Sie sind auf Seite 1von 8

ELCAD AUCOTEC Command overview with short description

A
A Evaluate
AL Evaluate symbol placed last
AX Evaluate X range
AY Evaluate Y range
AF Evaluate window
AA Evaluate all
ALF Evaluate last window
ABORT Abort the editing process
ANS Set connections in symbol design
ASCII_WRITE Write ASCII page
AUTOWIRE 0-4, select automatic core symbols for connection

B
BV Page directory
BW Page change
BW+ Move one page back
BW- Move one page forward

C
C Connection (electrical connection)
C. Starting point is free
CP Starting point as node
C+ Starting point as constrained wiring +
C- Starting point as constrained wiring -
CA Starting point as symbol (configurable)
CB Starting point as symbol (configurable)
CC Starting point as symbol (configurable)
CD Starting point as symbol (configurable)
C End point according to option for end points. The same option as for the starting
points are applicable.
...P.+.,A,B,C,D
...P,+,-,A,B,C,D
C (*) Multi connection with selection
C (name) Multi connection with direct input of the connection type
C! Connection for macros
CAT cf. type
call_alwin(kill_mkr) Erase named label
call_alwin (config_auto_connect) Call automatic connection configuration
call_alwin (kfg_ge(("MULTICONNECT""))) Call multi connect configuration
call_alwin (kfg_ge(("VERB""))) Configuration of connection extensions
call_alwin (text_fmt) Call text editor (set or edit texts of several lines)
call_alwin(list_zl) Display assignment list
ELCAD AUCOTEC Command overview with short description

call_alwin (win_help(("helpfile"").([1]))) Call help


helpfile: wproject or wsymbol or wauco
call_alwin(chkfup(([2])))) Check Aucoplan function chart
call_alwin(vorverdr(("2""))) Read prewiring
call_alwin(vorverdr(("0""))) Erase prewiring
call_alwin(vorverdr(("1""))) Save prewiring
call_alwin(vorverdr(("2""))) Assign prewiring to device; EF, ALF should be used before
call
call_alwin(vorverdr (("2""))) Swap prewiring channel; E should be used before call; a RP
should be used after all prewiring calls
call_alwin(get_mass (("KABEL""))) ELCADinstall cable length without line with height
jump
call_alwin(get_mass (("KABEL_OM""))) ELCADinstall cable length without line
without height jump
call_alwin(get_mass (("KABEL_L""))) ELCADinstall cable length with line with
height jump
call_alwin(get_mass (("KABEL_L""))) ELCADinstall cable length with line without
height jump
call_alwin(sl_elcad) Layout diagram - place devices

D
DIALOG Call dialogue mask in symbol design
DEFAULT Set parameters to default
D Turn graphic element
DL Turn symbol placed last
DX Turn X range
DY Turn Y range
DF Turn window
DA Turn all
DLF Turn last window
DIALOG_EDIT Test dialogues in symbol design (dialogue mask for test inputs)
DXF_WRITE Print DXF page

E
E Edit
Edit on symbol: call the dialogue mask, respectively on AUCOPLAN symbols - call of the
table mask - edit lines/connections: call of the attributes
EL Edit symbol placed last
EX Edit X range
EY Edit Y range
EF Edit window
EA Edit all
ELF Edit last window
E (ONLINE) L,X,Y,F,A,LF all not evaluated
ELCAD AUCOTEC Command overview with short description

E (MASS) L,X,Y,F,A,LF all dimensions


E (TEX) L,X,Y,F,A,LF all texts
E (BMK) L,X,Y,F,A,LF all without item name
E (ARTIKEL) L,X,Y,F,A,LF all without article
E (N= ) L,X,Y,F,A,LF all symbol name=[TEXT]
E (T= ) L,X,Y,F,A,LF all symbol type=[NUMBER]
E (N!= ) L,X,Y,F,A,LF all symbol type<>[TEXT]
E (T!= ) L,X,Y,F,A,LF all symbol type<>[NUMBER]
END Return to main menu
End(1) Batch processing (in drawing editing mode)
END(2) Symbol design (in drawing editing mode)
END(3) Create parts list (in drawing editing mode)
END(4) Error list (in drawing editing mode)
EO Automatic symbol
EOL Automatic symbol - symbol placed last
EOX Automatic symbol - X range
EOY Automatic symbol - Y range
EOF Automatic symbol - window
EOA Automatic symbol - all
EOLF Automatic symbol - last window. The automatic features of the 1000 dialogues are
executed, if the page was not frozen and there are no manual entries.
ELLIPSE Ellipse
([LTY=n],[PEN=m]) Pre-assignment of line width and line type n:0 ... 8, m: 1 ... 6
EXTERN Determine terminal side as external side
EX_ANS Set external connection in symbol design
EDIT BMK Call item name editor in drawing editing mode

