Features:

Concealed installation.
Compact design.
Available in electric,
LPHW or ambient.
Grille can be supplied in a
large range of colours.
Energy saving controls
option available.
Application Function Tests
The Diffusion Eclipse recessed air curtain has been designed for a Each unit shall be function tested at our factory to ensure correct
vertical concealed application where the client does not want see a operation. All electrical components shall be tested to ensure each unit
unit within area. The unit shall be vertical mounted within a recess/ and its associated wiring complies with the 17th edition of IEE. The
bulkhead construction thus only showing the discharge & return air unit shall be manufactured in accordance with BS EN ISO 9001:2000
grilles. The unit can be supplied in water heating, electric heating or quality standards.
ambient. The unit comes in standard lengths of 1700, 2100, 2600 &
3000mm, however we do offer a bespoke service allowing us to adjust Standard Controls
the unit size to fit any building application. Electric version: Supplied with a remote control plate housing on/
off, speed high/low, heat off, low and high, finished in satin chrome as
Chassis standard, suitable for fitting onto a standard two gang, recessed or sur-
The chassis shall be manufactured from heavy gauge galvanised face mount, electrical back box. The unit can be used in ambient mode,
mild steel sheet, with burr free edges and a natural finish, formed by using the fans only setting.
and strengthened to provide a rigid and distortion free construction. LPHW version: Supplied with a remote control plate housing 4 speeds/
Maintenance access shall be via the removable return air filter. off, finished in satin chrome as standard, suitable for fitting onto a
standard two gang, recessed or surface mount, electrical back box.
Fans assembly
The unit shall be fitted with a high output permanent spilt phase Energy Controls (Optional)
capacitor, continuously rated and complete with a built in thermal Our award winning energy saving controls system offers state of the
overload protection, complying with BS 2048 1961 part 1 and art technology that allows the end user closer control of the equipment.
BS5000. The fans shall be double inlet, double width centrifugal type The controls function by using an off coil sensor which will restrict the
dynamically balanced in two planes according to DIN standards BS leaving air temperature (solid state relays on electric & 2 or 3 port
ISO 1940. The motors shall be insulated to BS 2757 (class B). valves on LPHW) to a set value (40ºC as standard but this is adjust-
able). Return and outside temperature sensors can be added into the
Heat Exchanger (LPHW Version) system making it fully automatic, thus not needing manual changeover
Heat exchanger matrixes shall be manufactured from solid drawn of summer/winter operation.
copper tubes; mechanically expanded into accurately pre-formed
collars in rippled plate type aluminium fins. Multi circuit designs shall The controller also offers as standard inputs for remote BMS monitor-
be incorporated ensuring maximum thermal performance efficiency, ing, common fault signal, BMS on/off, BMS summer/winter, BMS
headers unifying the circuits shall terminate in plain tail connections speed control, occupancy sensor/door switch and high heat temperature
on 40mm centres. Heating exchanger headers shall incorporate trip. The LCD remote control plate houses speeds, on/off control, plus
manually operated key pattern air vents and drains. Heat exchangers fault indications.
shall be suitable for operating at system pressures up to 12 bar, tested
to 30 bar dry air / nitrogen at manufacture, and subsequently leak
Optional Extras
Low water temperature cut out: Provides automatic shutdown of the fan/
tested again when fitted with valve sets at our works. motor when boilers have been switched off (standard controls only).
Electric Elements Summer/Winter switch (manual): Used in conjunction with the room
Electric heating elements shall be manufactured from 8mm fully thermostat and/or low water temperature cut out, this will allow the fan
sheathed stainless steel rods, with spiral fin on a 4mm pitch. A only to run for air movement (standard controls only).
manual re-set high temperature cut-out shall be fitted in accordance Remote thermostat: Available in adjustable or tamperproof (standard &
with standard safety requirements. Energy saving controls).
The element construction shall comply with BS7351 – 1990. BMS interface relay: 24vac relay and base (standard controls only).
Fault indication relay: current sensitive relay to indicate fault alarm from
Filters unit (standard controls only).
Fitted as standard the Diffusion “eco” filter shall be made of a fine 2 or 3 port valves (standard controls only).
woven mesh manufactured from galvanised steel wire, welded to a
rigid galvanised steel support frame; retained on the unit via thumb Return air sensor: Mounted integral to the unit (energy controls only).
screws. The “eco” filter shall be capable of being vacuum cleaned Outside temperature sensor: To detect outside conditions (energy controls
whilst fitted to the unit and removable for cleaning elsewhere if only).
required. PIR Sensor: To offer automatic on/off control of the unit (energy controls
only).
Quality testing
When fully assembled each unit shall be subjected to thorough BMS Fault Signal Relay: 12VDC relay and base to indicate fault alarm
mechanical examination, be run tested and function tested where from unit (energy controls only).
possible; and need to have passed a series of electrical compliance *Please note that if our energy controller is utilized on our electric
checks prior to being QC approved in accordance with our BS EN ISO units, the above noise levels can be significantly reduced, as the air
9001:2000 quality standards; ready for packing and dispatch. volumes can be lowered.
Performance Details

