Sie sind auf Seite 1von 20

product

handbook

Energy in all we do
Gas Turbine Generator PackageS
Product overview
1 to 22 MW
Including (standard supply)
• Gas turbine, Reduction Gear Box, Generator • Enclosure
• Starting equipment • Air filtration system
• Gas fuel system • Integrated control system
• Lubrication system • Fire detection and extinguishing equipment
• Turbine compressor cleaning system • Electrical cables
• Base frame • Erection, commissioning and tests
• Spring dampers

w l

2
product rANGE

Systems Available3)
ISO1) Output Power

Exhaust gas Temp.


Exhaust gas Flow
ISO1) Heat rate

Comtustion
Efficiency
Fuel Input

Electrical
version

Fuels2)
TurbineType
MW kJ/kWh MJ/s % kg/s °C
Saturn 20 T-1601 1.20 14’810 5.0 24.3 6.5 506 ng/lf/lPg/lbtu S, WI
Centaur 40 T-4700 3.51 12’900 12.6 27.9 19.0 443 ng/lf/lPg/lbtu S, DLE, WI
Centaur 50 T-6201 4.60 12’266 15.7 29.3 19.1 509 ng/lf/lPg/lbtu S, DLE, WI
Mercury 50 T-6401 4.60 9’350 12.0 38.5 17.8 374 ng/lbtu DLE
Taurus 60 T-7901 5.67 11’427 18.0 31.5 21.8 510 ng/lf/lPg/lbtu S, DLE, WI
Taurus 65 T-8401 6.30 10’945 19.2 32.9 21.1 549 ng DLE
Taurus 70 T-10801 7.96 10’503 23.2 34.3 26.9 508 ng/lf/lPg/lbtu S, DLE
Mars 90 T-13002 9.87 10’827 29.7 33.2 40.2 465 ng/lf/lPg/lbtu S, DLE, WI
Mars 100 T-16002 11.35 10’934 34.5 32.9 42.6 484 ng/lf/lPg/lbtu S, DLE, WI
Titan 130 T-20501 15.00 10’227 42.6 35.2 49.8 496 ng/lf/lPg/lbtu S, DLE
Titan 250 T-30002 21.75 9’256 55.9 38.9 68.2 463 ng DLE
1) ISO conditions: Sea level, 15°C, no gas path losses
2) NG = natural gas; LF = liquid fuel; LPG = liquified propane gas; LBTU = low BTU gas
3) S = standard combustion system; WI = water injection; DLE = SoLoNOx

Steam Production4) @

Steam Production4) @

Steam Production @
Additional fuel input

Additional fuel input


10 bar(a) saturated,

10 bar(a) saturated,

Chilling Capacity6)
10 bar(a) saturated

4)

to reach 1100°C
fired to 1100°C
to reach 800°C
fired to 800°C
Generator

5)
Voltage

Weight
TurbineType L W H5)
kV t/h t/h MJ/s t/h MJ/s MJ/s - m /h 3
m m m t
Saturn 20 0.4 3.9 7.6 2.4 11.6 5 3’728 - 641 6.0 1.8 7.6 14
Centaur 40 6.3, 11 8.9 21.5 8.3 33.8 16 8’933 - 1’563 10.0 2.2 6.6 40
Centaur 50 6.3, 11 11.5 22.2 6.8 34.4 15 10’878 - 1’871 10.0 2.2 6.6 45
Mercury 50 6.3, 11 5.9 19.8 9.3 31.3 17 3’744 - 6447) 13.7 2.9 6.7 52
Taurus 60 6.3, 11 13.2 25.3 7.8 38.9 17 12’412 - 2’134 10.0 2.2 6.6 45
Taurus 65 6.3, 11 14.5 24.5 6.5 38.0 15 13’436 - 2’311 11.0 2.2 6.6 56
Taurus 70 6.3, 11 16.2 30.9 9.7 48.5 21 15’328 - 2’636 12.6 2.9 9.4 68
Mars 90 6.3, 11 20.7 47.0 16.5 72.0 33 20’648 - 3’551 14.9 2.9 9.7 84
Mars 100 6.3, 11 24.0 50.1 16.6 76.7 34 23’404 - 4’025 14.9 2.9 9.7 85
Titan 130 6.3, 11 29.8 59.0 18.7 89.6 39 28’391 - 4’882 15.6 2.9 10.0 90
Titan 250 11 36.2 80.5 28.3 122.9 56 34’820 - 5’988 18.2 3.4 14.0 99
4) Site Conditions for Steam production:
Sea level, 15°C, 75 mmH2O inlet loss, 250 mmH2O exhaust loss
Natural gas fuel; Full load; Feed water temperature: 105°C, 100% condensate return, no deaerator, no blowdown
5) H & Weight = including Filter system and for outdoor installation
6) Chilling capacity is calculated based on two stages Exhaust Chiller with Exhaust Temperature in/out aprox. 500/170°C,
chilled water outlet/inlet temperature 7/12°C. Condensation temperature 26°C maximum.
7) Single stage Exhaust Chiller

All specifications are for reference only, subject to change without notice.

