HEAT LOSS FROM INSULATED PIPE


B y C h e G u i d e ( H t t p s : // C h e g u i d e . C o m /A u t h o r /A n u k a t / ) | D e c e m b e r 1 9 , 2 0 1 5
( H t t p s : // C h e g u i d e . C o m / 2 0 1 5 / 1 2 / H e a t - L o s s - F r o m - I n s u l a t e d - P i p e / ) |

Heat loss/gain takes place from a pipe carrying hotter/ colder fluid than ambient temperature. Insulation reduces the
heat loss to surroundings. Heat loss depends upon number of factors like insulation thickness, ambient temperature,
wind speed etc. This article shows how to calculate heat loss from an insulated pipe and a bare pipe to surroundings.

Example
A 3″ Carbon steel pipe is carrying hot oil at 180°C and insulated with 50 mm thick calcium silicate insulation. Insulation is
cladded with a sheet with surface emissivity of 0.9. Ambient temperature is 28°C and wind velocity is 3.5 m/s. Calculate
surface temperature and heat loss from insulated and bare pipe.

Overall heat transfer coe icient of an insulated pipe is defined as following.

https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/ 1/12
4/14/2018 Heat Loss from Insulated Pipe – ChE Guide

where, kPIPE, kINSULATION are thermal conductivity of pipe and insulation. hin is heat transfer coe icient for fluid flowing
in pipe and hair is heat transfer coe icient due to air flowing outside the pipe. The first two terms of denominator in
above equation are generally smaller compared to remaining terms and can be neglected. For this example first term
due to pipe fluid is ignored.

Air Side Heat Transfer Coef cient, hAIR


Air side heat transfer is due to combined e ect of convection and radiation. Assume a temperature at cladding surface
t_surface and steel pipe surface t_interface. Calculate average air film temperature as following.

t_average = ( t_surface + t_ambient )/ 2

Estimate thermodynamic properties of air like thermal conductivity (k), viscosity (μ), expansion coe icient (β =
1/t_average), air density (ρ), kinematic viscosity (ν), specific heat (Cp) and thermal di usivity (α) at average air film
temperature. These properties are available in literature in form of tables, these can be fitted into a polynomial form
using excel’s LINEST function. Reynolds’s number (Re), Prandtl number (Pr) and Rayleigh number (Ra) are calculated
based on above properties.

h_radiation
Heat transfer coe icient due to radiation is calculated using following relation.

h_radiation = σ ε (t_surface4 - t_ambient4)/ (t_surface - t_ambient)

where σ is Stefan Boltzmann coe icient and ε is emissivity for cladded surface.

h_convection
Convective heat transfer coe icient comprises of forced and free convection. Forced convection can be modeled
based on correlation by Churchill and Bernstein.

h_forced = Nu.k_air / D3

https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/ 2/12
4/14/2018 Heat Loss from Insulated Pipe – ChE Guide

Free convection is calculated based on correlation by Churchill and Chu.

h_free = Nu.k_air / D3

Combined heat transfer coe icient due to forced and free convection is calculated using following relation.

Nu_combined = ( Nu_forced 4 + Nu_free 4) 0.25

h_convection = Nu_combined.k_air / D3

Air side heat transfer coe icient is calculated as following.

h_air = h_radiation + h_convection

Overall Heat Transfer Coef cient, U


Thermal conductivity for insulation material and pipe is available in literature and depends upon temperature. It can
be fitted into a polynomial equation using LINEST function in excel. Heat transfer resistance due to pipe and insulation
is calculated using following relation.

r_pipe = D3.ln(D2/D1) / 2.k_pipe


r_insulation = D3.ln(D3/D2) / 2.k_insulation

Overall heat transfer coe icient is calculated as.

r_overall = r_pipe + r_insulation + 1/h_air


U = 1/r_overall

Heat flowing through insulation is estimated.

Q = (t_operating - t_ambient)/r_overall

A revised estimate for interface and surface temperature is made.

t_interface = t_operating - Q.r_pipe


t_surface = t_interface - Q.r_insulation

Above steps are repeated with these new estimates till there is negligible di erence in temperature.

https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/ 3/12
4/14/2018 Heat Loss from Insulated Pipe – ChE Guide

Heat loss per unit length of pipe is estimated as following.

HeatLoss = πD3 Q

Bare Pipe
For heat loss from bare pipe all above steps are repeated with resistance due to insulation not considered.

r_pipe = D2.ln(D2/D1) / 2.k_pipe


r_overall = r_pipe + 1/h_air

For this example surface temperature and heat loss are as following.