Eclipse LPHW
Speed Setting / Airflow / dB(A) / Guide NR Heating Performance Data ‘A’ Heating Performance Data ‘B’ Electrical & Mechanical Data

Electrical Supply
Temperatures °C

Temperatures °C

Maximum Start
Heating Output

Heating Output

Operating / Full
Acoustic Guide
Individual Unit

Pressure Drop

Pressure Drop

Load Current
Motor Power

Run Current

Unit Weight
LPHW Flow

LPHW Flow
at 3 meters
Air Volume

Noise level

Hot Water

Hot Water

Hot Water

Hot Water

Fan Power
Fan Speed

Flow Rate

Flow Rate
Hydraulic

Hydraulic
& Return

& Return
Reference

Specific
Setting
Model

L/M/H/B l/s dB(A) NR kWatts F / R l/s kPa kWatts F / R l/s kPa V/ph/Hz Watts Amps Amps W/l/s kg

Low 280 33 40 8.6 82/71 0.19 3.1 7.0 80/60 0.09 0.7 124 1.6 0.5 0.44
Standard
Capacity
1700W


Medium 360 41 47 10.3 82/71 0.23 4.2 8.5 80/60 0.10 1.0 200 2.7 0.9 0.56
230/1/50 91
High 460 47 52 12.1 82/71 0.27 5.8 9.9 80/60 0.12 1.3 298 4.0 1.3 0.65


Boost 600 52 56 14.3 82/71 0.32 7.9 11.7 80/60 0.14 1.8 454 6.0 2.0 0.76

Low 280 33 40 5.6 70/50 0.07 0.4 2.5 60/40 0.03 0.1 124 1.6 0.5 0.44
Capacity
1700W


Medium 360 41 47 6.9 70/50 0.08 0.6 2.8 60/40 0.03 0.2 200 2.7 0.9 0.56
High

230/1/50 91

High 460 47 52 8.4 70/50 0.10 0.9 3.0 60/40 0.04 0.2 298 4.0 1.3 0.65


Boost 600 52 56 10.0 70/50 0.12 1.2 3.3 60/40 0.04 0.2 454 6.0 2.0 0.76

Low 400 33 40 12.5 82/71 0.28 7.5 10.5 80/60 0.13 1.9 175 2.3 0.8 0.44
Standard
Capacity
2100W


Medium 550 41 47 15.6 82/71 0.35 11.4 13.1 80/60 0.16 2.8 293 4.0 1.3 0.53
230/1/50 106
High 710 47 52 18.3 82/71 0.41 15.3 15.3 80/60 0.19 3.7 460 6.1 2.0 0.65


Boost 875 52 56 20.9 82/71 0.46 20.0 17.4 80/60 0.21 4.7 652 8.5 2.8 0.75

Low 400 33 40 9.1 70/50 0.11 1.2 3.6 60/40 0.04 0.3 175 2.3 0.8 0.44
Capacity
2100W


Medium 550 41 47 11.6 70/50 0.14 1.9 6.4 60/40 0.08 0.7 293 4.0 1.3 0.53
High

230/1/50 106
High 710 47 52 13.6 70/50 0.17 2.5 8.1 60/40 0.10 1.0 460 6.1 2.0 0.65


