by regular filter cleaning
NEW
with auto
NEW ʯʯ Multi zoning kit allows multiple individually-controlled climate cleaning and
zones to be served by one indoor unit multi zoning
ʯʯ Online controller (optional): control your indoor from any location option
with an app, via your local network or internet and keep an RXS25-35L3 BRC1H51W BRP069A81
overview on your energy consumption
ʯʯ Low energy consumption thanks to DC fan motor

Efficiency data FDXM + RXS 25F3 + 25L3 35F3 + 35L3 50F3 + 50L 60F3 + 60L
Cooling capacity Nom. kW 2.40 3.40 5.00 6.00
Heating capacity Nom. kW 3.20 4.00 5.80 7.00
Power input Cooling Nom. kW 0.64 1.15 1.65 2.06
Heating Nom. kW 0.80 1.15 1.87 2.18
Seasonal efficiency Cooling Energy efficiency class A+ A A+ A
(according to Pdesign kW 2.40 3.40 5.00 6.00
EN14825) SEER 5.63 5.21 5.72 5.51
Annual energy consumption kWh 149 228 306 381
Heating (Average Energy efficiency class A+ A
climate) Pdesign kW 2.60 2.90 4.00 4.60
SCOP/A 4.24 3.88 3.93 3.80
Annual energy consumption kWh 858 1,047 1,425 1,693
Nominal efficiency EER 3.74 2.96 3.03 2.91
COP 4.00 3.48 3.10 3.21
Annual energy consumption kWh 321 574 825 1,030
Energy labeling Directive Cooling/Heating A/A B/A B/D C/C

Indoor unit FDXM 25F3 35F3 50F3 60F3


Dimensions Unit HeightxWidthxDepth mm 200x750x620 200x1,150x620
Weight Unit kg 21 28
Air filter Type Removable / washable
Fan Air flow rate Cooling Low/Medium/High m³/min 7.3/8.0 /8.7 13.3/14.6 /15.8 13.5/14.8 /16.0
Heating Low/Medium/High m³/min 7.3/8.0 /8.7 13.3/14.6 /15.8 13.5/14.8 /16.0
External static pressure Nom. Pa 30 40
Sound power level Cooling dBA 53 55 56
Heating dBA 53 55 56
Sound pressure level Cooling Low/High dBA 27/35 30/38
Heating Low/High dBA 27/35 30/38
Control systems Infrared remote control BRC4C65
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RXS 25L3 35L3 50L 60L


Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300
Weight Unit kg 34 47 48
Sound power level Cooling dBA 59 61 62
Heating dBA 59 61 62
Sound pressure level Cooling Low/High dBA -/46 -/48 44/48 46/49
Heating Low/High dBA -/47 -/48 45/48 46/49
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-410A
GWP 2,087.5
Charge kg/TCO2Eq 1.0/2.1 1.2/2.5 1.7/3.5 1.5/3.1
Piping connections Liquid OD mm 6.35
Gas OD mm 9.5 12.7
Piping OU - IU Max. m 20 30
length System Chargeless m 10 -
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 15 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 1~/50/220-230-240
Current - 50Hz Maximum fuse amps (MFA) A -
Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | Nominal heating capacities are based on:
indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.

66
SKY AIR INTRO
FBA-A + RZQG-L9V1/L(8)Y1

Concealed ceiling unit with


medium ESP

INDOOR
Slimmest yet most powerful medium static pressure unit

UNITS
outblow
on the market

ʯʯ Combination with Seasonal Smart ensures best in class quality, rear


suction
highest efficiency and performance bottom
suction
ʯʯ Slimmest unit in class, only 245mm (300mm built-in height) and FBA-A
therefore narrow ceiling voids are no longer a challenge
ʯʯ Low operation sound level down to 25dBA

OUTDOOR
UNITS
ʯʯ Medium external static pressure up to 150Pa facilitates using
flexible ducts of varying lengths
NEW
ʯʯ Unified indoor unit range for R-32 and R-410A
with
ʯʯ Possibility to change ESP via wired remote control allows multi zoning
optimisation of the supply air volume option
ʯʯ Discretely concealed in the ceiling: only the suction and discharge RZQG100-125-140L9V1/L(8)Y1 BRC1H51W BRP069A81
grilles are visible

AIR CURTAINS
NEW ʯʯ Multi zoning kit allows multiple individually-controlled climate

BIDDLE
zones to be served by one indoor unit ʯʯ Flexible installation: air suction direction can be altered from rear
ʯʯ Reduced energy consumption thanks to specially developed DC to bottom suction and choice between free use or connection to
fan motor optional suction grilles
ʯʯ Optional fresh air intake ʯʯ Standard built-in drain pump with 625mm lift increases flexibility
and installation speed

VENTILATION
71A + 100A + 125A + 140A + 71A + 100A + 125A + 140A +
Efficiency data FBA + RZQG
71L9V1 100L9V1 125L9V1 140L9V1 71L8Y1 100L8Y1 125L8Y1 140LY1
Cooling capacity Nom. kW 6.8 9.5 12.0 13.4 6.8 9.5 12.0 13.4
Heating capacity Nom. kW 7.50 10.80 13.50 15.5 7.50 10.80 13.50 15.5
Power input Cooling Nom. kW 1.89 2.49 3.63 4.00 1.89 2.49 3.63 4.00
Heating Nom. kW 1.87 2.45 3.46 4.31 1.87 2.45 3.46 4.31
Seasonal efficiency Cooling Energy efficiency class A++ A+ A++ - A++ A+ A++ -
(according to Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -

CONTROL
SYSTEMS
EN14825) SEER 6.16 5.87 6.11 - 6.16 5.87 6.11 -
Annual energy consumption kWh 386 566 687 - 386 566 687 -
Heating (Average Energy efficiency class A+ A++ A+ - A+ A++ A+ -
climate) Pdesign kW 6.00 11.30 12.70 - 6.00 11.30 12.70 -
SCOP/A 4.31 4.78 4.28 - 4.31 4.78 4.28 -
Annual energy consumption kWh 1,949 3,310 4,154 - 1,949 3,310 4,154 -
Nominal efficiency EER 3.60 3.81 3.31 3.35 3.60 3.81 3.31 3.35
COP 4.01 4.41 3.90 3.60 4.01 4.41 3.90 3.60
Annual energy consumption kWh 944 1,247 1,813 - 944 1,247 1,813 -

& ACCESSORIES
Energy labeling Directive Cooling/Heating A/A -/- A/A -/-

OPTIONS
Indoor unit FBA 71A 100A 125A 140A 71A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800 245x1,000x800 245x1,400x800
Weight Unit kg 35.0 46.0 35.0 46.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 12.5/15.0 /18.0 23.0/26.0 /29.0 23.5/29.0 /34.0 12.5/15.0 /18.0 23.0/26.0 /29.0 23.5/29.0 /34.0
Heating Low/Medium/High m³/min 12.5/15.0 /18.0 23.0/26.0 /29.0 23.5/29.0 /34.0 12.5/15.0 /18.0 23.0/26.0 /29.0 23.5/29.0 /34.0
External static pressure Nom./High Pa 30/150 40/150 50/150 30/150 40/150 50/150
Sound power level Cooling dBA 56 58 62 56 58 62
Sound pressure level Cooling Low/High dBA 25.0/30.0 30.0/34.0 32.0/37.0 25.0/30.0 30.0/34.0 32.0/37.0
& PLATFORMS

Heating Low/High dBA 25.0/31.0 30.0/36.0 32.0/38.0 25.0/31.0 30.0/36.0 32.0/38.0


Control systems Infrared remote control BRC4C65 / BRC4C66
TOOLS

Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52


Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RZQG 71L9V1 100L9V1 125L9V1 140L9V1 71L8Y1 100L8Y1 125L8Y1 140LY1
Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 69 95 80 101
Sound power level Cooling dBA 64 66 67 69 64 66 67 69
Sound pressure level Cooling Nom. dBA 48 50 51 52 48 50 51 52
Heating Nom. dBA 50 52 53 50 52 53
Operation range Cooling Ambient Min.~Max. °CDB -15~50
TECHNICAL
DRAWINGS

Heating Ambient Min.~Max. °CWB -20~15.5


Refrigerant Type/GWP R-410A/2,087.5
Charge kg/TCO2Eq 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50 75 50 75
length System Equivalent m 70 90 70 90
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
PREVIOUS

Current - 50Hz Maximum fuse amps (MFA) A 25 40 16 25


MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

67
FBA-A + RZQSG-L3/9V1/L(8)Y1

Concealed ceiling unit with


medium ESP
Slimmest yet most powerful medium static pressure unit
outblow
on the market

ʯʯ Combination with Seasonal Classic ensures good value for money rear
suction
for all types of commercial applications bottom
suction
ʯʯ Slimmest unit in class, only 245mm (300mm built-in height) and FBA-A
therefore narrow ceiling voids are no longer a challenge
ʯʯ Low operation sound level down to 25dBA
ʯʯ Medium external static pressure up to 150Pa facilitates using
flexible ducts of varying lengths
NEW
ʯʯ Unified indoor unit range for R-32 and R-410A
with
ʯʯ Possibility to change ESP via wired remote control allows multi zoning
optimisation of the supply air volume option
ʯʯ Discretely concealed in the ceiling: only the suction and discharge RZQSG71-100-125L9V1/L(8)Y1 BRC1H51W BRP069A81
grilles are visible
NEW ʯʯ Multi zoning kit allows multiple individually-controlled climate
zones to be served by one indoor unit
External static pressure (Pa)

Optimised supply air volume Air flow (rated)


Fan characteristic
Automatically selects the most appropriate fan curve to achieve the units’ nominal air flow within ±10% curves

Why? Air flow (actual)

After installation the real ducting will frequently differ from the initially calculated air flow resistance
 the real air flow may be much lower or higher than nominal, leading to a lack of capacity or
uncomfortable air temperature
Air flow (with
Duct resistance
automatic adjustment)
Automatic Airflow Adjustment function will adapt the unit’s fan speed to any ducting automatically curves
(10 or more fan curves are ­available on every model), making installation much faster

±10% Air flow (m3/min)

100A + 125A + 140A + 100A + 125A +


Efficiency data FBA + RZQSG 71A + 71L3V1 140A + 140LY1
100L9V1 125L9V1 140L9V1 100L8Y1 125L8Y1
Cooling capacity Nom. kW 6.80 9.5 12.0 13.4 9.5 12.0 13.4
Heating capacity Nom. kW 7.50 10.80 13.50 15.5 10.80 13.50 15.5
Power input Cooling Nom. kW 1.98 2.84 3.72 4.38 2.84 3.72 4.38
Heating Nom. kW 1.91 2.94 3.72 4.56 2.94 3.72 4.56
Seasonal efficiency Cooling Energy efficiency class A+ A - A+ A -
(according to Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -
EN14825) SEER 5.84 5.61 5.47 - 5.61 5.47 -
Annual energy consumption kWh 408 593 768 - 593 768 -
Heating (Average Energy efficiency class A+ - A+ -
climate) Pdesign kW 6.00 7.60 - 7.60 -
SCOP/A 4.01 4.15 4.01 - 4.15 4.01 -
Annual energy consumption kWh 2,095 2,564 2,653 - 2,564 2,653 -
Nominal efficiency EER 3.43 3.35 3.23 3.06 3.35 3.23 3.06
COP 3.92 3.67 3.63 3.40 3.67 3.63 3.40
Annual energy consumption kWh 991 1,418 1,858 - 1,418 1,858 -
Energy labeling Directive Cooling/Heating A/A -/- A/A -/-
Indoor unit FBA 71A 100A 125A
140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800
Weight Unit kg 35.0 46.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 12.5/15.0 /18.0 23.0/26.0 /29.0 23.5/29.0 /34.0 23.0/26.0 /29.0 23.5/29.0 /34.0
Heating Low/Medium/High m³/min 12.5/15.0 /18.0 23.0/26.0 /29.0 23.5/29.0 /34.0 23.0/26.0 /29.0 23.5/29.0 /34.0
External static pressure Nom./High Pa 30/150 40/150 50/150 40/150 50/150
Sound power level Cooling dBA 56 58 62 58 62
Sound pressure level Cooling Low/High dBA 25.0/30.0 30.0/34.0 32.0/37.0 30.0/34.0 32.0/37.0
Heating Low/High dBA 25.0/31.0 30.0/36.0 32.0/38.0 30.0/36.0 32.0/38.0
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Outdoor unit RZQSG 71L3V1 100L9V1 125L9V1 140L9V1 100L8Y1 125L8Y1 140LY1
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 67 72 74 95 82 101
Sound power level Cooling dBA 65 70 69 70 69
Sound pressure level Cooling Nom./Silent operation dBA 49/47 53/- 54/- 53/- 54/- 53/-
Heating Nom. dBA 51 57 58 54 57 58 54
Operation range Cooling Ambient Min.~Max. °CDB -15.0~46 -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-410A/2,087.5
Charge kg/TCO2Eq 2.75/5.7 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 15 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 - 16 20
MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

68
SKY AIR INTRO
FBA-A + RXS-L(3) Split

Concealed ceiling unit with


medium ESP

INDOOR
Slimmest yet most powerful medium static pressure unit

UNITS
outblow
on the market

ʯʯ Combination with split outdoor units is ideal for small retail, rear
suction
offices or residential applications bottom
suction
ʯʯ Slimmest unit in class, only 245mm (300mm built-in height) and FBA-A
therefore narrow ceiling voids are no longer a challenge
ʯʯ Low operation sound level down to 25dBA

OUTDOOR
UNITS
ʯʯ Medium external static pressure up to 150Pa facilitates using
flexible ducts of varying lengths
NEW
ʯʯ Unified indoor unit range for R-32 and R-410A
with
ʯʯ Possibility to change ESP via wired remote control allows multi zoning
optimisation of the supply air volume option
ʯʯ Discretely concealed in the ceiling: only the suction and discharge RXS35L3 BRC1H51W BRP069A81
grilles are visible

AIR CURTAINS
NEW ʯʯ Multi zoning kit allows multiple individually-controlled climate

BIDDLE
zones to be served by one indoor unit

Efficiency data FBA + RXS 35A + 35L3 50A + 50L 60A + 60L

VENTILATION
Cooling capacity Nom. kW 3.40 5.00 5.70
Heating capacity Nom. kW 4.00 5.50 7.00
Power input Cooling Nom. kW 0.85 1.42 1.65
Heating Nom. kW 1.00 1.44 1.89
Seasonal efficiency Cooling Energy efficiency class A++ A+
(according to Pdesign kW 3.40 5.00 5.70
EN14825) SEER 6.17 6.21 5.86
Annual energy consumption kWh 193 282 340
Heating (Average Energy efficiency class A+
climate) Pdesign kW 2.90 4.40 4.60

CONTROL
SYSTEMS
SCOP/A 4.07 4.06 4.01
Annual energy consumption kWh 998 1,517 1,606
Nominal efficiency EER 3.99 3.52 3.45
COP 4.02 3.83 3.71
Annual energy consumption kWh 426 710 826
Energy labeling Directive Cooling/Heating A/A

Indoor unit FBA 35A 50A 60A


Dimensions Unit HeightxWidthxDepth mm 245x700x800 245x1,000x800

& ACCESSORIES
Weight Unit kg 28.0 35.0

OPTIONS
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 10.5/12.5 /15.0 12.5/15.0 /18.0
Heating Low/Medium/High m³/min 10.5/12.5 /15.0 12.5/15.0 /18.0
External static pressure Nom./High Pa 30/150
Sound power level Cooling dBA 60 56
Sound pressure level Cooling Low/High dBA 29.0/35.0 25.0/30.0
Heating Low/High dBA 29.0/37.0 25.0/31.0
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
& PLATFORMS
TOOLS

Outdoor unit RXS 35L3 50L 60L


Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300
Weight Unit kg 34 47 48
Sound power level Cooling dBA 61 62
Heating dBA 61 62
Sound pressure level Cooling Low/High dBA -/48 44/48 46/49
Heating Low/High dBA -/48 45/48 46/49
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-410A
TECHNICAL
DRAWINGS

GWP 2,087.5
Charge kg/TCO2Eq 1.2/2.5 1.7/3.5 1.5/3.1
Piping connections Liquid OD mm 6.35
Gas OD mm 9.5 12.7
Piping OU - IU Max. m 20 30
length System Chargeless m 10 -
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.020 (for piping length exceeding 10m)
Level difference IU - OU Max. m 15 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 1~/50/220-230-240
PREVIOUS

Current - 50Hz Maximum fuse amps (MFA) A -

69
FDA + RZQG-L9V1/L(8)Y1, RZQSG-L3/L9V1/L(8)Y1

Concealed ceiling unit


with high ESP
ESP up to 200, ideal for large sized spaces
outblow

ʯʯ Unified range for R-32 and R-410A


ʯʯ High external static pressure up to 200Pa facilitates extensive duct rear
suction
and grille network bottom
suction
ʯʯ Possibility to change ESP via wired remote control allows FDA125A
optimisation of the supply air volume
ʯʯ Discretely concealed in the ceiling: only the suction and discharge
grilles are visible
ʯʯ Reduced energy consumption thanks to specially developed DC
fan motor
ʯʯ No optional adapter needed for DIII-connection, link your unit into
the wider building management system.
ʯʯ Flexible installation, as the air suction direction can be altered RZQG100-125-140L9V1/L(8)Y1 BRC1H51W BRP069A81
from rear to bottom suction
ʯʯ Standard built-in drain pump with 625mm lift increases flexibility
and installation speed

FDA125A5VEB / FDA125A5VEB / FDA125A5VEB / FDA125A5VEB /


Efficiency data FDA + RZQG/RZQSG
RZQG125L9V1B RZQG125L8Y1B RZQSG125L9V1B RZQSG125L8Y1B
Cooling capacity Nom. kW 12.0
Heating capacity Nom. kW 13.5
Power input Cooling Nom. kW 3.20 3.74
Heating Nom. kW 3.53 3.85
Seasonal efficiency Cooling Energy efficiency class A+ A
(according to Pdesign kW 12.0
EN14825) SEER 5.81 5.20
Annual energy consumption kWh 723 808
Heating (Average Energy efficiency class A+ A
climate) Pdesign kW 12.7 7.60
SCOP/A 4.21 3.90
Annual energy consumption kWh 4,227 2,729
Nominal efficiency EER 3.75 3.21
COP 3.83 3.51
Annual energy consumption kWh 1,600 (0.000) 1,870 (0.000)
Energy labeling Directive Cooling/Heating A/A A/B

Indoor unit FDA 125A


Dimensions Unit HeightxWidthxDepth mm 300x1,400x700
Required ceiling void > mm 350
Weight Unit kg 45
Decoration panel Model BYBS125DJW1
Colour White (10Y9/0.5)
Dimensions HeightxWidthxDepth mm 55x1,500x500
Weight kg 6.5
Air filter Type Resin net with mold resistance
Fan - Air flow rate Cooling High/Low m³/min 39/28
Heating High/Low m³/min 39/28
Fan - External static pressure High/Nom./Maximum available/High Pa 200/50/-
Sound power level Cooling dBA 66
Sound pressure level Cooling High/Low dBA 40/33
Heating High/Low dBA 40/33
Refrigerant Type R-32 / R-410A
Control systems Infrared remote control BRC4C65
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

Outdoor unit RZQG/RZQSG RZQG125L9V1 RZQG125L8Y1 RZQSG125L9V1 RZQSG125L8Y1


Dimensions Unit HeightxWidthxDepth mm 1,430x940x320 990x940x320
Weight Unit kg 95 101 74 82
Sound power level Cooling dBA 67 70
Sound pressure level Cooling Nom. dBA 51 54/-
Heating Nom. dBA 53 58
Operation range Cooling Ambient Min.~Max. °CDB -15~50 -15~46
Heating Ambient Min.~Max. °CWB -20~15.5 -15~15.5
Refrigerant Type/GWP R-410A/2,087.5
Charge kg/TCO2Eq 4.0/8.4 2.9/6.1
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 75 50
length System Equivalent m 90 70
Chargeless m 30 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 40 25 32 16
(1) EER/COP according to Eurovent 2012, for use outside EU only
(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.
70
SKY AIR INTRO
FDQ-B + RZQ-C

Concealed ceiling unit with


high ESP

INDOOR
ESP up to 250, ideal for extra large sized spaces

UNITS
›› High external static pressure up to 250Pa facilitates using flexible
ducts of varying lengths
›› Discretely concealed in the ceiling: only the suction and discharge
grilles are visible FDQ-B
›› Up to 26.4kW in heating mode

OUTDOOR
UNITS
BRC1H51W

AIR CURTAINS
BIDDLE
VENTILATION
CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS

Indoor unit FDQ 200B 250B


Dimensions Unit HeightxWidthxDepth mm 450x1,400x900
Required ceiling void > mm 450
TECHNICAL
DRAWINGS

Weight Unit kg 89.0 94.0


Air filter Type Resin net with mold resistance
Fan - Air flow rate Cooling Nom. m³/min 69.0 89.0
Heating Nom. m³/min 69.0 89.0
Fan - External static High/Nom./Low Pa
250/250/250
pressure
Sound power level Cooling dBA 81 82
Sound pressure level Cooling High dBA 45.0 47.0
Heating Low dBA 45.0 47.0
PREVIOUS

Control systems Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 230

71
ADEQ-C + ARXS-L/AZQS-B(8)V1

Concealed ceiling unit


Ideal for residential applications with false ceilings

ʯʯ Energy efficient units: up to class A energy labels


ʯʯ Medium external static pressure up to 150Pa facilitates using outblow
flexible ducts of varying lengths
ʯʯ Slim indoor unit (300mm built-in height) suited for narrow ceiling rear
suction
installation bottom
suction
ʯʯ Exclusively offered for pair applications ADEQ-C
ʯʯ Discretely concealed in the ceiling: only the suction and discharge
grilles are visible
ʯʯ Flexible installation: air suction direction can be altered from rear
to bottom suction and choice between free use or connection to
optional suction grilles
ʯʯ Drain pump kit available as accessory

AZQS140B8V1 BRC1D52 BRC4C65 BRP069A81

Efficiency data ADEQ + ARXS/AZQS ADEQ71C + ARXS71L ADEQ100C + AZQS100B8V1 ADEQ125C + AZQS125B8V1
Cooling capacity Nom. kW 6.80 9.50 12.1
Heating capacity Nom. kW 7.50 10.8 13.5
Power input Cooling Nom. kW 2.55 - -
Heating Nom. kW 2.16 - -
Seasonal efficiency Cooling Energy efficiency class A A -
(according to Pdesign kW 6.80 9.50 -
EN14825) SEER 5.30 5.10 -
Annual energy consumption kWh 449 652 -
Heating (Average Energy efficiency class A A -
climate) Pdesign kW 6.00 7.60 -
SCOP/A 3.80 3.81 -
Annual energy consumption kWh 2,210 2,793 -

Indoor unit ADEQ 71C 100C 125C


Dimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800
Weight Unit kg 35 46
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 12.5/15.0 /18.0 23.0/26.0 /29.0 23.5/29.0 /34.0
Heating Low/Medium/High m³/min 12.5/15.0 /18.0 23.0/26.0 /29.0 23.5/29.0 /34.0
External static pressure Nom./High Pa 30/150 40/150 50/150
Sound power level Cooling dBA 56 58 62
Sound pressure level Cooling Low/Nom./High dBA 25/30/30 30/34/34 32/37/37
Heating Low/Nom./High dBA 25/31/31 30/36/36 32/38/38
Control systems Infrared remote control BRC4C65
Wired remote control BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit ARXS/AZQS ARXS71L AZQS100B8V1 AZQS125B8V1


Dimensions Unit HeightxWidthxDepth mm 735x825x300 990x940x320
Weight Unit kg 47 72.8 74.3
Sound power level Cooling dBA 65 70 71
Heating dBA 65
Sound pressure level Cooling Nom. dBA 52 53 54
Heating Nom. dBA 52 57 58
Operation range Cooling Ambient Min.~Max. °CDB -10~46 -5~46
Heating Ambient Min.~Max. °CWB -15~18 -15~15.5
Refrigerant Type R-410A
GWP 2,087.5
Charge kg/TCO2Eq 1.70/- 2.9/6.1
Piping connections Liquid OD mm 9.52 9.52
Gas OD mm 15.9 15.9
Piping OU - IU Max. m 30 50
length System Equivalent m 70
Chargeless m 10 30
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) See installation manual
Level difference IU - OU Max. m 20.0 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-230-240 1~/50/220-240
Current - 50Hz Maximum fuse amps (MFA) A -

72
SKY AIR INTRO
ABQ-C + AZQS-B(8)V1/BY1

Concealed ceiling unit


Ideal for medium sized shops with false ceilings

INDOOR
UNITS
›› Ideal solution for busy retail and business environments and small
shops
›› Discretely concealed in the ceiling: only the suction and discharge
grilles are visible
›› Exclusively offered for pair applications
›› Air filter removes airborne dust particles to ensure a steady supply ABQ-C
of clean air
›› Easy installation and maintenance

OUTDOOR
UNITS
›› Double protection drainage system ensures quality

AZQS100-125B8V1/BY1 ARCWB

AIR CURTAINS
BIDDLE
Efficiency data ABQ + AZQS 140C + 140B8V1 100C + 100BY1 125C + 125BY1 140C + 140BY1
Cooling capacity Nom. kW 13.0 9.5 12.1 13.0
Heating capacity Nom. kW 15.5 10.8 13.5 15.5
Power input Cooling Nom. kW 4.32 3.63 4.31 4.32

VENTILATION
Heating Nom. kW 4.55 3.16 3.96 4.55
Seasonal efficiency Cooling Energy label - B -
(according to Pdesign kW - 9.50 -
EN14825) SEER - 4.65 -
Annual energy consumption kWh - 716 -
Heating (Average Energy label - A -
climate) Pdesign kW - 6.78 -
SCOP - 3.80 -
Annual energy consumption kWh - 2,498 -
Nominal efficiency EER 3.01 2.62 2.81 3.01

CONTROL
SYSTEMS
COP 3.41 3.42 3.41
Annual energy consumption kWh - 1,813 2,153 -
Energy label Cooling/Heating - D/B C/B -

Indoor unit ABQ 140C 100C 125C 140C


Dimensions Unit HeightxWidthxDepth mm 378x541x1,499 378x541x1,045 378x541x1,299 378x541x1,499
Weight Unit kg 56 44 50 56
Air filter Type
Fan - Air flow rate Cooling High/Nom./Low m³/min 48.7/43.9/37.9 22.7/20.5/18.3 40.5/37.4/34.8 48.7/43.9/37.9

& ACCESSORIES
Heating High/Nom./Low m³/min 48.7/43.9/37.9 22.7/20.5/18.3 40.5/37.4/34.8 48.7/43.9/37.9

OPTIONS
Fan - External static High/Nom./Low Pa
150/122/92 70/57/45 150/128/111 150/122/92
pressure
Sound power level Cooling dBA - 60 -
Heating dBA - 60 -
Sound pressure level Cooling High/Nom./Low dBA 55/53/50 41/38/36 53/52/50 55/53/50
Heating High/Nom./Low dBA 55/53/50 41/38/36 53/52/50 55/53/50
Control systems Wired remote control ARCWB
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240
& PLATFORMS

Outdoor unit AZQS 140B8V1 100BY1 125BY1 140BY1


TOOLS

Dimensions Unit HeightxWidthxDepth mm 1,430x940x320 990x940x320 1,430x940x320


Weight Unit kg 94.9 82 101
Sound power level Cooling dBA 70 71 70
Sound pressure level Cooling Nom. dBA 53 54 53
Heating Nom. dBA 54 57 58 54
Night quiet mode Level 1 dBA 49
Operation range Cooling Ambient Min.~Max. °CDB -5~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/Charge kg-TCO²Eq/GWP R-410A/4.0/8.4/2,087.5 R-410A/2.9/6.1/2,087.5 R-410A/4.0/8.4/2,087.5
Piping connections Liquid OD mm 9.52
TECHNICAL
DRAWINGS

Gas OD mm 15.9
Piping length OU - IU Max. m 50
System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3N~ / 50 / 380-415
Current - 50Hz Maximum fuse amps (MFA) A 40 16 20 25
PREVIOUS

(1) EER/COP according to Eurovent 2012, for use outside EU only (2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information
on each combination, please refer to the electrical data drawing.

73
74
SKY AIR INTRO
FAA-A + RZQG-L9V1/L(8)Y1

Wall mounted unit


For rooms with no false ceilings nor free floor space

INDOOR
UNITS
ʯʯ Combination with Seasonal Smart ensures best in class quality,
highest efficiency and performance
ʯʯ Flat, stylish front panel blends easily within any interior décor and
is easier to clean
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified indoor unit range for R-32 and R-410A FAA-A
ʯʯ Reduced energy consumption thanks to specially developed DC
fan motor

OUTDOOR
UNITS
ʯʯ The air is comfortably spread up- and downwards thanks to
5 different discharge angles that can be programmed via the
remote control
ʯʯ Maintenance operations can be performed easily from the front of
the unit
ʯʯ Flexible to install as the largest casing only weighs 17kg and piping RZQG100-125-140L9V1/L(8)Y1 BRC1H51W BRP069A81
connection can be done at the bottom, left or right of the unit

AIR CURTAINS
BIDDLE
VENTILATION
Efficiency data FAA + RZQG 71A + 71L9V1 100A + 100L9V1 71A + 71L8Y1 100A + 100L8Y1
Cooling capacity Nom. kW 6.80 9.50 6.80 9.50
Heating capacity Nom. kW 7.50 10.8 7.50 10.8
Power input Cooling Nom. kW 2.00 2.63 2.00 2.63
Heating Nom. kW 2.03 3.00 2.03 3.00
Seasonal efficiency Cooling Energy efficiency class A++
(according to Pdesign kW 6.80 9.50 6.80 9.50
EN14825) SEER 6.43 6.11 6.43 6.11

CONTROL
SYSTEMS
Annual energy consumption kWh 371 545 371 545
Heating (Average Energy efficiency class A+
climate) Pdesign kW 6.33 10.2 6.33 10.2
SCOP/A 4.02 4.01 4.02 4.01
Annual energy consumption kWh 2,205 3,562 2,205 3,562
Nominal efficiency EER 3.40 3.62 3.40 3.62
COP 3.70 3.61 3.70 3.61
Annual energy consumption kWh 1,000 1,315 1,000 1,315
Energy labeling Directive Cooling/Heating A/A

& ACCESSORIES
OPTIONS
Indoor unit FAA 71A 100A 71A 100A
Dimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240 290x1,050x238 340x1,200x240
Weight Unit kg 13.0 17.0 13.0 17.0
Air filter Type -
Fan Air flow rate Cooling Low/Medium/High m³/min 14.0/16 /18.0 19.0/23 /26.0 14.0/16 /18.0 19.0/23 /26.0
Heating Low/Medium/High m³/min 14.0/16.0 /18.0 19.0/23.0 /26.0 14.0/16.0 /18.0 19.0/23.0 /26.0
Sound power level Cooling dBA 61 65 61 65
Heating dBA 61 65 61 65
Sound pressure level Cooling Low/High dBA 40/45 41/49 40/45 41/49
Heating Low/High dBA 40/45 41/49 40/45 41/49
& PLATFORMS

Control systems Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
TOOLS

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RZQG 71L9V1 100L9V1 71L8Y1 100L8Y1


Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 69 95 80 101
Sound power level Cooling dBA 64 66 64 66
Sound pressure level Cooling Nom. dBA 48 50 48 50
Heating Nom. dBA 50 52 50 52
Operation range Cooling Ambient Min.~Max. °CDB -15~50
Heating Ambient Min.~Max. °CWB -20~15.5
TECHNICAL
DRAWINGS

Refrigerant Type/GWP R-410A/2,087.5


Charge kg/TCO2Eq 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50 75 50 75
length System Equivalent m 70 90 70 90
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
PREVIOUS

Current - 50Hz Maximum fuse amps (MFA) A 25 40 16 25


MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

75
FAA-A + RZQSG-L3/9V1/L(8)Y1

Wall mounted unit


For rooms with no false ceilings nor free floor space

ʯʯ Combination with Seasonal Classic ensures good value for money


for all types of commercial applications.
ʯʯ Flat, stylish front panel blends easily within any interior décor and
is easier to clean
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified indoor unit range for R-32 and R-410A FAA-A

RZQSG-L3/9V1,L(8)Y1 BRC1H51W BRP069A81

Efficiency data FAA + RZQSG 71A + 71L3V1 100A + 100L9V1 100A + 100L8Y1
Cooling capacity Nom. kW 6.80 9.50
Heating capacity Nom. kW 7.50 10.8
Power input Cooling Nom. kW 2.12 3.16
Heating Nom. kW 2.08 3.17
Seasonal efficiency Cooling Energy efficiency class A+
(according to Pdesign kW 6.80 9.50
EN14825) SEER 6.05 5.61
Annual energy consumption kWh 394 593
Heating (Average Energy efficiency class A A+
climate) Pdesign kW 6.33 6.81
SCOP/A 3.90 4.01
Annual energy consumption kWh 2,155 2,378
Nominal efficiency EER 3.21 3.01
COP 3.61 3.41
Annual energy consumption kWh 1,059 1,580
Energy labeling Directive Cooling/Heating A/A B/B

Indoor unit FAA 71A 100A 100A


Dimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240
Weight Unit kg 13.0 17.0
Air filter Type -
Fan Air flow rate Cooling Low/Medium/High m³/min 14.0/16 /18.0 19.0/23 /26.0
Heating Low/Medium/High m³/min 14.0/16.0 /18.0 19.0/23.0 /26.0
Sound power level Cooling dBA 61 65
Heating dBA 61 65
Sound pressure level Cooling Low/High dBA 40/45 41/49
Heating Low/High dBA 40/45 41/49
Control systems Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RZQSG 71L3V1 100L9V1 100L8Y1


Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 67 72 82
Sound power level Cooling dBA 65 70 69
Sound pressure level Cooling Nom./Silent operation dBA 49/47 53/-
Heating Nom. dBA 51 57
Operation range Cooling Ambient Min.~Max. °CDB -15.0~46 -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-410A/2,087.5
Charge kg/TCO2Eq 2.75/5.7 2.9/6.1
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 15 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16
MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing. |
Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | Nominal
heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series

76
SKY AIR INTRO
FHA-A + RZQG-L9V1/L(8)Y1

Ceiling suspended unit


For wide rooms with no false ceilings nor free floor space

INDOOR
UNITS
ʯʯ Combination with Seasonal Smart ensures best in class quality,
highest efficiency and performance
ʯʯ Ideal for comfortable air flow in wide rooms thanks to Coanda
effect: up to 100° discharge angle
ʯʯ Even rooms with ceilings up to 3.8m can be heated up or cooled
down very easily without capacity loss FHA-A
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified indoor unit range for R-32 and R-410A

OUTDOOR
UNITS
ʯʯ Can easily be mounted in corners and narrow spaces, as it only
needs 30mm lateral service space
ʯʯ Reduced energy consumption thanks to specially developed small
tube heat exchanger, DC fan motor and drain pump
ʯʯ 5 different fan speeds available for maximum comfort
ʯʯ Stylish unit blends easily with any interior. The flaps close entirely RZQG100-125-140L9V1/L(8)Y1 BRC1H51W BRP069A81
when the unit is not operating and there are no air intake grilles

AIR CURTAINS
visible

BIDDLE
VENTILATION
71A + 100A + 125A + 140A + 71A + 100A + 125A + 140A +
Efficiency data FHA + RZQG
71L9V1 100L9V1 125L9V1 140L9V1 71L8Y1 100L8Y1 125L8Y1 140LY1
Cooling capacity Nom. kW 6.8 9.5 12.0 13.4 6.8 9.5 12.0 13.4
Heating capacity Nom. kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50
Power input Cooling Nom. kW 1.78 2.49 3.58 4.05 1.78 2.49 3.58 4.05
Heating Nom. kW 1.82 2.61 3.48 4.27 1.82 2.60 3.48 4.27
Seasonal efficiency Cooling Energy efficiency class A++ A+ - A++ A+ -
(according to Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -
EN14825) SEER 6.86 6.11 6.01 - 6.86 6.11 6.01 -

CONTROL
SYSTEMS
Annual energy consumption kWh 347 545 699 - 347 545 699 -
Heating (Average Energy efficiency class A+ A++ A+ - A+ A++ A+ -
climate) Pdesign kW 7.60 11.30 14.13 - 7.60 11.30 14.13 -
SCOP/A 4.32 4.61 4.23 - 4.32 4.61 4.23 -
Annual energy consumption kWh 2,463 3,432 4,677 - 2,463 3,432 4,677 -
Nominal efficiency EER 3.82 3.81 3.35 3.31 3.82 3.81 3.35 3.31
COP 4.13 4.15 3.89 3.63 4.13 4.15 3.89 3.63
Annual energy consumption kWh 890 1,245 1,790 2,025 890 1,245 1,790 2,025
Energy labeling Directive Cooling/Heating A/A

& ACCESSORIES
OPTIONS
Indoor unit FHA 71A 100A 125A 140A 71A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690 235x1,270x690 235x1,590x690
Weight Unit kg 32.0 38.0 32.0 38.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 14.0/17.0 /20.5 20.0/24.0 /28.0 23.0/27.0 /31.0 24.0/29.0 /34.0 14.0/17.0 /20.5 20.0/24.0 /28.0 23.0/27.0 /31.0 24.0/29.0 /34.0
Heating Low/Medium/High m³/min 14.0/17.0 /20.5 20.0/24.0 /28.0 23.0/27.0 /31.0 24.0/29.0 /34.0 14.0/17.0 /20.5 20.0/24.0 /28.0 23.0/27.0 /31.0 24.0/29.0 /34.0
Sound power level Cooling dBA 55 60 62 64 55 60 62 64
Sound pressure level Cooling Low/High dBA 34/38 34/42 37/44 38/46 34/38 34/42 37/44 38/46
Heating Nom./High dBA 36/38 38/42 41/44 42/46 36/38 38/42 41/44 42/46
Control systems Infrared remote control BRC7GA53 / BRC7GA56
& PLATFORMS

Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52


TOOLS

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RZQG 71L9V1 100L9V1 125L9V1 140L9V1 71L8Y1 100L8Y1 125L8Y1 140LY1
Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 69 95 80 101
Sound power level Cooling dBA 64 66 67 69 64 66 67 69
Sound pressure level Cooling Nom. dBA 48 50 51 52 48 50 51 52
Heating Nom. dBA 50 52 53 50 52 53
Operation range Cooling Ambient Min.~Max. °CDB -15~50
Heating Ambient Min.~Max. °CWB -20~15.5
TECHNICAL
DRAWINGS

Refrigerant Type/GWP R-410A/2,087.5


Charge kg/TCO2Eq 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50 75 50 75
length System Equivalent m 70 90 70 90
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
PREVIOUS

Current - 50Hz Maximum fuse amps (MFA) A 25 40 16 25


MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

77
FHA-A + RZQSG-L3/9V1/L(8)Y1

Ceiling suspended unit


For wide rooms with no false ceilings nor free floor space

ʯʯ Combination with Seasonal Classic ensures good value for money


for all types of commercial applications.
ʯʯ Ideal for comfortable air flow in wide rooms thanks to Coanda
effect: up to 100° discharge angle
ʯʯ Even rooms with ceilings up to 3.8m can be heated up or cooled
down very easily without capacity loss FHA-A
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified indoor unit range for R-32 and R-410A

RZQSG71-125L3/9V1/L(8)Y1 BRC1H51W BRP069A81

100A + 125A + 140A + 100A + 125A +


Efficiency data FHA + RZQSG 71A + 71L3V1 140A + 140LY1
100L9V1 125L9V1 140L9V1 100L8Y1 125L8Y1
Cooling capacity Nom. kW 6.8 9.5 12.0 13.4 9.5 12.0 13.4
Heating capacity Nom. kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50
Power input Cooling Nom. kW 1.97 2.96 4.15 4.45 2.96 4.15 4.45
Heating Nom. kW 1.88 2.99 3.73 4.54 2.99 3.73 4.54
Seasonal efficiency Cooling Energy efficiency class A+ - A+ -
(according to Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -
EN14825) SEER 5.61 - 5.61 -
Annual energy consumption kWh 425 593 749 - 593 749 -
Heating (Average Energy efficiency class A A+ - A A+ -
climate) Pdesign kW 7.60 - 7.60 -
SCOP/A 3.90 3.91 4.01 - 3.91 4.01 -
Annual energy consumption kWh 2,727 2,722 2,654 - 2,722 2,654 -
Nominal efficiency EER 3.46 3.21 2.89 3.01 3.21 2.89 3.01
COP 4.00 3.61 3.62 3.41 3.61 3.62 3.41
Annual energy consumption kWh 983 1,480 2,075 2,225 1,480 2,075 2,225
Energy labeling Directive Cooling/Heating A/A C/A B/B A/A C/A B/B

Indoor unit FHA 71A 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690
Weight Unit kg 32.0 38.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 14.0/17.0 /20.5 20.0/24.0 /28.0 23.0/27.0 /31.0 24.0/29.0 /34.0 20.0/24.0 /28.0 23.0/27.0 /31.0 24.0/29.0 /34.0
Heating Low/Medium/High m³/min 14.0/17.0 /20.5 20.0/24.0 /28.0 23.0/27.0 /31.0 24.0/29.0 /34.0 20.0/24.0 /28.0 23.0/27.0 /31.0 24.0/29.0 /34.0
Sound power level Cooling dBA 55 60 62 64 60 62 64
Sound pressure level Cooling Low/High dBA 34/38 34/42 37/44 38/46 34/42 37/44 38/46
Heating Nom./High dBA 36/38 38/42 41/44 42/46 38/42 41/44 42/46
Control systems Infrared remote control BRC7GA53 / BRC7GA56
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RZQSG 71L3V1 100L9V1 125L9V1 140L9V1 100L8Y1 125L8Y1 140LY1
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 67 72 74 95 82 101
Sound power level Cooling dBA 65 70 69 70 69
Sound pressure level Cooling Nom./Silent operation dBA 49/47 53/- 54/- 53/- 54/- 53/-
Heating Nom. dBA 51 57 58 54 57 58 54
Operation range Cooling Ambient Min.~Max. °CDB -15.0~46 -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-410A/2,087.5
Charge kg/TCO2Eq 2.75/5.7 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 15 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 - 16 20
MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing. |
Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | Nominal
heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series

78
SKY AIR INTRO
FHA-A + RXS-L(3) Split

Ceiling suspended unit


For wide rooms with no false ceilings nor free floor space

INDOOR
UNITS
ʯʯ Combination with split outdoor units is ideal for small retail,
offices or residential applications
ʯʯ Ideal for comfortable air flow in wide rooms thanks to Coanda
effect: up to 100° discharge angle
ʯʯ Even rooms with ceilings up to 3.8m can be heated up or cooled
down very easily without capacity loss FHA-A
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified indoor unit range for R-32 and R-410A

OUTDOOR
UNITS
RXS-L(3) BRC1H51W BRP069A81

AIR CURTAINS
BIDDLE
VENTILATION
Efficiency data FHA + RXS 35A + 35L3 50A + 50L 60A + 60L
Cooling capacity Nom. kW 3.40 5.00 5.70
Heating capacity Nom. kW 4.00 6.00 7.20
Power input Cooling Nom. kW 0.92 1.53 1.72
Heating Nom. kW 0.98 1.79 2.17
Seasonal efficiency Cooling Energy efficiency class A++ A+
(according to Pdesign kW 3.40 5.00 5.70
EN14825) SEER 6.18 5.87 6.02
Annual energy consumption kWh 193 298 332
Heating (Average Energy efficiency class A+ A

CONTROL
climate)

SYSTEMS
Pdesign kW 3.10 4.35 4.71
SCOP/A 4.43 3.86 3.87
Annual energy consumption kWh 981 1,578 1,705
Nominal efficiency EER 3.70 3.27 3.31
COP 4.08 3.35 3.32
Annual energy consumption kWh 459 765 861
Energy labeling Directive Cooling/Heating A/A A/C

Indoor unit FHA 35A 50A 60A

& ACCESSORIES
Dimensions Unit HeightxWidthxDepth mm 235x960x690 235x960x690 235x1,270x690

OPTIONS
Weight Unit kg 24.0 25.0 31.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 10.0/11.5 /14.0 10.0/12.0 /15.0 11.5/15.0 /19.5
Heating Low/Medium/High m³/min 10.0/11.5 /14.0 10.0/12.0 /15.0 11.5/15.0 /19.5
Sound power level Cooling dBA 53 54
Sound pressure level Cooling Low/High dBA 31/36 32/37 33/37
Heating Nom./High dBA 34/36 35/37
Control systems Infrared remote control BRC7GA53 / BRC7GA56
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
& PLATFORMS
TOOLS

Outdoor unit RXS 35L3 50L 60L


Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300
Weight Unit kg 34 47 48
Sound power level Cooling dBA 61 62
Heating dBA 61 62
Sound pressure level Cooling Low/High dBA -/48 44/48 46/49
Heating Low/High dBA -/48 45/48 46/49
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-410A
TECHNICAL
DRAWINGS

GWP 2,087.5
Charge kg/TCO2Eq 1.2/2.5 1.7/3.5 1.5/3.1
Piping connections Liquid OD mm 6.35
Gas OD mm 9.5 12.7
Piping OU - IU Max. m 20 30
length System Chargeless m 10 -
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.020 (for piping length exceeding 10m)
Level difference IU - OU Max. m 15 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 1~/50/220-230-240
PREVIOUS

Current - 50Hz Maximum fuse amps (MFA) A -

79
AHQ-C + AZQS-B(8)V1/BY1

Ceiling suspended unit


For wide rooms with no false ceilings nor free floor space

›› Ideal solution for commercial spaces with no or narrow false


ceilings
›› Exclusively offered for pair applications
›› Can easily be installed in both new and refurbishment projects
›› Air filter removes airborne dust particles to ensure a steady supply
of clean air AHQ-C
›› Decrease of temperature variation by automatic fan speed
selection or freely selectable 3-step fan speed.
›› Easy installation and maintenance

AZQS71BV1 ARCWLA

100C + 125C + 140C +


Efficiency data AHQ + AZQS 71C + 71BV1 100C + 100BY1 125C + 125BY1 140C + 140BY1
100B8V1 125B8V1 140B8V1
Cooling capacity Nom. kW 6.8 9.5 12.1 13.0 9.5 12.1 13.0
Heating capacity Nom. kW 7.5 10.8 13.5 15.5 10.8 13.5 15.5
Power input Cooling Nom. kW 2.24 3.62 4.60 4.32 3.62 4.60 4.32
Heating Nom. kW 2.46 3.17 3.74 4.55 3.17 3.74 4.55
Seasonal efficiency Cooling Energy label B - B -
(according to Pdesign kW 6.80 9.50 - 9.50 -
EN14825) SEER 4.65 4.60 - 4.60 -
Annual energy consumption kWh 511.85 723 - 723 -
Heating (Average Energy label A - A -
climate) Pdesign kW 6.33 7.60 - 7.60 -
SCOP 3.80 - 3.80 -
Annual energy consumption kWh 2,332.26 2,800 - 2,800 -
Nominal efficiency EER 3.03 2.62 2.63 3.01 2.62 2.63 3.01
COP 3.05 3.41 3.61 3.41 3.61 3.41
Annual energy consumption kWh 1,120 1,810 2,300 - 1,810 2,300 -
Energy label Cooling/Heating B/D D/B D/A - D/B D/A -

Indoor unit AHQ 71C 100C 125C 140C 100C 125C 140C
Dimensions Unit HeightxWidthxDepth mm 260x1,320x634 260x1,538x634 260x1,786x634 285x1,902x680 260x1,538x634 260x1,786x634 285x1,902x680
Weight Unit kg 38 45 54 70 45 54 70
Air filter Type Removable / washable
Fan - Air flow rate Cooling High/Nom./Low m³/min 23.8/21.3/18.9 31.1/27.8/24.8 34.4/30.6/27.2 43.9/39.1/28.3 31.1/27.8/24.8 34.4/30.6/27.2 43.9/39.1/28.3
Heating High/Nom./Low m³/min 23.8/21.3/18.9 31.1/27.8/24.8 34.4/30.6/27.2 43.9/39.1/28.3 31.1/27.8/24.8 34.4/30.6/27.2 43.9/39.1/28.3
Sound power level Cooling dBA 59 64 69 70 64 69 70
Heating dBA 62 64 69 70 64 69 70
Sound pressure level Cooling High/Nom./Low dBA 49/48/46 52/47/46 52/50/49 56/53/46 52/47/46 52/50/49 56/53/46
Heating High/Nom./Low dBA 49/48/46 52/47/46 52/50/49 56/53/46 52/47/46 52/50/49 56/53/46
Control systems Infrared remote control ARCWLA
Wired remote control ARCWB
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

Outdoor unit AZQS 71BV1 100B8V1 125B8V1 140B8V1 100BY1 125BY1 140BY1
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 67 72.8 74.3 94.9 82 101
Sound power level Cooling dBA 64 70 71 70 71 70
Sound pressure level Cooling Nom. dBA 48 53 54 53 54 53
Heating Nom. dBA 50 57 58 54 57 58 54
Night quiet mode Level 1 dBA 43 49
Operation range Cooling Ambient Min.~Max. °CDB -5~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/Charge kg-TCO²Eq/GWP R-410A/2.75/5.7/2,087.5 R-410A/2.9/6.1/2,087.5 R-410A/4.0/8.4/2,087.5 R-410A/2.9/6.1/2,087.5 R-410A/4.0/8.4/2,087.5
Piping connections Liquid OD mm 9.52
Gas OD mm 15.9
Piping length OU - IU Max. m 50
System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3N~ / 50 / 380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16 20

(1) EER/COP according to Eurovent 2012, for use outside EU only (2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information
on each combination, please refer to the electrical data drawing.

80
81
TECHNICAL TOOLS OPTIONS CONTROL BIDDLE OUTDOOR INDOOR
PREVIOUS VENTILATION SKY AIR INTRO
DRAWINGS & PLATFORMS & ACCESSORIES SYSTEMS AIR CURTAINS UNITS UNITS
FUA-A + RZQG-L9V1/L(8)Y1

4-way blow ceiling suspended


unit
Unique Daikin unit for high rooms with no false ceilings
nor free floor space

ʯʯ Combination with Seasonal Smart ensures best in class quality,


highest efficiency and performance
ʯʯ Even rooms with ceilings up to 3.5m can be heated up or cooled FUA-A
down very easily without capacity loss
ʯʯ Can easily be installed in both new and refurbishment projects
ʯʯ Unified range for R-32 and R-410A
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
ʯʯ Stylish modern casing finished in pure white (RAL9010) and iron
grey (RAL7011) blends easily with any interior
ʯʯ Optimum comfort guaranteed with automatic air flow adjustment RZQG100-125-140L9V1/L(8)Y1 BRC1H51W BRP069A81
to the required load
ʯʯ 5 different discharge angles between 0 and 60°can be
programmed via the remote control
ʯʯ Standard drain pump with 500mm lift increases flexibility and
installation speed

Efficiency data FUA + RZQG 71A + 71L9V1 100A + 100L9V1 125A + 125L9V1 71A + 71L8Y1 100A + 100L8Y1 125A + 125L8Y1
Cooling capacity Nom. kW 6.80 9.50 12.0 6.80 9.50 12.0
Heating capacity Nom. kW 7.50 10.8 13.5 7.50 10.8 13.5
Power input Cooling Nom. kW 1.68 2.46 3.54 1.68 2.46 3.54
Heating Nom. kW 1.84 2.73 3.95 1.84 2.73 3.95
Seasonal efficiency Cooling Energy efficiency class A++ A+ A++ A+
(according to Pdesign kW 6.80 9.50 12.0 6.80 9.50 12.0
EN14825) SEER 6.42 6.11 5.61 6.42 6.11 5.61
Annual energy consumption kWh 371 545 749 371 545 749
Heating (Average Energy efficiency class A+
climate) Pdesign kW 7.60 11.3 14.1 7.60 11.3 14.1
SCOP/A 4.20 4.50 4.44 4.20 4.50 4.44
Annual energy consumption kWh 2,534 3,516 4,456 2,534 3,516 4,456
Nominal efficiency EER 4.05 3.86 3.39 4.05 3.86 3.39
COP 4.08 3.95 3.42 4.08 3.95 3.42
Annual energy consumption kWh 840 1,230 1,770 840 1,230 1,770
Energy labeling Directive Cooling/Heating A/A A/B A/A A/B

Indoor unit FUA 71A 100A 125A 71A 100A 125A


Dimensions Unit HeightxWidthxDepth mm 198x950x950
Weight Unit kg 25.0 26.0 25.0 26.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 16.0/19.5 /23.0 20.0/25.5 /31.0 20.5/26.5 /32.5 16.0/19.5 /23.0 20.0/25.5 /31.0 20.5/26.5 /32.5
Heating Low/Medium/High m³/min 16.0/19.5 /23.0 20.0/25.5 /31.0 20.5/26.5 /32.5 16.0/19.5 /23.0 20.0/25.5 /31.0 20.5/26.5 /32.5
Sound power level Cooling dBA 59 64 65 59 64 65
Heating dBA 59 64 65 59 64 65
Sound pressure level Cooling Low/High dBA 35/41 39/46 40/47 35/41 39/46 40/47
Heating Low/High dBA 35/41 39/46 40/47 35/41 39/46 40/47
Control systems Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/ 50/60 / 220-240/220

Outdoor unit RZQG 71L9V1 100L9V1 125L9V1 71L8Y1 100L8Y1 125L8Y1


Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 69 95 80 101
Sound power level Cooling dBA 64 66 67 64 66 67
Sound pressure level Cooling Nom. dBA 48 50 51 48 50 51
Heating Nom. dBA 50 52 53 50 52 53
Operation range Cooling Ambient Min.~Max. °CDB -15~50
Heating Ambient Min.~Max. °CWB -20~15.5
Refrigerant Type/GWP R-410A/2,087.5
Charge kg/TCO2Eq 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50 75 50 75
length System Equivalent m 70 90 70 90
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 25 40 16 25
MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

82
SKY AIR INTRO
FUA-A + RZQSG-L3/9V1/L(8)Y1

4-way blow ceiling suspended


unit

INDOOR
Unique Daikin unit for high rooms with no false ceilings

UNITS
nor free floor space

ʯʯ Combination with Seasonal Classic ensures good value for money


for all types of commercial applications.
ʯʯ Even rooms with ceilings up to 3.5m can be heated up or cooled FUA-A
down very easily without capacity loss
ʯʯ Can easily be installed in both new and refurbishment projects

OUTDOOR
UNITS
ʯʯ Unified range for R-32 and R-410A
ʯʯ Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
ʯʯ 5 different discharge angles between 0 and 60°can be
programmed via the remote control
RZQSG-L3/9V1/L(8)Y1 BRC1H51W BRP069A81

AIR CURTAINS
BIDDLE
VENTILATION
Efficiency data FUA + RZQSG 71A + 71L3V1 100A + 100L9V1 125A + 125L9V1 100A + 100L8Y1 125A + 125L8Y1
Cooling capacity Nom. kW 6.80 9.50 12.0 9.50 12.0
Heating capacity Nom. kW 7.50 10.8 13.5 10.8 13.5
Power input Cooling Nom. kW 2.12 2.96 4.53 2.96 4.53
Heating Nom. kW 2.08 2.99 3.95 2.99 3.95
Seasonal efficiency Cooling Energy efficiency class A+ A A+ A
(according to Pdesign kW 6.80 9.50 12.0 9.50 12.0
EN14825) SEER 5.81 5.61 5.30 5.61 5.30
Annual energy consumption kWh 410 593 793 593 793
Heating (Average Energy efficiency class A A+ A A+ A

CONTROL
SYSTEMS
climate) Pdesign kW 6.33 7.60
SCOP/A 3.90 4.01 3.85 4.01 3.85
Annual energy consumption kWh 2,273 2,654 2,764 2,654 2,764
Nominal efficiency EER 3.21 2.65 3.21 2.65
COP 3.61 3.41 3.61 3.41
Annual energy consumption kWh 1,060 1,480 2,265 1,480 2,265
Energy labeling Directive Cooling/Heating A/A D/B A/A D/B

Indoor unit FUA 71A 100A 125A 100A 125A

& ACCESSORIES
Dimensions Unit HeightxWidthxDepth mm 198x950x950

OPTIONS
Weight Unit kg 25.0 26.0
Air filter Type Resin net
Fan Air flow rate Cooling Low/Medium/High m³/min 16.0/19.5 /23.0 20.0/25.5 /31.0 20.5/26.5 /32.5 20.0/25.5 /31.0 20.5/26.5 /32.5
Heating Low/Medium/High m³/min 16.0/19.5 /23.0 20.0/25.5 /31.0 20.5/26.5 /32.5 20.0/25.5 /31.0 20.5/26.5 /32.5
Sound power level Cooling dBA 59 64 65 64 65
Heating dBA 59 64 65 64 65
Sound pressure level Cooling Low/High dBA 35/41 39/46 40/47 39/46 40/47
Heating Low/High dBA 35/41 39/46 40/47 39/46 40/47
Control systems Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
& PLATFORMS

Power supply Phase/Frequency/Voltage Hz/V 1~/ 50/60 / 220-240/220


TOOLS

Outdoor unit RZQSG 71L3V1 100L9V1 125L9V1 100L8Y1 125L8Y1


Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 67 72 74 82
Sound power level Cooling dBA 65 70
Sound pressure level Cooling Nom./Silent operation dBA 49/47 53/- 54/- 53/- 54/-
Heating Nom. dBA 51 57 58 57 58
Operation range Cooling Ambient Min.~Max. °CDB -15.0~46 -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-410A/2,087.5
TECHNICAL
DRAWINGS

Charge kg/TCO2Eq 2.75/5.7 2.9/6.1


Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 15 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16
MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing. |
PREVIOUS

Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | Nominal
heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series

83
FVA-A+ RZQG-L9V1/L(8)Y1

Floor standing unit


For commercial spaces with high ceilings

Combination with seasonal smart ensures best in class quality,


highest efficiency and performance

ʯʯ Unified range for R-32 and R-410A


ʯʯ Ideal solution for commercial and busy environments
ʯʯ Decrease of temperature variation by automatic fan speed FVA-A
selection or freely selectable 3-step fan speed.
ʯʯ Improved comfort as a result of better airflow distribution from
the vertical out blow which allows manual adjustment of air outlet
blades at the top of the unit.
ʯʯ Selectable horizontal out blow to better suit the layout of the
room (via wired remote controller BRC1E52)
ʯʯ No optional adapter needed for DIII-connection, link your unit into
the wider building management system. RZQG-L9V1/L(8)Y1 BRC1H51W BRP069A81

71A + 100A + 125A + 140A + 71A + 100A + 125A + 140A +


Efficiency data FVA + RZQG
71L9V1 100L9V1 125L9V1 140L9V1 71L8Y1 100L8Y1 125L8Y1 140LY1
Cooling capacity Nom. kW 6.80 9.50 12.0 13.4 6.80 9.50 12.0 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5
Power input Cooling Nom. kW 2.02 2.49 3.74 4.17 2.02 2.49 3.74 4.17
Heating Nom. kW 2.06 2.61 3.65 4.30 2.06 2.61 3.65 4.30
Seasonal efficiency Cooling Energy efficiency class A++ A+ A++ A+
(according to Pdesign kW 6.80 9.50 12.00 6.80 9.50 12.00
EN14825) SEER 6.23 5.61 6.23 5.61
Annual energy consumption kWh 383 593 749 383 593 749
Heating (Average Energy efficiency class A+ A A+ A
climate) Pdesign kW 6.33 11.30 6.33 11.30
SCOP/A 4.05 4.20 3.87 4.05 4.20 3.87
Annual energy consumption kWh 2,189 3,767 4,088 2,189 3,767 4,088
Nominal efficiency EER 3.37 3.81 3.21 3.37 3.81 3.21
COP 3.64 4.14 3.70 3.61 3.64 4.14 3.70 3.61
Annual energy consumption kWh 1,010 1,245 1,870 2,085 1,010 1,245 1,870 2,085
Energy labeling Directive Cooling/Heating A/A A/A A/A A/A A/A A/A

Indoor unit FVA 71A 100A 125A 140A 71A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350 1,850x600x270 1,850x600x350
Weight Unit kg 39 47 39 47
Air filter Type Resin net with mold resistance
Fan - Air flow rate Cooling High/Low m³/min 18/14 28/22 28/24 30/26 18/14 28/22 28/24 30/26
Heating High/Low m³/min 18/14 28/22 28/24 30/26 18/14 28/22 28/24 30/26
Sound power level Cooling dBA 55 62 63 65 55 62 63 65
Heating dBA 55 62 63 65 55 62 63 65
Sound pressure level Cooling High/Low dBA 43/38 50/44 51/46 53/48 43/38 50/44 51/46 53/48
Heating High/Low dBA 43/38 50/44 51/46 53/48 43/38 50/44 51/46 53/48
Refrigerant Type R-32 / R-410A
Control systems Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

Outdoor unit RZQG 71L9V1 100L9V1 125L9V1 140L9V1 71L8Y1 100L8Y1 125L8Y1 140LY1
Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 69 95 80 101
Sound power level Cooling dBA 64 66 67 69 64 66 67 69
Sound pressure level Cooling Nom. dBA 48 50 51 52 48 50 51 52
Heating Nom. dBA 50 52 53 50 52 53
Operation range Cooling Ambient Min.~Max. °CDB -15~50
Heating Ambient Min.~Max. °CWB -20~15.5
Refrigerant Type/GWP R-410A/2,087.5
Charge kg/TCO2Eq 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50 75 50 75
length System Equivalent m 70 90 70 90
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 25 40 16 25

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

84
SKY AIR INTRO
FVA-A + RZQSG-L3/L9V1/L(8)Y1

Floor standing unit


For commercial spaces with high ceilings

INDOOR
UNITS
Combination with Seasonal Classic ensures good value for money
for all types of commercial applications

ʯʯ Unified range for R-32 and R-410A


ʯʯ Ideal solution for commercial and busy environments
ʯʯ Decrease of temperature variation by automatic fan speed FVA-A
selection or freely selectable 3-step fan speed.
ʯʯ Improved comfort as a result of better airflow distribution from

OUTDOOR
UNITS
the vertical out blow which allows manual adjustment of air outlet
blades at the top of the unit.
ʯʯ Selectable horizontal out blow to better suit the layout of the
room (via wired remote controller BRC1E52)
ʯʯ No optional adapter needed for DIII-connection, link your unit into
the wider building management system. RZQSG-L3/9V1/L(8)Y1 BRC1H51W BRP069A81

AIR CURTAINS
BIDDLE
100A + 125A + 140A + 100A +
Efficiency data FVA + RZQSG 71A + 71L3V1 125A + 25L8Y1 140A + 140LY1
100L9V1 125L9V1 140L9V1 100L8Y1

VENTILATION
Cooling capacity Nom. kW 6.80 9.50 12.0 13.4 9.50 12.0 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Power input Cooling Nom. kW 2.12 2.96 4.27 4.45 2.96 4.27 4.45
Heating Nom. kW 2.08 2.99 3.96 4.54 2.99 3.96 4.54
Seasonal efficiency Cooling Energy efficiency class A A
(according to Pdesign kW 6.80 9.50 12.0 9.50 12.0
EN14825) SEER 5.50 5.50
Annual energy consumption kWh 433 605 764 605 764
Heating (Average Energy efficiency class A A+ A A+ A
climate) Pdesign kW 6.33 7.60 7.60
SCOP/A 3.86 4.01 3.85 4.01 3.85

CONTROL
SYSTEMS
Annual energy consumption kWh 2,297 2,654 2,764 4.02 3.86
Nominal efficiency EER 3.21 3.21 2.81 3.01 3.21 2.81 3.01
COP 3.61 3.61 3.41 3.41 3.61 3.41 3.41
Annual energy consumption kWh 1,060 1,480 2,135 2,225 1,480 2,135 2,225
Energy labeling Directive Cooling/Heating A/A A/B A/A C/B

Indoor unit FVA 71A 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350

& ACCESSORIES
Weight Unit kg 39 47

OPTIONS
Air filter Type Resin net with mold resistance
Fan - Air flow rate Cooling High/Low m³/min 18/14 28/22 28/24 30/26 28/22 28/24 30/26
Heating High/Low m³/min 18/14 28/22 28/24 30/26 28/22 28/24 30/26
Sound power level Cooling dBA 55 62 63 65 62 63 65
Heating dBA 55 62 63 65 62 63 65
Sound pressure level Cooling High/Low dBA 43/38 50/44 51/46 53/48 50/44 51/46 53/48
Heating High/Low dBA 43/38 50/44 51/46 53/48 50/44 51/46 53/48
Refrigerant Type R-32 / R-410A
Control systems Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
& PLATFORMS

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220


TOOLS

Outdoor unit RZQSG 71L3V1 100L9V1 125L9V1 140L9V1 100L8Y1 125L8Y1 140LY1
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 67 72 74 95 82 101
Sound power level Cooling dBA 65 70 69 70 69
Sound pressure level Cooling Nom./Silent operation dBA 49/47 53/- 54/- 53/- 54/- 53/-
Heating Nom. dBA 51 57 58 54 57 58 54
Operation range Cooling Ambient Min.~Max. °CDB -15.0~46 -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-410A/2,087.5
TECHNICAL
DRAWINGS

Charge kg/TCO2Eq 2.75/5.7 2.9/6.1 4.0/8.4 2.9/6.1 4.0/8.4


Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 15 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3N~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 - 16 20
PREVIOUS

(1) EER/COP according to Eurovent 2012, for use outside EU only


(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

85
86
SKY AIR INTRO
FNA-A + RXS-L(3) Split

Concealed floor standing unit


Designed to be concealed in walls

INDOOR
UNITS
Combination with split outdoor units is ideal for small retail, offices
or ­residential applications

ʯʯ Unified range for R-32 and R-410A


ʯʯ Ideal for installation in offices, hotels and residential applications
ʯʯ Blends unobtrusively with any interior design: only the suction FNQ-A
and discharge grills are visible
ʯʯ Its low height (620 mm) enables the unit to fit perfectly beneath a

OUTDOOR
UNITS
window
ʯʯ Requires very little installation space as the depth is only 200mm
ʯʯ High ESP allows flexible installation

RXS35L3 BRC1H51W BRP069A81

AIR CURTAINS
BIDDLE
Efficiency data FNA + RXS 25A + 25L3 35A + 35L3 50A + 50L 60A + 60L
Cooling capacity Nom. kW 2.60 3.40 5.00 6.00
Heating capacity Nom. kW 3.20 4.00 5.80 7.00
Power input Cooling Nom. kW 0.69 1.11 1.49 2.24

VENTILATION
Heating Nom. kW 0.80 1.15 1.74 2.25
Seasonal efficiency Cooling Energy efficiency class A+ A
(according to Pdesign kW 2.60 3.40 5.00 6.00
EN14825) SEER 5.63 5.65 5.72 5.51
Annual energy consumption kWh 162 211 306 381
Heating (Average Energy efficiency class A+
climate) Pdesign kW 2.80 2.90 4.00 4.60
SCOP/A 4.24 4.05 4.09 4.16
Annual energy consumption kWh 925 1,002 1,369 1,548
Nominal efficiency EER 3.77 3.06 3.35 2.68

CONTROL
SYSTEMS
COP 4.00 3.48 3.34 3.11
Annual energy consumption kWh 345 556 746 1,119
Energy labeling Directive Cooling/Heating A/A B/B A/C D/D

Indoor unit FNA 25A 35A 50A 60A


Dimensions Unit HeightxWidthxDepth mm 620 / 720(2)x750x200 620 / 720(2)x1,150x200
Weight Unit kg 23 30
Air filter Type Resin net with mold resistance
Fan - Air flow rate Cooling High/Low m³/min 8.7/7.3 16.0/13.5

& ACCESSORIES
Heating High/Low m³/min 8.7/7.3 16.0/13.5

OPTIONS
Fan - External static pressure High/Nom./Maximum available/High Pa 48/30/- 49/40/-
Sound power level Cooling dBA 53 56
Sound pressure level Cooling High/Low dBA 33/28 36/30
Heating High/Low dBA 33/28 36/30
Refrigerant Type R-32 / R-410A
Control systems Infrared remote control BRC4C65
Wired remote control BRC1H51 / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

Outdoor unit RXS 25L3 35L3 50L 60L


& PLATFORMS

Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300


TOOLS

Weight Unit kg 34 47 48
Sound power level Cooling dBA 59 61 62
Heating dBA 59 61 62
Sound pressure level Cooling Low/High dBA -/46 -/48 44/48 46/49
Heating Low/High dBA -/47 -/48 45/48 46/49
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-410A
GWP 2,087.5
Charge kg/TCO2Eq 1.0/2.1 1.2/2.5 1.7/3.5 1.5/3.1
TECHNICAL
DRAWINGS

Piping connections Liquid OD mm 6.35


Gas OD mm 9.5 12.7
Piping OU - IU Max. m 20 30
length System Chargeless m 10 -
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.020 (for piping length exceeding 10m)
Level difference IU - OU Max. m 15 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 1~/50/220-230-240
Current - 50Hz Maximum fuse amps (MFA) A -

(1) EER/COP according to Eurovent 2012, for use outside EU only


PREVIOUS

(2) Including installation legs (3) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer
to the electrical data drawing.

87
SKY AIR ALPHA-SERIES

SKY AIR ADVANCE-SERIES

SUPER INVERTER

88
SKY AIR INTRO
Outdoor
units

INDOOR
UNITS
OUTDOOR
UNITS
A range of industry
leading technology
outdoor units

AIR CURTAINS
Products overview  90

BIDDLE
Benefits overview 91

Sky Air pair, twin, triple, Pair solution


double twin applications 92

VENTILATION
range 102
RZAG-MV1/MY1 102

RZASG-MV1/MY1 103

AZAS-MV1/MY1 104

CONTROL
SYSTEMS
range 105
Twin, triple, double twin solution
RZQG-L9V1/L(8)Y1 Seasonal Smart 105

& ACCESSORIES
RZQSG-L3/L9V1/LY1 106

OPTIONS
AZQS-B8V1/BY1 107

RZQ-C 108 & PLATFORMS


TOOLS

Multi model and VRV range 109


›› Connect up to 5 different Sky Air units
to our multi range
Multi solution
›› Connect up to 9 different Sky Air units
to our Sky Air VRV range
›› For more info split en VRV installer catalogue
TECHNICAL
DRAWINGS
PREVIOUS

89
Outdoor units

Products overview outdoor units

Pair, twin, triple & double twin application


Capacity clas
System Type Model Product name PG 71 100 125 140
6.8 kW 9.5 kW 12.1 kW 13.4 kW

RZAG-MV1 102

- Industry leading technology for commercial applications


--Dedicated solution for infrastructure cooling
--Variable Refrigerant Temperature
--Maximum piping length up to 85m
--Replacement technology RZAG-MY1 102
--Extended operation range down to -20°C in both heating and cooling
--Pair, twin, triple and double twin application

RZASG-MV1 103
Air Heat
cooled pump --Technology and comfort combined for commercial applications
--Very compact and easy to install outdoor units
--Maximum piping length up to 50m
--Replacement technology RZASG-MY1 103
--Operation range down to -15°C both cooling and in heating
--Pair, twin, triple and double twin application

AZAS-MV1 104

--Ideal solution for busy environments and small shops


--Very compact and easy to install outdoor units
--Maximum piping length up to 30m
--Replacement technology AZAS-MY1 104
--Easy-to-mount outdoor units: roof, terrace or wall
--Exclusively offered for pair applications

Pair, twin, triple & double twin application


Capacity class
System Type Model Product name PG 71 100 125 140 200 250

--Industry leading technology for commercial applications


--Dedicated solution for infrastructure cooling
RZQG-L9V1 105
• • • •
--Variable Refrigerant Temperature
--Maximum piping length up to 75m
--Re-use technology
--Extended operation range down to -20°C in heating and
-15°C in cooling
RZQG-L(8)Y1 105
• • • •
--Pair, twin, triple and double twin application

• • • •
--Technology and comfort combined for commercial RZQSG-L3/
106
applications L9V1
--Maximum piping length up to 50m
--Re-use technology
Air Heat --Operation range down to -15°C
cooled pump both cooling and in heating
--Pair, twin, triple and double twin application
RZQSG-L(8)Y1 106
• • •
Standard outdoor unit
--Ideal solution for busy environments and small shops
AZQS-B8V1 107
• • • •
--Easy-to-mount outdoor units: roof, terrace or wall
--
• • •
--Outdoor units with swing or scroll compressor
AZQS-BY1 107
--Exclusively offered for pair applications

--Packaged system for commercial applications


--For large commercial applications
--Re-use technology
RZQ-C 108
• •
--Pair, twin, triple and double twin applications

90
SKY AIR INTRO
Outdoor units

Benefits overview outdoor units

RZQSG-L3/9V1/L(8)Y1
RZASG-MV1 / MY1
RZAG-MV1 / MY1

AZAS-MV1 / MY1

INDOOR
UNITS
B8V1/BY1
RZQG-L9V1/

AZQS-

RZQ-C
L(8)Y1-

OUTDOOR
Seasonal efficiency - Seasonal efficiency gives a more realistic indication on how efficient air

UNITS
We care icons

Smart use of energy conditioners operate over an entire heating or cooling season.