Spreadsheet for Heat Loss from Insulated Pipe (https://cheguide.com/wp-


content/uploads/2016/07/Heat_Loss_Insulated_Pipe.xlsx)

 Facebook  Twitter  Google+  LinkedIn

Heat Transfer (Https://Cheguide.Com/Category/Heat-Transfer/)


Bare Pipe (Https://Cheguide.Com/Tag/Bare-Pipe/), Convection (Https://Cheguide.Com/Tag/Convection/), Heat Loss
(Https://Cheguide.Com/Tag/Heat-Loss/), Insulated Pipe (Https://Cheguide.Com/Tag/Insulated-Pipe/), Radiation
(Https://Cheguide.Com/Tag/Radiation/)

31 Replies to “Heat Loss from Insulated Pipe”


https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/ 4/12
4/14/2018 Heat Loss from Insulated Pipe – ChE Guide

Hidrotete says:

January 20, 2016 at 4:10 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-58)


In the calculation of the overall heat transfer coe icient. We have 4 resistance: fluid, pipe, insulation and air.
, I think it is required the Hconvection of the fluid, doesn’t it? I don’t know a correlation inside the pipe but I
think it is required. does anybody agree with me?

CheGuide says:

January 20, 2016 at 11:12 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-59)


For above calculations, resistance due to fluid is ignored as it is generally small compared to other terms
for turbulent flow inside pipe. But Hconvection can always be added in overall heat transfer coe icient as
mentioned below :

John Shinas says:

March 3, 2016 at 9:12 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-450)


Do you have an example made up for multiple layers of insulation? That would be very helpful if you do. I’ve
been trying to come up with my own spreadsheet and am having a hard time matching the results of
another program that has to be purchased. Any help you can provide would be great

Tom Do (http://www.enersul.com/) says:

May 21, 2016 at 3:14 am (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1144)


Hi, for Heat Loss From An Insulated Pipe spreadsheet, can you please let me know what the five cases
shown on the calculation sheet are? For the first case (cell G20), surface temperature is equal to Ambient
Temperature + 1. For the second case (cell H20), surface temperature equal to cell G56. and so on for the
other three cases. What do these 5 cases represent?

thank you.
Tom
https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/ 5/12
4/14/2018 Heat Loss from Insulated Pipe – ChE Guide

CheGuide says:

May 21, 2016 at 9:48 am (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1148)


Iteration is required to calculate surface temperature, as a first guess it is taken as ambient temperature +
1, later on it is recalculated in the calculation and used as initial value for next iteration. 5 cases represent
iteration with di erent surface temperatures. A er 5 iterations when there is no change in surface
temperature, it gives the final calculated value.

Tom Do (http://www.enersul.com/) says:

May 23, 2016 at 8:00 am (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1165)


much appreciated.

Regards
Tom

JUNG says:

June 21, 2016 at 4:57 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1484)


In case the pipe is buried in underground, how can I calculate the heat loss?
Do I just apply thermal conductivity of soil instead of air?
how can I assume heat transfer area for soil?
Please, give me your answer.

CheGuide says:

June 26, 2016 at 11:49 am (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1529)


Soil will act as insulating material and its thermal conductivity can be used for heat transfer calculation.

Xiaoqi says:

July 4, 2016 at 7:55 am (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1613)


Can I use this calculation sheet under the heat gain case with colder fluid in the pipe ?

Thank you

https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/ 6/12
4/14/2018 Heat Loss from Insulated Pipe – ChE Guide

CheGuide says:

July 9, 2016 at 12:58 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1639)


Same calculation can be used for colder fluid in pipe.

Xiaoqi says:

July 4, 2016 at 8:12 am (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1614)


I think the following equation maybe some mistake:

h_radiation = σ ε (t_average4 – t_ambient4)/ (t_average – t_ambient)

If ε is emissivity for cladded surface. Then I think the equation should be like this:

Aerogel Insulation Blanket


Price: USD 15/Square Meter
AdAerogel Blanket Is One Flagship
Product Of Our Company.Low Price, …
Joda - Aluminum Equipment

Learn more

h_radiation = σ ε (t_surface4 – t_ambient4)/ (t_surface4 – t_ambient)

In this equation, we calculate the radiation heat transferring between cladding surface and the ambient.

Do you agree with me ? @CheGuide

Thanks

CheGuide says:

July 9, 2016 at 1:40 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1641)


Thanks for finding the error in equation, we have corrected the formula and the attached spreadsheet.

BHUBESH CHANDRA says:

July 7, 2016 at 9:46 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1627)

https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/ 7/12
4/14/2018 Heat Loss from Insulated Pipe – ChE Guide

WHAT IS THE DENSITY OF MINERAL WOOL IN THE THE HEAT LOSS CALCULATOR? PLEASE DO REPLY.

CheGuide says:

July 9, 2016 at 1:08 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1640)


Mineral wool density is 430 kg/m3

BHUBESH CHANDRA says:

July 9, 2016 at 4:56 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1644)


Thank you so much for answering.
Sir, I want to calculate the heat loss at density 120 kg/cu. m and 150 kg/cu.m of the insulation material
and having pressure 3 kg/sq. cm. of oil.
So how can I do that?
can you please tell me the relation between density and heat transfer because it will be easy for me to
calculate.