3
Gas Turbine Generator Package

SATURN 20
Turbine type: SATURN 20 (T 1601)
Main data (ISO, no losses)

Electrical power: MW 1.20


Heat rate: kJ/kWE-hr 14’810
Fuel input: MJ/s 4.95
Efficiency: % 24.32
Exhaust gas flow: kg/s 6.54
Exhaust gas temp. °C 506
Fuel: NG/LF/LPG/LBTU
Start system: AC
Gen. Voltage: kV 0.4
Comb. Syst. Avail.: * S/WI

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves

1,220 15,700 7.20 552


kWe
7.10 538
1,200 15,600
7.00 EGF EGT 524
1,180 15,500
6.90 510
HR

Exh. Gas Temperature (°C)


1,160 15,400
Gen. Output Power (kWe)

6.80 496
Heat Rate (kJ/kWh)

Exh. Gas Flow (kg/s)

1,140 15,300 6.70 482

6.60 468
1,120 15,200
6.50 454
1,100 15,100 6.40 440

1,080 15,000 6.30 426

6.20 412
1,060 14,900
6.10 398
1,040 14,800
6.00 384
1,020 14,700 5.90 370
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

4
Gas Turbine Generator Package

CENTAUR 40
Turbine type: CENTAUR 40 (T 4700)
Main data (ISO, no losses)

Electrical power: MW 3.51


Heat rate: kJ/kWE-hr 12’900
Fuel input: MJ/s 12.59
Efficiency: % 27.90
Exhaust gas flow: kg/s 18.99
Exhaust gas temp. °C 443
Fuel: NG/LF/LPG/LBTU
Start system: AC
Gen. Voltage: kV 6.3 or 11
Comb. Syst. Avail.: * S/WI/DLE

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves
4,400 13,900 21.50 460
4,300 13,800 21.20 458
4,200 kWe 13,700 20.90 456
HR EGF
EGT
4,100 13,600 20.60 454
4,000 13,500 20.30 452

Exh. Gas Temperature (°C)


Gen. Output Power (kWe)

3,900 13,400 20.00 450


Heat Rate (kJ/kWh)

Exh. Gas Flow (kg/s)

3,800 13,300 19.70 448


3,700 13,200 19.40 446
3,600 13,100 19.10 444
3,500 13,000 18.80 442
3,400 12,900 18.50 440
3,300 12,800 18.20 438
3,200 12,700 17.90 436
3,100 12,600 17.60 434
3,000 12,500 17.30 432
2,900 12,400 17.00 430
2,800 12,300 16.70 428
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

5
Gas Turbine Generator Package

Centaur 50
Turbine type: CENTAUR 50 (T 6201)
Main data (ISO, no losses)

Electrical power: MW 4.60


Heat rate: kJ/kWE-hr 12’266
Fuel input: MJ/s 15.68
Efficiency: % 29.34
Exhaust gas flow: kg/s 19.08
Exhaust gas temp. °C 509
Fuel: NG/LF/LPG/LBTU
Start system: AC
Gen. Voltage: kV 6.3 or 11
Comb. Syst. Avail.: * S/WI/DLE

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves
5,650 13,200 21.50 530

5,500 13,100 21.20 528


HR 20.90 EGF 526
5,350 13,000
20.60 EGT 524
kWe
5,200 12,900
20.30 522

Exh. Gas Temperature (°C)


Gen. Output Power (kWe)

5,050 12,800 20.00 520


Heat Rate (kJ/kWh)
Exh. Gas Flow (kg/s)

4,900 12,700 19.70 518


19.40 516
4,750 12,600
19.10 514
4,600 12,500
18.80 512
4,450 12,400 18.50 510
4,300 12,300 18.20 508
17.90 506
4,150 12,200
17.60 504
4,000 12,100
17.30 502
3,850 12,000 17.00 500
3,700 11,900 16.70 498
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