Inverter technology In combination with inverter controlled outdoor units       


Replacement
technology
Quick and quality system replacement in the most cost effective way       
Night quiet Lowers the operation sound of the outdoor unit automatically.     
Comfort

AIR CURTAINS
Auto cooling-heating Automatically selects cooling or heating mode to achieve the set
      

BIDDLE
changeover temperature.

Variable refrigeration The intelligent systems ensures highest energy savings with additional
temperature comfort to better suit application requirements.  
2, 3 or 4 indoor units can be connected to only 1 outdoor unit even if
Twin/triple/double
twin application
they have different capacities. All indoor units operate within the same
mode (cooling or heating) from one remote control.
    
Other functions

Up to 5 indoor units (even different capacities) can be connected to a

VENTILATION
Multi model application single outdoor unit. All indoor units can individually be operated within
the same mode.
Outdoor units are fitted with a swing compressor, renowned for its low
Swing compressor
noise and high reliability       
Guaranteed operation Daikin is suitable for all climates, even withstanding severe winter
down to -20°C conditions with an operation range down to -20°C.  
For high sensible, infrastructure cooling applications, dedicated
Infrastructure cooling infrastructure cooling settings and allowing asymmetric combinations
enhance the system’s reliability.
 

CONTROL
SYSTEMS
Technical benefit overview

& ACCESSORIES
OPTIONS
Compact single fan casing on the entire range  
Maximum piping length 85 m 50 m 30 m

Pivoting front plate   


& PLATFORMS

7 segment display   
TOOLS

Increased factory charge 


Integrated leak check 
Refrigerant bottom plate pass 
Specially deveoloped R-32 swing compressor   
Refrigerant cooled PCB   
Intelligent Tablet controller - Online controller app   
TECHNICAL
DRAWINGS
PREVIOUS

91
The new Sky Air A-series,
built for all Sky Air applications

Lighter and more compact units for


770 mm 990 mm
easy installation.
Unique single fan range up to 14 kW
Full range below 1m in height!

New replacement technology


A quicker, easier and more reliable approach when
replacing existing systems

›› Hepta filtration ensures reliable operation without the need for pipe
cleaning

Increased piping length up to 85m


Kan niet aders dan met
Kan niet aders dan met
gradient, want vloeistof
gradient, want vloeistof
warmt op en koelt af...
warmt op en koelt af...

Widest operation range -20C° DB 52°C DB -20C° WB 15.5°C WB

›› Cooling operation from -20°C to 52°C


›› Heating operation down to -20°C

Faster installation with up to


40m pre-charged pipe even checken in de even checken in de
infographics map: ikinfographics
denk map: ik denk
dat er een tekening dat
vaner een tekening van
een VRV bestaat een VRV bestaat
›› Up to 60% of applications can be installed
without additional refrigerant charge

Redesigned pivoting front plate


for easy access to vital system
components 1 v/d 2 kiezen 1 v/d 2 kiezen

92
SKY AIR INTRO
New 7-segment display to view
errors and systems settings

INDOOR
UNITS
Guaranteed reliable performance in bottom plate
refrigerant pass
all weather conditions
New refrigerant passes
Lower part of the outdoor heat exchanger and drain holes are kept

OUTDOOR
Temperature around El. Box

UNITS
completely open and free of ice allowing ice water to evacuate perfectly,
Others
eliminating all risk of ice build-up.

›› Refrigerant cooled PCB’s Daikin


Reliable and stable cooling, independent from outdoor conditions

AIR CURTAINS
BIDDLE
Integrated leak-check function 
Reliable refrigerant cooled PCB’s Time

reduces on-site checks and improves


reliability

VENTILATION
Daikin Sky Air A-series uses patented
Daikin technology at the heart of the system

CONTROL
SYSTEMS
3-row heat exchanger
›› Unqiue 3-row heat exchanger
Refrigerant cooled PCB

& ACCESSORIES
to allow compact casing up to

OPTIONS
14 kW
Daikin swing compressor

Jigsaw curved propeller


›› Curved discharge grill and Jigsaw Integration of main moving parts
curved propeller for minimal
& PLATFORMS

into one component


turbulence and optimal airflow
TOOLS

›› No abrasion or friction UNIQUE


›› No refrigerant leakages &
›› No temperature rise PATENTED
Bottom plate and because of leakage TECHNOLOGY
heat exchanger
refrigerant pass ›› High compressor efficiencies
›› Drain holes are kept ›› Increased system life span
TECHNICAL
DRAWINGS

ice free
›› Guaranteed operation
down to -20°C
PREVIOUS

93
Outdoor units

Replacement technology
The quick and quality way of upgrading R-22 and R-410A systems

Benefits to increase The benefits will convice your customer


your profit
To prevent unexpected breakdown
Optimise your business
To lower running costs
Less installation time
Tackle more projects in less time thanks to faster To protect the environment
installation. It is more profitable than replacing the
full system with new piping. To improve comfort

Lower installation costs


Reducing installation costs enables you to offer Your copper pipes will last for multiple generations
customers the most cost-effective solution and
improve your competitive edge. - copper pipes used in air conditioning systems tested by Daikin
will last over 60 years after installation.
Replace non-Daikin systems
- Japan/China have replaced with VRV Q-series
already 10 years ago!
It is a trouble-free replacement solution for
Daikin systems and for systems made by other Umeda Center Building, Japan
manufacturers. - original A/C system: 20 years in use
- replacement with VRV Q-series:
Easy as one-two-three 2006 - 2009
2013
A simple solution for replacement technology - capacity up from 1620HP to 2322HP (1st)
enables you to handle more projects for more - SHASE renewal award:
customers in less time and offer them the best price!
Everybody gains.

How does it work? Unique technologies


The Daikin low-cost upgrade solution ›› Cleaning free piping re-usage thanks to unique hepta filtering for maximum
particle reduction
! Replace indoor units
Contact your local dealer to check compatibility in 1 2 3 4 1 2 3 4
case you need to keep the indoor units.

›› LPS
HPS-A

✓ Replace outdoor units 5

Learn more about Daikin replacement solutions at ›› New expansion valve needle material,
www.daikin.eu/en_us/knowledge-center/
with high corrosion resistance
replacement-technology.html
›› New type oil for maximum system protection
94
SKY AIR INTRO
Outdoor units

New simplified replacement


procedure with Sky Air
A-series outdoor units

INDOOR
UNITS
How does it work?

1 Evaluate if the pipe work can be re-used

OUTDOOR
UNITS
Check if the piping installation is according to standards, that there no fractures or damages
and that liquid and gas pipe have separate insulation

Verify pipe thickness


Outside diameter (mm) Material Thickness (mm)

AIR CURTAINS
6.4 o 0.8
9.5 o 0.8

BIDDLE
12.7 o 0.8
15.9 o 1.0
19.1 1/2H 1.0
o: annealed - 1/2H: half hard

Verify piping diameter


 Possible (Standard condition)
Liquid 6.4 9.5 12.7
Gas 9.5 12.7 15.9 19.1 15.9 19.1 o Possible (With no impact on chargeless length

VENTILATION
Sky Air 7.1kW x ∆ ∆  x ∆ x
and total length)
10.0-14.0kW x x ∆  o ∆ ∆
20.0-25.0kW Refrigerant pipe size-up required. Please consult the RZQ-C installation manual. ∆ Possible (With impact on chargeless length
and total length )
Verify the piping length x Impossible

RZAG Liquid pipe (mm) 71 100 125-140


6.4 10 / (15) m
Chargeless (equivalent) 9.5 40 / (50) m
12.7 15 / (20) m

CONTROL
SYSTEMS
6.4 10 / (15) m
Max. total length (equivalent) 9.5 55 / (75) m 85 / (100) m
12.7 25 / (35) m 35 / (45) m

Check if any operation history affects the ability to re-use the pipes(systems with a pipe length
up to 35m, can always re-use exisiting pipe work when using a new Sky Air A-series model)
System to be replaced System condition Piping length

& ACCESSORIES
R-32 Sky Air A-series

OPTIONS
(RZAG/RZASG/AZAS)
Unit is operating
R-22 No restrictions 
(pump down can be performed)
(mineral oil) Below 35 m 
Pump down operation impossibility or
compressor malfunction
Above 35 m o
Unit is operating No restrictions 
R-410A (pump down can be performed)
(synthetic oil) Below 35 m 
& PLATFORMS

Pump down operation impossibility or


compressor malfunction
Above 35 m o
TOOLS

Unit is operating No restrictions 


R-32 (pump down can be performed)
(synthetic oil) Below 35 m 
Pump down operation impossibility or
compressor malfunction
Above 35 m o

 Cleaning-free piping re-use


o Cleaning of field piping or replacement of field piping is required
TECHNICAL
DRAWINGS

The Flare connection MUST be redone by using the flare nut included with the new outdoor unit

2 Evaluate if the wiring can be re-used


Check if the wiring meets current standard and the specificaton of the new unit
and that there is no damage or scratches
PREVIOUS

note: For general installation guidelines and requirements please check the installation manual of the specific outdoor model

95
Outdoor units

Variable Refrigerant
Temperature

The ultimate customer experience


Increases air discharge temperature Weather dependent limitation
and eliminates cold drafts! ›› Two defined outdoor temperatures trigger the changeover of the Te
›› Between those two trigger values the Te will change linear
Increased customer comfort and
reduced energy consumption!

›› The system automatically increases its evaporating Min. Te1 Depending on the gap between
indoor t° and set point the Te
temperature (Te) when the gap between the actual will be increased or decreased
indoor temperature (Tin) and the setpoint (Tset) is Lin
ear
Te
becoming smaller li mit
›› Possibility to customize the evaporating limits Min. Te2

20° 31° Ta
Outdoor t° trigger values
Quick cooling
(selected on remote control)

Case study: Clothing shop in the Brussels area


Outdoor Indoor Deco panel Control
Two pair systems are installed in the
System 1 = VRT enabled (Alpha 1) RZAG125MV1 FCAG125A BYCQ140D
same zone allowing comparison 1 x BRC1E53A
System 2 = Factory settings (Alpha 2) RZAG125MV1 FCAG125A BYCQ140D

More energy efficient:


up to 20% lower energy consumption
VRT enabled

Average energy consumption over 5 months No VRT

of operation

Apr May Jun Jul Aug

Td   30.0  
Improved comfort: 25.0  

higher discharge temperatures 20.0  


Alpha  01  
[VRT  enabled]  
15.0  
›› More stable and continuous operation Alpha  02  
[Default  set]  
10.0  
›› Average discharge temperature increased with 3~4°C
5.0  

0.0   t  

96
SKY AIR INTRO
Infrastructure cooling solution

INDOOR
UNITS
Infrastructure
cooling

OUTDOOR
UNITS
Daikin is the world leader when it comes to cooling. With over 90 years of
innovation and engineering expertise in specialised cooling, Daikin offers a Sky
Air solution that is reliable, efficient and flexible to meet the demanding needs
of infrastructure cooling environments.

AIR CURTAINS
BIDDLE
Reliable Efficient Flexible
Guaranteed system operation: Optimum return on investment:
›› Oversized indoor units boost cooling ›› Lowers running costs by using highly effi- ›› Scalable in capacity
capacity and prevent freeze-ups on the cient direct expansion cooling systems ›› Improved infrastructure control and
indoor side ›› Lower running costs compared to other management

VENTILATION
›› Wide operating range envelope: opera- DX systems and water based chillers. ›› Lower physical footprint since no floor
tion range in cooling down to -20°C and ›› Minimises environmental impact with space is occupied
up to +52°C A++ energy labels ›› Wide range of indoor units to suit appli-
›› Reduces mechanical cooling and energy cation preferences (ceiling suspended
consumption with the free cooling op- cassettes, wall mounted indoors, con-
tion for single phase systems cealed ceiling ducted type indoors)

CONTROL
SYSTEMS
UNIQUE UNIQUE

Dedicated system 2-step solution


combinations for system selection
Benefits Benefits

& ACCESSORIES
1. Boost the heat transfer capacity of the 1. Daikin makes the system selection

OPTIONS
indoor system procedure easy and reliable by provid-
2. Ability to work with higher evaporation ing detailed capacity tables based on
temperatures (Te) avoids downtime and extensive testing.
enables continuous operation 2. Choose the best product combination
3. Official energy labels for indoor and that meets end-user requirements
outdoor system combinations provide
standardized and reliable performance
& PLATFORMS

data
TOOLS

UNIQUE UNIQUE

Efficient cooling Flexible control ON


TINUOUS O
C

PE
RELIABLE,

RATION

Infrastructure
Benefits Benefits cooling solution
TECHNICAL
DRAWINGS

1. Free cooling: optimum energy efficiency 1. Optimal backup supported by duty


using cold ambient air rotation control, automatic backup
2. Widest range of indoor systems with best activation and remote alarms
in class energy efficiency 2. Guaranteed continuous operation from
3. Wide indoor and outdoor operation extended compressor limits
range, reliable performance even in 3. Controller settings to adapt to specific
extreme conditions infrastructure cooling environment › For server rooms, telecom shelters, laboratories, IT applications

conditions
PREVIOUS

4. Fewer start/stop cycles Find out more in our infrastructure


cooling brochure

97
Infrastructure cooling solution

Boosted capacity indoor systems


High reliability at lower running costs for infrastructure cooling
Split air conditioning systems for normal comfort environments need enhanced capabilities for
cooling applications usually combine indoor systems continuous heat transfer because they work
with matching capacities, or multiple indoor systems harder to extract energy by cooling dry air.
with capacities lower than the outdoor system’s Daikin recommends and offers asymmetric
capacity. This works because the indoor system’s combinations (boosted capacity indoor
cooling capacity is sufficient to handle the higher combinations: e.g. 71 class outdoor + 100 class indoor).
humidity conditions and varying indoor temperature
requirements that are common in a normal living
environment.
Applying this design logic to infrastructure You can now confidently combine indoor
cooling environments can lead to risky situations systems with higher capacities than the outdoor
that might compromise overall system reliability system. This will boost heat transfer inside the
and frequent downtimes of 15 minutes. technology or server room environments.
Indoor systems for infrastructure cooling

Infrastructure cooling application system solutions


traditional solution dedicated solution

Symmetric indoor-outdoor system combination


Te kW RH% Te kW RH%
12 12 55 12 12 55
Between
50 50 20-40%
10 10 10 10 sensible capacity
45 45 increase
8 8 40 8 8 40
Evaporating Temperature

Evaporating Temperature

35 35
6 6 6 6
30 30

4 4 25 4 4 25
Capacity

Capacity

Time Time
Relative Humidity: reduces over time Improved solution
Capacity: reduced Boosted capacity indoors increase the heat transfer capacity at
Evaporating temp: drops to compensate reduced capacity low relative humidity
too low Te can lead to freeze-up Allows the system to operate with higher Te, guaranteeing
prevention, causing system downtime continuous operation and reducing unwanted dehumidification

Low humidity + Low ambient environment 18%


savings on
Outside temperature Ta -5 °C running cost
Set-point 22 °C EER
Humidity 35 % traditional solution 100%
Indoor wet-bulb temperature 13 °C improved solution 82% 18% SAVINGS

traditional solution dedicated system combination solution


71 class outdoor with 71 class indoor 71 class outdoor with 100 class indoor
Total Capacity (TC) 5.63 kW Total Capacity (TC) 6,02 kW Sensible Heat Capacity
Sensible Heat Capacity (SHC) 4.28 kW Sensible Heat Capacity (SHC) 6,02 kW increases 20-40%
Power Input (PI) 2 kW Power Input (PI) 2 kW with dedicated system
Co-efficient of Power Input (CPI) 0.39 Co-efficient of Power Input (CPI) 0,45 combination.
Corrected PI 0.78 kW Corrected PI 0.90 kW
EER* 5,5 EER* 6,7 *EER = (SHC/Corrected PI)

98
SKY AIR INTRO
Infrastructure cooling solution

2-Step solution for system selection

INDOOR
UNITS
High reliability for infrastructure cooling
UNIQUE

Select your infrastructure cooling system in 2 steps

OUTDOOR
UNITS
No humidity generation in room Some humidity source in room
(eg: Server room) STEP 1 (eg: Laboratory)
IT room requires 22°C inside. It will have 7kW of sensible Determine Lab requires 22°C inside. It will have 9 kW of sensible
cooling demand, and no latent cooling demand (no requested indoor cooling demand, and some humidity generation in
humidity generation) throughout the year. conditions the room (est. indoor humidity level 42%).
Ceiling suspended indoor unit is the customer's and required Wall mounted indoor unit is the customer’s

AIR CURTAINS
preference for the server room. cooling demand preference for the laboratory.

BIDDLE
Indoor temperature = 22°CDB (Sensible and Indoor temperature = 22°CDB
Sensible cooling demand (SHC) = 7 kW Total capacity) Indoor Relative Humidity (RH%) = 42%**
Latent cooling demand (LC) = 0 kW* Sensible cooling demand (SHC) = 9 kW
Total cooling demand (TC) = SHC + LC = 7 kW Latent cooling demand (LC) = 0.9 kW
Outdoor temperature operating range = -15°C ~ +40°C Total cooling demand (TC) = SHC + LC = 9.9 kW
Most stringent outdoor unit capacity condition = -15°C Outdoor temperature operating range = -10°C ~ +40°C
Most stringent outdoor unit capacity condition = -10°C

VENTILATION
solution STEP 2 solution
Boosted capacity indoor combination Select the system Boosted capacity indoor combination
with 10kW outdoor system. combination from with 12.5kW outdoor system.
the given table,
100 class outdoor + 140 class indoor where the system ‘s 125 class outdoor with twin 71 class indoor
Total capacity = 7.48 kW sensible and total Total capacity = 10.45 kW

CONTROL
SYSTEMS
Sensible capacity = 7.48 kW capacity meets the Sensible capacity = 9.34 kW
Power input = 0.42 x 2.49 = 1.04 kW cooling demand Power input = 0.48 x 3.69 = 1.78 kW
at the requested
indoor and outdoor
* If there is no latent cooling demand, look for conditions where
TC = SHC, since no more dehumidification will occur and thus the temperatures.
indoor environment will stabilize. When TC > SHC and there is no ** System capacity at 42%RH (14,2°CWB) can be found by interpola-
humidity generation, the indoor humidity will gradually decrease. tion between 13°CWB (35%) and 15°CWB (48%).

& ACCESSORIES
OPTIONS

Combination table for boosted capacity indoor systems


& PLATFORMS
TOOLS

Sky Air Wall Ceiling suspended unit Concealed ceiling unit Concealed 4-way blow Floor standing Fully flat High COP, Round flow cassette
mounted with medium ESP ceiling ceiling unit cassette round flow
unit mounted cassette
cassette
FCAHG100

FCAHG140
FCAHG125
FCAHG71

FCAG100

FCAG140
FCAG125
FDXM60
FDXM50
FDXM35

FCAG60
FCAG50
FCAG35

FCAG71
FHA100

FHA140

FUA100
FAA100

FVA100
FHA125

FVA140

Model
FBA100

FBA140

FUA125

FVA125
FBA125
FHA60
FHA50
FHA35

FBA60
FBA50
FBA35

FFA60
FFA50
FHA71

FUA71
FAA71

FFA35
FVA71
FBA71

TECHNICAL
DRAWINGS

RZAG71 / RZQG71 P 3 2 P 3 2 P 3 2 P P 3 2 P 3 2 P
RZAG100 / RZQG100 2 4 3 2 P 4 3 2 P 4 3 2 2 P 4 3 2 P 4 3 2 P
RZAG125 / RZQG125 2 4 3 2 P 4 3 2 P 4 3 2 2 P 4 3 2 P 4 3 2 P
RZAG140 / RZQG140 2 4 3 2 P 4 3 2 P 4 3 2 2 P 4 3 2 P 4 3 2 P

Possible combinations: P = Pair 2 = Twin 3 = Triple 4 = Double Twin


Notes: The capacities in the table are combined capacities (multiple units operating simultaneously) and not individual indoor unit capacities. When combining multiple indoor
PREVIOUS

units, designate the master unit as the unit whose remote controller is equipped with the most functions. Refer to the option list when selecting the correct refnet kit required to
install a multi-combination.

99
Infrastructure cooling solution

Performance characteristics
for boosted capacity indoor combinations

Boosted capacity indoors with 7kW outdoor system


RZAG71MV1/MY1

Outdoor temperature [°C DB]


Indoor -15 -10 -5 0 5 10 15 20 25 30 35 40
TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI
RH [%] °CWB °CDB kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW -
54.5 11 16 4.81 3.98 0.34 4.81 3.98 0.36 4.81 3.98 0.37 4.81 3.98 0.39 4.81 3.98 0.41 4.81 3.98 0.43 4.81 3.98 0.46 4.81 3.98 0.48 5.90 5.25 0.98 5.85 5.22 1.09 5.80 5.20 1.19 5.76 5.17 1.30
41.8 11 4.81 4.67 0.34 4.81 4.67 0.36 4.81 4.67 0.37 4.81 4.67 0.39 4.81 4.67 0.41 4.81 4.67 0.43 4.81 4.67 0.46 4.81 4.67 0.48 5.90 5.90 0.98 5.85 5.85 1.09 5.80 5.80 1.19 5.76 5.76 1.30
18
57 13 6.02 5.05 0.37 6.02 5.05 0.41 6.02 5.05 0.45 6.02 5.05 0.50 6.02 5.05 0.52 6.02 5.05 0.55 6.02 5.05 0.57 6.02 5.05 0.64 7.49 5.89 0.99 7.23 5.75 1.10 6.96 5.61 1.20 6.70 5.47 1.31
31.4 11 4.81 4.81 0.34 4.81 4.81 0.36 4.81 4.81 0.37 4.81 4.81 0.39 4.81 4.81 0.41 4.81 4.81 0.43 4.81 4.81 0.46 4.81 4.81 0.48 5.90 5.90 0.98 5.85 5.85 1.09 5.80 5.80 1.19 5.76 5.76 1.30
44.9 13 20 6.02 6.02 0.37 6.02 6.02 0.41 6.02 6.02 0.45 6.02 6.02 0.50 6.02 6.02 0.52 6.02 6.02 0.55 6.02 6.02 0.57 6.02 6.02 0.64 7.49 7.00 0.99 7.23 6.81 1.10 6.96 6.60 1.20 6.70 6.37 1.31
52 14 6.62 5.76 0.38 6.62 5.76 0.44 6.62 5.76 0.50 6.62 5.76 0.55 6.62 5.76 0.58 6.62 5.76 0.60 6.62 5.76 0.63 6.62 5.76 0.72 8.15 6.56 0.99 7.74 6.36 1.10 7.34 6.15 1.20 6.93 5.93 1.31
22.9 11 4.81 4.81 0.34 4.81 4.81 0.36 4.81 4.81 0.37 4.81 4.81 0.39 4.81 4.81 0.41 4.81 4.81 0.43 4.81 4.81 0.46 4.81 4.81 0.48 5.90 5.90 0.98 5.85 5.85 1.09 5.80 5.80 1.19 5.76 5.76 1.30
34.8 13 6.02 6.02 0.37 6.02 6.02 0.41 6.02 6.02 0.45 6.02 6.02 0.50 6.02 6.02 0.52 6.02 6.02 0.55 6.02 6.02 0.57 6.02 6.02 0.64 7.49 7.49 0.99 7.23 7.23 1.10 6.96 6.96 1.20 6.70 6.70 1.31
22
47.6 15 7.22 6.06 0.39 7.22 6.06 0.46 7.22 6.06 0.54 7.22 6.06 0.61 7.22 6.06 0.63 7.22 6.06 0.66 7.22 6.06 0.69 7.22 6.06 0.79 8.41 7.00 1.00 7.99 6.80 1.11 7.58 6.60 1.21 7.16 6.37 1.32
54.3 16 7.82 5.71 0.41 7.82 5.71 0.49 7.82 5.71 0.58 7.82 5.71 0.66 7.82 5.71 0.69 7.82 5.71 0.72 7.82 5.71 0.75 7.82 5.71 0.87 8.68 6.54 1.00 8.25 6.35 1.11 7.83 6.14 1.21 7.40 5.92 1.32
21.2 12 5.41 5.41 0.36 5.41 5.41 0.38 5.41 5.41 0.41 5.41 5.41 0.44 5.41 5.41 0.46 5.41 5.41 0.49 5.41 5.41 0.52 5.41 5.41 0.56 6.70 6.70 0.99 6.54 6.54 1.10 6.38 6.38 1.20 6.23 6.23 1.31
32.1 14 6.62 6.62 0.38 6.62 6.62 0.44 6.62 6.62 0.50 6.62 6.62 0.55 6.62 6.62 0.58 6.62 6.62 0.60 6.62 6.62 0.63 6.62 6.62 0.72 8.15 8.15 0.99 7.74 7.74 1.10 7.34 7.34 1.20 6.93 6.93 1.31
24
43.8 16 7.82 6.57 0.41 7.82 6.57 0.49 7.82 6.57 0.58 7.82 6.57 0.66 7.82 6.57 0.69 7.82 6.57 0.72 7.82 6.57 0.75 7.82 6.57 0.87 8.68 7.45 1.00 8.25 7.26 1.11 7.83 7.04 1.21 7.40 6.82 1.32
50 17 8.10 6.08 0.43 8.10 6.08 0.51 8.10 6.08 0.60 8.10 6.08 0.68 8.10 6.08 0.70 8.10 6.08 0.73 8.10 6.08 0.75 8.10 6.08 0.88 8.96 6.99 1.00 8.53 6.80 1.11 8.09 6.59 1.21 7.66 6.37 1.32
21.5 14 6.62 6.62 0.38 6.62 6.62 0.44 6.62 6.62 0.50 6.62 6.62 0.55 6.62 6.62 0.58 6.62 6.62 0.60 6.62 6.62 0.63 6.62 6.62 0.72 8.15 8.15 0.99 7.74 7.74 1.10 7.34 7.34 1.20 6.93 6.93 1.31
26.3 15 27 7.22 7.22 0.39 7.22 7.22 0.46 7.22 7.22 0.54 7.22 7.22 0.61 7.22 7.22 0.63 7.22 7.22 0.66 7.22 7.22 0.69 7.22 7.22 0.79 8.41 8.41 1.00 7.99 7.99 1.11 7.58 7.58 1.21 7.16 7.16 1.32
31.3 16 7.82 0.41 7.82 7.82 0.49 7.82 7.82 0.58 7.82 7.82 0.66 7.82 7.82 0.69 7.82 7.82 0.72 7.82 7.82 0.75 7.82 7.82 0.87 8.68 8.68 1.00 8.25 8.25 1.11 7.83 7.83 1.21 7.40 7.40 1.32
3D098206A

PAIR FAA100 FHA100 FBA100 FUA100 FVA100 FCAHG100 FCAG100 TWIN FHA50 x 2 FBA50 x 2 FDXM50 x 2 FFA50 x 2 FCAG50 x 2
Cooling 2.00 1.78 1.89 1.67 2.02 1.66 2.01 Cooling 2.34 2.02 2.23 2.02 2.04

TRIPLE FHA35 x 3 FBA35 x 3 FDXM35 x 3 FFA35 x 3 FCAG35 x 3


Cooling 2.39 2.11 2.26 2.07 2.06

Note : blue cells contain preliminary data


Boosted capacity indoors with 10kW outdoor system
RZAG100MV1/MY1
Outdoor temperature [°C DB]
Indoor -15 -10 -5 0 5 10 15 20 25 30 35 40
TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI
RH [%] °CWB °CDB kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW -
54.5 11 16 6.00 5.63 0.33 6.00 5.63 0.34 6.00 5.63 0.35 6.00 5.63 0.37 6.00 5.63 0.38 6.00 5.63 0.38 6.00 5.63 0.39 6.00 5.63 0.39 8.36 7.11 1.00 7.92 6.83 1.10 7.48 6.53 1.20 7.09 6.28 1.29
41.8 11 6.00 6.00 0.33 6.00 6.00 0.34 6.00 6.00 0.35 6.00 6.00 0.37 6.00 6.00 0.38 6.00 6.00 0.38 6.00 6.00 0.39 6.00 6.00 0.39 8.36 7.98 1.00 7.92 7.72 1.10 7.48 7.43 1.20 7.09 7.15 1.29
18
57 13 7.48 6.37 0.42 7.48 6.37 0.44 7.48 6.37 0.45 7.48 6.37 0.46 7.48 6.37 0.46 7.48 6.37 0.46 7.48 6.37 0.45 7.48 6.37 0.46 9.71 7.67 1.00 9.30 7.42 1.11 8.90 7.16 1.21 8.45 6.88 1.30
31.4 11 6.00 6.00 0.33 6.00 6.00 0.34 6.00 6.00 0.35 6.00 6.00 0.37 6.00 6.00 0.38 6.00 6.00 0.38 6.00 6.00 0.39 6.00 6.00 0.39 8.36 8.36 1.00 7.92 7.92 1.10 7.48 7.48 1.20 7.09 7.09 1.29
44.9 13 20 7.48 7.25 0.42 7.48 7.25 0.44 7.48 7.25 0.45 7.48 7.25 0.46 7.48 7.25 0.46 7.48 7.25 0.46 7.48 7.25 0.45 7.48 7.25 0.46 9.71 8.53 1.00 9.30 8.28 1.11 8.90 8.01 1.21 8.45 7.74 1.30
52 14 8.22 7.18 0.47 8.22 7.18 0.48 8.22 7.18 0.49 8.22 7.18 0.51 8.22 7.18 0.50 8.22 7.18 0.49 8.22 7.18 0.49 8.22 7.18 0.49 10.50 8.45 1.01 10.23 8.31 1.11 9.96 8.17 1.21 9.68 7.94 1.31
22.9 11 6.00 6.00 0.33 6.00 6.00 0.34 6.00 6.00 0.35 6.00 6.00 0.37 6.00 6.00 0.38 6.00 6.00 0.38 6.00 6.00 0.39 6.00 6.00 0.39 8.36 8.36 1.00 7.92 7.92 1.10 7.48 7.48 1.20 7.09 7.09 1.29
34.8 13 7.48 7.48 0.42 7.48 7.48 0.44 7.48 7.48 0.45 7.48 7.48 0.46 7.48 7.48 0.46 7.48 7.48 0.46 7.48 7.48 0.45 7.48 7.48 0.46 9.71 9.71 1.00 9.30 9.30 1.11 8.90 8.90 1.21 8.45 8.45 1.30
22
47.6 15 8.96 7.82 0.52 8.96 7.82 0.53 8.96 7.82 0.54 8.96 7.82 0.55 8.96 7.82 0.54 8.96 7.82 0.53 8.96 7.82 0.52 8.96 7.82 0.52 11.28 9.19 1.01 10.89 8.96 1.11 10.51 8.72 1.22 10.12 8.48 1.32
54.3 16 9.70 7.54 0.56 9.70 7.54 0.58 9.70 7.54 0.59 9.70 7.54 0.60 9.70 7.54 0.59 9.70 7.54 0.57 9.70 7.54 0.55 9.70 7.54 0.56 11.84 8.40 1.01 11.40 8.22 1.11 11.03 8.04 1.22 10.58 7.77 1.32
21.2 12 6.74 6.74 0.38 6.74 6.74 0.39 6.74 6.74 0.40 6.74 6.74 0.41 6.74 6.74 0.42 6.74 6.74 0.42 6.74 6.74 0.42 6.74 6.74 0.42 9.04 9.04 1.00 8.61 8.61 1.10 8.19 8.19 1.21 7.77 7.77 1.30
32.1 14 8.22 8.22 0.47 8.22 8.22 0.48 8.22 8.22 0.49 8.22 8.22 0.51 8.22 8.22 0.50 8.22 8.22 0.49 8.22 8.22 0.49 8.22 8.22 0.49 10.50 10.50 1.01 10.23 10.23 1.11 9.96 9.96 1.21 9.68 9.68 1.31
24
43.8 16 9.70 8.68 0.56 9.70 8.68 0.58 9.70 8.68 0.59 9.70 8.68 0.60 9.70 8.68 0.59 9.70 8.68 0.57 9.70 8.68 0.55 9.70 8.68 0.56 11.84 9.74 1.01 11.40 9.51 1.12 11.03 9.32 1.22 10.58 9.06 1.32
50 17 9.98 7.86 0.58 9.98 7.86 0.59 9.98 7.86 0.60 9.98 7.86 0.61 9.98 7.86 0.60 9.98 7.86 0.60 9.98 7.86 0.60 9.98 7.86 0.60 12.39 9.45 1.02 11.86 9.16 1.12 11.33 8.86 1.22 10.80 8.52 1.33
21.5 14 8.22 8.22 0.47 8.22 8.22 0.48 8.22 8.22 0.49 8.22 8.22 0.51 8.22 8.22 0.50 8.22 8.22 0.49 8.22 8.22 0.49 8.22 8.22 0.49 10.50 10.50 1.01 10.23 10.23 1.11 9.96 9.96 1.21 9.68 9.68 1.31
26.3 15 27 8.96 8.96 0.52 8.96 8.96 0.53 8.96 8.96 0.54 8.96 8.96 0.55 8.96 8.96 0.54 8.96 8.96 0.53 8.96 8.96 0.52 8.96 8.96 0.52 11.28 11.28 1.01 10.89 10.89 1.11 10.51 10.51 1.22 10.12 10.12 1.32
31.3 16 9.70 9.70 0.56 9.70 9.70 0.58 9.70 9.70 0.59 9.70 9.70 0.60 9.70 9.70 0.59 9.70 9.70 0.57 9.70 9.70 0.55 9.70 9.70 0.56 11.84 11.84 1.01 11.40 11.40 1.12 11.03 11.03 1.22 10.58 10.58 1.32
3D098207A

PAIR FHA140 FBQA140 FVA140 FCAHG140 FCAG140 TRIPLE FHQA50 x 3 FBA50 x 3 FDXM50 x 3 FFA50 x 3 FCAG50 x 3
Cooling 2.49 2.49 2.49 2.15 2.45 Cooling 2.98 2.96 2.54 2.70 2.33

TWIN FAA71 x 2 FHA71 x 2 FBA71 x 2 FUA71 x 2 FCAHG71 x 2 FCAG71 x 2 DOUBLE TWIN FHA35 x 4 FBA35 x 4 FDXM35 x 4 FFA35 x 4 FCAG35 x 4
Cooling 2.64 2.94 2.83 2.34 2.14 2.35 Cooling 3.03 3.05 2.58 2.75 2.35

Note : blue cells contain preliminary data

Symbols
TC Maximum total cooling capacity [kW]
SHC Sensible heat capacity [kW]
CPI Coefficient of the power input
PI Power input [kW]
compressor + indoor and outdoor fan motors
RH Relative humidity [%]

100
SKY AIR INTRO
Infrastructure cooling solution

INDOOR
UNITS
Boosted capacity indoors with 12.5kW outdoor system
RZAG125MV1/MY1

Outdoor temperature [°C DB]

OUTDOOR
Indoor -15 -10 -5 0 5 10 15 20 25 30 35 40

UNITS
TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI
RH [%] °CWB °CDB kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW -
54.5 11 16 7.49 6.72 0.33 7.49 6.72 0.34 7.49 6.72 0.35 7.49 6.72 0.36 7.49 6.72 0.37 7.49 6.72 0.38 7.49 6.72 0.38 7.49 6.72 0.38 10.25 8.55 0.98 9.71 8.21 1.08 9.17 7.86 1.18 8.69 7.55 1.27
41.8 11 7.49 7.49 0.33 7.49 7.49 0.34 7.49 7.49 0.35 7.49 7.49 0.36 7.49 7.49 0.37 7.49 7.49 0.38 7.49 7.49 0.38 7.49 7.49 0.38 10.25 9.60 0.98 9.71 9.28 1.08 9.17 8.94 1.18 8.69 8.60 1.27
18
57 13 9.34 7.60 0.42 9.34 7.60 0.43 9.34 7.60 0.44 9.34 7.60 0.45 9.34 7.60 0.45 9.34 7.60 0.45 9.34 7.60 0.45 9.34 7.60 0.45 11.91 9.22 0.99 11.41 8.92 1.09 10.91 8.61 1.19 10.37 8.28 1.28
31.4 11 7.49 7.49 0.33 7.49 7.49 0.34 7.49 7.49 0.35 7.49 7.49 0.36 7.49 7.49 0.37 7.49 7.49 0.38 7.49 7.49 0.38 7.49 7.49 0.38 10.25 10.25 0.98 9.71 9.71 1.08 9.17 9.17 1.18 8.69 8.69 1.27
44.9 13 20 9.34 8.65 0.42 9.34 8.65 0.43 9.34 8.65 0.44 9.34 8.65 0.45 9.34 8.65 0.45 9.34 8.65 0.45 9.34 8.65 0.45 9.34 8.65 0.45 11.91 10.27 0.99 11.41 9.96 1.09 10.91 9.64 1.19 10.37 9.31 1.28
52 14 10.27 8.56 0.46 10.27 8.56 0.47 10.27 8.56 0.49 10.27 8.56 0.50 10.27 8.56 0.49 10.27 8.56 0.49 10.27 8.56 0.48 10.27 8.56 0.48 12.88 10.16 0.99 12.54 10.00 1.09 12.21 9.83 1.19 11.87 9.55 1.29

AIR CURTAINS
22.9 11 7.49 7.49 0.33 7.49 7.49 0.34 7.49 7.49 0.35 7.49 7.49 0.36 7.49 7.49 0.37 7.49 7.49 0.38 7.49 7.49 0.38 7.49 7.49 0.38 10.25 10.25 0.98 9.71 9.71 1.08 9.17 9.17 1.18 8.69 8.69 1.27
34.8 13 9.34 9.34 0.42 9.34 9.34 0.43 9.34 9.34 0.44 9.34 9.34 0.45 9.34 9.34 0.45 9.34 9.34 0.45 9.34 9.34 0.45 9.34 9.34 0.45 11.91 11.91 0.99 11.41 11.41 1.09 10.91 10.91 1.19 10.37 10.37 1.28

BIDDLE
22
47.6 15 11.20 9.34 0.51 11.20 9.34 0.52 11.20 9.34 0.53 11.20 9.34 0.55 11.20 9.34 0.54 11.20 9.34 0.52 11.20 9.34 0.51 11.20 9.34 0.51 13.83 11.06 0.99 13.36 10.78 1.09 12.88 10.49 1.20 12.41 10.20 1.29
54.3 16 12.12 9.00 0.55 12.12 9.00 0.57 12.12 9.00 0.58 12.12 9.00 0.59 12.12 9.00 0.58 12.12 9.00 0.56 12.12 9.00 0.54 12.12 9.00 0.55 14.51 10.10 1.00 13.98 9.89 1.10 13.52 9.67 1.20 12.98 9.35 1.30
21.2 12 8.42 8.42 0.37 8.42 8.42 0.38 8.42 8.42 0.39 8.42 8.42 0.41 8.42 8.42 0.41 8.42 8.42 0.41 8.42 8.42 0.41 8.42 8.42 0.41 11.08 11.08 0.98 10.56 10.56 1.08 10.04 10.04 1.19 9.53 9.53 1.27
32.1 14 10.27 10.27 0.46 10.27 10.27 0.47 10.27 10.27 0.49 10.27 10.27 0.50 10.27 10.27 0.49 10.27 10.27 0.49 10.27 10.27 0.48 10.27 10.27 0.48 12.88 12.88 0.99 12.54 12.54 1.09 12.21 12.21 1.19 11.87 11.87 1.29
24
43.8 16 12.12 10.35 0.55 12.12 10.35 0.57 12.12 10.35 0.58 12.12 10.35 0.59 12.12 10.35 0.58 12.12 10.35 0.56 12.12 10.35 0.54 12.12 10.35 0.55 14.51 11.71 1.00 13.98 11.44 1.10 13.52 11.21 1.20 12.98 10.90 1.30
50 17 12.47 9.38 0.57 12.47 9.38 0.58 12.47 9.38 0.59 12.47 9.38 0.60 12.47 9.38 0.59 12.47 9.38 0.59 12.47 9.38 0.59 12.47 9.38 0.59 15.20 11.36 1.00 14.54 11.02 1.10 13.89 10.66 1.20 13.24 10.25 1.31
21.5 14 10.27 10.27 0.46 10.27 10.27 0.47 10.27 10.27 0.49 10.27 10.27 0.50 10.27 10.27 0.49 10.27 10.27 0.49 10.27 10.27 0.48 10.27 10.27 0.48 12.88 12.88 0.99 12.54 12.54 1.09 12.21 12.21 1.19 11.87 11.87 1.29
26.3 15 27 11.20 11.20 0.51 11.20 11.20 0.52 11.20 11.20 0.53 11.20 11.20 0.55 11.20 11.20 0.54 11.20 11.20 0.52 11.20 11.20 0.51 11.20 11.20 0.51 13.83 13.83 0.99 13.36 13.36 1.09 12.88 12.88 1.20 12.41 12.41 1.29
31.3 16 12.12 12.12 0.55 12.12 12.12 0.57 12.12 12.12 0.58 12.12 12.12 0.59 12.12 12.12 0.58 12.12 12.12 0.56 12.12 12.12 0.54 12.12 12.12 0.55 14.51 14.51 1.00 13.98 13.98 1.10 13.52 13.52 1.20 12.98 12.98 1.30

VENTILATION
3D098208A

PAIR FHA140 FBA140 FVA140 FCAHG140 FCAG140 TRIPLE FHA50 x 3 FBA50 x 3 FDXM50 x 3 FFA50 x 3 FCAG50 x 3
Cooling 3.58 3.63 3.74 3.00 3.22 Cooling 3.66 3.97 3.45 3.23 3.17

TWIN FAA71 x 2 FHA71 x 2 FBA71 x 2 FUA71 x 2 FCAHG71 x 2 FCAG71 x 2 DOUBLE TWIN FHA35 x 4 FBA35 x 4 FDXM35 x 4 FFA35 x 4 FCAG35 x 4
Cooling 3.69 3.67 4.10 3.44 2.97 3.17 Cooling 3.64 3.74 3.94 3.01 3.23

Note : blue cells contain preliminary data


Combinations with 14kW outdoor system

CONTROL
SYSTEMS
RZAG140MV1/MY1
Outdoor temperature [°C DB]
Indoor -15 -10 -5 0 5 10 15 20 25 30 35 40
TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI TC SHC CPI
RH [%] °CWB °CDB kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW - kW kW -
54.5 11 16 8.24 7.27 0.32 8.24 7.27 0.33 8.24 7.27 0.34 8.24 7.27 0.35 8.24 7.27 0.37 8.24 7.27 0.37 8.24 7.27 0.37 8.24 7.27 0.38 10.95 8.87 0.96 10.37 8.51 1.06 9.79 8.15 1.16 9.28 7.83 1.25
41.8 11 8.24 8.24 0.32 8.24 8.24 0.33 8.24 8.24 0.34 8.24 8.24 0.35 8.24 8.24 0.37 8.24 8.24 0.37 8.24 8.24 0.37 8.24 8.24 0.38 10.95 9.96 0.96 10.37 9.62 1.06 9.79 9.27 1.16 9.28 8.92 1.25
18

& ACCESSORIES
57 13 10.28 8.22 0.41 10.28 8.22 0.42 10.28 8.22 0.43 10.28 8.22 0.45 10.28 8.22 0.45 10.28 8.22 0.44 10.28 8.22 0.44 10.28 8.22 0.44 12.72 9.56 0.97 12.18 9.25 1.07 11.65 8.93 1.17 11.07 8.58 1.26

OPTIONS
31.4 11 8.24 8.24 0.32 8.24 8.24 0.33 8.24 8.24 0.34 8.24 8.24 0.35 8.24 8.24 0.37 8.24 8.24 0.37 8.24 8.24 0.37 8.24 8.24 0.38 10.95 10.95 0.96 10.37 10.37 1.06 9.79 9.79 1.16 9.28 9.28 1.25
44.9 13 20 10.28 9.35 0.41 10.28 9.35 0.42 10.28 9.35 0.43 10.28 9.35 0.45 10.28 9.35 0.45 10.28 9.35 0.44 10.28 9.35 0.44 10.28 9.35 0.44 12.72 10.64 0.97 12.18 10.33 1.07 11.65 10.00 1.17 11.07 9.65 1.26
52 14 11.30 9.26 0.45 11.30 9.26 0.47 11.30 9.26 0.48 11.30 9.26 0.49 11.30 9.26 0.49 11.30 9.26 0.48 11.30 9.26 0.47 11.30 9.26 0.47 13.75 10.53 0.97 13.40 10.36 1.07 13.04 10.19 1.17 12.68 9.90 1.27
22.9 11 8.24 8.24 0.32 8.24 8.24 0.33 8.24 8.24 0.34 8.24 8.24 0.35 8.24 8.24 0.37 8.24 8.24 0.37 8.24 8.24 0.37 8.24 8.24 0.38 10.95 10.95 0.96 10.37 10.37 1.06 9.79 9.79 1.16 9.28 9.28 1.25
34.8 13 10.28 10.28 0.41 10.28 10.28 0.42 10.28 10.28 0.43 10.28 10.28 0.45 10.28 10.28 0.45 10.28 10.28 0.44 10.28 10.28 0.44 10.28 10.28 0.44 12.72 12.72 0.97 12.18 12.18 1.07 11.65 11.65 1.17 11.07 11.07 1.26
22
47.6 15 12.32 10.10 0.50 12.32 10.10 0.51 12.32 10.10 0.52 12.32 10.10 0.54 12.32 10.10 0.53 12.32 10.10 0.51 12.32 10.10 0.50 12.32 10.10 0.50 14.77 11.47 0.98 14.26 11.18 1.08 13.76 10.88 1.18 13.25 10.57 1.27
54.3 16 13.33 9.73 0.54 13.33 9.73 0.56 13.33 9.73 0.57 13.33 9.73 0.58 13.33 9.73 0.57 13.33 9.73 0.55 13.33 9.73 0.53 13.33 9.73 0.54 15.50 10.47 0.98 14.93 10.25 1.08 14.44 10.03 1.18 13.86 9.69 1.28
21.2 12 9.26 9.26 0.37 9.26 9.26 0.38 9.26 9.26 0.39 9.26 9.26 0.40 9.26 9.26 0.41 9.26 9.26 0.41 9.26 9.26 0.41 9.26 9.26 0.41 11.83 11.83 0.97 11.28 11.28 1.07 10.72 10.72 1.17 10.17 10.17 1.25
32.1 14 11.30 11.30 0.45 11.30 11.30 0.47 11.30 11.30 0.48 11.30 11.30 0.49 11.30 11.30 0.49 11.30 11.30 0.48 11.30 11.30 0.47 11.30 11.30 0.47 13.75 13.75 0.97 13.40 13.40 1.07 13.04 13.04 1.17 12.68 12.68 1.27
24
43.8 16 13.33 11.20 0.54 13.33 11.20 0.56 13.33 11.20 0.57 13.33 11.20 0.58 13.33 11.20 0.57 13.33 11.20 0.55 13.33 11.20 0.53 13.33 11.20 0.54 15.50 12.14 0.98 14.93 11.86 1.08 14.44 11.62 1.18 13.86 11.30 1.28
& PLATFORMS

50 17 13.72 10.15 0.56 13.72 10.15 0.57 13.72 10.15 0.58 13.72 10.15 0.59 13.72 10.15 0.58 13.72 10.15 0.58 13.72 10.15 0.58 13.72 10.15 0.58 16.23 11.78 0.98 15.53 11.43 1.08 14.83 11.06 1.18 14.14 10.63 1.29
TOOLS

21.5 14 11.30 11.30 0.45 11.30 11.30 0.47 11.30 11.30 0.48 11.30 11.30 0.49 11.30 11.30 0.49 11.30 11.30 0.48 11.30 11.30 0.47 11.30 11.30 0.47 13.75 13.75 0.97 13.40 13.40 1.07 13.04 13.04 1.17 12.68 12.68 1.27
26.3 15 27 12.32 12.32 0.50 12.32 12.32 0.51 12.32 12.32 0.52 12.32 12.32 0.54 12.32 12.32 0.53 12.32 12.32 0.51 12.32 12.32 0.50 12.32 12.32 0.50 14.77 14.77 0.98 14.26 14.26 1.08 13.76 13.76 1.18 13.25 13.25 1.27
31.3 16 13.33 13.33 0.54 13.33 13.33 0.56 13.33 13.33 0.57 13.33 13.33 0.58 13.33 13.33 0.57 13.33 13.33 0.55 13.33 13.33 0.53 13.33 13.33 0.54 15.50 15.50 0.98 14.93 14.93 1.08 14.44 14.44 1.18 13.86 13.86 1.28
3D098209A

PAIR FHA140 FBA140 FVA140 FCAHG140 FCAG140 TRIPLE FHA50 x 3 FBA50 x 3 FDXM50 x 3 FFA50 x 3 FCAG50 x 3
Cooling 4.05 4.00 4.17 4.00 4.17 Cooling 4.25 3.75 4.26 4.15 4.12

TWIN FAA71 x 2 FHA71 x 2 FBA71 x 2 FUA71 x 2 FCAHG71 x 2 FCAG71 x 2 DOUBLE TWIN FHA35 x 4 FBA35 x 4 FDXM35 x 4 FFA35 x 4 FCAG35 x 4
Cooling 3.81 3.59 3.75 3.35 3.94 4.11 Cooling 4.23 3.75 5.38 3.83 4.18
TECHNICAL
DRAWINGS

Note : blue cells contain preliminary data

Notes
1. The ratings shown are net capacities 2. The capacities are based on 3. CPI is a percentage value compared 5. The error rate for this value is less
and include a deduction for indoor the following conditions: to the rated value of 1.00 than 5% and depends on the indoor
fan motor heat. ›› Outdoor air: 85% RH unit type
›› Corresponding refrigerant 4. For infrastructure cooling applications,
PREVIOUS

piping length: 5.0 m it is recommended to use remote 6. The rated power inputs (PI) for each
›› Level difference: 0m controller setting 16(26)-2-03 model are listed in the table above

101
RZAG-MV1/MY1

Sky Air Alpha-series


Industry leading technology for commercial applications
and technical rooms

ʯʯ Top efficiency:
• energy labels up to A++ in both cooling and heating
• compressor offers substantial improvements in efficiency
ʯʯ The perfect balance in efficiency and comfort due to Variable
Refrigerant Temperature: top seasonal efficiency throughout most
of the year and quick reaction speed on the hot days.

ʯʯ For high sensible infrastructure cooling applications


ʯʯ Replace existing systems without having to replace the piping

RZAG100-140MV1/MY1
ʯʯ Extended operation range down to -20°C in heating and cooling
ʯʯ With a gas cooled PCB, reliable cooling is guaranteed, as it is not
influenced by ambient temperature
ʯʯ Maximum piping length up to 85m

Comfort cooling combination table


FDXM-F3
FCAHG-G

FCAG-A

FHA-A

FNA-A
FDA-A

FUA-A
FBA-A

FAA-A

FVA-A
FFA-A

capacity class 71 100 125 140 35 50 60 71 100 125 140 35 50 60 125 35 50 60 35 50 60 71 100 125 140 35 50 60 71 100 125 140 71 100 71 100 125 35 50 60 71 100 125 140
RZAG71MV1 RZAG71MY1 2 P 2 2 2 P 2 P P P 2 P
RZAG100MV1 RZAG100MY1 P 3 2 P 3 2 3 2 3 2 P 3 2 P P P 3 2 P
RZAG125MV1 RZAG125MY1 P 4 3 2 P 4 3 2 P 4 3 2 4 3 2 P 4 3 2 P P 4 3 2 P
RZAG140MV1 RZAG140MY1 2 P 4 3 2 P 4 3 4 3 4 3 2 P 4 3 2 P 2 2 4 3 2 P
P = application ; 2/3/4 = twin/tripple/double twin application

Infrastructure cooling combination table


FCAHG-G
FDXM-F3

FCAG-A
FHA-A

FUA-A

FVA-A
FBA-A

FFA-A
FAA-A

capacity class 71 100 35 50 60 71 100 125 140 35 50 60 71 100 125 140 35 50 60 71 100 125 71 100 125 140 35 50 60 71 100 125 140 35 50 60 71 100 125 140
RZAG71MV1 RZAG71MY1 P 3 2 P 3 2 P 3 2 P P 3 2 P 3 2 P
RZAG100MV1 RZAG100MY1 2 4 3 2 P 4 3 2 P 4 3 2 2 P 4 3 2 P 4 3 2 P
RZAG125MV1 RZAG125MY1 2 4 3 2 P 4 3 2 P 4 3 2 2 P 4 3 2 P 4 3 2 P
RZAG140MV1 RZAG140MY1 2 4 3 2 P 4 3 2 P 4 3 2 2 P 4 3 2 P 4 3 2 P
P = Pair, 2 = Twin, 3 = Triple, 4 = Double twin; For more information on infrastructure cooling options refer to infrastructure cooling catalogue.

More details and final information


can be found our my.daikin.eu RZAG-MV1 RZAG-MY1
Outdoor unit RZAG 71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1
Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 70 92 70 92
Sound power level Cooling dBA 64 66 69 70 65 66 69 70
Sound pressure level Cooling Nom. dBA 46 47 50 51 46 47 50 51
Heating Nom. dBA 49 51 52 49 51 52
Operation range Cooling Ambient Min.~Max. °CDB -20~52
Heating Ambient Min.~Max. °CWB -20~18.0
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.95/1.99 3.75/2.53
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU
Max. m 55 85 55 85
length SystemEquivalent m 75 100 75 100
Chargeless m 40
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

102
SKY AIR INTRO
RZASG-MV1/MY1

Sky Air Advance-series


Technology and comfort combined
for commercial applications

INDOOR
UNITS
ʯʯ High efficiency:
• Energy labels up to A++ (cooling) /A+ (heating)
• compressor offers substantial efficiency improvements
ʯʯ Very compact and easy to install outdoor units
ʯʯ Replace existing systems without having to replace the piping

OUTDOOR
UNITS
ʯʯ Guarantees operation in both heating and cooling mode down to
-15°C
ʯʯ With a gas cooled PCB, reliable cooling is guaranteed, as it is not
influenced by ambient temperature
ʯʯ Maximum piping length up to 50m. RZASG100-140MV1/MY1

AIR CURTAINS
BIDDLE
Pair, twin, triple and double twin application

FCAG-A FFA-A FDXM-F3 FBA-A


capacity class 35 50 60 71 100 125 140 35 50 60 35 50 60 35 50 60 71 100 125 140

VENTILATION
RZASG71MV1 2 P 2 2 2 P

RZASG100MV1 RZASG100MY1 3 2 P 3 2 3 2 P

RZASG125MV1 RZASG125MY1 4 3 2 P 4 3 2 4 3 2 4 3 2 P

RZASG140MV1 RZASG140MY1 4 3 2 P 4 3 4 3 4 3 2 P

FDA-A FHA-A FUA-A FAA-A FVA-A FNA-A


capacity class 125 35 50 60 71 100 125 140 71 100 125 71 100 71 100 125 140 35 50 60

CONTROL
SYSTEMS
RZASG71MV1 2 P P P P 2

RZASG100MV1 RZASG100MY1 3 2 P P P P 3 2

RZASG125MV1 RZASG125MY1 P 4 3 2 P P P 4 3 2

RZASG140MV1 RZASG140MY1 4 3 2 P 2 2 2 P 4 3

& ACCESSORIES
OPTIONS
& PLATFORMS

More details and final information


TOOLS

can be found our my.daikin.eu RZASG-MV1 RZASG-MY1


Outdoor unit RZASG 71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 78 70 77
Sound power level Cooling dBA 65 70 71 73 70 71 73
Sound pressure level Cooling Nom. dBA 46 53 54 53 54
Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -15~46
TECHNICAL
DRAWINGS

Heating Ambient Min.~Max. °CWB -15~15.5


Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
PREVIOUS

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415


Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16 20 16

103
AZAS-MV1/MY1

Sky Air Active-series


Ideal solution for small shops

ʯʯ High efficiency:
• Energy labels up to A+ (cooling) /A (heating)
• compressor offers substantial efficiency improvements
ʯʯ Very compact and easy to install outdoor units
ʯʯ Replace existing systems without having to replace the piping

ʯʯ Guarantees operation in both heating mode down to -15°C and in


cooling mode down to -5°C
ʯʯ With a gas cooled PCB, reliable cooling is guaranteed, as it is not
influenced by ambient temperature
ʯʯ Maximum piping length up to 30m
ʯʯ Exclusively offered in pair applications AZAS71MV1/MY1

Pair application
FCAG-A FBA-A FAA-A

Capacity class 71 100 125 140 71 100 125 140 71 100 125 140

AZAS-MV1 P P P P P P P P P P

AZAS-MY1 P P P P P P P

More details and final information


can be found our my.daikin.eu AZAS-MV1 AZAS-MY1

Outdoor unit AZAS 71M2V1B 100M7V1B 125M7V1B 140M7V1B 100M7Y1B 125M7Y1B 140M7Y1B
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 78 70 77
Sound power level Cooling dBA 65 70 71 73 70 71 73
Sound pressure level Cooling Nom. dBA 46 53 54 53 54
Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -5~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/Gas mm 9.52/15.9
Piping OU - IU Max. m 30
length System Equivalent m 50
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16 20

104
SKY AIR INTRO
RZQG-L9V1/L(8)Y1

Pair, Twin, Triple, double twin


Industry leading technology for commercial applications
and technical rooms

INDOOR
UNITS
ʯʯ Top efficiency:
• energy labels up to A++ in both cooling and heating
• compressor that offers substantial efficiency improvements
• control logic that optimises efficiency at the most frequently
encountered operating conditions and that optimises the
auxiliary modes (when the unit is not active)
• heat exchangers that optimise the refrigerant flow at the most

OUTDOOR
UNITS
frequent operating conditions (temperature and load)
• via improved nominal performances
ʯʯ The perfect balance in efficiency and comfort thanks to Variable
Refrigerant Temperature: top seasonal efficiency throughout most
of the year and quick reaction speed on the hottest days.
RZQG100-125-140L9V1/L(8)Y1

AIR CURTAINS
ʯʯ Extended operation range down to -20°C in heating and down to

BIDDLE
ʯʯ Suits high sensible, infrastructure cooling applications -15°C in cooling
ʯʯ Replace existing R-22 or R-407C systems without having to replace ʯʯ With a gas cooled PCB reliable cooling is guaranteed as it is not
the piping influenced by ambient temperature
ʯʯ Maximum piping length up to 75m, minimum piping length is 5m.

Comfort cooling combination table

VENTILATION
FDXM-F3
FCAHG-G

FCAG-A

FHA-A

FNA-A
FDA-A

FUA-A
FBA-A

FAA-A

FVA-A
FFA-A

capacity class 71 100 125 140 35 50 60 71 100 125 140 35 50 60 125 35 50 60 35 50 60 71 100 125 140 35 50 60 71 100 125 140 71 100 71 100 125 35 50 60 71 100 125 140
RZQG71L9V1 RZQG71L8Y1 2 P 2 2 2 P 2 P P P 2 P
RZQG100L9V1 RZQG100L8Y1 P 3 2 P 3 2 3 2 3 2 P 3 2 P P P 3 2 P
RZQG125L9V1 RZQG125L8Y1 P 4 3 2 P 4 3 2 P 4 3 2 4 3 2 P 4 3 2 P P 4 3 2 P
RZQG140L9V1 RZQG140LY1 2 P 4 3 2 P 4 3 4 3 4 3 2 P 4 3 2 P 2 2 4 3 P

CONTROL
SYSTEMS
P = application ; 2/3/4 = twin/tripple/double twin application

Infrastructure cooling combination table


FCAHG-G
FDXM-F3

FCAG-A
FHA-A

FUA-A

FVA-A
FBA-A

FFA-A
FAA-A

& ACCESSORIES
OPTIONS
capacity class 71 100 35 50 60 71 100 125 140 35 50 60 71 100 125 140 35 50 60 71 100 125 71 100 125 140 35 50 60 71 100 125 140 35 50 60 71 100 125 140
RZQG71L9V1 RZQG71L8Y1 P 3 2 P 3 2 P 3 2 P P 3 2 P 3 2 P
RZQG100L9V1 RZQG100L8Y1 2 4 3 2 P 4 3 2 P 4 3 2 P 4 3 2 P 4 3 2 P
RZQG125L9V1 RZQG125L8Y1 2 4 3 2 P 4 3 2 P 4 3 2 P 4 3 2 P 4 3 2 P
RZQG140L9V1 RZQG140LY1 2 4 3 2 P 4 3 2 P 4 3 2 P 4 3 2 P 4 3 2 P
P = Pair, 2 = Twin, 3 = Triple, 4 = Double twin; For more information on infrastructure cooling options refer to infrastructure cooling catalogue.
& PLATFORMS

Outdoor unit RZQG 71L9V1 125L9V1 100L9V1


140L9V1 71L8Y1 100L8Y1 125L8Y1 140LY1
TOOLS

Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320


Weight Unit kg 69 95 80 101
Sound power level Cooling dBA 64 66 67 69 64 66 67 69
Sound pressure level Cooling Nom. dBA 48 50 51 52 48 50 51 52
Heating Nom. dBA 50 52 53 50 52 53
Night quiet mode Level 1 dBA 43 45 43 45
Operation range Cooling Ambient Min.~Max. °CDB -15~50
Heating Ambient Min.~Max. °CWB -20~15.5
Refrigerant Type R-410A
Charge kg 2.9 4.0 2.9 4.0
TECHNICAL
DRAWINGS

TCO₂eq 6.1 8.4 6.1 8.4


GWP 2,087.5
Piping connections Liquid OD mm 9.52
Gas OD mm 15.9
Piping length OU - IU Max. m 50 75 50 75
System Equivalent m 70 90 70 90
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3N~ / 50 / 380-415
PREVIOUS

Current - 50Hz Maximum fuse amps (MFA) A 25 40 16 25


(1) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

105
RZQSG-L3/9V1/L(8)Y1

Pair, Twin, Triple, double twin


Technology and comfort combined
for commercial applications

ʯʯ Top efficiency:
• Energy labels up to A++ (cooling) /A+ (heating) for
RZQG71/100L9V1 + FCQG71/100F
• compressor that offers substantial efficiency improvements
• control logic that optimises efficiency at the most frequently
encountered operating conditio
ʯʯ Replace existing R-22 or R-407C systems without having to replace
the piping

ʯʯ Guarantees operation in both heating and cooling mode down to


-15°C RZQSG71-100-125L3/9V1
ʯʯ With a gas cooled PCB reliable cooling is guaranteed as it is not
influenced by ambient temperature
ʯʯ Maximum piping length up to 50m, minimum piping length is 5m.

Pair, twin, triple and double twin application

FCAHG-G FCAG-A FFA-A FDXM-F3 FBA-A


capacity class 71 100 125 140 35 50 60 71 100 125 140 35 50 60 35 50 60 35 50 60 71 100 125 140

RZQSG71L3V1 P 2 P 2 2 2 P

RZQSG100L9V1 RZQSG100L8Y1 P 3 2 P 3 2 3 2 3 2 P

RZQSG125L9V1 RZQSG125L8Y1 P 4 3 2 P 4 3 2 4 3 2 4 3 2 P

RZQSG140L9V1 RZQSG140LY1 2 P 4 3 2 P 4 3 4 3 4 3 2 P

FDA-A FHA-A FUA-A FAA-A FVA-A FNA-A


capacity class 125 35 50 60 71 100 125 140 71 100 125 71 100 71 100 125 140 35 50 60

RZQSG71L3V1 2 P P P P 2

RZQSG100L9V1 RZQSG100L8Y1 3 2 P P P P 3 2

RZQSG125L9V1 RZQSG125L8Y1 P 4 3 2 P P P 4 3 2

RZQSG140L9V1 RZQSG140LY1 4 3 2 P 2 2 P 4 3

Outdoor unit RZQSG 71L3V1 100L9V1 125L9V1 140L9V1 100L8Y1 125L8Y1 140LY1
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 990x940x320 1,430x940x320
Weight Unit kg 67 72 74 95 82 101
Sound power level Cooling dBA 65 70 69 70 70 69
Sound pressure level Cooling Nom./Silent operation dBA 49/47 53/- 54/- 53/- 54/- 53/-
Heating Nom. dBA 51 57 58 54 57 58 54
Night quiet mode Level 1 dBA - 49
Operation range Cooling Ambient Min.~Max. °CDB -15.0~46 -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type R-410A
Charge kg 2.75 2.9 4.0 2.9 4.0
TCO₂eq 5.7 6.1 8.4 6.1 8.4
GWP 2,087.5
Piping connections Liquid OD mm 9.52
Gas OD mm 15.9
Piping length OU - IU Max. m 50
System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 15 30.0
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3N~ / 50 / 380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16 20
(1) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

106
SKY AIR INTRO
AZQS-B(8)V1/BY1 / ARXS-L

Outdoor units
Ideal solution for small shops

INDOOR
UNITS
ʯʯ Daikin outdoor units are neat, sturdy and can easily be mounted
on a roof or terrace or simply placed against an outside wall
ʯʯ With a gas cooled PCB reliable cooling is guaranteed as it is not
influenced by ambient temperature
ʯʯ Outdoor units are fitted with either a swing or scroll compressor,
renowned for low noise and high energy efficiency
ʯʯ Exclusively offered for pair applications (capacity from 71 up to 140)
ʯʯ Units optimized for seasonal efficiency give an indication on how

OUTDOOR
UNITS
efficient an air conditioner operates over an entire heating or
cooling season.
ʯʯ With a gas cooled PCB reliable cooling is guaranteed as it is not
influenced by ambient temperature
ʯʯ Daikin outdoor units are neat, sturdy and can easily be mounted
on a roof or terrace or simply placed against an outside wall AZQS100-125B(8)V1/BY1
ʯʯ Outdoor units are fitted with either a swing or scroll compressor,

AIR CURTAINS
renowned for low noise and high energy efficiency

BIDDLE
ʯʯ Exclusively offered for pair applications (capacity from 71 up to 140)
ʯʯ Units optimized for seasonal efficiency give an indication on how
efficient an air conditioner operates over an entire heating or
cooling season.

VENTILATION
CONTROL
SYSTEMS
Pair application
FCAG-A ADEQ-C ABQ-C AHQ-C

Capacity class 71 100 125 140 71 100 125 140 71 100 125 140 71 100 125 140

& ACCESSORIES
combines
AZQS-B(8)V1 P P P P P P P P P P P

OPTIONS
with ARXS

AZQS-BY1 P P P P P P P P P

ARXS AZQS
Outdoor unit ARXS / AZQS 71L 71BV1 100B8V1 125B8V1 140B8V1 100BY1 125BY1 140BY1
& PLATFORMS

Dimensions Unit HeightxWidthxDepth mm 735x825x300 770x900x320 990x940x320 1,430x940x320 990x940x320 1,430x940x320


Weight Unit kg 53 67 72.8 74.3 94.9 82 101
TOOLS

Sound power level Cooling dBA - 64 70 71 70 71 70


Sound pressure level Cooling Nom. dBA - 48 53 54 53 54 53
Heating Nom. dBA - 50 57 58 54 57 58 54
Night quiet mode Level 1 dBA - 43 49
Operation range Cooling Ambient Min.~Max. °CDB +10~46 -5~46
Heating Ambient Min.~Max. °CWB -15~18 -15~15.5
Refrigerant Type R-410A
Charge kg - 2.75 2.9 4.0 2.9 4.0
TCO₂eq - 5.7 6.1 8.4 6.1 8.4
TECHNICAL
DRAWINGS

GWP 2,087.5
Piping connections Liquid OD mm 9.52
Gas OD mm 15.9
Piping length OU - IU Max. m 30 50 50
System Equivalent m - 70 40 for combinations with FCQG
Chargeless m 10 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 20.0 30.0
Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3N~ / 50 / 380-415
PREVIOUS

Current - 50Hz Maximum fuse amps (MFA) A - 20 32 40 16 20 25


(1) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

107
RZQ-C

Pair, Twin, Triple, double twin


Packaged system for commercial applications

ʯʯ Available as 20 and 25kW


ʯʯ Replace existing R-22 or R-407C systems without having to replace
the piping

ʯʯ Guarantees operation in heating mode down to -15°C


ʯʯ Standard night quiet mode
ʯʯ Maximum piping length up to 100m
ʯʯ Maximum installation height difference up to 30m
ʯʯ Wide range of connectable indoor units

RZQ200-250C

Pair, twin, triple and double twin application


FCAG-A FFA-A FDXM-F3 FBA-A FHA-A FDQ-B FUA-A FAA-A FDA-A FNA-A
capacity class 50 60 71 100 125 50 60 50 60 50 60 71 100 125 50 60 71 100 125 200 250 71 100 125 71 100 125 50 60
RZQ200C 4 3 3 2 4 3 4 3 4 3 3 2 4 3 3 2 P 3 2 3 2 4 3
RZQ250C 4 2 4 4 4 4 2 2 P 2 2 4

Outdoor unit RZQ 200C 250C


Dimensions Unit HeightxWidthxDepth mm 1,680x930x765
Weight Unit kg 183 184
Sound power level Cooling dBA 78
Heating dBA 78
Sound pressure level Nom. dBA 57
Operation range Cooling Ambient Min.~Max. °CDB -5.0~46.0
Heating Ambient Min.~Max. °CWB -15.0~15.0
Refrigerant Type R-410A
Charge kg 8.3 9.3
TCO₂eq 17.3 19.4
GWP 2,087.5
Piping connections Liquid OD mm 9.52 12.7
Gas OD mm 22.20
Piping length OU - IU Max. m 100
Level difference IU - OU Max. m -
Power supply Phase / Frequency / Voltage Hz / V 3N~ / 50 / 380-415
Current - 50Hz Maximum fuse amps (MFA) A 20
(1) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

108
SKY AIR INTRO
Multi model

INDOOR
applications

UNITS
OUTDOOR
UNITS
• All indoor units can be individually controlled and do not need to be

AIR CURTAINS
installed in the same room.

BIDDLE
• Combine different types of indoor units: wall mounted, floor standing,
ceiling suspended, round flow cassette, concealed ceiling.
• Phased installation possible.

VENTILATION
MXS /MXM RXYS(C)Q
Installation flexibility Installation flexibility
›› A very wide range is available, from 2-port ›› Up to 9 indoor units can be connected
to 5-port units, making all applications possible. to 1 VRV outdoor unit
›› Up to 5 indoor units can be connected to ›› Maximum total piping length of 145m offers

CONTROL
SYSTEMS
1 multi outdoor unit. much more flexibility in the choice of installation
›› Outdoor multi split units are fitted with position
the Daikin swing compressor, renowned for its low
noise and high energy efficiency.
›› The outdoor units are neat and sturdy and can be
mounted easily on a roof or terrace or simply placed
against an outside wall.

& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS

BP

BP
TECHNICAL
DRAWINGS

BP Refnet

5MXS90E RXYSQ4-6TV1
PREVIOUS

109
Biddle air curtains
Biddle air curtains provide highly efficient
solutions for retailers and consultants to
combat the issue of climate separation across
their outlet or office doorway.

110
SKY AIR INTRO
Biddle air curtains

Outdoor units portfolio for connection


to Biddle air curtains

INDOOR
UNITS
System Type Product name Condensing units 71 100 125 140 200 250

ERQ-AV1 1
Condensing Units
- High efficiency
- High comfort levels
  
Air cooled Heat pump - Easy design and installation
ERQ-AW1 - Maximize installation flexibility by
  
1

Condensing Units offering 4 types of control systems

OUTDOOR
UNITS
1) Only use the condensing units in combinations with an air handling unit.

