Sie sind auf Seite 1von 26

(IS 3043:1987 - Code of Prac ce for Earthing)

REMEDIES LIGHTNING PROTECTION FOR SOLAR PLANT


R

ABOUT US

We REMEDIES EARTHING SYSTEMS PVT. LTD, entered the earthing & lightning industry in the early part
of the 2005’s much before the technological revolu on took place. In 10 years, a er dealing earthing &
copper bonded rod of all types and sizes, we realized that the en re industry’s success and failure fell in
the hands of an Lightning system.
We are Authorized distributor of PROTART ELEKTRIK BILISIM TEKNOLOJILERI DIS TIC. A.S from Turkey,
PROTART is a manufacturer of ESE Lightning conductor his device is one of the best ESE lightning device
in the world.

In REMEDIES EARTHING SYSTEMS PVT. LTD, we are experts in lightning protec on. We have at your
disposal all the exis ng technology and innovate every day, giving suitable solu ons to each par cular
case. We manufacture our products according to maximum quality standards. Research, innova on
and safety are the key factor underlining our leadership and presence the world over.

RESPL not only provides these services for Railways, Telecom, Power Companies, Ins tu ons, Hospitals,
Sewage Treatment plants, Pump Sta ons, and other process industries but also for dwelling units, thereby
increasing the safety by combining high-quality services with latest technology.

RESPL provides Safety with Quality by understanding customer requirements & implemen ng their
thoughts into ac on. We assure and ensure special a en on to comprehend the complexi es of the
customer objec ves

process, priori es and their expecta ons. This helps us to provide solu on in a befi ng manner to reach
the utmost customer sa sfac on

MISSION AND VISION


Our goal as a company is to provide safe and technologically advanced solu ons within the area of lightning
protec on. Our aim is to be the technological reference in this field, providing the most complete range of
products and solu ons.

Remedies Earthing Systems Pvt. Ltd. Is the leading manufacturer of unique earthing with brand
name of “ERIC” Maintenance Free Earthing Electrode with exclusive Pipe in Pipe & Strip in Pipe
Technology.
R

SERVICES
REMEDIES EARTHING SYSTEMS offers you a whole team of specialists to facilitate all the following services:
Studies and projects: risk of lightning strike analysis, regulatory compliance, reports, diagrams and
quota ons. Technical assessment: Technical team for evalua ng the most suitable solu on for each case.
Verifica on and maintenance: inspec on of the lightning protec on installa ons according to the standards
and adjustment /maintenance of them. Installa on: groups of installers and specialists in ver cal works for
carrying out the installa ons.

IMPORTANCE OF EARTHING

Earthing and grounding is the most important component in an electrical circuit. It is necessary to eliminate
electrosta c discharge which can destroy sensi ve equipment and disturb power supply. The primary
objec ve of earthing is to control radio frequency emission and electro magne c interference to provide
stable reference poten al for instrument to provide a safe discharge path for short circuit and ligh ng
currents.

Apart from human safety, costly and sensi ve electronic equipment are vulnerable even to small fault
currents which seriously affect the life and performance of the equipments.
R

Over the years, billions of dollars worth of property has been destroyed due to electrical failures, short
circuits etc causing fires, electrocu ons and other mishaps. But more importantly, lives were lost.

This makes earthing of crucial importance everywhere electricity is used.

A complete lightning protec on & earthing system cons tutes the following:

a. Safe Earthing Electrode


b. Back Fill Compound
c. Lightning Arrester

A Good Earthing system

for Power Quality Assurance of your equipment


Improved System Performance
– Reduced ambient noise levels
– Less system down me
– Fewer equipment failures
– Increased equipment life
R

THE EARTHING SYSTEM


Remedies Safe Earthing Electrode
It is a metal electrode which goes into the
ground near the building. It helps in the efficient
discharge of all the fault currents/ surge
currents present in the electrical system. It also
helps in dissipang the high voltages which are
passed on through the lightning arrestors atop
buildings.

Factors affecting Earth Resistance

1. Resistance of the electrode .


2. Contact Resistance between the electrode and the soil
3. Resistance of the soil from the electrode surface outward

Safe Earthing
Equipment Earth

Poor Earthing
R

COST EFFECTIVE SOLUTIONS TO YOUR LIGHTNING


PROTECTION & MAINTENANCE FREE EARTHING NEED

Did You Know


Lightning can hit anything on the ground. Even
a person standing on the ground next to the
Empire State Building. The most common
misconcep on is that lightning strikes only the
tallest of structures.
R

Grounding / Earthing
Good earthings of Lightning Protec on Systems shall be able to withstand lightning currents
and to disperse them quick and safely.

