Geometry: (Eccentric Pad EP18) 1200mm long x 1200mm wide, 500mm depth
Loads: Rt = 18kN, Mox = 0.0kNm, Moy = 0.0kNm, Hx = 0.0kN, Hy = 0.0kN
Elastic: q.min = 13kPa & q.max = 13kPa < 200kPa allowable OK (0.06)
Plastic: N/A
Stability: Mox* = 0.0kNm, øMrx = 9.7kNm, Moy* = 0.0kNm, øMry = 9.7kNm OK (0.00,0.00)
Geometry
Width (W = x) = 1200 mm
Length (L = y) = 1200 mm (into page)
Depth (D) = 500 mm
Allowable Bp = 200 kPa
S.Wt. density (ρ) = 25.0 kN/m³
Method = E (E)lastic,(P)lastic
1200mm Wide (x 1200mm Long)
Loads (All loads working - Not ultimate) Designer to consider combinations when loads not permanant
X-Axis Y-Axis
Eccentricity (Ecc.x) = 0 mm Eccentricity (Ecc.y) = 0 mm
Outside Kern (Ecc.x > W/6) = 0 1=Yes Outside Kern (Ecc.y > L/6) = 0 1=Yes
yx = (W/2 - Ecc.x) = 600 mm yy = (L/2 - Ecc.y) = 600 mm
qx.min = -6*Rt*Ecc.x*/(L*W²) = 0.0 kPa qy.min = -6*Rt*Ecc.y*/(W*L²) = 0.0 kPa
qx.max = 6*Rt*Ecc.x*/(L*W²) = 0.0 kPa qy.max = 6*Rt*Ecc.y*/(W*L²) = 0.0 kPa
X-Axis Y-Axis
Eccentricity (Ecc.x) = 0 mm Eccentricity (Ecc.y) = 0 mm
Effective width (EW = 2*[W/2-Ecc.x]) = 1200 mm Effective length (EL = 2*[L/2-Ecc.y]) = 1200 mm
Step = 200 mm
Error = 187.5 kPa
Note:
P* is calculated using a load factor of 1.5
if the load type is not specified
and will be red.
Ulitimate Factor:
For determination of ultimate bearing (for pad design)