Biddle air curtain portfolio

AIR CURTAINS
3.0m
3 2.75m

BIDDLE
2.5m 2.4m 2.5m
Door height (m) 2.3m 2.3m
2.15m
2.0m
2

VENTILATION
S M L S M L S M L

Installation condition
Favourable Normal Unfavourable
ex: covered shopping mall or ex: little direct wind, no ex: location at a corner or
revolving door entrance opposite open doors, building square, multiple floors and / or
with ground floor only open stairwell

CONTROL
SYSTEMS
Type Product name Features
- CYQ - Biddle air curtain for connection to ERQ
Biddle standard air curtain
CYQ S/M/L-DK-F - Connectable to ERQ heat pump
free hanging
- Cassette model (C): mounted into a false ceiling leaving only the decoration
panel visible
Biddle standard - Free-hanging model (F): easy wall mounted installation
CYQ S/M/L-DK-C
air curtain cassette
- Recessed model (R): neatly conceiled in the ceiling

& ACCESSORIES
- A payback period of less than 1.5 years compared to installing an electric air curtain

OPTIONS
Biddle standard
CYQ S/M/L-DK-R - Easy and quick to install at reduced costs since no additional water systems,
air curtain recessed
boilers and gas connections are required

& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

111
CYQS/M/L-DK-F/C/R

Biddle air curtain for ERQ


›› Connectable to ERQ heat pump
›› ERQ is among the first DX systems suitable for connection to air
curtains
›› Free-hanging model (F): easy wall mounted installation
›› Cassette model (C): mounted into a false ceiling leaving only the
decoration panel visible
›› Recessed model (R): neatly concealed in the ceiling
›› A payback period of less then 1.5 years compared to installing an CYQM150DK80FSN
electric air curtain
›› Easy and quick to install at reduced costs since no additional water
systems, boilers and gas connections are required
›› Maximum energy efficiency stemming from almost zero down flow
turbulence, optimised air flow and the application of advanced
discharge rectifier technology
›› Around 85% air separation efficiency, greatly reducing both heat
loss and required indoor unit heating capacity CYQM150DK80CSN CYQM150DK80RSN

Packtime of less than 1.5 years


electric air curtain

12000

10000
(installation + running cost) in €

8000
Daikin heat pump
with Biddle air curtain*
total cost

6000

4000

2000

0
1 2 years

Small Medium
CYQS150DK80 CYQS200DK100 CYQS250DK140 CYQM100DK80 CYQM150DK80 CYQM200DK100 CYQM250DK140
*BN/*SN *BN/*SN *BN/*SN *BN/*SN *BN/*SN *BN/*SN *BN/*SN
Heating capacity Speed 3 kW 9.0 11.6 16.2 9.2 11.0 13.4 19.9
Power input Fan only Nom. kW 0.35 0.46 0.58 0.37 0.56 0.75 0.94
Heating Nom. kW 0.35 0.46 0.58 0.37 0.56 0.75 0.94
Delta T Speed 3 K 15 16 17 14 13 15
Casing Colour BN: RAL9010 / SN: RAL9006
Dimensions Unit Height F/C/R mm 270/270/270
Width F/C/R mm 1,500/1,500/1,548 2,000/2,000/2,048 2,500/2,500/2,548 1,000/1,000/1,048 1,500/1,500/1,548 2,000/2,000/2,048 2,500/2,500/2,548
Depth F/C/R mm 590/821/561
Required ceiling void > mm 420
Door height Max. m 2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3)
Door width Max. m 1.5 2.0 2.5 1.0 1.5 2.0 2.5
Weight Unit kg 66 83 107 57 73 94 108
Fan-Air flow rate Heating Speed 3 m³/h 1,746 2,328 2,910 1,605 2,408 3,210 4,013
Sound pressure level Heating Speed 3 dBA 49 50 51 50 51 53 54
Refrigerant Type / GWP R-410A / 2,087.5
Piping connections Liquid/OD/Gas/OD mm 9.52/16.0 9.52/19.0 9.52/16.0 9.52/19.0
Required accessories (should be ordered separately) Daikin wired remote control (BRC1E52A/B or BRC1D52)
Power supply Voltage V 230

Large
CYQL100DK125 CYQL150DK200 CYQL200DK250 CYQL250DK250
*BN/*SN *BN/*SN *BN/*SN *BN/*SN
Heating capacity Speed 3 kW 15.6 23.3 29.4 31.1
Power input Fan only Nom. kW 0.75 1.13 1.50 1.88
Heating Nom. kW 0.75 1.13 1.50 1.88
Delta T Speed 3 K 15 14 12
Casing Colour BN: RAL9010 / SN: RAL9006
Dimensions Unit Height F/C/R mm 370/370/370
Width F/C/R mm 1,000/1,000/1,048 1,500/1,500/1,548 2,000/2,000/2,048 2,500/2,500/2,548
Depth F/C/R mm 774/1,105/745
Required ceiling void > mm 520
Door height Max. m 3.0 (1) / 2.75 (2) / 2.5 (3) 3.0 (1) / 2.75 (2) / 2.5 (3) 3.0 (1) / 2.75 (2) / 2.5 (3) 3.0 (1) / 2.75 (2) / 2.5 (3)
Door width Max. m 1.0 1.5 2.0 2.5
Weight Unit kg 76 100 126 157
Fan-Air flow rate Heating Speed 3 m³/h 3,100 4,650 6,200 7,750
Sound pressure level Heating Speed 3 dBA 53 54 56 57
Refrigerant Type / GWP R-410A / 2,087.5
Piping connections Liquid/OD/Gas/OD mm 9.52/16.0 9.52/19.0 9.52/22.0
Required accessories (should be ordered separately) Daikin wired remote control (BRC1E52A/B or BRC1D52)
Power supply Voltage V 230
(1) Favorable conditions: covered shopping mall or revolving door entrance (2) Normal conditions: little direct wind, no opposite open doors, building with ground floor only (3) Unfavorable conditions: location
at a corner or square, multiple floors and/or open stairway

112
SKY AIR INTRO
INDOOR
UNITS
OUTDOOR
UNITS
Ventilation

AIR CURTAINS
BIDDLE
Heat Reclaim ventilation 115

VENTILATION
Modulates the temperature
and humidity of incoming fresh air

VAM-FC 116
VH - electrical heater 118

CONTROL
SYSTEMS
Air Handling unit applications 119

Fresh air solution for buildings


with large ventilation requirements

ERQ 124
Overview & control possibilities 126

& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

113
Ventilation

VAM - HEAT RECLAIM VENTILATION

DAIKIN AIR HANDLING UNIT AND ERQ/VRV HEAT PUMP

114
SKY AIR INTRO
Ventilation

Outdoor units portfolio


for connection to air handling units

INDOOR
UNITS
System Type Product name Condensing units 71 100 125 140 200 250

ERQ-AV1 1
Condensing Units - High efficiency   

OUTDOOR
- High comfort levels

UNITS
Air cooled Heat pump - Easy design and installation
- Maximize installation flexibility by
ERQ-AW1 1 offering 4 types of control systems
Condensing Units   

1) Only use the condensing units in combinations with an air handling unit.

AIR CURTAINS
BIDDLE
Ventilation portfolio Ventilation

VENTILATION
Five components of indoor air quality

›› Ventilation: ensures the provision of fresh air


Heat recovery Humidification
›› Heat recovery: recovers heat and moisture from the outgoing
air to maximise comfort and efficiency
›› Air processing: heats or cools incoming fresh air maximis-
ing comfort and minimizing the load on the air conditioning
installation

CONTROL
Air

SYSTEMS
›› Humidification: optimises the balance between indoor and
outdoor humidity Filtration
›› Filtration: removes dust, pollution and odours from the air
processing

& ACCESSORIES
150 500 1,000 2,000 2,500 15,000 25,000 [m3/h] OPTIONS

›› High efficiency heat exchange


Heat recovery

D-AHU MODULAR R
& PLATFORMS

›› Eurovent energy class A+


TOOLS

›› Compact size
›› Extensive airflow
VAM-FC ›› High energy efficient
paper
›› EC fan motors

NEW
TECHNICAL
DRAWINGS

ADT-FDI - Pre-sized fresh air solution ›› 16 pre-sized combinations (OU&AHU)


Air processing

›› Simple ordering process


›› Quick selection in VRV xpress

D-AHU Modular R with DX connection ›› Plug&play


›› Fully customizable
PREVIOUS

›› 4 types of control
115
VAM-FC

Heat reclaim ventilation Total heat


Clean outdoor air
exchanged
foul air
Ventilation with heat recovery as standard

ʯʯ Energy saving ventilation using indoor heating, cooling and


moisture recovery
ʯʯ Ideal solution for shops, restaurants or offices requiring maximum
floor space for furniture, decorations and fittings
Total heat
ʯʯ Free cooling possible when outdoor temperature is below indoor
exchanged
temperature (eg. during nighttime)
clean air
ʯʯ Reduced energy consumption thanks to specially developed DC Foul indoor air
fan motor
ʯʯ Prevent energy losses from over-ventilation while improving
indoor air quality with optional CO2 sensor
ʯʯ Can be used as stand alone or integrated in the Sky Air or VRV
system
ʯʯ Wide range of units: air flow rate from 150 up to 2,000 m³/h High efficiencies filters available
ʯʯ Optional medium and fine dust filters M6, F7, F8 to meet customer in M6, F7, F8 grades
request or legislation
ʯʯ Shorter installation time thanks to easy adjustment of nominal
air flow rate, so less need for dampers compared with traditional ʯʯ No drain piping needed
installation. ʯʯ Can operate in over- and under pressure
ʯʯ Specially developed heat exchange element with High Efficiency ʯʯ Total solution for fresh air with Daikin supply of both VAM / VKM
Paper (HEP) and electrical heaters

Prevent energy losses from over ventilation with CO2 sensor

Enough fresh air is needed to create an enjoyable environment, but ventilating constantly is leading to energy waste. Therefore an optional
CO2 sensor can be installed which throttles or even switches off the ventilation system when there is enough fresh air in the room, thus
saving energy.

Example of CO2 sensor operation in a meeting room:

9 AM 12 PM 5 PM
Decrease in air volume and more energy
saving compared to fixed ventilation rate

Increase in air
volume and
better comfort
compared to fixed When many people are in the room,
ventilation rate more fresh air is brought in to maintain
comfortable CO2 levels. When fewer
people are in the room, energy is saved
by bringing in less fresh air.

7 8 9 10 11 12 13 14 15 16 17 18 19 hour

Morning meeting Lunch time Meeting


CO2 level
Fixed ventilation rate
Ventilation amount

Using CO2 sensors has the most energy-saving potential in buildings where occupancy fluctuates during a 24-hour period, is unpredictable and peaks at a high level. For example
office buildings, government facilities, retail stores and shopping malls, movie theaters, auditoriums, schools, entertainment clubs and nightclubs. The ventilation unit's reaction to
fluctuations in CO2 can be easily adjusted through a field setting.

116
SKY AIR INTRO
INDOOR
UNITS
OUTDOOR
UNITS
Heat recovery ventilation

High Efficiency Paper

AIR CURTAINS
OUTDOOR INDOOR

BIDDLE
Operation of the high SA
efficiency paper. 27.4°C SA
63% RH Temperature
30.6°C and humidity is
62% RH exhanged between
Cross flow of air to
the layers RA
exchange heat and 32°C RA
moisture. 70% RH 26°C
50% RH
Integrally-formed liner

VENTILATION
RH: Relative Humidity SA: Supply Air (to room) RA: Return Air (from room)

Ventilation VAM 150FC 250FC 350FC 500FC 650FC 800FC 1000FC 1500FC 2000FC
Power input - 50Hz Heat exchange mode Nom. Ultra high/ kW 0.132/0.111/ 0.161/0.079/0.071 (1)/0.057 0.147 (1)/0.101 0.188 (1)/0.114 0.320 (1)/0.241 (1) 0.360 (1)/0.309 (1) 0.617 (1)/0.463 (1) 0.685 (1)/0.575 (1)
High/Low 0.058 0.064 (1)/0.020 (1) (1)/0.049 (1) (1)/0.063 (1) / 0.185 (1) /0.198 (1) /0.353 (1) /0.295 (1)
Bypass mode Nom. Ultra high/ kW 0.132/0.111/ 0.161/0.079/0.071 (1)/0.057 (1)/ 0.147 (1)/0.101 (1)/ 0.188 (1)/0.114 (1)/ 0.320 (1)/0.241 (1)/ 0.360 (1)/0.309 (1)/ 0.617 (1)/0.463 (1)/ 0.685 (1)/0.575 (1)/
High/Low 0.058 0.064 0.020 (1) 0.049 (1) 0.063 (1) 0.185 (1) 0.198 (1) 0.353 (1) 0.295 (1)
Temperature Ultra high/High/Low % 77.0 (2) / 72.0 (3) / 74.9 (2) / 69.5 (3) /
78.0 (2) / 71.6 (4) / 77.0 (2) / 70.2 (4) / 77.0 (2) / 69.8 (4) / 77.0 (2) / 67.8 (4) / 78.0 (2) / 70.2 (4) / 78.0 (2) / 69.5 (4) / 78.0 (2) / 70.2 (4) /
exchange efficiency 78.3 (2) / 72.3 (3) 76.0 (2) / 70.0 (3) /
79.3 (2) / 71.9 (4) / 78.8 (2) / 70.7 (4) / 79.1 (2) / 71.2 (4) / 78.2 (2) / 68.8 (4) / 78.6 (2) / 71.1 (4) / 79.6 (2) / 70.3 (4) / 79.6 (2) / 71.3 (4) /

CONTROL
SYSTEMS
- 50Hz /82.8 (2) /73.2 (3) 80.1 (2) / 72.0 (3)
84.1 (2) / 73.0 (4) 80.9 (2) / 71.3 (4) 81.1 (2) / 72.9 (4) 79.1 (2) / 69.6 (4) 80.2 (2) / 73.4 (4) 80.8 (2) / 71.0 (4) 80.6 (2) / 74.6 (4)
Enthalpy exchange Cooling Ultra high/High/Low % 60.3 (2)/61.9 (2)/ 60.3 (2)/61.2 (2)/
63.4 (2)/65.0 (2)/ 60.3 (2)/63.4 (2)/ 60.3 (2)/64.0 (2)/ 62.4 (2)/63.6 (2)/ 63.4 (2)/64.2 (2)/ 63.4 (2)/65.0 (2)/ 63.4 (2)/64.5 (2)/
efficiency - 50Hz 67.3 (2) 64.5 (2) 70.7 (2) 66.9 (2) 67.3 (2) 64.6 (2) 66.3 (2) 66.2 (2) 67.8 (2)
Heating Ultra high/High/Low % 66.6 (2)/67.9 (2)/ 67.6 (2)/68.9 (2)/ 64.5 (2)/67.6 (2)/ 65.5 (2)/67.7 (2)/ 67.6 (2)/68.8 (2)/ 68.6 (2)/69.4 (2)/
66.6 (2)/67.4 (2)/ 68.6 (2)/69.7 (2)/ 68.6 (2)/69.5 (2)/
72.4 (2) 70.7 (2) 73.7 (2) 71.1 (2) 69.7 (2) 69.8 (2) 71.5 (2) 70.5 (2) 72.1 (2)
Operation mode Heat exchange mode, bypass mode, fresh-up mode
Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange
Heat exchange element Specially processed non-flammable paper
Dimensions Unit HeightxWidthxDepth mm 285x776x525 301x828x816 364x1,000x868 364x1,000x1,160 726x1,510x868 726x1,510x1,160

& ACCESSORIES
Weight Unit kg 24.0 33.0 51.0 54.0 63.0 128 145

OPTIONS
Casing Material Galvanised steel plate
Fan-Air flow rate Heat exchange mode Ultra high/High/Low m³/h 150 (5)/140 250 (5)/230 350 (1)/320 500 (1)/410 650 (1)/545 800 (1)/725 1,000 (1)/950 1,500 (1)/1,350 2,000 (1)/1,880 (1)
- 50Hz (5)/105 (5) (5)/155 (5) (1)/210 (1) (1)/310 (1) (1)/450 (1) (1)/665 (1) (1)/820 (1) (1)/1,230 (1) /1,500 (1)
Bypass mode Ultra high/High/Low m³/h 150 (5)/140 250 (5)/230 350 (1)/320 500 (1)/410 650 (1)/545 800 (1)/725 1,000 (1)/950 1,500 (1)/1,350 2,000 (1)/1,880 (1)
(5)/105 (5) (5)/155 (5) (1)/210 (1) (1)/310 (1) (1)/450 (1) (1)/665 (1) (1)/820 (1) (1)/1,230 (1) /1,500 (1)
Fan-External static Ultra high/High/Low Pa 90 (5)/87 (5)/ 70 (5)/63 (5)/ 103 (1)/93 (1)/ 83 (1)/57 (1)/ 100 (1)/73 (1)/ 109 (1)/94 (1)/ 147 (1)/135 (1)/ 116 (1)/97 (1)/ 132 (1)/118 (1)/
pressure - 50Hz 40 (5) 25 (5) 51 (1) 35 (1) 49 (1) 78 (1) 100 (1) 80 (1) 77 (1)
Air filter Type Multidirectional fibrous fleeces
Sound pressure level Heat exchange mode Ultra high/High/Low dBA 27.0/26.0/20.5 28.0/26.0/21.0 32.0/31.5/23.5 33.0/31.5/24.5 34.5/33.0/27.0 36.0/34.5/31.0 36.0/35.0/31.0 39.5/38.0/34.0 40.0/38.0/35.0
- 50Hz Bypass mode Ultra high/High/Low dBA 27.0/26.5/20.5 28.0/27.0/21.0 32.0/31.0/24.5 33.5/32.5/25.5 34.5/34.0/27.0 36.0/34.5/31.0 36.0/35.5/31.0 40.5/38.0/33.5 40.0/38.0/35.0
& PLATFORMS

Operation range Min. °CDB -15


TOOLS

Max. °CDB 50
Relative humidity % 80% or less
Connection duct diameter mm 100 150 200 250 350
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Current Maximum fuse amps (MFA) A 15.0 16.0
Specific energy Cold climate kWh/(m².a) -56.0 (6) -60.5 (6) -
consumption (SEC) Average climate kWh/(m².a) -22.1 (6) -27.0 (6) -
Warm climate kWh/(m².a) -0.100 (6) -5.30 (6) -
SEC class
TECHNICAL
DRAWINGS

D / (6) B / (6) -

Maximum flow rate at Flow rate m³/h 130 (5) 207 (5) -
100 Pa ESP Electric power input W 129 160 -
Sound power level (Lwa) dB 40 43 48 50 51 53 55 57
Annual electricity consumption kWh/a 18.9 (6) 13.6 (6) -
Annual heating saved Cold climate kWh/a 41.0 (6) 40.6 (6) -
Average climate kWh/a 80.2 (6) 79.4 (6) -
Warm climate kWh/a 18.5 (6) 18.4 (6) -
(1) Measured on fan curve 15. Refer to fan curves. (2) Measured according to JIS B 8628 (3) Measured at reference flow rate according to EN13141-7 (4) Measured according to EN308 : 1997 (5) Clean the filter when
PREVIOUS

the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit‘s energy efficiency. (6) In accordance with commission regulation (EU) No 1254/2014 |
In accordance with commission regulation (EU) No 1253/2014 | At reference flow rate in accordance with commission regulation (EU) No 1254/2014

117
Electrical heater for VAM

VH
›› Total solution for fresh air with Daikin supply of both VAM
and electrical heaters
›› Increased comfort in low outdoor temperature thanks
to the heated outdoor air
›› Integrated electrical heater concept (no additional accessories
required)
›› Standard dual flow and temperature sensor
›› Flexible setting with adjustable setpoint
›› Increased safety with 2 cut-outs: manual & automatic
›› BMS integration thanks to:
- Volt free relay for error indication
- 0-10VDC input for setpoint control

ELECTRICAL HEATER FOR VAM VH (VH)


Supply voltage 220/250V ac 50/60 Hz. +/-10%
Output current (maximum) 19A at 40°C (ambient)
Temperature sensor 5k ohms at 25°C (table 502 1T)
Temperature control range 0 to 40°C / (0-10V 0-100%)
Control fuse 20 x 5mm 250mA
LED indicators Power ON - Yellow
Heater ON - Red (solid or flashing, indicating pulsed control)
Airflow fault - Red
Mounting holes 98mm x 181mm centres 5 mm ø holes
Maximum ambient adjacent to terminal box 35°C (during operation)
Auto high temp. cutout 100°C Pre-set
Man. reset high temp. cutout 125°C Pre-set
Run relay 1A 120V AC or 1A 24V DC
BMS setpoint input 0-10VDC

VH 1B 2B 3B 4B 4/AB 5B
Capacity kW 1 1 1 1.5 2.5 2.5
Duct diameter mm 100 150 200 250 250 300
Connectable VAM VAM150FC VAM250FC VAM500FC VAM800FC VAM800FC VAM1500FC
- VAM350FC VAM650FC VAM1000FC VAM1000FC VAM2000FC
For the selection of the appropriate capacity, please refer to the VAM selection software.

118
SKY AIR INTRO
Daikin
air handling units solutions

INDOOR
UNITS
You will find your match

Why choose Daikin air handling units with a DX connection?

OUTDOOR
UNITS
AIR CURTAINS
BIDDLE
VENTILATION
Simplifying business One stop shop

The unique total solution approach by Daikin helps Daikin is the only global manufacturer in the market
businesses to propose better cross-pillar solutions, to capable of offering a true plug & play solution
increase their success ratio by providing unmatchable where Daikin AHUs manufactured by Daikin Applied
product combinations to the end-user and to simplify Europe and certified by Eurovent, offer off-the-shelf
the life of installers by supplying high-quality products compatibility with Daikin’s unique VRV outdoor unit
coming from the same manufacturer. Contrary to other range for the best performance in the market.

CONTROL
SYSTEMS
manufacturers, Daikin does not use OEM products in its This unique integration of cross-pillar products under
AHU with DX offer. Many competitors are either offering the same umbrella, gives the costumer both peace-of-
OEM DX outdoor units or OEM AHU which create mind and added value when promoting a total solution
additional problems when warranties or faults arise. approach.
Having a single interface for your business makes
Daikin the right choice. Complete range of possibilities

& ACCESSORIES
Supporting tools Thanks to the most complete offer in the market,

OPTIONS
Daikin has the solution for all types of commercial
Selecting an AHU in combination with a DX unit has applications requiring fresh air. Daikin provides
never been this easy amongst manufacturers. The well ventilation solutions based on AHU from 2,500 m3/h
known VRV xpress selection software has been modified up to 140,000 m3/h either with natural heat recovery
to integrate pre-sized AHU combinations with or more advanced ventilation solutions where a
DX outdoor units or just to select outdoor units VRV outdoor unit can be connected to the Daikin
connected to expansion valve kits. AHU for ultimate climate control. The harmonized
& PLATFORMS

If a more complex selection is required, then the new control between the VRV outdoor unit and the AHU
TOOLS

Astra web can be utilized to make unique tailor-made offer outstanding 24h/7 control of the system when
solutions for any project requirements. connected to an iTM.

Advantages
TECHNICAL
DRAWINGS

›› Unique manufacturer offering a complete range


›› Plug&play solution
Easy selection in ›› Direct iTM compatibility
Xpress ›› VRV xpress supporting AHU business NEW
›› Pre-sized AHU+DX outdoor units for fresh air NEW
PREVIOUS

119
Pre-sized fresh air unit

New pre-sized fresh


air solution

Order AHU
and outdoor
in one step

Easy selection Easy ordering


›› 16 pre-selected combinations – to cover all fresh ›› AHU and outdoor unit are automatically selected
air needs in Europe in VRV xpress
›› The right outdoor unit and the necessary con-
nection kits to the coil of the AHU are factory Easy installation
mounted and configured. ›› Same pipe diameter from AHU to outdoor unit
›› Total solution – Daikin provides the complete ›› Direct integration in
solution

Fast quotation
›› Select as any other unit in Xpress selection soft-
ware and show the solution in the report
ENERGY EFFICIENCY
XXX

2016

Download Xpress now with the


new pre-sized combination from
my.daikin.eu Report to performance data

More details in the dedicated brochure


120
SKY AIR INTRO
ADT-FDI Pre-selected fresh air unit

Pre-sized fresh air solution


High end ventilation with heat recovery

INDOOR
UNITS
ʯʯ Pre-sized making selection, quotation, ordering easy
ʯʯ Connects direclty to pre-selected Daikin DX outdoor units
ʯʯ IE premium effciency motor
ʯʯ High effciency heat wheel (heat recovery)
ʯʯ Compact design
ʯʯ Indoor air quality compliant with VDI hygiene guideline
ʯʯ Operating limits from - 20°C up to +46 °C ambient temperature

OUTDOOR
UNITS
ʯʯ Direct integration in intelligent Touch Manager for monitoring
and control

AIR CURTAINS
BIDDLE
ADT03FDI-80 ADT03FDI-100 ADT03FDI-125 ADT04FDI-125 ADT04FDI-140 ADT04FDI-200 ADT05FDI-200 ADT05FDI-250

Airflow Nominal Air Flow valid for m3/h


2,200 2,700 3,200 3,600 4,100 4,700 5,500 6,200

VENTILATION
Cooling (1) and Heating(2)
Expansion Type EKEXV80 EKEXV100 EKEXV125 EKEXV125 EKEXV140 EKEXV200 EKEXV200 EKEXV250
valve kit Number 1
Control box Type EKEQFCBA
Number 1
Outdoor unit Type ERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ200AW1 ERQ250AW1
Number 1
Energy Rating Eurovent Energy Class A+ A A+ A A+ A
ERP Compliance ErP 2018
Heat Recovery Winter Nom. %
Sorption Heat Wheel
Technology

CONTROL
SYSTEMS
Heat Recovery Winter Nom. %
81.5 79.2 76.9 81.1 79.6 77.8 79 77.4
Technology
ESP Nom. Pa 200
SFPv Nom. W/(m3/s) 1,388 1,508 1,660 1,402 1,512 1,637 1,456 1,575
Supply Fan power input Nom. W 0.53 0.7 0.92 0.89 1.08 1.35 1.4 1.72
Filter class Supply F7+ F7
Extract F7+ F7
Dimensions Unit Height mm 1,540 1740
Width mm 2,500 2,620 2,780
Depth mm 990 1,200 1,400

& ACCESSORIES
Weight Kg 549 659 840

OPTIONS
Total Power Input Nom. kW 1,55 2 2,3 2.25 2.63 3.15 3.25 3.86
Power supply Electrical voltage V/ph/Hz 230V/1Ph/50Hz 400V/3Ph/50Hz
Door opening (following supply air direction) Right

ADT06FDI-250 ADT07FDI-250 ADT07FDI-140 ADT07FDI-200 ADT08FDI-200 ADT09FDI-200 ADT09FDI-250 ADT10FDI-250

Airflow Nominal Air Flow valid for m3/h


6,900 7,400 8,000 8,700 10,000 11,500 13,200 14,900
Cooling (1) and Heating(2)
Expansion Type EKEXV250 EKEXV140 EKEXV200 EKEXV250 EKEXV250
valve kit Number 1 2
& PLATFORMS

Control box Type EKEQFCBA


Number 1 2
TOOLS

Outdoor unit Type ERQ250AW1 ERQ140AV1 ERQ200AW1 ERQ250AW1


Number 1 2 2 2
Energy Rating Eurovent Energy Class A A+ A A+ A A+
ERP Compliance ErP 2018
Heat Recovery Winter Nom. %
Sorption Heat Wheel
Technology
Heat Recovery Winter Nom. %
77.9 80.2 79.3 78.1 78.4 79.7 77.9 80.2
Technology
ESP Nom. Pa 200
TECHNICAL

SFPv Nom. W/(m3/s) 1,580 1,438 1,491 1,581 1,429 1,438 1,569 1,397
DRAWINGS

Supply Fan power input Nom. W 1.86 1.82 2.04 2.35 2.48 2.82 3.54 3.62
Filter class Supply F7+ F7
Extract F7+ F7
Dimensions Unit Height mm 1920 2,180 2,460 2,570
Width mm 2,980 3,100 3,150 2,980 3,100
Depth mm 1,400 1,600 1940 2,300
Weight Kg 887 1,063 1,489 1,594 1,973
Total Power Input Nom. kW 4.14 4.07 4.48 5.08 5.37 6.06 7.44 7.6
Power supply Electrical voltage V/ph/Hz 400V/3Ph/50Hz
Door opening (following supply air direction) Right
PREVIOUS

(1) Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
(2) Heating: indoor temp. 20°CDB; outdoor temp. -15°CDB; equivalent refrigerant piping: 5m; level difference: 0m

121
Air handling unit applications

Why use ERQ condensing units for connection


to air handling units?
High Efficiency
Daikin heat pumps are renowned for their high
energy efficiency. Integrating the AHU with a heat inside in an unconditioned state. In this case heat
recovery system is even more effective since from the offices is merely transferred to heat up
an office system can frequently be in cooling mode the cold incoming fresh air.
while the outdoor air is too cold to be brought

Outside air = 10°C

Fresh air supplied at 21°C.


The temperature difference with
the outdoor air is heated up for free
by heat recovery via A/C system

Indoor temperature 22°C,


needs cooling because of solar
radiation.
The excessive heat can be
transferred to the AHU.

Fast response to changing loads Easy Design and Installation


resulting in high comfort levels The system is easy to design and install since
Daikin ERQ units respond rapidly no additional water systems such as boilers,
to fluctuations in supply air temperature, resulting tanks and gas connections etc. are required.
in a steady indoor temperature and resultant high This also reduces both the total system investment
comfort levels for the end user. The ultimate is and running cost.
the VRV range which improves comfort even more
by offering continuous heating, also during defrost.

Daikin Fresh air package

VRV IV or ERQ condensing unit

Factory fitted and welded


fresh air package

Electronic expansion
valve Control box
(EKEXV) (EKEQ)

122
SKY AIR INTRO
Flexible control possibilities for air handling units

In order to maximise installation flexibility,


4 types of control systems are offered

INDOOR
UNITS
W control: Off the shelf control of air temperature (supply air Z control: Control of air temperature (return air temperature, room
temperature, return air temperature, room temperature) via any temperature) via Daikin control (no DDC controller needed)
DDC controller, easy to setup Y control: Control of refrigerant (Te/Tc) temperature via Daikin
X control: Precise control of air temperature (supply air temperature, control (no DDC controller needed)
return air temperature, room temperature) requiring

OUTDOOR
a preprogrammed DDC controller (for special applications)

UNITS
1.  W control (TS/TR/TROOM control): 2.  X control (TS/TR/TROOM control):
Air temperature control via DDC controller Precise air temperature control via DDC controller
Room temperature is controlled as a function of the air handling Room temperature is controlled as a function of the air handling

AIR CURTAINS
unit return air or supply air (customer selection). The DDC controller unit return air or supply air (customer selection). The DDC controller

BIDDLE
is translating the temperature difference between set point is translating the temperature difference between set point
and return air temperature (or supply air temperature or room and return air temperature (or supply air temperature or room
temperature) into a proportional 0-10V signal which is transferred temperature) into a reference voltage (0-10V) which is transferred
to the Daikin control box (EKEQFCBA). This voltage modulates the to the Daikin control box (EKEQFCBA). This reference voltage will be
capacity requirements of the outdoor unit. used as the main input value for the compressor
frequency control.
OR
OR OR
OR

VENTILATION
AHU
AHU AHU
AHU

TTEXT
EXT TTRR TTEXT
EXT TTRR
0-10V Daikin control
Control box box: 0-10V Daikin control
Control box box:
DDC
DDC
EKEQFCBA
EKEQFCBA + DDC
DDC
EKEQFCBA
EKEQFCBA +
TTOA TE T TTOA TE T
OA C T
TS
S
OA C T
TS
S
- -

TTROOM
ROOM TTROOM
ROOM

CONTROL
SYSTEMS
3.  Y control (TE/TC control): 4.  Z control (TR/TROOM control):
By fixed evaporating /condensing temperature Control your AHU just like a VRV indoor unit with 100% fresh air
A fixed target evaporating or condensing temperature can be set Allows the possibility to control the AHU just like a VRV indoor
by the customer. In this case, room temperature is only indirectly unit. Meaning temperature control will be focused on return air
controlled. A Daikin wired remote control (BRC1D52 or temperature from the room into the AHU. Requires BRC1D52 or
BRC1E53A/B/C - optional) have to be connected for initial set-up BRC1E53A/B/C for operation. This the only control that allows

& ACCESSORIES
but not required for operation. the combination of other indoor units to the AHU at the same time.

OPTIONS
AHU
AHU
TEXT TRR
BRC1D*
BRC1D* Control box
Control box TTEXT T
TR
EXT
BRC1E*
BRC1E* EKEQFCBA
EKEQFCBA + Control
Control box
box
TTOA TE TC BRC1D*
OA T
TS EKEQMCBA (VRVIV)
EKEQMCBA (VRV IV) +
S BRC1E* T TC
- EKEQDCB (ERQ)
EKEQDCB (ERQ) TTOA
OA E TS
-

TTROOM
& PLATFORMS

ROOM
OR
OR
TTROOM
ROOM
TOOLS

TS = Supply air temperature TR = Return air temperature TOA = Outdoor air temperature TROOM = Room air temperature
TC = Condensing temperature
TECHNICAL
DRAWINGS

TEXT = Extraction air temperature TE = Evaporating temperature

Option kit Features


Possibility W Off-the-shelf DDC controller that requires no pre-configuration
Possibility X EKEQFCBA Pre-configured DDC controller required
Possibility Y Using fixed evaporating temperature, no set point can be set using remote control
EKEQDCB Using Daikin infrared remote control BRC1D52 or BRC1E52A/B
Possibility Z
EKFQMCBA* Temperature control using return air temperature or room temperature (via remote sensor)
PREVIOUS

* EKEQMCB (for ’multi’ application)

123
ERQ - Air handling application

ERQ - for smaller capacities


(from 100 to 250 class)

A basic fresh air solution for pair application


›› Inverter controlled units
›› Heat pump
›› R-410A
›› Wide range of expansion valve kits available
›› Perfect for the Daikin Modular air handling unit
The “Daikin Fresh Air Package” provides a complete Plug & Play Solution including
AHU, ERQ or VRV Condensing Unit and all unit control (EKEQ, EKEX, DDC controller) ERQ-AW1
factory mounted and configured. The easiest solution with only one point of contact.

Ventilation ERQ 100AV1 125AV1 140AV1


Capacity range HP 4 5 6
Cooling capacity Nom. kW 11.2 14.0 15.5
Heating capacity Nom. kW 12.5 16.0 18.0
Power input Cooling Nom. kW 2.81 3.51 4.53
Heating Nom. kW 2.74 3.86 4.57
EER 3.99 3.42
COP 4.56 4.15 3.94
Dimensions Unit mm 1,345x900x320
Weight Unit kg 120
Fan-Air flow rate Cooling Nom. m³/min 106
Heating Nom. m³/min 102 105
Sound power level Cooling Nom. dBA 66 67 69
Sound pressure Cooling Nom. dBA 50 51 53
level Heating Nom. dBA 52 53 55
Operation range Cooling Min./Max. °CDB -5/46
Heating Min./Max. °CWB -20/15.5
On coil Heating Min. °CDB 10
temperature Cooling Max. °CDB 35
Refrigerant Type / GWP R-410A / 2.087,5
Charge kg/ TCO2Eq 4.0/8.4
Piping Liquid OD mm 9.52
connections Gas OD mm 15.9 19.1
Drain OD mm 26x3
Power supply Phase/Frequency/Voltage Hz/V 1N~/50/220-240
Current Maximum fuse amps (MFA) A 32.0

Ventilation ERQ 125AW1 200AW1 250AW1


Capacity range HP 5 8 10
Cooling capacity Nom. kW 14.0 22.4 28.0
Heating capacity Nom. kW 16.0 25.0 31.5
Power input Cooling Nom. kW 3.52 5.22 7.42
Heating Nom. kW 4.00 5.56 7.70
EER 3.98 4.29 3.77
COP 4.00 4.50 4.09
Dimensions Unit mm 1,680x635x765 1,680x930x765
Weight Unit kg 159 187 240
Fan-Air flow rate Cooling Nom. m³/min 95 171 185
Heating Nom. m³/min 95 171 185
Sound power level Nom. dBA 72 78
Sound pressure level Nom. dBA 54 57 58
Operation range Cooling Min./Max. °CDB -5/43
Heating Min./Max. °CWB -20/15
On coil Heating Min. °CDB 10
temperature Cooling Max. °CDB 35
Refrigerant Type / GWP R-410A / 2.087,5
Charge kg/ TCO2Eq 6.2/12.9 7.7/16.1 8.4/17.5
Piping Liquid OD mm 9.52
connections Gas OD mm 15.9 19.1 22.2
Power supply Phase/Frequency/Voltage Hz/V 3N~/50/400
Current Maximum fuse amps (MFA) A 16 25

124
SKY AIR INTRO
Overview of expansion valves and control boxes

Integration of ERQ in third party air handling units


a wide range of expansion valve kits and control boxes

INDOOR
UNITS
OUTDOOR
UNITS
Combination table
Control box Expansion valve kit
Mixed connection with
EKEQDCB EKEQFCBA EKEQMCBA EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500
VRV indoor units
Z control W,X,Y control Z control - - - - - - - - - -

AIR CURTAINS
ERQ100 P P - - P P P P - - - - -
1-phase ERQ125 P P - - P P P P P - - - -

BIDDLE
ERQ140 P P - - - P P P P - - - -
Not possible
ERQ125 P P - - P P P P P - - - -
3-phase ERQ200 P P - - - - P P P P P - -
ERQ250 P P - - - - - P P P P - -
VRV III - - n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 Mandatory
VRV IV H/P / Possible (not
VRV IV W-series - P (1 -> 3) n2 n2 n2 n2 n2 n2 n2 n2 n2 n2 n2 mandatory)
VRV IV S-series
VRV IV H/R - - n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 n1 Mandatory

VENTILATION
VRV IV i-series
• P (pair application): combination depends on the capacity of the air handling unit
• n1 (multi application) - Combination of AHUs and VRV DX indoors (mandatory). To determine the exact quantity please refer to the engineering data book.
• n2 (multi application) - Combination of AHUs and VRV DX indoors (not mandatory). To determine the exact quantity please refer to the engineering data book.data book
• Control box EKEQFA can be connected to some types of VRV IV outdoor units (with a maximum of 3 boxes per unit). Do not combine EKEQFA control boxes with VRV DX indoor units, RA indoor units or hydroboxes

Capacity table
Cooling Heating
Allowed heat exchanger capacity (kW) Allowed heat exchanger capacity (kW)

CONTROL
SYSTEMS
EKEXV Class EKEXV Class
Minimum Standard Maximum Minimum Standard Maximum
50 5.0 5.6 6.2 50 5.6 6.3 7.0
63 6.3 7.1 7.8 63 7.1 8.0 8.8
80 7.9 9.0 9.9 80 8.9 10.0 11.1
100 10.0 11.2 12.3 100 11.2 12.5 13.8
125 12.4 14.0 15.4 125 13.9 16.0 17.3
140 15.5 16.0 17.6 140 17.4 18.0 19.8
200 17.7 22.4 24.6 200 19.9 25.0 27.7

& ACCESSORIES
250 24.7 28.0 30.8 250 27.8 31.5 34.7

OPTIONS
400 35.4 45.0 49.5 400 39.8 50.0 55.0
500 49.6 56.0 61.6 500 55.1 63.0 69.3
Saturated evaporating temperature: 6°C, SH: 5K Saturated condensing temperature: 46°C, SC: 3K
Air temperature: 27°C DB / 19°C WB Air temperature: 20°C DB

EKEXV - Expansion valve kit for air handling applications


Ventilation EKEXV 50 63 80 100 125 140 200 250 400 500
& PLATFORMS

Dimensions Unit mm 401x215x78


Weight Unit kg 2.9
TOOLS

Sound pressure level Nom. dBA 45


Operation range On coil Heating Min. °CDB 10 (1)
temperature Cooling Max. °CDB 35 (2)
Refrigerant Type / GWP R-410A / 2.087,5
Piping connections Liquid OD mm 6.35 9.52 12.7 15.9

(1) The temperature of the air entering the coil in heating mode can be reduced to -5°CDB. Contact your local dealer for more information. (2) 45% Relative humidity.
TECHNICAL
DRAWINGS

EKEQ - Control box for air handling applications


Ventilation EKEQ FCBA DCB MCBA
Application See note Pair Multi
Outdoor unit ERQ / VRV ERQ VRV
Dimensions Unit mm 132x400x200
Weight Unit kg 3.9 3.6
Power supply Phase/Frequency/Voltage Hz/V 1~/50/230

The combination of EKEQFCBA and ERQ is in pair application. The EKEQFCBA can be connected to some type of VRV IV outdoor units with a maximum of 3 control boxes. The combination with DX indoor units,
PREVIOUS

hydroboxes, RA outdoor units, ... is not allowed. Refer to the combination table drawing of the outdoor unit for details.

125
Market leading
controls
Intuitive & user-friendly interface
Cross pillar integration
Cloud control
Smart energy management
Integration of Daikin and third party products

Online Controller
›› Simple control from your smartphone
›› Control your device at anytime from anywhere
›› For single shop control
›› 3rd party products and services integration via IFTTT
›› IFTTT is a solution that connects compatible 3rd party products
and services (smart meters, lights, thermostats, ...), so they work
best for you.
››
  more information on page 132

DCC601A51
Advanced centralised controller
with Cloud connection
›› Simply control your entire building centrally
›› Total solution concept (integration of Split, Sky Air, VRV, ventilation,
air curtains and hot water)
›› Stylish optional screen fits any interior
›› Cloud connection offers additional services
such as online control, energy monitoring, comparison of energy
consumption of multiple sites
›› Connect up to 32 indoor units

  more information on page „Advanced centralised


controller with Cloud connection“ on page 140

Find out more on www.daikineurope.com

126
SKY AIR INTRO
INDOOR
UNITS
Control

OUTDOOR
UNITS
Systems

AIR CURTAINS
BIDDLE
Control Systems 128
Requirements tables per application  128
Online controller 130 NEW
Individual control systems  132 NEW
Wired / infrared remote controls  136

VENTILATION
Centralised control systems 138
Centralised remote control /
Unified ON/OFF control / Schedule timer  138
Adapter DTA113B51  139
 139
Advanced centralised controller
with Cloud connection 140

CONTROL
SYSTEMS
Mini building management system 142
142

Standard protocol interfaces 146


Modbus interface 146
RTD-20 Retail Economiser 146

& ACCESSORIES
DIII-net Modbus interface 150

OPTIONS
KNX Interface 151

Wireless room temperature sensor 152


Wired room temperature sensor  152
Other integration devices  153

Options & Accessories  154


& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS

Find out more about our control systems online:


www.daikineurope.com/commercial/needs/controls
PREVIOUS

127
Requirements tables per application

Requirement tables per application


Daikin offers various control solution adapted to the requirements of even the most
demanding commercial application.
›› Basic control solutions for those customers with few ›› Advanced control solutions for those customers
requirements and limited budget that expect Daikin to deliver a mini BMS solution,
›› Integrating control solutions for those customers including advance energy management
that would like to integrate Daikin units into their
existing BMS system

Shop Unit control Integrating control Advanced control


BRC1H51
RTD-20 RTD-Net KLIC-DI EKMBDXA DCC601A51 DCM601A51
BRC1E53A/B/C
1 remote 1 gateway for 1 gateway for 1 1 gateway for 1 1 gateway for 1 unit for 32 1 iTM for 64
controller for 1 indoor unit indoor unit indoor unit max. 64 indoor indoor unit(s) indoor unit(s)
1 indoor unit (group) (group) unit(s) (groups) (groups) (1)
(group) & 10 outdoors
Automatic control of A/C       
Limited control possibilities for shop staff       
Create zones within the shop   
Interlock with eg. Alarm, PIR sensor   
Integrate Daikin units into existing BMS via Modbus  
Integrate Daikin units into existing BMS via KNX 
Integrate Daikin units into existing BMS via HTTP 
Monitor energy consumption (2) 
Advanced energy management (2) 
Allows free cooling  
Integrate Daikin products cross pillars
into Daikin BMS 
Integrate third party products into Daikin BMS  
Online control (2) 
Manage multiple sites (2)
(1) : 7 iTM plus adapters (DCM601A52) can be added to have 512 indoor groups and 80 outdoor (systems) (2) Via cloud control

Hotel Unit control Integrating control Advanced control


BRC1H51
RTD-Net KLIC-DI DCS601C51 DCM601A51
BRC2/3E52C
1 remote controller
1 gateway for 1 1 gateway for 1 1 iTC for 64 indoor 1 iTM for 64 indoor
for 1 indoor unit
indoor unit (group) indoor unit unit(s) (groups) unit(s) (groups) (1)
(group)

Hotel guest can control & monitor basic functionalities from his room     
Limited control possibilities for hotel guests     
Interlock with window contact (2) 
Interlock with key-card (2) 
Integrate Daikin units into existing BMS via Modbus 
Integrate Daikin units into existing BMS via KNX 
Integrate Daikin units into existing BMS via HTTP 
Monitor energy consumption 
Advanced energy management 
Integrate Daikin products cross pillars into Daikin BMS 
Integrate third party products into Daikin BMS 
Online control 
(1) : 7 iTM plus adapters (DCM601A52) can be added to have 512 indoor groups and 80 outdoor (systems) (2) Via BRP7A51 adapter

128
SKY AIR INTRO
Requirements tables per application

INDOOR
UNITS
Office Unit control Integrating control Advanced control
BRC1H51 DMS502A51 / DCS302C51 /
EKMBDXA DMS504B51 DCS601C51 DCM601A51
BRC1E53A/B/C DAM412B51 DST301B51

OUTDOOR
UNITS
1 remote 1 gateway for 1 gateway for 1 R/C for max.
1 gateway for 1 iTC for 64 1 iTM for 64
controller for max. 64 indoor 128 indoor 64 groups, 128
64 indoor unit(s) indoor unit(s) indoor unit(s)
1 indoor unit unit(s) (groups) unit(s) (groups), indoor units, 10
(groups) (groups) (groups) (1)
(group) & 10 outdoors 20 outdoors (2) outdoors

Automatic control of A/C      (3)  


Centralised control for management      
      

AIR CURTAINS
Local control for office workers

BIDDLE
Limited control possibilities for office workers   
Integrate Daikin units into existing BMS via Modbus 
Integrate Daikin units into existing BMS via HTTP 
Integrate Daikin units into existing BMS via LonTalk 

VENTILATION
Integrate Daikin units into existing BMS via BACnet

Energy consumption read out 


Monitor energy consumption 
Advanced energy management 
Integrate Daikin products cross pillars into Daikin
BMS 

CONTROL
SYSTEMS
Integrate third party products into Daikin BMS

Online control 
(1) : 7 iTM plus adapters (DCM601A52) can be added to have 512 indoor groups and 80 outdoor (systems)
(2) : extension needed to go to 256 indoor unit(s) (groups), 40 outdoors
(3) : ON/OFF only

& ACCESSORIES
OPTIONS
Infrastructure cooling Unit Integrating Advanced
BRC1H51 RTD-10 DCM601A51
BRC1E53A/B/C
1 remote 1 gateway for 1 iTM for 64
controller for 1 indoor unit indoor unit(s)
1 indoor unit (group) (groups) (1)
& PLATFORMS

(group) (2) Up to 8
gateways
TOOLS

can be linked
together
Automatic control of A/C
  
Back-up operation
  
Duty rotation
  
TECHNICAL
DRAWINGS

Limited control possibilities in the infrastructure cooling room


  
If room temperature above max., then show alarm & start standby
unit.   
If an error occurs, an alarm will be shown.
  
(1) : 7 iTM plus adapters (DCM601A52) can be added to have 512 indoor groups and 80 outdoor (systems) (2) Infrastructure cooling functions only
PREVIOUS

compatible with indoor units connected to Seasonal Smart outdoor units.

129
Individual control systems

Online controller
BRP069A41/42/43/45/61/62 /81

Always in control,
no matter where you are

The Daikin Online Controller application can control


and monitor the status of your heating system or up
to 50 split air conditioning units and allows you to:
Monitor:
›› The status of your air conditioner or heating system
›› Consult energy consumption graphs
Control:
›› The operation mode, set temperature, fan speed
and powerful mode, air direction and filtering
(streamer) function
›› Remotely control your system and domestic hot
water
›› Zone control: control multiple units at once
(Split and Daikin Altherma integrated bi-zone only)
Schedule:
›› Schedule the set temperature and operation mode
with up to 6 actions per day for 7 days
›› Enable holiday mode
›› View in an intuitive mode
›› 3rd party products & services integration via IFTTT
›› Demand control/power power limitation (Split only)

App with intuitive lay-out

Control Schedule Monitor Identify

Control operation Schedule the set Monitor your energy Identify the rooms
mode, temperature, air temperature, operation consumption, set holiday in your house
purification, fan speed mode and fan speed schedule
& direction

130
SKY AIR INTRO
Individual control systems

INDOOR
UNITS
Connectable units

BRP069A41 BRP069A42 BRP069A43 BRP069A45 BRP069A61/62 BRP069A81


›› FTXG-LW/S ›› FTXZ-N ›› CTXS15-35K ›› FTX20-25-35KV Daikin Altherma Ceiling mounted
›› FTXJ-MW/S * ›› FTXS35-42-50K ›› FTXS20-25K ›› FTX50-60KV ground source ›› FCAHG-G

OUTDOOR
UNITS
›› FTXS60-71G ›› FTX20-25-35J3 ›› ATX-KV heat pump ›› FCAG-A
›› FTX50-60-71GV ›› FTXL-JV ›› C/FTXM-M ›› EGSQH-A9W ›› FFA-A
›› FTXLS-K3 ›› ATXS20-25K ›› FTXP-KV Daikin Altherma Concealed ceiling
›› FVXG-K ›› ATX-J3 ›› ATXM-M hybrid heat pump ›› FDXM-F3
›› FVXS-F ›› ATXL-JV ›› ATXP-KV ›› EHYHBH(X)-AV3(2) ›› FBA-A
›› FLXS-B(9) Daikin Altherma ›› FDA-A
›› ATXS35-50K low temperature ›› ADEQ-C

AIR CURTAINS
split Wall mounted

BIDDLE
›› EHBH(X)-CB ›› FAA-A
›› EHVH(X)-CB Ceiling suspended
Daikin Altherma ›› FHA-A
low temperature ›› FUA-A
* controller included with the unit
monobloc Floor standing
›› EBLQ-CV3 ›› FVA-A
›› EDLQ-CV3 ›› FNA-A

VENTILATION
CONTROL
SYSTEMS
IFTTT: make your work flow
IFTTT is a solution that connects compatible 3rd party products
and services (smart meters, lights, thermostats, ...), so they work
best for you.
Within IFTTT, 2 operation set-ups can be made:
›› DO: it simply executes an action (e.g.: on/off )
›› IFTTT stands for If This Then That and allows you to automate

& ACCESSORIES
actions (Then That) depending on certain triggers (If This)

OPTIONS
& PLATFORMS

Example
TOOLS

IF you exit an area, THEN turn off the heating.


The trigger is location, which is determined by your smartphone. If you
leave an area, such as your house for example, your heating will turn
off automatically.

IF there is an error signal on the unit, THEN a text message is sent


ERROR
TECHNICAL
DRAWINGS

(to the installer/user/...)


PREVIOUS

131
Individual control systems

Wired remote controller with premium design


BRC1H51 W/S/B

User-friendly
wired remote controller
with premium design

Glossy white
BRC1H51W

Experience a new way of air conditioning


control & commissioning
A complete redesigned controller
focussed to enhanced
user experience

• Sleek and elegant design


• Intuitive touch button control
• User-friendly symbol driven interface

Silver metallic Black matte


• 3 colors to match any interior design
BRC1H51S BRC1H51B
• Compact, flat back for easy wall installation
* Info on this page is preliminary

132
SKY AIR INTRO
Individual control systems

INDOOR
UNITS
Advanced settings can be easily done
via your smartphone

OUTDOOR
UNITS
Low energy

AIR CURTAINS
BIDDLE
• BLE (Bluetooth Low Energy) communication
• Intuitive setting of schedules and advanced functions for end users / property managers
• Easy commissioning for installers

VENTILATION
• Time saving copy possibility of settings between different controllers
(e.g. in hotel applications)

CONTROL
SYSTEMS
Schedule Advanced Installer settings Field settings
user settings

& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

133
134
SKY AIR INTRO
Individual control systems

BRC1H51W / BRC1H51S / BRC1H51K

Premium touch button remote control


for Sky Air and VRV

INDOOR
A series of energy saving functions that Other functions

UNITS
can be individually selected
›› Up to 3 independent schedules can be set,
›› Demand control: decreases the power consumption so the user can easily change the schedule himself
to 70 or 40 % when other large applicances need to throughout the year (e.g. Summer, winter, mid-season)
be switched on (1) ›› Possibility to individually restrict menu functions
›› Temperature range limit Easy to use: all main functions directly accessible
BRC1H51W ›› Setback function ›› Choice of display between symbol or text

OUTDOOR
UNITS
›› Presence & floor sensor connection ›› Easy setup: clear graphical user interface for
(available on round flow and fully flat cassette) advanced menu settings
›› kWh indication (2) ›› Remote control save mode : screen turns off when
›› Set temperature auto reset no person is changing mode or adjusting settings
›› Off timer ›› Selection of quiet mode function for the outdoor
unit (1)
Temperature range limit avoids excessive ›› Real time clock with auto update to daylight

AIR CURTAINS
heating or cooling saving time

BIDDLE
BRC1H51S
›› Built-in backup power: when a power failure occurs
Save energy by constraining the lower temperature all settings remain stored up to 48 hours
limit in cooling and upper temperature limit in
heating mode.
note : Also available in auto cooling/heating change over mode.

kWh indication keeps track of

VENTILATION
your consumption (2)
BRC1H51K
The kWh indication shows an indicative electricity
consumption of the last day/month/year.

Cost-effective solution for infrastructure cooling applications


> Only in combination with RZAG* / RZQG*
> Duty rotation

CONTROL
SYSTEMS
After a certain period of time, the operating unit will go into standby and the standby unit will take over, increasing lifetime of the system
Rotation interval can be set from 6h, 12h, 24h, 72h, 96h, weekly

> Back-up operation: if one unit fails, the other unit will automatically start

(1) Only available on RZAG*, RZASG*, RZQG*, RZQSG*

& ACCESSORIES
(2) For Sky Air FBA, FCAG and FCAHG pair combinations only

Hotel application functions OPTIONS

›› Energy saving thanks key card, window contact ›› Flexible setback function ensures room
integration and set point limitation (BRP7A51) temperature remains within comfortable limits to
ensure guest comfort
& PLATFORMS
TOOLS

Key card and


window contact
P1 P2
integration Adaptator Key card (field supply)
(BRP7A51)
TECHNICAL
DRAWINGS

Window contact
(field supply)

BRC1H51W

Advanced settings/read out can be easily done via your smartphone


PREVIOUS

135
Individual control systems

BRC1E53A/B/C

User friendly remote control for Sky Air and VRV


A series of energy saving functions that
can be individually selected Other functions

›› Demand control (1) ›› Up to 3 independent schedules


›› Temperature range limit ›› Possibility to individually restrict menu functions
›› Setback function ›› Choice of display between symbol or text
›› Presence & floor sensor connection ›› Real time clock with auto update to daylight
(available on round flow and fully flat cassette) saving time
Graphical display of indicative
›› kWh indication (2) ›› Built-in backup power
electricity consumption
›› Set temperature auto reset ›› Supports multiple languages:
(Function available in
›› Off timer BRC1E53A: English, German, French, Dutch, Spanish,
combination with FBA-A, FCAG
Italian, Portugese
and FCAHG)
Cost-effective solution for infrastructure BRC1E53B: English, Czech, Croation, Hungarian,
cooling applications Romanian, Slovenian, Bulgarian
> Only in combination with RZAG* / RZQG* BRC1E53C: English, Greek, Russian, Turkish, Polish,
Slovak, Albanian
(1) Only available on RZAG*, RZASG*, RZQG*, RZQSG*
(2) For Sky Air FBA, FCAG and FCAHG pair combinations only

BRC2E52A / BRC3E52A

Simplified wired remote control developed for hotel applications


›› Symbol driven interface for intuitive control ›› Flat backpanel for easy installation
›› Functions restricted to basic customer needs ›› Easy commissioning: intuitive interface
›› Energy saving thanks key card, window contact for advanced menu settings
integration and set point limitation (BRP7A51) ›› 2 versions available:
›› Flexible setback function ensures room • BRC3E52C: temperature, fan speed, ON/OFF
temperature remains within comfortable limits to • BRC2E52C: temperature, mode, fan speed,
ensure guest comfort ON/OFF
BRC2E52C
With operation mode selector

BRC1D52

Wired remote control


›› Schedule timer: Five day actions can be set ›› Operating mode
›› Home leave (frost protection): during absence, the ›› Heat Recovery Ventilation (HRV) in operation
indoor temperature can be maintained at a certain ›› Cool / heat changeover control
level. This function can also switch the unit ON/OFF ›› Centralised control indication
›› User friendly HRV function, thanks to ›› Group control indication
the introduction of a button for ventilation mode ›› Set temperature
and fan speed ›› Air flow direction
›› Immediate display of fault location and condition ›› Programmed time
›› Reduction of maintenance time and costs ›› Inspection test / operation
›› Fan speed
BRC1D52 ›› Clean air filter
›› Defrost / hot start
›› Malfunction

ARC4*/BRC4*/BRC7*

Infrared remote control


Operation buttons: ON / OFF, timer mode start / stop, 1. Not applicable for FXDQ,
timer mode on  / off, programme time, temperature FXSQ, FXNQ, FBDQ, FDXM, FBA
setting, air flow direction (1), operating mode, fan 2. For FX** units only
speed control, filter sign reset (2), inspection (2)/ test 3. For all features of the remote
indication (2)  control, refer to the operation
Display: Operating mode, battery change, set manual
temperature, air flow direction (1), programmed time,
fan speed, inspection / test operation (2)
ARC466A1 BRC4*/BRC7*

136
SKY AIR INTRO
Individual control systems

ARCWLA / ARCWB

Siesta individual control systems


Overview controllers for Siesta Sky Air

INDOOR
UNITS
Siesta Sky Air indoor units Controllers
• Standard infrared remote control in box of indoor unit ARCWLA
AHQ-C ceiling suspended • Wired remote control ARCWB
• Optional group controller R04084124324
• Standard wired remote control (ARCWB) in box of indoor unit
ABQ-C concealed ceiling
• Optional group controller R04084124324

OUTDOOR
UNITS
AIR CURTAINS
BIDDLE
Overview of features

Feature ARCWB

AHQ-C and ACQ-D / Standard for ABQ-C

VENTILATION
1 ON/OFF switch -
Default range 16-30°C -
2 Temperature setting Optional range 20-30°C •
Switch between °C and °F -
ARCWB 3 Room temperature sensor on remote control -
4 Cool / Fan dry / Heat / Auto -
5 Sleep mode -
6 Fan Speed selection -

CONTROL
SYSTEMS
7 Delay timer ••
8 7-days programmable timer -
9 Real time clock display -
ON/OFF swing mode -
Change swing option
10 Air swing selection
(draft/soil prevention or -
standard)

& ACCESSORIES
11 LCD display without backlight -

OPTIONS
12 Key lock -
13 Error code indication -
IR receiver to enable compatibility with infrared remote control
14 -
(disabled when lock function is activated)
15 Last state memory from indoor PCB -
16 Silent mode •
17 Turbo mode •
& PLATFORMS

18 Compressor test model (compressor force ON) -


19 Daikin inverter error code -
TOOLS

20 UART communication port (for Daikin protocol) -


21 Backup battery -

Specifications - Standard
›› Dimensions (length x width x height) ARCWB: • By dipswitch selection
TECHNICAL
DRAWINGS

0.15 m x 0.21 m x 0.04 m. • • 1, 2 & 4 hours delay


›› ARCWB comes standard with a 10 metre cable,
which can be extended to maximum cable length
of 15 metres. ARCWB can only control one indoor
unit at a time; group control is only possible when
using option R04084124324.
PREVIOUS

137
Centralised control systems

Centralised control of the Sky Air and VRV system can be achieved via 3 user friendly compact remote
controllers. These controls may be used independently or in combination with 1 group = several (up to 16)
indoor units in combination and 1 zone = several groups in combination.
A centralised remote control is ideal for use in tenanted commercial buildings subject to random occupation,
enabling indoor units to be classified in groups per tenant (zoning).
The schedule timer programmes the schedule and operation conditions for each tenant and the control can
easily be reset according to varying requirements.

DCS302C51

Centralised remote control


Providing individual control of 64 groups (zones) of indoor units.
›› a maximum of 64 groups (128 indoor units, max. 10 outdoor units)
can be controlled
›› a maximum of 128 groups (128 indoor units, max. 10 outdoor units)
can be controlled via 2 centralised remote controls in separate
locations
›› zone control
›› group control
›› malfunction code display
›› maximum wiring length of 1,000m (total: 2,000m)
›› air flow direction and air flow rate of HRV can be controlled
›› expanded timer function

DST301B51

Schedule timer
Enabling 64 groups to be programmed.

›› a maximum of 128 indoor units can be controlled


›› 8 types of weekly schedule
›› a maximum of 48 hours back up power supply
›› a maximum wiring length of 1,000m (total: 2,000m)

DCS301B51

Unified ON/OFF control


Providing simultaneous and individual control of 16 groups
of indoor units.

›› a maximum of 16 groups (128 indoor units) can be controlled


›› 2 remote controls in separate locations can be used
›› operating status indication (normal operation, alarm)
›› centralised control indication
›› maximum wiring length of 1,000m (total: 2,000m)

138
SKY AIR INTRO
Centralised control systems

DTA113B51

Basic solution for control of Sky Air and VRV

INDOOR
UNITS
adapter - DTA113B51
›› Rotation function
›› Backup operation function.

OUTDOOR
BRC1E53A/B/C

UNITS
Up to 4 units / 1 adapter

AIR CURTAINS
BIDDLE
DCS601C51

Detailed & easy monitoring and operation of VRV systems (max. 64 indoor units groups).

VENTILATION
third party controller (domotics, BMS, etc.) via http interface Fire alarm

Ethernet
Forced OFF contact input

DIII-NET

CONTROL
SYSTEMS
Indoor units HRV

DCS601C51

& ACCESSORIES
OPTIONS
Languages Control Monitoring Open interface
›› English ›› Individual control ›› Visualisation via Graphical ›› Communication to any third
›› French (set point, start/stop, User Interface (GUI) party controller (domotics,
›› German fan speed) ›› Icon colour display change BMS, etc.) is possible via
›› Italian (max. 64 groups/indoor units) function open interface (http option
›› Spanish ›› Set back shedule ›› Indoor units operation mode DCS007A51)
›› Dutch ›› Enhanced scheduling func- ›› Indication filter replacement
& PLATFORMS

›› Portuguese tion ›› Multi PC Connectable to


TOOLS

(8 schedules, 17 patterns) ›› VRV


System layout ›› Flexible grouping in zones Cost performance ›› HRV
›› Up to 64 indoor units can be ›› Yearly schedule ›› Free cooling function ›› Sky Air
controlled ›› Fire emergency stop control ›› Labour saving ›› Split (via interface adapter)
›› Touch panel (full colour LCD ›› Interlocking control ›› Easy installation
via icon display) ›› Increased HRV monitoring ›› Compact design: limited
and control function installation space
TECHNICAL
DRAWINGS

›› Automatic cooling / heating ›› Overall energy saving


change-over
›› Heating optimization
›› Temperature limit
›› Password security: 3 levels
(general, administration
& service)
›› Quick selection and full
PREVIOUS

control
›› Simple navigation
139
NEW   Centralised control systems

Table
t

DCC601A51

Advanced • Intuitive and user-friendly interface

centralised • Flexible concept for stand alone


and multi site applications
• Total solution thanks to

controller integration of 3rd party equipment


• Monitor & control your small
commercial building, no matter
with Cloud connection where you are
2 solutions:
Local solution Cloud solution
›› Offline centralised control ›› Flexible online control from any device (Laptop,
›› Stylish optional screen fits any interior tablet...)
›› Monitor & control one or multiple sites
›› Benchmark the energy consumption of different
installations (1)
›› Energy consumption follow-up to comply
with local regulations
System layout

Local solution Online control from any device

Alarm

Window
contact

Daikin supplied screen


(optional) (for local control)
Pulse input
Z380C-1A023A
or
Digital input

Local network

Daikin supplied router


(optional) 4G-N12

Table
t

DCC601A51
WAGO power CPU module I/O module
supply

Split, , , …
VAM, ventilation,
air curtains
(1) For VRV

140
SKY AIR INTRO
Centralised control systems  NEW

Total solution From one to ∞ sites

INDOOR
UNITS
›› Total solution thanks to a large integration of
Daikin products and 3rd party equipment LOCAL
CONTROL

›› Connect a wide range of units (Split, Sky Air, VRV,


Ventilation, Biddle air curtains)
›› Simply control your entire building centrally
›› Increased customer shopping experience by bet-
ter management of your shop comfort level

OUTDOOR
UNITS
Daikin Cloud Services

›› Control your building no matter where you are


Customer Installer/
›› Monitor and control multiple sites technical manager
›› Installer or technical manager can remotely login
to the cloud for first troubleshooting
›› Benchmark the energy consumption

AIR CURTAINS
of different installations (1)

BIDDLE
›› Manage & track your energy use

User friendly touch control

›› Stylish Daikin supplied optional screen


for local control fits any interior Intuitive control from the cloud
›› Intuitive and user-friendly interface

VENTILATION
›› Full solution with simple control
›› Easy commissioning

Flexible

›› Inputs via digital and pulse input for 3rd party


equipment such as kWh meters, emergency
input, window contact, … Easy follow up of energy consumption

CONTROL
SYSTEMS
›› Modular concept allows your cloud to grow
with your business
›› Control up to 32 indoor unit (groups)

Pulse input

& ACCESSORIES
OPTIONS
Digital input

Functions overview
Indoor uit
Local solution Cloud solution
Languages EN, DE, FR, NL, ES, IT, EL, PT,
& PLATFORMS

Depends on local device RU, TR, DA, SV, NO, FI, CS,
HR, HU, PL, RO, SL, BG, SK
TOOLS

System layout N° of connectable indoor units 32 32


Multiple sites control
Monitoring & Basic control functions (ON/OFF, mode, filter sign, setpoint, fan
control speed, ventilation mode, room temperature, …)
Remote control prohibition
All devices ON/OFF
Zone control
Group control
TECHNICAL
DRAWINGS

Weekly schedule
Yearly schedule
Interlock control
Set point limitation
Visualisation of energy use per operation mode
Connectable to DX split, Sky Air, VRV
VAM, VKM ventilation
PREVIOUS

Air curtains

For available Daikin Cloud Service options refer to the option list
141
Centralised control systems

Mini BMS
with full integration
across all product pillars
DCM601A51

• Price competitive mini BMS


• Cross-pillar integration of Daikin products
• Integration of third party equipment

NEW
Download the WAGO
selection tool from
my.daikin.eu
›› Easy selection of WAGO materials
›› Material list creation
›› Time saving
- Includes wiring schemes
- Contains commissioning/preset data for iTM

Check on

https://www.youtube.com/
DaikinEurope

142
SKY AIR INTRO
Centralised control systems

System overview

INDOOR
UNITS
Web Access

OUTDOOR
UNITS
CLOUD

Internet
Extranet
LAN
3G

AIR CURTAINS
HTTP interface

BIDDLE
Integration of third Full control of Daikin
party equiqment HVAC-R portfolio

Max. 7
DCM601A51 ITM plus adaptor line adapters

VENTILATION
Fire alarm Di/Pi line
Max. 200m
DCM601A52

Di/Pi port

kWh meter
Direct plug & play connection!

