CAESAR II 2013 R1 Ver.6.10.00.

0030, (Build 130Date:APR 18,2013 @12:17 Pg: 1


Job: C:\Documents and Settings\Administrador\Mis documentos\CURSO CAESAR\BOMBA B.610
Licensed To: MODELOSOFT - TRAINING LICENSE ID 22140
CAESAR II ANALYSIS REPORT: API 610 2004 - Centrifugal Pumps (10th Ed.)

Description:
BOMBA BE
CONFORME AL APENDICE F

INPUT (CAESAR II Global Coordinates):

Horizontal Pump
Pump axis direction cosines (X,Z): ( 1.000, 0.000)

Node # Orientation Nominal Diameter


Suction Nozzle 420 End 3
Discharge Nozzle 1 End 0

Table 4 Allowable ( ratio ) = 2.00

Suction Nozzle Discharge Nozzle

X Distance = 4.0 in. 0.0 in.


Y Distance = 0.0 in. 0.0 in.
Z Distance = 0.0 in. 0.0 in.

X Force = 65.0 lb. 0.0 lb.


Y Force = -166.0 lb. 0.0 lb.
Z Force = -255.0 lb. 0.0 lb.

X Moment = -396.0 ft.lb. 0.0 ft.lb.


Y Moment = -937.0 ft.lb. 0.0 ft.lb.
Z Moment = 199.0 ft.lb. 0.0 ft.lb.

OUTPUT (API 610 10th Edition Local Coordinates)

Suction Table 4 Force & Moment Status


Values Ratios
x distance = 4.0 in.
y distance = 0.0 in.
z distance = 0.0 in.

x force = 65.0 lb. 300 0.22 Passed


y force = 255.0 lb. 240 1.06 Passed
z force = -166.0 lb. 200 0.83 Passed

x moment = -396.0 ft.lb. 700 0.57 Passed


y moment = -199.0 ft.lb. 350 0.57 Passed
z moment = -937.0 ft.lb. 530 1.77 Passed

Check of Condition F.1.2.b Requirement Status

(FRSa/1.5FRSt4) + (MRSa/1.5MRSt4) = 1.210 < or = 2.00 Passed


(FRDa/1.5FRDt4) + (MRDa/1.5MRDt4) = 0.000 < or = 2.00 Passed

Check of Condition F.1.2.c Requirement Status

1.5 ( FRSt4 + FRDt4 ) = 645. > 311. (FRCa) Passed


2.0 ( MYSt4 + MYDt4 ) = 700. > 144. (MYCa) Passed
CAESAR II 2013 R1 Ver.6.10.00.0030, (Build 130Date:APR 18,2013 @12:17 Pg: 2
Job: C:\Documents and Settings\Administrador\Mis documentos\CURSO CAESAR\BOMBA B.610
Licensed To: MODELOSOFT - TRAINING LICENSE ID 22140
CAESAR II ANALYSIS REPORT: API 610 2004 - Centrifugal Pumps (10th Ed.)

1.5 ( MRSt4 + MRDt4 ) = 1425. > 950. (MRCa) Passed

Overall Pump Status ** PASSED **