F
FILL Hatch
FT Swap form
FT (symbol name) Swap form with new form named
FB Edit form
FREEZE Freeze terminal and core numbers

G
G Form group from graphic elements
GX Form group - X range
GY Form group - Y range
GF Form group - window
GA Form group - all. In symbol design, variable groups as well. The code numbers 4003
and 4004 have to exist.
GRID Change background grid - active only up to the next BW (i.e. page change)
ELCAD AUCOTEC Command overview with short description

H
HOPPLA Undo last command. The page is reset and re-evaluated!

I
I Identification (identification mask is displayed)
IL Identification of symbol placed last
IN_ANS Set internal connections in symbol design
INTERN Determine terminal side as internal

K
K Copy (on the active page)
KL Copy last (on the active page)
KX Copy X range (on the active page)
KY Copy Y range (on the active page)
KF Copy window (on the active page)
KA Copy all (on the active page)
KLF Copy last window (on the active page)
K L,X,Y,F,A,LF (!) copy with editing (on the active page)
KEX Copy X range (from external page)
KEY Copy Y range (from external page)
KEF Copy window (from external page)
KEA Copy all (from external page)
KRS Circle
([LTY=n],[PEN=m]) Assign line width and type of line n:0 ... 8, m: 1 ....6

L
L Erase
LL Erase symbol placed last
LX Erase X range
LY Erase Y range
LF Erase window
LA Erase all
LLF Erase last window
LAYER Call layer menu
LAYER Control layer directly
([n].[+m],[-m] n: activate layer number (0 to 255)
m: layer number (1 to 255
+: layer visible on screen
-: layer invisible on screen
LIST LEISTEN List all terminal strips
LIST KLEMMEN List all terminals
LIST KLEMMENASCII List all terminals (ASCII format - field length 32 characters)
ELCAD AUCOTEC Command overview with short description

LIST BMK List all item names


LIST BMK ASCII List all item names (ASCII format - field length 32 characters)
LIN Graphical line
([LTY=n],[PEN=m] Pre-assignment of line width and type of linen: 0 ... 8, m: 1 ... 6
LIMITS Show geometry
LIMITS(n,m) Set geometry
m: X range maximum 1,638.35
n: Y range maximum 1,638.35
Active only until next BW (i.e. page change)!
LOGANS Set logical connection in symbol design

M
MX Copy X range (from external page)
MY Copy Y range (from external page)
MF Copy window (from external page)
MA Copy all (from external page)
ME Copy from a known macro
ME! The links created with the extension !" are not shortened during the copying process
(macro editing only).
MS Save macro named
ME/MS ([EBENE1],
[EBENE2]) With indication of level 1 and
level 2
ME(CB) Copy to ELCAD clipboard
MS(CB) Save to ELCAD clipboard. In the drawing levels, capital and small letters
are differentiated.
MKR Set macro in symbol design
MASS Call dimensioning menu
MECHANS Set mechanical connection in symbol design

N
N Navigate (cross-reference tracking)
NL Navigate symbol placed last
NORMAL Automatically determine the terminal side

P
PL Plot
PL(name) Plot directly (name of the plotter)
PL(number) Plot directly (number of the plotter)
PC Process connection
PC(name) Process connection with type of connection
ELCAD AUCOTEC Command overview with short description

R
R Reset evaluation
RL Reset evaluation - symbol placed last
RX Reset evaluation - X range
RY Reset evaluation - Y range
RF Reset evaluation - window
RA Reset evaluation - all
RLF Reset evaluation - last window
REC Rectangle
REC ([LTY=n],[PEN=m] Rectangle with line width and type of line n:0 ... 8, m: 1 ... 6
RP Refreshes the screen
RP(OT) Shows the translates in the page.
REPEAT Repetition of the next command or symbol