CONTROL
SYSTEMS
Split

Conveni-pack indoor
BACnet/IP

units
Chillers and AHU
Fan coil units

protocol WAGO indoor units,


interface air curtain,
Analog/digital/pulse objects hydrobox,

& ACCESSORIES
I/O module

air handling units

OPTIONS
Lighting Fan
I/O module

Pump Sensor
& PLATFORMS
TOOLS

Multi state objects

Elevator Air handling unit Alarm


TECHNICAL
DRAWINGS

NEW

DALI Lighting

Protocol

Sensor
PREVIOUS

143
Centralised control systems

User friendliness

›› Intuitive user interface
›› Visual lay out view and direct access to indoor unit
main funtions
›› All functions direct accessible via touch screen
or via web interface

Smart energy management Split

›› Monitoring if energy use is according to plan


›› Helps to detect origins of energy waste
›› Powerful schedules guarantee correct operation
throughout the year
›› Save energy by interlocking A/C operation with Plug & play
other equipment such as heating

Flexibility

›› Cross-pillar integration (heating, air conditioning,


applied systems, refrigeration, air handling units)
›› BACnet protocol for 3rd party products integration Fan coils
›› I/O for integration of equipment such as lights,
pumps… on WAGO modules
›› Modular concept for small to large applications
Chillers and AHU
›› Control up to 512 indoor unit groups via one ITM
and combine multiple ITM via web interface

Easy servicing and commissioning Conveni-pack indoor units

›› Remote refrigerant containment check reducing


on site visit
›› Simplified troubleshooting
›› Save time on commissioning
thanks to the pre-commissioning tool
›› Auto registration of indoor units DALI
Lighting

Protocol

Sensor

BACnet/IP
protocol
Lighting Air handling
unit

Flexibility in size Pump Elevator

64 up to 512 groups
Fan Alarm

Sensor

Lighting Fan

WAGO I/O

Pump Sensor

144
SKY AIR INTRO
Centralised control systems

Functions overview

INDOOR
UNITS
Languages Management WAGO Interface Open http interface
›› English ›› Web access ›› Modular integration of ›› Communication to any third
›› French ›› Power Proportional 3rd party equipment party controller (domotics,
›› German Distribution (option) - WAGO coupler (interface BMS, etc.) is possible via http
›› Italian ›› Operational history between WAGO and iTM) open interface (http option
›› Spanish (malfunctions, …) - Di module DCM007A51)
›› Dutch ›› Smart energy management - Do module
›› Portuguese - monitor if energy use - Ai module

OUTDOOR
UNITS
is according to plan - Ao module
- detect origins of - Thermistor module
energy waste - Pi module
›› Setback function
›› Sliding temperature

NEW

AIR CURTAINS
System layout Control DALI integration Connectable to

BIDDLE
›› Up to 512 unit groups can be ›› Individual control ›› Control and monitor the lights - DX Split, Sky Air, VRV
controlled (512 groups) ›› Easier facility management: - Chillers
(ITM + 7 iTM Plus adapters) ›› Schedule setting (Weekly receive error signal when (via MT3-EKMBACIP
schedule, yearly calender, light or light controller has controller)
seasonal schedule) a malfunction - Daikin AHU
›› Interlock control ›› Flexible approach and less - Fan coils
›› Setpoint limitation wiring needed, compared - Daikin Altherma Flex type

VENTILATION
›› Temperature limit to classic light scheme - LT and HT hydroboxes
›› Easier to make groups and - Biddle Air curtains
control scenes - WAGO I/O
›› Connection between - BACnet/IP protocol
intelligent Touch Manager and
DALI through WAGO BACnet
IP interface

CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

145
Standard protocol interfaces

Modbus Interface RTD-20 retail economiser


RTD Control zones in shop applications

RTD-NET Zoning
›› Modbus interface for monitoring and control
Stockroom
of Sky Air, VRV, VAM and VKM
Reduce energy costs for
non-comfort areas by
RTD-10 setting a different, wider
›› Advanced integration into BMS of Sky Air, VRV, temperature band
VAM and VKM through either:
- Modbus
- Voltage (0-10V)
- Resistance
›› Duty/standby function for server rooms
Retail zone
Timer sets pre-trade,
trade and post-trade Kitchen
RTD-20
conditions Individual control by the staff
›› Retail economisor
›› Advanced control of Sky Air, VRV, VAM/VKM
Changing rooms
and air curtains
›› Clone or independent zone control Custom settings to provide
›› Increased comfort with integration of CO2 sensor a warmer zone for changing
for fresh air volume control rooms for maximum customer
›› Save on running costs via comfort
- pre/post and trade mode
- set point limitation
- overall shut down
- PIR sensor for adaptive deadband Control options benefits
Optimize the operation of the air conditioning
without compromising occupant comfort
RTD-HO
›› Modbus interface for monitoring and control of
Sky Air, VRV, VAM and VKM Without RTD-20 With RTD-20
›› Intelligent hotel room controller ›› Pre-trade: ›› Pre-trade:
• AC either on (timer) or off • De-stratification on start-up
• whole store heated or cooled • Heat/Cool protection enabled
›› Trading: • AC only comes on if internal
• achieving set-point temp above 26°C or below 19°C
• staff could access controllers • achieving midpoint of 19-23°C
• heat cool clash can occur • controllers locked
• door curtain not interlocked • heat cool clash prevented
• always trying to achieve set-point • door curtain interlocked
›› Post-Trade: • learns store patterns & heats/
• either on or off cools “enough” to reach set-point
›› Post-Trade:
• Heat/cool protection enabled
• Trade extension function

Integrate all essential store operations in one control


Optimize the operation of the air conditioning without compromising occupant
comfort.
Accumulated kWh
70000
Up to 35%
60000
saving!
50000
40000
30000
20000   Occupied year 1
10000   Occupied year 2
0
0 500 1000 1500 2000 2500 Accumulated heating + cooling degree days

146
SKY AIR INTRO
Overview functions

Overview functions

INDOOR
UNITS
OUTDOOR
Main functions RTD-NET RTD-10 RTD-20 RTD-HO

UNITS
Dimensions HxWxD mm 100 x100 x 22
Key card + window contact 
Set back function 
Prohibit or restrict remote control functions (setpoint limitation, ...)   ** 
Modbus (RS485)    
Group control    
0 - 10 V control  

AIR CURTAINS
Resistance control  

BIDDLE
IT application 
Heating interlock  
Output signal (on/defrost, error)  **** 
Retail application 
Partitioned room control 
Air curtain *** *** 
(1): By combining RTD-RA devices

VENTILATION
Control functions RTD-NET RTD-10 RTD-20 RTD-HO
On/Off M M,V,R M M*
Set point M M,V,R M M*
Mode M M,V,R M M*
fan M M,V,R M M*
Louver M M,V,R M M*
HRV Damper control M M,V,R M

CONTROL
SYSTEMS
Prohibit/Restrict functions M M,V,R M M*
Forced thermo off

Monitoring functions RTD-NET RTD-10 RTD-20 RTD-HO


On/Off M M M M
Set point M M M M

& ACCESSORIES
Mode M M M M

OPTIONS
fan M M M M
Louver M M M M
RC temperature M M M M
RC mode M M M M
nbr units M M M M
Fault M M M M
Fault code M M M M
Return air temperature (Average /Min/Max) M M M M
& PLATFORMS

Filter alarm M M M M
TOOLS

Termo on M M M M
Defrost M M M M
Coil In/Out temperature M M M M
TECHNICAL
DRAWINGS

M : Modbus / R : Resistance / V : Voltage / C: control


* : only when room is occupied / ** : setpoint limitation / (*) if available
*** : no fan speed control on the CYV air curtain / **** : run & fault
PREVIOUS

147
Standard protocol interfaces

Modbus Interface RTD-20 retail economiser


RTD Control zones in shop applications

RTD-NET Zoning
›› Modbus interface for monitoring and control
Stockroom
of Sky Air, VRV, VAM and VKM
Reduce energy costs for
non-comfort areas by
RTD-10 setting a different, wider
›› Advanced integration into BMS of Sky Air, VRV, temperature band
VAM and VKM through either:
- Modbus
- Voltage (0-10V)
- Resistance
›› Duty/standby function for server rooms
Retail zone
Timer sets pre-trade,
trade and post-trade Kitchen
RTD-20
conditions Individual control by the staff
›› Retail economisor
›› Advanced control of Sky Air, VRV, VAM/VKM
Changing rooms
and air curtains
›› Clone or independent zone control Custom settings to provide
›› Increased comfort with integration of CO2 sensor a warmer zone for changing
for fresh air volume control rooms for maximum customer
›› Save on running costs via comfort
- pre/post and trade mode
- set point limitation
- overall shut down
- PIR sensor for adaptive deadband Control options benefits
Optimize the operation of the air conditioning
without compromising occupant comfort
RTD-HO
›› Modbus interface for monitoring and control of
Sky Air, VRV, VAM and VKM Without RTD-20 With RTD-20
›› Intelligent hotel room controller ›› Pre-trade: ›› Pre-trade:
• AC either on (timer) or off • De-stratification on start-up
• whole store heated or cooled • Heat/Cool protection enabled
›› Trading: • AC only comes on if internal
• achieving set-point temp above 26°C or below 19°C
• staff could access controllers • achieving midpoint of 19-23°C
• heat cool clash can occur • controllers locked
• door curtain not interlocked • heat cool clash prevented
• always trying to achieve set-point • door curtain interlocked
›› Post-Trade: • learns store patterns & heats/
• either on or off cools “enough” to reach set-point
›› Post-Trade:
• Heat/cool protection enabled
• Trade extension function

Integrate all essential store operations in one control


Optimize the operation of the air conditioning without compromising occupant
comfort.
Accumulated kWh
70000
Up to 35%
60000
saving!
50000
40000
30000
20000   Occupied year 1
10000   Occupied year 2
0
0 500 1000 1500 2000 2500 Accumulated heating + cooling degree days

148
SKY AIR INTRO
Overview functions

Overview functions

INDOOR
UNITS
OUTDOOR
Main functions RTD-NET RTD-10 RTD-20 RTD-HO

UNITS
Dimensions HxWxD mm 100 x100 x 22
Key card + window contact 
Set back function 
Prohibit or restrict remote control functions (setpoint limitation, ...)   ** 
Modbus (RS485)    
Group control    
0 - 10 V control  

AIR CURTAINS
Resistance control  

BIDDLE
IT application 
Heating interlock  
Output signal (on/defrost, error)  **** 
Retail application 
Partitioned room control 
Air curtain *** *** 
(1): By combining RTD-RA devices

VENTILATION
Control functions RTD-NET RTD-10 RTD-20 RTD-HO
On/Off M M,V,R M M*
Set point M M,V,R M M*
Mode M M,V,R M M*
fan M M,V,R M M*
Louver M M,V,R M M*
HRV Damper control M M,V,R M

CONTROL
SYSTEMS
Prohibit/Restrict functions M M,V,R M M*
Forced thermo off

Monitoring functions RTD-NET RTD-10 RTD-20 RTD-HO


On/Off M M M M
Set point M M M M

& ACCESSORIES
Mode M M M M

OPTIONS
fan M M M M
Louver M M M M
RC temperature M M M M
RC mode M M M M
nbr units M M M M
Fault M M M M
Fault code M M M M
Return air temperature (Average /Min/Max) M M M M
& PLATFORMS

Filter alarm M M M M
TOOLS

Termo on M M M M
Defrost M M M M
Coil In/Out temperature M M M M
TECHNICAL
DRAWINGS

M : Modbus / R : Resistance / V : Voltage / C: control


* : only when room is occupied / ** : setpoint limitation / (*) if available
*** : no fan speed control on the CYV air curtain / **** : run & fault
PREVIOUS

149
Standard protocol interfaces

DIII-net Modbus interface


EKMBDXA
Integrated control system for seamless connection between
Split, Sky Air, VRV and small inverter chillers and BMS systems
›› Communication via Modbus RS485 protocol
›› Detailed monitoring and control of the VRV total solution
›› Easy and fast installation via DIII-net protocol
›› As the Daikin DIII-net protocol is being used, only one modbus interface is needed for a group of Daikin systems
(up to 10 outdoor unit systems).

VRV network

DIII- NET

EKMBDXA VRV Outdoor unit

Biddle air curtain HRV


*via EKEQ box up to 64 units connectable per interface

Sky Air network*

Split network*

KRP928BB2S

Small inverter chiller network

Building
control
network Fire alarm Security Power supply facility Lighting Pump Elevator

* Additional centralized controller might be required. For more information contact your local dealer.

EKMBDXA7V1
Maximum number of connectable indoor units 64
Maximum number of connectable outdoor units 10
Communication DIII-NET - Remark DIII-NET (F1F2)
Protocol - Remark 2 wire; communication speed: 9600 bps or 19200 bps
Protocol - Type RS485 (modbus)
Protocol - Max. Wiring
m 500
length
Dimensions HeightxWidthxDepth mm 124x379x87
Weight kg 2.1
Ambient temperature - operation Max. °C 60
Min. °C 0
Installation Indoor installation
Power supply Frequency Hz 50
Voltage V 220-240

150
SKY AIR INTRO
Standard protocol interfaces

KNX interface
KLIC-DI

INDOOR
UNITS
Integration of Sky Air and VRV in HA/BMS systems

OUTDOOR
UNITS
Connect Sky Air / VRV indoor units to
KNX interface for BMS integration
light

shop
Concept

AIR CURTAINS
Domotica shutter control

BIDDLE
Controller tv
Interface Daikin protocol/ KNX

VENTILATION
KNX interface line-up
The integration of Daikin indoor units through
the KNX interface allows monitoring and control a range of commands to be executed simultaneously

CONTROL
SYSTEMS
of several devices, such as lights and shutters, from once the scenario is selected. For instance in
one central controller. One particularly important “Home leave” , the air conditioner is off, the lights are
feature is the ability to programme a ‘scenario’ turned off, the shutters are closed and the alarm is on.
- such as “Home leave” - in which the end-user selects

& ACCESSORIES
OPTIONS
& PLATFORMS

KNX interface for


TOOLS

KLIC-DI Size 90x60x35mm


Sky Air VRV
Basic control
On/Off • •
Mode Auto, heat, dry, fan, cool Auto, heat, dry, fan, cool
Temperature • •
TECHNICAL
DRAWINGS

Fan speed levels 2 or 3 2 or 3


Swing Stop or movement Swing or fixed positions (5)

Advanced functionalities
Error management Communication errors, Daikin unit errors
Scenes • •
Auto switch off • •
Temperature limitation • •
Initial configuration • •
PREVIOUS

Master and slave configuration • •

151
Room sensors

Wireless room temperature sensor


K.RSS

Flexible and easy installation

›› Accurate temperature measurement thanks to flexible


placement of the sensor
›› No need for wiring
›› No need to drill holes
›› Ideal for refurbishment

Connection diagram Daikin indoor unit PCB (FXSQ example)

Power supply – X35, X13

Air sensor – X16A, X19

Rf Receiver RF sender

Specifications
Wireless room temperature sensor kit (K.RSS)
Wireless room temperature receiver Wireless room temperature sensor
Dimensions mm 50 x 50 ø 75
Weight g 40 60
Power supply 16VDC, max. 20 mA N/A
Battery life N/A +/- 3 years
Battery type N/A 3 Volt Lithium battery
Maximum range m 10
Operation range °C 0~50
Type RF
Communication
Frequency MHz 868.3

›› Room temperature is sent to the indoor unit every 90 seconds or if the temperature difference is 0.2°C or larger.

Wired room temperature sensor


KRCS01-1B
KRCS01-4B

›› Accurate temperature measurement,


thanks to flexible placement of the sensor

Specifications
Dimensions (HxW) mm 60 x 50
Weight g 300
Length of branch wiring m 12

152
SKY AIR INTRO
Other integration devices

ADAPTER PCBs
Simple solutions for unique requirements
Concept and benefits

INDOOR
UNITS
›› Low cost option to satisfy simple control
requirements
Connectable to:
›› Deployed on single or multiple units
Split Sky Air VRV

OUTDOOR
(E)KRP1B* • Facilitates integration of auxiliary heating apparatus, humidifiers, fans, damper
 

UNITS
adapter for wiring • Powered by and installed at the indoor unit

• Remotely start and stop up to 16 indoor units (1 group) (KRP2A* via P1 P2)
KRP2A*/KRP4A* • Remotely start and stop up to 128 indoor units (64 groups) (KRP4A* via F1 F2)
Wiring adapter for
electrical appendices


Alarm indication/ fire shut down
Remote temperature setpoint adjustment
 
• Cannot be used in combination with a central controller

AIR CURTAINS
BIDDLE
KRP58M3 • Low noise and demand control option for RZQ200/250C 
• Low noise and demand control option for RZQG and RZQSG single phase
SB.KRP58M51
• Includes mounting plate EKMKSA1 

VENTILATION
KRP58M51 • Low noise and demand control option for RZQG1 and RZQSG 3 phase 

DTA104A* • Individual or simultaneous control of VRV system operating mode


Outdoor Unit External
Control Adapter
• Demand control of individual or multiple systems
• Low noise option for individual or multiple systems

• Enables unified display (operation/malfunction) and unified control (ON/OFF) from BMS

CONTROL
SYSTEMS
DCS302A52 system
Unification adapter for
computerized control
• Must be used together with Intelligent Touch Controller or intelligent Touch Manager
• Cannot be combined with KRP2/4*

• Can be used for all VRV indoor models

KRP928*
Interface adapter for
DIII-net
• Allows integration of split units to Daikin central controls 

& ACCESSORIES
KRP413* • Switch off auto restart after power failure

OPTIONS
Wiring adapter normal • Indication of operation mode / error
open contact / normal
open pulse contact


Remotely start /stop
Remotely change operation mode

• Remotely change fan speed

KRP980* • Connect a wired remote control


Adapter for split units
without an S21 port
• Connect to Daikin central controls
• Allow external contact

Some adapters require an installation box, refer to the option lists for more information
& PLATFORMS
TOOLS

Accessories
• External ON/OFF or forced off
EKRORO
• Example: door or window contact

• External ON/OFF or forced off


EKRORO 3 • F1/F2 contact
TECHNICAL
DRAWINGS

• Example: door or window contact

• Mechanical cool/heat selector


KRC19-26A • Allows switching over an entire system between cooling/heating/fan only
• Connects to the A/B/C terminals of the unit

• Cool/heat selector PCB


BRP2A81 • Required to connect KRC19-26A to a VRV IV outdoor unit
PREVIOUS

153
Options & accessories

AUTO-CLEANING PANEL

FILTERS

INTELLIGENT SENSORS

154
Sky Air
Indoor units
Outdoor units

Ventilation
Air handling units
161
160
258
156
156
Options &
accessories

155
TECHNICAL TOOLS OPTIONS CONTROL BIDDLE OUTDOOR INDOOR
PREVIOUS VENTILATION SKY AIR INTRO
DRAWINGS & PLATFORMS & ACCESSORIES SYSTEMS AIR CURTAINS UNITS UNITS
Options - Sky Air
FCAHG-G
FFA-A FDBQ-B FDXM-F3 FBA-A FDA-A
INDOOR UNITS FCAG-A

BYCQ140D (standard)
BYCQ140DW (white)(1) BYFQ60CW (white)
Decoration panel
BYCQ140DG9/ BYFQ60CS (silver)
(obligatory for cassette units, optional for others)
BYCQ140DGF9 BYFQ60B3 (standard)
(auto-cleaning)(2)(4)
Panels

KDBQ44B60 (only
Panel spacer for reducing required installation height
for standard panel)
Sealing kit for 3- or 2-directional air discharge KDBHQ55B140 (11) BDBHQ44C60
BRYQ60AW (white)(9)
Sensor kit BRYQ140A
BRYQ60AS (silver)(9)
BRP069A81 - Online Controller     
BRC7EB530W
for standard panel (5)(6)
Infrared remote control (incl. receiver) BRC7FA532F (11) BRC7F530W BRC4C65 BRC4C65 BRC4C65
Individual control systems

for white panel (5)(6)


BRC7F530S - for silver panel (5)(6)
BRC1H51W (Glossy white) / BRC1H51S (Metallic silver) / BRC1H51K
(Black matte) - User-friendly wired remote controller with premium      
design
BRC1E53A/B/C (3) (13) - Wired remote control with full-text
     
interface and back-light
BRC1D52 (13) - Standard wired remote control with weekly timer      
BRC2E52C (3) (13) - Simplified remote control (with operation mode
     
selector button)
BRC3E52C (3) (13) - Simplified remote control (without operation
     
mode selector button)
ARCWB - Wired remote controller
DIII-net connection - for connection to centralized control standard standard standard standard standard
Centralised control

DCC601A51 - Intelligent tablet controller      


DCS601C51 (13) - Intelligent touch controller      
systems

DCS302C51 (13) - Central remote control      


DCS301B51 (13) - Unified ON/OFF control      
DST301B51 (13) - Schedule timer      
NIM03 - R04084124324 - Option PCB for group control
DCM601A51 - Intelligent Touch Manager      
System & Standard protocol

RTD-NET - Modbus interface for monitoring and control      


Building Management

RTD-10 - Modbus interface for infrastructure cooling      


RTD-20 - Modbus interface for retail      
interface

RTD-HO - Modbus interface for hotel      


EKMBDXA - Modbus interface      
KLIC-DI - KNX Interface      
DCM010A51 - Daikin PMS interface      
DMS502A51 - BACnet Interface      
DMS504B51 - LonWorks Interface      

Replacement long-life filter, non-woven type KAFP551K160 KAFQ441BA60


Filters

BAE20A62 (25 - 35)


Auto cleaning filter see deco panel
BAE20A102 (50 - 60)
Wiring adapter for external monitoring/control via dry
KRP4A53 (10)(11) KRP4A53 (10) KRP4A54 (10) KRP4A52 (10)
contacts and setpoint control via 0-140 Ω
Wiring adapter with 2 output signals
KRP1B57 (10)(11) KRP1B57 (10) KRP1B56 (10)
(compressor/ Error, Fan output)
Wiring adapter for external central monitoring/control
KRP2A53 (10) KRP2A51 (7)(10) KRP2A51 (8)
(controls 1 entire system)
Adapter for wiring (interlock for fresh air intake fan) KRP1B54 KRP1C64 (7)
Wiring adapter with 4 output signals
EKRP1C11 (10)(11) EKRP1B2 EKRP1B2 EKRP1B2 (7) EKRP1B2 (7)
Adapter

(compressor / Error, Fan, Aux, heater, Humidifier output)


Adapter for keycard or window contact connection
BRP7A53 BRP7A53 BRP7A53 BRP7A54 (10) BRP7A51 (12) BRP7A54 (12)
(in combination with BRC1H*, BRC1/2/3E* only)
Installation box/Mounting plate for adapter PCBs (when there is no
KRP1H98 (11) KRP1B101/KRP1BA101 KRP1BA101 KRP1B101/KRP1BA101 KRP4A96
space in the switchbox, an installation box is required)
External wired temperature sensor KRCS01-4 KRCS01-4 KRCS01-1 KRCS01-4 KRCS01-4 KRCS01-4
K.RSS - External wireless temperature sensor     
Remote ON/OFF, forced OFF kit standard standard standard standard standard EKRORO3
DTA112B51 - Interface adapter for Sky Air 
Drain pump kit
2 dampers (35 - 50)
3 dampers (35 - 50)
2 dampers (25 - 35)
Multi zoning kit 4 dampers (35 - 71)
3 dampers (25 - 35)
(for detailed model code overview refer to multizoning argue card 5 dampers (60 - 140)
4 dampers (50)
in this catalogue) 6 dampers (60 - 140)
5 dampers (60)
7 dampers (100 - 140)
Others

8 dampers (100 - 140)

L-type piping kit (upward direction)

KDDQ55B140-1 +
Fresh air intake kit (direct installation type) KDDQ44XA60
KDDQ55B140-2 (11)
KDAP25A56A (35-50)
Air discharge adapter for round duct KDAP25A71A (60-71) KDAJ25K140A
KDAP25A140A [100-140)

(1) Dirt formation is more easily visible on white insulation. It is recommended not to install this (3) Included languages are:
option in environments with a high concentration of dirt. A: English, German, French, Dutch, Spanish, Italian and Portuguese
(2) To be able to control option BYCQ140DG(F)9, controller BRC1H*, BRC1E* is needed. These B: English, Bulgarian, Croatian, Czech, Hungarian, Romanian and Slovenian
options cannot be combined with RXYSQ*, multi or non-inverter split units C: English, Greek, Polish, Russian, Albanian, Slovak and Turkish (in case of BRC2/3E52C
Serbian is available instead of Albanian)
For BRC2/3E52C use PC cable EKPCCAB3 in combination with the updater PC software to
change to language pack B or C
156
SKY AIR INTRO
FDQ-B ADEQ-C ABQ-C FHA-A AHQ-C FUA-A FAA-A FVA-A FNA-A

INDOOR
UNITS
KDBHP49B140 +
KDBTP49B140

     

BRC4C65 BRC4C65 BRC7G53 BRC7CB58 BRC7EB518 BRC4C65

OUTDOOR
UNITS
     

     

      

     

     

AIR CURTAINS
 
DTA112B51 standard standard standard standard standard

BIDDLE
     
     
     
     
     
 
     
     

VENTILATION
     
     
     
     
     
     
     
     
KAFP501A56 (35-50)
KAFP501A80 (60-71) KAFP551K160 KAFJ95L160
KAFP501A60 (100-140)

CONTROL
SYSTEMS
KRP4A51 (8) KRP4A52 (10) KRP4A53 (10) KRP4A51 (10) KRP4A52 (10) KRP4A54

KRP1B57 (10)

KRP2A51 (8)

KRP1B54 (8) KRP1B59 KRP1B54 (10)

& ACCESSORIES
EKRP1B2 (7)(8) EKRP1B2A (7) KRP1B56

OPTIONS
BRP7A54 (8) BRP7A52 (10) BRP7A53 (10) BRP7A51 (10) BRP7A52 BRP7A51

KRP1D93A [box)
KRP4A96 KKSAP50A56 (35-50) KRP1BA97 KRP4A93 KRP4AA95 KRP1BA101
[mounting plate)
KRCS01-1 KRCS01-4 KRCS01-4 KRCS01-4 KRCS01-4
    
EKRORO standard standard

KDUP50Q63 (35 - 60)
& PLATFORMS

K-KDU572EVE
KDUP50Q160 (71 - 140)
TOOLS

4 dampers (71)
5 dampers (71 - 125)
6 dampers (71 - 125)
7 dampers (100 - 125)
8 dampers (100 - 125)

KHFP5MA35 (35)
KHFP5N63 (50-60)
KHFPN5N160 (71-140)
KDDQ50A140
TECHNICAL
DRAWINGS

KDAP25A71A (71)
KDAP25A140A
(100/125)

(4) The option is intended exclusively for use in fine dust enviornments (e.g. Clothing shops). (8) Mounting plate KRP4A96 is required for these options. Maximum 2 option PCB’s can be
Do not use it in environments that are greasy or have high humidity. mounted.
(5) Sensing function is not available (9) This option cannot be used with RR and RQ models
(6) Individual flap control function not available (10) Requires installation box for adapter PCB, refer to table for model code
PREVIOUS

(7) If installing an electrical heater, an option PCB for external electrical heater (EKRP1B2) for (11) This option cannot be combined with BYCQ140DG(F)9
each indoor unit is required. These options require mounting plate KRP4A96. Electrical (12) Maximum 2 optional PCBs can be mounted
heaters and humidifiers are field-supplied. Do not install them inside the equipment. (13) Applicable boxes (KJB*) to mount controllers can be found in the controls option list
157
R-32
RZAG-MV1/MY1 RZASG-MV1/MY1 AZAS-MV1/MY1
Refrigerant branch

for twin KHRQ22M20TA KHRQ22M20TA


piping

for triple KHRQ127H (100 - 140) KHRQ127H (100 - 140)

for double twin KHRQ22M20TA (3x) (125 - 140) KHRQ22M20TA (3x) (125 - 140)

Demand adapter kit SB.KRP58M52 SB.KRP58M52 SB.KRP58M52

Bottom plate heater EKBH140L7

R-410A
RZQG-L9V1 RZQG-L(8)Y1 RZQSG-L3V1 RZQSG-L(8)Y1 AZQS-B8V1 AZQS-BY1 RZQ-C
Drain plug KWC26B280
KHRQ22M20TA KHRQ22M20TA
For twin KHRQ22M20TA KHRQ22M20TA KHRQ22M20TA
Refrigerant branch

(KHRQ58T) (1) (KHRQ58T) (1)


KHRQ127H KHRQ127H
KHRQ127H KHRQ127H
For triple (100 - 140) (100 - 140) KHRQ250H7
(100 - 140) (100 - 140)
(KHRQ58H) (1) (KHRQ58H) (1)
KHRQ22M20TA KHRQ22M20TA
KHRQ22M20TA (x3) KHRQ22M20TA (x3) KHRQ22M20TA (x3)
For double twin (x3) (125 - 140) (x3) (125 - 140)
(125 - 140) (125 - 140)
(KHRQ58T) (1) (KHRQ58T) (1)
KRP58M51 (71) KRP58M51 (71)
Demand adapter kit SB.KRP58M51 KRP58M51 SB.KRP58M51 KRP58M51 SB.KRP58M51 KRP58M51 KRP58M51
(100 - 125 - 140) (100-140)

Bottom plate heater EKBPH140L7 EKBPH140L7 (2)

(1) For RZQG-L(8)Y1 in combination with FCAG35-71* or FCAHG-* use refrigerant branch piping between brackets
(2) For combination of RZQG71 and EKBPH140L7 the demand adapter kit is needed in order to connect the bottom plate heater

158
159
TECHNICAL TOOLS OPTIONS CONTROL BIDDLE OUTDOOR INDOOR
PREVIOUS VENTILATION SKY AIR INTRO
DRAWINGS & PLATFORMS & ACCESSORIES SYSTEMS AIR CURTAINS UNITS UNITS
Options & accessories

Ventilation

VAM VAM VAM VAM VAM VAM VAM VAM VAM


150FC 250FC 350FC 500FC 650FC 800FC 1000FC 1500FC 2000FC

Dust filters EN779 Medium M6 - - EKAFV50F6 EKAFV50F6 EKAFV80F6 EKAFV80F6 EKAFV100F6 EKAFV100F6 x2 EKAFV100F6 x2

EN779 Fine F7 - - EKAFV50F7 EKAFV50F7 EKAFV80F7 EKAFV80F7 EKAFV100F7 EKAFV100F7 x2 EKAFV100F7 x2

EN779 Fine F8 - - EKAFV50F8 EKAFV50F8 EKAFV80F8 EKAFV80F8 EKAFV100F8 EKAFV100F8 x2 EKAFV100F8 x2

Silencer Model name - - - KDDM24B50 KDDM24B100 KDDM24B100 KDDM24B100 KDDM24B100 x2 KDDM24B100 x2


Nominal pipe
- - - 200 200 250 250 250 250
Diameter (mm)
CO2 sensor - - BRYMA65 BRYMA65 BRYMA65 BRYMA100 BRYMA100 BRYMA200 BRYMA200

VH electrical heater for VAM VH1B VH2B VH2B VH3B VH3B VH4B / VH4/AB VH4B / VH4/AB VH5B VH5B

Individual control systems VAM-FC EKEQFCBA 2 EKEQDCB 2 EKEQMCBA 2


Wired remote control BRC1E52A/B / BRC1D52 BRC1E52A/B / BRC1D52 BRC1E52A/B / BRC1D52 1 BRC1E52A/B / BRC1D52 1

VAM wired remote control BRC301B61 - - -

Centralised control systems VAM-FC EKEQFCBA 2 EKEQDCB 2 EKEQMCBA 2


Centralised remote control DCS302C51 - - -

Unified ON/OFF control DCS301B51 - - -

Schedule timer DST301B51 - - -

DCC601A51 DCC601A51 - - -

Intelligent Touch Manager DCM601A51 DCM601A51 DCM601A51 DCM601A51

Modbus DIII adapter EKMBDXA7V1 EKMBDXA7V1 EKMBDXA7V1 EKMBDXA7V1

BACnet interface DMS502A51 - - -

LonWorks interface DMS504B51 - - -

Others VAM150-250FC VAM350-2000FC EKEQFCBA 2 EKEQDCB 2 EKEQMCBA 2


Wiring adapter for electrical appendices
KRP2A51 KRP2A51 (note 3) - - -
(note 7)
Adapter PCB for humidifier KRP50-2 KRP1C4 (note 4/6) - - -

Adapter PCB for 3rd party heater BRP4A50 BRP4A50A (note 4/5) - - -

Remote sensor - - - KRCS01-1 -

Notes
(1) Cool/heat selector required for operation
(2) Unless otherwise specified DIII-net devices cannot be connected to the system
(3) Installation box KRP1BA101 needed.
(4) Fixing plate EKMPVAM additionally needed for VAM1500-2000FB.
(5) 3rd party heater and 3rd party humidifier cannot be combined
(6) Installation box KRP50-2A90 needed.
(7) For external control and monitoring (ON/OFF control, operation signal, error indication)

VH electrical heater for VAM


Supply voltage 220/250V ac 50/60 Hz. +/-10%
Output current (maximum) 19A at 40°C (ambient)
Temperature sensor 5k ohms at 25°C (table 502 1T)
Temperature control range 0 to 40°C / (0-10V 0-100%)
Run on timer Adjustable from 1 to 2 minutes (factory set at 1.5 minutes)
Control fuse 20 X5 mm 250 m A
LED indicators Power ON - Yellow
Heater ON - Red (solid or flashing, indicating pulsed control)
Airflow fault - Red
Mounting holes 98mm X 181mm centres 5 mm ø holes
Maximum ambient adjacent to terminal box 35°C (during operation)
Auto high temp. cutout 100°C Pre-set
Man. reset high temp. cutout 125°C Pre-set
Run relay 1A 120V AC or 1A 24V DC
BMS setpoint input 0-10VDC

Vh electrical heater for vam vH1B VH2B VH3B VH4B VH4/AB VH5B
Capacity kW 1 1 1 1.5 2.5 2.5
Duct diameter mm 100 150 200 250 250 350
Connectable VAM VAM150FC VAM250FC VAM500FC VAM800FC VAM800FC VAM1500FC
- VAM350FC VAM650FC VAM1000FC VAM1000FC VAM2000FC

160
SKY AIR INTRO
Options & accessories

D-AHU Professional

Construction type SP 65 SP 45 FP 50 FP 25
Aluminium standard standard standard standard

INDOOR
Anodized aluminium option option option option

UNITS
Profile
Aluminium with thermal break option option option option
Anodized aluminium with thermal break option option option option
Corner Glass fibre reinforced nylon standard standard standard standard
Polyurethane foam density 45 kg/m3 thermal
standard standard standard standard
conductivity 0.020 W/m*K fire reaction class 1
Panel insulation
Mineral wool density 90 kg/m3 thermal conductivity
option option option option
0.037 W/m*K (referred to 20°C) fire reaction class 0

OUTDOOR
UNITS
Grey Plastisol covered galvanized steel standard standard standard standard
Pre-coated galvanized steel option option option option
External sheet
Galvanized steel option option option option
material
Aluminium option option option option
AISI 304 stainless steel option option option option
Galvanized steel standard standard standard standard
Pre-coated galvanized steel option option option option

AIR CURTAINS
Internal sheet material Grey Plastisol covered galvanized steel option option option option

BIDDLE
Aluminium option option option option
AISI 304 stainless steel option option option option
standard standard standard standard
Aluminium
(from size 1 to size 17) (from size 1 to size 17) (from size 1 to size 17) (from size 1 to size 17)
Base frame
standard standard standard standard
Galvanized steel
(from size 18 to size 27) (from size 18 to size 27) (from size 18 to size 27) (from size 18 to size 27)
Handle Glass fibre reinforced nylon standard standard standard standard

VENTILATION
Compression type standard standard standard standard
Type Hinge function type
option option option option
(possibility to remove door)

D-AHU Easy

CONTROL
SYSTEMS
Construction type DS 50 DS 25
Profile Aluminium Standard Standard
Corner Glass fibre reinforced nylon Standard Standard
Panel insulation Polyurethane foam thermal conductivity 0.024 W/m*K Standard (density 45 kg/m3) standard (density 47 kg/m3)
External sheet material Pre-coated galvanized steel (RAL 9002) Standard Standard
Internal sheet material Galvanized steel Standard Standard

& ACCESSORIES
Base frame Aluminium Standard Standard

OPTIONS
Handle Glass fibre reinforced nylon Standard Standard
Type Compression type Standard Standard

& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

161
We’re here to help you!
Online and offline

http://literature.daikinpromoshop.eu

General catalogue

2017

162
Literature overview 
Supporting tools, software and apps 
166
164
platforms
Tools and

163
TECHNICAL TOOLS OPTIONS CONTROL BIDDLE OUTDOOR INDOOR
PREVIOUS VENTILATION SKY AIR INTRO
DRAWINGS & PLATFORMS & ACCESSORIES SYSTEMS AIR CURTAINS UNITS UNITS
Commercial market - literature overview
for professional network
Solution
guides:

Reference
books:

Product VRV IV range Keep looking


i
VRV IV i-series Sky Air Water-to-air
profiles: VRV IV
Detailed VRV IV you’ll never find me Main benefits, A-series heat pump
standards and application examples Our mission
360° efficiency Achieve
the lowest Main benefits Detailed info on
technologies and specs of VRV IV environmental
impact and specs VRV IV W-series,
benefits. Main i-series product range application
VRV IV heat pumps for indoor installation

features and Expected


207 116 examples, techni-
specs of VRV IV
cal system design
VRV IV heat recovery, heat pump, replacement
and water cooled
product range VRV IV S-series background
Introducing the new Sky Air A-series with
ultra-efficient Bluevolution R-32 technology

Keep looking
you’ll never find me Main benefits,
206 application examples 209
and specs of VRV IV
Compact VRV IV heat pumps
for residential and light commercial applications
S-series product range
208

Focus Replacement Infrastructure cooling


topics: Technology ON
TINUOUS O Clear installer benefits
C

PE
RELIABLE,

Replacement why to choose Daikin for


RATION

Infrastructure
technology Clear installer benefits cooling solution
for installers
of VRV replacement infrastructure cooling
technology

› For server rooms, telecom shelters, laboratories, IT applications

214 140
The quick and quality way of upgrading R-22 and R-407C systems

Product
Real time clock

Real time clock with auto update to daylight saving


time

Supports multiple languages


Possibility to individually restrict menu
functions/buttons

› Restrict some of all functions on the remote


control to void misuse in e.g. hotels, shops, offices
Wired Remote Control Split, Sky Air, VRV, Chillers,
Refrigeration, Daikin Altherma
RTD modbus interface
Detailed info on Detailed info on RTD
Other features

flyers:
› English, German, French, Spanish, Italian,
Portuguese, Greek, Dutch, Russian, Turkish › Built-in back-up power. When a power failure occurs,
and Polishr (BRC1E52A) all settings remain stored up to 48 hours

› English, German, Czech, Croation, Hungarian, › Backlight display


Romanian, Slovenian, Bulgarian, Slovak, Serbian,
Albanian (BRC1E52B)

Modbus
Specifications / Functions
Specifications
Dimensions (HxWxD)
Display size (HxW)
BRC1E52A / BRC1E52B
3.120x120x19 mm40
43.2x68.85 mm
User friendly
remote control BRC1E52A/B remote Interface controls and applications
with contemporary
control
LCD
Type Full dot (160x255)
Colour
Cover for operation part
Max. wiring length
Fresh white
No
500m
RTD
design
Connectable indoor units All VRV® and Sky Air® indoor units

Functions BRC1E52A / BRC1E52B


Set sensor behavior —
Temperature range limit —
Energy saving
functions
Setback function
Set point auto reset
—
— BRC1E52A/B
Off timer —
Multilingual display English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, Polishr English, German, Czech, Croation, Hungarian, Romanian, Slovenian, Bulgarian, Slovak, Serbian, Albanian
Help menu —
Room temperature display —
Display
Clock (time display) Real time clock with auto update to daylight saving time
Backlight —
Contrast adjustment —
Weekly schedule timer 3
Timer
Holiday function —
Key lock —
Access control Restrict menus Each menu individually
Restrict buttons Each button individually (ON/OFF, operation mode selector, temperature adjustment, fan speed / air flow direction)
Memory Built-in back-up power When a power failure occurs, all settings remain stored up to 48 hours

› Easy to use: all main functions directly accessible › Set up to 3 independent schedules, so the user can
easily change the schedule himself throughout the
Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor) › Easy commissioning: intuitive interface for advanced year (e.g. summer, winter, mid-season)
menu settings
› Real time clock with auto update to daylight saving
FSC › Optimise your air conditioning system by activating a time
series of energy saving functions (temperature range
ECPEN15 - 306 180 · 11/14 limit, setback function, off timer, …) › Supports multiple languages Integration of Daikin portfolio in BMS system via Modbus
The present publication is drawn up by way of information only and does not constitute an offer binding upon

308
Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No
› Indoor unit control › Retail applications

306
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its › Keep track of your energy consumption with the › Possibility to individually restrict menu functions
content and the products and services presented therein. Specifications are subject to change without prior notice.
kWh indication showing an indicative electricity via 0~10 volt, dry contact › Hotel applications
Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from
or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. consumption › When a power failure occurs all settings remain stored or resistance contact › IT applications
The present publication supersedes ECPEN12-306. Printed on non-chlorinated paper. up to 48 hours thanks to the built-in backup power › Heating interlock
› Alarm signal

Product Sky Air Catalogue VRV Catalogue Ventilation Catalogue


catalogues: Sky Air
Detailed technical
VRV
Detailed technical Detailed info on
Product catalogue 2017
for professionals
information & benefits
Auto cleaning filter for
concealed ceiling units
New pre-sized
fresh air solution
Product catalogue 2017
for professionals
information & benefits of Ventilation products
on Sky Air/Ventilation/ the VRV total solution
A unique UNIQUE
Patents
Select your AHU Order AHU
and outdoor
success story repeated pending like any other VRV indoor in one step

Reduced runningcosts Easy selection


Improved room air quality Fast quotation

Biddle Air Curtain/Control


Minimal time required for filter cleaning Easy ordering
Unique technology Easy installation
VRV Product catalogue 2017 for professionals

airflow

systems/AHU
direction

R-32
IS AN
INDUSTRY
REVO
LUTIO
BE PART N.
NEW
Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)
OF IT. Daikin Europe N.V. participates in the Eurovent Certification
programme for Liquid Chilling Packages (LCP), Air handling

FSC units (AHU), Fan coil units (FCU) and variable refrigerant flow
systems (VRF) Check ongoing validity of certificate online: webbase
www.eurovent-certification.com or using: www.certiflash.com
Xpress d
Get ahead of competition
ECPEN17 - 200 12/16
selec Minimum running costs, maximum flexibility.
software tion

100 200 203


Fast installation, top reliability, perfect comfort.
The present publication is drawn up by way of information only and does not constitute an offer binding upon
Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its
content and the products and services presented therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from
or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.

The present publication supersedes ECPEN16-200. Printed on non-chlorinated paper.

164
SKY AIR INTRO
Tools and platforms

for your customers

INDOOR
UNITS
Commercial Solutions Green Buiding Solutions
Daikin offers solutions for Green building
Clear building owner/investor
benefits why to choose Daikin
Commercial solutions
solutions
for small to large applications
commercial applications
for a green building, with
emphasis on BREEAM
365-days climate comfort for every business

216
100
Sustainable design
with Daikin HVAC-R systems

Reference

OUTDOOR
UNITS
catalogue
Daikin commercial Hotel Solutions
and industrial Hotel solutions
Clear building owner/investor
references for hotel owners
benefits why to choose Daikin
Heating - air conditioning - hot water - ventilation - refrigeration - control
for a hotel
218
213

AIR CURTAINS
Intelligent Touch Manager Tablet
DCC601A51
Detailed benefits of Detailed benefits of DCC601A51

BIDDLE
Control systems

Intelligent Touch
Intelligent Touch Manager intelligent
Tablet Controller and Daikin Cloud Service
with cloud connection
Manager

Mini Building Management System

302 303
Your business at your fingertips

VENTILATION
SPLIT, SKY AIR, VRV, CHILLERS Replacement technology
Clear building owner/investor
benefits of replacement
The phase-out period for
R-22 is over.
Act now!
technology

CONTROL
SYSTEMS
Avoid loss of business and replace your air conditioning
system now!

215

Sky Air product leaflets VRV product leaflets


Concealed
Single page leaflet with the Single page leaflet with the
floor standing
main benefits and technical Concealed
main benefits and technical

& ACCESSORIES
unit ceiling unit
FNQ-A, FXNQ-A with medium
specifications of each ESP
specifications of each individual

OPTIONS
FBQ-D, FXSQ-A

individual Sky Air unit. Ideal for VRV unit. Ideal for quotations
quotations
Designed to be concealed in walls Optimum comfort guaranteed no matter the
Home leave
Home leave length of ductwork or type of grilles
operation
operation › Ideal for installation in offices, hotels and residential › Discretely concealed in the wall, leaving only the
› Top efficiency in the market › Medium external static pressure up to 150Pa facilitates
applications suction and discharge grilles visible
› Automatic air flow adjustment function measures the using flexible ducts of varying lengths
› Its low height enables the unit to fit perfectly beneath › Requires very little installation space as the depth is
air volume and static pressure and adjusts it towards › Reduced energy consumption thanks to specially
a window only 200mm
Powerful mode the nominal air flow, whatever the length of duct, developed DC fan motor
Powerful mode › High ESP allows flexible installation
making installation easier and guaranteeing comfort. › Flexible installation, as the air suction direction can be
Moreover, the ESP can be changed via the wired altered from rear to bottom suction
remote control to optimize the supply air volume › Standard built-in drain pump increases flexibility and
Multi tenant
Multi tenant (FXSQ) › Slimmest unit in class, only 245mm installation speed
(FXNQ-A)
› Discretely concealed in the ceiling: only the suction › No optional adapter needed for DIII-connection, link
and discharge grilles are visible your unit into the wider building management system
› Low sound level

& PLATFORMS
TOOLS

Technical documentation:
TECHNICAL
DRAWINGS

All latest Daikin catalogues are available in


a convenient library on the internet:
www.daikineurope.com/support-and-manuals/catalogues
PREVIOUS

165
Tools and platforms

Supporting www.daikineurope.com/
support-and-manuals/

tools, software and apps software-downloads

Software
Ventilation Xpress

Selection tool for ventilation devices (VAM, VKM). The


selection is based on given supply/extract airflows
(including fresh up and given ESP of supply/extract
ducting:
›› Determines size of electrical heaters
›› Visualisation of psychrometric chart
›› Visualisation of selected configuration
›› Required field settings mentioned in the report

Webbased ASTRA selection NEW WAGO selection tool NEW


for air handling units
The WAGO Selection Tool is specifically designed to
A powerful tool to select the right Air Handling Units select the optimal WAGO I/O system for your needs.
for your needs.
›› 3D interface ›› Easy selection of WAGO materials
›› quick selection procedures ›› Material list creation
›› new print-out possibilities and report shapes ›› Time saving
• Includes wiring schemes
• Contains commissioning/preset data for

Plugins and third-party software tools


Building Information Modelling http://bimobject.
(BIM) support
com/en/
›› BIM improves efficiency of design and build phase
›› Daikin is among the first
product/
to supply a full library of BIM objects ?freetext=daikin
for its VRV products

Energy simulation and design aid tools


Psychrometrics diagram NEW

›› The Psychrometrics Diagram Viewer demonstrates


the changing properties of moist air.
›› With this tool, users can choose two points with
specific conditions, plot them on the diagram and
select actions to change the conditions, i.e. heat,
cool and mix air.
166
SKY AIR INTRO
Service tools
Error code app

INDOOR
UNITS
Quickly know the meaning of fault codes, for each
product family and the potential cause

D-Checker

D-checker is a software application used to record


and monitor operation data of Daikin applied, split,
Multi-split, Sky-air units, Daikin Altherma LT, ground

OUTDOOR
UNITS
source heat pump, Hybrid, ZEAS, Conveni-pack &
R410A Booster unit

Bluetooth adaptor NEW

Monitoring of Split, Sky Air and VRV data via any


bluetooth device Diagnosis of the Bluetooth system possible:

AIR CURTAINS
›› No need to access the outdoor unit

BIDDLE
• Connects with D-Checker software (for laptops)
• Connects with monitoring app (for tablets or
smartphones) Computer with Bluetooth

VENTILATION
Online support Internet
NEW Business portal Find our solution for different applications:
›› Experience our new extranet that

CONTROL
SYSTEMS
thinks with you at my.daikin.eu Supermarket Technical
Restaurant
›› Find information in seconds
via a powerful search Hotel Store & Bank Industry
shop
›› Customise the options so you
Sport &
see only info relevant for you Home Office Leisure
›› Access via mobile device or desktop

& ACCESSORIES
OPTIONS
my.daikin.eu
ON
THE ›› Get more commercial details on our flagship
R OA D products via our dedicated minisites
& PLATFORMS

AT
TOOLS

C U S TO M E ›› See our references


RS
TECHNICAL
DRAWINGS

AT THE OFFICE HOTEL PORTA FIRA

www.daikineurope.com/references
PREVIOUS

167
Europe’s
new energy label
Labelling to encourage intelligent choices
To enable consumers to compare and make The energy label includes multiple classifications
purchasing decisions based on uniform labelling from A+++ to D, reflected in colour shadings ranging
criteria, Europe has introduced energy labels. The from dark green (most energy efficient) to red (least
previous European energy label for air conditioners, efficient). Information on the label not only includes
introduced in 1992, did its job for the time. In 2013, the seasonal efficiency ratings for heating (SCOP) and
Europe introduced a seasonal energy label. This cooling (SEER), but also annual energy consumption
label allows end users to make even more informed and noise levels.
choices, since seasonal efficiency reflects air
conditioner efficiency over an entire season.

The label
more in detail

Name of manufacturer Combination of indoor


and product and outdoor unit

SEER: seasonal efficiency SCOP: seasonal efficiency


values for cooling values for heating

Classifications from A+++ Classifications from A+++


(most energy efficient) (most energy efficient)
to D (least energy efficient to D (least energy efficient)

Design load for cooling Design load for heating

Seasonal efficiency ratings Seasonal efficiency ratings


for cooling (SEER) for heating (SCOP)

Annual energy consumption Annual energy consumption


during a cooling season, during a heating season,
including auxiliary modes including auxiliary modes

Sound power value


for indoor unit

To take the broad range of


conditions into account,
Sound power value 3 climate zones are used:
for outdoor unit cold, average and warm

blue= colder climate (optional)


green= average climate (compulsory)
orange = warmer climate (optional)

168
SKY AIR INTRO
Measuring conditions

INDOOR
UNITS
Power supply Conversion table refrigerant piping
inch mm
T1 = 3~, 220V, 50Hz 1
/4˝ 6.4 mm
V1 = 1~, 220-240V, 50Hz 3
/8˝ 9.5 mm
VE = 1~, 220-240V/220V, 50Hz/60Hz* 1
/2˝ 12.7 mm
V3 = 1~, 230V, 50Hz 5
/8˝ 15.9 mm

OUTDOOR
UNITS
VM = 1~, 220~240V/220~230V, 50Hz/60Hz
3
/4˝ 19.1 mm
7
/8˝ 22.2 mm
W1 = 3N~, 400V, 50Hz 1 1/8˝ 28.5 mm
Y1 = 3~, 400V, 50Hz 1 3/8˝ 34.9 mm
1 5/8˝ 41.3 mm
1 3/4˝ 44.5 mm
2˝ 50.8 mm
2 1/8˝ 54 mm
* For VE power supply only 1~, 220-240V, 50Hz data 2 5/8˝ 66.7 mm

AIR CURTAINS
is displayed in this catalogue.

BIDDLE
F-gas regulation

VENTILATION
For fully/partially charged equipment: contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit
construction, details can be found on the unit labels.

For non pre-charged equipment (Chillers: split chiller (SEHVX/SERHQ), condensing units and condenserless chillers + refrigeration
(LCBKQ-AV1, JEHCCU/JEHSCU and ICU): Its functioning relies on fluorinated greenhouse gases.

CONTROL
SYSTEMS
Measuring conditions
Air conditioning

1) Nominal cooling capacities are based on:

& ACCESSORIES
Indoor temperature 27°CDB/19°CWB

OPTIONS
Outdoor temperature 35°CDB
Refrigerant piping length 7.5m - 8/5m VRV
Level difference 0m
2) Nominal heating capacities are based on:
Indoor temperature 20°CDB
Outdoor temperature 7°CDB/6°CWB
Refrigerant piping length 7.5m - 8/5m VRV
Level difference 0m
& PLATFORMS
TOOLS

The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value,
depending on the distance and acoustic environment (for measuring conditions: please refer to the technical databooks).
The sound power level is an absolute value indicating the “power” which a sound source generates.
For more detailed information please consult our technical databooks.
TECHNICAL
DRAWINGS
PREVIOUS

169
170
Indoor units
Outdoor units
Biddle air curtains
drawings

255
202
172
Technical

171
TECHNICAL TOOLS OPTIONS CONTROL BIDDLE OUTDOOR INDOOR
PREVIOUS VENTILATION SKY AIR INTRO
DRAWINGS & PLATFORMS & ACCESSORIES SYSTEMS AIR CURTAINS UNITS UNITS
Technical drawings

Indoor units
FCAG-A / FCAHG-G 173
FFA-A 175
FDXM-F3 177
FBA-A 180
FDA-A 185
FDQ-B 188
ABQ-C 190
FAA-A 192
FHA-A 193
AHQ-C 196
FUA-A 197
FVA-A 198
FNA-A 199

172
VIEW ALL FCAG-A TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FCAG-A / FCAHG-G WITH AUTO-CLEANING PANEL


FCQG35-71F
with auto-cleaning panel
300 or less
See note 5
Drain side

860 - 910 (ceiling opening see note 3)


121.6

INDOOR
UNITS
780 (suspension position)
121.6

25.4

25.4
121.6

96.5
Piping side DETAIL C
DETAIL B 2 PLACES
See note 6 2 PLACES OPPOSITE SIDE

OUTDOOR
710 (suspension position) OPPOSITE SIDE

UNITS
860 - 910 (ceiling opening, see note 3)
200mm 1500mm or more

Adjustable (0 - 675)
or more

1500mm or more
1500mm or
more
200mm
or more 1500mm or more
REQUIRED SPACE
(installation space)

In case a discharge opening is closed with the “sealing member” option, the
2500 or more

(See note 3) (See note 3) distance of 1500mm can be reduced to 500mm on the closed side.

AIR CURTAINS
External
surface Ventilator Other unit
Hanging bolt light

BIDDLE
4 x M8 - M10 VIEW A
1500 or
more
2000 or more
NOTE 4000 or more
Item Name
1. Location of the nameplates 1 Liquid pipe connection
- Unit body: on the control box cover 2 Gas pipe connection
- Decoration panel: on the panel frame at the piping side under the corner cover 3 Drain pipe connection
2. When installing an optional accessory, refer to the installation drawings. 4 Power supply entry hole
- For fresh air intake kit an inspection part is necessary 5 Transmission wiring entry hole
3. Make sure the spacing between the ceiling and the cassette is no more than 35mm. Max ceiling opening: 910mm 6 Air discharge opening
7 Air suction grille

VENTILATION
4. When the conditions exceed 30°C and RH 80% in the ceiling or fresh air is inducted into the ceiling, an additional insulation
is required (polyethylene foam, thickness 10mm or more) 8 Corner decoration cover
9 Drain hose
5. In case of using a sensor kit, this position will be a sensor, refer to the drawing of the sensor kit for more detail
10 Knock out hole
6. In case of using a infrared control, this position will be a receiver, refer to the drawing of the infrared control for more detail
Model
FCQG35-71FVEB, FXFQ20-63AVEB 2D090245A

FCAG-A / FCAHG-G WITH STANDARD PANEL


FCQG100-140F
with standard panel

CONTROL
SYSTEMS
300 or less
See note 5
Drain side
860 - 910 (ceiling opening see note 3)
780 (suspension position)

& ACCESSORIES
OPTIONS
Piping side DETAIL C
DETAIL B 2 PLACES
See note 6 2 PLACES OPPOSITE SIDE
710 (suspension position) OPPOSITE SIDE
860 - 910 (ceiling opening, see note 3) 1500mm or more
200mm
or more
1500mm or more
Adjustable (0 - 675)

1500mm or
& PLATFORMS

more 200mm
or more 1500mm or more
TOOLS

REQUIRED SPACE
(installation space)

In case a discharge opening is closed with the “sealing member” option, the
2500 or more

(See note 3) distance of 1500mm can be reduced to 500mm on the closed side.
(See note 3)
External Ventilator Other unit
surface
light
1500 or
more
Hanging bolt VIEW A 2000 or more
4 x M8 - M10 4000 or more

NOTE Item Name


1 Liquid pipe connection
1. Location of the nameplates 2 Gas pipe connection
TECHNICAL

3 Drain pipe connection


DRAWINGS

- Unit body: on the control box cover


4 Power supply entry hole
- Decoration panel: on the panel frame at the piping side under the corner cover 5 Transmission wiring entry hole
2. When installing an optional accessory, refer to the installation drawings. 6 Air discharge opening
- For fresh air intake kit an inspection part is necessary 7 Air suction grille
3. Make sure the spacing between the ceiling and the cassette is no more than 35mm. Max ceiling opening: 910mm 8 Corner decoration cover
4. When the conditions exceed 30°C and RH 80% in the ceiling or fresh air is inducted into the ceiling, an additional insulation 9 Drain hose
is required (polyethylene foam, thickness 10mm or more) 10 Knock out hole
5. In case of using a sensor kit, this position will be a sensor, refer to the drawing of the sensor kit for more detail
6. In case of using a infrared control, this position will be a receiver, refer to the drawing of the infrared control for more detail
Model
256 FCQG100-140FVEB, FXFQ80-100AVEB
298 FCQHG71-140FVEB, FXFQ125AVEB 3D077130E
PREVIOUS

173
VIEW ALL FCAG-A TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FCAG-A
FCAG-A/ FCAHG-G

55 840 55 Duct
Left side

Piping side
See note 3.

427
140

328
130

Static pressure in chamber [Pa]


120
110
840

100
90
80

328
70

427
60
50
Drain side See note 3. 40
30
20
10

0 1 2 3 4 5 6
Duct
448
Right side View A Air flow rate [m³/min]
508

Service access panel


450 x 450 mm or more
148

See note 1. (1000)


AA

275
165

Suction chamber 455

FCAG-A/ FCAHG-G
Ceiling opening
Decoration panel
725 T-joint
A Field supply

Notes Inlet

1. When installing a fresh air intake kit, provide a service access panel.
2. Field construction
3. This corner discharge outlet needs to be closed.
4. When installing a duct fan, use a wiring adapter to link the duct fan to the fan of the indoor unit. Sensor kit Installation methods
5. The intake air flow rate is recommended to be ≤20% of the air flow rate at high fan speed.
If the intake air flow rate is too large, the operating sound may increase, and the detection of the indoor unit suction temperature may be affected.
6. This indicates the distance between the T-joint inlet and the indoor unit inlet when the T-tube is connected. Sensor kit Drain side

3D106327
FCAG-A
Piping side
Decoration panel

Sensor kit BRYQ140A7

FCAG-A/ FCAHG-G Decoration panel BYCQ140D7W1(W)

Sensor kit Installation methods


Sensor kit Drain side

Sensor kit Installation methods

Sensor kit Drain side

Decoration panel Piping side

Piping side
Decoration panel

Sensor kit BRYQ140A7 Sensor kit BRYQ140A7


Decoration panel BYCQ140D7W1(W)
Decoration panel BYCQ140D7GW9/BYCQ140D7GFW9
Sensor kit Installation methods
Sensor kit Drain side

4D106294

Decoration panel Piping side

174
VIEW ALL FFA-A TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FFA25-35A - FULLY FLAT PANEL


FFA25-35A ・DECORATION PANEL

BYFQ60C2W1W FRESH WHITE N9.5


BYFQ60C2W1S DAIKIN SILVER
620 585∼ 595 (CELING OPENING SPACE) 223
300 OR LESS 533 (SUSPENSION POSITION) 89

INDOOR
UNITS
Service Access Panel 320
PIPE CONNECTION

89
450 x 450mm ore more
SIDE

Ø1
00

585∼ 595 (CELING OPENING SPACE)



150
533 (SUSPENSION POSITION)
620


4-M4 HOLE
OUTDOOR AIR INTAKE
(DIRECT CONNECTION)

B ARROW VIEW
DRAIN CONNECTION
SIDE

・REQUIRED SPACE

OUTDOOR
NOTE)2.
A ARROW VIEW 1500mm OR MORE

UNITS
320 1500mm


345 OR MORE
1500mm
590 OR MORE

3 1
1500mm OR MORE
ADJUSTABLE(0∼630)

WHEN THE DISCHARGE GRILL IS CLOSEOUT,


22 575 22 22 575 22   THE REQUIRED SPACE IS 200mm OR MORE.


196 63
C ARROW VIEW
850

AIR CURTAINS
300 OR MORE

BIDDLE
260

298
220

(190)
194


156
38
46

FOR HEIGHT INSTALLATION


(REQUIRED SPACE)
8

1500 OR MORE
172 10 OR LESS 10 OR LESS

FROM THE FLOOR SIDE


NOTE)4.
SUSPENSION BOLT 211
4-M8∼M10

2500 OR MORE
NOTE) 1. STICKING LOCATION FOR MANUFACTURE'S LABEL
MANUFACTURE'S LABEL FOR INDOOR UNIT:ON THE BELL MOUTH INSIDE SUCTION GRILLE
MANUFACTURE'S LABEL FOR DECORATION PANEL :ON THE INNER FRAME INSIDE SUCTION GRILLE
2. IN CASE OF USING WIRELESS REMOTE CONTROLLER ,THIS POSITION WILL BE A SIGNAL RECEIVER.

VENTILATION
REFER TO THE DRAWING OF WIRELESS REMOTE CONTROLLER IN DETAIL.
3. WHEN THE TEMPERATURE AND HUMIDITY IN THE CEILING EXCEED 30 AND RH 80% OR THE FRESH AIR ITEM PART NAME REMARK ITEM PART NAME REMARK
IS INDUCTED INTO THE CEILING OR THE UNIT CONTINUES 24 HOUR OPERATION,AN ADDITIONAL 1 LIQUID PIPE CONNECTION φ6.4(FRARE 5 REMOTE CONTROL CODE
CONNECTION) AND CONTROL WIRING
INSULATION (THICKNESS 10mm OR MORE OF GLASSWOOL OR POLYETHYLENE FORM) IS REQUIRED. CONNECTION
2 φ9.5(FRARE
4. THOUGH THE INSTALLATION IS ACCEPTABLE UP TO MAXIMUM OF 595mm SQUARE CEILING OPENING, GAS PIPE CONNECTION
CONNECTION) 6 AIR DISCHARGE GRILL
KEEP THE CLEARANCE OF 10mm OR LESS BETWEEN THE MAIN UNIT AND THE CEILING OPENING SO THAT 3 DRAIN PIPE CONNECTION VP20(O.D.φ26) 7 SUCTION GRILL

3D082433
THE PANEL OVERLAP ALLOWANCE CAN BE ENSURED. 4 POWER SUPPLY CONNECTION 8 DRAIN HOSE(ACCESSORY) I.D.φ25(OUTLET)

FFA25-35A - STANDARD PANEL

CONTROL
SYSTEMS
FFA25-35A
Decoration panel

BYFQ60B2W1 WHITE Ral 9010


BYFQ60B3W1 WHITE Ral 9010 Ceiling opening
700 585∼ 660
Note ) 2. 300 or less
533 Suspension position
210
89
320
Piping side
89

Service access panel

& ACCESSORIES
450 x 450mm or more
Ø1

OPTIONS
00
150


Ceiling opening
Suspension position
700

6 8 4-M4 Hole Outdoor air intake (direct connection)

View B ARROW
585∼ 660

Drain side
533

Required space
1500mm or more

View A ARROW 320 1500mm or more

5 345
1500mm or more
& PLATFORMS

590
3 1 1500mm or more
TOOLS
Adjustable (0∼645)

When closing the air outlet, the required space is 200mm or more.
62.5 575 62.5
196 2 63
View C ARROW
850

295 or more


260

285
205

183

(180)


145
25
30
55

45 or less 45 or less
172
1500 or more

TECHNICAL
DRAWINGS

Suspension bolt Note ) 4.


211
4-M8∼M10
Required space

Ceiling height

62.5 575 62.5


2500 or more


Note )
To floor

1. Location of nameplate
The indoor unit nameplate is located on the bell mouth inside the suction grille.
The decoration panel nameplate is located on the inner frame inside the suction grille.

2. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller.
Item Part name Remark Item Remark
3. If any of the following conditions are met, additional insulation (glass wool or polyethylene foam, thickness ≥10mm) is required: φ6.4 Remote control wiring
1 Liquid pipe connection _ 5
Flare connection intake
Ambient conditions in the ceiling ≥ 30°C and 80% relative humidity. _________ φ9.5
2 Gas pipe connection __ Flare connection 6 Air discharge grille
Fresh air is inducted into the ceiling. The unit operates continuously.
________
3 Drain pipe connection VP20(O.D φ26 ) 7 Air suction grille
4. Though the installation is acceptable up to maximum 660mm square ceiling opening, keep the clearance of 45mm or less 4 Power supply 8 Drain hose Accessory I.D.φ25 Outlet
between the indoor unit and the ceiling opening, so that the panel overlap allowance can be ensured.

3D082434C
PREVIOUS

175
VIEW ALL FFA-A TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FFA50-60A - FULLY FLAT PANEL


・DECORATION PANEL
FFA50-60A
BYFQ60C2W1W FRESH WHITE N9.5
BYFQ60C2W1S DAIKIN SILVER

620 585∼ 595 (CELING OPENING SPACE) 223


300 OR LESS 533 (SUSPENSION POSITION) 89

320
Service Access Panel
PIPE CONNECTION

89
SIDE
450 x 450mm ore more

Ø1

585∼ 595 (CELING OPENING SPACE)


00

150
533 (SUSPENSION POSITION)
620


4-M4 HOLE
OUTDOOR AIR INTAKE
(DIRECT CONNECTION)

B ARROW VIEW
DRAIN CONNECTION
SIDE

・REQUIRED SPACE
NOTE)2.
A ARROW VIEW 1500mm OR MORE

320
1500mm
345
5 1500mm OR MORE
590 OR MORE

3 1
1500mm OR MORE
ADJUSTABLE(0∼630)

WHEN THE DISCHARGE GRILL IS CLOSEOUT,


22 575 22 22 575 22   THE REQUIRED SPACE IS 200mm OR MORE.


196 63
C ARROW VIEW
850

300 OR MORE

260

298
220

194

190

156
38
46

FOR HEIGHT INSTALLATION


(REQUIRED SPACE)
1500 OR MORE
8

172 10 OR LESS 10 OR LESS

FROM THE FLOOR SIDE


2500 OR MORE
NOTE)4.
SUSPENSION BOLT 211
4-M8∼M10

NOTE) 1.STICKING LOCATION FOR MANUFACTURE'S LABEL


MANUFACTURE'S LABEL FOR INDOOR UNIT:ON THEBELL MOUTH INSIDE SUCTION GRILLE
MANUFACTURE'S LABEL FOR DECORATION PANEL :ON THE INNER FRAME INSIDE SUCTION GRILLE
2.IN CASE OF USING WIRELESS REMOTE CONTROLLER,THIS POSITION WILL BE A SIGNAL RECEIVER.
REFER TO THE DRAWING OF WIRELESS REMOTE CONTROLLER IN DETAIL. ITEM PART NAME REMARK ITEM PART NAME REMARK
3.WHEN THE TEMPERATURE AND HUMIDITY IN THE CEILING EXCEED 30 AND RH 80% OR THE FRESH AIR REMOTE CONTROL CODE
IS INDUCTED INTO THE CEILING OR THE UNIT CONTINUES 24 HOUR OPERATION,AN ADDITIONAL 1 LIQUID PIPE CONNECTION φ6.4(FRARE
5 AND CONTROL WIRING
CONNECTION)
INSULATION (THICKNESS 10mm OR MORE OF GLASSWOOL OR POLYETHYLENE FORM) IS REQUIRED. φ12.7(FRARE CONNECTION
4 GAS PIPE CONNECTION 6 AIR DISCHARGE GRILL
4.THOUGH THE INSTALLATION IS ACCEPTABLE UP TO MAXIMUM OF 595mm SQUARE CEILING OPENING, CONNECTION)
KEEP THE CLEARANCE OF 10mm OR LESS BETWEEN THE MAIN UNIT AND THE CEILING OPENING SO THAT 3 DRAIN PIPE CONNECTION VP20(O.D.φ26) 7 SUCTION GRILL

3D082052
THE PANEL OVERLAP ALLOWANCE CAN BE ENSURED. 4 POWER SUPPLY CONNECTION 8 DRAIN HOSE(ACCESSORY) I.D.φ25(OUTLET)

FFA50-60A - STANDARD PANEL


FFA50-60A
Decoration panel
BYFQ60B2W1 WHITE Ral 9010
BYFQ60B3W1 WHITE Ral 9010
Ceiling opening
700 585∼ 660
300 or less
533
210
Note ) 2. 89
Suspension position
320
Piping side Service access panel
89

450 x 450mm or more


Ø1
00
150


31

Suspension position

Ceiling opening
700

6 8 4-M4Hole
Outdoor air intake (direct connection)

View B ARROW
585∼ 660

Drain side
533

Required space
1500mm or more 1500mm or more

View A ARROW 320


5 345
1500mm or more
590
3 1
1500mm or more
When closing the air outlet, the required space is 200mm or more.
62.5 575 62.5
(0∼645)

196 2 63
Adjustable

View C ARROW
850

295 or more


260

285
205

183

(180)


145
25
30
55

45 or less 45 or less
172
1500 or more

Required space

Suspension position Note ) 4.


2500 or more

211
4-M8∼M10
62.5 575 62.5

Ceiling height
To floor

Note )
1. Location of nameplate Item Part name Remark Item Part name Remark
The indoor unit nameplate is located on the bell mouth inside the suction grille.
φ6.4
The decoration panel nameplate is located on the inner frame inside the suction grille. 1 Liquid pipe connection 5
2. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller. Flare connection
3. If any of the following conditions are met, additional insulation (glass wool or polyethylene foam,thickness ≥10mm) is required: 2 Gas pipe connection φ12.7
6 Air discharge grille
Ambient conditions in the ceiling ≥ 30°C and 80% relative humidity. Flare connection
Fresh air is inducted into the ceiling. The unit operates continuously. 3 Drain pipe connection VP20(O.D. φ 26) 7 Air suction grille
4 Power supply 8 Drain hose Accessory

3D082161C
4. Though the installation is acceptable up to maximum 660mm square ceiling opening, keep the clearance of 45mm or less bet I.D.φ25 Outlet
ween the indoor unit and the ceiling opening, so that the panel overlap allowance can be ensured.

176
VIEW ALL FDXM-F TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FDXM25-35F3
FDXM25-35F3 750 300 O R MORE 620
(SERVICE SPACE)

20 O R M O R E

300
(SUSPENSION BOLT P I T C H )
400 O R M O R E

20 O R M O R E

240 O R M O R E
(IN CASE OF

BOTTOM SUCTION)

INDOOR
UNITS
620

500

750
A CEILING

60
SERVICE SPA C E
16x 1/4.7 HOLE
VIEW A
INSPECTION DOOR
5x P100=5 0 0 (CEILING OPENING)
8 740
(SUSPENSION BOLT PITCH)

SUSPENSION BOLT

OUTDOOR
4x M8 ~ M10 680 1

UNITS
2
660
4x P150=6 0 0
12.5

130 63
57.5

16x M5 HOLES
21

20
10
310

50

50
47
90

170
9
170
153

100

100
160
180
200

80

23

30 330 140 5x P100=5 0 0

14x M4 HOLES 101 580


90 600
4 35
7 80 620

AIR CURTAINS
IN CASE OF BACK SUCTION

BIDDLE
NOTES:

9 1. IN CASE OF BACK SUCTION,


MOUNT CHAMBER COVER TO BOTTOM SIDE OF THE UNI T .
IN C A S E O F BOTTOM SUCTION,
6 MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT.
2. L O C A T I O N O F UNIT NAME PLATE: CONTROL BOX COVER.
3. MOUNT TH E AIR FILTER AT THE SUCTION SIDE.
(USE AN AIR FILTER WHOSE DUST COLLECTING EFFICIENCY
IS AT L E A S T 5 0%
ITEM NAME DESCRIPTION IN A GRAVIMETRIC TECHNIQUE).
180

100
160
200

1 LIQUID PIPE CONNECTION 1/6,4 FLARE CONNECTION IT CAN NOT BE EQUIPPED WITH AIR FILTER (ACCESSOR Y )
2 GAS PIPE CONNECTION 1/9,5 FLARE CONNECTION WHEN CONNECTING DUCT TO SUCTION SIDE.
3 SOCKET FOR DRAIN VP20(OD 1/26, ID 1/20)
5x P100=5 0 0
10

4 DRAIN HOSE (ACCESSORY )


20

140 50 ID1/25 (OUTLET)


50

5 CONTROL BOX .

VENTILATION
580 100
6 TRANSMISSION WIRING .
16x M5 HOLES 600 90 7 POWER SUPPLY CONNECTION .
620 80 8 SUSPENSION BRACKET .

3D081343
9 AIR FILTER (ACCESSORY) .
IN CASE OF BOTTOM S U C T I O N

FDXM50-60F3
FDXM50-60F3

CONTROL
SYSTEMS
1150 300 OR MORE 620
300

(SERVICE SPACE)
(SUSPENSION BOLT PITCH)

240 O R M O R E
20 O R M O R E

400 O R M O R E
620

500

20 O R M O R E

(IN CASE OF
BOTTOM SUCTION)
1150

& ACCESSORIES
60

OPTIONS
10x P100 = 1000
26xø 4,7
1140 VIEW A
(SUSPENSION BOLT PITCH) A INSPECTION
(CEILING DOOR
OPENING)
SUSPENSION CEILING
4x M8 ~ M10 BOLT
SERVICE SPACE
1080
1060 1
2
6x P150=9 0 0
12.5

130 63
50
57.5
21

20
10

310
50
90
100 47

170
170
153

100
160
180
200

80

23

& PLATFORMS

30 330 150 9x P100=9 0 0


18xØM4
100 980
TOOLS

4 3 5 9
7 90 1000
80 1020
9
24x M5 IN CASE OF BACK SUCTION

NOTES

1. IN CASE OF BACK SUCTION,


MOUNT CHAMBER COVER TO BOTTOM SIDE OF THE UNIT.
IN CASE OF BOTTOM SUCTION,
160
180

100
200

MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT.


6 2. LOCATION OF UNIT NAME PLATE: CONTROL BOX COVER.
9x P100=9 0 0 3. MOUNT THE AIR FILTER AT THE SUCTION SIDE.
130 50 (USE AN AIR FILTER WHOSE DUST COLLECTING EFFICIENCY IS AT LEAST 50%
10

50
20

980 100 IN A GRAVIMETRIC TECHNIQUE).


TECHNICAL

IT CAN NOT BE EQUIPPED WITH AIR FILTER (ACCESSORY)


DRAWINGS

1000 90 WHEN CONNECTING DUCT TO SUCTION SIDE.


1020 80 ITEM NAME DESCRIPTION
1 LIQUID PIPE CONNECTION 1/6.4 FLARE CONNECTION
IN CASE OF BOTTOM SUCTION 2 GAS PIPE CONNECTION
SOCKET FOR DRAIN
1/12.7 FLARE CONNECTION
VP20 (OD 1/26, ID 1/20)
3
4 DRAIN HOSE (ACCESSORY) ID 1/25 (OUTLET)
5 CONTROL BOX .
6 TRANSMISSION WIRING .
7 POWER SUPPLY CONNECTION .
8 SUSPENSION BRACKET .
9 AIR FILTER (ACCESSORY) .

3D081360
PREVIOUS

177
VIEW ALL FDXM-F TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FDXM25-35F3
FDXM25-35F3

(mmH2 O) (mmH2 O)
7 70 7

6 60 6

5 50 5
External static pressure [Pa]

40 SP
fE
4 4
it o
lim
er
p
Up

3 30 3

2 20 2

1 10 1

SL

(PA)
(mmH2 O) 5 6 7 8 9 10 11 (mmH2 O)
Air flow rate [m³/min]

3D081327C
FDXM50F3
FDXM50F3

(mmH2 O) (mmH2 O)
70
7 7

6 60 6

5 50 5
External static pressure [Pa]

4 40 4
H

3 30 3

2 20 2
ESP
it of
er lim
Low
SL

1 10 1

(PA)
(mmH2 O) 9.5 10.5 11.5 12.5 13.5 14.5 15.5 16.5 17.5 (mmH2 O)
Air flow rate [m³/min]

3D085960C

178
VIEW ALL FDXM-F TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
FDXM60F3
FDXM60F3

(mmH2O)
(mmH2O)

INDOOR
70
7 7

UNITS
6 60 6

5 50 5
SP
fE
mit o
r li
External static pressure [Pa]

pe

OUTDOOR
Up

UNITS
4 40 4
H

3 30 3

2 20 SP
2
it of E
er lim
Lowe

AIR CURTAINS
SL

BIDDLE
1 10 1

[PA]
(mmH2O) 9.5 10.5 11.5 12.5 13.5 14.5 15.5 16.5 17.5 (mmH2O)
Air flow rate [m³/h]

VENTILATION
3D081329C

CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

179
VIEW ALL FBA-A TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
FBA35A
FBA35A

170 Ø 100 Suspension bolt 700 69


(Knockout hole.) 25 800

Service space
300 or more
492 40
Fresh air intake position 301

2x65=130
50 KJ KC KE KH

109
100
65

38
140

178
245

110
210
ARROW VIEW A
KK
126 P.C.D. 3x140=420 32 KF 179 50

50
KD
515 500 or more
4-M4 (CLASS 2)
Service space 654
4x145=590
738 Suspension position
6x65=390

KA

210
95
KB

630 Suspension position


ARROW VIEW A KG

42 155 130 130 120 5-Ø4.7 HOLE

Item Name Description


KA Liquid pipe connection port Ø6.35 flared connection
KB Gas pipe connection port Ø9.52 flared connection
KC Drain pipe connection VP20 (OD Ø26, ID Ø20)
KD Wiring connection /
KE Power supply connection /
KF Drain outlet VP20 (OD Ø26, ID Ø20)
KG Air filter /
KH Air suction side /
KJ Air discharge side /
KK Nameplate /
Notes
1.When installing optional accessories, refer to their respective documentation.
2.The ceiling depth varies according to the documentation of the specific system.

