Sie sind auf Seite 1von 4

CURRICULUM VITAE

PersonalData
Data
Personal
Name : Giri Woryanto
Place,Date of Birth : Yukum Jaya, 29 November 1989
Home Address : Jl. Pattimura 114 RT 40/RW15, Yukum Jaya, Terbanggi
Besar, Lampung Tengah
Gender : Male
Email : giriworyanto@gmail.com
Phone Number : 085379112915

Education
Education

 SDN 3 Yukum Jaya (1996 – 2002)

 SMPN 3 Terbanggi Besar (2002 – 2005)

 SMAN 1 Terbanggi Besar (2005 – 2008)

 Electrical Engineering - University of Lampung (2008 – 2014)


Graduated March 2014, GPA 3.01 from 4.00

Organization
Organization
 Member Scout Period 1996-2002
 Member PMR SMPN 1 Terbanggi Besar Period 2002-2005
 Member football team SMAN 1 Terbanggi Besar Period 2005-2008
 Member Dept. APK Himatro University of Lampung Period 2009-2010
 Member Dept. DikDer Himatro University of Lampung Period 2010-2011
 Member external service BEM Faculty of Engineering University of Lampung
Period 2011-2012
Kemampuan
Kemampuan
 Programming mikrokontroler
 Instalation of home power grid
 Instalation of solar cell power grid
 Computer skills (MS Word, MS Excel, MS PowerPoint, MS Visio dan Internet)

WorkExperience
Experience
Work

 Practical work in Krakatau Daya Listrik ( September 2011 – Oktober 2011 )


 Practical work in PLTA Batu Tegi ( September 2012 - Oktober 2012 )
Job details :
1. Maintenance carbon brush exiter
2. Maintenance battery
3. Maintenance silica gel transformator

 Assistant of High Voltage Engineering Laboratory of Lampung University


Job details :
1. Providing practice materials "DC High Voltage Generation"

 Technician Instrument & Control at Lampung 2 X 100 MW Power Plant Project,


PT. Adhi Karya Persero. Tbk (June 23, 2014 - December 23, 2014)
Job details :
1. Repair and calibration MOV (Motor operated valve)
The MOV used is divided into two type: analog mov and digital mov.
Anal mov uses 4-20 mA principle for command and feedback to dcs,
whereas digital mov uses the principle of switch contact and 24 VDC for
command and feedback to dcs. Analog moves are widely used to control
air and water requirements in the boiler, control the speed of the fan.
Digital Mov is widely used for control of damper operation, main steam
valve, emergency valve steam. The calibration step of each type of mov is
different depending on the type. There is a type of mov that only uses a
limit switch in its operation control, this is in a digital mov. Anal moves
always use modules for control of operation.

2. Repair and temperature sensor calibration


Temperature sensors used there are some types: thermocouple type K, E,
and RTD. The result of the sensor readings is changed using a converter
into a 4-20 mA signal to be read by dcs.
Calibrate the sensor by using temperature calibrator by inputting the
temperature according to the range of whether it has a good response or
not. To measure the temperature of the sensor directly used the tool
commonly called the injector. Injector can also be used to test the cable
from sensor to dcs, by inject signal 4-20 mA.

3. Repair pressure gauge and temperature gauge


Improvements to common gauges are made when a connection leaks.
Replacement is done if the appointment is not suitable. Pressure gauge is
used to indicate wind pressure, oil, and water. Temperature gauge for
indication of temperature of oil, water, steam.

4. Repair and calibration of transmitter


The transmitter calibration uses two tools, namely hand pump and hart
com. Hand pump is used to provide the lowest and highest pressure of the
transmitter. Hart com is used to define the lower limits and limits on
readability of the transmitter.
SPV Instrument & Control at PLTU Lampung 2 X 100 MW, PT. Adhi Karya
Persero. Tbk (December 23, 2014 - June 30, 2017)
Job details :
1. Repair and calibration of coalfeeder
One coalfeeder consists of mov, coalfeeder motor belt, no coal sensor, belt
tracking sensor, loadcell, variable speed, and control panel. Calibration of
coal feeder starts with running motor belt using maximum speed, then
adjust zero and adjust span. To get the value of span used ballast in the
form of a roller placed above the belt, the value of the span sought for 40 t
/ h.

2. Calibration belt scale conveyor


The calibration step is similar to the calibration of coalfeeder because it
uses the same module "Yamato CFC 201". The desired span value on the
belt scale is 288 t / h according to the calculation based on the belt length,
velocity, and weight per meter of weights.

Research
Research

 Guidance Setup Process (Guide Vanes) To Maintain Stability Of The Speed Of


Turbine Generator Round In Batutegi Hydro Power Plant Unit.
 Design Build Dual Battery Charge Controller Source of Load Supply with PLTS
and PLN Based on Microcontroller (Case Study of Fingerprint at Dean of
Faculty of Engineering, Lampung University)