A Well designed, low impedance and an


effec ve grounding/ earthing system is
basic requirement of any electrical
installa on and it is quite essen al that the
same should work propely as it forms a
primary line of protec on for the
equipment and the operator from the
damaging effects of fault current.

The wide range of grounding solu on s available with us are


giving below.

Earthing Electrode Copper Bonded Rod


Copper Bonded Strip Earth Enhancing Compound
Super Earthing Kit Solar Earthing Kit
Mobile earthing Earthing Accessories

We are one stop solu on providers in manufacturing world class


Earthing Electrodes which offer superior quality grounding/
earthing systems. The grounding electrodes provide a low
ground resistance and impedance and is capable of withstanding
higher fault current. Our maintenance free and safe earthing
electrodes are available in variety of designs and specifica ons
so as to be able to meet the client’s requirements.
Our wide range of earthing electrodes include

Copper Bonded Electrode Copper Electrodes GI Electrode

Safe Earthing Electrodes

• Hot Dip Galvanized Electrodes


• Zinc Coated Electrodes
•Copper Bonded Electrodes
•Copper Bonded Rods
• Copper Bonded Electroly c Electrode
• Hot Dip Galvanized Electroly c Electrode
Copper earthing electrode
R

As per the variegated requirements of our clients, we are


(Warranty 25 YEARS)
offering a broad collec on of Copper Bonded Electrode. The
offered copper bonded Electrode is integrated in our working
unit by u lizing best quality of material with the aid of
innova ve technology. In addi on to this, our customers can
benefit this copper bonded Electrode with customiza on
facility on the special demand of customers at reasonable
rates.

RESPL CP | Copper Plated

Copper coa ng thickness of 50 - 250 + microns


as per UL Standards

Very high electrical conduc vity


ante - corrosion proper es

Long service life

Best suited for harsh environments

Other Details:

It is long-las ng and free of maintenance hazards


Unique manufacturing process ensures uniform
coa ng thickness
It is easy to install and is unbreakable
Corrosion free while providing the lowest resistance
to ground
Very economical to use
R

Copper Bonded Rods

High tensile low carbon steel


• Complies BS 4360 grade 43A
• 6’ – 10’ long X ½” - ¾” dia
• Molecularly bonded with 99.9% copper
• Coa ng thickness - 10 mil ( 254 microns)
• UL listed Rods
• CPRI + tested – 23 kA for 1 second
• Meets IS:3043 -1987 # standard
• Service Life - 40 years in most soil types
R

“ERIC” Earth Enhancing Compound

Highly Conduc ve cemen ous compound


• More surface area
• Homogeneous and stable
• Doesn't leach into the ground
• Enhances the life of copper bonding
• Environmentally Friendly
• Low Resis vity
• Suitable for all terrain
• Can be used in dry or slurry form
• Permanent and Maintenance Free
R

A phenomenon discharging atmospheric charges

 Negative electrical charges build up


within clouds
 Electric eld intensication
 Positive charges gather on ground
 Air breakdown leads to stepped
leader
 Further electric eld intensication
 Strong upward positive streamer
generation
 Positive upward streamer meets the
downward step leader
 Conducting path forms
 Visible lightning ash

What is lightning ?

Lightning Current - 200 A - 200 kA

Temperature - Can generate upto 54,000o F

Frequency - 100 cloud to earth lightning events

every second around the world

• Cloud to Cloud

• Intra Cloud

• Cloud to Earth
R

Structural Lightning Protection

Franklin
Rods

ESE Lightning Protection

Advance Lightning

Protection Radius, Rp
R

PROTART-60 ESE LIGHTNING CONDUCTOR

PROTART-60 ESE LIGHTNING CONDUCTOR is manufactured


from high quality stainless steel which makes it durable
against the toughest weather condi ons.

When there is change in the electro magne c field in the


atmosphere, the ion generator inside the PROTART-60 ESE
terminal begins to release posi ve ions in to the atmosphere
which a racts the lightning emissions on to the ESE rod.
Standard product does not come with an adaptor. The
adaptor rod has 30mm diameter with a 25mm internal
diameter but we are able to manufacture rod adaptors to the
customers requirement. Our product is cer fied from Middle
Eastern Technical University in NFC 17.102 Annex C. You are
able to find all the dimensional informa on regarding
PROTART-60 ESE inside the relevant NFC 17.102 test report.