3D094988B
FBA50A
FBA50A

170 Ø 100 Suspension bolt 700 69


(Knockout hole.) 25 800

Service space
300 or more
492 40
2x65=130

Fresh air intake position 301


50 KJ KC KE KH
109
100
65

38
140

178
245

110
210

ARROW VIEW A
KK
126 P.C.D. 3x140=420 32 KF 179 50
50

KD
515 500 or more
4-M4 (CLASS 2) Service space 654
4x145=590
738 Suspension position
6x65=390

KA
210
95

KB
630 Suspension position

ARROW VIEW A KG

42 155 130 130 120 5-Ø4.7 HOLE

Item Name Description Notes


1. When installing optional accessories, refer to their respective documentation.
KA Liquid pipe connection port Ø6.35 flared connection 2. The ceiling depth varies according to the documentation of the specific system.

KB Gas pipe connection port Ø12.70 flared connection


KC Drain pipe connection VP20 (OD Ø26, ID Ø20)
KD Wiring connection /
KE Power supply connection /
KF Drain outlet VP20 (OD Ø26, ID Ø20)
KG Air filter /
KH Air suction side /
KJ Air discharge side /
KK
Nameplate /
3D094918B

180
VIEW ALL FBA-A TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FBA60A
FBA60A

170 Ø100 Suspension bolt 1000 69 25 800


(Knockout hole.)
792 40

Service space
301

300 or more

INDOOR
UNITS
2x65=130
Fresh air intake position 50 KC KE KH
KJ

109
38
100
65
140

178

110
210
245
ARROW VIEW A
KK

50
126 P.C.D. 5x146=730 32 179 50
KF KD
4 x M4 (CLASS 2) 815 500 or more
Service space

954
1038 Suspension position
6x145=890
11x65=715

OUTDOOR
UNITS
210
95
KA

KB
KG ARROW VIEW A KG
630 Suspension position

AIR CURTAINS
BIDDLE
42 135 125 98 117 135 125 100 8-Ø4.7 HOLE

Item Name Description


KA Liquid pipe connection port Ø6.35 flared connection
KB Gas pipe connection port Ø12.70 flared connection Notes
1. When installing optional accessories, refer to their respective documentation.
KC Drain pipe connection VP20 (OD Ø26, ID Ø20) 2. The ceiling depth varies according to the documentation of the specific system.

KD Wiring connection /
KE Power supply connection /
KF Drain outlet VP20 (OD Ø26, ID Ø20)
/

VENTILATION
KG Air filter
KH Air suction side /
KJ Air discharge side /
KK Nameplate /
3D094983B
FBA71A

FBA71A

CONTROL
SYSTEMS
170 Ø100 Suspension bolt 1000 69 25 800
(Knockout hole.)
792 40

Service space
301

300 or more
2x65=130

Fresh air intake position 50 KC KE KH


KJ
109
38
100
65
140

178

110
210
245

& ACCESSORIES
ARROW VIEW A
KK

OPTIONS
50

126 P.C.D. 5x146=730 32 179 50


KF KD
4 x M4 (CLASS 2) 815 500 or more
Service space

954
1038 Suspension position
6x145=890
11x65=715
210
95

KA

KB
KG ARROW VIEW A KG
630 Suspension position

& PLATFORMS
TOOLS

42 135 125 98 117 135 125 100 8-Ø4.7 HOLE

Item Name Description


Notes
KA Liquid pipe connection port Ø9.52 flared connection 1. When installing optional accessories, refer to their respective documentation.
2. The ceiling depth varies according to the documentation of the specific system.
KB Gas pipe connection port Ø15.90 flared connection
TECHNICAL
DRAWINGS

KC Drain pipe connection VP20 (OD Ø26, ID Ø20)


KD Wiring connection /
KE Power supply connection /
KF Drain outlet VP20 (OD Ø26, ID Ø20)
KG Air filter /
KH Air suction side /
KJ Air discharge side /
KK Nameplate /
3D094915B
PREVIOUS

181
VIEW ALL FBA-A TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FBA100-140A
FBA100-140A
170 Ø100 Suspension bolt 1400 69 25 800

Service space
300 or more
(Knockout hole.)
1192 40 301
KC

2x65=130
Fresh air intake position KJ KE KH
50

109
38
100
65
140

178

110
210
245
ARROW VIEW A
KK
126 P.C.D. 7x156=1092 32 179 50

50
KF
1215 500 or more KD
4 x M4 (CLASS 2)
Service space

1354
1438 Suspension position 8X150=1200
16x65=1040

226
95
KA

KB KG
KG ARROW VIEW A
630 Suspension position

42 150 147.5 147.5 115 115 150 147.5 147.5 115 10xØ4.7 HOLE

Item Name Description


KA Liquid pipe connection port Ø9.52 flared connection Notes
1. When installing optional accessories, refer to their respective documentation.
2. The ceiling depth varies according to the documentation of the specific system.
KB Gas pipe connection port Ø15.90 flared connection
KC Drain pipe connection VP20 (OD Ø26, ID Ø20)
KD Wiring connection /
KE Power supply connection /
KF Drain outlet VP20 (OD Ø26, ID Ø20)
KG Air filter /
KH Air suction side /
KJ Air discharge side /
KK Nameplate /
3D094914B

FBA35-50A
FBA35-50A
200
200

Fan characteris�cs (1)


Fan characteris�cs (3)
Air flow auto adjustment

H-Tap *1

150 150

1.
*1 Upper limit of ESP
Lower limit of ESP
*1
M-Tap *1
Upper limit of ESP
100 H-Tap *2 100

L-Tap *1 H-Tap

M-Tap *2 M-Tap
*2 *2
Upper limit of ESP Lower limit of ESP
50
L-Tap *2
50
L-Tap
*3
H-Tap *3
Upper limit of ESP 2.

M-Tap *3
*3 Lower limit of ESP
L-Tap *3 Lower limit of ESP
0
0 13 14 15 16 17
9 10 11 12
9 10 11 12 13 14 15 16 17

Air flow rate [m³/min] Air flow rate [m³/min]


Mark ESP [Pa]
*1 MAX 150
*2 - 100
30
1. Upper limit of ESP by air flow auto adjustment
*3 STD
2. Lower limit of ESP by air flow auto adjustment
Fan characteris�cs (2)
Field se�ng with remote control

200

190 Air flow rate range (H)


180

170

160

150

140

130

120
External sta�cpressure[Pa]

110

100

90

80

70

60

50

40

30

20

10

0
13 14 15 16 17

Air flow rate [m³/ m i n ]

Notes:
1. The fan characteristics shown are in "fan only" mode.

3D095521B
2. ESP: External static pressure.

182
VIEW ALL FBA-A TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FBA60-71A
FBA60-71A
200
200

Fan characteris�cs( 1 ) Fan characteris�cs (3)


Air flow auto adjustment

H-Tap *1
150

150 1.

INDOOR
Upper limit of ESP

UNITS
*1
Lower limit of ESP

*1 100

Upper limit of ESP H-Tap *2


100

H-Tap

L-Tap *1 M-Tap
M-Tap *2
*2
Lower limit of ESP
*2 50 L-Tap
Upper limit of ESP
50
L-Tap *2 2.
*3 H-Tap *3
Upper limit of ESP

OUTDOOR
M-Tap *3 Lower limit of ESP
L-Tap *3

UNITS
0
10.5 11.5 12.5 13.5 14.5 15.5 16.5 17.5 18.5 19.5 20.5
*3
Lower limit of ESP
0
10.5 11.5 12.5 13.5 14.5 15.5 16.5 17.5 18.5 19.5 20.5

Air flow rate [m³/min]


Air flow rate [m³/min]
Mark ESP [Pa] 1. Upper limit of ESP by air flow auto adjustment
*1 MAX 150 2. Lower limit of ESP by air flow auto adjustment
*2 - 100

*3 STD 30

Fan characteris�cs(2)
Field set�ng with remote control

200

190
Air flow rate range (H)

AIR CURTAINS
180

170

160

BIDDLE
150

140

130

120

110

100
External sta�cpressure[Pa]

90

80

70

60

50

40

30

20

10

0
15.5 16.5 17.5 18.5 19.5 20.5

VENTILATION
Air flow rate [m³/min]

3D095524B
Notes:
1. Fan characteristics as shown are in "fan only" mod e .
2. ESP: External static pressure.

FBA100A
FBA100A

CONTROL
SYSTEMS
200

Fan characteris�cs (1) 200

Fan characteris�cs (3)


Air flow auto adjustment

H-Tap *1
150
150

Upper limit of ESP 1.


*1
External sta�c pressure [Pa]

*1 Lower limit of ESP


M-Tap *1
External static pressure [Pa]

Upper limit of ESP

& ACCESSORIES
100
100
H-Tap *2

OPTIONS
H-Tap

L-Tap *1 M-Tap
M-Tap *2
*2 *2
Upper limit of ESP Lower limit of ESP 50
L-Tap
50 L-Tap *2 2.
*3 H-Tap *3
Upper limit of ESP
M-Tap *3
Lower limit of ESP
L-Tap *3
*3
0
Lower limit of ESP 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33

0
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
& PLATFORMS

Air flow rate [m³/min] Air flow rate [m³/min]


1. Upper limit of ESP by air flow auto adjustment
TOOLS

Mark ESP [Pa]


*1 MAX 150 2. Lower limit of ESP by air flow auto adjustment
*2 - 100
*3 STD 40

Fan characteris�cs (2)


Field se�ng with remote control

200

190 Air flow rate range (H)


180

170

160

150

140
External static pressure [Pa]

130

120
TECHNICAL
DRAWINGS

110

100

90

80

70

60

50

40

30

20

10

0
24.5 25.5 26.5 27.5 28.5 29.5 30.5 31.5 32.5 33.5

Air flow rate [m³/min]

3D095526B
PREVIOUS

Notes:
1. Fan characteristics as shown are in "fan only" mode.
2. ESP: External static pressure.

183
VIEW ALL FBA-A TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FBA125-140A
FBA125-140A
200
200

Fan characteris�cs (1) Fan characteris�cs (3)


Air flow auto adjustment

H-Tap *1

150 150

1.
Upper limit of ESP

M-Tap *1 *1
*1
Lower limit of ESP
Upper limit of ESP H-Tap *2
External sta�c pressure [Pa]

External sta�c pressure [Pa]


100
100

H-Tap
L-Tap *1
M-Tap *2 *2
Lower limit of ESP M-Tap
*2
Upper limit of ESP L-Tap 2.
L-Tap *2 50
50
H-Tap *3
*3 M-Tap *3 Lower limit of ESP
Upper limit of ESP
L-Tap *3
*3
Lower limit of ESP 0
20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
0
20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39

Air flow rate [m³/ m i n ] Air flow rate [m³/ m i n ]

Mark ESP [Pa]


*1 MAX 150
*2
*3
-
STD
100
50
1. Upper limit of ESP by air flow auto adjustment
2. Lowerl i m i t o f E S P b y a i r flow auto adjustment
Fan characteris�cs (2)
Field setting with remote control

200

190 Air flow rate range (H)


180

170

160

150

140
External sta�c pressure [Pa]

130

120

110

100

90

80

70

60

50

40

30

20

10

0
29 30 31 32 33 34 35 36 37 38 39

Air flow rate [m³/ m i n ]

Notes:

1. Fan characteristics as shown are in "fan only" m o d e .


2. ESP: External static pressure. 3D095527B

184
VIEW ALL FDA-A TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FDA125A
FDQ125C

(Knock out hole)


Fresh air intake position Suspension bolt

INDOOR
UNITS
(Service space)
350 or more
500 or more Detail B
(On circumference)
(Service space)

(Suspension position)
(Service space)

OUTDOOR
390 or more

UNITS
(Suspension position)

View A-A Detail B

Item Name Description


Liquid pipe connection Ø 9.52 Flare connection
(Ceiling opening) Gas pipe connection Ø 15.90 Flare connection
Drain pipe connection VP25 (O.D. Ø32, I.D. Ø 25)

AIR CURTAINS
Remote controller wiring connection
Power supply connection

BIDDLE
Drain hole VP25 (O.D. Ø32, I.D. Ø 25)
Air filter
Air suction side
Air discharge side
(Ceiling opening)

Nameplate

NOTES
1 Refer to the outlook drawing of optional accessories when installing them.
2 The required ceiling depth varies according to the configuration

VENTILATION
of the specific system.
3 For maintenance of the air filter, it is neœssary to provide a service access panel.
4 Optional decoration panel: BYB5125DJW1 (light ivory white 1OY9/0.5)

With decoration panel

FDA125A

CONTROL
SYSTEMS
FDQ125C
or less

& ACCESSORIES
OPTIONS
& PLATFORMS

Installation without air inlet duct Installation with air inlet duct
TOOLS

Number Description
Suspended ceiling
Ceiling openinq
Service access panel (optional)
TECHNICAL
DRAWINGS

Air filter
Air inlet duct
Duct service opening

NOTES
1 When installing the unit with rear suction, a service opening is necessary for the maintenance of the air filters.
2 When installing the unit with a suction duct, a service opening must be provided in the duct.
PREVIOUS

185
VIEW ALL FDA-A TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FDA-A
FDQ125C
Fan characteristics (1)

H (max. ESP)

Upper limit of external static pressure


(max. ESP)
Externalstatic pressure [Pa]

M (max. ESP)

Lower limit of external


static pressure (max. ESP)
L (max. ESP)

Upper limit of external H (Standard ESP)


static pressure
(max. ESP)
M (Standard ESP)
Lower limit of external static pressure
L (Standard ESP) (Standard ESP)

Airflow [m3/min]

NOTES
1. The fan characteristics shown are in "fan only" mode.
2. ESP: External Static Pressure

FDA-A

FDQ125C Fan characteristics (2)


(Field setting with remote controller)
range of available air flow rate (H)
Externalstatic pressure [Pa]

Airflow [m3/min]

NOTES
1. The fan characteristics shown are in "fan only" mode.
2. ESP: External Static Pressure

186
VIEW ALL FDA-A TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FDA-A

FDQ125C Fan characteristics (3)


(air flow auto adjustment )

INDOOR
UNITS
Upper limit of external static presure

Upper limit of ESP by airflow auto adjustment


Externalstatic pressure [Pa]

OUTDOOR
H

UNITS
M

Lower limit of ESP by airflow auto adjustment


L

AIR CURTAINS
BIDDLE
Airflow [m3/min]

VENTILATION
NOTES
1. The fan characteristics shown are in "fan only" mode.
2. ESP: External Static Pressure

CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

187
VIEW ALL FDQ-B TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FDQ200-250B

FDQ200-250B unit(mm)

FDYP200-250B

View A

View A

1) Power supply intake


2) Drain connection fi 250 O.D.
3) Gas pipe connection Notes
FDYP200B/250B:1 1/8" O.D. OR 28,6MM : Service space
FDQ200/250: 7/8" O.D. OR 22,2MM O.D.
4) Liquid pipe connection Model
FDDYP200B: single union joint 1/2" or 12,7mm FDYP200B8V19/FDQ200B8V3B9 830 285
FDYP250B: single union joint 5/8" or 15,9mm FDYP250B8V19/FDQ250B8V3B9 890 255
FDQ200: single union joint 3/8" or 9,52mm
FDQ250: single union joint 1/2" or 12,7mm
5)Filter
3TW30844-1

FDQ200B7

Fan curve FDQ200B7

high

medium
low

3TW22818-1

188
FDQ200B7

Fan curve FDQ250B7


VIEW ALL FDQ-B TECHNICAL
DRAWINGS ON MY.DAIKIN.EU

medium
high

3TW22828-1

189
Detailed technical drawings

TECHNICAL TOOLS OPTIONS CONTROL BIDDLE OUTDOOR INDOOR


PREVIOUS VENTILATION SKY AIR INTRO
DRAWINGS & PLATFORMS & ACCESSORIES SYSTEMS AIR CURTAINS UNITS UNITS
VIEW ALL ABQ-C TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

ABQ71C

ABQ71C

All dimensions are in mm

Dimension
Model A B C D E F G H I J K L M N P Q
ABQ71C 372 1001 959 920 410 285 600 339 121 231 54 100 245 216 824 869

ABQ100-140C
ABQ100-140C

All dimensions are in mm

Dimension
Model

190
VIEW ALL ABQ-C TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

ABQ71C ABQ100C

INDOOR
UNITS
SUPER HIGH
SUPER HIGH

External Static Pressure (Pa)


External Static Pressure (Pa)

HIGH
HIGH

OUTDOOR
UNITS
MEDIUM
MEDIUM Lower limit
Lower limit of external static
LOW of external static pressure
pressure LOW

AIR CURTAINS
BIDDLE
Airflow (CFM)

Airflow (CFM)

VENTILATION
ABQ125C ABQ140C

CONTROL
SYSTEMS
ABQ125CV1 BLOWER PERFORMANCE CURVE

250

& ACCESSORIES
OPTIONS
200
External Static Pressure (Pa)

SUPER HIGH

SUPER HIGH
HIGH
External Static Pressure (Pa)

150
& PLATFORMS

HIGH
TOOLS

MEDIUM

MEDIUM
LOW Lower limit
100
LOW of external static
pressure

atic
l st
rna
f exte
to re
imi ressu
er l p
Low
TECHNICAL
DRAWINGS

50

Airflow (CFM)

0
1000 1200 1400 1600 1800 2000

Airflow (CFM)
PREVIOUS

2056-015

191
VIEW ALL FAA-A TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FAA100A
FAA71A

Required space
50 OR MORE
360
440
510

Front grille fixing screws Manufacturer label

30 OR MORE
ABOUT 440

Required space
Including mounting plate
242
240 Indoor air flow
Knockout hole.

2500 OR MORE
120 OR LESS

30 OR MORE
Minimum space for air passage
340

Location of nameplate
Knockout hole.
Blade
50 OR MORE 1200 50 OR MORE
Required space Required space
Blade angle Standard location of holes in the wall
Up/down (automatic) 79.5 1085.2 35.5
14.5

Cooling Outside diameter


Heating Fan
Dry

31° 26°
36°
42° 38° 34° 0
Ø8
Left/right (manual) Ø8
0

114
45

45
45° 45° Hole for embedded piping About 400mm 89
65
Gas pipe
Notes Ø15.9mm CuT Hole for embedded piping
The __________ mark shows the piping direction.
About 460mm
When installing a wireless controller, there will be a receiver on this location. For
details, see the drawing of the wireless controller. Liquid pipe
Ø9.5mm CuT
Do not place any objects under the indoor unit. In case of high humidity (>80%), cl About 465mm

3D106731
ogged drain outlets, or dirty air filters, condensate may drop out. Drain hose
I.D.Ø15mm O.D. Ø18mm

FAA100A
FAA100A 50 OR MORE
Required space

360
440
510

Front grille fixing screws Manufacturer label


30 OR MORE

ABOUT 440
Required space

Including mounting plate


242
240 Indoor air flow
Knockout hole.
2500 OR MORE

120 OR LESS
30 OR MORE
Minimum space for air passage
340

Location of nameplate
Knockout hole.
Blade
50 OR MORE 1200 50 OR MORE
Required space Required space
Blade angle Standard location of holes in the wall
Up/down (automatic) 79.5 1085.2 35.5
14.5

Cooling Outside diameter


Heating Fan
Dry

31° 26°
36°
42° 38° 34° 0
Ø8
Left/right (manual) Ø8
0
114
45

45

45° 45° Hole for embedded piping About 400mm 89


65
Gas pipe
Notes Ø15.9mm CuT Hole for embedded piping
The __________ mark shows the piping direction.
About 460mm
When installing a wireless controller, there will be a receiver on this location. For
details, see the drawing of the wireless controller. Liquid pipe
Ø9.5mm CuT
Do not place any objects under the indoor unit. In case of high humidity (>80%), cl About 465mm

3D106731
ogged drain outlets, or dirty air filters, condensate may drop out. Drain hose
I.D.Ø15mm O.D. Ø18mm

192
VIEW ALL FHA-A TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FHA35A
FHA35A Connection position of fresh air intake kit
120
Ø100 Knockout hole. 90
63
210

92
175
90
156 Number Name Description

115
157

1 Air discharge grille


105
2 Air suction grille

INDOOR
60 51 102 3 Air filter

UNITS
63

40
9 12 16
4 Gas pipe connection Ø9,5 flare
59 134 18 17 20 131

30
87
57 5 Liquid pipe connection Ø6,4 flare

35
Position of knockout hole for piping intake (rear) Drain pipe connection
6 VP20

163
100
Rear view Terminal block with earth terminal

189
210
7 Located inside of the unit
M4

195
Standard location of holes in the wall 8 Metal hanger

Position of knockout hole Rear side


Piping intake (rear) 9
Position of knockout hole Top
10 10

260
Piping intake (right) Knockout hole.
11
Required space

220 Drain piping intake (left-rear)


8 12 Knockout hole.
103 13 Drain piping intake (left) Knockout hole.
5

14 Drain piping intake (right) Knockout hole.

Standard location of holes in the wall


15
180

Ø100
175

Piping intake (rear)

OUTDOOR
16

UNITS
Drain piping intake (top) Ø60
Suspension bolt pitch

920 17 Gas piping intake (top) Ø36

Suspension bolt pitch 18 Liquid piping intake (top) Ø26


15 19
19 Power supply wiring and control wiring intake (rear) Ø29

Rear view 20 Power supply wiring and control wiring intake (top) Ø29
Required space

690 Suspension bolt 4


1
4-M8~M10
5

5 11

91
131
197

197
235

14
45 57

AIR CURTAINS
57 13 30 or more 960 30 or more 6 Ø
Service space Front side Service space
300

Required space

BIDDLE
2500 or more

Brand name label

Suction-side obstacle Note 2

Drain pipe connection

Notes
268

268
221
214

VENTILATION
1) Location of nameplate
Bottom of the fan housing inside the suction grille
2) When installing a wireless controller, there will be a receiver on this location. For 3 2 83
details, see the drawing of the wireless controller. 76 7
105
5 4
156

3) Do not place any objects under the indoor unit. In case of high humidity (>80%), clogged drain outlets, or dirty air filters, condensate may drop out.

3D106574A
FHA50A
FHA50A

CONTROL
120

SYSTEMS
Connection position of fresh air intake kit
Ø100 Knockout hole. 90
63

210
92
175
90

156 Number Name Description


115
157

1 Air discharge grille


105
2 Air suction grille

60 51 102 3 Air filter


63
40

9 12 16 Gas pipe connection Ø12,7 flare


4
59 134 18 17 20 131
30
87

57 5
35

Liquid pipe connection Ø6,4 flare


Position of knockout hole for piping intake (rear) 6 Drain pipe connection VP20
163
100

189

Rear view Terminal block with earth terminal


210

7 Located inside of the unit


M4
195

& ACCESSORIES
Standard location of holes in the wall 8 Metal hanger

Piping intake (rear)


9 Position of knockout hole Rear side

OPTIONS
10 10 Position of knockout hole Top
260

11 Piping intake (right) Knockout hole.

220
Required space

8 12 Drain piping intake (left-rear) Knockout hole.


103 13 Drain piping intake (left) Knockout hole.
5

14 Drain piping intake (right) Knockout hole.

Standard location of holes in the wall


15 Ø100
180
175

Piping intake (rear)

16 Drain piping intake (top) Ø60


Suspension bolt pitch

920 17 Gas piping intake (top) Ø36

Suspension bolt pitch 18 Liquid piping intake (top) Ø26


15 19
19 Power supply wiring and control wiring intake (rear) Ø29

Rear view 20 Power supply wiring and control wiring intake (top) Ø29
Required space

690 Suspension bolt 4


1
& PLATFORMS

4-M8~M10
5

5 11
91

TOOLS
131
197

197
235

14
57 30 or more 960 30 or more 6 45 57
Required space

13 Ø
Service space Service space
300

Front side
2500 or more

Brand name label

Suction-side obstacle Note 2

Drain pipe connection


TECHNICAL
DRAWINGS

6
268

268
221
214

Notes

1)Location of nameplate 3 2 83
76 7
Bottom of the fan housing inside the suction grille
105
5 4
2) When installing a wireless controller, there will be a receiver on this location. 156
For details, see the drawing of the wireless controller.

3) Do not place any objects under the indoor unit. In case of high humidity (>80%), clogged drain outlets, or dirty air filters, condensate may drop out.

3D109224A
PREVIOUS

193
VIEW ALL FHA-A TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FHA60A
FHA60A
9
Connection position of fresh air intake kit

Ø100 Knockout hole. 90


120

63

92

175
90
115
210

157
Number Name Description
156 1 Air discharge grille
105 2 Air suction grille
16

40
Position of knockout hole for piping intake (rear)
59 63 60 51 102 3 Air filter
Rear view
12 18 17 20 131 57 4 Gas pipe Ø 12,7 FLARE

30
87

35
134 5 Liquid pipe Ø 6,4 FLARE

6 Drain pipe connection VP20

163
100
210.6

189
Standard location of holes in the wall
Terminal block with earth terminal

195
Piping intake (rear) 7 Located inside of the unit M4

8 Metal hanger
Required space

9 Position of knockout hole Rear side

260
220 10 10 Position of knockout hole Top

103 11 Piping intake (right) Knockout hole.


116
5

12 Drain piping intake (left-rear) Knockout hole.


8 13 Drain piping intake (left) Knockout hole.
180
175

14 Drain piping intake (right) Knockout hole.

Suspension bolt pitch


Standard location of holes in the wall
15 Piping intake (rear)
Ø100

16 Drain piping intake (top) Ø60


15 1230
19 17 Gas piping intake (top) Ø36
Rear view
Suspension bolt pitch 18 Liquid piping intake (top) Ø26
Required space

19 Power supply wiring and control wiring intake (rear) Ø29

690 20 Power supply wiring and control wiring intake (top) Ø29
SUSPENSION BOLT
1
5

4-M8~M10 4 5 11

91
131

197
235
197

45 57 14
300 OR MORE

13 6 Ø
57 30 OR MORE 1270 30 OR MORE
Required space
2500 OR MORE

Service space Front side Service space

Brand name label


Suction-side obstacle
Note 2
Floor

Drain pipe connection 6


Piping connection LEFT
Notes

1) Location of nameplate
Bottom of the fan housing inside the suction grille
268

268
221
2) When installing a wireless controller, there will be a receiver on this location.
214
For details, see the drawing of the wireless controller.
83
3 2 7 5 4
76 105

156
3) Do not place any objects under the indoor unit. In case of high humidity (>80%), clogged drain outlets, or dirty
air filters, condensate may drop out.

3D106552

FHA71A

FHA71A 9
Connection position of fresh air intake kit
Ø100 Knockout hole. 90
120
63

92

175
90
115

210 Name Description


157

Number
156 1 Air discharge grille
105 2 Air suction grille
16
40

Position of knockout hole for piping intake (rear)


59 63 60 51 102 3 Air filter
Rear view Gas pipe
12 18 17 20 131 57 4 Ø15,9 FLARE
30
87

35

134 5 Liquid pipe Ø9,5 FLARE

6 Drain pipe connection VP20


163
100
210.6

189

Standard location of holes in the wall


Terminal block with earth terminal
195

Piping intake (rear) 7 M4


Located inside of the unit
8 Metal hanger
Required space

9 Position of knockout hole Rear side


220
260

10 Position of knockout hole Top


10
103 11 Piping intake (right) Knockout hole.
5

Suspension bolt pitch

116 12 Drain piping intake (left-rear) Knockout hole.


8 13 Drain piping intake (left) Knockout hole.
180
175

14 Drain piping intake (right) Knockout hole.


Standard location of holes in the wall
15 Piping intake (rear)
Ø100

15 16 Drain piping intake (top) Ø60


19 1230 Gas piping intake (top) Ø36
17
Rear view
Suspension bolt pitch 18 Liquid piping intake (top) Ø26
Ø29
Required space

19 Power supply wiring and control wiring intake (rear)

690 20 Power supply wiring and control wiring intake (top) Ø29
SUSPENSION BOLT
5

4-M8~M10 1 4 5 11
91
131

197
235
197

5 14
Ø4 57
300 OR MORE

13 6
Required space

57 30 OR MORE 1270 30 OR MORE


2500 OR MORE

Service space Service space


Front side

Brand name label


Suction-side obstacle
Note 2

Floor

Drain pipe connection 6


Piping connection LEFT

Notes
262.2

268
221
214

1) Location of nameplate
Bottom of the fan housing inside the suction grille

2) When installing a wireless controller, there will be a receiver on this location. 83


For details, see the drawing of the wireless controller. 3 2 7 5 4
76 105

156
3) Do not place any objects under the indoor unit. In case of high humidity (>80%), clogged drain outlets, or dirty air filters, condensate may drop out.

3D109222
194
VIEW ALL FHA-A TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FHA100-140A
FHA100-140A Connection position of fresh air intake kit
120
9 Ø100 Knockout hole. 90

63

92

175
90
115
Number
Name Description
157 210
12 1 Air discharge grille
156 2 Air suction grille

INDOOR
40
16 105

UNITS
63 Position of knockout hole for piping intake (rear) 60 51 3 Air filter
102 Ø15, 9FLARE

87
30
59 134 Rear view 18 17 20 131 4 Gas pipe
57

35
5 Liquid pipe Ø9, 5FLARE
Standard location of holes in the wall
6 Drain pipe connection VP20

163
100

189
Terminal block with earth terminal

210
Piping intake (rear) 7 M4

195
Located inside of the unit
8 Metal hanger
Required space

222
9 Position of knockout hole Rear side
103 116 10 Position of knockout hole Top

260
10
5

11 Piping intake (right) Knockout hole.


12 Drain piping intake (left) Knockout hole.
19 13 Drain piping intake (right) Knockout hole.
180
175

14 Drain piping intake (left-rear) Knockout hole.


Suspension bolt pitch

8 Standard location of holes in the wall


15 Ø100
Piping intake (rear)

OUTDOOR
15 Ø60
1550 16 Drain piping intake (top)

UNITS
17 Gas piping intake (top) Ø36
Required space

Rear view Suspension bolt pitch


18 Liquid piping intake (top) Ø26
19 Power supply wiring and control wiring intake (rear) Ø29
690 SUSPENSION BOLT 1 20 Power supply wiring and control wiring intake (top) Ø29
5

4-M8~M10 4 5 11

91
131
197
197

5 14
Ø4
300 OR MORE

13 6 57
Required space

30 OR MORE 1590 30 OR MORE


Front side
2500 OR MORE

57 Service space Service space

AIR CURTAINS
BIDDLE
Brand name label
Suction-side obstacle Note 2
Floor

Drain pipe connection 6

Piping connection LEFT

Notes
268

268
221
1) Location of nameplate 214

VENTILATION
Bottom of the fan housing inside the suction grille 83
2) When installing a wireless controller, there will be a receiver 76 105 4
on this location. For details, see the drawing of the wireless controller. 3 2 7 5 156

3) Do not place any objects under the indoor unit. In case of high humidity (>80%), clogged drain outlets, or dirty air filters, condensate may drop out.

3D106530A

CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

195
• Indoor Unit • AHQ-C
VIEW ALL AHQ-C TECHNICAL

4 DetailedDimensional
technical drawings drawings
DRAWINGS ON MY.DAIKIN.EU

AHQ71-125C
• Indoor Unit • AHQ-C All dimensions are in mm

4 Dimensional drawings
4

Dimension
Model

AHQ140C

All dimensions are in mm

Dimension
Model

6 • Split - Sky Air • AHQ-C

196
VIEW ALL FUA-A TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FUA-A
FUA-A
Notes
1.The unit nameplate is located on the control box cover.
2.When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller. When closing the air outlet, the required space is 30mm or more. Note (3)
3.When closing the discharge grille in case of 2-way blow or 3-way blow, there are limitations to the piping connection direction. See the installation manual.
4.Do not place any objects under the indoor unit. In case of high humidity (>80%), clogged drain outlets, or dirty air filters, condensate may drop out. 1500mm or more

INDOOR
1500mm or more

UNITS
Required space

Brand name label Brand name label


Note 2
950
835 Suspension position 1500mm or more

5
1500mm or more

CEIL ING SUSP ENDE D FLEX T YPE

AI R CO NDIT IONE R

835 Suspension position

OUTDOOR
UNITS
950
2

7 9
60 100

176
171
88

AIR CURTAINS
105
145 159

BIDDLE
Gas piping and drain piping connection (from top) Gas piping and drain piping connection (from rear)
198 3 1
11 10 8 4 Suspension bolt
Gas piping and drain piping connection (from right)
4-M8~ M10
11
57
171

88
120
108

20
145
89
88

198
105
141

89

105
88
39

141
A Arrow view 140 14 6 90 70 2500mm or more
179 Required space
600

A arrow view 198


34
23

11
57

L-type piping kit (upward direction) 15.9 flared connection


57

88
88

120

VENTILATION
120

Drain pipe connection (outside diameter 26)


88

10
9 Pipe cover (top) Suspension bolt pitch
8 Piping connection Rear/ Wiring connection Height
7 Piping connection right/ Wiring connection
10 6 Corner decoration cover
The drain piping can be raised up to 600mm from the top surface of the unit.
5 Air suction grille
4 Air discharge outlet

3D106356
3 Drain socket VP20
2 Gas pipe connection 15.9 flare
1 Liquid pipe connection 9.5 flare

CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

197
VIEW ALL FVA-A TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FVA71A
FVQ71C

This model to be fixed with


4-Ø 14 Hole
Suction grill fixture as shown below.
(for bolt)
stopper ln case of fixing it at the bottom

ln case vibration resistance is


required, fix it at both the
bottom and the rear.
0.7

Detail B A View
(Two both sides)
Pull out direction of
air-filter
Fixture
(Accessory) 2-7x15 Oblong hole
(For wood screw)

(Pull out dimension of


740 or more

air-filter 50 or more 50 or more

Approx. 46
Full open 1500 or more
position of
suction grille Required space

1 Suction grille
2 Air filter
3 Through hole for side piping 70x90 oblong slit hole
4 Through hole for side piping Ø 80 slit hole
5 Through hole for side wiring Ø 27slit hole
6 Through hole for rear piping/wiring 80x130 oblong slit hole
7 Through hole for bottom piping/wiring 126x130 square hole
8 Liquid pipe connection Ø 9.5 (flare connection)
9 Gas pipe connection Ø 15.9 (flare connection)
Note 1. Sticking location for manufacturer’s
10 Drain pipe connection VP20
label: On the surface of cover of switch
box inside the suction grille.

FVA100-125-140A

FVQ100-125-140C

4-Ø 14 Hole This model to be fixed with


Suction grill (for bolt) fixture as shown below.
stopper ln case of fixing it at the bottom

ln case vibration resistance is


required, fix it at both the
bottom and the rear.
0.7

Detail B A View
(Two both sides) Pull out direction of
air-filter

Fixture
2-7x15 Oblong hole
(Accessory)
(For wood screw)
(Pull out dimension of
740 or more

air-filter

50 or more 50 or more

Approx. 46
Full open 1500 or more
position of Required space
suction grille
1 Suction grille
2 Air filter
3 Through hole for side piping 70x90 oblong slit hole
4 Through hole for side piping Ø 80 slit hole
5 Through hole for side wiring Ø 27slit hole
6 Through hole for rear piping/wiring 80x130 oblong slit hole
7 Through hole for bottom piping/wiring 126x130 square hole
8 Liquid pipe connection Ø 9.5 (flare connection)
9 Gas pipe connection Ø 15.9 (flare connection)
Note 1. Sticking location for manufacturer’s 10 Drain pipe connection VP20
label: On the surface of cover of switch
box inside the suction grille.

198
VIEW ALL FNA-A TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FNA25-35A
FNQ25-35A

790 300
ARROW VIEW B

680
662

620
4x150=600

80

200
170
156
ARROW VIEW A

INDOOR
UNITS
Inspection door
20 or more

12.5
14-M4

57.5

19.5
740
20 or more
Suspension position 100 48
5x100= 500 16-Ø 4.7 HOLE
Suspension bolt
24 90

60
KB 4-M8~M10
KH KH

130
KA

Suspension position

330
KC

63
500

620

179.4
723
100 or more

100

OUTDOOR
ARROW VIEW A KD

310

UNITS
KF

KK KJ KE

8.4
48
5x100= 500 16-Ø 4.3 HOLE 46
300 or more 790
Service space 50 601 171
240 or more

42
10

50
KJ ARROW VIEW B
Front suction
KG

4- Ø 5 HOLE

100
116
180
5x100= 500

AIR CURTAINS
16- Ø 4.3 HOLE 601
810

BIDDLE
830
Bottom suction
Item Name Description
KA Liquid pipe connection port Ø 6.40 flared connection
KB Gas pipe connection port Ø 9.50 flared connection
KC Drain pipe connection VP20 (OD Ø26, ID Ø20)
KD Drain hose ID Ø25
KE Control box /
KF Transmission line /
KG Power supply connection /
/

VENTILATION
KH Suspension bracket
KJ Air filter /
KK Mounting foot / Notes
1. When installing optional accessories, refer to their respective documentation.
2. The ceiling depth varies according to the documentation of the specific system.

3D096751

FNA50-60A
FNQ50-60A

CONTROL
SYSTEMS
1190 300 ARROW VIEW B

1080
1060
6x150= 900
620

200
156
170
80

ARROW VIEW A
Inspection door
57.5

12.5

18-M4
19.5

& ACCESSORIES
OPTIONS
20 or more 1140
Suspension position
20 or more
10x100= 1000
100 48
Suspension bolt 26- Ø 4.7 HOLE 24 90
60

4-M8~M10
KB
KH KH
130

KA
330
Suspension position

KC
63
500

620

179.4
723

100
100 or more

KD
310

ARROW VIEW A
& PLATFORMS

KF
TOOLS

KK KJ KE
8.4
48

9x100= 900
46
300 or more 1190 50 1001 24- Ø 4.3 HOLE 171
240 or more Service space
42
50
10

KJ ARROW VIEW B

KG Front suction

4- Ø 5 HOLE
116
100
180

9x100= 900
24- Ø 4.3 HOLE
1001 75
1210
1230
TECHNICAL

Bottom suction
DRAWINGS

Item Name Description


KA Liquid pipe connection port Ø6.4 flared connection
KB Gas pipe connection port Ø12.70 flared connection
KC Drain pipe connection VP20 (OD Ø26, ID Ø20)
KD Drain hose ID Ø25
KE Control box /
KF Transmission line /
KG Power supply connection /
KH Suspension bracket /

KJ Air filter /
KK Mounting foot / Notes
PREVIOUS

1. When installing optional accessories, refer to their respective documentation.


2. The ceiling depth varies according to the documentation of the specific system.

3D096750
199
VIEW ALL FNA-A TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FNA25-35A
S25-35A
(Pa)
(mmH2O) (mmH2O)

External static pressure

Upper limit of external


static pressure

SL

(Pa)
(mmH2O) (mmH2O)

Air flow rate (m3/min)

0A FNA50A
(mmH2O) (Pa) (mmH2O)
External static pressure

Upper limit of external


static pressure
H

Lower limit of external


SL static pressure

(mmH2O) (Pa) Air flow rate (m3/min) (mmH2O)

200
VIEW ALL FNA-A TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

FNA60A

(Pa)
(mmH2O) (mmH2O)

INDOOR
UNITS
OUTDOOR
UNITS
External static pressure

Upper limit of external


static pressure
H

AIR CURTAINS
BIDDLE
L

Lower limit of external


static pressure
SL

VENTILATION
(Pa)

(mmH2O) (mmH2O)

Air flow rate (m3/min)

CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

201
Technical drawings

Outdoor units
RZAG-MV1/MY1 199
RZASG-MV1/MY1 209
AZAS-MV1/MY1 216
RZQG-L9V1/L(8)Y1 222
RZQSG-L3/9V1 / L(8)Y1 235
AZQS-B(8)V1/BY1 243
RZQ-C 247

202
VIEW ALL RZAG-MV1 TECHNICAL
RZAG71-100MV1

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZAG71-100MV1 COMFORT COOLING


Compressor OFM IFM

Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAHG71GVEB RZAG71M7V1B 17,5 − 20 − 15,5 0,094 0,8 0,091 0,5


− −

INDOOR
FCAG35AVEB x2 RZAG71M7V1B 17,6 20 15,5 0,094 0,8 0.044 x2 0.3 x2

UNITS
FCAG71AVEB RZAG71M7V1B 17,4 − 20 − 15,5 0,094 0,8 0,054 0,4
FFA35A2VEB x2 RZAG71M7V1B 17,8 − 20 − 15,5 0,094 0,8 0.050 x2 0.4 x2
− −

Minimum: 198 V

Maximum 264 V
FBA35A2VEB x2 RZAG71M7V1B 18,2 20 15,5 0,094 0,8 0.089 x2 0.6 x2
FBA71A2VEB RZAG71M7V1B 17,6 − 20 − 15,6 0,094 0,8 0,070 0,5
50Hz ~
FNA35A2VEB x2 RZAG71M7V1B 17,3 − 20 − 15,5 0,094 0,8 0.034 x2 0,3
220-240V
FUA71AVEB RZAG71M7V1B 17,9 − 20 − 15,5 0,094 0,8 0,046 0,9
FAA71AUVEB RZAG71M7V1B 17,4 − 20 − 15,5 0,094 0,8 0,048 0,4
FVA71AMVEB RZAG71M7V1B 17,6 − 20 − 15,5 0,094 0,8 0,117 0,6
FDXM35F3V1B x2 RZAG71M7V1B 17,6 − 20 − 15,5 0,094 0,8 0.034 x2 0.3 x2
FHA35AVEB x2 RZAG71M7V1B 18,2 − 20 − 15,5 0,094 0,8 0.060 x2 0.6 x2
FHA71AVEB RZAG71M7V1B 17,8 − 20 − 15,5 0,094 0,8 0,091 0,8

OUTDOOR
FCAHG100GVEB RZAG100M7V1B 27,4 − 32 − 23,5 0.094+0.094 0.75+0.75 0,221 1,3

UNITS
FCAG35AVEB x3 RZAG100M7V1B 26,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.044 x3 0.3 x3
FCAG50AVEB x2 RZAG100M7V1B 26,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0.039 x2 0.3 x2
FCAG100AVEB RZAG100M7V1B 26,7 − 32 − 23,5 0.094+0.094 0.75+0.75 0,117 0,7
FFA35A2VEB x3 RZAG100M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x3 0.4 x3
FFA50A2VEB x2 RZAG100M7V1B 26,8 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x2 0.4 x2
FBA35A2VEB x3 RZAG100M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.089 x3 0.6 x3
− −
Minimum: 198 V

Maximum 264 V

FBA50A2VEB x2 RZAG100M7V1B 27,2 32 23,5 0.094+0.094 0.75+0.75 0.089 x2 0.6 x2


FBA100A2VEB RZAG100M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0,127 1,0
50Hz ~
FNA35A2VEB x3 RZAG100M7V1B 26,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.034 x3 0.3 x3
220-240V
FNA50A2VEB x2 RZAG100M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x2 0.5 x2
− −

AIR CURTAINS
FUA100AVEB RZAG100M7V1B 27,4 32 23,5 0.094+0.094 0.75+0.75 0,106 1,3
FAA100AUVEB RZAG100M7V1B 26,4 − 32 − 23,5 0.094+0.094 0.75+0.75 0,064 0,4

BIDDLE
FVA100AMVEB RZAG100M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0,238 1,2
FDXM35F3V1B x3 RZAG100M7V1B 26,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.034 x3 0.3 x3
FDXM50F3V1B x2 RZAG100M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x2 0.5 x2
FHA35AVEB x3 RZAG100M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.6 x3
FHA50AVEB x2 RZAG100M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x2 0.6 x2
FHA100AVEB RZAG100M7V1B 27,4 − 32 − 23,5 0.094+0.094 0.75+0.75 0,150 1,3

3D110014A

RZAG125-140MV1 3D110014A

VENTILATION
RZAG125-140MV1
Compressor OFM IFM

Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAHG125GVEB RZAG125M7V1B 27,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0,244 1,4


FCAG35AVEB x4 RZAG125M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.044 x4 0.3 x4
FCAG50AVEB x3 RZAG125M7V1B 26,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.039 x3 0.3 x3

CONTROL
SYSTEMS
FCAG60AVEB x2 RZAG125M7V1B 26,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0.044 x2 0.3 x2
FCAG125AVEB RZAG125M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0,168 1,0
FFA35A2VEB x4 RZAG125M7V1B 27,7 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x4 0.4 x4
FFA50A2VEB x3 RZAG125M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x3 0.4 x3
FFA60A2VEB x2 RZAG125M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x2 0.6 x2
FBA35A2VEB x4 RZAG125M7V1B 28,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0.089 x4 0.6 x4
FBA50A2VEB x3 RZAG125M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.089 x3 0.6 x3
− −
Minimum: 198 V

Maximum 264 V

FBA60A2VEB x2 RZAG125M7V1B 27,0 32 23,5 0.094+0.094 0.75+0.75 0.070 x2 0.5 x2


FBA125A2VEB RZAG125M7V1B 27,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0,187 1,5
50Hz ~
FNA35A2VEB x4 RZAG125M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4

& ACCESSORIES
220-240V
FNA50A2VEB x3 RZAG125M7V1B 27,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3
− −

OPTIONS
FNA60A2VEB x2 RZAG125M7V1B 27,0 32 23,5 0.094+0.094 0.75+0.75 0.060 x2 0.5 x2
FUA125AVEB RZAG125M7V1B 27,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0,106 1,4
FDA125A5VEB RZAG125M7V1B 28,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0,350 2,1
FVA125AMVEB RZAG125M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0,238 1,2
FDXM35F3V1B x4 RZAG125M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4
FDXM50F3V1B x3 RZAG125M7V1B 27,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3
FDXM60F3V1B x2 RZAG125M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x2 0.5 x2
FHA35AVEB x4 RZAG125M7V1B 28,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x4 0.6 x4
FHA50AVEB x3 RZAG125M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.6 x3
FHA60AVEB x2 RZAG125M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.091 x2 0.6 x2
FHA125AVEB RZAG125M7V1B 27,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0,150 1,5
− −
& PLATFORMS

FCAHG71GVEB x2 RZAG140M7V1B 27,0 32 23,5 0.094+0.094 0.75+0.75 0.091 x2 0.5 x2


FCAHG140GVEB RZAG140M7V1B 27,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0,244 1,4
TOOLS

FCAG35AVEB x4 RZAG140M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.044 x4 0.3 x4


FCAG50AVEB x3 RZAG140M7V1B 26,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.039 x3 0.3 x3
FCAG71AVEB x2 RZAG140M7V1B 26,8 − 32 − 23,5 0.094+0.094 0.75+0.75 0.054 x2 0.4 x2
FCAG140AVEB RZAG140M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0,168 1,0
FFA35A2VEB x4 RZAG140M7V1B 27,7 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x4 0.4 x4
FFA50A2VEB x3 RZAG140M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x3 0.4 x3
FBA35A2VEB x4 RZAG140M7V1B 28,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0.089 x4 0.6 x4
FBA50A2VEB x3 RZAG140M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.089 x3 0.6 x3
Minimum: 198 V

Maximum 264 V

FBA71A2VEB x2 RZAG140M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0.070 x2 0.5 x2


FBA140A2VEB RZAG140M7V1B 50Hz ~ 27,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0,187 1,5
FNA35A2VEB x4 RZAG140M7V1B 220-240V 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4
TECHNICAL
DRAWINGS

FNA50A2VEB x3 RZAG140M7V1B 27,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3


FUA71AVEB x2 RZAG140M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.046 x2 0.9 x2
FAA71AUVEB x2 RZAG140M7V1B 26,8 − 32 − 23,5 0.094+0.094 0.75+0.75 0.048 x2 0.4 x2
FVA71AMVEB x2 RZAG140M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.117 x2 0.6 x2
FVA140AMVEB RZAG140M7V1B 27,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0,276 1,4
FDXM35F3V1B x4 RZAG140M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4
FDXM50F3V1B x3 RZAG140M7V1B 27,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3
FHA35AVEB x4 RZAG140M7V1B 28,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x4 0.6 x4
FHA50AVEB x3 RZAG140M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.6 x3
FHA71AVEB x2 RZAG140M7V1B 27,7 − 32 − 23,5 0.094+0.094 0.75+0.75 0.091 x2 0.8 x2
FHA140AVEB RZAG140M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0,150 1,8
PREVIOUS

3D110014A
3D110014A
203
VIEW ALL RZAG-MY1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
RZAG71-100MY1
Detailed technical drawings

RZAG71-100MY1 COMFORT COOLING


Compressor OFM IFM

Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAHG71GVEB RZAG71M7Y1B 10,9 − 16 − 9,2 0,094 0,8 0,091 0,5


FCAG35AVEB x2 RZAG71M7Y1B 11,0 − 16 − 9,2 0,094 0,8 0.044 x2 0.3 x2
FCAG71AVEB RZAG71M7Y1B 10,8 − 16 − 9,2 0,094 0,8 0,054 0,4
FFA35A2VEB x2 RZAG71M7Y1B 11,2 − 16 − 9,2 0,094 0,8 0.050 x2 0.4 x2
− −

Minimum: 342 V

Maximum 456 V
FBA35A2VEB x2 RZAG71M7Y1B 11,6 16 9,2 0,094 0,8 0.089 x2 0.6 x2
FBA71A2VEB RZAG71M7Y1B 10,9 − 16 − 9,2 0,094 0,8 0,070 0,5
3N~ 50Hz
FNA35A2VEB x2 RZAG71M7Y1B 10,7 − 16 − 9,2 0,094 0,8 0.034 x2 0,3
380-415V
FUA71AVEB RZAG71M7Y1B 11,3 − 16 − 9,2 0,094 0,8 0,046 0,9
FAA71AUVEB RZAG71M7Y1B 10,8 − 16 − 9,2 0,094 0,8 0,048 0,4
FVA71AMVEB RZAG71M7Y1B 11,0 − 16 − 9,2 0,094 0,8 0,117 0,6
FDXM35F3V1B x2 RZAG71M7Y1B 11,0 − 16 − 9,2 0,094 0,8 0.034 x2 0.3 x2
FHA35AVEB x2 RZAG71M7Y1B 11,6 − 16 − 9,2 0,094 0,8 0.060 x2 0.6 x2
FHA71AVEB RZAG71M7Y1B 11,2 − 16 − 9,2 0,094 0,8 0,091 0,8
FCAHG100GVEB RZAG100M7Y1B 15,4 − 16 − 12,0 0.094+0.094 0.75+0.75 0,221 1,3
FCAG35AVEB x3 RZAG100M7Y1B 12,9 − 16 − 10,0 0.094+0.094 0.75+0.75 0.044 x3 0.3 x3
FCAG50AVEB x2 RZAG100M7Y1B 13,6 − 16 − 11,0 0.094+0.094 0.75+0.75 0.039 x2 0.3 x2
FCAG100AVEB RZAG100M7Y1B 14,8 − 16 − 12,0 0.094+0.094 0.75+0.75 0,117 0,7
FFA35A2VEB x3 RZAG100M7Y1B 13,2 − 16 − 10,0 0.094+0.094 0.75+0.75 0.050 x3 0.4 x3
FFA50A2VEB x2 RZAG100M7Y1B 13,8 − 16 − 11,0 0.094+0.094 0.75+0.75 0.050 x2 0.4 x2
FBA35A2VEB x3 RZAG100M7Y1B 13,8 − 16 − 10,0 0.094+0.094 0.75+0.75 0.089 x3 0.6 x3
− −
Minimum: 342 V

Maximum 456 V

FBA50A2VEB x2 RZAG100M7Y1B 14,2 16 11,0 0.094+0.094 0.75+0.75 0.089 x2 0.6 x2


FBA100A2VEB RZAG100M7Y1B 15,1 − 16 − 12,0 0.094+0.094 0.75+0.75 0,127 1,0
3N~ 50Hz
FNA35A2VEB x3 RZAG100M7Y1B 12,9 − 16 − 10,0 0.094+0.094 0.75+0.75 0.034 x3 0.3 x3
380-415V
FNA50A2VEB x2 RZAG100M7Y1B 14,0 − 16 − 11,0 0.094+0.094 0.75+0.75 0.060 x2 0.5 x2
FUA100AVEB RZAG100M7Y1B 15,4 − 16 − 12,0 0.094+0.094 0.75+0.75 0,106 1,3
FAA100AUVEB RZAG100M7Y1B 14,5 − 16 − 12,0 0.094+0.094 0.75+0.75 0,064 0,4
FVA100AMVEB RZAG100M7Y1B 15,3 − 16 − 12,0 0.094+0.094 0.75+0.75 0,238 1,2
FDXM35F3V1B x3 RZAG100M7Y1B 12,9 − 16 − 10,0 0.094+0.094 0.75+0.75 0.034 x3 0.3 x3
FDXM50F3V1B x2 RZAG100M7Y1B 14,0 − 16 − 11,0 0.094+0.094 0.75+0.75 0.060 x2 0.5 x2
FHA35AVEB x3 RZAG100M7Y1B 13,8 − 16 − 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.6 x3
FHA50AVEB x2 RZAG100M7Y1B 14,2 − 16 − 11,0 0.094+0.094 0.75+0.75 0.060 x2 0.6 x2
FHA100AVEB RZAG100M7Y1B 15,4 − 16 − 12,0 0.094+0.094 0.75+0.75 0,150 1,3

3D110014A

RZAG125-140MY1
RZAG125-140MY1
Compressor OFM IFM
3D110014A
Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAHG125GVEB RZAG125M7Y1B 15,0 − 16 − 11,5 0.094+0.094 0.75+0.75 0,244 1,4


FCAG35AVEB x4 RZAG125M7Y1B 12,2 − 16 − 9,0 0.094+0.094 0.75+0.75 0.044 x4 0.3 x4
FCAG50AVEB x3 RZAG125M7Y1B 12,9 − 16 − 10,0 0.094+0.094 0.75+0.75 0.039 x3 0.3 x3
FCAG60AVEB x2 RZAG125M7Y1B 14,1 − 16 − 11,5 0.094+0.094 0.75+0.75 0.044 x2 0.3 x2
FCAG125AVEB RZAG125M7Y1B 14,6 − 16 − 11,5 0.094+0.094 0.75+0.75 0,168 1,0
FFA35A2VEB x4 RZAG125M7Y1B 12,6 − 16 − 9,0 0.094+0.094 0.75+0.75 0.050 x4 0.4 x4
FFA50A2VEB x3 RZAG125M7Y1B 13,2 − 16 − 10,0 0.094+0.094 0.75+0.75 0.050 x3 0.4 x3
FFA60A2VEB x2 RZAG125M7Y1B 14,8 − 16 − 11,5 0.094+0.094 0.75+0.75 0.050 x2 0.6 x2
FBA35A2VEB x4 RZAG125M7Y1B 13,4 − 16 − 9,0 0.094+0.094 0.75+0.75 0.089 x4 0.6 x4
FBA50A2VEB x3 RZAG125M7Y1B 13,8 − 16 − 10,0 0.094+0.094 0.75+0.75 0.089 x3 0.6 x3
− −
Minimum: 342 V

Maximum 456 V

FBA60A2VEB x2 RZAG125M7Y1B 14,6 16 11,5 0.094+0.094 0.75+0.75 0.070 x2 0.5 x2


FBA125A2VEB RZAG125M7Y1B 15,1 − 16 − 11,5 0.094+0.094 0.75+0.75 0,187 1,5
3N~ 50Hz
FNA35A2VEB x4 RZAG125M7Y1B 12,2 − 16 − 9,0 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4
380-415V
FNA50A2VEB x3 RZAG125M7Y1B 13,5 − 16 − 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3
FNA60A2VEB x2 RZAG125M7Y1B 14,6 − 16 − 11,5 0.094+0.094 0.75+0.75 0.060 x2 0.5 x2
FUA125AVEB RZAG125M7Y1B 15,0 − 16 − 11,5 0.094+0.094 0.75+0.75 0,106 1,4
FDA125A5VEB RZAG125M7Y1B 15,7 − 16 − 11,5 0.094+0.094 0.75+0.75 0,350 2,1
FVA125AMVEB RZAG125M7Y1B 14,8 − 16 − 11,5 0.094+0.094 0.75+0.75 0,238 1,2
FDXM35F3V1B x4 RZAG125M7Y1B 12,2 − 16 − 9,0 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4
FDXM50F3V1B x3 RZAG125M7Y1B 13,5 − 16 − 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3
FDXM60F3V1B x2 RZAG125M7Y1B 14,6 − 16 − 11,5 0.094+0.094 0.75+0.75 0.060 x2 0.5 x2
FHA35AVEB x4 RZAG125M7Y1B 13,4 − 16 − 9,0 0.094+0.094 0.75+0.75 0.060 x4 0.6 x4
FHA50AVEB x3 RZAG125M7Y1B 13,8 − 16 − 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.6 x3
FHA60AVEB x2 RZAG125M7Y1B 14,8 − 16 − 11,5 0.094+0.094 0.75+0.75 0.091 x2 0.6 x2
FHA125AVEB RZAG125M7Y1B 15,1 − 16 − 11,5 0.094+0.094 0.75+0.75 0,150 1,5
FCAHG71GVEB x2 RZAG140M7Y1B 14,6 − 16 − 11,5 0.094+0.094 0.75+0.75 0.091 x2 0.5 x2
FCAHG140GVEB RZAG140M7Y1B 15,0 − 16 − 11,5 0.094+0.094 0.75+0.75 0,244 1,4
FCAG35AVEB x4 RZAG140M7Y1B 12,2 − 16 − 9,0 0.094+0.094 0.75+0.75 0.044 x4 0.3 x4
FCAG50AVEB x3 RZAG140M7Y1B 12,9 − 16 − 10,0 0.094+0.094 0.75+0.75 0.039 x3 0.3 x3
FCAG71AVEB x2 RZAG140M7Y1B 14,4 − 16 − 11,5 0.094+0.094 0.75+0.75 0.054 x2 0.4 x2
FCAG140AVEB RZAG140M7Y1B 14,6 − 16 − 11,5 0.094+0.094 0.75+0.75 0,168 1,0
FFA35A2VEB x4 RZAG140M7Y1B 12,6 − 16 − 9,0 0.094+0.094 0.75+0.75 0.050 x4 0.4 x4
FFA50A2VEB x3 RZAG140M7Y1B 13,2 − 16 − 10,0 0.094+0.094 0.75+0.75 0.050 x3 0.4 x3
FBA35A2VEB x4 RZAG140M7Y1B 13,4 − 16 − 9,0 0.094+0.094 0.75+0.75 0.089 x4 0.6 x4
FBA50A2VEB x3 RZAG140M7Y1B 13,8 − 16 − 10,0 0.094+0.094 0.75+0.75 0.089 x3 0.6 x3
Minimum: 342 V

Maximum 456 V

FBA71A2VEB x2 RZAG140M7Y1B 14,6 − 16 − 11,5 0.094+0.094 0.75+0.75 0.070 x2 0.5 x2


FBA140A2VEB RZAG140M7Y1B 3N~ 50Hz 15,1 − 16 − 11,5 0.094+0.094 0.75+0.75 0,187 1,5
FNA35A2VEB x4 RZAG140M7Y1B 380-415V 12,2 − 16 − 9,0 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4
FNA50A2VEB x3 RZAG140M7Y1B 13,5 − 16 − 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3
FUA71AVEB x2 RZAG140M7Y1B 15,4 − 16 − 11,5 0.094+0.094 0.75+0.75 0.046 x2 0.9 x2
FAA71AUVEB x2 RZAG140M7Y1B 14,4 − 16 − 11,5 0.094+0.094 0.75+0.75 0.048 x2 0.4 x2
FVA71AMVEB x2 RZAG140M7Y1B 14,8 − 16 − 11,5 0.094+0.094 0.75+0.75 0.117 x2 0.6 x2
FVA140AMVEB RZAG140M7Y1B 15,0 − 16 − 11,5 0.094+0.094 0.75+0.75 0,276 1,4
FDXM35F3V1B x4 RZAG140M7Y1B 12,2 − 16 − 9,0 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4
FDXM50F3V1B x3 RZAG140M7Y1B 13,5 − 16 − 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3
FHA35AVEB x4 RZAG140M7Y1B 13,4 − 16 − 9,0 0.094+0.094 0.75+0.75 0.060 x4 0.6 x4
FHA50AVEB x3 RZAG140M7Y1B 13,8 − 16 − 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.6 x3
FHA71AVEB x2 RZAG140M7Y1B 15,2 − 16 − 11,5 0.094+0.094 0.75+0.75 0.091 x2 0.8 x2
FHA140AVEB RZAG140M7Y1B 15,4 − 16 − 11,5 0.094+0.094 0.75+0.75 0,150 1,8

3D110014A

204
3D110014A
RZAG-MY1
VIEW ALL RZAG-MV1 TECHNICAL

SKY AIR INTRO


RZASG-MV1
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZASG-MY1
RZAG-MV1/MY1

Symbols
MCA: Minimum Circuit Ampere [A]
TOCA: Total overcurrent amps [A]
MFA: Maximum Fuse Ampere [A]

INDOOR
MSC: Maximum current of the starting compressor [A]

UNITS
RLA: Rated load amps [A]
OFM: Outdoor fan motor
IFM: Indoor fan motor
FLA: Full Load Ampere [A]
KW: Fan motor rated output [kW]

Notes

OUTDOOR
1. The RLA is based on the following conditions.

UNITS
Cooling
Indoor temperature 27.0°C DB / 19.0°C WB
Outdoor temperature 35.0°C DB
Heating
Indoor temperature 20.0°C DB
Outdoor temperature 7.0°C DB / 6.0°C WB
2. TOCA is the total value of each overcurrent set.
3. Voltage range

AIR CURTAINS
The units are suitable for use with electrical systems in which the voltage supplied to the unit terminals is not below or above the listed range limits.

