Live Load (refer to Chapter II table 205-1) NSCP 2010
= 2.4 kpa (maintenance access)
Dead Load (refer to Chapter II table 204-1 and 204-2) NSCP 2010
= 24 kn/cum (concrete)
= kn/sqm (ceiling)
= kn/sqm (flr finish)
Lb= 4.45 m
D) Check ACI limits (if all the limits does not okay, try again later)
a) LL/DL < 3 = 1<3 ok!
b) (l-s)/s < 0.2 = 0 < 0.2 ok!
c) loads are uniformly dist ok!
other Soln:
Mu= 2.122 knm (max or highest)
Ru=Mu/øbd²
Ru= 0.431 mpa
P=
P= 0.0015746
Pmin=1.4/fy 276
Pmin= 0.005072464
Pmax=0.75[0.85fc'B600)/(fy(600+fy))
B=0.85-(0.05/7)*(fc'-30)
B= 0.87
Pmax= 0.037863258
Pmax > P < Pmin
therefore use Pmin P= 0.005072464
P= 0.0013478
Pmin=1.4/fy
Pmin= 0.005072464
Pmax=0.75[0.85fc'B600)/(fy(600+fy))
B=0.85-(0.05/7)*(fc'-30)
B= 0.87
Pmax= 0.037863258
Pmax > P < Pmin
therefore use Pmin P= 0.005072464
Ast=0.0018bh
Ast= 180 mm²
Reqd spacing (S) = 1000(Ab)/As
Ab=π/4*(øbar)²
Ab= 78.5 mm²
S= 436.1 mm say 400 mm