6
Gas Turbine Generator Package

mercury 50
Turbine type: MERCURY 50 (T 6401)
Main data (ISO, no losses)

Electrical power: MW 4.60


Heat rate: kJ/kWE-hr 9’350
Fuel input: MJ/s 11.95
Efficiency: % 38.49
Exhaust gas flow: kg/s 17.82
Exhaust gas temp. °C 374
Fuel: NG/LBTU
Start system: AC
Gen. Voltage: kV 6.3 or 11
Comb. Syst. Avail.: * DLE

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves
5,500 10,215 19.75 398
5,400 10,130 19.50 394
5,300 kWe 10,045 19.25 390
HR EGF EGT
5,200 9,960
19.00 386
5,100 9,875
18.75 382
5,000 9,790
18.50 378

Exh. Gas Temperature (°C)


Gen. Output Power (kWe)

4,900 9,705
Exh. Gas Flow (kg/s)
Heat Rate (kJ/kWh)

4,800 9,620 18.25 374


4,700 9,535 18.00 370
4,600 9,450 17.75 366
4,500 9,365 17.50 362
4,400 9,280 17.25 358
4,300 9,195 17.00 354
4,200 9,110
16.75 350
4,100 9,025
16.50 346
4,000 8,940
3,900 8,855 16.25 342
3,800 8,770 16.00 338
3,700 8,685 15.75 334
3,600 8,600 15.50 330
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

7
Gas Turbine Generator Package

TAURUS 60
Turbine type: TAURUS 60 (T 7901)
Main data (ISO, no losses)

Electrical power: MW 5.67


Heat rate: kJ/kWE-hr 11’427
Fuel input: MJ/s 18.00
Efficiency: % 31.50
Exhaust gas flow: kg/s 21.77
Exhaust gas temp. °C 510
Fuel: NG/LF/LPG/LBTU
Start system: AC
Gen. Voltage: kV 6.3 or 11
Comb. Syst. Avail.: * S/WI/DLE

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves
7,100 12,300 23.80 537
23.60 535
6,900 12,200 23.40 533
23.20 EGF 531
6,700 12,100 EGT
HR 23.00 529
6,500 kWe 12,000 22.80 527
22.60 525

Exh. Gas Temperature (°C)


Gen. Output Power (kWe)

6,300 11,900 22.40 523


Exh. Gas Flow (kg/s)
Heat Rate (kJ/kWh)

22.20 521
6,100 11,800
22.00 519
5,900 11,700 21.80 517
21.60 515
5,700 11,600 21.40 513
21.20 511
5,500 11,500
21.00 509
5,300 11,400 20.80 507
20.60 505
5,100 11,300 20.40 503
20.20 501
4,900 11,200 20.00 499
4,700 11,100 19.80 497
19.60 495
4,500 11,000 19.40 493
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

8
Gas Turbine Generator Package

TAURUS 65
Turbine type: TAURUS 65 (T 8401)
Main data (ISO, no losses)

Electrical power: MW 6.30


Heat rate: kJ/kWE-hr 10’945
Fuel input: MJ/s 19.16
Efficiency: % 32.88
Exhaust gas flow: kg/s 21.10
Exhaust gas temp. °C 549
Fuel: NG
Start system: AC
Gen. Voltage: kV 6.3 or 11
Comb. Syst. Avail.: * DLE

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves
8,100 12,000 24.00 580
7,900 11,900
23.50 575
7,700 11,800
EGF EGT
7,500 11,700 23.00 570
kWe HR
7,300 11,600
22.50 565
7,100 11,500

Exh. Gas Temperature (°C)


Gen. Output Power (kWe)

Exh. Gas Flow (kg/s)


Heat Rate (kJ/kWh)

6,900 11,400 22.00 560


6,700 11,300
6,500 11,200 21.50 555

6,300 11,100 21.00 550


6,100 11,000
5,900 10,900 20.50 545
5,700 10,800
20.00 540
5,500 10,700
5,300 10,600 19.50 535
5,100 10,500
19.00 530
4,900 10,400
4,700 10,300 18.50 525
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

9
Gas Turbine Generator Package

TAURUS 70
Turbine type: TAURUS 70 (T 10801)
Main data (ISO, no losses)

Electrical power: MW 7.96


Heat rate: kJ/kWE-hr 10’503
Fuel input: MJ/s 23.24
Efficiency: % 34.27
Exhaust gas flow: kg/s 26.88
Exhaust gas temp. °C 508
Fuel: NG/LF/LPG/LBTU
Start system: DC
Gen. Voltage: kV 6.3 or 11
Comb. Syst. Avail.: * S/DLE

