§§ Issue
Issue :: No
No Video
Video
§§ Model
Model :: LM201U05-SLL1
LM201U05-SLL1
Customer ::
§§ Customer Dell
Dell // Qisda
Qisda
§§ Date
Date :: Sep.
Sep. 2,
2, 2008
2008
■ General
• Detailed information for this issue.
■ Phenomenon
No video phenomenon occurred at MVT
-. B/L on but No display
Timing controller IC
open
Pvcom IC
open
EEPROM
open
▣ This test is to verify the abnormal component in Vcc section.
▣ After cutting the each part of the line to find the defect component, open & short test was done with GND.
▣ Through the test, we found that ESD diode got defected.
Vcc(3.3V)
T-con EEPROM
ESD diode
▣ Burning ESD diode can take place with high voltage stress.
-. #1 ESD diode is connected to Vcc, SCL & SDA.
-. Vcc=SCL=SDA=3.3V
-. Short between pin#4 & #5 by inserting wrongly or metallic particle could be the
situation that makes this issue.
※ SCL & SDA is the line to make a write ODC data and to adjust the Vcom.
Removing the
defect Diode
Normal
Display
< Remove the defected diode > < Screen Display >
3. Conclusion
1) No video phenomenon happened because the ESD diode burning.
2) This S/N 20187N8670109 sample passed LGD internal inspection & OBA
3) LGD assembled MVT sample at Nanjing MP line. This kind of the defect is obviously detected on the first
step of quality assurance process.
4) Thus, it is assumed that the short between pin #4 & pin #5 happened because of metallic foreign materials inflows
5) Actually. this connector has been used for LM190E08 and LM190WX1 series model from Mar. of this year,
there`s no this kind of issue happened
6) LGD regards this is not a reliability problem but handling issue and will not happen in MP process
Vin(18~19V)
Vin(18~19V)
Damage Damage
GND
VCC
GND
VCC
Diode Diode
Pin5 : SCL
Pin5 : SCL
Short
Pin4 & Pin5
Metallic Particle
Short
#7 #6 #5 #4 #3 #2 #1 #7 #6 #5 #4 #3 #2 #1
Main.&Rep. Execution
3. Implementing Mini Super Cleaning
Cleaning Execution
4. List up on Process Improvement & newly found items
Item