Beruflich Dokumente
Kultur Dokumente
TECHNICAL FEATURES
Based on 32-bit DSP and adopt an advanced vector control
algorithm to realize a high-performance control.
Mode of speed control : Sensorless Vector Control, Sensor
Close Loop Vector Control, V/F Control.
Vector Control in asynchronous and permanent synchronous
motor is available feature motor parameter auto-tuning.
150% torque when at low speed (0.5) running in the
sensorless vector control mode.
Built in simple PLC function, 16 sections speed is available
Multi-language OLED could display 3 parameter groups at
the same time.
Rotating freely with “one key shuttle keyboard”.
Optimized ventilation design.
Reliable insulation design, ensure the safety of inverter.
Support the standart Modbus communication protocol.
Strengthened coating, adapt to tough environment.
Unique EMC design, minimized the radiating interference
to power grid.
CAPACITY RANGE
Power Range : 0.75 kW - 550 kW
Frequency Range : 0 ~ 400.00Hz
Voltage Range : Single Phase 220V
3-Phase 220V, 380V, 480V, and 690V
APPLICATION FIELDS
Metallurgy, petroleum, chemical, textile, building material, coal, medicine, food, paper making,
plastic, printing, hoist, washing, water supply, sewage treatment, etc
Machine Industry :
Wire drawing machine, mixer, compressor, extruder, pump, air blower, grinder, conveyor, lifting
machine, etc
19 www.fokusdrivesteknindo.co.id
CIRCUIT DIAGRAM
PI9000 Series
DC Reactor Braking Resistor
Optional
MCCB P P+ RB MOTOR
R R(L1) U(T1)
M
S(L2) V(T2)
S PI9000 3~
Earthing Earthing
(Power) Main Circuit (Motor)
Control Circuit
DI1 Input Terminal
DI1 J5
DI2 Input Terminal 3 +24V
DI2 2 PLC
DI3 Input Terminal 1 COM
DI3 2-3 Shorted Drain Output (Default)
DI4 Input Terminal 1-2 Shorted Source Output
DI4 J13
Drain Drive PG Communication
COM Interface
Source Drive
+24V J12
E(PE)
485 Communication
Interface
+10V
VR SPA
J3
AI2 3
1K/2W shorted 0~+10V DC (Default) Output Signal 1
2
GND 1 shorted 0~20mA DC COM
SPB
E(PE) Output Signal 2
COM
+10V J4
VR 3 shorted 0~+10V DC (Default)
AI2 2
1K/2W 1 shorted 0~20mA DC
GND
E(PE)
TA1 Output Signal 3
TB1
5A / 250VAC
TC1
5A / 30VDC
Below 11 kW
20 www.fokusdrivesteknindo.co.id
CIRCUIT DIAGRAM
PI9000 Series
DC Reactor Braking Resistor
Optional
MCCB P P+ RB MOTOR
R R(L1) U(T1)
M
S(L2) V(T2)
S PI9000 3~
Earthing Earthing
(Power) Main Circuit (Motor)
Control Circuit
DI1 Input Terminal
DI1
DI2 Input Terminal J6
DI2 3 +24V J13
DI3 Input Terminal 2 DCOM PG Communication
DI3 1 COM Interface
DI4 Input Terminal
DI4 J12
Drain Drive
COM
Source Drive J5 485 Communication
+24V 3 +24V Interface
2 PLC
E(PE) 1 COM
DI5 Input Terminal 2-3 Shorted Drain Output (Default)
DI5 1-2 Shorted Source Output
DI6 Input Terminal
DI6
DI7 Input Terminal
DI7
DI8 Input Terminal
DI8
+10V
VR SPA
J3
AI2 3
1K/2W shorted 0~+10V DC (Default) Output Signal 1
2
GND 1 shorted 0~20mA DC COM
SPB
E(PE) Output Signal 2
COM
+10V J4
VR 3 shorted 0~+10V DC (Default)
AI2 2 TA1
1K/2W 1 shorted 0~20mA DC Output Signal 3
GND TB1
5A / 250VAC
TC1
E(PE) 5A / 30VDC
TA2 Output Signal 4
TB2
