Sie sind auf Seite 1von 12

Intégrateur global System-MED. Photo copyright Hervé Champollion 2016.

Hospital Systems

Operating theatres
Care services
Central sterilizations
Analysis laboratories
DAGARD,
Experts in GMP Cleanrooms Envelops

For more than 60 years, Dagard has been designing, manufacturing and installing modular
insulated solu ons all over the world.

DAGARD Cleanroom division has 30 years of exper se in GMP modular cleanroom envelops,
in many applica ons.

Hospitals adhere to the highest standards with strict, stringent requirements and as such
are considered cleanrooms of a different class.

Dagard Cleanroom offers best-in-class envelop’s solu ons such as par ons, ceilings, doors,
glazing and accessories, in accordance to the project from research laboratories to product
manufactures.

Flexible, Adaptable, Cleanable, Sustainable

2
Tailor-made modular systems

ParƟƟons for operaƟng theatres

• “Bi-bloc” (bi-panel) technical walls


• Sliding doors

ParƟƟons for rooms with reinforced hygiene

• “Monobloc” walls with removable panels


• Service and sliding doors
• Glazing

Tight ceilings

• “Walkable” ceilings
• “Non walkable” ceilings

Technical details

• Various integra ons


• Addi onal elements

3
“Bi-Bloc” (bi-panel) technical parƟƟons

Walls system allowing an easy and adaptable integra on of


all technical services, consis ng of:

• Hidden studs frame, single or double side with adjustable


thickness,

• Removable facings: metallic, HPL ... skins


or fixed facings : resin or glass.

For independent removable claddings, 2 types of seals are


available :

• Screwed facings with an bacterial polymer push-in


gaskets, removable and washable,

• Clipped metallic facings or HPL facings fixed by strip, with


silicone caulk for the ghtness.

Op onal filling:
• BA13 RX for radiology rooms,
• Specific components for acous c performances.

▪ Non progressive installation


▪ Easy and quick to install
▪ Fully flushed surfaces
▪ Demountable, movable and flexible
▪ Integrated networks

4
ParƟƟons for operaƟng theatres
(resuscitaƟon, intensive care ...)

Metal claddings

Galvanised steel or 304 or 316 stainless steel, lacquered or


coated with:
Polyester lacquer, PET complex, PVC film, an bacterial PVC
film, PVC + PET film.

Facings with syntheƟc resin

Solid mineral surface with welded joints totally ght (non


removable facings).

HPL facings

Non flammable high pressure laminated (HPL).

Doors, Glazing and Equipment

• Leaded sliding doors


• Service doors
• Double flush glazing
• Leaded glazing
• Air extract ducts
• Integrated equipment

5
Monobloc walls with removable panels

Peripheral walls or par ons consis ng in modular


sandwiches panels, thickness 60 mm:
• Choice of skins : HPL or metallic, galvanized steel or
stainless steel, various finishes,
• High density mineral wool core or PUR/PIR foam core.
Progressive or non progressive installa on, totally flush
finishing.
Tightness with extruded mas c.

Easy to clean and Ɵght doors

• Tight sliding doors


• Single or double flush hinged doors
• Many op ons and finishing
• Variants with reinforced ghtness or with inflatable seal

Management kits

Complete line of signalling, control and interlocking


accessories to manage the airlocks.

6
ParƟƟons for reinforced hygiene rooms (sterilizaƟon,
laboratories, laundry, pharmacy ...)

Double flush glazing

Laminated double glazing thickness 60 mm assembled in


factory.
Op onal : manual or automa c integrated blinds.

Mullions, electrical raceways

Specific “duct” profiles width 100 mm with removable cover


allowing the passage of fluids, the s ffening of glazed areas
or the realiza on of easy to dismantle zones.
Totally flush and ght elements.

Specific products

Air extract ducts,


Fire hose cabinets,
Access hatches,
Emergency exit - self breaking glasses ... .

7
Ceilings with sandwich panels

“Walkable” ceilings, made of the same panels as the wall’s


panels, thickness 60 mm.
Flush junc ons.
Authorized punctual load = 150 daN.

Modular ceilings on steel frame


“Walkable” ceiling made of heavy duty steel frame and infill
panels of thickness 60 or 80 mm.
This “technical pla orm” allows an installa on in parallel at
floor level and in the plenum.
Admissible uniformed load = 250 daN/m².

Modular ceilings on aluminium grid

“Walkable” ceilings, made of aluminium profiles and infill


panels.

“Bi-bloc” or “casseƩe” ceilings

Ceiling with suppor ng linear metallic profiles of sec on


100 mm, very sturdy.
Admissible uniformed load = 250 daN/m².
Infill casse es with two parts (lower and upper) which allow
the hidden, ght and evolving incorpora on of all electrical
services (light fi ngs, cables, ...) and also HVAC terminals.

8
Tight ceilings

“Non-walkable” ceilings

Ceiling made of a linear structure and non-walkable ght


casse es.
The access for installa on and maintenance is made from
the inside of the room.

Recessed light fiƫngs

Wide line of flush and ght light fi ngs with lamps or LED.
Maintenance either from above or below.
Many op ons (dimmable light, backup ba ery ...).

HVAC terminals integraƟon

Installa on with profiles or with lined cutouts for a ght


and flush integra on of supply or return air outlets, par cle
filter units ... .

9
Specific technical panels

To recess and distribute medical fluids, electrical outlets or various control accessories.

Boxes Horizontal channels Raceways

Customized panels Passages of fluids Outlets, switches

Screens, control panels Film viewers Clocks

10
Intégrateur global System-MED. Photo copyright Hervé Champollion 2016.
Technical details

Totally glazed parƟƟons

Single glass ght par ons allowing the separa on between


ultra clean areas while offering a total visibility.

Finishing accessories

Wide choice of finishing or protec on accessories.


Skir ng, coving sec ons, handrails, angle protec ons,
kick plate protec ons, ... enhance the longevity of walls.

Pass-throughs

Customized produc on of various pass-throughs.


Different op ons: dimensions, materials, interlocks ... .

Decors, Glass artworks

Possibility to customize the walls with decora ve PVC plates


or glazed par ons.

11
They trust us
THE OTTAWA HOSPITAL USA, PALAIS ROYAL MOROCCO, AUSTIN HOSPITAL AUSTRALIA,
HOSPITAL LARIBOISIERE FRANCE, HOSPITAL SAINT AUGUSTIN FRANCE, HOSPITAL CENTRE

DSP-0002-E/A June 2016. Document non-contractual. Dagard reserves the right to modify its products without prior no ce.
LAPEYRONNIE FRANCE, HOSPITAL CENTRE BREST FRANCE, IMMUNOTHERAPY CENTRE
INSERM FRANCE, HOSPITAL EL BASSATINE TUNISIA, ISTITUTO NAZIONALE DEI TUMORI ITALY

Route du stade - 23600 BOUSSAC - France


Phone : +33(0).555.824.000 - info@dagard.com

www.dagard.com

Das könnte Ihnen auch gefallen