Proposed Project Page:

Address of Project Project No.: 15-0001


Architect Designed: b
Pad Footing PF17
PAD FOOTING V5.01 Demo User

Pad: (Pad Footing PF17) 2600mm long x 1000mm wide, 600mm deep OK (0.99)
f'c = 25MPa, Bearing = 215kPa < 250kPa OK (0.86)
Reinf't: N20-200 cts (BLL), N20-200 cts (BUL) (BLL bars in L dir.) , 60mm cover
Column: 300mm long x 600mm wide, P* = 761kN

Geometry

Concrete strength (f'c) = 25 MPa Column length (CL) = 300 mm


Column width (CW) = 600 mm
Pad length (L) = 2600 mm Column area reduction = 0.94 m²
Pad width (W) = 1000 mm
Pad depth (D) = 600 mm Outstand in L direction = 1150 mm
Outstand in W direction = 200 mm
Method = E (E)lastic/(P)lastic Pad Area = 2.60 m²
Loading

Dead load (Pdl) = 250 kN (Excluding footing S.Wt)


Live load (Pll) = 300 kN

Eccentricity (EccL) = 0 mm
Eccentricity (EccW) = 0 mm

S.Wt. density (ρ) = 6.0 kN/m³


S.Wt. = ρ*L*W*D = 9.4 kN
P* = 1.2*(Pdl+SWt) + 1.5*Pll = 761 kN

Allowable bearing pressure = 250 kPa OK (0.86)


Max. bearing pressure (Bp) = 215 kPa Ultimate B.P.(Bp*) = 293 kPa
(Bearing elastically determined)
Reinforcement

Unreinforced = N (Y)es, (N)o


Extreme bottom bars in = L (W), (L) dir No. Reinf't layers = 1
Cover to bottom layer of reinf't = 60 mm Ductility class = A (N)ormal,(L)ow,(A)uto
Reinf't ductility class = N (N)ormal,(L)ow
BLL (in L dir.) = N20-200 cts (BLL) BUL (in W dir.) = N20-200 cts (BUL)
Bar size = 20 mm Bar size = 20 mm
Bar cts/No. per m = 200 mm Bar cts/No. per m = 200 mm
Steel Strength (fsy) = 500 MPa Steel Strength (fsy) = 500 MPa
Area steel (Ast) = 1571 mm²/m Area steel (Ast) = 1571 mm²/m
Depth to steel (ds) = 530 mm Depth to steel (ds) = 510 mm
Ast.min = 0.19*(D/ds)²*f'ct.f/fsy*ds = 774 mm²/m Ast.min = 805 mm²/m

Design capacities

Bending - Cl 8.1 & Cl 15.4.2 alpha (α2 = 1.00-0.003*f'c) = 0.850 (0.67 ≤ α2 ≤ 0.85) Eq 8.1.3(1)
gamma (γ = 1.05-0.007*f'c) = 0.850 (0.67 ≤ γ ≤ 0.85) Eq 8.1.3(2)
ø = 1.19-13*kuo/12 = 0.800 (0.60 ≤ ø ≤ 0.80) Table 2.2.2 for N Class
Moment (ML*) = 193.6 kNm/m øMuo.L = 321.4 kNm/m OK (0.60)
Moment (MW*) = 5.9 kNm/m øMuo.W = 308.8 kNm/m OK (0.02)
Plain concrete ø = 0.6 Table 2.2.2
øMuo.ur = 90.8 kNm/m
One-way shear - Cl 8.2 & Cl 15.4.3 fcv = f'c¹′³ ≤ 4MPa = 2.92 MPa
1-way shear (VL*) = 181.5 kN/m øVu.L = 183.4 kN/m OK (0.99) - Refer Cl 8.2.5(ii)
1-way shear (VW*) = 0.0 kN/m øVu.W = 182.1 kN/m OK (0.00)
β1.L = 1.177 β1.W = 1.199 øVu.ur = 144.7 kN/m

Punching shear - Cl 9.2 & Cl 15.4.3 Shear Perimeter (u) = 3840 mm


Pad load (P*) = 761 kN βh = 2.0 Cl 9.2.1.5
Column load reduction = 275 kN fcv = 1.70 MPa Cl 9.2.3
Punching shear (Vp*) = 487 kN øVp = 2330.5 kN OK (0.21)
øVp.ur = 1267.2 kN
Notes:

Reinforced Unreinforced
Moment L OK (0.60) No Good (2.13)
Moment W OK (0.02) OK (0.06)
Shear L OK (0.99) No Good (1.25)
Shear W OK (0.00) OK (0.00)
Punching OK (0.21) OK (0.38)
Bearing OK (0.86) OK (0.86)

Column area:
Column area calculated at the level of the bottom
tensile steel for reduction in punching shear.

Footing self weight:


To allow for the full self weight of the footing use a
S.Wt of concrete. To ignore, use 0.

Unreinforced:
For unreinforced, the designer should
consider providing Ast for M*.

Reinforcement (Bar cts/No/Area):


< 75 is the number of bars
≤ 600 is the bar centres in mm
> 600 is the actual mm²

Reinf't notation:
BUL - Bottom upper layer, BLL - Bottom lower layer

Ast.min - Cl 16.3.1
Ast.min = 0.19*(D/ds)²*f'ct.f/fsy*b*ds
f'ct.f = 0.6*√f'c (Cl 3.1.1.3)

Concrete bending capacity:


øMuo = ø*fsy*Ast*ds*[1-fsy*Ast/(2*α2*f'c*bw*ds)]
kuo = fsy*Ast/(α2*f'c*γ*ds*bw)

Shear øVu - Cl 8.2.5(ii):


Footing is considered to be a slab, therefore
shear ligs not required if V* ≤ øVuc

'.ur' values:
*.ur are values for unreinforced section.
Refer to AS 3600, Cl 12.1.1.1 & Section 15
øMuo.ur = ø*f'ct.f*Z (ø=0.6)
øVu.ur = ø*0.15*b*(D-50)*f'c¹′³ (ø=0.6)
øVp.ur = does not allow for moment transfer

Shear β values:
β1.L = 1.1*(1.6-do/1000) ≥ 0.8

Shear perimeter:
dom taken as the min. depth of tensile steel.

Unreinforced punching shear - Cl 15.4.3


øVp.ur1 = ø*0.1*u*(D-50)*(1+2/βh)*√f'c (ø=0.6)
øVp.ur2 = ø*0.2*u*(D-50)*√f'c (ø=0.6)
øVp.ur = min(øVp.ur1, øVp.ur2)

Depth for unreinforced - Cl 15.4.1


Depth considered as 50mm less than nominal depth