KEYPLAN GENERAL NOTES DRAWING REGISTRY 1. FOR ALL AIR-CONDITIONING SERVICES, ALL
VOLUME DAMPERS SETTING AT STUB-OUT
SHALL BE PERMANENT/FINAL UPON
ME-LOD-FF026-00 CAFE UNIT FF-026 COVER PAGE COMPLETION OF BALANCING WORKS.
· ALL DIMENSIONS ARE IN MILLIMETERS
16 21 27 33 39 45 51 57 64 69 · DIMENSIONS ARE ONLY INDICATIVE AND MAY CHANGE DUE TO SITE CONDITIONS ME-LOD-FF026-01 CAFE UNIT FF-026 FLOOR PLAN MEPF LAYOUT TENANT/TENANT CONTRACTOR IS
13 19 24 30 36 42 48 54 60 66 72 · TENANT / TENANT CONTRACTOR TO VERIFY DIMENSION ON SITE PROHIBITED IN ADJUSTING/MODIFY THE
· TENANT OF F&B UNIT WHICH DOES NOT HAVE A DESIGNATED SERVICE ACCESS SETTING WITHOUT PROPER
C TO COMPLY WITH AUTHORITY'S REQUIREMENT TO PROVIDE A REFRIGERATED BIN AUTHORIZATION FROM THE LANDLORD.
F HOLDING SPACE WITHIN THE PREMISE. TENANT TO UTILISE THE EXISTING FLOOR 2. DUCTED RETURN SYSTEM SHALL BE USED
H TRAPS AND PROVIDE NECESSARY WATER-PROOFING AND INSULATION FOR TENANT FAN COIL UNITS. TENANT
L · TENANCY LEASE PLAN FOR THE MEP WORKS ARE DIAGRAMMATIC AND ARE SHOULD EXTEND THE RETURN AIR &
P INTENDED TO CONVEY GENERAL ARRANGEMENT ONLY, TENANT / TENANT EXHAUST AIR STUB-OUT BELOW FALSE
CONTRACTOR SHALL VERIFY THE ACTUAL POSITION OR LOCATION OF MEP CEILING IF FALSE CEILING IS PROVIDED
S WITHIN THEIR RETAIL UNIT.
SERVICES ON SITE, PRIOR TO TENANCY FIT-OUT WORKS.
V · LOCATION OR POSITION OF SERVICES MAY CHANGE DUE TO ACTUAL SITE 3. ALL EQUIPMENT, PIPING, DUCTWORK ETC.,
Y CONDITIONS. SHALL BE SUPPORTED AS DETAILED,
SPECIFIED AND REQUIRED.
CC 4. INSTALL ALL MEP EQUIPMENT AND
FF APPURTENANCES IN ACCORDANCE WITH
LANDLORD MANUFACTURER’S RECOMMENDATIONS,
JJ MECHANICAL SERVICES REMARKS CONTRACT DOCUMENTS AND APPLICABLE
PROVISION
NN CODES AND STANDARDS.
· CHILLED WATER SUPPLY AND RETURN YES DIAMETER: 50mm 1.26 L/s FLOWRATE 5. FOR COLD WATER SUPPLY , TENANT IS
PIPES COMPLETE WITH ISOLATING VALVES. ALLOWED TO CONNECT TO ONLY ONE
FF-026 WHEN MULTIPLE STUB-OUTS ARE
N · CONDENSATE DRAIN PIPE NO PROVIDED INSIDE THE UNIT.
FIRST FLOOR 6. AS PER THE DISTRICT COOLING PROVIDER,
· RETURN AIR DUCT TEE-OFF NO
CHILLED WATER SUPPLY TEMPERATURE =
· EXHAUST AIR DUCT TEE-OFF YES DUCT SIZE: 300x200mm 185 L/s FLOWRATE 6.5°C. CHILLED WATER RETURN
UNIT LOCATION
A
BL
TEMPERATURE = 16°C.
· SMOKE CONTROL EXHAUST AIR DUCT NO
QI
SOCKET OUTLET SP SOIL PIPE · CONTAINMENT FOR GSM SYSTEM-(CABLES & ANTENNAS EXCLUDED) YES
CT CABLE TRAY BCWS BOOSTER COLD WATER SUPPLY · SMOKE DETECTORS YES
SAD SUPPLY AIR DUCT FIRE PROTECTION · VALVE STUB OUT FOR STAND PIPE AND FHR NO
EAD EXHAUST AIR DUCT ZCV ZONE CONTROL VALVE PLUMBING SERVICES
FAD FRESH AIR DUCT · COLD WATER SUPPLY PIPE COMPLETE WITH ISOLATING VALVE YES DIAMETER: 32mm
FP FIRE PROTECTION
KED KITCHEN EXTRACT DUCT WRS WET RISER STAND PIPE DRAINAGE SERVICES
BTU BTU METER UPRIGHT SPRINKLER HEAD · WASTE AND VP PROVISIONS. YES FOR NUMBER AND LOCATION OF STUB OUTS REFER TO DRAWINGS
CHWF&R CHILLED WATER FLOW & RETURN SUPERVISION VALVE ALL CDP TO BE CONNECTED TO WASTE PIPE WITH TRAP.
FD FIRE DAMPER
D2
FIRST ISSUE
SECOND ISSUE
26/10/17
30/11/17
DUBAI HILLS MALL DRAWN CHECKED APPROVED
NTS.
DRAWING NO.
ME-LOD-FF026-00
SHEET NO
1/2
REV NO
D4