CheGuide says:

July 11, 2016 at 10:02 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1662)


Heat transfer depends on thermal conductivity of insulation material and not on density. In above
equations density of insulation is not used.

BHUBESH CHANDRA says:

July 9, 2016 at 5:05 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1645)


sir can you please confirm it is 430 kg /cu. m.

CheGuide says:

July 11, 2016 at 10:04 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1663)


We have taken a sample insulation material available in the reference text book “Fundamentals of
Heat and Mass Transfer (2007), Frank P Incropera”. You need to find and consider properties of
insulation material being used.

BHUBESH CHANDRA says:

https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/ 8/12
4/14/2018 Heat Loss from Insulated Pipe – ChE Guide
July 9, 2016 at 5:14 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1646)
sir also clarify the unit of heat loss BTU/h/ used in the calculator…that it BTU/h/ or BTU/h/ sq.

CheGuide says:

July 11, 2016 at 10:07 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1664)


Calculator gives heat loss per unit length of pipe.

BHUBESH CHANDRA says:

July 12, 2016 at 10:50 am (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1669)


Thank you so much for answering my questions and sharing your knowledge.

Mechanical Engineer says:

August 1, 2016 at 11:36 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1843)


This spreadsheet is nicely done. I like the curve fitting.
1) This spreadsheet will work for compressible fluid (air) in the pipe. Correct? (Perhaps adding the
convective thermal resistance on the inside of the pipe would be wise in that case).
2) It appears that k_pipe cells G88:K88 are missing the ^4 term from the Properties tab, although the
number appears to be negligible. Please confirm that the ^4 term should be added.
3) What is the purpose of cells G19:K20? I20:K:30 say NA. None of these appear to be used by other cells. The
same question applies ot the 2nd & 3rd rows of curve fitting coe icients on the Air_Properties sheet.
4) I suggest adding a short note near the 1st instance, indicating that the “.” in your equations indicates
multiplication. For instance, it would help people to easily understand ” r_pipe = D3.ln(D2/D1) / 2.k_pipe”.
It’s easy enough to figure out when you already know what the equation would look like, but for those who
don’t…

Mechanical Engineer says:

August 1, 2016 at 11:46 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-1844)


Please ignore question 2 above. I see that the insulation and air properties use a 4th order polynomial fit,
but the pipe uses a 3rd order fit. Adding a ^4 term is not needed.

https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/ 9/12
4/14/2018 Heat Loss from Insulated Pipe – ChE Guide

Dennis Frijsinger says:

August 31, 2016 at 3:08 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-2225)


In the second and consequtive iteration the surface temperature of the bare pipe is taken from the
calculated interface temperature.

Is it not better to calculate this in each iteration using:


Interface Temp – Heat Flow x Insulation Resistance

Humberto says:

March 23, 2017 at 8:42 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-4862)


Hello

Heat Losses di er a little bit from the Website counterpart. Is it due to the Wind Speed? If so, is there a
standard wind speed you use for the website calcs?

Thanks!

A says:

April 11, 2017 at 5:01 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-5052)


Hi! U is di erent from Temperature di erence over resistance.
If I’m not wrong – there should be a 1/2pi factor to the overall resistance formula.

Andrew says:

April 26, 2017 at 9:13 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-5119)


Thanks for the calc. It’s very useful. What should I do to change the insulation material? Thanks,

CheGuide says:

April 26, 2017 at 9:45 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-5121)


Thermal conductivity of insulation material needs to be changed in properties sheet to use di erent
insulation material.

https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/ 10/12
4/14/2018 Heat Loss from Insulated Pipe – ChE Guide

Bernardo says:

July 24, 2017 at 7:43 am (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-5385)


Hi, your article is excellent. I would only add that instead of iteration, you can run a solver in Excel to match
t surface estimated with t surface calculated.
One question: how to take into account the solar radiation in your formulas? Thank you!

Sharan says:

July 31, 2017 at 12:20 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-5408)


Can you please check the calculation of Rayleigh Number? This formula looks di erent from ASTM C680.
For some reason I could not paste the formula from ASTM C680.
Can you also share the calculation for Flat Surfaces anf Vertical Pipes?

Sharan says:

July 31, 2017 at 12:25 pm (https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/#comment-5409)


Can you please also suggest what is the di erence between Kinematic Viscosity (ν) and Alpha Curve (α)?
Formula for Rayleigh is linked to α instead of Thermal Conductivity (k)?

https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/ 11/12
4/14/2018 Heat Loss from Insulated Pipe – ChE Guide

Leave a Reply
Your email address will not be published. Required fields are marked *

Comment

Name *

Email *

Website

Post Comment

https://cheguide.com/2015/12/heat-loss-from-insulated-pipe/ 12/12

Das könnte Ihnen auch gefallen