Boost 875 52 56 15.5 70/50 0.19 3.2 9.5 60/40 0.12 1.3 652 8.5 2.8 0.75

Low 475 33 39 15.1 82/71 0.34 12.7 12.8 80/60 0.16 3.0 210 2.7 0.9 0.44
Standard
Capacity
2600W


Medium 660 42 47 19.0 82/71 0.42 18.5 16.1 80/60 0.20 4.7 352 4.7 1.6 0.53
230/1/50 127
High 850 48 53 22.3 82/71 0.50 25.4 18.9 80/60 0.23 6.3 552 7.3 2.4 0.65


Boost 1050 53 57 25.5 82/71 0.57 32.0 21.5 80/60 0.26 7.9 783 10.2 3.4 0.75

Low 475 33 39 12.7 70/50 0.15 1.9 7.5 60/40 0.09 0.7 210 2.7 0.9 0.44
Capacity
2600W


Medium 660 42 47 16.1 70/50 0.20 2.8 10.2 60/40 0.12 1.2 352 4.7 1.6 0.53
High

230/1/50 127
High 850 48 53 18.9 70/50 0.23 3.8 12.3 60/40 0.15 1.7 552 7.3 2.4 0.65


Boost 1050 53 57 21.7 70/50 0.26 4.9 14.3 60/40 0.17 2.4 783 10.2 3.4 0.75

Low 475 33 39 16.4 82/71 0.37 16.8 14.2 80/60 0.17 4.4 210 2.7 0.9 0.44
Standard
Capacity
3000W


Medium 660 42 47 20.6 82/71 0.46 25.8 17.6 80/60 0.22 6.6 352 4.7 1.6 0.53
230/1/50 142
High 850 48 53 24.6 82/71 0.55 36.0 21.1 80/60 0.26 9.2 552 7.3 2.4 0.65


Boost 1050 53 57 26.2 82/71 0.58 40.0 24.0 80/60 0.29 11.2 783 10.2 3.4 0.75

Low 475 33 39 14.0 70/50 0.17 2.6 9.1 60/40 0.11 1.2 210 2.7 0.9 0.44
Capacity
3000W


Medium 660 42 47 17.6 70/50 0.21 4.0 11.8 60/40 0.14 1.9 352 4.7 1.6 0.53
High

230/1/50 142
High 850 48 53 21.2 70/50 0.26 5.6 14.4 60/40 0.17 2.8 552 7.3 2.4 0.65


