Sie sind auf Seite 1von 1

COLUMN SCHEDULE fy = 414 MPa (60,000 psi)

FOUNDATION TO 7TH FLOOR...................................f'c = 55 MPa (8,000 psi)


8TH TO 13TH FLOOR..................................................f'c = 55 MPa (8,000 psi)
14TH TO ROOF DECK FLOOR...................................f'c = 41 MPa (6,000 psi)

C - 1A C - 2A C - 3A C - 4A C - 5A C - 6A C - 7A C - 8A
7TH TO 8TH TO
9TH FLOOR

SIZE = 500mm x 1400mm SIZE = 500mm x 1100mm SIZE = 500mm x 1150mm SIZE = 700mm x 700mm SIZE = 200mm x 500mm
VERT. BARS = 34 - 28mmØ VERT. BARS = 30 - 28mmØ VERT. BARS = 26 - 28mmØ VERT. BARS = 32 - 25mmØ VERT. BARS = 8 - 20mmØ
TIES = 6 - 10mmØ PER SET TIES = 6 - 10mmØ PER SET TIES = 5 - 10mmØ PER SET TIES = 7 - 10mmØ PER SET TIES = 2 - 10mmØ PER SET
5TH TO 6TH TO
7TH FLOOR

SIZE = 550mm x 1550mm SIZE = 500mm x 1200mm SIZE = 500mm x 1150mm SIZE = 800mm x 800mm SIZE = 200mm x 500mm
VERT. BARS = 40 - 28mmØ VERT. BARS = 32 - 28mmØ VERT. BARS = 28 - 28mmØ VERT. BARS = 36 - 25mmØ VERT. BARS = 8 - 20mmØ
TIES = 6 - 10mmØ PER SET TIES = 5 - 10mmØ PER SET TIES = 5 - 10mmØ PER SET TIES = 7 - 10mmØ PER SET TIES = 2 - 10mmØ PER SET
3RD TO 4TH TO
5TH FLOOR

SIZE = 550mm x 1600mm SIZE = 500mm x 1300mm SIZE = 500mm x 1150mm SIZE = 800mm x 800mm SIZE = 200mm x 500mm
VERT. BARS = 48 - 28mmØ VERT. BARS = 36 - 28mmØ VERT. BARS = 30 - 28mmØ VERT. BARS = 40 - 25mmØ VERT. BARS = 8 - 20mmØ
TIES = 7 - 10mmØ PER SET TIES = 6 - 10mmØ PER SET TIES = 5 - 10mmØ PER SET TIES = 7 - 10mmØ PER SET TIES = 2 - 10mmØ PER SET
FOUNDATION TO 2ND FLOOR

HANGER COLUMN
STAIR STIFFENER
COLUMN
TO 3RD FLOOR

500mm
NOTES:
1.) ALL COLUMN TIES PER SET SHOULD BE SPACED 350mm
6 @ 75mm, 6 @ 100mm REST @ 150mm O.C.
(UNLESS SPECIFIED OTHERWISE).
2.) NO PIPES SHALL BE EMBEDDED INSIDE ANY COLUMN. 350mm x 500mm
SIZE = 650mm x 1700mm SIZE = 600mm x 1400mm SIZE = 550mm x 1200mm SIZE = 800mm x 800mm 3.) ALL PLANTED COLUMNS MUST BE SUPPORTED BY BEAMS OR GIRDERS. SIZE = 200mm x 500mm SIZE = 8 - 25mmØ
VERT. BARS = 62 - 28mmØ VERT. BARS = 48 - 28mmØ VERT. BARS = 36 - 28mmØ VERT. BARS = 40 - 25mmØ VERT. BARS = 8 - 20mmØ VERT. BARS = 2 - 10mmØ PER SET
TIES = 8 - 10mmØ PER SET TIES = 6 - 10mmØ PER SET TIES = 5 - 10mmØ PER SET TIES = 7 - 10mmØ PER SET TIES = 2 - 10mmØ PER SET TIES =

GENERAL CONTRACTOR:
16-STOREY OFFICE BUILDING
ASEC DEVELOPMENT AND
23
CONSTRUCTION CORPORATION
GENERAL BUILDING CONTRACTOR ENRISON HOLDINGS INC. AS - BUILT PLAN S
Tower A-3rd Floor, Regalia Park, 150 P. Tuazon
Avenue, Cubao, Quezon City 1109
30