S
S Scale symbols
SL Scale symbol placed last
SX Scale X range
SY Scale Y range
SF Scale window
SA Scale all
SLF Scale last window
S L,X,Y,F,A,LF (value) Scale with factor given
SAVE Save
SE Read symbol in symbol design
SS Save symbol in symbol design
SR Temporarily save symbol in symbol design
SV Symbol directory in symbol design
SW Temporarily read symbol in symbol design
SYMBOL_DOCU List dialogues in symbol design
SYM_PASS_INPUT Symbol password in symbol design
SYM_PASS_CHANGE Change symbol password in symbol design
SYMBOL_ASCII_WRITE Print symbol in ASCII in symbol design
SPLINE Change line into spline
ST Show page status
SERVICE Service menu
SERVICE ON Service mode on
SERVICE OFF Service mode off
SERVICE AUCOTEC Service menu
SYM_DAT_DOCU List dialogue masks of all symbols of the currently selected symbol
library
SYM_DAT_ERROR List errors in the currently selected symbol file
SYM_DAT_UMSETZEN Convert symbol library to revision 5.1
SYM_DAT_VNS_WRITE Print read symbol file in VNS format
ELCAD AUCOTEC Command overview with short description

T
T Swap symbols
TL Swap symbol placed last
TEX Free text
TEST General test
TEST TEX Test text place holder
TEST SYMBOL Symbol reference points
TEST FRAME Capture frame
TEST VAR VAR points
diagonal arrow: VAR possible in X and Y direction
horizontal arrow: VAR possible in Y direction
vertical arrow: VAR possible in X direction
TEST ANS All connections
TEST MECHANS Mechanical linkage
TEST LOGANS Logical connections (cables, cores)
TEST INTERN Terminal - internal connections
TEST EXTERN Terminal - external connections
TEST VERB Test for open connections
TEST ADER Test cores without connection
TEST ARTIKEL Test - part number is missing
TEST BMK Test - item name is missing
TEST ONLINE Test not evaluated
TEST GRUPPE Marks the reference points of groups and the individual group
elements with coloured crosses
TEST KRS Marks the centres of circles and partial circles with coloured crosses
TEST LIN Marks the beginning, corner, and end points of lines, splines, and ellipses
TEST MASS The construction points of the dimensions are displayed
TEST MKR Displays the position and the dialogue number of symbols placed by MKR
TEST REC Marks the corner points of rectangles
TB LOAD (toolbar name) Load toolbar
TB UNLOAD Unload toolbar
TB UPDATE Reload toolbar after modification
TYPE Display of random file in drawing editing mode

U
UNGROUP Remove group (on group reference point)
UNDO Undo the last command. The page is reset and re-evaluated !
UNFILL Removes hatch set with FILL
UNFREEZE Release terminal and core numbers frozen with FREEZE
UNSPLINE Change spline in lines
ELCAD AUCOTEC Command overview with short description

V
V Move
VL Move symbol placed last
VX Move X range
VY Move Y range
VF Move window
VA Move all
VLF Move last window
VS Move symbol (in or out of connection)
VAR Extend Var symbol or move contact mirror
VARLIN Variable line in symbol design. Code number 4003 and 4004 dialogues have
to exist.
([LTY=n],[PEN=m]) pre-assignment of line width and type of line: n: 0 ... 8, m: 1 ... 6
VARREC Variable rectangle in symbol design. Code number 4003 and 4004 dialogues
have to exist
VARKRS Variable circle in symbol design. Code number 4013 or 4014 dialogue has to
exist.
([LTY=n],[PEN=m]) pre-assignment of line width and type of line: n: 0 ... 8, m: 1 ... 6
VNS_WRITE Print page in VNS format
VARTEX Texts which receive a variable location which depends on the dialogues for
height, width, and scale

X
X Mirror on X axis of graphical element
XL Mirror symbol placed last
XX Mirror X range
XY Mirror Y range
XF Mirror window
XA Mirror all
XLF Mirror last window

Y Z
Y Mirror on Y axis of graphical ZO Zoom in
element ZO(?) Call zoom in menu
YL Mirror symbol placed last ZO(n) Zoom in defined section - n: 1 ... 9
YX Mirror X range ZR Reset zoom: zoom out
YY Mirror Y range ZOOM_VIEW Switch zoom
YF Mirror window overview window on, respectively off
YA Mirror all (ona/off)
YLF Mirror last window ZO (max) Ideal zoom-in of the entire
page contents (without form frame)

Das könnte Ihnen auch gefallen