BIDDLE
4. The maximum allowable voltage that is unbalanced between phases is 2%.
5. MCA is the maximum input current.
The capacity of the MFA must be greater than that of the MCA.
Select the MFA according to the table.
6. Select the wire size according to the MCA.
7. MFA is used to select the circuit breaker and the ground fault circuit interruptor.
Earth leakage circuit breaker

VENTILATION
3D110014A

RZAG71-100MV1
RZAG71-100MV1 INFRASTRUCTURE COOLING 3D110014A
Compressor OFM IFM

Voltage

CONTROL
SYSTEMS
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAHG100GVEB RZAG71M7V1B 18,3 − 20 − 15,5 0,094 0,8 0,221 1,3


FCAG35AVEB x3 RZAG71M7V1B 17,9 − 20 − 15,5 0,094 0,8 0.044 x3 0.3 x3
FCAG50AVEB x2 RZAG71M7V1B 17,6 20 15,5 0,094 0,8 0.039 x2 0.3 x2
FCAG100AVEB RZAG71M7V1B 17,7 − 20 − 15,5 0,094 0,8 0,117 0,7
FFA35A2VEB x3 RZAG71M7V1B 18,2 − 20 − 15,5 0,094 0,8 0.050 x3 0.4 x3
FFA50A2VEB x2 RZAG71M7V1B 17,8 − 20 − 15,5 0,094 0,8 0.050 x2 0.4 x2
− −
Minimum: ·198 V·

Maximum ·264 V·

FBA35A2VEB x3 RZAG71M7V1B 18,8 20 15,5 0,094 0,8 0.089 x3 0.6 x3


FBA50A2VEB x2 RZAG71M7V1B 18,2 − 20 − 15,5 0,094 0,8 0.089 x2 0.6 x2
50Hz ~
− −

& ACCESSORIES
FBA100A2VEB RZAG71M7V1B 18,0 20 15,5 0,094 0,8 0,127 1,0
220-240V
FUA100AVEB RZAG71M7V1B 18,3 − 20 − 15,5 0,094 0,8 0,106 1,3

OPTIONS
FAA100AUVEB RZAG71M7V1B 17,4 − 20 − 15,5 0,094 0,8 0,064 0,4
FVA100AMVEB RZAG71M7V1B 18,2 − 20 − 15,5 0,094 0,8 0,238 1,2
FDXM35F3V1B x3 RZAG71M7V1B 17,9 − 20 − 15,5 0,094 0,8 0.034 x3 0.3 x3
FDXM50F3V1B x2 RZAG71M7V1B 18,0 − 20 − 15,5 0,094 0,8 0.060 x2 0.5 x2
FHA35AVEB x3 RZAG71M7V1B 18,8 − 20 − 15,5 0,094 0,8 0.060 x3 0.6 x3
FHA50AVEB x2 RZAG71M7V1B 18,2 − 20 − 15,5 0,094 0,8 0.060 x2 0.6 x2
FHA100AVEB RZAG71M7V1B 18,3 − 20 − 15,5 0,094 0,8 0,150 1,3
FCAHG71GVEB x2 RZAG100M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0.091 x2 0.5 x2
FCAHG140GVEB RZAG100M7V1B 27,5 32 − 23,5 0.094+0.094 0.75+0.75 0,244 1,4
FCAG35AVEB x4 RZAG100M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.044 x4 0.3 x4
FCAG50AVEB x3 RZAG100M7V1B 26,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.039 x3 0.3 x3
& PLATFORMS

FCAG71AVEB x2 RZAG100M7V1B 26,8 32 − 23,5 0.094+0.094 0.75+0.75 0.054 x2 0.4 x2


− −
TOOLS

FCAG140AVEB RZAG100M7V1B 27,0 32 23,5 0.094+0.094 0.75+0.75 0,168 1,0


FFA35A2VEB x4 RZAG100M7V1B 27,7 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x4 0.4 x4
FFA50A2VEB x3 RZAG100M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x3 0.4 x3
− −
Minimum: ·198 V·

Maximum ·264 V·

FBA35A2VEB x4 RZAG100M7V1B 28,5 32 23,5 0.094+0.094 0.75+0.75 0.089 x4 0.6 x4


FBA50A2VEB x3 RZAG100M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.089 x3 0.6 x3
50Hz ~
FBA71A2VEB x2 RZAG100M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0.07 x2 0.5 x2
220-240V
FBA140A2VEB RZAG100M7V1B 27,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0,187 1,5
FUA71AVEB x2 RZAG100M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.046 x2 0.9 x2
FAA71AUVEB x2 RZAG100M7V1B 26,8 − 32 − 23,5 0.094+0.094 0.75+0.75 0.048 x2 0.4 x2
FVA140AMVEB RZAG100M7V1B 27,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0,276 1,4
FDXM35F3V1B x4 RZAG100M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4
− −
TECHNICAL

FDXM50F3V1B x3 RZAG100M7V1B 27,6 32 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3


DRAWINGS

FHA35AVEB x4 RZAG100M7V1B 28,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x4 0.6 x4


FHA50AVEB x3 RZAG100M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.6 x3
FHA71AVEB x2 RZAG100M7V1B 27,7 − 32 − 23,5 0.094+0.094 0.75+0.75 0.091 x2 0.8 x2
FHA140AVEB RZAG100M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0,150 1,8

3D110015A
3D110014A
PREVIOUS

205
VIEW ALL RZAG-MY1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZAG125-140MV1
RZAG125-140MV1 INFRASTRUCTURE COOLING
Compressor OFM IFM

Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAHG71GVEB x2 RZAG125M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0.091 x2 0.5 x2


FCAHG140GVEB RZAG125M7V1B 27,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0,244 1,4
FCAG35AVEB x4 RZAG125M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.044 x4 0.3 x4
FCAG50AVEB x3 RZAG125M7V1B 26,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.039 x3 0.3 x3
FCAG71AVEB x2 RZAG125M7V1B 26,8 − 32 − 23,5 0.094+0.094 0.75+0.75 0.054 x2 0.4 x2
FCAG140AVEB RZAG125M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0,168 1,0
FFA35A2VEB x4 RZAG125M7V1B 27,7 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x4 0.4 x4
FFA50A2VEB x3 RZAG125M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x3 0.4 x3
− −

Minimum: ·198 V·

Maximum ·264 V·
FBA35A2VEB x4 RZAG125M7V1B 28,5 32 23,5 0.094+0.094 0.75+0.75 0.089 x4 0.6 x4
FBA50A2VEB x3 RZAG125M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.089 x3 0.6 x3
50Hz ~
FBA71A2VEB x2 RZAG125M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0.07 x2 0.5 x2
220-240V
FBA140A2VEB RZAG125M7V1B 27,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0,187 1,5
FUA71AVEB x2 RZAG125M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.046 x2 0.9 x2
FAA71AUVEB x2 RZAG125M7V1B 26,8 − 32 − 23,5 0.094+0.094 0.75+0.75 0.048 x2 0.4 x2
FVA140AMVEB RZAG125M7V1B 27,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0,276 1,4
FDXM35F3V1B x4 RZAG125M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4
FDXM50F3V1B x3 RZAG125M7V1B 27,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3
FHA35AVEB x4 RZAG125M7V1B 28,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x4 0.6 x4
FHA50AVEB x3 RZAG125M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.6 x3
FHA71AVEB x2 RZAG125M7V1B 27,7 − 32 − 23,5 0.094+0.094 0.75+0.75 0.091 x2 0.8 x2
FHA140AVEB RZAG125M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0,150 1,8
FCAHG71GVEB x2 RZAG140M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0.091 x2 0.5 x2
FCAHG140GVEB RZAG140M7V1B 27,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0,244 1,4
FCAG35AVEB x4 RZAG140M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.044 x4 0.3 x4
FCAG50AVEB x3 RZAG140M7V1B 26,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.039 x3 0.3 x3
FCAG71AVEB x2 RZAG140M7V1B 26,8 − 32 − 23,5 0.094+0.094 0.75+0.75 0.054 x2 0.4 x2
FCAG140AVEB RZAG140M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0,168 1,0
FFA35A2VEB x4 RZAG140M7V1B 27,7 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x4 0.4 x4
FFA50A2VEB x3 RZAG140M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.050 x3 0.4 x3
− −
Minimum: ·198 V·

Maximum ·264 V·

FBA35A2VEB x4 RZAG140M7V1B 28,5 32 23,5 0.094+0.094 0.75+0.75 0.089 x4 0.6 x4


FBA50A2VEB x3 RZAG140M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.089 x3 0.6 x3
50Hz ~
FBA71A2VEB x2 RZAG140M7V1B 27,0 − 32 − 23,5 0.094+0.094 0.75+0.75 0.07 x2 0.5 x2
220-240V
FBA140A2VEB RZAG140M7V1B 27,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0,187 1,5
FUA71AVEB x2 RZAG140M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.046 x2 0.9 x2
FAA71AUVEB x2 RZAG140M7V1B 26,8 − 32 − 23,5 0.094+0.094 0.75+0.75 0.048 x2 0.4 x2
FVA140AMVEB RZAG140M7V1B 27,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0,276 1,4
FDXM35F3V1B x4 RZAG140M7V1B 27,2 − 32 − 23,5 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4
FDXM50F3V1B x3 RZAG140M7V1B 27,6 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3
FHA35AVEB x4 RZAG140M7V1B 28,5 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x4 0.6 x4
FHA50AVEB x3 RZAG140M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0.060 x3 0.6 x3
FHA71AVEB x2 RZAG140M7V1B 27,7 − 32 − 23,5 0.094+0.094 0.75+0.75 0.091 x2 0.8 x2
FHA140AVEB RZAG140M7V1B 27,9 − 32 − 23,5 0.094+0.094 0.75+0.75 0,150 1,8

3D110015A
RZAG71-100MY1 3D110015A
RZAG71-100MY1
Compressor OFM IFM

Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAHG100GVEB RZAG71M7Y1B 11,8 − 16 − 9,2 0,094 0,8 0,221 1,3


FCAG35AVEB x3 RZAG71M7Y1B 11,3 − 16 − 9,2 0,094 0,8 0.044 x3 0.3 x3
FCAG50AVEB x2 RZAG71M7Y1B 11,0 − 16 − 9,2 0,094 0,8 0.039 x2 0.3 x2
FCAG100AVEB RZAG71M7Y1B 11,1 − 16 − 9,2 0,094 0,8 0,117 0,7
FFA35A2VEB x3 RZAG71M7Y1B 11,6 − 16 − 9,2 0,094 0,8 0.050 x3 0.4 x3
FFA50A2VEB x2 RZAG71M7Y1B 11,2 − 16 − 9,2 0,094 0,8 0.050 x2 0.4 x2
− −
Minimum: ·342 V·

Maximum ·456 V·

FBA35A2VEB x3 RZAG71M7Y1B 12,3 16 9,2 0,094 0,8 0.089 x3 0.6 x3


FBA50A2VEB x2 RZAG71M7Y1B 11,6 − 16 − 9,2 0,094 0,8 0.089 x2 0.6 x2
3N~ 50Hz
FBA100A2VEB RZAG71M7Y1B 11,4 − 16 − 9,2 0,094 0,8 0,127 1,0
380-415V
FUA100AVEB RZAG71M7Y1B 11,8 − 16 − 9,2 0,094 0,8 0,106 1,3
FAA100AUVEB RZAG71M7Y1B 10,8 − 16 − 9,2 0,094 0,8 0,064 0,4
FVA100AMVEB RZAG71M7Y1B 11,6 − 16 − 9,2 0,094 0,8 0,238 1,2
FDXM35F3V1B x3 RZAG71M7Y1B 11,3 − 16 − 9,2 0,094 0,8 0.034 x3 0.3 x3
FDXM50F3V1B x2 RZAG71M7Y1B 11,4 − 16 − 9,2 0,094 0,8 0.060 x2 0.5 x2
FHA35AVEB x3 RZAG71M7Y1B 12,3 − 16 − 9,2 0,094 0,8 0.060 x3 0.6 x3
FHA50AVEB x2 RZAG71M7Y1B 11,6 − 16 − 9,2 0,094 0,8 0.060 x2 0.6 x2
FHA100AVEB RZAG71M7Y1B 11,8 − 16 − 9,2 0,094 0,8 0,150 1,3
FCAHG71GVEB x2 RZAG100M7Y1B 14,0 − 16 − 11,0 0.094+0.094 0.75+0.75 0.091 x2 0.5 x2
FCAHG140GVEB RZAG100M7Y1B 15,5 − 16 − 12,0 0.094+0.094 0.75+0.75 0,244 1,4
FCAG35AVEB x4 RZAG100M7Y1B 13,2 − 16 − 10,0 0.094+0.094 0.75+0.75 0.044 x4 0.3 x4
FCAG50AVEB x3 RZAG100M7Y1B 12,9 − 16 − 10,0 0.094+0.094 0.75+0.75 0.039 x3 0.3 x3
FCAG71AVEB x2 RZAG100M7Y1B 13,8 − 16 − 11,0 0.094+0.094 0.75+0.75 0.054 x2 0.4 x2
FCAG140AVEB RZAG100M7Y1B 15,1 − 16 − 12,0 0.094+0.094 0.75+0.75 0,168 1,0
FFA35A2VEB x4 RZAG100M7Y1B 13,6 − 16 − 10,0 0.094+0.094 0.75+0.75 0.050 x4 0.4 x4
FFA50A2VEB x3 RZAG100M7Y1B 13,2 − 16 − 10,0 0.094+0.094 0.75+0.75 0.050 x3 0.4 x3
− −
Minimum: ·342 V·

Maximum ·456 V·

FBA35A2VEB x4 RZAG100M7Y1B 14,5 16 10,0 0.094+0.094 0.75+0.75 0.089 x4 0.6 x4


FBA50A2VEB x3 RZAG100M7Y1B 13,8 − 16 − 10,0 0.094+0.094 0.75+0.75 0.089 x3 0.6 x3
3N~ 50Hz
FBA71A2VEB x2 RZAG100M7Y1B 14,0 − 16 − 11,0 0.094+0.094 0.75+0.75 0.07 x2 0.5 x2
380-415V
FBA140A2VEB RZAG100M7Y1B 15,6 − 16 − 12,0 0.094+0.094 0.75+0.75 0,187 1,5
FUA71AVEB x2 RZAG100M7Y1B 14,9 − 16 − 11,0 0.094+0.094 0.75+0.75 0.046 x2 0.9 x2
FAA71AUVEB x2 RZAG100M7Y1B 13,8 − 16 − 11,0 0.094+0.094 0.75+0.75 0.048 x2 0.4 x2
FVA140AMVEB RZAG100M7Y1B 15,5 − 16 − 12,0 0.094+0.094 0.75+0.75 0,276 1,4
FDXM35F3V1B x4 RZAG100M7Y1B 13,2 − 16 − 10,0 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4
FDXM50F3V1B x3 RZAG100M7Y1B 13,5 − 16 − 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3
FHA35AVEB x4 RZAG100M7Y1B 14,5 − 16 − 10,0 0.094+0.094 0.75+0.75 0.060 x4 0.6 x4
FHA50AVEB x3 RZAG100M7Y1B 13,8 − 16 − 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.6 x3
FHA71AVEB x2 RZAG100M7Y1B 14,7 − 16 − 11,0 0.094+0.094 0.75+0.75 0.091 x2 0.8 x2
FHA140AVEB RZAG100M7Y1B 15,9 − 16 − 12,0 0.094+0.094 0.75+0.75 0,150 1,8

3D110015A
3D110015A

206
VIEW ALL RZAG-MV1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZAG125-140MY1
RZAG125-140MY1 INFRASTRUCTURE COOLING
Compressor OFM IFM

Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAHG71GVEB x2 RZAG125M7Y1B 14,6 − 16 11,5 0.094+0.094 0.75+0.75 0.091 x2 0.5 x2


INDOOR
FCAHG140GVEB RZAG125M7Y1B 15,0 16 11,5 0.094+0.094 0.75+0.75 0,244 1,4

UNITS
FCAG35AVEB x4 RZAG125M7Y1B 12,2 − 16 9,0 0.094+0.094 0.75+0.75 0.044 x4 0.3 x4
FCAG50AVEB x3 RZAG125M7Y1B 12,9 − 16 10,0 0.094+0.094 0.75+0.75 0.039 x3 0.3 x3
FCAG71AVEB x2 RZAG125M7Y1B 14,4 − 16 11,5 0.094+0.094 0.75+0.75 0.054 x2 0.4 x2
FCAG140AVEB RZAG125M7Y1B 14,6 − 16 11,5 0.094+0.094 0.75+0.75 0,168 1,0
FFA35A2VEB x4 RZAG125M7Y1B 12,6 − 16 9,0 0.094+0.094 0.75+0.75 0.050 x4 0.4 x4
FFA50A2VEB x3 RZAG125M7Y1B 13,2 − 16 10,0 0.094+0.094 0.75+0.75 0.050 x3 0.4 x3

Minimum: ·342 V·

Maximum ·456 V·
FBA35A2VEB x4 RZAG125M7Y1B 13,4 16 9,0 0.094+0.094 0.75+0.75 0.089 x4 0.6 x4
FBA50A2VEB x3 RZAG125M7Y1B 13,8 − 16 10,0 0.094+0.094 0.75+0.75 0.089 x3 0.6 x3
3N~ 50Hz
FBA71A2VEB x2 RZAG125M7Y1B 14,6 − 16 11,5 0.094+0.094 0.75+0.75 0.07 x2 0.5 x2
380-415V
FBA140A2VEB RZAG125M7Y1B 15,1 − 16 11,5 0.094+0.094 0.75+0.75 0,187 1,5
FUA71AVEB x2 RZAG125M7Y1B 15,4 − 16 11,5 0.094+0.094 0.75+0.75 0.046 x2 0.9 x2

OUTDOOR
FAA71AUVEB x2 RZAG125M7Y1B 14,4 − 16 11,5 0.094+0.094 0.75+0.75 0.048 x2 0.4 x2

UNITS
FVA140AMVEB RZAG125M7Y1B 15,0 − 16 11,5 0.094+0.094 0.75+0.75 0,276 1,4
FDXM35F3V1B x4 RZAG125M7Y1B 12,2 − 16 9,0 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4
FDXM50F3V1B x3 RZAG125M7Y1B 13,5 − 16 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3
FHA35AVEB x4 RZAG125M7Y1B 13,4 − 16 9,0 0.094+0.094 0.75+0.75 0.060 x4 0.6 x4
FHA50AVEB x3 RZAG125M7Y1B 13,8 − 16 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.6 x3
FHA71AVEB x2 RZAG125M7Y1B 15,2 − 16 11,5 0.094+0.094 0.75+0.75 0.091 x2 0.8 x2
FHA140AVEB RZAG125M7Y1B 15,4 − 16 11,5 0.094+0.094 0.75+0.75 0,150 1,8
FCAHG71GVEB x2 RZAG140M7Y1B 14,6 − 16 11,5 0.094+0.094 0.75+0.75 0.091 x2 0.5 x2
FCAHG140GVEB RZAG140M7Y1B 15,0 − 16 11,5 0.094+0.094 0.75+0.75 0,244 1,4
FCAG35AVEB x4 RZAG140M7Y1B 12,2 − 16 9,0 0.094+0.094 0.75+0.75 0.044 x4 0.3 x4

AIR CURTAINS
FCAG50AVEB x3 RZAG140M7Y1B 12,9 16 10,0 0.094+0.094 0.75+0.75 0.039 x3 0.3 x3
FCAG71AVEB x2 RZAG140M7Y1B 14,4 − 16 11,5 0.094+0.094 0.75+0.75 0.054 x2 0.4 x2

BIDDLE
FCAG140AVEB RZAG140M7Y1B 14,6 − 16 11,5 0.094+0.094 0.75+0.75 0,168 1,0
FFA35A2VEB x4 RZAG140M7Y1B 12,6 − 16 9,0 0.094+0.094 0.75+0.75 0.050 x4 0.4 x4
FFA50A2VEB x3 RZAG140M7Y1B 13,2 − 16 10,0 0.094+0.094 0.75+0.75 0.050 x3 0.4 x3

Minimum: ·342 V·

Maximum ·456 V·

FBA35A2VEB x4 RZAG140M7Y1B 13,4 16 9,0 0.094+0.094 0.75+0.75 0.089 x4 0.6 x4


FBA50A2VEB x3 RZAG140M7Y1B 13,8 − 16 10,0 0.094+0.094 0.75+0.75 0.089 x3 0.6 x3
3N~ 50Hz
FBA71A2VEB x2 RZAG140M7Y1B 14,6 − 16 11,5 0.094+0.094 0.75+0.75 0.07 x2 0.5 x2
380-415V
FBA140A2VEB RZAG140M7Y1B 15,1 − 16 11,5 0.094+0.094 0.75+0.75 0,187 1,5
FUA71AVEB x2 RZAG140M7Y1B 15,4 − 16 11,5 0.094+0.094 0.75+0.75 0.046 x2 0.9 x2
FAA71AUVEB x2 RZAG140M7Y1B 14,4 − 16 11,5 0.094+0.094 0.75+0.75 0.048 x2 0.4 x2
FVA140AMVEB RZAG140M7Y1B 15,0 − 16 11,5 0.094+0.094 0.75+0.75 0,276 1,4
FDXM35F3V1B x4 RZAG140M7Y1B 12,2 − 16 9,0 0.094+0.094 0.75+0.75 0.034 x4 0.3 x4

VENTILATION
FDXM50F3V1B x3 RZAG140M7Y1B 13,5 − 16 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.5 x3
FHA35AVEB x4 RZAG140M7Y1B 13,4 − 16 9,0 0.094+0.094 0.75+0.75 0.060 x4 0.6 x4
FHA50AVEB x3 RZAG140M7Y1B 13,8 − 16 10,0 0.094+0.094 0.75+0.75 0.060 x3 0.6 x3
FHA71AVEB x2 RZAG140M7Y1B 15,2 − 16 11,5 0.094+0.094 0.75+0.75 0.091 x2 0.8 x2
FHA140AVEB RZAG140M7Y1B 15,4 − 16 11,5 0.094+0.094 0.75+0.75 0,150 1,8

RZASG71-100MV1 3D110015A
3D110015A

RZASG71-100MV1

CONTROL
SYSTEMS
Compressor OFM IFM

Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAG35AVEB x2 RZASG71M2V1B 17,6 − 20 − 15,4 0,094 0,9 0.044 x2 0.3 x2


FCAG71AVEB RZASG71M2V1B 17,4 − 20 − 15,4 0,094 0,9 0,054 0,4
FFA35A2VEB x2 RZASG71M2V1B 17,8 − 20 − 15,4 0,094 0,9 0.050 x2 0.4 x2
FBA35A2VEB x2 RZASG71M2V1B 18,2 − 20 − 15,4 0,094 0,9 0.089 x2 0.6 x2
Minimum: 198 V

Maximum 264 V

& ACCESSORIES
FBA71A2VEB RZASG71M2V1B 17,5 − 20 − 15,4 0,094 0,9 0,070 0,5
50Hz ~ − −

OPTIONS
FNA35A2VEB x2 RZASG71M2V1B 17,3 20 15,4 0,094 0,9 0.034 x2 0,3
FUA71AVEB RZASG71M2V1B 220-240V 17,9 − 20 − 15,4 0,094 0,9 0,046 0,9
FAA71AUVEB RZASG71M2V1B 17,4 − 20 − 15,4 0,094 0,9 0,048 0,4
FVA71AMVEB RZASG71M2V1B 17,6 − 20 − 15,4 0,094 0,9 0,117 0,6
FDXM35F3V1B x2 RZASG71M2V1B 17,6 − 20 − 15,4 0,094 0,9 0.034 x2 0.3 x2
FHA35AVEB x2 RZASG71M2V1B 18,2 − 20 − 15,4 0,094 0,9 0.060 x2 0.6 x2
FHA71AVEB RZASG71M2V1B 17,8 − 20 − 15,4 0,094 0,9 0,091 0,8
FCAG35AVEB x3 RZASG100M7V1B 21,7 − 25 − 19,0 0,200 1,0 0.044 x3 0.3 x3
FCAG50AVEB x2 RZASG100M7V1B 21,4 − 25 − 19,0 0,200 1,0 0.039 x2 0.3 x2
FCAG100AVEB RZASG100M7V1B 21,5 − 25 − 19,0 0,200 1,0 0,117 0,7
FFA35A2VEB x3 RZASG100M7V1B 22,0 − 25 − 19,0 0,200 1,0 0.050 x3 0.4 x3
FFA50A2VEB x2 RZASG100M7V1B 21,6 − 25 − 19,0 0,200 1,0 0.050 x2 0.4 x2
& PLATFORMS

FBA100A2VEB RZASG100M7V1B 21,8 − 25 − 19,0 0,200 1,0 0,127 1,0


Minimum: 198 V

Maximum 264 V

− −
TOOLS

FNA35A2VEB x3 RZASG100M7V1B 21,7 25 19,0 0,200 1,0 0.034 x3 0.3 x3


FNA50A2VEB x2 RZASG100M7V1B 50Hz ~ 21,8 − 25 − 19,0 0,200 1,0 0.060 x2 0.5 x2
FUA100AVEB RZASG100M7V1B 220-240V 22,2 − 25 − 19,0 0,200 1,0 0,106 1,3
FAA100AUVEB RZASG100M7V1B 21,2 − 25 − 19,0 0,200 1,0 0,064 0,4
FVA100AMVEB RZASG100M7V1B 22,0 − 25 − 19,0 0,200 1,0 0,238 1,2
FDXM35F3V1B x3 RZASG100M7V1B 21,7 − 25 − 19,0 0,200 1,0 0.034 x3 0.3 x3
FDXM50F3V1B x2 RZASG100M7V1B 21,8 − 25 − 19,0 0,200 1,0 0.060 x2 0.5 x2
FHA35AVEB x3 RZASG100M7V1B 22,7 − 25 − 19,0 0,200 1,0 0.060 x3 0.6 x3
FHA50AVEB x2 RZASG100M7V1B 22,0 − 25 − 19,0 0,200 1,0 0.060 x2 0.6 x2
FHA100AVEB RZASG100M7V1B 22,2 − 25 − 19,0 0,200 1,0 0,150 1,3
TECHNICAL
DRAWINGS

3D110014A

3D110014A
PREVIOUS

207
VIEW ALL RZAG-MY1 TECHNICAL
RZAG-MV1 DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZAG-MY1
RZAG-MY1

Symbols
MCA: Minimum Circuit Ampere [A]
TOCA: Total overcurrent amps [A]
MFA: Maximum Fuse Ampere [A]
MSC: Maximum current of the starting compressor [A]
RLA: Rated load amps [A]
OFM: Outdoor fan motor
IFM: Indoor fan motor
FLA: Full Load Ampere [A]
KW: Fan motor rated output [kW]

Notes
1. The ·RLA· is based on the following conditions.
Cooling
Indoor temperature ·27.0·°C DB / ·19.0·°C WB
Outdoor temperature ·35.0·°C DB
Heating
Indoor temperature ·20.0·°C DB
Outdoor temperature ·7.0·°C DB / ·6.0·°C WB
2. ·TOCA· is the total value of each overcurrent set.
3. Voltage range
The units are suitable for use with electrical systems in which the voltage supplied to the unit terminals is not below or above the listed range limits.
4. The maximum allowable voltage that is unbalanced between phases is ·2·%.
5. ·MCA· is the maximum input current.
The capacity of the ·MFA· must be greater than that of the ·MCA·.
Select the ·MFA· according to the table.
6. Select the wire size according to the MCA.
7. ·MFA· is used to select the circuit breaker and the ground fault circuit interruptor.
Earth leakage circuit breaker
3D110015A

3D110015A

208
RZAG71MV1
VIEW ALL RZAG-MV1 TECHNICAL

SKY AIR INTRO


RZAG71MY1
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZASG100-140MV1
RZAG71-MV1/MY1
RZASG-MY1
4 holes for anchor bolts
160 620 160
M12

30
Model
(340~350)
AA AB

320
345

INDOOR
RZAG71* / RZASG100-125* / AZAS100-125* 331 337

52

UNITS
37
RZASG140* / AZAS140* 414 420

30
37

91

4
32 940
3

OUTDOOR
7

UNITS
7
6
6
5
990

55
60

55
AA
AB

223
95

95

95
88

84
89 19 19 80
53

52
53

53
28

145

AIR CURTAINS
142 13
67

BIDDLE
8 5 71 1 Gas pipe connection Ø15.9 flare
16

2 Liquid pipe connection Ø9.5 flare


16

58

3 Service port (in the unit)

4 Electronic connection and grounding terminal M5 (in the switch box)


99

5 Refrigerant piping intake


6
19

36

39

VENTILATION
32
6 Power supply wiring intake (knockout hole Ø34)
191 154 179
7 Control wiring intake (knockout hole Ø27)

8 Drain outlet
3D110011

RZAG100-140MV1
3D110011
RZAG100-140MY1
RZAG100-140MV1/MY1

CONTROL
SYSTEMS
4 holes for anchor bolts

160 620 160


M12
30
(340∼350)

320
345

52
37

& ACCESSORIES
37
30

OPTIONS
91

32 940

1
& PLATFORMS

7
1430

7
6
TOOLS

6
5
5
55
420
60

414

55

223
95

95

95
88

84

53
53

19 80
28

89 19
53

52
145 13
142
67
5 71
8
TECHNICAL
DRAWINGS

16
1 Gas pipe connection Ø15.9 flare
16

58

2 Liquid pipe connection Ø9.5 flare


99

3 Service port (in the unit)


19

4 Electronic connection and grounding terminal M5 (in the switch box)


6
36

39
32 5 Refrigerant piping intake
191 154 179
6 Power supply wiring intake (knockout hole Ø34)
Control wiring intake (knockout hole Ø27)
PREVIOUS

8 Drain outlet 3D110012

209
RZAG-MV1
RZAG-MY1 VIEW ALL RZAG-MY1 TECHNICAL
RZASG-MV1 DRAWINGS ON MY.DAIKIN.EU
RZASG-MY1
Detailed technical drawings
AZAS-MV1
RZAG-MV1/MY1
AZAS-MY1

210
RZAG-MV1
VIEW ALL RZAG-MV1 TECHNICAL
RZAG-MY1

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
RZASG-MV1 Detailed technical drawings
RZASG-MY1
RZAG-MV1/MY1
AZAS-MV1
AZAS-MY1

INDOOR
UNITS
OUTDOOR
UNITS
AIR CURTAINS
BIDDLE
VENTILATION
CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

211
VIEW ALL RZAG-MY1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZAG-MV1/MY1
RZAG-MV1/MY1

To determine if adding additional refrigerant is necessary

If Then In case of standard liquid pipe size:


(L1+L2+L3+L4+L5+L6+L7)≤ You do not have to add Length
chargeless length additional refrigerant.
0~10 m 10~20 m 20~30 m 30~40 m 40~45 m
Chargeless length= R1: 0.35 kg 0.7 kg 1.05 kg (a)
1.4 kg(a)
▪ 10 m (size-down) R2: 0.2 kg 0.4 kg 0.6 kg 0.8 kg(a) 1 kg(b)
▪ 40 m (standard) In case of size-up liquid pipe size:
▪ 15 m (size-up) Length
(L1+L2+L3+L4+L5+L6+L7)> You must add additional 0~5 m 5~10 10~15 15~20 20~30 30~40 40~45
chargeless length refrigerant. m m(a) m(a) m m m
For future servicing, encircle the R1: 0.35 kg 0.7 kg 1.05 kg 1.4 kg — — —
selected amount in the tables R2: 0.35 kg 0.7 kg 1.05 kg 1.4 kg —
below.
(a) Only for RZAG100~140.
(b) Only for RZAG125-140.
INFORMATION
3 Determine the additional refrigerant amount: R=R1+R2.
Piping length is the largest one way length of liquid piping.
Examples
To determine the additional refrigerant amount (R in kg) (in
case of pair) Layout Additional refrigerant amount (R)
Standard piping size: L2=7 m Case: Twin, standard liquid pipe size
(Ø6.4 mm)
1 G1 Total Ø9.5 => G1=45 m
L1 (m) L3=5 m
(Ø6.4 mm) G2 Total Ø6.4 => G2=7+5=12 m
L1 (standard): 40~50 m 50~55 m 55~60 m 60~75 m 75~85 m 2 Case: G1>40 m
(a) (a) (a)
L1=45 m (Ø9.5 mm)
R1 Length=G1−40 m=5 m
R: 0.35 kg 0.7 kg(a) 0.7 kg 1.05 kg 1.55 kg RZAG100
=> R1=0.35 kg
0.55 kg(b) R2 Length=G2=12 m
(a) Only for RZAG100~140. => R2=0.4 kg
(b) Only for RZAG71.
3 R R=R1+R2=0.35+0.4=0.75 kg
Size-up piping size:
L2=20 m Case: Triple, standard liquid pipe size
L1 (m) (Ø6.4 mm)
1 G1 Total Ø9.5 => G1=15 m
L3=17 m
(Ø6.4 mm) G2 Total Ø6.4 => G2=20+17+17=54 m
L1 (size-up): 15~20 m 20~25 m 25~30 m (a)
30~35 m (a)

L4=17 m 2 Case: G1≤40 m (and G1+G2>40 m)


R: 0.35 kg 0.7 kg 1.05 kg 1.4 kg (Ø6.4 mm)
R1 R1=0.0 kg
(a) Only for RZAG100~140.
L1=15 m (Ø9.5 mm)
R2 Length=G1+G2−40 m=15+54−40=2
To determine the additional refrigerant amount (R in kg) (in 9m
RZAG125
case of twin, triple and double twin)
=> R2=0.6 kg
1 Determine G1 and G2.
3 R R=R1+R2=0.0+0.6=0.6 kg
G1 (m) Total length of <x> liquid piping
x=Ø9.5 mm (standard)
x=Ø12.7 mm (size-up)
G2 (m) Total length of Ø6.4 mm liquid piping

2 Determine R1 and R2.

If Then
G1>40 m(a) Use the table below to determine
R1 (length=G1−40 m)(a) and R2
(length=G2).
G1≤40 m(a) R1=0.0 kg.
(and G1+G2>40 m) (a)
Use the table below to determine
R2 (length=G1+G2−40 m)(a).
(a) In case of size-up: Replace 40 m by 15 m.

4P485927-1 – 2017.04

212
RZASG71-100MV1
VIEW ALL RZASG-MV1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZASG71-100MV1
Compressor OFM IFM

Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAG35AVEB x2 RZASG71M2V1B 17,6 − 20 − 15,4 0,094 0,9 0.044 x2 0.3 x2


FCAG71AVEB RZASG71M2V1B 17,4 − 20 − 15,4 0,094 0,9 0,054 0,4

INDOOR
− −

UNITS
FFA35A2VEB x2 RZASG71M2V1B 17,8 20 15,4 0,094 0,9 0.050 x2 0.4 x2
FBA35A2VEB x2 RZASG71M2V1B 18,2 − 20 − 15,4 0,094 0,9 0.089 x2 0.6 x2

Minimum: 198 V

Maximum 264 V
FBA71A2VEB RZASG71M2V1B 17,5 − 20 − 15,4 0,094 0,9 0,070 0,5
FNA35A2VEB x2 RZASG71M2V1B 50Hz ~ 17,3 − 20 − 15,4 0,094 0,9 0.034 x2 0,3
FUA71AVEB RZASG71M2V1B 220-240V 17,9 − 20 − 15,4 0,094 0,9 0,046 0,9
FAA71AUVEB RZASG71M2V1B 17,4 − 20 − 15,4 0,094 0,9 0,048 0,4
FVA71AMVEB RZASG71M2V1B 17,6 − 20 − 15,4 0,094 0,9 0,117 0,6
FDXM35F3V1B x2 RZASG71M2V1B 17,6 − 20 − 15,4 0,094 0,9 0.034 x2 0.3 x2
FHA35AVEB x2 RZASG71M2V1B 18,2 − 20 − 15,4 0,094 0,9 0.060 x2 0.6 x2
FHA71AVEB RZASG71M2V1B 17,8 − 20 − 15,4 0,094 0,9 0,091 0,8
FCAG35AVEB x3 RZASG100M7V1B 21,7 − 25 − 19,0 0,200 1,0 0.044 x3 0.3 x3
− −

OUTDOOR
FCAG50AVEB x2 RZASG100M7V1B 21,4 25 19,0 0,200 1,0 0.039 x2 0.3 x2
− −

UNITS
FCAG100AVEB RZASG100M7V1B 21,5 25 19,0 0,200 1,0 0,117 0,7
FFA35A2VEB x3 RZASG100M7V1B 22,0 − 25 − 19,0 0,200 1,0 0.050 x3 0.4 x3
FFA50A2VEB x2 RZASG100M7V1B 21,6 − 25 − 19,0 0,200 1,0 0.050 x2 0.4 x2
FBA100A2VEB RZASG100M7V1B 21,8 − 25 − 19,0 0,200 1,0 0,127 1,0
Minimum: 198 V

Maximum 264 V
FNA35A2VEB x3 RZASG100M7V1B 21,7 − 25 − 19,0 0,200 1,0 0.034 x3 0.3 x3
FNA50A2VEB x2 RZASG100M7V1B 50Hz ~ 21,8 − 25 − 19,0 0,200 1,0 0.060 x2 0.5 x2
FUA100AVEB RZASG100M7V1B 220-240V 22,2 − 25 − 19,0 0,200 1,0 0,106 1,3
FAA100AUVEB RZASG100M7V1B 21,2 − 25 − 19,0 0,200 1,0 0,064 0,4
FVA100AMVEB RZASG100M7V1B 22,0 − 25 − 19,0 0,200 1,0 0,238 1,2
FDXM35F3V1B x3 RZASG100M7V1B 21,7 − 25 − 19,0 0,200 1,0 0.034 x3 0.3 x3
FDXM50F3V1B x2 RZASG100M7V1B 21,8 − 25 − 19,0 0,200 1,0 0.060 x2 0.5 x2

AIR CURTAINS
FHA35AVEB x3 RZASG100M7V1B 22,7 − 25 − 19,0 0,200 1,0 0.060 x3 0.6 x3
− −

BIDDLE
FHA50AVEB x2 RZASG100M7V1B 22,0 25 19,0 0,200 1,0 0.060 x2 0.6 x2
FHA100AVEB RZASG100M7V1B 22,2 − 25 − 19,0 0,200 1,0 0,150 1,3

3D110014A

VENTILATION
RZASG125-140MV1
RZASG125-140MV1
Compressor OFM
3D110014A IFM

Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAG35AVEB x4 RZASG125M7V1B 28,0 − 32 − 24,7 0,200 1,0 0.044 x4 0.3 x4


FCAG50AVEB x3 RZASG125M7V1B 27,7 − 32 − 24,7 0,200 1,0 0.039 x3 0.3 x3
FCAG60AVEB x2 RZASG125M7V1B 27,4 − 32 − 24,7 0,200 1,0 0.044 x2 0.3 x2

CONTROL
SYSTEMS
FCAG125AVEB RZASG125M7V1B 27,8 − 32 − 24,7 0,200 1,0 0,168 1,0
FFA35A2VEB x4 RZASG125M7V1B 28,4 − 32 − 24,7 0,200 1,0 0.050 x4 0.4 x4
FFA50A2VEB x3 RZASG125M7V1B 28,0 − 32 − 24,7 0,200 1,0 0.050 x3 0.4 x3
FFA60A2VEB x2 RZASG125M7V1B 28,0 − 32 − 24,7 0,200 1,0 0.050 x2 0.6 x2
FBA35A2VEB x4 RZASG125M7V1B 29,2 − 32 − 24,7 0,200 1,0 0.089 x4 0.6 x4
FBA50A2VEB x3 RZASG125M7V1B 28,6 − 32 − 24,7 0,200 1,0 0.089 x3 0.6 x3
FBA60A2VEB x2 RZASG125M7V1B 27,8 − 32 − 24,7 0,200 1,0 0.070 x2 0.5 x2
Minimum: 198 V

Maximum 264 V

FBA125A2VEB RZASG125M7V1B 28,3 − 32 − 24,7 0,200 1,0 0,187 1,5


FNA35A2VEB x4 RZASG125M7V1B 50Hz ~ 28,0 − 32 − 24,7 0,200 1,0 0.034 x4 0.3 x4
FNA50A2VEB x3 RZASG125M7V1B 220-240V 28,3 − 32 − 24,7 0,200 1,0 0.060 x3 0.5 x3

& ACCESSORIES
FNA60A2VEB x2 RZASG125M7V1B 27,8 − 32 − 24,7 0,200 1,0 0.060 x2 0.5 x2
− −

OPTIONS
FUA125AVEB RZASG125M7V1B 28,2 32 24,7 0,200 1,0 0,106 1,4
FDA125A5VEB RZASG125M7V1B 28,9 − 32 − 24,7 0,200 1,0 0,350 2,1
FVA125AMVEB RZASG125M7V1B 28,0 − 32 − 24,7 0,200 1,0 0,238 1,2
FDXM35F3V1B x4 RZASG125M7V1B 28,0 − 32 − 24,7 0,200 1,0 0.034 x4 0.3 x4
FDXM50F3V1B x3 RZASG125M7V1B 28,3 − 32 − 24,7 0,200 1,0 0.060 x3 0.5 x3
FDXM60F3V1B x2 RZASG125M7V1B 27,8 − 32 − 24,7 0,200 1,0 0.060 x2 0.5 x2
FHA35AVEB x4 RZASG125M7V1B 29,2 − 32 − 24,7 0,200 1,0 0.060 x4 0.6 x4
FHA50AVEB x3 RZASG125M7V1B 28,6 − 32 − 24,7 0,200 1,0 0.060 x3 0.6 x3
FHA60AVEB x2 RZASG125M7V1B 28,0 − 32 − 24,7 0,200 1,0 0.091 x2 0.6 x2
FHA125AVEB RZASG125M7V1B 28,3 − 32 − 24,7 0,200 1,0 0,150 1,5
FCAG35AVEB x4 RZASG140M7V1B 27,2 − 32 − 24,0 0,200 1,0 0.044 x4 0.3 x4
− −
& PLATFORMS

FCAG50AVEB x3 RZASG140M7V1B 26,9 32 24,0 0,200 1,0 0.039 x3 0.3 x3


FCAG71AVEB x2 RZASG140M7V1B 26,8 − 32 − 24,0 0,200 1,0 0.054 x2 0.4 x2
TOOLS

FCAG140AVEB RZASG140M7V1B 27,0 − 32 − 24,0 0,200 1,0 0,168 1,0


FFA35A2VEB x4 RZASG140M7V1B 27,7 − 32 − 24,0 0,200 1,0 0.050 x4 0.4 x4
FFA50A2VEB x3 RZASG140M7V1B 27,2 − 32 − 24,0 0,200 1,0 0.050 x3 0.4 x3
FBA35A2VEB x4 RZASG140M7V1B 28,5 − 32 − 24,0 0,200 1,0 0.089 x4 0.6 x4
FBA50A2VEB x3 RZASG140M7V1B 27,9 − 32 − 24,0 0,200 1,0 0.089 x3 0.6 x3
FBA71A2VEB x2 RZASG140M7V1B 27,0 − 32 − 24,0 0,200 1,0 0.070 x2 0.5 x2
Minimum: 198 V

Maximum 264 V

FBA140A2VEB RZASG140M7V1B 27,6 − 32 − 24,0 0,200 1,0 0,187 1,5


FNA35A2VEB x4 RZASG140M7V1B 50Hz ~ 27,2 − 32 − 24,0 0,200 1,0 0.034 x4 0.3 x4
FNA50A2VEB x3 RZASG140M7V1B 220-240V 27,6 − 32 − 24,0 0,200 1,0 0.060 x3 0.5 x3
FUA71AVEB x2 RZASG140M7V1B 27,9 − 32 − 24,0 0,200 1,0 0.046 x2 0.9 x2
FAA71AUVEB x2 RZASG140M7V1B 26,8 − 32 − 24,0 0,200 1,0 0.048 x2 0.4 x2
TECHNICAL
DRAWINGS

FVA71AMVEB x2 RZASG140M7V1B 27,2 − 32 − 24,0 0,200 1,0 0.117 x2 0.6 x2


FVA140AMVEB RZASG140M7V1B 27,5 − 32 − 24,0 0,200 1,0 0,276 1,4
FDXM35F3V1B x4 RZASG140M7V1B 27,2 − 32 − 24,0 0,200 1,0 0.034 x4 0.3 x4
FDXM50F3V1B x3 RZASG140M7V1B 27,6 − 32 − 24,0 0,200 1,0 0.060 x3 0.5 x3
FHA35AVEB x4 RZASG140M7V1B 28,5 − 32 − 24,0 0,200 1,0 0.060 x4 0.6 x4
FHA50AVEB x3 RZASG140M7V1B 27,9 − 32 − 24,0 0,200 1,0 0.060 x3 0.6 x3
FHA71AVEB x2 RZASG140M7V1B 27,7 − 32 − 24,0 0,200 1,0 0.091 x2 0.8 x2
FHA140AVEB RZASG140M7V1B 27,9 − 32 − 24,0 0,200 1,0 0,150 1,8

3D110014A
PREVIOUS

3D110014A

213
VIEW ALL RZASG-MY1 TECHNICAL
RZASG100MY1
Detailed technical drawings
DRAWINGS ON MY.DAIKIN.EU

RZASG100MY1
Compressor OFM IFM

Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAG35AVEB x3 RZASG100M7Y1B 13,0 − 16 − 10,6 0,200 1,0 0.044 x3 0.3 x3


FCAG50AVEB x2 RZASG100M7Y1B 12,7 − 16 − 10,6 0,200 1,0 0.039 x2 0.3 x2
FCAG100AVEB RZASG100M7Y1B 14,2 − 16 − 12,0 0,200 1,0 0,117 0,7
FFA35A2VEB x3 RZASG100M7Y1B 13,3 − 16 − 10,6 0,200 1,0 0.050 x3 0.4 x3
FFA50A2VEB x2 RZASG100M7Y1B 12,9 − 16 − 10,6 0,200 1,0 0.050 x2 0.4 x2
FBA100A2VEB RZASG100M7Y1B 14,6 − 16 − 12,0 0,200 1,0 0,127 1,0

Minimum: 342 V

Maximum 456 V
FNA35A2VEB x3 RZASG100M7Y1B 13,0 − 16 − 10,6 0,200 1,0 0.034 x3 0.3 x3
FNA50A2VEB x2 RZASG100M7Y1B 3N~ 50Hz 13,1 − 16 − 10,6 0,200 1,0 0.060 x2 0.5 x2
FUA100AVEB RZASG100M7Y1B 380-415V 14,9 − 16 − 12,0 0,200 1,0 0,106 1,3
FAA100AUVEB RZASG100M7Y1B 13,9 − 16 − 12,0 0,200 1,0 0,064 0,4
FVA100AMVEB RZASG100M7Y1B 14,8 − 16 − 12,0 0,200 1,0 0,238 1,2
FDXM35F3V1B x3 RZASG100M7Y1B 13,0 − 16 − 10,6 0,200 1,0 0.034 x3 0.3 x3
FDXM50F3V1B x2 RZASG100M7Y1B 13,1 − 16 − 10,6 0,200 1,0 0.060 x2 0.5 x2
FHA35AVEB x3 RZASG100M7Y1B 13,9 − 16 − 10,6 0,200 1,0 0.060 x3 0.6 x3
FHA50AVEB x2 RZASG100M7Y1B 13,3 − 16 − 10,6 0,200 1,0 0.060 x2 0.6 x2
FHA100AVEB RZASG100M7Y1B 14,9 − 16 − 12,0 0,200 1,0 0,150 1,3

3D110014A
3D110014A

RZASG125-140MY1
RZASG125-140MY1
Compressor OFM IFM

Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAG35AVEB x4 RZASG125M7Y1B 12,2 − 16 − 9,5 0,200 1,0 0.044 x4 0.3 x4


FCAG50AVEB x3 RZASG125M7Y1B 13,0 − 16 − 10,6 0,200 1,0 0.039 x3 0.3 x3
FCAG60AVEB x2 RZASG125M7Y1B 12,7 − 16 − 10,6 0,200 1,0 0.044 x2 0.3 x2
FCAG125AVEB RZASG125M7Y1B 14,6 − 16 − 12,0 0,200 1,0 0,168 1,0
FFA35A2VEB x4 RZASG125M7Y1B 12,6 − 16 − 9,5 0,200 1,0 0.050 x4 0.4 x4
FFA50A2VEB x3 RZASG125M7Y1B 13,3 − 16 − 10,6 0,200 1,0 0.050 x3 0.4 x3
FFA60A2VEB x2 RZASG125M7Y1B 13,3 − 16 − 10,6 0,200 1,0 0.050 x2 0.6 x2
FBA35A2VEB x4 RZASG125M7Y1B 13,4 − 16 − 9,5 0,200 1,0 0.089 x4 0.6 x4
FBA50A2VEB x3 RZASG125M7Y1B 13,9 − 16 − 10,6 0,200 1,0 0.089 x3 0.6 x3
FBA60A2VEB x2 RZASG125M7Y1B 13,1 − 16 − 10,6 0,200 1,0 0.070 x2 0.5 x2
Minimum: 342 V

Maximum 456 V

FBA125A2VEB RZASG125M7Y1B 15,1 − 16 − 12,0 0,200 1,0 0,187 1,5


FNA35A2VEB x4 RZASG125M7Y1B 3N~ 50Hz 12,2 − 16 − 9,5 0,200 1,0 0.034 x4 0.3 x4
FNA50A2VEB x3 RZASG125M7Y1B 380-415V 13,6 − 16 − 10,6 0,200 1,0 0.060 x3 0.5 x3
FNA60A2VEB x2 RZASG125M7Y1B 13,1 − 16 − 10,6 0,200 1,0 0.060 x2 0.5 x2
FUA125AVEB RZASG125M7Y1B 15,0 − 16 − 12,0 0,200 1,0 0,106 1,4
FDA125A5VEB RZASG125M7Y1B 15,7 − 16 − 12,0 0,200 1,0 0,350 2,1
FVA125AMVEB RZASG125M7Y1B 14,8 − 16 − 12,0 0,200 1,0 0,238 1,2
FDXM35F3V1B x4 RZASG125M7Y1B 12,2 − 16 − 9,5 0,200 1,0 0.034 x4 0.3 x4
FDXM50F3V1B x3 RZASG125M7Y1B 13,6 − 16 − 10,6 0,200 1,0 0.060 x3 0.5 x3
FDXM60F3V1B x2 RZASG125M7Y1B 13,1 − 16 − 10,6 0,200 1,0 0.060 x2 0.5 x2
FHA35AVEB x4 RZASG125M7Y1B 13,4 − 16 − 9,5 0,200 1,0 0.060 x4 0.6 x4
FHA50AVEB x3 RZASG125M7Y1B 13,9 − 16 − 10,6 0,200 1,0 0.060 x3 0.6 x3
FHA60AVEB x2 RZASG125M7Y1B 13,3 − 16 − 10,6 0,200 1,0 0.091 x2 0.6 x2
FHA125AVEB RZASG125M7Y1B 15,1 − 16 − 12,0 0,200 1,0 0,150 1,5
FCAG35AVEB x4 RZASG140M7Y1B 12,2 − 16 − 9,5 0,200 1,0 0.044 x4 0.3 x4
FCAG50AVEB x3 RZASG140M7Y1B 12,9 − 16 − 10,5 0,200 1,0 0.039 x3 0.3 x3
FCAG71AVEB x2 RZASG140M7Y1B 14,4 − 16 − 12,0 0,200 1,0 0.054 x2 0.4 x2
FCAG140AVEB RZASG140M7Y1B 14,6 − 16 − 12,0 0,200 1,0 0,168 1,0
FFA35A2VEB x4 RZASG140M7Y1B 12,6 − 16 − 9,5 0,200 1,0 0.050 x4 0.4 x4
FFA50A2VEB x3 RZASG140M7Y1B 13,2 − 16 − 10,5 0,200 1,0 0.050 x3 0.4 x3
FBA35A2VEB x4 RZASG140M7Y1B 13,4 − 16 − 9,5 0,200 1,0 0.089 x4 0.6 x4
FBA50A2VEB x3 RZASG140M7Y1B 13,8 − 16 − 10,5 0,200 1,0 0.089 x3 0.6 x3
FBA71A2VEB x2 RZASG140M7Y1B 14,6 − 16 − 12,0 0,200 1,0 0.070 x2 0.5 x2
Minimum: 342 V

Maximum 456 V

FBA140A2VEB RZASG140M7Y1B 15,1 − 16 − 12,0 0,200 1,0 0,187 1,5


FNA35A2VEB x4 RZASG140M7Y1B 3N~ 50Hz 12,2 − 16 − 9,5 0,200 1,0 0.034 x4 0.3 x4
FNA50A2VEB x3 RZASG140M7Y1B 380-415V 13,5 − 16 − 10,5 0,200 1,0 0.060 x3 0.5 x3
FUA71AVEB x2 RZASG140M7Y1B 15,4 − 16 − 12,0 0,200 1,0 0.046 x2 0.9 x2
FAA71AUVEB x2 RZASG140M7Y1B 14,4 − 16 − 12,0 0,200 1,0 0.048 x2 0.4 x2
FVA71AMVEB x2 RZASG140M7Y1B 14,8 − 16 − 12,0 0,200 1,0 0.117 x2 0.6 x2
FVA140AMVEB RZASG140M7Y1B 15,0 − 16 − 12,0 0,200 1,0 0,276 1,4
FDXM35F3V1B x4 RZASG140M7Y1B 12,2 − 16 − 9,5 0,200 1,0 0.034 x4 0.3 x4
FDXM50F3V1B x3 RZASG140M7Y1B 13,5 − 16 − 10,5 0,200 1,0 0.060 x3 0.5 x3
FHA35AVEB x4 RZASG140M7Y1B 13,4 − 16 − 9,5 0,200 1,0 0.060 x4 0.6 x4
FHA50AVEB x3 RZASG140M7Y1B 13,8 − 16 − 10,5 0,200 1,0 0.060 x3 0.6 x3
FHA71AVEB x2 RZASG140M7Y1B 15,2 − 16 − 12,0 0,200 1,0 0.091 x2 0.8 x2
FHA140AVEB RZASG140M7Y1B 15,4 − 16 − 12,0 0,200 1,0 0,150 1,8

3D110014A
3D110014A

214
RZAG-MY1
VIEW ALL RZASG-MV1 TECHNICAL

SKY AIR INTRO


RZASG-MV1
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZASG-MY1
RZASG-MV1/MY1

Symbols
MCA: Minimum Circuit Ampere [A]
TOCA: Total overcurrent amps [A]
MFA: Maximum Fuse Ampere [A]

INDOOR
MSC: Maximum current of the starting compressor [A]

UNITS
RLA: Rated load amps [A]
OFM: Outdoor fan motor
IFM: Indoor fan motor
FLA: Full Load Ampere [A]
KW: Fan motor rated output [kW]

Notes

OUTDOOR
1. The RLA is based on the following conditions.

UNITS
Cooling
Indoor temperature 27.0°C DB / 19.0°C WB
Outdoor temperature 35.0°C DB
Heating
Indoor temperature 20.0°C DB
Outdoor temperature 7.0°C DB / 6.0°C WB
2. TOCA is the total value of each overcurrent set.
3. Voltage range

AIR CURTAINS
The units are suitable for use with electrical systems in which the voltage supplied to the unit terminals is not below or above the listed range limits.

BIDDLE
4. The maximum allowable voltage that is unbalanced between phases is 2%.
5. MCA is the maximum input current.
The capacity of the MFA must be greater than that of the MCA.
Select the MFA according to the table.
6. Select the wire size according to the MCA.
7. MFA is used to select the circuit breaker and the ground fault circuit interruptor.
Earth leakage circuit breaker

VENTILATION
3D110014A

AZAS71MV1
RZASG71MV1
RZASG71MV1 3D110014A
140 620 140
30
(345∼355)

4 holes for anchor bolts

CONTROL
SYSTEMS
320
350

37

M12
52
30

37

91

30 900 3

& ACCESSORIES
2

OPTIONS
7
1

7 6

6
5
770

5
55
241
238

223
60

84 55

53 95
53 95

53 95

& PLATFORMS

89 19 19 80
28

88

TOOLS

52
142 145
13
67
71
8 16
16
58
70 102 117

1 Gas pipe connection Ø15.9 flare


5
2 Liquid pipe connection Ø9.5 flare
TECHNICAL
DRAWINGS

3 Service port (in the unit)


45 376 191
4 Electronic connection and grounding terminal M5 (in the switch box)

5 Refrigerant piping intake


6
Power supply wiring intake (knockout hole Ø34)
7
Control wiring intake (knockout hole Ø27)
8 Drain outlet
PREVIOUS

3D110013

215
3D110013
RZAG71MV1 VIEW ALL RZASG-MY1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
RZAG71MY1
Detailed technical drawings

RZASG100-140MV1
RZASG100-140MV1/MY1

RZASG-MY1
4 holes for anchor bolts
160 620 160
M12

30
Model
(340~350)

AA AB

320
345

RZAG71* / RZASG100-125* / AZAS100-125* 331 337

52
37
RZASG140* / AZAS140* 414 420

30
37

91

4
32 940
3

1
7
7
6
6
5
990

55
60

55
AA
AB

223
95

95

95
88

89 19 19 80 84
53

52
53

53
28

142 145 13
67

8 5 71 1 Gas pipe connection Ø15.9 flare


16

2 Liquid pipe connection Ø9.5 flare


16

58

3 Service port (in the unit)

4 Electronic connection and grounding terminal M5 (in the switch box)


99

5 Refrigerant piping intake


6
19

36

39
32
6 Power supply wiring intake (knockout hole Ø34)
191 154 179
7 Control wiring intake (knockout hole Ø27)

8 Drain outlet

3D110011

3D110011

216
RZAG-MV1
RZAG-MY1
VIEW ALL RZASG-MV1 TECHNICAL
RZASG-MV1

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
RZASG-MY1 Detailed technical drawings
AZAS-MV1
RZASG-MV1/MY1
AZAS-MY1

INDOOR
UNITS
OUTDOOR
UNITS
AIR CURTAINS
BIDDLE
VENTILATION
CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

217
RZAG-MV1
VIEW ALL RZASG-MY1 TECHNICAL
RZAG-MY1 DRAWINGS ON MY.DAIKIN.EU
RZASG-MV1
Detailed technical drawings
RZASG-MY1
RZASG-MV1/MY1
AZAS-MV1
AZAS-MY1

218
VIEW ALL RZASG-MV1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZASG-MV1/MY1
RZASG-MV1/MY1
To determine if adding additional refrigerant is necessary Examples

If Then Layout Additional refrigerant amount (R)

INDOOR
UNITS
(L1+L2+L3+L4+L5+L6+L7)≤ You do not have to add L2=7 m Case: Twin, standard liquid pipe size
30 m (chargeless length) additional refrigerant. (Ø6.4 mm)
1 G1 Total Ø9.5 => G1=35 m
L3=5 m
(L1+L2+L3+L4+L5+L6+L7)> You must add additional (Ø6.4 mm) G2 Total Ø6.4 => G2=7+5=12 m
30 m (chargeless length) refrigerant.
2 Case: G1>30 m
For future servicing, encircle the L1=35 m (Ø9.5 mm)
R1 Length=G1−30 m=5 m
selected amount in the tables RZASG100
below. => R1=0.35 kg

OUTDOOR
R2 Length=G2=12 m

UNITS
INFORMATION
=> R2=0.4 kg
Piping length is the largest one way length of liquid piping.
3 R R=R1+R2=0.35+0.4=0.75 kg
To determine the additional refrigerant amount (R in kg) (in L2=15 m Case: Triple, standard liquid pipe size
case of pair) (Ø6.4 mm)
1 G1 Total Ø9.5 => G1=5 m
L1 (m) L3=12 m
(Ø6.4 mm) G2 Total Ø6.4 => G2=15+12+17=44 m

AIR CURTAINS
L4=17 m 2 Case: G1≤30 m (and G1+G2>30 m)
L1: 30~40 m 40~50 m

BIDDLE
(Ø6.4 mm)
R1 R1=0.0 kg
R: 0.35 kg 0.7 kg L1=5 m (Ø9.5 mm)
R2 Length=G1+G2−30 m =
To determine the additional refrigerant amount (R in kg) (in RZASG125 5+44−30=19 m
case of twin, triple and double twin)
=> R2=0.4 kg
1 Determine R1 and R2.
3 R R=R1+R2=0.0+0.4=0.4 kg
If Then

VENTILATION
G1>30 m Use the table below to determine
R1
G1≤30 m R1=0.0 kg.
(and G1+G2>30 m) Use the table below to determine
R2.

Length (total length of liquid piping−30 m)


0~10 m 10~20 m 20~30 m 30~40 m 40~45 m

CONTROL
SYSTEMS
R1: 0.35 kg 0.7 kg 1.05 kg (a) 1.4 kg (a)
R2: 0.2 kg 0.4 kg 0.6 kg 0.8 kg (a) 1 kg (b)
(a) Only for RZASG100~140.
(b) Only for RZASG100+125.
2 Determine the additional refrigerant amount: R=R1+R2.

& ACCESSORIES
OPTIONS
4P485928-1 – 2017.04

& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

219
AZAS71-140MV1
VIEW ALL AZAS-MV1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

AZAS71-140MV1
Compressor OFM IFM

Voltage
Indoor Outdoor Power supply MCA TOCA MFA MSC RLA kW FLA kW FLA
range

FCAG71AVEB AZAS71M2V1B 17,4 − 20 − 15,4 0,094 0,9 0,054 0,4


FBA71A2VEB AZAS71M2V1B 17,5 − 20 − 15,4 0,094 0,9 0,070 0,5
FAA71AUVEB AZAS71M2V1B 17,4 − 20 − 15,4 0,094 0,9 0,048 0,4
− −

Minimum: 198 V

Maximum 264 V
FCAG100AVEB AZAS100M7V1B 21,5 25 19,0 0,200 1,0 0,117 0,7
FBA100A2VEB AZAS100M7V1B 21,8 − 25 − 19,0 0,200 1,0 0,127 1,0
50Hz ~
FAA100AUVEB AZAS100M7V1B 21,2 − 25 − 19,0 0,200 1,0 0,064 0,4
220-240V
FCAG125AVEB AZAS125M7V1B 27,8 − 32 − 24,7 0,200 1,0 0,168 1,0
FBA125A2VEB AZAS125M7V1B 28,3 − 32 − 24,7 0,200 1,0 0,187 1,5

FCAG140AVEB AZAS140M7V1B 27,0 − 32 − 24,0 0,200 1,0 0,168 1,0


FBA140A2VEB AZAS140M7V1B 27,6 − 32 − 24,0 0,200 1,0 0,187 1,5
FCAG100AVEB AZAS100M7Y1B 14,2 − 16 − 12,0 0,200 1,0 0,117 0,7
FBA100A2VEB AZAS100M7Y1B 14,6 − 16 − 12,0 0,200 1,0 0,127 1,0

Minimum: 342 V

Maximum 456 V
FAA100AUVEB AZAS100M7Y1B 13,9 − 16 − 12,0 0,200 1,0 0,064 0,4
FCAG125AVEB AZAS125M7Y1B 3N~ 50Hz 14,6 − 16 − 12,0 0,200 1,0 0,168 1,0
− −
AZAS-MV1
FBA125A2VEB AZAS125M7Y1B 380-415V 15,1 16 12,0 0,200 1,0 0,187 1,5

FCAG140AVEB AZAS140M7Y1B 14,6 − 16 − 12,0 0,200 1,0 0,168 1,0


AZAS-MY1
FBA140A2VEB AZAS140M7Y1B 15,1 − 16 − 12,0 0,200 1,0 0,187 1,5

RZAG-MV1
RZAG-MY1 3D110014A

RZASG-MV1 3D110014A
RZASG-MY1
AZAS-MV1/MY1

Symbols
MCA: Minimum Circuit Ampere [A]
TOCA: Total overcurrent amps [A]
MFA: Maximum Fuse Ampere [A]
MSC: Maximum current of the starting compressor [A]
RLA: Rated load amps [A]
OFM: Outdoor fan motor
IFM: Indoor fan motor
FLA: Full Load Ampere [A]
KW: Fan motor rated output [kW]

Notes
1. The RLA is based on the following conditions.
Cooling
Indoor temperature 27.0°C DB / 19.0°C WB
Outdoor temperature 35.0°C DB
Heating
Indoor temperature 20.0°C DB
Outdoor temperature 7.0°C DB / 6.0°C WB
2. TOCA is the total value of each overcurrent set.
3. Voltage range
The units are suitable for use with electrical systems in which the voltage supplied to the unit terminals is not below or above the listed range limits.
4. The maximum allowable voltage that is unbalanced between phases is 2%.
5. MCA is the maximum input current.
The capacity of the MFA must be greater than that of the MCA.
Select the MFA according to the table.
6. Select the wire size according to the MCA.
7. MFA is used to select the circuit breaker and the ground fault circuit interruptor.
Earth leakage circuit breaker

3D110014A

3D110014A

220
VIEW ALL AZAS-MY1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
AZAS71MV1 Detailed technical drawings

RZASG71MV1
AZAS71MV1

140 620 140

30
(345∼355)
4 holes for anchor bolts

320
350

37

INDOOR
M12

UNITS
52
30
37

91

30 900 3

2
7
1

OUTDOOR
UNITS
7 6

6
5
770

55
241
238

223
60

84 55

53 95
53 95

53 95
89 19 19 80
28

88

AIR CURTAINS
52
142 145
13

BIDDLE
67
71
8 16
16
58
70 102 117

1 Gas pipe connection Ø15.9 flare


5
2 Liquid pipe connection Ø9.5 flare

VENTILATION
3 Service port (in the unit)
45 376 191
4 Electronic connection and grounding terminal M5 (in the switch box)

5 Refrigerant piping intake


6
Power supply wiring intake (knockout hole Ø34)
7
Control wiring intake (knockout hole Ø27)
8 Drain outlet

3D110013

CONTROL
SYSTEMS
3D110013

& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

221
RZAG71MV1 VIEW ALL AZAS-MV1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
RZAG71MY1
Detailed technical drawings

RZASG100-140MV1
AZAS100-140MV1/MY1

RZASG-MY1
4 holes for anchor bolts
160 620 160
M12

30
Model
(340~350)

AA AB

320
345

RZAG71* / RZASG100-125* / AZAS100-125* 331 337

52
37
RZASG140* / AZAS140* 414 420

30
37

91

4
32 940
3

1
7
7
6
6
5
990

55
60

55
AA
AB

223
95

95

95
88

89 19 19 80 84
53

52
53

53
28

142 145 13
67

8 5 71 1 Gas pipe connection Ø15.9 flare


16

2 Liquid pipe connection Ø9.5 flare


16

58

3 Service port (in the unit)

4 Electronic connection and grounding terminal M5 (in the switch box)


99

5 Refrigerant piping intake


6
19

36

39
32
6 Power supply wiring intake (knockout hole Ø34)
191 154 179
7 Control wiring intake (knockout hole Ø27)

8 Drain outlet

3D110011

3D110011

222
RZAG-MV1
RZAG-MY1
VIEW ALL AZAS-MY1 TECHNICAL
RZASG-MV1

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
RZASG-MY1 Detailed technical drawings
AZAS-MV1
AZAS-MV1/MY1
AZAS-MY1

INDOOR
UNITS
OUTDOOR
UNITS
AIR CURTAINS
BIDDLE
VENTILATION
CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

223
RZAG-MV1
VIEW ALL AZAS-MV1 TECHNICAL
RZAG-MY1 DRAWINGS ON MY.DAIKIN.EU
RZASG-MV1
Detailed technical drawings
RZASG-MY1
AZAS-MV1/MY1
AZAS-MV1
AZAS-MY1

224
VIEW ALL AZAS-MY1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
AZAS-MV1/MY1
AZAS-MV1/MY1

To determine the complete recharge amount (kg)

Model Length
5~30 m

INDOOR
UNITS
AZAS71 2.45 kg
AZAS100-125 2.6 kg
AZAS140 2.9 kg

4P485929-1 – 2017.04

OUTDOOR
UNITS
AIR CURTAINS
BIDDLE
VENTILATION
CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

225
VIEW ALL RZQG-L9V1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZQG-L9V1
RZQG-L9V1
Unit combination restrictions Power supply COMP OFM IFM
Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA kW FLA

2xFNA35A RZQG71L9V1B 17,2 20 - 15,6 0,094 0,4 2x0.034 2x0.3

2xFNA50A RZQG100L9V1B 28,9 32 - 24,2 0.094 + 0.4 + 0.4 2x0.06 2x0.5


0.094

0.094 +
3xFNA35A RZQG100L9V1B 28,8 32 - 24,2 0.094 0.4 + 0.4 3x0.034 3x0.3
MAX. 50Hz
220- 264V 0.094 +
2xFNA60A RZQG125L9V1B 50 29 32 - 24,2 0.4 + 0.4 2x0.06 2x0.5
240V MIN. 50Hz 0.094
198V
0.094 +
3xFNA50A RZQG125L9V1B 29,5 32 - 24,2 0.4 + 0.4 3x0.06 3x0.5
0.094

0.094 +
4xFNA35A RZQG125L9V1B 29,2 32 - 24,2 0.094 0.4 + 0.4 4x0.034 4x0.3

0.094 + 0.4 + 0.4 3x0.06 3x0.5


3xFNA50A RZQG140L9V1B 29,5 32 - 24,2
0.094

Notes
1 The RLA is based on the following conditions.
Indoor temperature 27°CDB / 19°C WB.
Outdoor temperature 35°CDB.
2 Select the wire size according to the MCA.
3 The maximum allowable voltage that is unbalanced between phases is 2%.
4 Use a circuit breaker instead of a fuse.

Symbols
① Hz OFM Outdoor fan motor
② Voltage IFM Indoor fan motor
③ Voltage range FLA Full Load Ampere (A)
MCA Minimum Circuit Ampere (A) kW Fan motor rated output [kW]
MFA Maximum Fuse Ampere (A) RHz Rated operating frequency [Hz]
RLA Rated load amps [A] COMP Compressor
3D096315C

RZQG71-125L9V1
RZQG71-125L9Vl

Unit combination restrictions Power supply COMP OFM IFM


Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA kW FLA

FBA71A RZQG71L9V1B 16,4 20 51 15,6 0,094 0,4 0,07 0,5

2xFBA35A RZQG71L9V1B 17,1 20 - 15,6 0,094 0,4 2x0.089 2x0.6

0.094 +
FBA100A RZQG100L9V1B 28,9 32 49 24,2 0.4 + 0.4 0,127 1,0
0.094

MAX. 50Hz 0.094 +


2xFBA50A RZQG100L9V1B 29,1 32 - 24,2 0.4 + 0.4 2x0.089 2x0.6
220- 264V 0.094
50
240V MIN. 50Hz
198V
- 0.094 +
3xFBA35A RZQG100L9V1B 29,7 32 24,2 0.4 + 0.4 3x0.089 3x0.6
0.094

0.094 +
FBA125A RZQG125L9V1B 29,5 32 64 24,2 0.4 + 0.4 0,187 1,5
0.094

- 0.094 +
2xFBA60A RZQG125L9V1B 29 32 24,2 0.4 + 0.4 2x0.070 2x0.5
0.094

- 0.094 +
3xFBA50A RZQG125L9V1B 29,8 32 24,2 0.4 + 0.4 3x0.089 3x0.6
0.094

Notes
1 The RLA is based on the following conditions.
Indoor temperature 27°C DB/ 19°C WB
Outdoor temperature 35°C DB
2 Select the wire size according to the MCA.
3 The maximum allowable voltage that is unbalanced between phases is 2%.
4 Use a circuit breaker instead of a fuse.

Symbols
1 Hz OFM Outdoor fan motor
2 Voltage IFM Indoor fan motor
3 Voltage range FLA Full Load Ampere (A)
kW Fan motor rated output (kW)
MCA Minimum Circuit Ampere (A)
RHz Rated operating frequency [Hz]
MFA Maximum Fuse Ampere (A)
COMP Compressor
RLA Rated load amps (A)

30094863B

226
VIEW ALL
Unit combination RZQG-L9V1 TECHNICAL
restrictions Power supply COMP OFM IFM

SKY AIR INTRO


Indoor DRAWINGS ONOutdoor
MY.DAIKIN.EU 1 2 3 MCA MFA RHz RLA kW FLA kW FLA
-
Detailed technical drawings
0.094 +
4xFBA35A RZQG125L9V1B 30,4 32 24,2 0.4 + 0.4 4x0.089 4x0.6
0.094

RZQG125-140L9V1
RZQG125-140L9Vl
0.094 +
FBA140A RZQG140L9V1B 29,5 32 68 24,2 0.4 + 0.4 0,187 1,5
0.094
Unit combination restrictions Power supply MAX. 50Hz COMP OFM IFM
220- 264V - 0.094 +
2xFBA71A
Indoor Outdoor RZQG140L9V1B 50
1 2
240V
3
MIN. 50Hz
29
MCA 32
MFA RHz 24,2
RLA kW 0.4FLA
0.094
+ 0.4 2x0.07
kW 2x0.5
FLA
198V
- 0.094 +
4xFBA35A RZQG125L9V1B 30,4 32 24,2 0.094 0.4 + 0.4 4x0.089 4x0.6
3xFBA50A RZQG140L9V1B 29,8 32 - 24,2 0.094 + 0.4 + 0.4 3x0.089 3x0.6
0.094

INDOOR
UNITS
0.094 +
FBA140A RZQG140L9V1B 29,5 32 68 24,2 0.094 0.4 + 0.4 0,187 1,5
4xFBA35A RZQG140L9V1B 30,4 32 - 24,2 0.094 + 0.4 + 0.4 4x0.089 4x0.6
0.094
MAX. 50Hz
220- 264V - 0.094 +
2xFBA71A RZQG140L9V1B 50 29 32 24,2 0.4 + 0.4 2x0.07 2x0.5
240V MIN. 50Hz 0.094
198V
- 0.094 +
3xFBA50A RZQG140L9V1B 29,8 32 24,2 0.4 + 0.4 3x0.089 3x0.6
0.094

- 0.094 +
4xFBA35A RZQG140L9V1B 30,4 32 24,2 0.4 + 0.4 4x0.089 4x0.6

OUTDOOR
0.094

UNITS
Notes
1 The RLA is based on the following conditions.
Indoor temperature 27°C DB/ 19°C WB
Outdoor temperature 35°C DB
2 Select the wire size according to the MCA.
3 The maximum allowable voltage that is unbalanced between phases is 2%.
4 Use a circuit breaker instead of a fuse.

AIR CURTAINS
Symbols
Notes

BIDDLE
1 Hz
2 1 The RLA is based on the following conditions.
Voltage
3 Indoor
Voltagetemperature
range 27°C DB/ 19°C WB
MCA Minimumtemperature
Outdoor 35°C[A]
Circuit Ampere DB
MFA2 Select the wire
Maximum Fusesize according
Ampere [A] to the MCA.
RLA3 The maximum
Rated allowable
load amps [A] voltage that is unbalanced between phases is 2%.
4 Use a circuit breaker instead of a fuse.

Symbols 300948638
RZQG125-140L9V1
1 Hz
2 Voltage

VENTILATION
3 Voltage range
RZQG125-140L9V1
MCA Minimum Circuit Ampere [A]
MFA Maximum Fuse Ampere [A]
RLA Rated load amps [A]
Infrastructure Cooling
Compressor OFM IFM

Indoor Outdoor Power supply Voltage range MCA TOCA MFA MSC RLA kW FLA kW FLA
300948638

FCAHG71G x2 RZQG125L9V1B 28,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,091 x2 0,5 x2


FCAHG140G RZQG125L9V1B 29,3 - 32 - 24,2 0.094+0.094 0.4+0.4 0,244 1,4
FCAG35A x4 RZQG125L9V1B 29,0 - 32 - 24,2 0.094+0.094 0.4+0.4 0,044 x4 0,3 x4
FCAG50A x3 RZQG125L9V1B 28,6 - 32 - 24,2 0.094+0.094 0.4+0.4 0,039 x3 0,3 x3
FCAG71A x2 RZQG125L9V1B 28,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,054 x2 0,4 x2
FCAG140A RZQG125L9V1B 28,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,168 1,0
FFA35A x4 RZQG125L9V1B 29,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,050 x4 0,4 x4

CONTROL
SYSTEMS
FFA50A x3 RZQG125L9V1B 29,0 - 32 - 24,2 0.094+0.094 0.4+0.4 0,050 x3 0,4 x3
Maximum 264V
Minimum 198V

FBA35A x4 RZQG125L9V1B 30,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,089 x4 0,6 x4


FBA50A x3 RZQG125L9V1B 29,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,089 x3 0,6 x3
1~50Hz - -
FBA71A x2 RZQG125L9V1B 28,8 32 24,2 0.094+0.094 0.4+0.4 0,070 x2 0,5 x2
220-240V - -
FBA140A RZQG125L9V1B 29,4 32 24,2 0.094+0.094 0.4+0.4 0,187 1,5
FHA35A x4 RZQG125L9V1B 30,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,060 x4 0,6 x4
FHA50A x3 RZQG125L9V1B 29,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,060 x3 0,6 x3
FHA71A x2 RZQG125L9V1B 29,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,091 x2 0,8 x2
FHA140A RZQG125L9V1B 29,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,150 1,8
FUA71A x2 RZQG125L9V1B 29,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,046 x2 0,9 x2
FAA71A x2 RZQG125L9V1B 28,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,048 x2 0,4 x2
FVA140A RZQG125L9V1B 29,3 - 32 - 24,2 0.094+0.094 0.4+0.4 0,276 1,4
FDXM35F3 x4 RZQG125L9V1B 29,0 - 32 - 24,2 0.094+0.094 0.4+0.4 0,034 x4 0,3 x4
FDXM50F3 x3 RZQG125L9V1B 29 4 - 32 - 24 2 0.094+0.094 0.4+0.4 O 060 x3 O 5 x3
- -

& ACCESSORIES
FCAHG71G x2 RZQG140L9V1B 28,8 32 24,2 0.094+0.094 0.4+0.4 0,091 x2 0,5 x2
FCAHG140G RZQG140L9V1B 29,3 - 32 - 24,2 0.094+0.094 0.4+0.4 0,244 1,4
- -

OPTIONS
FCAG35A x4 RZQG140L9V1B 29,0 32 24,2 0.094+0.094 0.4+0.4 0,044 x4 0,3 x4
FCAG50A x3 RZQG140L9V1B 28,6 - 32 - 24,2 0.094+0.094 0.4+0.4 0,039 x3 0,3 x3
FCAG71A x2 RZQG140L9V1B 28,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,054 x2 0,4 x2
FCAG140A RZQG140L9V1B 28,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,168 1,0
FFA35A x4 RZQG140L9V1B 29,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,050 x4 0,4 x4
Maximum 264V

- -
Minimum 198V

FFA50A x3 RZQG140L9V1B 29,0 32 24,2 0.094+0.094 0.4+0.4 0,050 x3 0,4 x3


FBA35A x4 RZQG140L9V1B 30,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,089 x4 0,6 x4
FBA50A x3 RZQG140L9V1B 29,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,089 x3 0,6 x3
1~50Hz - -
FBA71A x2 RZQG140L9V1B 28,8 32 24,2 0.094+0.094 0.4+0.4 0,070 x2 0,5 x2
220-240V - -
FBA140A RZQG140L9V1B 29,4 32 24,2 0.094+0.094 0.4+0.4 0,187 1,5
FHA35A x4 RZQG140L9V1B 30,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,060 x4 0,6 x4
FHA50A x3 RZQG140L9V1B 29,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,060 x3 0,6 x3
FHA71A x2 RZQG140L9V1B 29,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,091 x2 0,8 x2
FHA140A RZQG140L9V1B 29,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,150 1,8
FUA71A x2 RZQG140L9V1B 29,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,046 x2 0,9 x2
FAA71A x2 RZQG140L9V1B 28,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,048 x2 0,4 x2
& PLATFORMS

FVA140A RZQG140L9V1B 29,3 - 32 - 24,2 0.094+0.094 0.4+0.4 0,276 1,4


FDXM35F3 x4 RZQG140L9V1B 29,0 - 32 - 24,2 0.094+0.094 0.4+0.4 0,034 x4 0,3 x4
FDXM50F3 x3 RZQG140L9V1B 29 4 - 32 - 24 2 0.094+0.094 0.4+0.4 0,060x3 0,5 x3
TOOLS

Symbols

MCA: Minimum Circuit Ampere [A]


TOCA: Total overcurrent amps [A]
MFA: Maximum Fuse Ampere [A]
MSC: Maximum current of the starting compressor [A]
RLA: Rated load amps [A] OFM: Outdoor fan motor
IFM: Indoor fan motor
FLA: Full Load Ampere [A]
KW: Fan motor rated output [kW]

Notes
TECHNICAL
DRAWINGS

1. The RLA is based on the following conditions.


Cooling Indoor temperature 27.0°C DB / 19.0°WB
Outdoor temperature 35.0°C DB

Heating Indoor temperature 20.0°C DB


Outdoor temperature 7.0°C DB / 6.D°C WB
2. TOCA is the total value of each overcurrent set.
3. Voltage range
The units are suitable for use with electrical systems in which the voltage supplied to the unit terminals is not below or above the listed range limits.
4. The maximum allowable voltage that is unbalanced between phases is 2%.
5. MCA is the maximum input current.
The capacity of the MFA must be greater than that of the MCA.
PREVIOUS

Select the MFA according to the table.