Model: PRO- 60
Type: E.S.E. Lightning Rod
(Early Streamer Emission)

ΔT: 60 µs (NFC 17 102)


ΔT (real): 72 µs (tested)
Material: Stainless Steel
Height: 37x22x12
weight: 2.32 kg
R

PROTART-30 ESE LIGHTNING CONDUCTOR

PROTART-30 ESE LIGHTNING CONDUCTOR is manufactured


from high quality stainless steel which makes it durable
against the toughest weather condi ons.

When there is change in the electro magne c field in the


atmosphere, the ion generator inside the PROTART-30 ESE
terminal begins to release posi ve ions in to the
atmosphere which a racts the lightning emissions on to
the ESE rod. PROTART-30 ESE rod is a unique product in a
sense that it’s measured Δ T is 57 μs which is also making
it suitable for the requirements for an ESE rod with a Δ T:
45 μs proving a wide coverage.

Model: PRO- 30
Type: E.S.E. Lightning Rod
(Early Streamer Emission)

ΔT: 30 µs (NFC 17 102)


ΔT (real): 57 µs (tested)
Material: Stainless Steel
Height: 37x22x12
weight: 1.98 kg
R

PRO LIGHTNING STRIKE COUNTER

With PRO TESTER, you are able to determine if there is a


short circuit or a fault in the ion generator immediately
by simply screwing in the special plug at the end of the
cable to the ESE rod and pressing the bu on on the
tes ng device. We are able to make the cable on the
tes ng device according to the customer’s requirements.

PRO TESTER

With PRO TESTER, you are able to determine if there is a short circuit
or a fault in the ion generator immediately by simply screwing in the
special plug at the end of the cable to the ESE rod and pressing the
bu on on the tes ng device. We are able to make the cable on the
tes ng device according to the customer’s requirements.
R

SAMPLE OF INSTALLATION ESE LIGHTNING CONDUCTOR


R

SAMPLE OF INSTALLATION ESE LIGHTNING CONDUCTOR


R

REMEDIES CONVENTIONAL LIGHTNING ARRESTER


COST EFFECTIVE SOLUTIONS TO YOUR LIGHTNING
PROTECTION & MAINTENANCE FREE EARTHING NEED
Conven onal Lightning Protec on Systems offers high
protec on shield to buildings, structures, equipment and
person. When lightning strikes, it will preferen ally strike the
spike arrester, and be conducted harmlessly to ground
through the wire, instead of passing through the building,
where it could start a fire or cause electrocu on.

REMEDIES upholds exper se in developing & delivering


Conven onal Lightning Protec on system as per IS - 2309 and IEC-
62305. The working mechanism of lightning Protec on system is
given below.

AIR TERMINATION The air termina on rods are available in


Copper, GI , Aluminum or copper bonded
RODS which divert lightning spikes to ground. The
rods are mounted on top of the building for
catching the discharge of lightning current
from the cloud and safely divert the same to
the ground without damaging the structure.

Remedies have manufacturing four type of lightning Rod.


1. Aluminum Lightning Rod 2. GI Lightning Rod 3. Copper Lightning
Rod 4. Copper bonded lightning Rod

Air termina on and down conductor


systems.
From the air termina on devices on
the roof, arrestors on in the building
walls carry the lightning current
safely from the point of impact down
to the earthing system.
R

REMEDIES PIT COVER


Applica ons :-
Environment Friendly
Heavy duty and weather proof
Green top cap matches the environment
Made of heavy duty polyethylene for extra durability

Specifica ons:

At Top: 10 inches (254 mm)


At Bo om: 13 inches (330 mm)
Height 10.25 inches (260mm)

Applica ons:

Agricultural
Industrial
Commercial
Ins tu onal
Residen al

REMEDIES PIT COVER


R

PROTART ESE CERTIFICATE


R

Earthing Test Report


R

ERIC Backll Compound Test Report

Remedies Company Certicate


R

REMEDIES CLIENT
R

Thank You
For Choosing Remedies…
For further information please contact:

Mr. Siraj Ahmad


Managing Director
Remedies Earthing Systems Pvt. Ltd.
Mob : +91- 9936 47 6665, 9198 9898 99
Tel : +91- 0522 4047046
info@remediessystems.com
seraj@remediessystems.com
shahnawaz@remediessystems.com
sirajrespl@gmail.com

Das könnte Ihnen auch gefallen