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves
9,500 11,550 30.00 537

9,250 11,450 29.50 534

9,000 kWe 11,350 29.00 531


EGF
EGT
HR 28.50 528
8,750 11,250
28.00 525

Exh. Gas Temperature (°C)


Gen. Output Power (kWe)

8,500 11,150
Exh. Gas Flow (kg/s)
Heat Rate (kJ/kWh)

27.50 522
8,250 11,050
27.00 519
8,000 10,950
26.50 516
7,750 10,850
26.00 513
7,500 10,750
25.50 510
7,250 10,650
25.00 507
7,000 10,550 24.50 504
6,750 10,450 24.00 501
6,500 10,350 23.50 498
6,250 10,250 23.00 495
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

10
Gas Turbine Generator Package

MARS 90
Turbine type: MARS 90 (T 13002)
Main data (ISO, no losses)

Electrical power: MW 9.87


Heat rate: kJ/kWE-hr 10’827
Fuel input: MJ/s 29.69
Efficiency: % 33.24
Exhaust gas flow: kg/s 40.16
Exhaust gas temp. °C 465
Fuel: NG/LF/LPG/LBTU
Start system: AC
Gen. Voltage: kV 6.3 or 11
Comb. Syst. Avail.: * S/WI/DLE

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves
11,000 12,380 45.50 495
10,800 12,310
44.50 490
10,600 12,240
10,400 kWe 12,170 EGF EGT
43.50 485
HR
10,200 12,100
10,000 12,030 42.50 480

Exh. Gas Temperature (°C)


Gen. Output Power (kWe)

9,800 11,960 41.50 475


Exh. Gas Flow (kg/s)
Heat Rate (kJ/kWh)

9,600 11,890
9,400 11,820 40.50 470
9,200 11,750
39.50 465
9,000 11,680
8,800 11,610 38.50 460
8,600 11,540
8,400 11,470 37.50 455
8,200 11,400 36.50 450
8,000 11,330
7,800 11,260 35.50 445
7,600 11,190
34.50 440
7,400 11,120
7,200 11,050 33.50 435
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

11
Gas Turbine Generator Package

MARS 100
Turbine type: MARS 100 (T 16002)
Main data (ISO, no losses)

Electrical power: MW 11.35


Heat rate: kJ/kWE-hr 10’934
Fuel input: MJ/s 34.47
Efficiency: % 32.92
Exhaust gas flow: kg/s 42.57
Exhaust gas temp. °C 484
Fuel: NG/LF/LPG/LBTU
Start system: AC
Gen. Voltage: kV 6.3 or 11
Comb. Syst. Avail.: * S/WI/DLE

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves
13,250 11,600 48.00 510
13,000 11,550
47.00 505
12,750 11,500
12,500 11,450 46.00 EGT 500
kWe HR EGF
12,250 11,400
45.00 495
12,000 11,350

Exh. Gas Temperature (°C)


Gen. Output Power (kWe)

Exh. Gas Flow (kg/s)

11,750 11,300
Heat Rate (kJ/kWh)

44.00 490
11,500 11,250
11,250 11,200 43.00 485

11,000 11,150 42.00 480


10,750 11,100
10,500 11,050 41.00 475
10,250 11,000
40.00 470
10,000 10,950
9,750 10,900 39.00 465
9,500 10,850
38.00 460
9,250 10,800
9,000 10,750 37.00 455
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

12
Gas Turbine Generator Package

TITAN 130
Turbine type: TITAN 130 (T 20501)
Main data (ISO, no losses)

Electrical power: MW 15.00


Heat rate: kJ/kWE-hr 10’227
Fuel input: MJ/s 42.62
Efficiency: % 35.19
Exhaust gas flow: kg/s 49.79
Exhaust gas temp. °C 496
Fuel: NG/LF/LPG/LBTU
Start system: DC
Gen. Voltage: kV 6.3 or 11
Comb. Syst. Avail.: * S/DLE

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves
17,000 11,300 55.00 530

16,600 11,200 54.00 525


16,200 11,100 EGF
kWe 53.00 520
HR
15,800 11,000 EGT
52.00 515

Exh. Gas Temperature (°C)


Gen. Output Power (kWe)

15,400 10,900
Exh. Gas Flow (kg/s)
Heat Rate (kJ/kWh)

