Sie sind auf Seite 1von 5

Project: Kinrara Residence 3-Aug-18

Description: SI analysis

GEOTECHNICAL CAPACITY OF SPUN PILE

Borehole, BH = BH1
Pile size = 600 mm Dia. Circular Pile
Pile base area, Ab = 0.283 m2
Pile perimeter = 1.884955592 m
F.O.S. for skin friction = 2
F.O.S. for end bearing = 3
Recommended Geotechnical capacity of the pile = 2150 kN
F.O.S Global = 2.5

Ultimate resistance of pile, Qf


Qf = base resistance (Qb) + shaft resistance (Qs) Ab = base area
Qf = (Ab * qf) + (As * fs) qf = bearing capacity of base
As = perimeter area of shaft
Meyerhof formula fs = shearing resistance per unit area
1. qf = Kb * N <= 400 * N (kN/m2) N = effective N-value at pile base
2. fs = Ks * Nave (kN/m2) Nave = average SPT value over the embeded length of pile within the soil stratum
Kb = base resistance factor
Ks = side resistance factor

Pile working load, Qw = (Qb / F.O.S. for end bearing) + (Qs / F.O.S. for skin friction) Limitation End Bearing = 18000 kPa
Limitation Shaft Friction = 100 kPa
SPT top level = 47.160 m Basement Level = 43.000
Pile cut-off level = 41.500 m
(1) (2) (1) + (2)
S.I Reduced Pre-bore Effective SPT Nave Type of soil Shaft area Kb Qb Ks Qs Cum. Qs Ultimate load Working load Working load Working load
OGL Level Pile Length pile length N-value (1-sand, 2-silt, As (m2) (kN) (kN) (kN) Qf (kN) Partial Qw (kN) Partial Qw (kN) Global, Qw (kN)
(m) (m) (m) (m) 3-clay) (Shaft) (End Bearing) (Shaft + E.Bear)
1.5 45.660 -2.7 -4.16 3 - 2 - 200 - 2 - - - - - #VALUE! -
3.0 44.160 -1.2 -2.66 4 - 2 - 200 - 2 - - - - - #VALUE! -
4.5 42.660 0.3 -1.16 5 - 2 - 200 - 2 - - - - - #VALUE! -
6.0 41.160 1.8 0.34 7 7 2 0.640884901 200 395.8407 2 8.972389 9 405 4 132 136 162
7.5 39.660 3.3 1.84 10 8.5 2 2.827433388 200 565.4867 2 48.06637 57 623 29 188 217 249
9.0 38.160 4.8 3.34 17 13.5 2 2.827433388 200 961.3274 2 76.3407 133 1095 67 320 387 438
10.5 36.660 6.3 4.84 28 22.5 2 2.827433388 200 1583.363 2 127.2345 261 1844 130 528 658 738
12.0 35.160 7.8 6.34 42 35 2 2.827433388 200 2375.044 2 197.9203 459 2834 229 792 1021 1133
13.5 33.660 9.3 7.84 100 71 2 2.827433388 200 5089.38 2 282.7433 741 5831 371 1696 2067 2332
15.0 32.160 10.8 9.34 100 100 2 2.827433388 200 5089.38 2 282.7433 1024 6113 512 1696 2208 2445
15.2 32.000 11.0 9.5 100 100 2 0.301592895 200 5089.38 2 30.15929 1054 6144 527 1696 2224 2457
Project: Kinrara Residence 3-Aug-18
Description: SI analysis

GEOTECHNICAL CAPACITY OF SPUN PILE

Borehole, BH = BH2
Pile size = 600 mm Dia. Circular Pile
Pile base area, Ab = 0.283 m2
Pile perimeter = 1.884955592 m
F.O.S. for skin friction = 2
F.O.S. for end bearing = 3
Recommended Geotechnical capacity of the pile = 2150 kN
F.O.S Global = 2.5

Ultimate resistance of pile, Qf


Qf = base resistance (Qb) + shaft resistance (Qs) Ab = base area
Qf = (Ab * qf) + (As * fs) qf = bearing capacity of base
As = perimeter area of shaft
Meyerhof formula fs = shearing resistance per unit area
1. qf = Kb * N <= 400 * N (kN/m2) N = effective N-value at pile base
2. fs = Ks * Nave (kN/m2) Nave = average SPT value over the embeded length of pile within the soil stratum
Kb = base resistance factor
Ks = side resistance factor

Pile working load, Qw = (Qb / F.O.S. for end bearing) + (Qs / F.O.S. for skin friction) Limitation End Bearing = 18000 kPa
Limitation Shaft Friction = 100 kPa
SPT top level = 47.500 m Basement Level = 43.000
Pile cut-off level = 41.500 m
(1) (2) (1) + (2)
S.I Reduced Pre-bore Effective SPT Nave Type of soil Shaft area Kb Qb Ks Qs Cum. Qs Ultimate load Working load Working load Working load
OGL Level Pile Length pile length N-value (1-sand, 2-silt, As (m2) (kN) (kN) (kN) Qf (kN) Partial Qw (kN) Partial Qw (kN) Global, Qw (kN)
(m) (m) (m) (m) 3-clay) (Shaft) (End Bearing) (Shaft + E.Bear)
1.5 46.000 -3.0 -4.5 3 - 2 - 200 - 2 - - - - - #VALUE! -
3.0 44.500 -1.5 -3 4 - 2 - 200 - 2 - - - - - #VALUE! -
4.5 43.000 0.0 -1.5 7 - 2 - 200 - 2 - - - - - #VALUE! -
6.0 41.500 1.5 0 9 9 2 0 200 508.938 2 0 0 509 0 170 170 204
7.5 40.000 3.0 1.5 10 9.5 2 2.827433388 200 565.4867 2 53.72123 54 619 27 188 215 248
9.0 38.500 4.5 3 11 10.5 2 2.827433388 200 622.0353 2 59.3761 113 735 57 207 264 294
10.5 37.000 6.0 4.5 16 13.5 2 2.827433388 200 904.7787 2 76.3407 189 1094 95 302 396 438
12.0 35.500 7.5 6 32 24 2 2.827433388 200 1809.557 2 135.7168 325 2135 163 603 766 854
13.5 34.000 9.0 7.5 100 66 2 2.827433388 200 5089.38 2 282.7433 608 5697 304 1696 2000 2279
15.0 32.500 10.5 9 100 100 2 2.827433388 200 5089.38 2 282.7433 891 5980 445 1696 2142 2392
15.5 32.000 11.0 9.5 100 100 2 0.942477796 200 5089.38 2 94.24778 985 6074 492 1696 2189 2430
Project: LRT3 STATION 14
Description: Convert 1200 mm diameter bored pile(8000kN) to 600 diameter spun pile

