Witnessed Burst Test for the below mentioned cylinders with Achieved Result :-
Burst Standard
Cylinder
Pressure
Capacity Serial No.
Achieved
(Liter)
(Bar)
48 L 48277 87.12 OS : 120
48 L 48666 84.62 OS : 120
48 L 49090 86.12 OS : 120
48 L 52225 84.12 GSO ISO 22991
48 L 52825 86.12 GSO ISO 22991
48 L 53323 85.12 GSO ISO 22991
48 L 53838 87.62 GSO ISO 22991
Burst test pressure value for above all meets the standard requirements - Found accepted.
Verified & Reviewed calibration certificate of pressure gauge – Found valid.