51.00 510
15,000 10,800

14,600 10,700 50.00 505

14,200 10,600 49.00 500


13,800 10,500
48.00 495
13,400 10,400
47.00 490
13,000 10,300
46.00 485
12,600 10,200

12,200 10,100 45.00 480

11,800 10,000 44.00 475


-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

13
Gas Turbine Generator Package

TITAN 250
Turbine type: TITAN 250 (T 30002)
Main data (ISO, no losses)

Electrical power: MW 21.75


Heat rate: kJ/kWE-hr 9’256
Fuel input: MJ/s 55.92
Efficiency: % 38.89
Exhaust gas flow: kg/s 68.21
Exhaust gas temp. °C 463
Fuel: NG
Start system: AC
Gen. Voltage: kV 11
Comb. Syst. Avail.: * DLE

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves
25,500 9,950 76.00 495
25,000 9,900 75.00 492
24,500 9,850 74.00 489
kWe EGF EGT
24,000 9,800 73.00 486
HR 72.00 483
23,500 9,750
23,000 9,700 71.00 480

Exh. Gas Temperature (°C)


Gen. Output Power (kWe)

70.00 477
Exh. Gas Flow (kg/s)
Heat Rate (kJ/kWh)

22,500 9,650
69.00 474
22,000 9,600
68.00 471
21,500 9,550
67.00 468
21,000 9,500
66.00 465
20,500 9,450
65.00 462
20,000 9,400
64.00 459
19,500 9,350 63.00 456
19,000 9,300 62.00 453
18,500 9,250 61.00 450
18,000 9,200 60.00 447
17,500 9,150 59.00 444
17,000 9,100 58.00 441
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

14
CUSTOMER SERVICES
• MAINTENANCE • EQUIPMENT OVERHAUL
• LONG-TERM SERVICE AGREEMENTS • GAS TURBINE EXCHANGE PROGRAM
• Remote diagnostics • GAS TURBINE FIELD REPAIR
with InSight System • UPGRADES, RETROFITS AND PLANT
• SUPPLY OF CERTIFIED SERVICE PARTS MODIFICATIONS

These services can be provided in the frame of maintenance agreements, individually tailored to meet
your requirements. Contracts are generally grouped under the following contractual models:

PMC: Preventive Maintenance Contract


BUOA: Beneficial Use Overhaul Agreement
EMC: Extended Maintenance Contract
FMC: Full Maintenance Contract (or Long Term Service Agreement)
O&M: Operation and Maintenance

PMC BUOA EMC FMC O&M

Operation or Operation Supervision

Service parts

Troubleshooting & Repair on Package or Plant

Turbine unscheduled OH and Repair

Turbine scheduled OH or Pro Rata Warranty

Annual boroscope Inspection of GT & RGB

Annual maintenance on Package or Plant

15
WATT’S
INSIDE OUR PACKAGE

1 . ENCLOSURE 7 . AIR FILTER SYSTEM FOR GENERATOR


The enclosure protects the package from COOLING AND VENTILATION AIR
weather, and reduces operational noise,
allowing an outdoor installation. This 8 . GAS TURBINE
eliminates the need for a building and Solar industrial gas turbines combine
saves investment cost. Modular panels ease of maintenance with highest reliabil-
allow the entire enclosure to be disas- ity, durability and efficiency. This guaran-
sembled in sections. tees you the best payback throughout the
lifetime of the plant.
2 . ENCLOSURE DOORS
Doors allow full access to every side 9 . REDUCTION GEAR
of the package making inspection and Matches gas turbine rotational speed to
maintenance operations fast, safe and speed of generator rotor. 2
easy.
10 . GENERATOR
3 . BASE FRAME Transforms mechanical energy into
The base frame integrates all subsys- electrical power.
tem components with gas turbine and
generator and allows an easy and fast 11 . SUBSYSTEMS
single-lift installation or relocation Air, Fuel, Oil and Start Subsystems are
fully integrated and tested before ship-
4 . SPRING DAMPERS ment. This safes time and cost on site.
The spring dampers absorb operational
vibrations and minimise the require- 12 . STARTING SYSTEM
ments for the foundation, allowing an
installation practically anywhere. 13 . FUEL SYSTEM

5 . MAINTENANCE PROVISIONS 14 . LUBE-OIL SYSTEM CONTROL SYSTEM


The package is designed for ease of with integrated lube-oil cooler The advanced control system can ope-
maintenance, with built-in maintenance rate the package completely automati-
devices. Provisions to remove the genera- 15 . CONNECTIONS cally, and allows easy communication
tor and gas turbine are integrated in the The simple interfaces guarantee an easy with other systems. This provides
package design. This safes time and cost and fast installation and integration. This equipment safety, operator convenience
during maintenance. saves time and cost on site. and low operating cost.