6. Select the wire size according to the MCA. 3D098291
7. MFA is used to select the circuit breaker and the ground fault circuit interrupter.
Earth leakage circuit breaker
227
VIEW ALL RZQG-L9V1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQG125-140L9V1
Comp OFM IFM
Indoor Outdoor Hz- Voltage MCA TOCA MFA MSC RLA kW FLA kW FLA
FCAHG125G 29.3 - 32 - 24.2 0.094+0.094 0.4+0.4 0.244 1.4
FCAG35A x4 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0.044x4 0.3x4
FCAG50A x3 28.6 - 32 - 24.2 0.094+0.094 0.4+0.4 0.039x3 0.3x3
FCAG60A x2 28.3 - 32 - 24.2 0.094+0.094 0.4+0.4 0.044x2 0.3x2
FCAG125A 28.8 - 32 - 24.2 0.094+0.094 0.4+0.4 0.168 1.0
FFA35A x4 29.5 - 32 - 24.2 0.094+0.094 0.4+0.4 0.050x4 0.4x4
FFA50A x3 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0.050x3 0.4x3
FFA60A x2 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0.050x2 0.6x2
FDXM35F3 x4 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0.034x4 0.3x4
FDXM50F3 x3 29.4 - 32 - 24.2 0.094+0.094 0.4+0.4 0.06x3 0.5x3
FDXM60F3 x2 28.8 - 32 - 24.2 0.094+0.094 0.4+0.4 0.060x2 0.5x2
FBA35A x4 33.5 - 40 - 24.2 0.094+0.094 0.4+0.4 0.140x4 1.2x4
FBA50A x3 32.0 - 40 - 24.2 0.094+0.094 0.4+0.4 0.140x3 1.2x3
FBA60A x2 RZQG125L9V1 SOHz Min.198V 30.3 - 32 - 24.2 0.094+0.094 0.4+0.4 0.350x2
220-240V Max.264V 1.1x2
FBA125A 30.1 - 32 - 24.2 0.094+0.094 0.4+0.4 0.350 2.1
FHA35A x4 30.5 - 32 - 24.2 0.094+0.094 0.4+0.4 0.062x4 0.6x4
FHA50A x3 29.8 - 32 - 24.2 0.094+0.094 0.4+0.4 0.062x3 0.6x3
FHA60A x2 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0.062x2 0.6x2

FUA125A 28.8 - 32 - 24.2 0.094+0.094 0.4+0.4 0.289 1.0


FDA125A 30.1 - 32 - 24.2 0.094+0.094 0.4+0.4 0.350 2.1
FVA125A 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0.238 1.2
FHA35A x4 30.5 - 32 - 24.2 0.094+0.094 0.4+0.4 0,060 x 4 0,6 X 4
FHA50A x3 29.8 - 32 - 24.2 0.094+0.094 0.4+0.4 0,060 x 3 0,6 X 3
FHA60A x2 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0,091 x 2 0,6 X 2
FHA125A 29.4 - 32 - 24.2 0.094+0.094 0.4+0.4 0.150 1.5
FUA125A 29.3 - 32 - 24.2 0.094+0.094 0.4+0.4 0.106 1.4
FCAHG71G x2 28.8 - 32 - 24.2 0.094+0.094 0.4+0.4 0.091x2 0.5x2
FCAHG140G 29.3 - 32 - 24.2 0.094+0.094 0.4+0.4 0.244 1.4
FCAG35A x4 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0.044x4 0.3x4
FCAG50A x3 28.6 - 32 - 24.2 0.094+0.094 0.4+0.4 0.039x3 0.3x3
FCAG71A x2 28.5 - 32 - 24.2 0.094+0.094 0.4+0.4 0.054x2 0.4x2
FCAG140A 28.8 - 32 - 24.2 0.094+0.094 0.4+0.4 0.168 1.0
FFA35A x4 29.5 - 32 - 24.2 0.094+0.094 0.4+0.4 0.050x4 0.4x4
FFA50A x3 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0.050x3 0.4x3
FDXM35F3 x4 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0.034x4 0.3x4
FDXM50F3 x3 29.4 - 33 - 25.2 0.094+0.094 0.4+0.4 0.06x3 0.5x3
SOHz Min.198V - -
FBA35A x4 RZQG140L9V1 220-240V Max.264V 33.5 40 24.2 0.094+0.094 0.4+0.4 0.140x4 1.2x4
FBA50A x3 32.0 - 40 - 24.2 0.094+0.094 0.4+0.4 0.140x3 1.2x3
FBA71A x2 30.3 - 32 - 24.2 0.094+0.094 0.350x2 1.1x2
0.4+0.4
FBA140A 30.1 - 32 - 24.2 0.094+0.094 0.350
0.4+0.4 2.1
FAA71A x2 28.5 - 32 - 24.2 0.094+0.094 0.048x2 0.4x2
0.4+0.4
FVA140A 29.3 - 32 - 24.2 0.094+0.094 0.276 1.4
0.4+0.4
FHA35A x4 30.5 - 32 - 24.2 0.094+0.094 0.4+0.4 0,060 X 4 0,6 x4
FHA50A x3 29.8 - 32 - 24.2 0.094+0.094 0.4+0.4 0,060 X 3 0,6 X 3
FHA71A x2 29.5 - 32 - 24.2 0.094+0.094 0.4+0.4 0,091 X 2 0,8 X 2
FHA140A 29.8 - 32 - 24.2 0.094+0.094 0.4+0.4 0.150 1.8
FUA71A x2 29.8 - 32 - 24.2 0.094+0.094 0.4+0.4 0,046 X 2 0,9 X 2

SYMBOLS NOTES
MCA Min. Circuit Amps. (A) 1 RLA is based on the following conditions:
TOCA Total Over-Current Amps. (A) Power supply: 50Hz 230V
MFA Max. Fuse Amps. Cooling
MSC (See note 7) (A) Indoor temperature 27.0'CDB/19.0'CWB
RLA Max. current during the starting compressor. (A) Rated Load Amps. (A) Outdoor temperature 35.0'CDB
OFM Outdoor Fan Motor. (A) Heating
IFM Indoor Fan Motor. Indoor temperature 20.0'CDB
FLA Full Load Amps. Outdoor temperature 7.0'CDB / 6.0'CWB
kW Fan Motor Rated Output (kW) 2 TOCA means the total value of each OC set.
3 Voltage range
Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below orabove listed range limits.
4 Maximum allowable voltage variation between phases is 2%.
5 MCA represents maximum input current MFA represents capacity
which may accept MCA.
(next lower standard fuse rating, min.15A)
6
7
Select wire size based on the larger value of MCA or TOCA.
MFA is used to select the circuit breaker and the ground fault circuit interrupter.
3D090680
(earth leakage circuit breaker)

3D090680

RZQG140L9V1
RZQG140L9V1

Unit combination restrictions Power supply COMP OFM IFM


Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA kW FLA
220- MAX. 50Hz 264V 0.094 +
4xFNA35A RZQG140L9V1B 50 MIN. 50Hz 198V 29,2 32 - 24,2 0.4 + 0.4 4x0.034 4x0.3
240V 0.094

Notes
1 The RLA is based on the following conditions.
Indoor temperature 27°CDB / 19°C WB.
Outdoor temperature 35°CDB.
2 Select the wire size according to the MCA.
3 The maximum allowable voltage that is unbalanced between phases is 2%.
4 Use a circuit breaker instead of a fuse.

Symbols
① Hz OFM Outdoor fan motor
② Voltage IFM Indoor fan motor
③ Voltage range FLA Full Load Ampere (A)
MCA Minimum Circuit Ampere (A) kW Fan motor rated output [kW]
MFA Maximum Fuse Ampere (A) RHz Rated operating frequency [Hz]
RLA Rated load amps [A] COMP Compressor

3D096315C

228
VIEW ALL RZQG-L8Y1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZQG71-100L8Y1
RZQG71-100L8Y1
Comp OFM IFM
Phase ~
Indoor Outdoor Hz Power supply Voltage range MCA TOCA MFA MSC RLA kW FLA kW FLA
FCAG71A 11,5 - 16 - 9,6 0,094 0,4 0,048 0,4
FCAHG71G 11,6 - 16 - 9,6 0,094 0,4 0,091 0,5
FCAG35A x2 11,8 - 16 - 9,6 0,094 0,4 0.044x2 0.3x2
FCAG71A 11,5 - 16 - 9,6 0,094 0,4 0,054 0,4

INDOOR
UNITS
FFA35A x2 12,0 - 16 - 9,6 0,094 0,4 0.05x2 0.4x2
FDXM35F3 x2 11,8 - 16 - 9,6 0,094 0,4 0.034x2 0.3x2
FBA35A x2 RZQG71L8Y1B 3N ~ 50Hz Min. 342V 14,0 - 16 - 9,6 0,094 0,4 0.140x2 1.2x2
FBA71A 380-415V Max. 456V 12,4 - 16 - 9,6 0,094 0,4 0,350 1,1
FAA71A 11,5 - 16 - 9,6 0,094 0,4 0,048 0,4
FVA71A 11,8 - 16 - 9,6 0,094 0,4 0,117 0,6
FHA35A x2 12,5 - 16 - 9,6 0,094 0,4 0,060x2 0,6x2
FHA71A 12,0 - 16 - 9,6 0,094 0,4 0,091 0,8
FUA71A 12,1 - 16 - 9,6 0,094 0,4 0,046 0,9
FCAG100A 17,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,106 1,0

OUTDOOR
FCAHG100G 18,1 - 20 - 14,2 0.094+0.094 0.4+0.4 0,221 1,3

UNITS
FCAG35A x3 17,6 - 20 - 14,2 0.094+0.094 0.4+0.4 0.044x3 0.3x3
FCAG50A x2 17,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0.039x2 0.3x2
FCAG100A 17,4 - 20 - 14,2 0.094+0.094 0.4+0.4 0,117 0,7
FFA35A x3 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0.05x3 0.4x3
FFA50A x2 17,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0.05x2 0.4x2
FDXM35F3 x3 17,6 - 17,6 - 14,2 0.094+0.094 0.4+0.4 0.034x3 0.3x3
FDXM50F3 x2 17,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0.06x2 0.5x2
RZQG100L8Y1B
FBA35A x3 21,0 - 25 - 14,2 0.094+0.094 0.4+0.4 0.140x3 1.2x3
FBA50A x2 19,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0.140x2 1.2x2

AIR CURTAINS
FBA100A 18,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,350 1,6

BIDDLE
FAA100A 17,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,064 0,4
FVA100A 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,238 1,2
FHA35A x3 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,060x3 0,6x3
FHA50A x2 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,060x2 0,6x2
FHA100A 18,1 - 20 - 14,2 0.094+0.094 0.4+0.4 0,150 1,3
FUA100A 18,1 - 20 - 14,2 0.094+0.094 0.4+0.4 0,106 1,3

SYMBOLS NOTES
MCA : : Min. Circuit Amps. (A) 1. RLA is based on the following conditions:
MFA : Max. Fuse Amps(see note 6). (A) Cooling

VENTILATION
MSC : Max. current during the starting compressor. (A) Indoor temp.: 27° CDB/19.0° CWB
RLA : Rated Load Amps. (A) Outdoor temp.: 35° CDB
OFM : Outdoor Fan Motor. (A) 2. Voltage range.
Units are suitable for use on electrical systems where voltage supplied
FLA : Full Load Amps. (A) to unit terminal is not below or above listed range limits.
W : Fan Motor Rated Output (W) 3. Maximum allowable voltage variation between phases is 2%.
4. MCA represents maximum input current.
MFA represents capacity which may accept MCA.
5. Select wire size based on the value of MCA.
6. MFA is used to select the circuit breaker and the ground fault circuit interrupter.
(Earth leakage circuit breaker).

CONTROL
SYSTEMS
3D077810B
3D077810B

RZQG71-100L8Y1
RZQG71-100L8Y1

& ACCESSORIES
OPTIONS
Unit combination restrictions Power supply COMP OFM IFM
Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA kW FLA

3xFBA60A RZQ200C7Y1B 11,8 16 - 9,6 0,094 0,4 0,07 0,5

4xFBA50A RZQ200C7Y1B MAX. 50Hz 12 16 - 9,6 0,094 0,4 2x0.089 2x0.6


3N~ 415V
400V
& PLATFORMS

50Hz MIN. 50Hz


2xFBA125A RZQ250C7Y1B 380V 17,9 20 14,2 0.094 + 0.4 + 0.4 0,127 1,0
-
TOOLS

0.094

0.094 +
4xFBA60A RZQ250C7Y1B 18,1 20 - 14,2 0.4 + 0.4 2x0.089 2x0.6
0.094

Notes
1 The RLA is based on the following conditions.
Indoor temperature 27°CDB / 19°C WB.
Outdoor temperature 35°CDB.
2 Select the wire size according to the MCA.
TECHNICAL

3 The maximum allowable voltage that is unbalanced between phases is 2%.


DRAWINGS

4 Use a circuit breaker instead of a fuse.

Symbols
① Hz OFM Outdoor fan motor
② Voltage IFM Indoor fan motor
③ Voltage range FLA Full Load Ampere (A)
MCA Minimum Circuit Ampere (A) kW Fan motor rated output [kW]
MFA Maximum Fuse Ampere (A) RHz Rated operating frequency [Hz]
RLA Rated load amps [A] COMP Compressor 3D094863B
PREVIOUS

229
VIEW ALL RZQG-L8Y1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQG71-100L8Y1

RZQG71-100L8Yl

Unit combination restrictions Power supply COMP OFM IFM


Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA kW FLA

2xFNA35A RZQG71L81B MAX. 50Hz 11,9 16 - 9,6 0,094 0.4 2x0.034 2x0.3
3N~ 380- 456V
50Hz 415V MIN. 50Hz
- 0.094 +
2xFNA50A RZQG100L8Y1B 342V 17,9 20 14,2 0.4 + 0.4 2x0.06 2x0.5
0.094

Notes
1 The RLA is based on the following conditions.
Indoor temperature 27°C DB/ 19°C WB
Outdoor temperature 35°C DB
2 Select the wire size according to the MCA.
3 The maximum allowable voltage that is unbalanced between phases is 2%.
4 Use a circuit breaker instead of a fuse.

Symbols
1 Hz OFM Outdoor fan motor
2 Voltage IFM Indoor fan motor
3 Voltage range FLA Full Load Ampere (A)
kW Fan motor rated output (kW)
MCA Minimum Circuit Ampere (A)
RHz Rated operating frequency [Hz]
MFA Maximum Fuse Ampere (A)
COMP Compressor
RLA Rated load amps (A)

3D096315C

RZQG71-100L8Yl

RZQG71-100L8Y1

Infrastructure Cooling
Compressor OFM IFM

Indoor Outdoor Power supply Voltage range MCA TOCA MFA MSC RLA kW FLA kW FLA

FCAHG100G RZQG71 L8Y1 B 12,6 - 16 - 9,6 0,094 0,4 0,221 1,3


FCAG35A x3 RZQG71 L8Y1 B 12,1 - 16 - 9,6 0,094 0,4 0,044 x3 0,3 x3
FCAG50A x2 RZQG71 L8Y1 B 11,8 - 16 - 9,6 0,094 0,4 0,039 x2 0,3 x2
FCAG100A RZQG71 L8Y1 B 11,9 - 16 - 9,6 0,094 0,4 0,117 0,7
FFA35A x3 RZQG71 L8Y1 B 12,5 - 16 - 9,6 0,094 0,4 0,050 x3 0,4 x3
FFA50A x2 RZQG71 L8Y1 B 12,0 - 16 - 9,6 0,094 0,4 0,050 x2 0,4 x2
Maximum: 456V
Minimum: 342V

FBA35A x3 RZQG71 L8Y1 B 13,3 - 16 - 9,6 0,094 0,4 0,089 x3 0,6 x3


FBA50A x2 RZQG71 L8Y1 B 12,5 - 16 - 9,6 0,094 0,4 0,089 x2 0,6 x2
3N~50Hz - -
FBA100A RZQG71 L8Y1 B 12,3 16 9,6 0,094 0,4 0,127 1,0
380-415V - -
FHA35A x3 RZQG71 L8Y1 B 13,3 16 9,6 0,094 0,4 0,060 x3 0,6 x3
FHA50A x2 RZQG71 L8Y1 B 12,5 - 16 - 9,6 0,094 0,4 0,060 x2 0,6 x2
FHA100A RZQG71 L8Y1 B 12,6 - 16 - 9,6 0,094 0,4 0,150 1,3
FUA100A RZQG71 L8Y1 B 12,6 - 16 - 9,6 0,094 0,4 0,106 1,3
FAA100A RZQG71 L8Y1 B 11,5 - 16 - 9,6 0,094 0,4 0,064 0,4
FVA100A RZQG71 L8Y1 B 12,5 - 16 - 9,6 0,094 0,4 0,238 1,2
FDXM35F3 x3 RZQG71 L8Y1 B 12,1 - 16 - 9,6 0,094 0,4 0,034 x3 0,3 x3
FDXM50F3 x2 RZQG71 L8Y1 B 12,3 - 16 - 96 0,094 0,4 0,060 x2 0,5 x2
FCAHG71G x2 RZQG100L8Y1B 17,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,091 x2 0,5 x2
FCAHG140G RZQG100L8Y1B 18,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0,244 1,4
FCAG35A x4 RZQG100L8Y1B 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,044 x4 0,3 x4
FCAG50A x3 RZQG100L8Y1B 17,6 - 20 - 14,2 0.094+0.094 0.4+0.4 0,039 x3 0,3 x3
FCAG71A x2 RZQG100L8Y1B 17,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,054 x2 0,4 x2
FCAG140A RZQG100L8Y1B 17,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,168 1,0
FFA35A x4 RZQG100L8Y1B 18,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,050 x4 0,4 x4
FFA50A x3 RZQG100L8Y1B 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,050 x3 0,4 x3
Maximum: 456V
Minimum: 342V

FBA35A x4 RZQG100L8Y1B 19,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,089 x4 0,6 x4


FBA50A x3 RZQG100L8Y1B 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,089 x3 0,6 x3
3N~50Hz - -
FBA71A x2 RZQG100L8Y1B 17,8 20 14,2 0.094+0.094 0.4+0.4 0,070 x2 0,5 x2
380-415V - -
FBA140A RZQG100L8Y1B 18,4 20 14,2 0.094+0.094 0.4+0.4 0,187 1,5
FHA35A x4 RZQG100L8Y1B 19,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,060 x4 0,6 x4
FHA50A x3 RZQG100L8Y1B 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,060 x3 0,6 x3
FHA71A x2 RZQG100L8Y1B 18,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,091 x2 0,8 x2
FHA140A RZQG100L8Y1B 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,150 1,8
FUA71A x2 RZQG100L8Y1B 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,046 x2 0,9 x2
FAA71A x2 RZQG100L8Y1B 17,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,048 x2 0,4 x2
FVA140A RZQG100L8Y1B 18,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0,276 1,4
FDXM35F3 x4 RZQG100L8Y1B 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,034 x4 0,3 x4
FDXM50F3 x3 RZQG100L8Y1B 18,4 - 20 - 14,2 0.094+0.094 0.4+0.4 0,060 x3 0,5 x3

Symbols Notes
MCA: Min. Circuit Amps. (A) 1 RLA is based on the following conditions:
TOCA: Total Over-Current Amps. (A) Cooling
MFA: Max. Fuse Amps Indoor temperature 27.0°CDB/19.0°CWB
MSC: Max. current during the starting compressor. (A) Outdoor temperature 35.0°CDB
RLA: Rated Load Amps. (A) Heating
OFM: Outdoor Fan Motor. (A) Indoor temperature 20.0°CDB
IFM: Indoor Fan Motor. Outdoor temperature 7.0°CDB / 6.0°CWB
FLA: Full Load Amps. 2 TOCA means the total value of each OC set.
KW Fan Motor Rated Output (kW) 3 Voltage range
Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below or above listed range limits.
4 Maximum allowable voltage variation between phases is 2%.
5 MCA represents maximum input current. MFA represents capacity which may accept MCA.
(next lower standard fuse rating, min.15A)
6 Select wire size based on the larger value of MCA or TOCA.
7 MFA is used to select the circuit breaker and the ground fault circuit interrupter.
(earth leakage circuit breaker)
3D098292

230
VIEW ALL RZQG-L8Y1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZQG71-100L9V1
RZQG71-100L8Y1
Comp OFM IFM
Indoor Outdoor Hz- Voltage MCA TOCA MFA MSC RLA kW FLA kW FLA
FCAHG71G 18.2 - 20 - 15.6 0.094 0.4 0.091 0.5
FCAG35A x2 18.4 - 20 - 15.6 0.094 0.4 0.044x2 0.3x2
FCAG71A 18.1 - 20 - 15.6 0.094 0.4 0.054 0.4

INDOOR
FFA35A x2 18.6 - 20 - 15.6 0.094

UNITS
0.4 0.050x2 0.4x2
FDXM5F3 x2 18.4 - 20 - 15.6 0.094 0.4 0.034x2 0.3x2
FBA35A x2 20.6 - 25 - 15.6 0.094 0.4 0.140x2 1.2x2
50 Hz Min.198V
RZQG71L9V1 220-240V Max.264V - -
FBA71A 19.0 20 15.6 0.094 0.4 0.350 1.1
FAA71A 18.1 - 20 - 15.6 0.094 0.4 0.048 0.4
FVA71A 18.4 - 20 - 15.6 0.094 0.4 0.117 0.6
FHA35A x2 19.1 - 20 - 15.6 0.094 0.4 0,060 X 2 0,6 X 2
FHA71A 18.6 - 20 - 15.6 0.094 0.4 0.091 0.8
FUA71A 18.7 - 20 - 15.6 0.094 0.4 0.046 0.9
FCAHG100G 29.1 - 32 - 24.2 0.094+0.094 0.4+0.4 0.221 1.3

OUTDOOR
FCAG35A x3 28.6 - 32 - 24.2 0.094+0.094 0.4+0.4 0.044x3 0.3x3

UNITS
FCAG50A x2 28.3 - 32 - 24.2 0.094+0.094 0.4+0.4 0.039x2 0.3x2
FCAG100A 28.4 - 32 - 24.2 0.094+0.094 0.4+0.4 0.117 0.7
FFA35A x3 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0.050x3 0.4x3
FFA50A x2 28.5 - 32 - 24.2 0.094+0.094 0.4+0.4 0.050x2 0.4x2
FDXM35F3 x3 28.6 - 32 - 24.2 0.094+0.094 0.4+0.4 0.034x3 0.3x3
FDXM50F3 x2 28.8 - 32 - 24.2 0.094+0.094 0.4+0.4 0.06x2 0.5x2
50Hz
RZQG100L9V1 220-240V Min.198V - -
FBA35A x3 Max.264V 32.0 40 24.2 0.094+0.094 0.4+0.4 0.140x3 1.2x3
FBA50A x2 30.5 - 32 - 24.2 0.094+0.094 0.4+0.4 0.140x2 1.2x2
FBA100A 29.5 - 32 - 24.2 0.094+0.094 0.4+0.4 0.350 1.6

AIR CURTAINS
FAA100A 28.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0.064 0.4

BIDDLE
FVA100A 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0.238 1.2
FHA35A x3 29.8 - 32 - 24.2 0.094+0.094 0.4+0.4 0.060 X 3 0,6 x3
FHA50A x2 29.0 - 32 - 24.2 0.094+0.094 0.4+0.4 0,060 X 2 0,6 X 2
FHA100A 29.1 - 32 - 24.2 0.094+0.094 0.4+0.4 0.150 1.3
FUA100A 29.1 - 32 - 24.2 0.094+0.094 0.4+0.4 0.106 1.3

SYMBOLS NOTES
MCA: Min. Circuit Amps. (A) 1 RLA is based on the following conditions:
TOCA: Total Over-Current Amps. (A) Cooling
MFA: Max. Fuse Amps Indoor temperature 27.0°CDB/19.0°CWB

VENTILATION
(See note 7) (A) Outdoor temperature 35.0°CDB
MSC: Max. current during the starting compressor. (A) Heating
RLA: Rated Load Amps. (A) Indoor temperature 20.0°CDB
OFM: Outdoor Fan Motor. (A) Outdoor temperature 7.0°CDB / 6.0°CWB
IFM: Indoor Fan Motor. 2 TOCA means the total value of each OC set.
FLA: Full Load Amps. 3 Voltage range
KW Fan Motor Rated Output (kW) Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below or above listed range limits.
4 Maximum allowable voltage variation between phases is 2%.
5 MCA represents maximum input current. MFA represents capacity which may accept MCA.
(next lower standard fuse rating, min.15A)
6 Select wire size based on the larger value of MCA or TOCA.
7 MFA is used to select the circuit breaker and the ground fault circuit interrupter.
(earth leakage circuit breaker)
3D090680

RZQG71-100L9Vl

CONTROL
SYSTEMS
RZQG71-100L8Y1

Infrastructure Cooling
Compressor OFM IFM

Indoor Outdoor Power supply Voltage range MCA TOCA MFA MSC RLA kW FLA kW FLA

FCAHG100G RZQG71 L9V1 B 19,2 - 20 - 15,6 0,094 0,4 0,221 1,3


FCAG35A x3 RZQG71 L9V1 B 18,7 - 20 - 15,6 0,094 0,4 0,044 x3 0,3 x3
FCAG50A x2 RZQG71 L9V1 B 18,4 - 20 - 15,6 0,094 0,4 0,039 x2 0,3 x2

& ACCESSORIES
FCAG100A RZQG71 L9V1 B 18,5 - 20 - 15,6 0,094 0,4 0,117 0,7
FFA35A x3 RZQG71 L9V1 B 19,1 - 20 - 15,6 0,094 0,4 0,050 x3 0,4 x3
FFA50A x2 RZQG71L9V1 B 18,6 - 20 - 15,6 0,094 0,4 0,050 x2 0,4 x2

OPTIONS
Maximum: 264V
Minimum: 198V

FBA35A x3 RZQG71 L9V1 B 19,9 - 25 - 15,6 0,094 0,4 0,089 x3 0,6 x3


FBA50A x2 R ZQ G 7 1L 9V 1B 19,1 - 20 - 15,6 0,094 0,4 0,089 x2 0,6 x2
1~50Hz - -
FBA100A RZQG71 L9V1 B 18,9 20 15,6 0,094 0,4 0,127 1,0
220-240V - -
FHA35A x3 RZQG71 L9V1 B 19,9 25 15,6 0,094 0,4 0,060 x3 0,6 x3
FHA50A x2 RZQG71 L9V1 B 19,1 - 20 - 15,6 0,094 0,4 0,060 x2 0,6 x2
FHA100A RZQG71 L9V1 B 19,2 - 20 - 15,6 0,094 0,4 0,150 1,3
FUA100A RZQG71 L9V1 B 19,2 - 20 - 15,6 0,094 0,4 0,106 1,3
FAA100A RZQG71 L9V1 B 18,1 - 20 - 15,6 0,094 0,4 0,064 0,4
FVA100A RZQG71 L9V1 B 19,1 - 20 - 15,6 0,094 0,4 0,238 1,2
FDXM35F3 x3 RZQG71 L9V1 B 18,7 - 20 - 15,6 0,094 0,4 0,034 x3 0,3 x3
FDXM50F3 x2 RZQG71 L9V1 B 18 9 - 20 - 15 6 0,094 04 o 060 x2 o5 x2
FCAHG71G x2 RZQG100L9V1B 28,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,091 x2 0,5 x2
FCAHG140G RZQG100L9V1B 29,3 - 32 - 24,2 0.094+0.094 0.4+0.4 0,244 1,4
FCAG35A x4 RZQG100L9V1B 29,0 - 32 - 24,2 0.094+0.094 0.4+0.4 0,044 x4 0,3 x4
FCAG50A x3 RZQG100L9V1B 28,6 - 32 - 24,2 0.094+0.094 0.4+0.4 0,039 x3 0,3 x3
FCAG71A x2 RZQG100L9V1B 28,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,054 x2 0,4 x2
FCAG140A RZQG100L9V1B 28,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,168 1,0
FFA35A x4 RZQG100L9V1B 29,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,050 x4 0,4 x4
- -
& PLATFORMS

FFA50A x3 RZQG100L9V1B 29,0 32 24,2 0.094+0.094 0.4+0.4 0,050 x3 0,4 x3


- -
Maximum: 264V
Minimum: 198V

FBA35A x4 RZQG100L9V1B 30,5 32 24,2 0.094+0.094 0.4+0.4 0,089 x4 0,6 x4


FBA50A x3 RZQG100L9V1B 29,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,089 x3 0,6 x3
1~50Hz - -
TOOLS

FBA71A x2 RZQG100L9V1B 28,8 32 24,2 0.094+0.094 0.4+0.4 0,070 x2 0,5 x2


220-240V - -
FBA140A RZQG100L9V1B 29,4 32 24,2 0.094+0.094 0.4+0.4 0,187 1,5
FHA35A x4 RZQG100L9V1B 30,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,060 x4 0,6 x4
FHA50A x3 RZQG100L9V1B 29,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,060 x3 0,6 x3
FHA71A x2 RZQG100L9V1B 29,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,091 x2 0,8 x2
FHA140A RZQG100L9V1B 29,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,150 1,8
FUA71A x2 RZQG100L9V1B 29,8 - 32 - 24,2 0.094+0.094 0.4+0.4 0,046 x2 0,9 x2
FAA71A x2 RZQG100L9V1B 28,5 - 32 - 24,2 0.094+0.094 0.4+0.4 0,048 x2 0,4 x2
FVA140A RZQG100L9V1B 29,3 - 32 - 24,2 0.094+0.094 0.4+0.4 0,276 1,4
FDXM35F3 x4 RZQG100L9V1B 29,0 - 32 - 24,2 0.094+0.094 0.4+0.4 0,034 x4 0,3 x4
FDXM50F3 x3 RZQG100L9V1B 29 4 - 32 - 24 2 0.094+0.094 0.4+0.4 0,060
o x3
x3 0,5 x3

Symbols

MCA: Minimum Circuit Ampere [A]


TOCA: Total overcurrent amps [A]
MFA: Maximum Fuse Ampere [A]
MSC: Maximum current of the starting compressor [A]
RLA: Rated load amps [A]
OFM: Outdoor fan motor
TECHNICAL
DRAWINGS

IFM: Indoor fan motor [A]


kW: Fan motor rated output [kW]

Notes

1. The RLA is based on the following conditions.


Cooling
Indoor temperature 27.0°C DB/ 19.0°C WB
Outdoor temperature 35.0°C DB
Heating
Indoor temperature 20.0°C DB
Outdoor temperature 7.0°C DB/ 6.0°C WB
2. TOCA is the total value of each overcurrent set.
3. Voltage range
The units are suitable for use with electrical systems in which the voltage supplied to the unit terminals is not below or above the listed range limits.
4. The maximum allowable voltage that is unbalanced between phases is 2%.
5. MCA is the maximum input current.
The capacity of the MFA must be greater than that of the MCA.
Select the MFA according to the table.
6. Select the wire size according to the MCA.
PREVIOUS

7. MFA is used to select the circuit breaker and the ground fault circuit interrupter.
3D098291

231
VIEW ALL RZQG-L8Y1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZQG100-125L8Y1
RZQG100-125L8Y1
Unit combination Minimum Ssc value [kVA]
FFA35A x3 936
FFA50A x2 951
FFA35A x3 977
FHA50A x2 936
FBA35A x3 1092
FBA50A x2 1014
FCAG35A x3 915
FCAG50A x2 RZQG100L8Y1B 899
FBA100A x1 962
FCAG100A x1 905
FCAHG100G x1 941
FAA100A x1 884
FVA100A x1 936
FHAG100G x1 936
FUA100A x1 925
FFA35A x4 962
FFA50A x3 993
FFA60A x2 951
FHA35A x4 1014
FHA50A x3 977
FHA60A x2 936
FBA35A x4 1170
FBA50A x3 1092
FBA60A x2 1003
FCAG35A x4 RZQG125L8Y1B 936
FCAG50A x3 915
FCAG60A x2 899
FBA125A x1 993
FCAG125A x1 925
FCAHG125G x1 951
FVA125A x1 936
FCAHG125G x1 962
FUA125A x1 925
FDA125A x1 993

3D079056

I NOTES
- In accordance with EN/IEC 61000-3-12(1), it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Ssc(2) ≥ minimum Ssc value.
- (1) European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase.
(2) Short-circuit power

RZQG100-140L(8)Y1

RZQG100-140L(8)Yl

Unit combination restrictions Power supply COMP OFM IFM


Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA kW FLA
3xFBA35A RZQG100L8Y18 18.7 20 - 14.2
0.094 +
0.4 + 0.4 3x0.089 3x0.6
0.094

FBA125A RZQG125L8Y18 18,5 20 - 14,2


0.094 +
0.4 + 0.4 0,187 1,5
0.094

2xFBA60A RZQG125L8Y18 18 20 - 14,2


0.094 +
0.4 + 0.4 2x0.07 2x0.5
0.094

3xFBA50A RZQG125L8Y18 18,8 20 - 14,2


0.094 +
0.4 + 0.4 3x0.089 3x0.6
0.094
MAX. 50Hz
4xFBA35A RZQG125L8Y18
3N~ 380- 456V
19,4 20 - 14,2
0.094 +
0.4 + 0.4 4x0.089 4x0.6
50Hz 415V MIN. 50Hz 0.094
342V
FBA140A RZQG140L7Y18 18,5 20 - 14,2
0.094 +
0.4 + 0.4 0,187 1,5
0.094

2xFBA71A RZQG140L7Y18 18 20 - 14,2


0.094 +
0.4 + 0.4 2x0.07 2x0.5
0.094

3xFBA50A RZQG140L7Y18 18,8 20 - 14,2


0.094 +
0.4 + 0.4 3x0.089 3x0.6
0.094

4xFBA35A RZQG140L7Y18 19,4 20 - 14.2


0.094 +
0.4 + 0.4 4x0.089 4x0.6
0.094
Notes
1 The RLA is based on the following conditions.
Indoor temperature 27°C DB / 19°C WB
Outdoor temperature 35°C DB
2 Select the wire size according to the MCA.
3 The maximum allowable voltage that is unbalanced between phases is 2%.
4 Use a circuit breaker instead of a fuse.

Symbols
1 Hz OFM Outdoor fan motor
2 Voltage IFM Indoor fan motor
3 Voltage range FLA Full Load Ampere (A)
MCA Minimum Circuit Ampere (A) kW Fan motor rated output [kW]
MFA Maximum Fuse Ampere (A) RHz Rated operating frequency [Hz]
RLA Rated load amps [A] COMP Compressor

300948636

232
VIEW ALL RZQG-L8Y1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQG100-140L(8)Y1
RZQG100-140L(8)Yl

Unit combination restrictions Power supply COMP OFM IFM


Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA kW FLA
- 0.094 +
3xFNA35A RZQG100L8Y1B 17,8 20 14,2 0.4 + 0.4 3x0.034 3x0.3
0.094

INDOOR
UNITS
- 0.094 +
2xFNA60A RZQG125L8Y1B 18 20 14,2 0.4 + 0.4 2x0.06 2x0.5
0.094
MAX. 50Hz - 0.094 +
3xFNA50A RZQG125L8Y1B 3N~ 380- 456V 18,5 20 14,2 0.4 + 0.4 3x0.06 3x0.5
0.094
50Hz 415V MIN. 50Hz
342V - 0.094 +
4xFNA35A RZQG125L8Y1B 18,2 20 14,2 0.4 + 0.4 4x0.034 4x0.3
0.094

- 0.094 +
3xFNA50A RZQG140L7Y1B 18,5 20 14,2 0.4 + 0.4 3x0.06 3x0.5
0.094
0.094 +

OUTDOOR
4xFNA35A RZQG140L7Y1B 18,2 20 - 14,2 0.4 + 0.4 4x0.034 4x0.3
0.094

UNITS
Notes
1 The RLA is based on the following conditions.
Indoor temperature 27°C DB/ 19°C WB
Outdoor temperature 35°C DB
2 Select the wire size according to the MCA.
3 The maximum allowable voltage that is unbalanced between phases is 2%.
4 Use a circuit breaker instead of a fuse.

AIR CURTAINS
BIDDLE
Symbols
1 Hz OFM Outdoor fan motor
2 Voltage IFM Indoor fan motor
3 Voltage range FLA Full Load Ampere (A)
MCA Minimum Circuit Ampere (A) kW Fan motor rated output [kW]
MFA Maximum Fuse Ampere (A) RHz Rated operating frequency [Hz]
RLA Rated load amps [A] COMP Compressor

3D096315C

VENTILATION
RZQG125-140L(8)Y1
RZQG125-140L(8)Y1

FCAG125A
Indoor Outdoor - Voltage range MCA

17,9
TOCA

-
MFA

20
MSC

-
Comp

RLA

14,2
kW
OFM

0.094+0.094
FLA

0.4+0.4
kW

0,106
IFM

FLA

1,1
FCAHG125G 18,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0,244 1,4
FCAG35A x4 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0.044x4 0.3x4
FCAG50A x3 17,6 - 20 - 14,2 0.094+0.094 0.4+0.4 0.039x3 0.3x3
FCAG60A x2 17,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0.044x2 0.3x2
FCAG125A 17,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,168 1,0
FFA35A x4 18,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0.05x4 0.4x4
FFA50A x3 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0.05x3 0.4x3

CONTROL
SYSTEMS
FFA60A x2 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0.05x2 0.6x2
FDXM35F3 x4 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0.034x4 0.3x4
FDXM50F3 x3 18,4 - 20 - 14,2 0.094+0.094 0.4+0.4 0.06x3 0.5x3
FDXM60F3 x2 Min. 342V 17,8 - 20 - 14,2 0.4+0.4 0.060x2 0.5x2
3N - SOHz
Max. 456V
0.094+0.094
FBA35A x4
380-415V
22,5 - 25 - 14,2 0.094+0.094 0.4+0.4 0.140x4 1.2x4
FBA50A x3 21,0 - 25 - 14,2 0.094+0.094 0.4+0.4 0.140x3 1.2x3
FBA60A x2 19,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0.350x2 1.1x2
FBA125AB 19,1 - 20 - 14,2 0.094+0.094 0.4+0.4 0,350 2,1
FDA125A 19,1 - 20 - 14,2 0.094+0.094 0.4+0.4 0,350 2,1
FVA125A 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,238 1,2
-

& ACCESSORIES
FHA35A x4 19,5 20 - 14,2 0.094+0.094 0.4+0.4 0,060 x4 0,6x4
FHA50A x3 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,060 x3 0,6x4

OPTIONS
FHA60A x2 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,091x2 0,6x3
FHA125A 18,4 - 20 - 14,2 0.094+0.094 0.4+0.4 0,150 1,5
FUA125A 18,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0,106 1,4
FCAG71A x2 17,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0.048x2 0.4x2
FCAG140A 17,9 - 20 - 14,2 0.094+0.094 0.4+0.4 0,106 1,1
FCAHG71G x2 17,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0.091x2 0.5x2
FCAHG 140G 18,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0,244 1,4
FCAG35A x4 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0.044x4 0.3x4
FCAG50A x3 17,6 - 20 - 14,2 0.094+0.094 0.4+0.4 0.039x3 0.3x3
FCAG71A x2 17,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0.054x2 0.4x2
FCAG140A 17,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,168 1,0
& PLATFORMS

FFA35AB x4 3N - SOHz Min. 342V 18,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0.05x4 0.4x4
FFA50A x3 380-415V Max. 456V 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0.05x3 0.4x3
TOOLS

FDXM35F3 x4 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0.034x4 0.3x4


FDXM50F3 x4 18,4 - 20 - 14,2 0.094+0.094 0.4+0.4 0.06x3 0.5x3
FBA35A x4 22,5 - 25 - 14,2 0.094+0.094 0.4+0.4 0.140x4 1.2x4
FBA50A x3 21,0 - 25 - 14,2 0.094+0.094 0.4+0.4 0.140x3 1.2x3
FBA71A x2 19,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0.350x2 1.1x2
FBA140A 19,1 - 20 - 14,2 0.094+0.094 0.4+0.4 0,350 2,1
FHA140A 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,150 1,8
FUA71A x2 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,046 x2 0,9x 2

SYMBOLS NOTES
MCA: Min. Circuit Amps. (A) 1 RLA is based on the following conditions:
TECHNICAL
DRAWINGS

TOCA: Total Over-Current Amps. (A) Cooling


MFA: Max. Fuse Amps Indoor temperature 27.0°CDB/19.0°CWB
(See note 7) (A) Outdoor temperature 35.0°CDB
MSC: Max. current during the starting compressor. (A) Heating
RLA: Rated Load Amps. (A) Indoor temperature 20.0°CDB
OFM: Outdoor Fan Motor. (A) Outdoor temperature 7.0°CDB / 6.0°CWB
IFM: Indoor Fan Motor. 2 TOCA means the total value of each OC set.
FLA: Full Load Amps. 3 Voltage range
KW Fan Motor Rated Output (kW) Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below or above listed range limits.
4 Maximum allowable voltage variation between phases is 2%.
5 MCA represents maximum input current. MFA represents capacity which may accept MCA.
(next lower standard fuse rating, min.15A)
PREVIOUS

6 Select wire size based on the larger value of MCA or TOCA.


7 MFA is used to select the circuit breaker and the ground fault circuit interrupter.
(earth leakage circuit breaker) 3D077810B

233
VIEW ALL RZQG-L8Y1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZQG125-140L(8)Yl

RZQG125-140L(8)Y1

Infrastructure Cooling
Compressor OFM IFM

Indoor Outdoor Power supply Voltage range MCA TOCA MFA MSC RLA kW FLA kW FLA

FCAHG71G x2 RZQG125L8Y1B 17,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,091 x2 0,5 x2


FCAHG140G RZQG125L8Y1B 18,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0,244 1,4
FCAG35A x4 RZQG125L8Y1B 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,044 x4 0,3 x4
FCAG50A x3 RZQG125L8Y1B 17,6 - 20 - 14,2 0.094+0.094 0.4+0.4 0,039 x3 0,3 x3
FCAG71A x2 RZQG125L8Y1B 17,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,054 x2 0,4 x2
FCAG140A RZQG125L8Y1B 17,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,168 1,0
FFA35A x4 RZQG125L8Y1B 18,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,050 x4 0,4 x4
FFA50A x3 RZQG125L8Y1B 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,050 x3 0,4 x3

Minimum: 342V
Maximum 456V
FBA35A x4 RZQG125L8Y1B 19,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,089 x4 0,6 x4
FBA50A x3 RZQG125L8Y1B 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,089 x3 0,6 x3
3N~50Hz - -
FBA71A x2 RZQG125L8Y1B 17,8 20 14,2 0.094+0.094 0.4+0.4 0,070 x2 0,5 x2
380-415V - -
FBA140A RZQG125L8Y1 B 18,4 20 14,2 0.094+0.094 0.4+0.4 0,187 1,5
FHA35A x4 RZQG125L8Y1B 19,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,060 x4 0,6 x4
FHA50A x3 RZQG125L8Y1B 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,060 x3 0,6 x3
FHA71A x2 RZQG125L8Y1B 18,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,091 x2 0,8 x2
FHA140A RZQG125L8Y1B 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,150 1,8
FUA71A x2 RZQG125L8Y1 B 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,046 x2 0,9 x2
FAA71AB x2 RZQG125L8Y1B 17,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,048 x2 0,4 x2
FVA140A RZQG125L8Y1B 18,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0,276 1,4
FDXM35F3 x4 RZQG125L8Y1B 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,034 x4 0,3 x4
FDXM50F3 x3 RZQG125L8Y1B 18,4 - 20 - 14,2 0.094+0.094 0.4+0.4 0,060 x3 O,5 x3
FCAHG71G x2 RZQG140L7Y1B 17,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,091 x2 0,5 x2
FCAHG140G RZQG140L7Y1B 18,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0,244 1,4
FCAG35A x4 RZQG140L7Y1B 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,044 x4 0,3 x4
FCAG50AB x3 RZQG140L7Y1B 17,6 - 20 - 14,2 0.094+0.094 0.4+0.4 0,039 x3 0,3 x3
FCAG71A x2 RZQG140L7Y1 B 17,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,054 x2 0,4 x2
FCAG140A RZQG140L7Y1 B 17,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,168 1,0
FFA35A x4 RZQG140L7Y1B 18,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,050 x4 0,4 x4
FFA50A x3 RZQG140L7Y1 B 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,050 x3 0,4 x3
- -
Minimum: 342V
Maximum 456V

FBA35A x4 RZQG140L7Y1 B 19,5 20 14,2 0.094+0.094 0.4+0.4 0,089 x4 0,6 x4


FBA50A x3 RZQG140L7Y1 B 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,089 x3 0,6 x3
3N~50Hz - -
FBA71A x2 RZQG140L7Y1 B 17,8 20 14,2 0.094+0.094 0.4+0.4 0,070 x2 0,5 x2
380-415V - -
FBA140A RZQG140L7Y1 B 18,4 20 14,2 0.094+0.094 0.4+0.4 0,187 1,5
FHA35A x4 RZQG140L7Y1 B 19,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,060 x4 0,6 x4
FHA50A x3 RZQG140L7Y1 B 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,060 x3 0,6 x3
FHA71A x2 RZQG140L7Y1 B 18,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,091 x2 0,8 x2
FHA 140A RZQG140L7Y1 B 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,150 1,8
FUA71A x2 RZQG140L7Y1 B 18,8 - 20 - 14,2 0.094+0.094 0.4+0.4 0,046 x2 0,9 x2
FAA71A x2 RZQG140L7Y1 B 17,5 - 20 - 14,2 0.094+0.094 0.4+0.4 0,048 x2 0,4 x2
FVA140A RZQG140L7Y1 B 18,3 - 20 - 14,2 0.094+0.094 0.4+0.4 0,276 1,4
FDXM35F3 x4 RZQG140L7Y1 B 18,0 - 20 - 14,2 0.094+0.094 0.4+0.4 0,034 x4 0,3 x4
FDXM50F3 x3 RZQG140L7Y1B 18 4 - 20 - 14,2 0.094+0.094 0.4+0.4 0,060 x3 O,5 x3

Symbols
MCA: Minimum Circuit Ampere [A]
TOCA: Total overcurrent amps [A]
MFA: Maximum Fuse Ampere [A]
MSC: Maximum current of the starting compressor [A]
RLA: Rated load amps [A]
OFM: Outdoor fan motor
IFM: Indoor fan motor
FLA: Full Load Ampere [A]
kW: Fan motor rated output [kW]

Notes
1. The RLA is based on the following conditions.
Cooling
Indoor temperature 27.0°C DB/ 19.0°C WB
Outdoor temperature 35.0°C DB
Heating
Indoor temperature 20.0°C DB
Outdoor temperature 7.0°C DB/ 6.0°C WB
2. TOCA is the total value of each overcurrent set.
3. Voltage range
The units are suitable for use with electrical systems in which the voltage supplied to the unit terminals is not below or above the listed range limits.
4. The maximum allowable voltage that is unbalanced between phases is 2%.
5. MCA is the maximum input current.
The capacity of the MFA must be greater than that of the MCA.
Select the MFA according to the table.
6. Select the wire size according to the MCA.
7. MFA is used to select the circuit breaker and the ground fault circuit interrupter.
Earth leakage circuit breaker
3D098292

234
VIEW ALL RZQG-L9V1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQG-L9V1/L8Y1

Bolt for anchor 1 Gas pipe connection ø15.9 flare


bolt4-M12
2 Liquid pipe connection - ø 9.5 flare
3 Service port (in the unit)
4 Grounding terminal M5 (in switch box)

INDOOR
UNITS
5 Refrigerant piping intake
6 Power supply wiring intake (knock out hole ø34)
7 Control wiring intake (Knock out hole ø27)
8 Drain outlet

OUTDOOR
UNITS
AIR CURTAINS
BIDDLE
VENTILATION
RZQG100-140L9V1/L8Y1

CONTROL
SYSTEMS
1 Gas pipe connection ø15.9 flare
2 Liquid pipe connection - ø9.5 flare
Bolt for anchor 3 Service port (in the unit)
bolt4-M12 4 Grounding terminal M5 (in switch box)
5 Refrigerant piping intake
6 Power supply wiring intake (knock out hole ø34)

& ACCESSORIES
7 Control wiring intake (Knock out hole ø27)
8 Drain outlet

OPTIONS
& PLATFORMS
TOOLS
1,430

TECHNICAL
DRAWINGS
PREVIOUS

235
VIEW ALL RZQG-L8Y1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQG-L9V1/L8Y1

(B) When there are obstacles on discharge sides.

• No obstacle above

Installation service space Stand-alone installation


• Obstacle on the discharge
side only
(A) When there are obstacles on suction sides.
• No obstacle above 2 Series installation (2 or more) (Note 1)
• Obstacle on the suction side only 100 or more
Stand-alone installation
• Obstacle on the suction side only 100 or more

100 or more

• Obstacle on both sides and


suction side, too
1000 or more

• Obstacle above, too.


500 or less
100 or more 1 Stand-alone installation

1000 or more
100 or more • Obstacle on the
100 or more
discharge side only,
too

2 Series installation (2 or more) (Note 1) 100 or more


• Obstacle on the suction side
100 or more
and both sides
500 or more

100 or more 2 Series installation (2 or more) (Note 1)


• Obstacle on discharge side
500 or less
300 or more

1000 or more
200 or more 100 or more

500 or less 100 or more


1000 or more

• Obstacle above, too.


Stand-alone installation
• Obstacle on the suction side, too
1000 or more

100 or more (C) When there are obstacles on both suction and
discharge sides:
500 or less
1000 or more

Pattern 1

• Obstacle on both sides and When the obstades on the discharge side is higher
suction side, too than the unit. (L > H)
(There is no limit for the height of obstructions
on the suction side.)
150 or more
• No obstacle above
150 or more
150 or more
H

Stand-alone
L

installation
• No obstacle above
100 or more
500 or more

100 or more
2 Series installation (2 or more) (Note 1)
• No obstacle above
1000 or more

2 Series installation (2 or more) (Note 1) 500 or less 100 or more


• Obstacle on the suction side and both sides 100 or more
H

100 or more
L

1000 or more

300 or more
200 or more 300 or more
1000 or more

236
VIEW ALL RZQG-L9V1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQG-L9V1/L8Y1

H 1000 or more
500 or less
• Obstacle above, too 2 Series installation (2 or more) (Note 1,2) 500 or less

INDOOR
100 or more

UNITS
Stand-alone installation (Note 2) • When there are obstacles on suction,
• When there are obstacles on discharge and top sides.
suction, discharge and top sides.
The relations between H, A

L
The relations between H, A and L are as follows.
and L are as follows.
L A
L A
L ≤1/2 H 250 or more

L
A or more

H
L ≤1/2 H 750 or more 250 or more L ≤H
L ≤H 1/2 H<L ≤H 300 or more 1500 or more
1/2 H<L ≤H 1000 or more A or more Set the stand as : L ≤H
L >H Refer
Set the stand as : L ≤H

OUTDOOR
L >H Refer to the column of L ≤H for A
to the column of L ≤H for A

UNITS
Limit of series installation is 2 units.
500 or less
2 Series installation (2 or more) (Note 1,2) 100 or more
• When there are obstacles on suction, 100 or (D) Double-decker installation
more 1000 or more
discharge and top sides. Obstacle on the discharge side. (1)

500 or more
The relations between H, A and L • Do not exceed two levels for stacked installation.

(Note3)
are as follows. • Install a roof cover similar to A (field supply),
L A as outdoor units with downward drainage
are prone to dripping and freezing. A

AIR CURTAINS
L ≤1/2 H 1000 or more • Install the upper-level outdoor unit so that
L ≤H
1/2 H<L ≤H 1250 or more
L

BIDDLE
its bottom plate is a sufficient height above
H

300 or more
Set the stand as : L ≤H
L>H Refer the roof cover. This is to prevent the buildup of 1000 or more
to the column of L ≤H for A A or more ice on the underside of the bottom plate.
Limit of series installation is 2 units.
2 Obstacle on the suction side. (1) 100 or more
Pattern 2 • Do not exceed two levels for stacked installation.
When the obstade on the discharge side is • Install a roof cover similar to A (field supply),
as outdoor units with downward drainage are

500 or more
lower than the unit (L ≤ H)

(Note3)
(There is no limit for the height of obstructions prone to dripping and freezing.
• Install the upper-level outdoor unit

VENTILATION
on the suction side.) A
so that its bottom plate is a sufficient height
• No obstacle above above the roof cover. This is to prevent the
H

300 or more
Stand-alone installation buildup of ice on the underside
L

• No obstacle above of the bottom plate.


100 or more
500 or more
(E) Multiple rows of series installation
(on the rooftop, etc.)
2 Series installation (2 or more) (Note 1,2)
One row of stand-alone
• When there are obstacles on both suction and
installation 100 or
discharge sides.

CONTROL
more

SYSTEMS
100 or more
The relations between H, A and L 100 or more
2000 or more
are as follows.
200 or more
L A
L

1000 or more
L ≤1/2 H 250 or more
1/2 H<L ≤H 300 or more 2 Rows of series installation
A or more (2 or more)
1500 or more The relations between H, A and L are as follows.
• Obstacle above

& ACCESSORIES
L A
Stand-alone installation (Note 2)

OPTIONS
L ≤1/2 H 250 or more
• When there are obstacles on L ≤H
1/2 H<L ≤H 300 or more 100 or more
suction, discharge and top sides.
H 1000 or more

500 L>H Can not be installed


or more 100 or more
100 or
more
The relations between H, A and L 100 or more

are as follows.
L A
L

L ≤1/2 H 100 or more 100 or more A or more


L ≤H
& PLATFORMS

A or more
1/2 H<L ≤H 200 or more
1000 or more
TOOLS

3000 or more
Set the stand as : L ≤H
L>H Refer to the column of L ≤H for A 100 or more
600 or more
1500 or more

NOTES
1. In case of the sideway's piping, make a 100mm gap between the unit above.
2. Close the bottom of the installation frame to prevent the discharged air from being bypassed.
3. It is not necessary to install a roof cover if there is no danger of drainage dripping and freezing.
In this case, the space between the upper and lower outdoor units should be at least 100mm.
TECHNICAL
DRAWINGS

Close off the gap between the upper and lower units so there is no reintake of discharged air.
PREVIOUS

237
VIEW ALL RZQG-L8Y1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQG-L9V1/L8Y1

To determine the additional refrigerant amount (R in kg)


3.4 Charging refrigerant (in case of twin, triple and double twin)
1 Determine
To determine G1 and G2.
the additional refrigerant amount (R in kg)
3.4
3.4.1 Charging refrigerant
Definitions: L1~L7, H1, H2 (in case of twin, triple and double twin)
G1 (m) Total length of <x> liquid piping
Pair(a) Twin(a) 1 Determine G1 and G2.
3.4.1 Definitions: L1~L7, H1, H2 x= Ø9.5 mm (standard)
L1 L2 G1 (m) Total length of <x> liquid piping
Pair(a) Twin(a) x= Ø12.7 mm (size-up)
G2 (m) x= Ø9.5
Totalmm (standard)
length of Ø6.4 mm liquid piping

H2
H1

L1 H1 L2 L3 x= Ø12.7 mm (size-up)
2 Determine R1 and R2.
G2 (m) Total length of Ø6.4 mm liquid piping

H2
L1L3
H1

If Then
H1

2 Determine R1 and R2.


L1 G1>30 m(a) Use the table below to determine
Triple(a) Double twin(a) If = G1−30m)(a)
R1 (length Then
L2 G1>30 m (a)
Use the table below=toG2).
and R2 (length determine
Triple(a) Double twinL4
(a)
R1 (length G1−30m)(a)
G1≤30 m(a) R1=0.0=kg.
L2 L3 and Use
R2 (length = G2).
the table below to determine
L2 L4 L5 (and G1+G2
H2

G1≤30 m(a) R2 (length


R1=0.0 kg. = G1+G2−30 m)(a).
H1

H2

L3 L4 Use the table below to determine


L2 L5 L6 (and G1+G2
(a) In case of size-up: Replace 30 m by 15 m.
H1
H2

R2 (length = G1+G2−30 m)(a).


H1

L1
H2

L4 L3 L6 L7 In case of standard liquid pipe size:


(a) In case of size-up: Replace 30 m by 15 m.
H1

Length
L1 L1
L3 L7 In case of standard liquid pipe size:
0~10 m 10~20 m 20~30 m(a) 30~45 m(a)
Length
(a) Assume that the longest L1line in the illustration corresponds R1: 0.5 kg 1.0 kg 1.5 kg 2.0 kg
with the actual longest pipe, and the highest unit in the 0~10 m 10~20 m 20~30 m(a) 30~45 m(a)
R2: 0.3 kg 0.6 kg 0.9 kg 1.2 kg
illustration corresponds with the actual highest unit. R1: 0.5 kg 1.0 kg 1.5 kg 2.0 kg
(a) Assume that the longest line in the illustration corresponds In case of size-up liquid pipe size:
L1 Main piping
with the actual longest pipe, and the highest unit in the R2: 0.3 kg 0.6 kg 0.9 kg 1.2 kg
L2~L7 Branch piping Length
illustration corresponds with the actual highest unit.
H1 Height difference between the highest indoor unit and In case of size-up liquid pipe size:
L1 Main piping
the outdoor unit 0~5 m 5~10 m 10~15 m(a) 15~20 m(a)
L2~L7 Branch piping Length
H2 Height difference between the highest and
H1 Height difference between the highest indoor unit and R1, R2: 0.5 kg 1.0 kg 1.5 kg 2.0 kg
thethe lowest
outdoor indoor unit
unit 0~5 m 5~10 m 10~15 m(a) 15~20 m(a)
H2 Refrigerant
Height branch
difference kit the highest and
between (a) Only for RZQG100~140.
R1, R2: 0.5 kg 1.0 kg 1.5 kg 2.0 kg
the lowest indoor unit 3 Determine the additional refrigerant amount: R=R1+R2.
3.4.2 To determine the
Refrigerant branch kit additional
refrigerant (a) Only for RZQG100~140.
Examples
amount 3 Determine the additional refrigerant amount: R=R1+R2.
3.4.2 To determine the additional refrigerant
To determine if adding additional refrigerant is necessary Examples Layout Additional refrigerant amount (R)
amount L2=7 m Case: Twin, standard liquid pipe size
If Then Layout
(Ø6.4 mm) Additional refrigerant amount (R)
To determine if adding additional refrigerant is necessary 1 G1 Total Ø9.5 => G1=35 m
L2=7L3=5
m m Case: Twin, standard liquid pipe size
(L1+L2+L3+L4+L5+L6+L7)≤ You do not have to add
If Then (Ø6.4 mm)mm)
(Ø6.4 G2 Total Ø6.4 => G2=7+5=12 m
chargeless length additional refrigerant. 1 G1 Total Ø9.5 => G1=35 m
(L1+L2+L3+L4+L5+L6+L7)≤ You do not have to add L3=5 m 2 Case: G1>30 m
Chargeless length= L1=35mm)
(Ø6.4 m (Ø9.5 mm) G2 Total Ø6.4 => G2=7+5=12 m
chargeless length additional refrigerant. R1 Length=G1−30 m=5 m
▪ 10 m (size-down) 2 Case: G1>30 m
Chargeless length= L1=35 m (Ø9.5RZQG100
mm) => R1=0.5 kg
R1 Length=G1−30 m=5 m
▪ 30 m (standard)
▪ 10 m (size-down) RZQG100 R2 Length=G2=12 m
=> R1=0.5 kg
▪ 15
▪ 30 m (size-up)
m (standard) => R2=0.6 kg
R2 Length=G2=12 m
(L1+L2+L3+L4+L5+L6+L7)> You must add additional
▪ 15 m (size-up) 3 R R=R1+R2=0.5+0.6=1.1 kg
chargeless length refrigerant. => R2=0.6 kg
(L1+L2+L3+L4+L5+L6+L7)> You must add additional L2=20 m Case: Triple, standard liquid pipe size
For future servicing, encircle the (Ø6.4 mm) 3 R R=R1+R2=0.5+0.6=1.1 kg
chargeless length refrigerant. 1 G1 Total Ø9.5 => G1=5 m
selected amount in the tables L2=20 m m
L3=17 Case: Triple, standard liquid pipe size
Forbelow.
future servicing, encircle the (Ø6.4 mm)
(Ø6.4 mm) G2 Total Ø6.4 => G2=20+17+17=54 m
selected amount in the tables 1 G1 Total Ø9.5 => G1=5 m
L3=17 m
L4=17 m 2 Case: G1≤30 m (and G1+G2>30 m)
INFORMATION below. (Ø6.4 mm)mm) G2 Total Ø6.4 => G2=20+17+17=54 m
(Ø6.4
R1 R1=0.0 kg
Piping length is the largest one way length of liquid piping. L4=17 m 2 Case: G1≤30 m (and G1+G2>30 m)
INFORMATION L1=5 m (Ø9.5 mm)
R1 R2 Length=G1+G2−30 m=5+54−30=
(Ø6.4 mm)
R1=0.0 kg
Piping length is the largest one way length of liquid piping. L1=5 m (Ø9.5 RZQG125
mm) 29 m
To determine the additional refrigerant amount (R in kg) (in R2 Length=G1+G2−30 m=5+54−30=
case of pair) 29 m=> R2=0.9 kg
RZQG125
To determine the additional refrigerant amount (R in kg) (in
L1 (m) 3 R=> R2=0.9
R=R1+R2=0.0+0.9=0.9
kg kg
case of pair)
L1 (m) 3 R R=R1+R2=0.0+0.9=0.9 kg
L1 (standard): 30~40 m 40~50 m 50~60 m(a) 60~75 m(a)
L1 (size-up):
L1 (standard): 15~20
30~40 m m40~50
20~25
m m50~60
25~30m(a)m 60~75
(a)
30~35
m(a)m
(a)

L1 (size-up): R: 0.5mkg 20~25


15~20 1.0mkg 25~301.5 kg 30~352.0
m(a) kg
m(a)
(a) Only
R: for0.5
RZQG100~140.
kg 1.0 kg 1.5 kg 2.0 kg
(a) Only for RZQG100~140.
238
VIEW ALL RZQSG-L3/L9V1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZQSG L3/9V1
RZQSG-L3_9V1
Unit combination restrictions Power supply COMP OFM IFM
RZQSG‐L3/9V1
Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA kW FLA
Unit combination restrictions Power supply COMP OFM IFM
2xFNA35A RZQSG71L3V1B 19 20 - 16,2 0,07 0,3 2x0.034 2x0.3
Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA kW FLA

22xFNQ35A2VEB RZQSG71L3V1B 19 20
28,9 - 16,2 0,07 0,3
24,4 2x0.034
0,2 2x0.3 0,6

INDOOR
xF NA 50A R ZQS G 100L 9V 1B 32 - 2x0.06 2x0.5

UNITS
2xF NQ50A2V E B R ZQS G 100L 9V 1B 28,9 32 - 24,4 0,2 0,6 2x0.06 2x0.5
3xF NA 35A R ZQS G 100L 9V 1B 28,8 32 - 24,4 0,2 0,6 3x0.034 3x0.3

3xF NQ35A 2V E B R ZQS G 100L 9V 1B 28,8 32 - 24,4 0,2 0,6 3x0.034 3x0.3
2xF NA 60A R ZQS G 125L 9V 1B MAX. 50Hz 29 32 - 24,4 0,2 0,6 2x0.06 2x0.5
2xF NQ60A2V E B R ZQS G 125L 9V 1B 3N~ MAX.
380-50Hz 456V
29 32 - 24,4 0,2 0,6 2x0.06 2x0.5
50Hz
3N~ 380- 415V
456V MIN. 50Hz
3xF NA 50A R ZQS G 125L 9V 1B 50Hz 415V MIN. 50Hz 342V 29,5 32 - 24,4 0,2 0,6 3x0.06 3x0.5
3xF NQ50A2V E B R ZQS G 125L 9V 1B 342V 29,5 32 - 24,4 0,2 0,6 3x0.06 3x0.5

4xF NA 35A R ZQS G 125L 9V 1B 29,2 32 - 24,4 0,2 0,6 4x0.034 4x0.3

OUTDOOR
4xF NQ35A2V E B R ZQS G 125L 9V 1B 29,2 32 - 24,4 0,2 0,6 4x0.034 4x0.3

UNITS
0.094- + 0.094 +
33xxFFNNAQ50AA2V E B R ZQR
SGZ1Q4S0G
L 91V410BL 9V 1B 29,5 32 29,5 - 32
24,2 0.4 +24,2 0.4 + 0.4
0.4 3x0.06 3x0.5 3x0.06 3x0.5
0.094 0.094

0.094 + 0.094 +4x0.3


44xxFFNNAQ3355AA2V E B R ZQS G 140L 9V 1B
R ZQS G 140L 9V 1B 29,2 32
29,2 - 24,2
32 0.094
0.4 4x0.034
- 0.4 +24,2 0.4 + 0.4 4x0.034 4x0.3
0.094

Notes
Notes
1 The RLA is based on the following conditions.
1 The RLAtemperature
Indoor is based on the following
27°CDB / 19°C WB.conditions.
Outdoor
Indoor temperature 35°CDB.
temperature 27°CDB / 19°C WB.

AIR CURTAINS
2 Select the wire size according to the MCA.
Outdoor temperature 35°CDB.
3 The maximum allowable voltage that is unbalanced between phases is 2%.
2 Select the wire size according to the MCA.

BIDDLE
4 Use a circuit breaker instead of a fuse.
3 The maximum allowable voltage that is unbalanced between phases is 2%.
4 Use a circuit breaker instead of a fuse.
Symbols
① Hz OFM Outdoor fan motor
② Voltage IFM Indoor fan motor
Symbols
③ Voltage range FLA Full Load Ampere (A)
① Hz OFM Outdoor fan motor
MCA Minimum Circuit Ampere (A) kW Fan motor rated output [kW]
② Voltage Indoor
IFMoperating fan motor
MFA Maximum Fuse Ampere (A) RHz Rated frequency [Hz]
③ Voltage range
RLA Rated load amps [A]  COMP Compressor 
FLA Full Load Ampere (A) 3D096315C
MCA Minimum Circuit Ampere (A) kW Fan motor rated output [kW] 3D096315C

VENTILATION
RZQSG71-100L3_9V1
MFA Maximum Fuse Ampere (A) RHz Rated operating frequency [Hz]
RZQSG71-100L3_9V1
RLA Rated load amps [A] COMP Compressor
Comp OFM IFM 3D096315C

Indoor Outdoor Hz-Power Voltage MCA TOCA MFA MSC RLA kW FLA kW FLA
suppy range

FCAHG125G 29.3 - 32 - 24.4 0.2 0.6 0.244 1.4


FCAG35A x4 29.0 - 32 - 24.4 0.2 0.6 0.044 x4 0.3 x4
FCAG50A x3 28.6 - 32 - 24.4 0.2 0.6 0.039 x3 0.3 x3
FCAG60A x2 28.3 - 32 - 24.4 0.2 0.6 0.044 x2 0.3 x2
FCAG125A 28.8 - 32 - 24.4 0.2 0.6 0.168 1.0
FFA35A x4 29.5 - 32 - 24.4 0.2 0.6 0.05 x4 0.4 x4
FFA50A x3 29.0 - 32 - 24.4 0.2 0.6 0.05 x3 0.4 x3

CONTROL
SYSTEMS
FFA60A x2 29.0 - 32 - 24.4 0.2 0.6 0.05 x2 0.6 x2
FDXM35F3 x4 29.0 - 32 - 24.4 0.2 0.6 0.034 x4 0.3 x4
FDXM50F3 x3 29.4 - 32 - 24.4 0.2 0.6 0.06 x3 0.5 x3
RZQSG125L9V1 50Hz Min. 198V
FDXM60F3 x2 220-240V Max. 264V 28.8 - 32 - 24.4 0.2 0.6 0.060 x2 0.5 x2
FBA35A x4 33.5 - 32 - 24.4 0.2 0.6 0.140 x4 1.2 x4
FBA50A x3 32.0 - 32 - 24.4 0.2 0.6 0.140 x3 1.2 x3
FBA60A x2 30.3 - 32 - 24.4 0.2 0.6 0.350 x2 1.1 x2
FBA125A 30.1 - 32 - 24.4 0.2 0.6 0.350 2.1
FDA125A 30.1 - 32 - 24.4 0.2 0.6 0.350 2.1
FVA125A 29.0 - 32 - 24.4 0.2 0.6 0.238 1.2

& ACCESSORIES
FHA35A x4 30.5 - 32 - 24.4 0.2 0.6 0,060 x4 0,6 x4
FHA50A x3 29.8 - 32 - 24.4 0.2 0.6 0,060 x3 0,6 x3

OPTIONS
FHA60A x2 29.0 - 32 - 24.4 0.2 0.6 0,091 x2 0,6 x2
FHA125A 29.4 - 32 - 24.4 0.2 0.6 0.150 1.5
FCAHG71G x2 28.8 - 32 - 24.4 0.094+0.094 0.4+0.4 0.091x2 0.5x2
FCAHG140G 29.3 - 32 - 24.4 0.094+0.094 0.4+0.4 0.244 1.4
FCAG35A x4 29.0 - 32 - 24.4 0.094+0.094 0.4+0.4 0.044x4 0.3x4
FCAG50A x3 28.6 - 32 - 24.4 0.094+0.094 0.4+0.4 0.039x2 0.3x3
FCAG71A x2 28.5 - 32 - 24.4 0.094+0.094 0.4+0.4 0.054x2 0.4x2
FCAG140A 28.8 - 32 - 24.4 0.094+0.094 0.4+0.4 0.168 1.0
FFA35A x4 29.5 - 32 - 24.4 0.094+0.094 0.4+0.4 0.05x4 0.4x4
FFA50A x3 29.0 - 32 - 24.4 0.094+0.094 0.4+0.4 0.05x3 0.4x3
FDXM35F3 x2 29.0 - 32 - 24.4 0.094+0.094 0.4+0.4 0.034x4 0.3x4
& PLATFORMS

FDXM50F3 x3 29.4 - 32 - 24.4 0.094+0.094 0.4+0.4 0.06x3 0.5x3


RZQSG140L9V1 50Hz Min. 198V 33.5 - 32 - 24.4 0.140x4 1.2x4
FBA35A x4 0.4+0.4
TOOLS

220-240V Max. 264V


0.094+0.094
FBA50A x3 32.0 - 32 - 24.4 0.094+0.094 0.4+0.4 0.140x3 1.2x3
FBA71A x2 30.3 - 32 - 24.4 0.094+0.094 0.4+0.4 0.350x2 1.1x2
FBA140A 30.1 - 32 - 24.4 0.094+0.094 0.4+0.4 0.350 2.1
FAA71A x2 28.5 - 32 - 24.4 0.094+0.094 0.4+0.4 0.048 x2 0.4x2
FVA140A 29.3 - 32 - 24.4 0.094+0.094 0.4+0.4 0.276 1.4
FHA35A x4 30.5 - 32 - 24.4 0.094+0.094 0.4+0.4 0,060 x4 0.6x4
FHA50A x3 29.8 - 32 - 24.4 0.094+0.094 0.4+0.4 0,060 x3 0.6x3
FHA71A x2 29.5 - 32 - 24.4 0.094+0.094 0.4+0.4 0,091 x2 0.8x2
FHA140A 29.8 - 32 - 24.4 0.094+0.094 0.4+0.4 0.15 1.8
TECHNICAL
DRAWINGS

SYMBOLS NOTES
MCA Min. Circuit Amps. (A) 1 RLA is based on the following conditions:
TOCA Total Over-Current Amps. (A) Power supply: 50Hz 230V Cooling
MFA Max. Fuse Amps. Indoor temperature 27.0°CDB/19.0°CWB
(See note 7) (A) Outdoor temperature 35.0°CDB
MSC Max. current during the starting compressor. (A) Heating
RLA Rated Load Amps. (A) Indoor temperature 20.0°CDB
OFM Outdoor Fan Motor. (A) Outdoor temperature 7.0°CDB / 6.0°CWB
IFM Indoor Fan Motor. 2 TOCA means the total value of each OC set
FLA Full Load Amps. 3 Voltage range
kW Fan Motor Rated Output (kW) Units are suitable for use on electrical systems where voltage supplied
to unit terminals is not below or above listed range limits.
4 Maximum allowable voltage variation between phases is 2%.
5 MCA represents maximum input current. MFA represents capacity which may accept MCA.
PREVIOUS

(next lower standard fuse rating, min.15A)


6 Select wire size based on the larger value of MCA or TOCA.
7 MFA is used to select the circuit breaker and the ground fault circuit interrupter.
(earth leakage circuit breaker)
3D090679
239
VIEW ALL RZQSG-L3/L9V1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
RZQSG125-140L9V1
RZQSG71-100L3_9V1
Unit combination restrictions Power supply COMP OFM IFM
Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA kW FLA

2xFBA60A RZQSG125L9V1B 29 32 - 24,4 0,2 0,6 2x0.07 2x0.5

3xFBA50A RZQSG125L9V1B 29,8 32 - 24,4 0,2 0,6 3x0.089 3x0.6

4xFBA35A RZQSG125L9V1B 30,4 32 - 24,4 0,2 0,6 4x0.089 4x0.6

MAX. 50Hz
220-
50 264V 0.094 +
FBA140A RZQSG140L9V1B 240V 29,5 32 74 24,2 0.4 + 0.4 0,187 1,5
MIN. 50Hz 0.094
198V
0.094 +
2xFBA71A RZQSG140L9V1B 29 32 - 24,2
0.094
0.4 + 0.4 2x0.07 2x0.5

0.094 +
3xFBA50A RZQSG140L9V1B 29,8 32 - 24,2 0.094 0.4 + 0.4 3x0.089 3x0.6

0.094 +
4xFBA35A RZQSG140L9V1B 30,4 32 - 24,2 0.094
0.4 + 0.4 4x0.089 4x0.6

Notes
1 The RLA is based on the following conditions.
Indoor temperature 27°C DB/ 19°C WB
Outdoor temperature 35°C DB
2 Select the wire size according to the MCA.
3 The maximum allowable voltage that is unbalanced between phases is 2%.
4 Use a circuit breaker instead of a fuse.