5A / 250VAC
TC2
5A / 30VDC
11 kW ~ 355 kW
21 www.fokusdrivesteknindo.co.id
SPECIFICATION and SIZE
Shape Dimensions Installation Dimensions
Power Voltage Current (mm) (mm) Structure
Model (KW) (V) I/O (A) Item
L W H a b d
PI9100-0R7G3 0.75 380 2.1
PI9100-1R5G3 1.5 380 3.8 180 120 178.5 174 108 Ø5.3 9S2
PI9100-7R5G3/7R5F3 7.5 380 17 285 180 200 272 138 Ø10 9S4
PI9200-055G3/075F3 55/75 380 110/150 660 364 280 640 250 Ø10 9L4
PI9300-200G3/220F3 200/220 380 380/426 1300 600 380 550 280 Ø13 9C1
PI9300-220G3/250F3 220/250 380 426/465 1540 525 421 464.5 367 Ø13 9C2
22 www.fokusdrivesteknindo.co.id
SPECIFICATION and SIZE
W
b
d
W
b
P OWTR AN DI GI TAL OPERATOR
LOC A LR EMOT E T UN NIN G/ TC
W d RU N Hz
A
%
s
°C
F WD
REV
V
DIGITAL OPERATOR
POWTR AN
d L OC AL RE MO TE T UN NI NG / T C
PRG FW D
PRG FW D
PRG S TOP /R E SET
SHI FT
WARNING
Re ad the oper atio n man ua l be fore adjust o r insp ect.
Hig h Volt age ins ide. M aint ained b y t he w ell- traine d
WARNING WARNING pe rs onnel.
Co nfirm the inp ut and ou tp ut dc co nt rol cab les a re
Re ad the oper atio n man ua l be fore adjust o r insp ect. Re ad the oper atio n man ua l be fore adjust o r insp ect. we ll con ne cted.
Hig h Volt age ins ide. M aint ained b y t he w ell- traine d Hig h Volt age ins ide. M aint ained b y t he w ell- traine d Adju st o r inspe ct the inn er circ uits after pow er do wn
pe rs onnel. pe rs onnel. an d disch arge.
d W
H H
d
d
POWTRAN
RUN Hz
%
A °C
s
FWD V
RE V D IG ITAL O PERATO R
LO
CAL REMOTE TU
NN ING /T C
RUN Hz
%
A
s°C
FWD V
REV
PRG FWD
PRG FWD
PRG SHIFT
STOP/RESET
WARNING
Re ad the opera tion m an ual bef ore adj ust or insp ect .
Hig h Volta ge insid e. Mainta in ed by the well- traine d
pe rsonn el.
Co nfirm t he i nput a nd out put dc con trol cab les are
we ll con nec ted.
Adju st o r inspe ct the in ne r circuit s af ter po wer dow n
an d di sch arg e.
d
W WARNING
R ead the ope ration manu al be fore adjust or inspect .
H igh Volt age i nside. Main taine d by t he well-tra ined
d H pe rsonn el.
C onfi rm the in put an d out put dc con trol cab les ar e
w ell con nec ted .
PO WTR AN
R
DIGI TALOPERATOR
UN
L OCAL REMOT E TUNN ING / C
T
Hz
A %
d
s°C
F WD V
R EV
PRG FW D
WARNING
Read the operation manual before adjus t or inspect.
High Voltage inside. Maintained by the well-t rained
personnel.
Conf irm the input and out put dc c ontrol cables are
well connected.
Adjust or inspect the inner circuits af ter power down
and discharge.
W
23 www.fokusdrivesteknindo.co.id
SPECIFICATION and SIZE
W H
PO WTRAN
DI GIT AL OPERATOR
LO CAL R EMOTE T UNNIN G / TC
R UN Hz
%
A
s°C
F WD
R EV
V
PRG FW D
WARNING
Read the operation manual before adjust or inspect.
High Voltage ins ide. Maintained by the well-trained
personnel.
Conf irm the input and out put dc cont rol cables are
well connected.
Adjust or inspect the inner c ircuits after power down
and discharge.
b
d
24 www.fokusdrivesteknindo.co.id
Control System Display
25 www.fokusdrivesteknindo.co.id
www.fokusdrivesteknindo.co.id 26
Protection
Environment Running
Function