Fixit Pidicrete CF 151M3(S)


High Range Water reducing Cum retarding admixture

Dr. Fixit Pidicrete CF 151M3(S) is a superplasticising DOSAGE:


admixture design with specially formulated polymers to Dosage range of Dr. Fixit Pidicrete CF 151M3(S)
produce homogeneous concrete, free from bleeding will be 200 ml to 600 ml per bag of cement.
and segregation. • Optimum dosage should be determined by
It also imparts the cohesiveness to concrete mix for doing site trial mixes. Dosage may go above

CONCRETE ADMIXTURES
easy pouring with better suface finish. maximum limit for High Performance Concrete
and shall be determined by site trial mix.
SPECIFICATION : IS: 9103-1999 and ASTM-C-494-
86, Type G COMPATIBILITY:
Dr. Fixit Pidicrete CF 151M3(S) is compatible with
AREA OF APPLICATION: all types of cement e.g. OPC, PPC, PSC etc.
Pumpable Concrete Dr. Fixit Pidicrete CF 151M3(S) is
Pavement Quality Concrete compatible with all air entraining agent
which complies
Ready mix concrete
wiith IS 9103-2003 and Integral water proofing
compound which complies with IS 2645- 1978.
FEATURES & BENEFITS: If other admixtures are to be used in concrete
Water reduction upto 12-15 % without effecting containing Dr. Fixit Pidicrete CF 151M3(S) they
the workability. must be dispensed separately.
Helps in reducing cement content for a required
strength by reducing w/c ratio. SAFETY PRECAUTIONS :
Dr. Fixit Pidicrete CF 151M3(S) is a non-toxic
and inflammable. When in contact with the skin,
Increases workability at a given w/c ratio, resulting
it should be washed with cold water.
easy placing, and eliminates honeycombing.
High workability for longer periods to allow long
distance transport of concrete. TECHNICAL INFORMATION :
Reduction in shrinkage cracks Appearance : Dark Brown Liquid
Sp.Gravity : 1.15 +/- 0.02
Less permeable and hence more durable concrete.
Chloride content : Nil
pH Value : 7 +/- 1
METHOD OF APPLICATION:
Concrete shall be mixed with 50-70% of the STORAGE :
PIDICRETE CF 330
mixing water(based on mix design by weight).
• Keep the liquid above freezing temperature.
The correct quantity of Dr. Fixit Pidicrete CF
• If the product has frozen, thaw it at room
151 should be measured with recommended
temperature(25°C) and agitate to completely
dispenser and should be added to the concrete with
reconstitute it in the original form.
remaining 30% mixing water and allow to mix it for
recommended mixing time. • Store under cover ; protect from direct sunlight.
Dr. Fixit Pidicrete CF 151M3(S) should not be • Failure to comply with recommended storage
added in dry mixes under any circumstances condition may result in premature deterioration of
the product and packaging.

PACKING: 250 & 265 kg,


Tanker supply in litres / kgs
Pidilite Industries Limited
Construction Chemicals Division materials used and on-site workmanship are factors beyond our control, there are no
expressed or implied guarantee / warranty as to the results obtained. The Company
Ramkrishna Mandir Road Post Box No. 17411 does not assume any liability or any consequential damage for unsatisfactory
Andheri (E) Mumbai 400059 INDIA results, arising from the use of our products.
Tel +91-22-2835 7000 Fax +91-22-2835 7008
website www.doctor-fixit.com E-mail drfixit@pidilite.com
Disclaimer: The product information & application details given by the company
& its agents has been provided in good faith & meant to serve only as a general
guideline during usage. Users are advised to carry out tests & take trials to ensure
on the suitability of products meeting their requirement prior to full scale usage of
our products. Since the correct identification of the problems, quality of other

Das könnte Ihnen auch gefallen