Boost 1050 53 57 24.3 70/50 0.30 7.1 16.7 60/40 0.20 3.6 783 10.2 3.4 0.75

Eclipse ELECTRIC

Speed Setting / Airflow / dB(A) / Guide NR Electrical & Mechanical Data

Heating Element
/ Full Load Current
Maximum Start
Acoustic Guide

Fans Only / Full


Individual Unit

Load Current
Motor Power

Run Current

Unit Weight
Specific Fan
at 3 meters
Air Volume

Noise level
Fan Speed

per Phase
Electrical
Reference

Heating
Setting

Output

Supply

Power
Model



L/M/H/B l/s dB(A) NR kWatts V/ph/Hz Watts Amps Amps Amps W/l/s kg

Low 280 33 40 12 124 1.6 0.5 17.2 0.44

Medium 360 41 47 12 200 2.7 0.9 17.6 0.56


1700E

415/3/50 91
High 460 47 52 12 298 4.0 1.3 18.0 0.65

Boost 600 52 56 12 454 6.0 2.0 18.7 0.76

Low 400 33 40 18 175 2.3 0.8 25.9 0.44

Medium 550 41 47 18 293 4.0 1.3 26.4 0.53


2100E

415/3/50 106
High 710 47 52 18 460 6.1 2.0 27.1 0.65

Boost 875 52 56 18 652 8.5 2.8 27.9 0.75

Low 475 33 39 18 210 2.7 0.9 26.0 0.44

Medium 660 42 47 18 352 4.7 1.6 26.7 0.53


2600E

415/3/50 127
High 850 48 53 18 552 7.3 2.4 27.5 0.65


Boost 1050 53 57 18 783 10.2 3.4 28.5 0.75

Low 475 33 39 24 210 2.7 0.9 34.3 0.44

Medium 660 42 47 24 352 4.7 1.6 35.0 0.53


3000E

415/3/50 142
High 850 48 53 24 552 7.3 2.4 35.8 0.65


Boost 1050 53 57 24 783 10.2 3.4 36.8 0.75

dB(A) Figure Qualification


The dB(A) figures quoted are calculated by applying the A-weighting adjustment to the sound power (LW)
levels; at frequencies from 63Hz to 8kHz which have been determined by measurement in reverberant
rooms, at each speed setting.
The resultant figures are then adjusted for a distance of 3 meters to the listener:- dB(A) at 3 meters..

NR Guide Qualification
Calculations detailed in the CIBSE Guide for Sound Control are used to model the combined Inlet (and
Case Radiated where applicable) sound power levels and Discharge sound power levels for each unit and
speed setting; providing a Guide NR rating for the units when installed in a typical manner.

Room size based on a heating load of: 100Watts per square metre.

Room acoustic characteristics: Medium Live.

Distance to listener: 1.5 metres.

Please note that our NR figure should Please note with standard controls a two speed remote switch
be considered as a guide only. plate will be supplied and this will be wired to High & Boost
speeds.
There are many factors which influence
the actual resultant NR level within a Should you require the lower noise ratings of Low or Medium
given space; thus we would recommend speed then the optional energy saving controls will need to be
that for a more accurate prediction of purchased.
the resultant NR level an independent
acoustic specialist be employed. Coils Tails: 22mm plain copper

Eclipse - LPHW, Electric and Ambient Recessed
ECLIPSE
Air Curtain General Arrangement Details
LPHW, ELECTRIC AND AMBIENT RECESSED AIR CURTAIN
GENERAL ARRANGEMENT DETAILS
REAR ELEVATION. SIDE ELEVATION. FRONT ELEVATION.

WALL MOUNTED INLET FILTER


CONTROL PLATE

CONTROLS

DISCHARGE GRILLE
ENCLOSURE
A

B
INLET FILTER

450
OPTIONAL HANDINGS FOR INLET
FILTERS AND CONTROLS ENCLOSURE UNDERSIDE UNIT FIXING HOLES
REAR ELEVATION 4 PLACES
LH REAR INLET FILTERS
LEFT HAND INLET FILTERS AND CONTROLS ENCLOSURE
75 SPIGOT
GRILLE

AND CONTROLS ENCLOSURE. (STANDARD CONFIGURATION


AS SHOWN ABOVE).
AIRFLOW
450

86

RH
RIGHT HAND INLET FILTERS
AND CONTROLS ENCLOSURE
(AS SHOWN HERE).

DISCHARGE GRILLE LPHW COIL


CONNECTIONS DIMENSIONS LPHW COIL
MODEL (ALL VARIANTS) CONNECTIONS
THE INLET FILTERS AND CONTROLS ENCLOSURE ARE FITTED ON SIZE A B Htg.
THE REAR OF THE UNIT AS STANDARD, BUT CAN ALTERNATIVELY BE 1700 1710 1710 22
FITTED ON EITHER SIDE OF THE UNIT IF REQUESTED. 2100 2110 2104 22
2600 2610 2600 22
THE HANDING OF THE INLET FILTERS AND THE CONTROLS 3000 3010 3000 22
ENCLOSURE IS DETERMINED BY LOOKING INTO THE DISCHARGE
GRILLE AS SHOWN IN THE DETAIL ABOVE.
ECLIPSE GA Catalogue r1 A1/32927
‘ Established in 1960,
Diffusion has over 50 years
experience in producing
environmental solutions
via the manufacture of heating,
air conditioning and
ventilating products.

Diffusion Environmental Systems


47 Central Avenue, West Molesey, Surrey KT8 2QZ
Tel: (+44) 020 8783 0033 Fax: (+44) 020 8783 0140
Email: diffusion@etenv.co.uk www.diffusion-group.co.uk