6 . FILTER STRUCTURE FOR 16 . Interface Connections CONTROL ROOM


COMBUSTION AIR • fuel The control and electrical systems are
Can be configured to local conditions • instrument air housed in a tightly sealed and air-condi-
and allows for installation of inlet air • 400V auxiliary power tioned control room, which is integrated on
cooling. • medium voltage power the package. This eliminates the need for
• connection to compressor washing a separate control room and associated
system construction costs.

16
6

9
10 8
12

5
14

3
13
11

16
CABLING
The interconnecting cabling is installed 15
and tested before shipment. This guaran-
tees highest quality and reliability.
4
AUXILIARY POWER SWITCHGEAR Options Available
some of the available options are:
BATTERY SYSTEM • alternative fuel capability (gas, liquid, low BTU)
• water injection or SoLoNOx combustion
HUMAN MACHINE INTERFACE (HMI) system for lowest emissions is available
The user-friendly interface can be oper- for most turbines
ated locally or via the remote operator • packaging designed for a wide variety of
station. This guarantees environmental conditions
an optimum operation of your • combustion air inlet chilling
equipment. • generator voltages of 6.3 or 11 kV

17
TURBOMACH - PROVIDING INDUSTRIAL POWER GENERATION

about us
Turbomach is a leading provider of industrial gas tur-
bine-based cogeneration systems.
We are fully dedicated to our power generation mar-
kets, leveraging the experience with over 4500 power
generation units installed worldwide. Together with
Solar Turbines, Turbomach is part of a diverse multi-
talented team of more than 6000 employees with dec-
ades of experience working as a global team com-
mitted to the common goal of delivering complete
customer satisfaction.

18
CONTACTS
for FuRTHER information, or our nearest
please visit field office.
www.turbomach.com
or contact us at:

Turbomach
Switzerland Brazil Netherlands
Via Campagna 15 Sao Paulo 2171 AL Sassenheim
6595 Riazzino Tel: +55 11 2109 2015 or Tel: +31 71 408 09 19
Tel: +41 91 851 15 11 Tel: +34 93 586 41 62 contact_nl@turbomach.com
Fax: +41 91 851 15 55 contact_lam@turbomach.com
contact@turbomach.com Pakistan
Colombia 54000 Lahore
SOLAR TURBINES Cartagena de Indias Tel: +92 42 35 87 7760
USA Tel: +57 5 664 72 16 or contact_pk@turbomach.com
Solar Turbines Incorporated Tel: +34 93 586 41 62
San Diego, California contact_lam@turbomach.com Russia
Tel: +1 (619) 544 5352 114400 Moscow
powergen@solarturbines.com Egypt Tel: +7 495 755 81 53
Cairo contact_ru@turbomach.com
Tel: +20 10 00 36 76 76
contact_africa@turbomach.com Singapore
Singapore 627973
France Tel: +65 6828 7000
91280 St-Pierre-Du-Perray contact_asia@turbomach.com
Tel: +33 1 6989 00 00
contact_fr@turbomach.com Spain
08290 Cerdanyola - Barcelona
Germany Tel: +34 93 586 41 62
64347 Griesheim contact_es@turbomach.com
Tel: +49 6155 8749-0
kontakt_de@turbomach.com Thailand
Bangkok 10250
India Tel: +66 2 366 0712-5
Mumbai 400 076 contact_asia@turbomach.com
Tel: +91 22 4042 54 25
contact_in@turbomach.com Turkey
34330 Istanbul
Italy Tel: +90 212 284 6001
43122 Parma contact_tr@turbomach.com
Tel: +39 0521 275 811
contact_it@turbomach.com United Arab Emirates
Dubai
P.O. BOX 17779
Jazfa, United Arab Emirates
Tel: +971 4 816 8300
contact_middleeast@turbomach.com

19
www.turbomach.com
CAT and CATERPILLAR are trademarks of Caterpillar Inc. Solar,
Insight System, Titan, Mars, Taurus, Centaur, Saturn, Mercury,
SoLoNOx are trademarks of Solar Turbines Inc. Turbomach is
the trademark of Turbomach S.A.

©2012 Turbomach. All rights reserved. BPHBTBM/512

Das könnte Ihnen auch gefallen