Sie sind auf Seite 1von 3

USP

MICROCODE VERSION 50-04-50-00/00


NEVER RELEASED
Newly supported features and functions for Version 50-04-50-00/00
NONE

The change of contents for Version 50-04-50-00/00

1 Setting Problems on LUSE Panel


Phenomena Total capacity of LUSE is calculated as product of the capacity of last
LDEV and number of LDEV, the following problems occur.
Case 1: When total LU capacity exceeded maximum value and capacity of
last LDEV was smaller than maximum capacity/number of LDEV, the
setting was available on panel but error was reported after selecting Apply.
Case 2: When the total LU capacity did not exceed the maximum value
and the capacity of the last LDEV was larger than the maximum
capacity/number of LDEV, the setting was unavailable on the panel.
Severity (High, Medium, Low) Medium
Conditions of Occurrence Case 1: Capacity of the last LDEV is smaller than the maximum
capacity/number of LDEV and the total LU capacity is more than 60 TB,
Case 2: Capacity of last LU is larger than the maximum capacity/number
of LDEV and the total LDEV capacity is less than 60 TB,
Affected Products/Version SVP: All
Fixed Product/Version SVP: 50-04-50/00
Category Open Volume Management
Changed Part SVP

2 LINK INCIDENT when Start-up with ESCON Connection


Phenomena In case of being connected with the ESCON channel, LINK INCIDENT
occurred on the host when PS-ON was performed.
Severity (High, Medium, Low) Low
Conditions of Occurrence Performing LCDG3 under following conditions when a host is connected
with a cable and is powered on.
1. PS-ON (ESCON PCB only),
2. PCB replacement (ESCON PCB only).
Causes and Updates The LCDG program has been modified to fix the problem.
Affected Products/Version LCDG: All
Fixed Product/Version LCDG: 50-00-02
Category ESCON
Changed Part LCDG3

HDS Confidential 1 of 3
3 Problem in displaying capacities in new license system
Phenomena If licensed capacity is “Frame Unlimited”, warning message displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence This problem occurs when all the conditions are met.
- Permanent key
- The licensed capacity is “Frame Unlimited”
- The system capacity exceeds 65,535 TB
Affected Products/Version SVP: All
Fixed Product/Version SVP: 50-04-50/00
Category Storage Navigator
Changed Part SVP

4 File transfer fails at the time of Configuration Update in dual


SVP configuration
Phenomena In a dual SVP configuration, if Configuration Update is performed right
after the micro program exchange, file transfer to the standby SVP may fail
and SIM 0x7ff201 (SSB:3336) "Standby SVP FAIL" may occur.
Severity (High, Medium, Low) Medium
Conditions of Occurrence This problem may occur when all the conditions are met.
1. Dual SVP
2. Either DKCMAIN/RAMBOOT/LCP/LCDG micro program exchange
or a periodic file transfer (1 PM/2 AM in HP) is performed.
(The file is transferred to the standby SVP in the background, and then PC
reboot of the standby SVP takes place.)
3. Right after that, either micro program exchange in master SVP or
Configuration Update is started again.
(After PC is rebooted after 3, the file is transferred to the standby SVP)
4. The standby SVP reboot after 2 and the file transfer to the standby SVP
after 3 occur at the same time.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 50-04-50/00
Category SVP
Changed Part SVP

HDS Confidential 2 of 3
5 Setting Problems on SVP
Phenomena Following problems occurred on SVP when the LDEV with the emulation
types whose last letter was "B" or "C" existed.
1. On the panel of LUNM, the SCSI path could not be added to these
LDEV.
2. On the Shadow Image for z/OS panel, these LDEV could not be paired
with the LDEV whose emulation types were 3390-3 and 3390-3B.
3. On the Universal Replicator for z/OS panel, these LDEV looked as if
they could be set as data volumes (In fact, the setting would cause an error
after selecting Apply).
4. On the True Copy for z/OS panel, these LDEV looked as if the pair
creating was possible (In fact, the setting would cause an error after
selecting Apply).
5. On the Volume Security panel, the LDEV security looked possible to set
to these LDEV though the SCSI path was already set (In fact, the setting
would cause an error after selecting Apply).
Severity (High, Medium, Low) Medium
Conditions of Occurrence The LDEV with the emulation types whose last letter is "B" or "C" exist.
Affected Products/Version SVP: 50-04-01/00 and higher
Fixed Product/Version SVP: 50-04-50/00
Category LUN Manager/Universal Replicator for z/OS/True Copy for z/OS/Shadow
Image for z/OS
Changed Part SVP

6 DKS2D-J cannot be installed


Phenomena Case 1: DKS2D-J146/DKS2D-J300FC cannot be installed.
Case 2: DKA having DKS2D-J146/DKS2D-J300FC cannot be replaced.
Severity (High, Medium, Low) Medium
Conditions of Occurrence These problems (1 and 2) occur when the following conditions are met.
Case 1: Install DKS2D-J146/DKS2D-J300FC when installing an
additional frame.
Case 2: Replace the DKA to which DKS2D-J146/DKS2D-J300FC is
connected.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-04-50-00/00
Category HDD
Changed Part DKCMAIN

HDS Confidential 3 of 3