The required heating water flow must be guaranteed in all The HWK 332 Econ Hydro Tower provides the complete heat
operating conditions for trouble-free operation of the heat pump. pump hydraulic system in the smallest of spaces, as it
In addition, the volume of hot water circulated must be combines a heat pump manager, a hot water buffer tank and a
sufficiently large to prevent cycle operation with short buffer tank connected in series as well as optimised pump units
compressor runtimes occurring. For this reason, the generator in one compact and space-saving casing. It can easily be
and consumer circuits are often hydraulically decoupled and a connected to an air-to-water heat pump installed outside via two
buffer tank connected in series is installed for expanding the hydraulic connecting lines and one electrical connecting cable.
circulated volume of the system. A separate cylinder requiring The integrated components for an unmixed heating circuit with
additional space is necessary for domestic hot water a circulating pump each in the generator circuit and the
preparation. consumer circuit ensure the required heating water flow and
secure trouble-free operation.