GEOTECHNICAL CAPACITY OF SPUN PILE

Borehole, BH = CBH SI-13 For test pile


Pile size = 600 mm Dia. Circular Pile
Pile base area, Ab = 0.283 m2
Pile perimeter = 1.8849555922 m
F.O.S. for skin friction = 2
F.O.S. for end bearing = 2.5
Recommended Geotechnical capacity of the pile = 2300 kN
F.O.S Global = -

Ultimate resistance of pile, Qf


Qf = base resistance (Qb) + shaft resistance (Qs) Ab = base area
Qf = (Ab * qf) + (As * fs) qf = bearing capacity of base
As = perimeter area of shaft
Meyerhof formula fs = shearing resistance per unit area
1. qf = Kb * N <= 400 * N (kN/m2) N = effective N-value at pile base
2. fs = Ks * Nave (kN/m2) Nave = average SPT value over the embeded
Kb = base resistance factor
Ks = side resistance factor

Pile working load, Qw = (Qb / F.O.S. for end bearing) + (Qs / F.O.S. for skin friction)

SPT top level = 30.000 m Basement Level = 0.000


Pile cut-off level = 30.000 m

S.I Reduced Pre-bore Effective SPT Nave Type of soil Shaft area Kb Qb
OGL Level Pile Length pile length N-value (1-sand, 2-silt, As (m2) (kN)
(m) (m) (m) (m) 3-clay)
3.0 27.000 -27.0 3 38 38 1 5.6548667765 200 1696.46
4.5 25.500 -25.5 4.5 6 22 1 2.83 200 339.29
6.0 24.000 -24.0 6 14 10 1 2.83 200 791.68
7.5 22.500 -22.5 7.5 16 15 1 2.83 200 904.78
9.0 21.000 -21.0 9 9 12.5 1 2.83 200 508.94
10.5 19.500 -19.5 10.5 11 10 1 2.83 200 622.04
12.0 18.000 -18.0 12 12 11.5 1 2.83 200 678.58
13.5 16.500 -16.5 13.5 83 47.5 1 2.83 200 1696.46
15.0 15.000 -15.0 15 80 81.5 1 2.83 200 1696.46
16.5 13.500 -13.5 16.5 200 140 1 2.83 200 1696.46
18.0 12.000 -12.0 18 200 200 1 2.83 200 1696.46
19.5 10.500 -10.5 19.5 200 200 1 2.83 200 1696.46
21.0 9.000 -9.0 21 200 200 1 2.83 200 1696.46
22.5 7.500 -7.5 22.5 200 200 1 2.83 200 1696.46
24.0 6.000 -6.0 24 200 200 1 2.83 200 1696.46
25.5 4.500 -4.5 25.5 200 200 1 2.83 200 1696.46
27.0 3.000 -3.0 27 200 200 1 2.83 200 1696.46
28.5 1.500 -1.5 28.5 200 200 1 2.83 200 1696.46
Type of Soil
1
2
3

ring capacity of base


imeter area of shaft
aring resistance per unit area
ctive N-value at pile base
average SPT value over the embeded length of pile within the soil stratum
se resistance factor
e resistance factor

Limitation End Bearing = 6000 kPa


Limitation Shaft Friction = 175 kPa

(1) (2) (1) + (2)


Ks Qs Cum. Qs Ultimate load Working load Working load
(kN) (kN) Qf (kN) Partial Qw (kN) Partial Qw (kN)
(Shaft) (End Bearing)
2 429.7699 430 2126 215 679 893 Prebore
2 124.41 554 893 277 136 413 Prebore
2 56.55 611 1402 305 317 622 Prebore
2 84.82 696 1600 348 362 710 Prebore
2 70.69 766 1275 383 204 587 Prebore
2 56.55 823 1445 411 249 660 Prebore
2 65.03 888 1566 444 271 715 Prebore
2 268.61 1156 2853 578 679 1257 Prebore
2 460.87 1617 3314 809 679 1487 Prebore
2 494.80 2112 3809 1056 679 1735 Prebore
2 494.80 2607 4303 1303 679 1982 Prebore
2 494.80 3102 4798 1551 679 2229 Prebore
2 494.80 3596 5293 1798 679 2477 Prebore
2 494.80 4091 5788 2046 679 2724 Prebore
2 494.80 4586 6283 2293 679 2972 Prebore
2 494.80 5081 6777 2540 679 3219 Prebore
2 494.80 5576 7272 2788 679 3466 Prebore
2 494.80 6070 7767 3035 679 3714 Prebore
Type of Soil Kb Ks
Sand 200 2.0
Silt 200 2.0
Clay 45 2.5

Das könnte Ihnen auch gefallen