Product Overview
Low-profile smoke detector design The System Sensor 2151 low-profile photoelectronic smoke detector is UL listed to
UL 268A specifically for use in no-flow/low-flow air-handling systems. It’s designed
Low standby current
for installations where a standard Venturi principle duct smoke detector is unsuit-
Two LEDs “blink” in standby able. This is the perfect combination for installation in ducts where the air velocity is
below 500 fpm or for duct sizes as small as 8 inches in diameter.
Detector head plugs easily into base
Built-in test switch Pendant mounted in a standard electrical box within the duct, the twist-in/twist-
Built-in tamper-resistant feature
out head allows easy removal from the base for quick cleaning and mainte-
nance. The detector can be combined with the System Sensor B114LP 120VAC
Field sensitivity metering of detector to base or the B114LPBT 24VAC/DC base.
meet the requirements of NFPA 72
Designed for mounting on standard The APA451, Remote Annunciator with Piezo Alarm, can also be connected to
electrical box provide an audible and visible indication of smoke detector status.
SEMS screws for easy wiring and positive
wire retention
}
8 N.O. Alarm Relay BLACK LEADS
TRANSFORMER
9 N.O. Form A PRIMARY 2 EOL
10 C. Initiation 14
5 13
11 C. Contacts 1 SPECIFIED
BY PANEL
}
12
12 N.O. Alarm Relay MANUFACTURER
6 11
13 N.C. Form C 120 VAC 7 10
8 9
14 C. Auxiliar y Contacts
FIRE
ALARM ALARM INITIATION LOOP
CONTROL
PANEL
FAN/DAMPER
POWER CONTROL
(+) (+)
RA400Z RA400Z
(–) (Optional) (–) (Optional)
RELEASING
DEVICE
3 4 3 4
BLACK LEADS
TRANSFORMER
PRIMARY 2 2 EOL
14 14
5 13 5 13 SPECIFIED
1 1
12 12 BY PANEL
120 VAC 120 VAC
MANUFACTURER
6 11 6 11
7 10 7 10
8 9 8 9
FIRE
ALARM ALARM INITIATION LOOP
CONTROL
PANEL
RELEASING
POWER DEVICE RELEASING
POWER DEVICE
3 Not Used
4 Remote Annunciator (–)
5 RTC (–)
6
7 }
N.O. Super visor y Relay
N.O. Form A Contacts
}
8 N.O. Alarm Relay 4
3
9 N.O. Form A
10 C. Initiation
11 C. Contacts 2
}
14
12 N.O. Alarm Relay
5 13
13 N.C. Form C 1
24 VACrms/DC 12
14 C. Auxiliar y Contacts
6 11
7 10
8 9
FAN / DAMPER
POWER H0269-00
SHUTDOWN
3 APA451 3 APA451
2 2
1 (Optional) 1 (Optional)
RELEASING RELEASING
DEVICE DEVICE
3 4 3 4
2 2 EOL
14 14
5 13 5 13 SPECIFIED
1 1
12 12 BY PANEL
24 VACrms/DC 24 VACrms/DC
MANUFACTURER
6 11 6 11
7 10 7 10
8 9 8 9
FIRE
ALARM ALARM INITIATION LOOP H0268-00
CONTROL
PANEL
SUPERVISORY SUPERVISORY
RELAY RELAY
EOL
2 2
TEST COIL (+)
3 3
FIELD
INSTALLED 4-POSITION
4 JUMPER 4
TERMINAL
BLOCK
5 5
RTC (–)
TEST
COIL ALARM
ALARM
ALARM POWER
RESET
Ordering Information
© 2004 System Sensor. The company reserves the right to change product specifications without notice. A05-1018-002•01/04•#1100