Symbols
1 Hz OFM Outdoor fan motor
2 Voltage IFM Indoor fan motor
3 Voltage range FLA Full Load Ampere (A)
kW Fan motor rated output (kW)
MCA Minimum Circuit Ampere (A)
RHz Rated operating frequency [Hz]
MFA Maximum Fuse Ampere (A)
COMP Compressor
RLA Rated load amps (A)
3D094863B
3D094863B

RZQSG71-100L3_9V1
Comp OFM IFM

Hz
Power
Indoor Outdoor Voltage range MCA TOCA MFA MSC RLA kW FLA kW FLA
supply

FCAHG71G 18.8 - 20 - 16.2 0.7 0.3 0.091 0.5


FCAG35A X2 18.9 - 20 - 16.2 0.7 0.3 0.044x2 0.3x2
FCAG71A 18.7 - 20 - 16.2 0.7 0.3 0.054 0.4
FFA35A X2 19.2 - 20 - 16.2 0.7 0.3 0.050x2 0.4x2
FDXM35F3 X2 50Hz Min. 198V
18.9 - 20 - 16.2 0.7 0.3 0.034x2 0.3x1
FBA35A X2 RZQSG71L3V1 220-240V Max. 264V 21.2 - 25 - 16.2 0.7 0.3 0.140x2 1.2x2
FBA71A 19.5 - 20 - 16.2 0.7 0.3 0.350 1.1
FAA71A 18.7 - 20 - 16.2 0.7 0.3 0.048 0.4
FVA71A 18.9 - 20 - 16.2 0.7 0.3 0.117 0.6
FHA35A X2 19.1 - 20 - 15.7 0.7 0.3 0.060x2 0,6x2
FHA71A 18.6 - 20 - 15.7 0.7 0.3 0.091 0.8
FCAHG100G 29.1 - 32 - 24.4 0.2 0.6 0.221 1.3
FCAG35A X3 28.6 - 32 - 24.4 0.2 0.6 0.044x3 0.3x3
FCAG50A X2 28.3 - 32 - 24.4 0.2 0.6 0.039x2 0.3x2
FCAG100A 28.4 - 32 - 24.4 0.2 0.6 0.117 0.7
FFA35A X3 29.0 - 32 - 24.4 0.2 0.6 0.05x3 0.4x3
FFA50A X2 28.5 - 32 - 24.4 0.2 0.6 0.05x2 0.4x2
FDXM35F3 X3 28.6 - 32 - 24.4 0.2 0.6 0.034x3 0.3x3
FDXM50F3 X2 28.8 - 32 - 24.4 0.2 0.6 0.06x2 0.5x2
50Hz Min. 198V
FBA35A X3 RZQSG100L9V1 220-240V Max. 264V 32.0 - 40 - 24.4 0.2 0.6 0.140x3 1.2x3
FBA50A X2 30.5 - 32 - 24.4 0.2 0.6 0.140x2 1.2x2
FBA100A 29.5 - 32 - 24.4 0.2 0.6 0.350 1.6
FAA100A 28.0 - 32 - 24.4 0.2 0.6 0.064 0.4
FVA100A 29.0 - 32 - 24.4 0.2 0.6 0.238 1.2
FHA35A x3 29.8 - 32 - 24.4 0.2 0.6 0,060x3 0,6x3
FHA50A X2 29.0 - 32 - 24.4 0.2 0.6 0,060x2 0,6x2
FHA100A 29.1 - 32 - 24.4 0.2 0.6 0.150 1.3

SYMBOLS NOTES
MCA: Min. Circuit Amps. (A) 1 RLA is based on the following conditions:
TOCA: Total Over-Current Amps. (A) Power supply: 50Hz 230V
MFA: Max. Fuse Amps. Cooling
(See note 7) (A) Indoor temperature 27.0°CDB/19.0°CWB
MSC: Max. current during the starting compressor. (A) Outdoor temperature 35.0°CDB
RLA: Rated Load Amps. (A) Heating
OFM: Outdoor Fan Motor. (A) Indoor temperature 20.0°CDB
IFM: Indoor Fan Motor. Outdoor temperature 7.0°CDB / 6.0°CWB
FLA: Full Load Amps. 2 TOCA means the total value of each OC set
kW: Fan Motor Rated Output (kW) 3 Voltage range
Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below or above listed range limits.
4 Maximum allowable voltage variation between phases is 2%.
5 MCA represents maximum input current MFA represents capacity which may accept MCA.
(next lower standard fuse rating, min.15A)
6 Select wire size based on the larger value of MCA or TOCA.
7 MFA is used to select the circuit breaker and the ground fault circuit interrupter. 3D090679
240
VIEW ALL RZQSG-L3/L9V1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQSG71L3V1

Comp OFM IFM


Indoor Outdoor Hz-Power supply Voltage range MCA TOCA MFA MSC RLA kW FLA kW FLA
FCAHG71G 18.8 - 20 - 16.2 0.07 0.3 0.091 0.5
FCAG35A x2 18.9 - 20 - 16.2 0.07 0.3 0.044x2 0.3x2
FCAG71A 18.7 - 20 - 16.2 0.07 0.3 0.054 0.4

INDOOR
UNITS
FFA35A x2 19.2 - 20 - 16.2 0.07 0.3 0.055x2 0.4x2
FFA35A x2 18.9 - 20 - 16.2 0.07 0.3 0.050x2 0.3x2
FBA35A x2 50Hz Min. 198V 21.2 - 20 - 16.2 0.07 0.3 0.140x2 1.2x2
FBA71A RZQSG71L3V1
220-240V Max. 264V 19.5 - 20 - 16.2 0.07 0.3 0.350 1.1
FHA35A x2 19.7 - 20 - 16.2 0.07 0.3 0.062x2 0.6x2
FCAHG71G 19.2 - 20 - 16.2 0.07 0.3 0.091 0.8
FAA71A 18.7 - 20 - 16.2 0.07 0.3 0.048 0.4
FVA71A 18.9 - 20 - 16.2 0.07 0.3 0.117 0.6
FFA71A x2 19.2 - 20 - 16.2 0.07 0.3 0.050x2 0.4x2
FDXM35F3 x2 18.9 - 20 - 16.2 0.07 0.3 0.034x2 0.3x2

OUTDOOR
UNITS
SYMBOLS NOTES
MCA Min. Circuit Amps. (A) 1 RLA is based on the following conditions: Power supply: 50Hz 230V
TOCA Total Over-Current Amps. (A) Cooling
MFA Max. Fuse Amps. Indoor temperature 27.0°CDBl19.0°CWB
(See note 7) (A) Outdoor temperature 35.0°CDB
MSC Max. current during the starting compressor. (A) Heating
RLA Rated Load Amps. (A) Indoor temperature 20.0°CDB
OFM Outdoor Fan Motor. (A) Outdoor temperature 7.0°CDB / 6.0°CWB

AIR CURTAINS
IFM Indoor Fan Motor 2 TOCA means the total value of each OC set.
FLA Full Load Amps 3 Voltage range

BIDDLE
kW Fan Motor Rated Output. (kW) Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below orabove listed range limits.
4 Maximum allowable voltage variation between phases is 2%.
5 MCA represents maximum input current. MFA represents capacity which may accept MCA.
(next lower standard fuse rating, min.1 SA)
6 Select wire size based on the larger value of MCA or TOCA.
7 MFA is used to select the circuit breaker and the ground fault circuit interrupter.
(earth leakage circuit breaker)

VENTILATION
3D082372A

CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

241
VIEW ALL RZQSG-L3/L9V1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQSG71L3V1

Hole for anchor bolt 4-M12 1 Gas pipe connection ø 15.9 flare
2 Liquid pipe connection - ø 9.5 flare
3 Service port (in the unit)
4 Grounding terminal MS (in switch box)
5 Refrigerant piping intake
6 Power supply wiring intake (knock hole ø 34)
7 Control wiring intake (knock hole ø 27)
8 Drain outlet

RZQSG100-125L9V1/L8Y1

Bolt for anchor


bolt4-M12 1 Gas connection pipe ø15.9 flare
2 Liquid connection pipe ø9.5 flare
3 Service port (in the unit)
4 Grounding terminal M5 (in switch box)
5 Refrigerant piping intake
6 Power supply wiring intake (knock out hole ø34)
7 Control wiring intake (knock out hole ø2 7)
8 Drain outlet

242
VIEW ALL RZQSG-L(8)Y1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQSG140LY1

1 Gas connection pipe Ø15.9 flare


2 Liquid connection pipe Ø9.5 flare
3 Service port (in the unit)
Bolt for anchor
4 Grounding terminal M5 (in switch box)
bolt 4-M12

INDOOR
5 Refrigerant piping intake

UNITS
6 Power supply wiring intake (knock out hole Ø 34)
7 Control wiring intake (knock out hole Ø 27)
8 Drain outlet

OUTDOOR
UNITS
AIR CURTAINS
BIDDLE
VENTILATION
CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

243
VIEW ALL RZQSG-L3/L9V1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQSG71L3V1

A. Non stacked installation


Legend Unit: mm

Suction side obstacle

Discharge side obstacle

Left side obstacle

Right side obstacle

Top side obstacle

Obstacle is present

1 In these cases, close the bottom of


the installation frame to prevent discharged air
from being bypassed.

2 In these cases, only 2 units can be installed.

This situation is not allowed.

B. Stacked installation Figures between ( ) indicate the dimensions


1. Obstacles exist in front of the outlet side 2. Obstacles exist in front of the air inlet only for the 100-125-140 class models.

Do not stack more than one unit.


About 100mm is required as the dimension for laying the upper outdoor unit's drain pipe.
Get the portion A sealed so that air from the outlet does not bypass.

C. Multiple-row installation
1. Installation of one unit per row 2. Installing multiple units (2 units or more) in
lateral connection per row

Relation of dimensions of H, A, and L are shown in the table below.


L A
0 < L ≤ 1/2 H 150 (250)
L≤H
1/2 H<L 200 (300)
H>L Installation impossible

244
VIEW ALL RZQSG-L3/L9V1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQSG100-140L9V1

INDOOR
(B) When there are obstacles on discharge sides.

UNITS
• No obstacle above
1 Stand-alone installation

Installation service space • Obstacle on the discharge side only


The measure of these values is "mm".
(A) When there are obstacles on suction sides.

500 or more
• No obstacle above
1 Stand-alone installation 2 Series installation (2 or more) (Note 1)
• Obstacle on the suction side only • Obstacle on the discharge side only

OUTDOOR
100 or more

UNITS
100 or more

100 or more

• Obstacle on both sides and suction side, too


1000 or more

AIR CURTAINS
BIDDLE
100 or more 500 or less

1000 or more
• Obstacle above, too.
100 or more 100 or more 1 Stand-alone installation

• Obstacle on the discharge


side only, too

2 Series installation (2 or more) (Note 1) 100 or more


• Obstacle on the suction side and both sides
100 or more

VENTILATION
500 or more

1000 or more

2 Series installation (2 or more) (Note 1)


• Obstacle on the discharge side
300 or more 500 or less
200 or more

1000 or more
100 or more

CONTROL
SYSTEMS
500 or less
1000 or more

100 or more

• Obstacle above, too


1 Stand-alone installation
• Obstacle on the suction side, too
1000 or more

100 or more

& ACCESSORIES
OPTIONS
500 or less
1000 or more

(C) When there are obstacles on both suction and discharge sides:
Pattern 1
When the obstacles on the discharge side is higher than the unit. (L>H)
• Obstacle on both sides and suction side, too (There is no limit for the height of obstructions on the suction side.)
• No obstacle above
1 Stand-alone installation

150 or more • No obstacle above


& PLATFORMS

150 or more 150 or more


TOOLS

100 or more
500 or more

2 Series installation (2 or more) (Note 1)


• No obstacle above 100 or more
1000 or more

1 Series installation (2 or more) (Note 1) 500 or less


• Obstacle on the suction side and both sides 100 or more
TECHNICAL
DRAWINGS

1000 or more

300 or more
300 or more
200 or more
1000 or more

3D069554
PREVIOUS

245
VIEW ALL RZQSG-L3/L9V1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQSG100-140L9V1

2 Series installation (2 or more) (Note 1, 2)

1000 or more
500 or less • When there are obstacles on suction, 500 or less
discharge and top sides.

100 or more
• Obstacle above, too
1 Stand-alone installation (Note 2)

• When there are obstacles


The relations between H, A and L are as follows.
on suction, discharge and top sides.
L A
L ≤ 1/2H 250 or more
The relations between H, A and L are as follows. L≤H
1/2 H < L ≤ H 300 or more
L A
Set the stand as: L ≤ H A or more
L ≤ 1/2H 750 or more 250 or more L>H
L≤H Refer to the column of L ≤H for A 1500 or more
1/2 H < L ≤ H 1000 or more
A or more Limit of series installation is 2 units.
Set the stand as: L ≤ H
L>H
Refer to the column of L ≤H for A

500 or less (D) Double-decker installation 100 or more


1 Obstacle on the discharge side. (Note 1)

100 or more
2 Series installation (Note 1,2) • Do not exceed two levels for stacked installation.
• When there are obstacles on suction, • Install a roof cover similar to A (field supply),

500 or more
discharge and top sides. as outdoor units with downward drainage
are prone to dripping and freezing.

(Note 3)
The relations between H, A and L are as follows. • Install the upper-level outdoor unit
L A so that its bottom plate is a sufficient height
above the roof cover.
L ≤ 1/2H 1000 or more
L≤H This is to prevent the buildup of ice
1/2 H < L ≤ H 1250 or more on the underside of the bottom plate.
250 or more
Set the stand as: L ≤ H 1000 or more
L>H
Refer to the column of L ≤H for A A or more
Limit of series installation is 2 units.
2 Obstacle on the suction side. (Note 1) 100 or more
Pattern 2
• Do not exceed two levels for stacked installation.
When the obstade on the discharge side is • Install a roof cover similar to A (field supply),
lower than the unit (L ≤ H) as outdoor units with downward drainage

500 or more
(There is no limit for the height of obstructions are prone to dripping and freezing.

(Note 3)
on the suction side.) • Install the upper-level outdoor unit so
that its bottom plate is a sufficient height
• No obstacle above
1 Stand-alone installation
above the roof cover. This is to prevent
the buildup of ice on the underside of the bottom plate.
• No obstacle above 300 or more

100 or more (E) Multiple rows of series installation


500 or more (on the rooftop, etc.)
1 One row of stand-alone installation

100
2 Series installation (2 or more) (Note 1, 2) or more
• When there are obstacles on both 100 or more
2000 or more
suction and discharge sides.
100 or more
The relations between H, A 200 or more
and L are as follows. 1000 or more
L A
L ≤ 1/2H 250 or more 2Rows of series installation
1/2 H < L ≤ H 300 or more A or more (2 or more)
The relations between H, A and L are as follows.
1500 or more
L A
L ≤ 1/2H 250 or more
• Obstacle above, too L≤H
1 Stand-alone installation (Note 2) 1/2 H < L ≤ H 300 or more
100 or more
1000 or more

• When there are obstacles on suction, L>H Can not be installed


discharge and top sides 500 or less 100 or more

The relations between H, A and L are as follows.


L A
L ≤ 1/2H 100 or more
L≤H 100 or more A or more
1/2 H < L ≤ H 200 or more A or more
Set the stand as: L ≤ H 1000 or more 3000 or more
L>H
Refer to the column of L ≤H for A
100 or more
600 or more
1500 or more

Notes
1 In case of the sideway's piping, make a 100mm gap between the unit above.
2 Close the bottom of the installation frame to prevent the discharged air from being bypassed.
3 It is not necessary to install a roof cover if there is no danger of drainage dripping and freezing.
In this case, the space between the upper and lower outdoor units should be at least 100mm.
Close off the gap between the upper and lower units so there is no reintake of discharged air.

246
VIEW ALL AZQS-B(8)V1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

AZQS-B(8)V1
AZQS-B(8)V1
AZQS-BY1
Comp OFM IFM
Indoor Outdoor Hz ~ Power supply Voltage range MCA TOCA MFA MSC RLA KW FLA kW FLA
ACQ71DV1 AZQS71B2V1B 18.8 − 20 − 16.2 0.07 0.3 0.067 0.52
ABQ71CV1 AZQS71B2V1B 19.5 − 20 − 16.2 0.07 0.3 0.128 1.05
AHQ71CV1 AZQS71B2V1B 19.2 − 20 − 16.2 0.07 0.3 0.106 0.8

INDOOR
ACQ100DV1 AZQS100B8V1B 28.5 − 32 − 24.4 0.2 0.6 0.094 0.77

UNITS
ABQ100CV1 AZQS100B8V1B 28.6 − 32 − 24.4 0.2 0.6 0.109 0.9
AHQ100CV1 AZQS100B8V1B Min. 198V 28.9 − 32 − 24.4 0.2 0.6 0.149 1.12
50Hz ~220-240V
ACQ125DV1 AZQS125B8V1B Max. 264V 28.9 − 32 − 24.4 0.2 0.6 0.137 1.12
ABQ125CV1 AZQS125B8V1B 31.5 − 32 − 24.4 0.2 0.6 0.413 3.16
AHQ125CV1 AZQS125B8V1B 28.9 − 32 − 24.4 0.2 0.6 0.240 1.1
ABQ140CV1 AZQS140B8V1B 32.8 − 40 − 24.2 0.094+0.094 0.4+0.4 0.546 4.23
AHQ140CV1 AZQS140B8V1B 30.7 − 32 − 24.2 0.094+0.094 0.4+0.4 0.316 2.52
ACQ140DV1 AZQS140B8V1B 28.9 − 32 − 24.2 0.094+0.094 0.4+0.4 0.137 1.12
ACQ100DV1 AZQS100B7Y1B 14.2 − 16 − 11.4 0 .2 0.6 0.094 0.77

OUTDOOR
− −

UNITS
ABQ100CV1 AZQS100B7Y1B 14.3 16 11.4 0.2 0.6 0.109 0.9
AHQ100CV1 AZQS100B7Y1B 14.6 − 16 − 11.4 0.2 0.6 0.149 1.12
ACQ125DV1 AZQS125B7Y1B 14.6 − 16 − 11.4 0.2 0.6 0.137 1.12
3N~50Hz Min. 342V
ABQ125CV1 AZQS125B7Y1B 17.2 − 20 − 11.4 0.2 0.6 0.413 3.16
380-415V Max. 456V
AHQ125CV1 AZQS125B7Y1B 14.6 − 16 − 11.4 0.2 0.6 0.240 1.10
ABQ140CV1 AZQS140B7Y1B 21.8 − 25 − 14.2 0.094+0.094 0.4+0.4 0.546 4.23
AHQ140CV1 AZQS140B7Y1B 19.7 − 20 − 14.2 0.094+0.094 0.4+0.4 0.316 2.52
ACQ140DV1 AZQS140B7Y1B 17.9 − 20 − 14.2 0.094+0.094 0.4+0.4 0.137 1.12

AIR CURTAINS
Symbols

BIDDLE
MCA: Minimum Circuit Ampere (A)
TOCA: Total overcurrent amps [A]
MFA: Maximum Fuse Ampere (A)
MSC: Maximum current of the starting compressor [A]
RLA: Rated load amps [A]
OFM: Outdoor fan motor
IFM: Indoor fan motor
FLA: Full load amps
KW: Fan motor rated output [kW]

Notes
1. The RLA is based on the following conditions.
Cooling
Indoor temperature 27.0°C DB / 19.0°C WB

VENTILATION
Outdoor temperature 35.0°C DB
Heating
Indoor temperature 20.0°C DB
Outdoor temperature 7.0°C DB / 6.0°C WB
2. TOCA is the total value of each overcurrent set.
3. Voltage range
The units are suitable for use with electrical systems in which the voltage supplied to the unit terminals is not below or above the listed range limits.
4. The maximum allowable voltage that is unbalanced between phases is 2%.
5. MCA is the maximum input current.
The capacity of the MFA must be greater than that of the MCA.
Select the MFA according to the table.
The next lower standard fuse rating is minimum 15 ampere.
6. Select the wire size according to the MCA.
7. MFA is used to select the circuit breaker and the ground fault circuit interruptor.
Earth leakage circuit breaker __________ 3D090681B

CONTROL
SYSTEMS
AZQS71B2V1
AZQS71B2V1 unit (mm)

Bolt for anchor bolt 4-M12 KA Gas pipe connection Ø 15.9 flare
KB Liquid pipe connection Ø 15.9 flare
KC Service port (in the unit)

& ACCESSORIES
KD Grounding terminal M5 (in switch box)

OPTIONS
KE Refrigerant piping intake
KF Power supply wiring intake (knock hole Ø 34)
KG Control wiring intake (knock hole Ø 34)
KH Drain outlet

& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

247
VIEW ALL AZQS-BY1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

AZQS100-125B8V1/BY1

Bolt for anchor bolt 4-M12


1 Gas pipe connection Ø 15.9 flare
2 Liquid pipe connection Ø 9.5 flare
3 Service port (in the unit)
4 Grounding terminal M5 (in switch box)
5 Refrigerant piping intake
6 Power supply wiring intake (knock hole Ø 34)
7 Control wiring intake (knock hole Ø 34)
8 Drain outlet

AZQS140B8V1/BY1
AZQS140B8V1

Bolt for anchor bolt 4-M12 1 Gas pipe connection Ø 15.9 flare
2 Liquid pipe connection Ø 9.5 flare
3 Service port (in the unit)
4 Grounding terminal M5 (in switch box)
5 Refrigerant piping intake
6 Power supply wiring intake (knock hole Ø 34)
7 Control wiring intake (knock hole Ø 27)
8 Drain outlet

248
VIEW ALL AZQS-BY1 TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

AZQS-B8V1/BY1
(A) When there are obstacles on discharge sides.

• No obstacle above
Installation service space Stand-alone installation
The measure of these values is "mm". • Obstacle on the discharge side only

INDOOR
UNITS
(A) When there are obstacles on suction sides. 500 or more
• No obstacle above 2 Series installation (2 or more) (Note 1)
• Obstacle on the suction side only
Stand-alone installation 100 or more
• Obstacle on the suction side only 100 or more

100 or more

OUTDOOR
UNITS
• Obstacle on both sides and
suction side, too 1000 or more

• Obstacle above, too. 500 or less


100 or more
Stand-alone installation

1000 or more
1

100 or more
100 or more • Obstacle on the

AIR CURTAINS
discharge side only,

BIDDLE
too

2 Series installation (2 or more) (Note 1)


100 or more
• Obstacle on the suction side
and both sides 100 or more
500 or more

100 or more 2 Series installation (2 or more) (Note 1)

VENTILATION
• Obstacle on discharge side
500 or less

1000 or more
300 or more
200 or more 100 or more

500 or less 100 or more


1000 or more

• Obstacle above, too.


2 Stand-alone installation

CONTROL
SYSTEMS
• Obstacle on the suction side, too
1000 or more

(C) When there are obstacles on both suction and


100 or more discharge sides:

500 or less
Pattern 1
1000 or more

When the obstades on the discharge side is higher than the unit.

& ACCESSORIES
• Obstacle on both sides and (L > H)

OPTIONS
suction side, too (There is no limit for the height of obstructions
on the suction side.)

150 or more
• No obstacle above
Stand-alone installation
150 or more 150 or more
• No obstacle above
& PLATFORMS

100 or more
TOOLS

500 or more
2 Series installation (2 or more) (Note 1)
• Obstacle on the suction side and both sides 100 or more
Series installation (2 or more) (Note 1)
1000 or more

500 or less 2
• No obstacle above 100 or more
100 or more

100 or more
1000 or more
TECHNICAL
DRAWINGS

300 or more
300 or more 300 or more
1000 or more
PREVIOUS

249
VIEW ALL AZQS-B(8)V1 TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

AZQS-B8V1/BY1

• Obstacle above, too 500 or less 2 Series installation (2 or more) (Note 1,2) 500 or less

1000 or more
Stand-alone installation (Note 2) • When there are obstacles on suction,

100 or more
• When there are obstacles on discharge and top sides.
suction, discharge and top sides.
The relations between H, A
and L are as follows.
L A
L A
L ≤1/2 H 250 or more
L ≤1/2 H 750 or more L ≤H
L ≤H 250 or more 1/2 H<L ≤H 300 or more A or more
1/2 H<L ≤H 1000 or more
Set the stand as : L ≤H
L >H Refer 1500 or more
Set the stand as : L ≤H
L >H Refer A or more to the column of L ≤H for A
to the column of L ≤H for A
Limit of series installation is 2 units.
500 or less
100 or more
2 Series installation (2 or more) (Note 1,2) (D) Double-decker installation

1000 or more
• When there are obstacles on suction, 100 or more Obstacle on the discharge side. (1)
discharge and top sides. • Do not exceed two levels for stacked installation.

500 or more
The relations between H, A and L • Install a roof cover similar to A (field supply),

(Note3)
are as follows. as outdoor units with downward drainage are prone
L A to dripping and freezing.
L ≤1/2 H 1000 or more • Install the upper-level outdoor unit so that
L ≤H its bottom plate is a sufficient height above
1/2 H<L ≤H 1250 or more
the roof cover. This is to prevent the buildup of
Set the stand as : L ≤H
L>H Refer 300 or more
ice on the underside of the bottom plate.
to the column of L ≤H for A 1000 or more
A or more
Limit of series installation is 2 units. 2 Obstacle on the suction side. (1)
100 or more
Pattern 2 • Do not exceed two levels for stacked installation.
• Install a roof cover similar to A (field supply),
When the obstade on the discharge side is as outdoor units with downward drainage are
lower than the unit (L ≤ H)

500 or more
prone to dripping and freezing.
(There is no limit for the height of obstructions

(Note3)
• Install the upper-level outdoor unit
on the suction side.) so that its bottom plate is a sufficient height
• No obstacle above above the roof cover. This is to prevent the
buildup of ice on the underside
Stand-alone installation of the bottom plate. 300 or more
• No obstacle above
100 or more
(E) Multiple rows of series installation
500 or more
(on the rooftop, etc.)
2 Series installation (2 or more) (Note 1,2)
One row of stand-alone installation
• When there are obstacles on both suction and
discharge sides.
100 or more
100 or more
The relations between H, A and L
are as follows. 100 or more 2000 or more
L A 200 or more
L ≤1/2 H 250 or more 1000 or more
1/2 H<L ≤H 300 or more 2 Rows of series installation
A or more
(2 or more)
The relations between H, A and L are as follows.
• No obstacle above 1500 or more
L A
Stand-alone installation (Note 2) L ≤1/2 H 250 or more
• When there are obstacles on L ≤H
1/2 H<L ≤H 300 or more 100 or more
suction, discharge and top sides. L>H Can not be installed
500 or more
1000 or more

100 or more 100 or more

The relations between H, A and L 100 or more


are as follows.
L A
L ≤1/2 H 100 or more
L ≤H 100 or more
1/2 H<L ≤H 200 or more A or more A or more
Set the stand as : L ≤H
L>H Refer 1000 or more
3000 or more
to the column of L ≤H for A 100 or more
600 or more
1500 or more

NOTES
1. In case of the sideway's piping, make a 100mm gap between the unit above.
2. Close the bottom of the installation frame to prevent the discharged air from being bypassed.
3. It is not necessary to install a roof cover if there is no danger of drainage dripping and freezing.
In this case, the space between the upper and lower outdoor units should be at least 100mm.
Close off the gap between the upper and lower units so there is no reintake of discharged air.

250
VIEW ALL RZQ-C TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQ-C
RZQ-C
Unit combination Power supply Comp. OFM IFM
Indoor unit Outdoor unit Hz-volts Voltage range MCA TOAC MCA MSC RLA kW FLA kW FLA
FFA50A X4 RZQ200C7Y1B 50 - 400 16.8 - 25 - 13.3 0.75 0.7 0.055X4 0.7X4
FFA60A X3 RZQ200C7Y1B 50 - 400 16.1 - 20 - 13.3 0.75 0.7 0.055X3 0.7X3
FBA50A X4 RZQ200C7Y1B 50 - 400 16.8 - 25 - 13.3 0.75 0.7 0.085X4 0.7X4
FBA60A X3 RZQ200C1Y1B 50 - 400 16.7 - 25 - 13.3 0.75 0.7 0.125X3 0.9X3
FBA71A X3 RZQ200C7Y1B 50 - 400 16.7 - 25 - 13.3 0.75 0.7 0.125X3 0.9X3
FBA100A X2 RZQ200C7Y1B 50 - 400 16.0 - 20 - 13.3 0.75 0.7 0.135X2 1.0X2

INDOOR
- -

UNITS
FHA50A X4 RZQ200C7Y1B 50 - 400 16.4 20 13.3 0.75 0.7 0.062X4 0.6X4
FHA60A X3 RZQ200C7Y1B 50 - 400 15.8 - 20 - 13.3 0.75 0.7 0.062X3 0.6X3
FHA71A X3 RZQ200C7Y1B 50 - 400 15.8 - 20 - 13.3 0.75 0.7 0.062X3 0.6X3
FUA1OOA X2 RZQ200C7YlB 50 - 400 15.4 - 20 - 13.3 0.75 0.7 0.130X2 0.7X2
FAA71A X3 RZQ200C7YlB 50 - 400 16.1 - 20 - 13.3 0.75 0.7 0.045X3 0.7X3
FUA1OOA X2 RZQ200C7Y1B 50 - 400 16.2 - 20 - 13.3 0.75 0.7 0.090X2 1.1X2
FAA71A X3 RZQ200C7Y1B 50 - 400 14.9 - 20 - 13.3 0.75 0.7 0.043X3 0.3X3
FAA1OOA X2 RZQ200C7Y1B 50 - 400 14.8 - 20 - 13.3 0.75 0.7 0.049X2 0.4X2
FDQ200B7V3B RZQ200C7Y1B 50 - 400 14.0 - 20 - 13.3 0.75 0.7 0.650 6.8
FFA60A X4 RZQ250C7Y1B 50 - 400 Max.S0Hz415V 16.8 - 25 - 13.3 0.75 0.7 0,055X4 0.7X4
Min. 50Hz 380V
FFA60A X4 RZQ250C7Y1B 50 - 400 17.6 - 25 - 13.3 0.75 0.7 0.125X4 0.9X4
FBA125A X4 RZQ250C7Y1B 50 - 400 16.8 - 25 - 13.3 0.75 0.7 0.225X2 1.4X2
FHA60A X4 RZQ250C7Y1B 50 - 400 16.4 - 20 - 13.3 0.75 0.7 0.062X4 0.6X4
FHA125A X2 RZQ250C7Y1B 50 - 400 15.4 - 20 - 13.3 0.75 0.7 0.130X2 0.7X2
- -

OUTDOOR
FUA125A X2 RZQ250C7Y1B 50 - 400 16.2 20 13.3 0.75 0.7 0.090X2 1.1X2
FDA125A X2 RZQ250C7Y1B 50 - 400 14.0 - 20 - 13.3 0.75 0.7 0.500X2 4.2X2

UNITS
FDQ250B7V3B X2 RZQ250C7Y1B 50 - 400 14.0 - 20 - 13.3 0.75 0.7 1.000 7.6
FCAHG71G X3 RZQ200C7Y1B 50 - 400 17.3 - 20 - 13.3 0.75 0.7 0.091X3 0.5 X3
FCAHG1OOG X2 RZQ200C7Y1B 50 - 400 18.7 - 20 - 13.3 0.75 0.7 0.211X2 1.3 X2
FCAG5OA X4 RZQ200C7Y1B 50 - 400 16.9 - 20 - 13.3 0.75 0.7 0.039X4 0.3 X4
FCAG60A X3 RZQ200C7Y1B 50 - 400 16.5 - 20 - 13.3 0.75 0.7 0.044X3 0.3 X3
FCAG71A X3 RZQ200C7Y1B 50 - 400 16.9 - 20 - 13.3 0.75 0.7 0.048X3 0.4 X3
FCAG1OOA X2 RZQ200C7Y1B 50 - 400 17.2 - 20 - 13.3 0.75 0.7 0.117X2 0.7 X2
FHA5OA X4 RZQ200C7Y1B 50 - 400 17.9 - 20 - 13.3 0.75 0.7 0.060X4 0.5 X4
FHA60A X3 RZQ200C7Y1B 50 - 400 17.3 - 20 - 13.3 0.75 0.7 0.091X3 0.5 X3
FHA71A X3 RZQ200C7Y1B 50 - 400 18.4 - 20 - 13.3 0.75 0.7 0.091X3 0.8 X3
FHA1OOA X2 RZQ200C7Y1B 50 - 400 18.4 - 20 - 13.3 0.75 0.7 0.150X2 1.2X2
FUA7lA X3 RZQ200C7Y1B 50 - 400 18.0 - 20 - 13.3 0.75 0.7 0.046X3 0.7 X3
- -

AIR CURTAINS
FUA100A X3 RZQ200C7Y1B 50 - 400 17.9 20 13.3 0.75 0.7 0.106X2 1.0 X2
FAA71A X2 RZQ200C7Y1B 50 - 400 16.9 - 20 - 13.3 0.75 0.7 0.048X3 0.4 X3
- -

BIDDLE
FAA100A X2 RZQ200C7Y1B 50 - 400 16.4 20 13.3 0.75 0.7 0.064X2 0.4 X2
FCAHG125G X2 RZQ250C7Y1B 50 - 400 18.9 - 20 - 13.3 0.75 0.7 0.224X2 1.4X2
FCAG60A X4 RZQ250C7Y1B 50 - 400 16.9 - 20 - 13.3 0.75 0.7 0.044X4 0.3X4
- -
FCAG125A X2 RZQ250C7Y1B 50 - 400 18.2 20 13.3 0.75 0.7 0.106X2 1.1X2
FHA60A X2 RZQ250C7Y1B 50 - 400 17.9 - 20 - 13.3 0.75 0.7 0.091X4 0.5X4
FHA125A X2 RZQ250C7Y1B 50 - 400 19.4 - 20 - 13.3 0.75 0.7 0.150X2 1.6X2
FUA125A X2 RZQ250C7Y1B 50 - 400 18.2 - 20 - 13.3 0.75 0.7 0.106X2 1.1 X2

SYMBOLS NOTES
MCA Min. Circuit Amps. (A) 1 RLA is based on the following indoor conditions:
TOCA Total Over-Current Amps. (A) Power supply: 5OHz 400V
MFA Max. Fuse Amps (See note 7) (A) Cooling

VENTILATION
MSC Max. current during the starting compressor. (A) Indoor temperature 27.0°CDB/19.0°CWB
RLA Rated Load Amps. (A) Outdoor temperature 35.0°CDB
OFM Outdoor Fan Motor. (A) Heating
IFM Indoor Fan Motor. Indoor temperature 20.0°CDB
FLA Full Load Amps. Outdoor temperature 7.0°CDB/6.0°CWB.
kW Fan Motor Rated Output (kW) 2 TOCA means the total value of each OC set.
3 Voltage range
Units are suitable for use on electrical systems where voltage supplied
to unit terminals is not below or above listed range limits.
4 Maximum allowable voltage variation between phases is 2% .
5 MCA represents maximum input current, MFA represents capacity which may accept MCA.
(next lower standard fuse rating, min.15A).
6 Select wire size based on the larger value of MCA or TOCA.
3D056844E
7 MFA is used to select the circuit breaker and the ground fault circuit interrupter.
(earth leakage circuit breaker)

CONTROL
SYSTEMS
RZQ-C

RZQ-C
Unit combination restrictions Power supply COMP OFM IFM
RZQ-C
Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA FLA FLA

& ACCESSORIES
OPTIONS
3xFBA60A
Unit combination restrictions RZQ200C7Y1B 15.5 20 - COMP13.3 0.75OFM 0.7 3x0.07IFM3x0.5
Power supply
Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA FLA FLA
4xF B A 50A R ZQ200C 7Y 1B MAX. 50Hz 16.4 20 - 13.3 0.75 0.7 4x0.089 4x0.6
3xFBA60A RZQ200C7Y1B 3N~ 415V 15.5 20 - 13.3 0.75 0.7 3x0.07 3x0.5
400V
50Hz MIN. 50Hz
2xF B A 125A R ZQ250C 7Y 1B 380V 17 20 - 13.3 0.75 0.7 2x0.187 2x1.5
4xF B A 50A R ZQ200C 7Y 1B MAX. 50Hz 16.4 20 - 13.3 0.75 0.7 4x0.089 4x0.6
3N~ 415V
4xF B A 60A R ZQ250C 7Y 1B 400V 16 20 - 4x0.07 4x0.5
50Hz MIN. 50Hz 13.3 0.75 0.7
& PLATFORMS

2xF B A 125A R ZQ250C 7Y 1B 380V 17 20 - 13.3 0.75 0.7 2x0.187 2x1.5


TOOLS

Notes4xF B A 60A R ZQ250C 7Y 1B 16 20 - 13.3 0.75 0.7 4x0.07 4x0.5


1 The RLA is based on the following conditions.
Indoor temperature 27°CDB / 19°C WB.
Outdoor temperature 35°CDB.
Select the wire size according to the MCA.
Notes
2
1 The maximum
3 RLA is basedallowable voltage that
on the following is unbalanced between phases is 2%.
conditions.
4 Use a circuit
Indoor breaker27°CDB
temperature instead /of19°C
a fuse.
WB.
Outdoor temperature 35°CDB.
TECHNICAL
DRAWINGS

2 Select the wire size according to the MCA.


Symbols
3 The maximum allowable voltage that is unbalanced between phases is 2%.
① Hz
4 Use a circuit breaker instead of a fuse. OFM Outdoor fan motor
② Voltage IFM Indoor fan motor
③ Voltage range FLA Full Load Ampere (A)
MCASymbols
Minimum Circuit Ampere (A) kW Fan motor rated output [kW]
MFA① Maximum
Hz Fuse Ampere (A) RHz
OFM Rated
Outdooroperating frequency [Hz]
fan motor
RLA ② Voltage
Rated load amps [A] COMP
IFM Compressor
Indoor fan motor
③ Voltage range FLA Full Load Ampere (A)
MCA Minimum Circuit Ampere (A) kW Fan motor rated output [kW]
MFA Maximum Fuse Ampere (A) RHz Rated operating frequency [Hz]
PREVIOUS

RLA Rated load amps [A] COMP Compressor

3D094863B
251
VIEW ALL RZQ-C TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed
RZQ-C technical drawings

RZQ-C
Unit combination restrictions Power supply COMP OFM IFM
Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA FLA FLA

3xFNA60A RZQ200C7Y1B 15.5 20 - 13.3 0.75 0.7 3x0.06 3x0.5


MAX. 50Hz
4xFNA50A RZQ200C7Y1B 3N~ 415V 16 20 - 13.3 4x0.06 4x0.5
400V 0.75 0.7
50Hz MIN. 50Hz
380V
4xFNA60A RZQ250C7Y1B 16 20 - 13.3 0.75 0.7 4x0.06 4x0.5

Notes
1 The RLA is based on the following conditions.
Indoor temperature 27°CDB / 19°C WB.
Outdoor temperature 35°CDB.
2 Select the wire size according to the MCA.
3 The maximum allowable voltage that is unbalanced between phases is 2%.
4 Use a circuit breaker instead of a fuse.

Symbols
① Hz OFM Outdoor fan motor
② Voltage IFM Indoor fan motor
③ Voltage range FLA Full Load Ampere (A)
MCA Minimum Circuit Ampere (A) kW Fan motor rated output [kW]
MFA Maximum Fuse Ampere (A) RHz Rated operating frequency [Hz]
RLA Rated load amps [A] COMP Compressor

3D094863B
RZQ200C
RZQ200C

Unit combination restrictions Power supply COMP OFM IFM


Indoor Outdoor 1 2 3 MCA MFA RHz RLA kW FLA kW FLA

2xFBA100A RZQ200C7Y1B 16 20 - 13,3 0,75 0,7 2x0.127 2x1


MAX. 50Hz
3N~ 415V
400V
50Hz MIN. 50Hz
3xF B A 71A R ZQ200C 7Y 1B 380V 15,5 20 - 13,3 0,75 0,7 4x0.06 3x0.5

Notes
1 The RLA is based on the following conditions.
Indoor temperature 27°CDB / 19°C WB.
Outdoor temperature 35°CDB.
2 Select the wire size according to the MCA.
3 The maximum allowable voltage that is unbalanced between phases is 2%.
4 Use a circuit breaker instead of a fuse.

Symbols
① Hz OFM Outdoor fan motor
② Voltage IFM Indoor fan motor
③ Voltage range FLA Full Load Ampere (A)
MCA Minimum Circuit Ampere (A) kW Fan motor rated output [kW]
MFA Maximum Fuse Ampere (A) RHz Rated operating frequency [Hz]
RLA Rated load amps [A] COMP Compressor

3D094863B

252
VIEW ALL RZQ-C TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQ200-250C

RZQ200-250C

Minimum Ssc
Unit combination
value [kVA]

INDOOR
UNITS
FCAG50A x4 RZQ200C7Y1B -
FCAG60A x3 RZQ200C7Y1B -
FCAG71A x3 RZQ200C7Y1B -
FCAG100A x2 RZQ200C7Y1B -
FFA50A x4 RZQ200C7Y1B 1025
FFA60A x3 RZQ200C7Y1 B 1025
FBA50A x4 RZQ200C7Y1B 1025
FBA60A x3 RZQ200C7Y1B 1025

OUTDOOR
FBA71A x3 RZQ200C7Y1B 1025

UNITS
FBA100A x2 RZQ200C7Y1B -
FHA50A x4 RZQ200C7Y1B 1025
FHA60A x3 RZQ200C7Y1B -
FHA71A x3 RZQ200C7Y1B -
FHA100A x2 RZQ200C7Y1B -
FUA71A x3 RZQ200C7Y1B 1025
FUA100A x2 RZQ200C7Y1B 1025

AIR CURTAINS
FAA71A x3 RZQ200C7Y1B -

BIDDLE
FAA100A x2 RZQ200C7Y1B -
FDQ200B7V3B x1 RZQ200C7Y1B -

FCAG60A x4 RZQ250C7Y1B -
FCAG125A x2 RZQ250C7Y1B -
FFA60A x4 RZQ250C7Y1B 1025
FBA60A x4 RZQ250C7Y1B 1025
FBA125A x2 RZQ250C7Y1B 1025

VENTILATION
FHA60A x4 RZQ250C7Y1B 1025
FHA125A x2 RZQ250C7Y1B -
FUA125A x2 RZQ250C7Y1B 1025
FDA125A x2 RZQ250C7Y1B -
FDQ250B7V3B x1 RZQ250C7Y1B -

I NOTES
- In accordance with EN/IEC 61000-3-12*, it may be necessary to consult
the distribution network operator to ensure that the equipment is connected only

CONTROL
SYSTEMS
to a supply with Ssc** ≥ minimum Ssc value.
- (*) European/international technical standard setting the limits for harmonic
currents produced by equipment connected to public low-voltage system with input current >16A and ≤ 75A per phase.
- (**) Short-circuit power

& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

253
VIEW ALL RZQ-C TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

RZQ200-250C

RZQ200-250C
4-15 x 22.5 - mm - Oblong holes
(pitch of foundation bolt holes) (foundation bolt hole)

(pitch of foundation bolt holes)


6 (for 8HP)

Detail for front side

(Knock-out hole) Detail for bottom side

(Knock-out hole)

1 Liquid pipe connection port see note 2


2 Gas pipe connection port see note 2
(Knock-out hole) 3 Grounding terminal inside of switch box (M8)
4 Power cord routing hole (side) Ø 62
5 Power cord routing hole (front) Ø 45
Notes 6 Power cord routing hole (front) Ø 27
1 Detail for front side and detail for bottom side indicate 7 Power cord routing hole (bottom) Ø 65.5
the dimensions after fixing the attached piping. 8 Wire routing hole (front) Ø 27
2 Gas pipe (Heat pump type) 9 Pipe routing hole (front)
Ø 22.2 Brazing connection 10 Pipe routing hole (bottom)
RZQ200-250C Liquid pipe (Heat pump type)
(Knock-out hole)
Ø 9.5 Brazing connection … For 200-type
RZQ200-250C (Knock-out hole) Ø 12.7 Brazing connection … For 250-type
For single unit installation For installation in rows For centralized group layout 3TW29044-1
<Pattern 1> <Pattern 1> <Pattern 1>
For single unit installation For installation in rows For centralized group layout
<Pattern 1> <Pattern 1> <Pattern 1>
300 or more 300 or more 300 or more 300 or more

300 or more 300 or more 300 or more 300 or more


RZQ200-250C
RZQ200-250C
10 or more <Front> 10 or more 10 or more 20 or more <Front> 20 or more 10 or more 10 or more <Front> 20 or more 10 or more 10 or more <Front> 20 or more 10 or more
500 or more 500 or more 600 or more
For single
10 orunit
more installation
<Front> 10 or more For 10installation
or more in20 rows
or more <Front> 20 or more 10 or more 10 orFor
more centralized
<Front>group20 orlayout
more 10 or more
500 or more
10 or more
<Front>
<Front> 20 or more 10 or more
<Pattern 1> <Pattern 1> <Pattern 1>
500 or more 500 or more 600 or more 500 or more <Front>
<Pattern 2> <Pattern 2>
100 or more 100 or more
300 or more 300 or more 300 or more
<Pattern 2> <Pattern 2> 300 or more 300 or more
100 or more 100 or more 10 or more <Front> 10 or more
500 or more 10 or more 300
20 or more 10 or more
10 or more <Front> 10 or more
<Front> 500 or more 10 or more 20 or more 10 or more
50 or more 10 or more <Front>
50 or more 10 or more 50 or more 100more
10 or or more 20 or<Front>
more <Front>
100 or more 20 or more
50 or more 10 or more 10 or more <Front> 20 or more 10 or more 10 or more <Front> 20 or more 10 or more
500 or more 500 or more 500 or more 500 or more 600 or more
50 or more <Front> 50 or more <Front> 500 or more <Front>
50 or more 100 or more 100 or more 50 or more
500 or more 500Wall
or more
<Pattern 3> <Pattern 2> <Pattern 3> <Pattern 2> height unrestricted <Pattern 2>
100 or more 100 or more 100 or more 100 or more
<Pattern 3> <Pattern 3> Wall height unrestricted <Pattern 2>
300 or more 300 or more 300 or more
Wall height unrestricted <Front>
10 or more 100 or more 10 or more 100 or more
300 or more 300 or more 500 or more 10 or more 20 or more 10 or more
Wall height unrestricted

50 or more <Front> 50 or more 50 or more <Front> <Front> <Front>


<Front> 400 or more 100 or more<Front> 400 or100 or more
more 50 or more 50 or more 100 or more 50 or more 50 or more 100 or more 50 or more
500 or more 500 or more 500 or more
200 or more 200 or more 500 or more <Front>
50 or more <Front> 100 or more 50 or more 50 or more <Front> 100 or more 50 or more
<Front> 400 or more <Front> 400 or more
<Pattern 3> 200 or more <Pattern 3> 200 or more Wall height unrestricted <Pattern 2> 500 or more 500 or more <Front>
100 or more 100 or more
300 or more 300 or more 50 or more <Front> 50 or more
Wall height unrestricted
50 or more 50 or more 100 or more 100 or more 50 or more
50 or more <Front> 50 or more
50 or more 50 or more 100 or more <Unit:mm>
100 or more 50 or more

50 or more <Front> 100 or more 50 or more 50 or more <Front> 100 or more <Unit:mm>
50 or more
<Front> 400 or more <Front> 400 or more
h2

500 or more 500 or more <Front>


200 or more 200 or more
h2

<Suction side>
1500mm

<Front>

h1

<Suction side>

<Front>
1500mm

50 or more 50 or more
<Front>

500mm

Notes: 50 or more 50 or more 100 or more 100 or more 50 or more


h1

1 Heights of walls in case of Patterns 1 and 2:


<Unit:mm>
500mm

Front: 1 500 mm
Notes:
suction side:
1 500 mm of walls in case of Patterns 1 and 2:
Heights
Side: Height unrestricted.
Front: 1 500 mm
Installation space to be shown in this drawing is based on the cooling operation at 35 degrees outdoor air temperature.
h2

suction side: 500 mm


When the design
Side:outdoor air temperature exceeds 35 degrees or the load exceeds maximum ability because of much generation load of heat in all outdoor
Height unrestricted.
unit take the Installation
suction sidespace
spacetomore broadly
be shown in than the space
this drawing is to be shown
based on theincooling
this drawing.
operation at 35 degrees outdoor air temperature.
<Suction side>
1500mm

<Front>

2 If the above wall


When heights are exceeded
the design outdoorthen h 1/2 and h2/2
air temperature should
exceeds 35be addedortothe
degrees theload
frontexceeds
and suction side service
maximum ability spaces
becauserespectively as shown load
of much generation in theoffigure
heat in all outdoor
h1

on the right. unit take the suction side space more broadly than the space to be shown in this drawing.
3 When installing
2 If thetheabove
units wall
mostheights
appropriate pattern should
are exceeded then h be1/2selected
and h2/2from those
should beshown
added above
to the in order
front andtosuction
obtain side
the best fit in
service the space
spaces availableasalways
respectively shown in the figure
500mm

bearing in mind
Notes: need to leave enough space for a person to pass between units and wall and for the air to circulate freely.
on the right.
(If more units are toinstalling
1 When
3 Heights be
ofinstalled
walls the than
in case are
of
units catered
Patterns
most 1for
and
appropriatein2:the aboveshould
pattern patterns
beyour layout
selected should
from thosetake account
shown aboveof in
theorder
possibility
to obtainof short circuits.)
the best fit in the space available always
4 The units should be1installed
Front:
bearing 500 mmto
in mind theleave
needsufficient
to leave space
enough at space
the front
for for the ontosite
a person passrefrigerant
betweenpiping work
units and to and
wall be carried
for theout comfortably.
air to circulate freely.
suction
(If more side:
units500are mm
to be installed than are catered for in the above patterns your layout should take account of the possibility of short circuits.)
4 Side: Height
The units unrestricted.
should be installed to leave sufficient space at the front for the on site refrigerant piping work to be carried out comfortably.
Installation space to be shown in this drawing is based on the cooling operation at 35 degrees outdoor air temperature.
When the design outdoor air temperature exceeds 35 degrees or the load exceeds maximum ability because of much generation load of heat in all outdoor
254 unit take the suction side space more broadly than the space to be shown in this drawing.
2 If the above wall heights are exceeded then h 1/2 and h2/2 should be added to the front and suction side service spaces respectively as shown in the figure
on the right.
3 When installing the units most appropriate pattern should be selected from those shown above in order to obtain the best fit in the space available always
Technical drawings

Biddle air curtains


255
TECHNICAL TOOLS OPTIONS CONTROL BIDDLE OUTDOOR INDOOR
PREVIOUS VENTILATION SKY AIR INTRO
DRAWINGS & PLATFORMS & ACCESSORIES SYSTEMS AIR CURTAINS UNITS UNITS
VIEW ALL CYQS TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

CYQS_M_L-DK_FBN_FSN

CYQS-DK-FBN/FSN 500

CYQM-DK-FBN/FSN 250 250

CYQL-DK-FBN/FSN 40

O9.2

B
A

197
100
Suction grid
with filter

D
98

27
H

Type L H D U A B
CYQS-DK-FBN/FSN 1,000 - 1,500

U
2,000 - 2,500 270 590 93 171 119
CYQM-DK-FBN/FSN
CYQL-DK-FBN/FSN 1,000 - 1,500 370 774 124.5 245.5 200
2,000 - 2,500
CU0954X-000
REMARKS

1 The 2,500mm large devices have 3 suspension brackets, where the third bracket is mounted at half the length of the device.

CYQS_M_L-DK_CBN_CSN
CYQS-DK-CBN/CSN
CYQM-DK-CBN/CSN
CYQL-DK-CBN/CSN 500
250 250

40

O9.2
B
A

197
100

The finishing profiles are


supplied separately
Suction grid
with filter

Screw-eye M6
98

27
H

Number of suction grids per device


Device length Number Suction grid length D

1000 / 1500 1 1,000 / 1,500


G

2000 / 2500 2 1,000 / 1,250


*1 drain grid per device
D

Type L H D U A B E F G
F

CYQS-DK-CBN/CSN 1,000 - 1,500


2,000 - 2,500 270 821 93 171 119 250 411 260
CYQM-DK-CBN/CSN
E
U

CYQL-DK-CBN/CSN 1,000 - 1,500 370 1,105 124.5 245.5 200 181.5 563.5 360
2,000 - 2,500
CU0955X-000
L

REMARKS

1 The 2,500mm large devices have 3 suspension brackets, where the third bracket is mounted at half the length of the device.
2 The mounting holes for finishing profiles in a lowered ceiling (L+8) x (D+8) mm

256
VIEW ALL CYQS TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

CYQS_M_L-DK_RBN_RSN

CYQS-DK-RBN/RSN 500

CYQM-DK-RBN/RSN 250 250

No ducts are supplied


CYQL-DK-RBN/RSN
40

O9.2

B
A

INDOOR
197
100

UNITS
No ducts are supplied

The finishing profiles are


supplied separately

K
Suction grid
with filter

OUTDOOR
UNITS
D

98

27
Number of ducts per device H

Type 1000 1500 2000 2500

101.5
S

CYQS-DK-RBN/RSN
CYQM-DK-RBN/RSN 5 7 10 12
CYQL-DK-RBN/RSN 3 5 6 8
E G T

Number of suction grids per device F J

AIR CURTAINS
Device length Number Suction grid length
1000 / 1500 1 1,000 / 1,500

BIDDLE
2000 / 2500 2 1,000 / 1,250
*1 drain grid per device
Type L H D S U A B E F G J K M T
CYQS-DK-RBN/RSN 1,000 - 1,500 80- 1044-1544 1048-1548
270 561 90 171 119 92 139 260 308 Ø160
CYQM-DK-RBN/RSN 2,000 - 2,500 125 2044-2544 2048-2548

1044-1544 1048-1548
CYQL-DK-RBN/RSN 1,000 - 1,500 370
80-

U
745 200 123.5 170 360 408 Ø250 2044-2544 2048-2548
2,000 - 2,500 125 121.5 245.5 L

CU0956X-000

VENTILATION
M

REMARKS

1 The 2,500mm large devices have 3 suspension brackets, where the third bracket is mounted at half the length of the device.
2 Holes (for finishing profiles) - drain (L+8) x (E+8) mm - suction (L+8) x (G+8) mm.

CONTROL
SYSTEMS
& ACCESSORIES
OPTIONS
& PLATFORMS
TOOLS
TECHNICAL
DRAWINGS
PREVIOUS

257
Technical drawings

Ventilation
258
VIEW ALL VAM-FC TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM150FC
VAM150FA
Maintenance space for the heat exchange elements, the air filters and fans
Switch box

INDOOR
Ceiling hook

UNITS
Inspection hole 4-14x40 oval hole
285 Ø 450

269 Supply air fan

120~250
600
Maintenance over 104 120.3
149

20
67

SA OA

OUTDOOR
Supply air to room 124 164

124
Fresh air from outdoors

UNITS
288
509

560
(Outdoor air)
288

164
RA EA
Return air from room Exhaust air to outdoors
8 Sealing Sealing
8

120 104 718

20
149
Damper plate
Exhaust air fan
(Maintenance cover) Exhaust spacer

AIR CURTAINS
(Switch box)

BIDDLE
145 760 145

Ø200
Ø97
Heat exchange elements Air filters

VENTILATION
NOTE
1 Be sure to provide the inspection hole (450x450 mm) to inspect the air filters, the exchange elements and fans.

3TW27874-1

VAM250FC
VAM250FA

CONTROL
SYSTEMS
Maintenance space for the heat exchange elements, the air filters and fans
Switch box

Ceiling hook
Inspection hole
285 Ø 450 4-14x40 oval hole

269 Supply air fan


120~250
600

Maintenance over

& ACCESSORIES
149
104 120.3

OPTIONS
20
67

SA
OA
Supply air to room
124 164

124

Fresh air from outdoors


288
509

560
288

(Outdoor air)
164

RA EA
Return air from room Exhaust air to outdoors
8
& PLATFORMS

Sealing Sealing
8

120 104 718


20

TOOLS

149
Damper plate
Exhaust air fan
(Maintenance cover)
(Switch box)
145 760 145
Ø200
Ø97

TECHNICAL
DRAWINGS

Heat exchange elements Air filters

NOTE
1 Be sure to provide the inspection hole (450x450 mm) to inspect the air filters, the exchange elements and fans.

3TW27884-1
PREVIOUS

259
VIEW ALL VAM-FC TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM350FC
VAM350FB
Ceiling hook
4 – 12 x 40 oval hole

Sealing Exhaust air fan


Damper plate

RA
EA Return air from room
Exhaust air to outdoors

SA
OA Supply air to room
Fresh air from outdoors Supply air fan
(outdoor air) Switch box

Inspection hole

Maintenance space for the heat exchange


element, the air filters and fans

Heat exchange element

Maintenance cover Air Filter Switchbox

NOTES

1. Be sure to provide the inspection hole to inspect the air filters, the exchange elements and fans. 3D081162

VAM500FC
VAM500FB
Ceiling hook
4 – 12 x 40 oval hole

Sealing Exhaust air fan


Damper plate

RA
EA Return air from room
Exhaust air to outdoors

SA
OA Supply air to room
Fresh air from outdoors
(outdoor air) Switch box Supply air fan

Inspection hole

Maintenance space for the heat exchange


element, the air filters and fans

Heat exchange element

Maintenance cover Air filters Switchbox

NOTES

1. Be sure to provide the inspection hole to inspectthe air filters, the exchange elements and fans. 3D081163

260
VIEW ALL VAM-FC TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM650FC
VAM650FB
Ceiling hook
4 – 12 x 40 oval hole
Sealing
Damper plate

INDOOR
Exhaust air fan

UNITS
RA
EA Return air from room
Exhaust air to outdoors

SA
OA Supply air to room
Fresh air from outdoors Supply air fan
(outdoor air)

OUTDOOR
Switch box

UNITS
Inspection hole
Maintenance space for the heat exchange
element, the air filters and fans

AIR CURTAINS
Heat exchange element

BIDDLE
VENTILATION
Maintenance cover Air Filters Switchbox

NOTES

1. Be sure to provide the inspection hole to inspect the air filters, the exchange elements and fans. 3D081164

VAM800FC

CONTROL
VAM800FB

SYSTEMS
Ceiling hook
4 – 12 x 40 oval hole
Sealing
Damper plate

Exhaust air fan


RA
EA Return air from room

& ACCESSORIES
Exhaust air to outdoors

OPTIONS
SA
OA Supply air to room
Fresh air from outdoors Supply air fan
(outdoor air)
Switch box

Inspection hole
& PLATFORMS

Maintenance space for the heat exchange


TOOLS

element, the air filters and fans

Heat exchange element


TECHNICAL
DRAWINGS

Maintenance cover Ai Filter Switchbox

NOTES
PREVIOUS

1. Be sure to provide the inspection hole to inspect the air filters, the exchange elements and fans. 3D081165

261
VIEW ALL VAM-FC TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM1000FC
VAM1000FB
Ceiling hook
4 – 12 x 40 oval hole
Sealing
Damper plate

Exhaust air fan


RA
Return air from room
EA
Exhaust air to outdoors

SA
Supply air to room
OA
Fresh air from outdoors Supply air fan
(outdoor air)
Switch box

Inspection hole
Maintenance space for the heat exchange
element, the air filters and fans

Heat exchange element

Maintenance cover Air Filter Switchbox

NOTES

1. Be sure to provide the inspection hole to inspect the air filters, the exchange elements and fans. 3D081166

VAM1500FC
VAM1500FB
Ceiling hook
4 – 14 x 40 oval hole
Sealing Exhaust air fan (2x)
Damper plate

EA RA
Exhaust air to outdoors Return air from room

OA SA
Fresh air from outdoors Supply air to room
(outdoor air)
Switch box Supply air fan (2x)

Inspection hole
Maintenance space for the heat exchange
element, the air filters and fans

Heat exchange element

Maintenance cover Air Filter Switchbox

NOTES

1. Be sure to provide the inspection hole to inspect the air filters, the exchange elements and fans. 3D081167

262
VIEW ALL VAM-FC TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM2000FC
VAM2000FB
Ceiling hook
Sealing 4 – 14 x 40 oval hole
Damper plate
Exhaust air fan (2x)

INDOOR
UNITS
RA
EA
Exhaust air to outdoors Return air from room

SA
OA Supply air to room
Fresh air from outdoors
(outdoor air) Supply air fan (2x)

OUTDOOR
UNITS
Switch box

Inspection hole
Maintenance space for the heat exchange
element, the air filters and fans

Heat exchange element

AIR CURTAINS
BIDDLE
Maintenance cover Air Filter Switchbox

VENTILATION
VAM150FC
NOTES

1. Be sure to provide the inspection hole to inspect the air filters, the exchange elements and fans. 3D081168

VAM150FC

CONTROL
SYSTEMS
250 20m

200
15m

& ACCESSORIES
External static pressure [Pa]

OPTIONS
150 Ultra-high

10m

100
High
& PLATFORMS
TOOLS

Low 5m
50
Ø 100
Pipe length

0
0 50 100 150 200 250
TECHNICAL
DRAWINGS

Air flow rate [m³/h]

Notes
1. The fan speeds are valid for ·230·V, ·50·Hz power supply.
PREVIOUS

4D100379
263
VIEW ALL VAM-FC TECHNICAL
VAM250FC DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM250FC

250

200

Ultra-high
External static pressure [Pa]

Ø 150
150
Pipe length

High
100 40m

Low 30m

50 20m

10m

0
0 50 100 150 200 250 300
Air flow rate [m³/h]

Notes
1. The fan speeds are valid for ·230·V, ·50·Hz power supply.

4D100380

VAM350FC
VAM350FC
200 200
Ultra-high speed High speed
300

40m
150 150
External static pressure [Pa]

250
External static pressure [Pa]

200 30m
100
External static pressure [Pa]

100

UH15
H15
150
UH8 20m 50 50
15
H8
100
15
UH1
L15
10m 0 0
H1 1 8 1 8
L8 150 250 350 450 150 250 350 450
50
Air flow rate [m³/h] Air flow rate [m³/h]
L1
Ø150
100
Pipe length
0 Low speed
0 100 200 300 400 500
Air flow rate [m³/h]

Ultra-high speed
External static pressure [Pa]

High speed
Low speed

Legend
L1 = Low speed lower limit 50
L8 = Low speed factory setting
L15 = Low speed upper limit
H1 = High speed lower limit
H8 = High speed factory setting
H15 = High speed upper limit
UH1 = Ultra-high speed lower limit
UH8 = Ultra-high speed factory setting
UH15 = Ultra-high speed upper limit

Notes 0
1 8 15
150 250 350 450
1. The fan speeds are valid for ·230·V, ·50·Hz power supply. Air flow rate [m³/h]

264 3D100381
VIEW ALL VAM-FC TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings
VAM500FC
VAM500FC

200
Ø 200 200
Pipe length Ultra-high speed 200
High speed
50m

INDOOR
External static pressure [Pa]
150

UNITS
150
UH15 150
External static pressure [Pa]

40m

External static pressure [Pa]


UH8

H8 H15
100 UH1 30m
100
100

20m

50 L8 H1
L15

10m 50 50

OUTDOOR
L1

UNITS
0
100 200 300 400 500 600 700 15 0
0
Air flow rate [m³/h] 1 8 1 8 15
200 300 400 500 600 700 200 300 400 500 600 700
Air flow rate [m³/h] Air flow rate [m³/h]
Ultra-high speed
High speed 100
Low speed Low speed

Legend

AIR CURTAINS
L1 = Low speed lower limit
External static pressure [Pa]

L8 = Low speed factory setting

BIDDLE
L15 = Low speed upper limit
H1 = High speed lower limit
H8 = High speed factory setting 50
H15 = High speed upper limit
UH1 = Ultra-high speed lower limit
UH8 = Ultra-high speed factory setting
UH15 = Ultra-high speed upper limit

Notes
1. The fan speeds are valid for ·230·V, ·50·Hz power supply.

VENTILATION
0
1 8 15
200 300 400 500
Air flow rate [m³/h]

3D100382

VAM650FC
VAM650FC

CONTROL
SYSTEMS
60m 250 250
300
Ultra-high speed High speed
50m
250
200 200

40m
External static pressure [Pa]

200
External static pressure [Pa]
External static pressure [Pa]

150 150

& ACCESSORIES
UH15
150 30m

OPTIONS
UH1
H15 UH8

L15 20m 100 100


100

H8
L8 H1 10m
50
50 50
L1
Ø200
15
Pipe length
0
0
& PLATFORMS

0 200 400 600 800 0


1 8 8 15
Air flow rate [m³/h] 1
250 350 450 550 650 750 850 250 350 450 550 650 750 850
TOOLS

Air flow rate [m³/h] Air flow rate [m³/h]


150
Ultra-high speed Low speed
High speed
Low speed

Legend
L1 = Low speed lower limit
External static pressure [Pa]

L8 = Low speed factory setting 100

L15 = Low speed upper limit


TECHNICAL
DRAWINGS

H1 = High speed lower limit


H8 = High speed factory setting
H15 = High speed upper limit
UH1 = Ultra-high speed lower limit
50
UH8 = Ultra-high speed factory setting
UH15 = Ultra-high speed upper limit

Notes
1. The fan speeds are valid for ·230·V, ·50·Hz power supply.
0
PREVIOUS

1 8 15
250 450 650 850
3D100383
Air flow rate [m³/h]

265
VIEW ALL VAM-FC TECHNICAL
DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM800FC
VAM800FC

300 200
400 Ultra-high speed High speed

250
350
150

External static pressure [Pa]


300 200

External static pressure [Pa]


External static pressure [Pa]

250 UH8 100


150
H15 UH15
200 H8
100m
L15 100 50
150 UH1 80m

60m
100 50
L8 0
H1 40m 15

50 L1
20m 0
1 700 8 900 15 1100
300 500 700 1 900 8 1100 300 500
Ø250
Air flow rate [m³/h] Air flow rate [m³/h]
0 Pipe length
0 200 400 600 800 1000 300
Air flow rate [m³/h] Low speed
Ultra-high speed
High speed 250
Low speed
Legend
External static pressure [Pa]

L1 = Low speed lower limit 200

L8 = Low speed factory setting


L15 = Low speed upper limit
H1 = High speed lower limit 150
H8 = High speed factory setting
H15 = High speed upper limit
100
UH1 = Ultra-high speed lower limit
UH8 = Ultra-high speed factory setting
UH15 = Ultra-high speed upper limit
50

Notes
1. The fan speeds are valid for ·230·V, ·50·Hz power supply. 0 1 8 15
300 500 700 900 1100
Air flow rate [m³/h]
3D100384

VAM800FC
VAM1000FC
300 200
400 Ultra-high speed High speed

250
350
150
External static pressure [Pa]

300 200
External static pressure [Pa]
External static pressure [Pa]

250 UH8 100


150
H15 UH15
200 H8
100m
L15 100 50
150 UH1 80m

60m
100 50
L8 0
H1 40m 15

50 L1
20m 0
1 700 8 900 15 1100
300 500 700 1 900 8 1100 300 500
Ø250
Air flow rate [m³/h] Air flow rate [m³/h]
0 Pipe length
0 200 400 600 800 1000 300
Air flow rate [m³/h] Low speed
Ultra-high speed
High speed 250
Low speed
Legend
External static pressure [Pa]

L1 = Low speed lower limit 200

L8 = Low speed factory setting


L15 = Low speed upper limit
H1 = High speed lower limit 150
H8 = High speed factory setting
H15 = High speed upper limit
100
UH1 = Ultra-high speed lower limit
UH8 = Ultra-high speed factory setting
UH15 = Ultra-high speed upper limit
50

Notes
1. The fan speeds are valid for ·230·V, ·50·Hz power supply. 0 1 8 15
300 500 700 900 1100
Air flow rate [m³/h]
3D100384

266
VIEW ALL VAM-FC TECHNICAL

SKY AIR INTRO


DRAWINGS ON MY.DAIKIN.EU
Detailed technical drawings

VAM1500FC
VAM800FC

300 200
400 Ultra-high speed High speed

250
350
150

INDOOR
UNITS
External static pressure [Pa]
300 200

External static pressure [Pa]


External static pressure [Pa]

250 UH8 100


150
H15 UH15
200 H8
100m
L15 100 50
150 UH1 80m

60m

OUTDOOR
100 50

UNITS
L8 0
H1 40m 15

50 L1
20m 0
1 700 8 900 15 1100
300 500 700 1 900 8 1100 300 500
Ø250
Air flow rate [m³/h] Air flow rate [m³/h]
0 Pipe length
0 200 400 600 800 1000 300
Air flow rate [m³/h] Low speed
Ultra-high speed
High speed 250
Low speed

AIR CURTAINS
Legend
External static pressure [Pa]

BIDDLE
L1 = Low speed lower limit 200

L8 = Low speed factory setting


L15 = Low speed upper limit
H1 = High speed lower limit 150
H8 = High speed factory setting
H15 = High speed upper limit
100
UH1 = Ultra-high speed lower limit
UH8 = Ultra-high speed factory setting
UH15 = Ultra-high speed upper limit
50

VENTILATION
Notes
1. The fan speeds are valid for ·230·V, ·50·Hz power supply. 0 1 8 15
300 500 700 900 1100
Air flow rate [m³/h]
3D100384

VAM2000FC
VAM2000FC

CONTROL
SYSTEMS
300 300
300
Ultra-high speed High speed

250 250 250

200 200 200

& ACCESSORIES
External static pressure [Pa]
External static pressure [Pa]

External static pressure [Pa]

UH15

OPTIONS
150 150 150
UH8 H15
H8

100 100
100
L15 UH1
H1
50 50
50
L8

L1
& PLATFORMS

0 15 0
0 1 8 15
1200 1700 2200 1 8 2700 1200 1700 2200 2700
TOOLS

1000 1500 2000 2500

Air flow rate [m³/h] Air flow rate [m³/h] Air flow rate [m³/h]
160
Low speed
Ultra-high speed 140
High speed
Low speed
120
Legend
External static pressure [Pa]

L1 = Low speed lower limit 100


L8 = Low speed factory setting
TECHNICAL
DRAWINGS

L15 = Low speed upper limit


80
H1 = High speed lower limit
H8 = High speed factory setting
H15 = High speed upper limit 60
UH1 = Ultra-high speed lower limit
UH8 = Ultra-high speed factory setting 40
UH15 = Ultra-high speed upper limit
20

Notes
1. The fan speeds are valid for ·230·V, ·50·Hz power supply. 15
PREVIOUS

0 1 8
1200 1700 2200 2700
Air flow rate [m³/h]

267
3D100387
The future is in
your hands
Define the future of A/C

Introducing the new Sky Air A-series with ultra-efficient


Bluevolution R32 technology, available in three
models: the world-class Alpha, Advance and Active.
The new Sky Air with R32 delivers future-proofed, best-in-class
climate control for your business and customers.
Design flexibility. More compact. Quieter. With an extended operating range
in all climate conditions.
Help is at hand. Quicker and easier installation and usability, even for replacement systems.
Daikin at the heart of the system. Exceptionally low running costs. Even lower
environmental impact. All thanks to Daikin’s tried, tested and trusted technology.
Geared for comfort. Optimal remote control, geared to your customers’ individual needs.

R32 is an industry revolution. Be part of it.

Get ahead of the competition. Talk to Daikin about Sky Air today.
www.daikin.eu/skyairbluevolution
Daikin Europe N.V.  Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)

Daikin Europe N.V. participates in the Eurovent Certified


Performance programme for Liquid Chilling Packages and
Hydronic Heat Pumps, Fan Coil Units and Variable Refrigerant
Flow systems. Check ongoing validity of certificate:
www.eurovent-certification.com

ECPEN18- 100 07/17 The present publication is drawn up by way of information only and does not constitute an offer binding upon
Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its
content and the products and services presented therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from
or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.

The present publication supersedes ECPEN14-115. Printed on non-chlorinated paper. Prepared by Platzer
Kommunikation, Germany.